The exclamation point within an equilatereal triangle is intended to alert the user to the presence
of important operating and maintenance (servicing) instructions in the literature accompanying
the appliance.
Le point d’exclamation à l’intérieur d’un triangle équilatéral est prévu pour alerter l’utilisateur de la présence
d’instructions importantes dans la littérature accompagnant l’appareil en ce qui concerne l’opération et la
maintenance de cet appareil.
This lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous
voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk
of electric shock to persons.
Ce symbole d’éclair avec tête de flèche dans un triangle équilatéral est prévu pour alerter l’utilisateur de la
présence d’un «voltage dangereux» non-isolé à proximité de l’enceinte du produit qui pourrait être d’ampleur
suffisante pour présenter un risque de choque électrique.
DOC-Safety-5v0+UL60065-00-1v9 • February 2, 2022
Instructions pertaining to a risk of fire, electric shock, or injury to a person
Read Instructions:
The Owner’s Manual should be read and understood before operation of your unit. Please, save these instructions for future
reference and heed all warnings.
Cleaning:
Clean only with dry cloth.
Packaging:
Keep the box and packaging materials, in case the unit needs to be returned for service.
Wa
rning: To reduce the risk or fire or electric shock, do not expose this apparatus to rain or moisture. Do not use this apparatus near water!
Wa
rning: When using electric products, basic precautions should always be followed, including the following:
Power Sources
Your unit should be connected to a power source only of the voltage specified in the owners manual or as marked on the unit. This unit has a polarized
plug. Do not use with an extension cord or receptacle unless the plug can be fully inserted. Precautions should be taken so that the grounding scheme
on the unit is not defeated. An apparatus with CLASS I construction shall be connected to a Mains socket outlet with a protective earthing connection.
Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.
Hazards
Do not place this product on an unstable cart, stand, tripod, bracket or table. The product may fall, causing serious personal injury and serious
damage to the product. Use only with cart, stand, tripod, bracket, or table recommended by the manufacturer or sold with the product. Follow the
manufacturer’s instructions when installing the product and use mounting accessories recommended by the manufacturer. Only use
attachments/accessories specified by the manufacturer.
Equipment that is suspended overhead must use a secondary safeguard to prevent personal injury in the event the primary mounting mechanism
fails. Safety eyebolts attached to the equipment and galvanized steel wire can be used together to implement a failsafe mounting thus ensuring the
safety of the equipment and anyone positioned below the equipment.
Improper installation can result in bodily injury or death. If you are not qualified to attempt the installation get help from a professional structural rigger.
Note: Prolonged use of headphones at a high volume may cause health damage to your ears.
The apparatus should not be exposed to dripping or splashing water; no objects filled with liquids should be placed on the apparatus.
Terminals marked with the “lightning bolt” are hazardous live; the external wiring connected to these terminals require installation by an instructed
person or the use of ready made leads or cords.
Ensure that proper ventilation is provided around the appliance. Do not install near any heat sources such as radiators, heat registers, stoves, or
other apparatus (including amplifiers) that produce heat.
No naked flame sources, such as lighted candles, should be placed on the apparatus.
Power Cord
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type
plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your
outlet, consult an electrician for replacement of the obsolete outlet. The AC supply cord should be routed so that it is unlikely that it will be damaged.
Protect the power cord from being walked on or pinched particularly at plugs. If the AC supply cord is damaged DO NOT OPERATE THE UNIT. To
completely disconnect this apparatus from the AC Mains, disconnect the power supply cord plug from the AC receptacle. The mains plug of the power
supply cord shall remain readily operable.
Unplug this apparatus during lightning storms or when unused for long periods of time.
Service
The unit should be serviced only by qualified service personnel. Servicing is required when the apparatus has been damaged in any
way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus
has been exposed to rain or moisture, does not operate normally, requires battery pack replacement or has been dropped.
Disconnect power before servicing!
Instructions relatives au risque de feu, choc électrique, ou blessures aux personnes
Veuillez Lire le Manuel: Il contient des informations qui devraient êtres comprises avant l’opération de votre appareil. Conservez. Gardez S.V.P. ces
instructions pour consultations ultérieures et observez tous les avertissements.
Nettoyage: Nettoyez seulement avec le tissu sec.
Emballage: Conservez la boite au cas ou l’appareil devait être retourner pour réparation.
Avertissement: Pour réduire le risque de feu ou la décharge électrique, n'exposez pas cet appareil à la pluie ou à l'humidité. N’utilisez pas cet appareil
près de l’eau!
Attention: Lors de l’utilisation de produits électrique, assurez-vous d’adhérer à des précautions de bases incluant celle qui suivent:
Alimentation - L’appareil ne doit être branché qu’à une source d’alimentation correspondant au voltage spécifié dans le manuel ou tel qu’indiqué
sur l’appareil. Cet appareil est équipé d’une prise d’alimentation polarisée. Ne pas utiliser cet appareil avec un cordon de raccordement à moins qu’il soit
possible d’insérer complètement les trois lames. Des précautions doivent êtres prises afin d’eviter que le système de mise à la terre de l’appareil ne soit
désengagé. Un appareil construit selon les normes de CLASS I devrait être raccordé à une prise murale d’alimentation avec connexion intacte de mise à
la masse. Lorsqu’une prise de branchement ou un coupleur d'appareils est utilisée comme dispositif de débranchement, ce dispositif de débranchement
devra demeurer pleinement fonctionnel avec raccordement à la masse.
Risque - Ne pas placer cet appareil sur un chariot, un support, un trépied ou une table instables. L’appareil pourrait tomber et blesser quelqu’un ou subir
des dommages importants. Utiliser seulement un chariot, un support, un trépied ou une table recommandés par le fabricant ou vendus avec le produit. Suivre
les instructions du fabricant pour installer l’appareil et utiliser les accessoires recommandés par le fabricant. Utilisez seulement les attachements/accessoires
indiqués par le fabricant.
L'équipement suspendu au-dessus de la tête doit utiliser une protection secondaire pour éviter les blessures en cas de défaillance du mécanisme
de montage principal. Les boulons à œil de sécurité fixés à l'équipement et le fil d'acier galvanisé peuvent être utilisés ensemble pour mettre en
œuvre un montage à sécurité intégrée, assurant ainsi la sécurité de l'équipement et de toute personne placée sous l'équipement.
Une installation incorrecte peut entraîner des blessures corporelles ou la mort. Si vous n'êtes pas qualifié pour tenter l'installation, demandez l'aide
d'un gréeur structurel professionnel.
Remarque : L'utilisation prolongée d'écouteurs à un volume élevé peut nuire à la santé de vos oreilles.
Il convient de ne pas placer sur l’appareil de sources de flammes nues, telles que des bougies allumées.
L’appeil ne doit pas être exposé à des égouttements d’eau ou des éclaboussures et qu’aucun objet rempli de liquide tel que des vases ne doit être
placé sur l’appareil.
Assurez que lappareil est fourni de la propre ventilation. Ne procédez pas à l’installation près de source de chaleur tels que radiateurs, registre de
chaleur, fours ou autres appareils (incluant les amplificateurs) qui produisent de la chaleur.
Les dispositifs marqués d’une symbole “d’éclair” sont des parties dangereuses au toucher et que les câblages extérieurs connectés à ces
dispositifs de connection extérieure doivent être effectivés par un opérateur formé ou en utilisant des cordons déjà préparés.
Cordon d’Alimentation - Ne pas enlever le dispositif de sécurité sur la prise polarisée ou la prise avec tige de mise à la masse du cordon
d’alimentation. Une prise polarisée dispose de deux lames dont une plus large que l’autre. Une prise avec tige de mise à la masse dispose de deux lames
en plus d’une troisième tige qui connecte à la masse. La lame plus large ou la tige de mise à la masse est prévu pour votre sécurité. La prise murale est
désuète si elle n’est pas conçue pour accepter ce type de prise avec dispositif de sécurité. Dans ce cas, contactez un électricien pour faire remplacer la
prise murale. Évitez d’endommager le cordon d’alimentation. Protégez le cordon d’alimentation. Assurez-vous qu’on ne marche pas dessus et qu’on ne le
pince pas en particulier aux prises. N’UTILISEZ PAS L’APPAREIL si le cordon d’alimentation est endommagé. Pour débrancher comp
lètement cet appareil
de l’alimentation CA principale, déconnectez le cordon d’alimentation de la prise d’alimentation murale. Le cordon d’alimentation du bloc d’alimentation de
l’appareil doit demeurer pleinement fonctionnel.
Débranchez cet appareil durant les orages ou si inutilisé pendant de longues périodes.
Service - L'appareil ne doit être entretenu que par un personnel de service qualifié. Une réparation est nécessaire lorsque l'appareil a été endommagé de
quelque manière que ce soit, comme le cordon d'alimentation ou la fiche est endommagé, du liquide a été renversé ou des objets sont tombés dans l'appareil,
l'appareil a été exposé à la pluie ou à l'humidité, ne fonctionne pas normalement , nécessite le remplacement de la batterie ou est tombé. Débranchez
l'alimentation avant l'entretien!
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
FOLLOW ALL INSTRUCTIONS SUIVEZ TOUTES LES INSTRUCTIONS
AVIS: AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE, N’ENLEVEZ PAS LE COUVERT (OU LE PANNEAU
ARRIERE) NE CONTIENT AUCUNE PIECE REPARABLE PAR L’UTILISATEUR. CONSULTEZ UN TECHNICIEN
QUALIFIE POUR L’ENTRETIENT CE PRODUIT EST POUR L’USAGE À L’INTÉREUR SEULEMENT. LES PACKS
BATTERIES INSTALLÉS NE DOIVENT PAS ÊTRE EXPOSÉS À UNE CHALEUR EXCESSIVE TELLE QUE LE
ENSOLEILLEMENT, LE FEU OU SIMILAIRES.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL. THIS DEVICE IS FOR INDOOR USE ONLY!
INSTALLED BATTERY PACKS SHALL NOT BE EXPOSED TO EXCESSIVE HEAT
SUCH AS SUNSHINE, FIRE OR THE LIKE.
SEPARATE
COLLECTION
WEEE
DO NOT
PUSH OR PULL
CAUTION: OVERHEAD LOAD
ATTENTION: CHARGE AÉRIENNE
The Lightning Flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated
"dangerous voltage" within the product enclosure that may be of sufficient magnitude to constitute a risk of shock to persons
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance
(servicing) instructions in the literature accompanying the product
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water
.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacture
r’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) th
at produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug.
A polarized plug has two blades with one wider than the other. A grounding
type plug has two blades and a third grounding prong.
The wide blade or the third prongs are provided for your safety. If the provided plug does not fit
into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where
they exit from
t
he apparatus.
11
. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacture
r, or sold with the apparatus. When a cart is used, use caution when
moving the cart/apparatus combination to avoid injury from tip-over
.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any wa
y, such as power-supply
cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to
rain or moisture, does not
operate normally
, or has been dropped.
W
ARNING:
To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture and objects filled with liquids, such as vases, should not be
placed on this apparatus.
To completely disconnect this apparatus from the ac mains, disconnect the power supply cord plug from the ac receptacle.
The mains plug of the power supply cord or appliance coupler shall remain readily accessible.
Le symbole représentant un éclair avec une flèche à l’intérieur d’un triangle équilatéral est utilisé pour prévenir l’utilisate
ur de la
présence d’une tension électrique dangereuse non isolée à l’intérieur de l’appareil. Cette tension est d’un niveau suffisamment
élevé pour représenter un risque d’électrocution
Le symbole représentant un point d’exclamation à l’intérieur d’un triangle équilatéral, signale à l’utilisateur la présence d’instructions importantes
relatives au fonctionnement et à l’entretien de l’appareil dans cette notice d’installation
1. Lisez ces instructions.
2. Conservez ces instructions.
3. Respecter tous les avertissements.
4. Suivez toutes les instructions.
5. N'utilisez pas l'appareil près de l'eau.
6. Nettoyer uniquement avec chiffon sec.
7. Ne bloquez pas les ouvertures de ventilation. Installer en suivant les instructions du fabricant.
8. Ne pas installer près des sources de chaleur telles que radiateurs, bouches de chaleur, four ou autres appareils (y compris les amplificateurs)
produisant de la chaleur.
9. N'annulez pas l'objectif sécuritaire de la fiche polarisée ou de la tige de mise à la terre. Une fiche polarisée possède deux lames avec une plus large
que l'autre. Une prise avec mise à la terre possède deux lames et une troisième tige. La lame large ou la troisième tige sont fournis pour votre sécurité.
Si la fiche n'entre pas dans votre prise, consultez un électricien pour remplacer la prise obsolète.
10. Protéger le cordon d'alimentation des piétinements ou pincements en particulier près des fiches, des prises de courant et au point de
sortie de l'appareil.
11. Utilisez uniquement les accessoires spécifiés par le fabricant.
12. Utiliser uniquement avec un charriot, stand, trépied ou une table spécifiée par le fabricant, ou vendus avec l'appareil.
13. Débranchez l'appareil durant un orage ou lorsqu'il reste inutilisé pendant de longues périodes de temps.
14. Confiez toute réparation à un technicien qualifié. Une réparation est nécessaire lorsque l'appareil a été endommagé de quelque façon que ce soit;
comme lorsque le cordon d'alimentation ou la fiche est endommagé, lorsque du liquide a été renversé ou des objets sont tombés à l'intérieur, lorsque
l'appareil a été exposé à la pluie ou l'humidité, ne fonctionne pas normalement, ou est tombé.
AVERTISSEMENT:
• Pour réduire les risques d'incendie ou de choc électrique, ne pas exposer cet appareil à la pluie ou à l'humidité et ne placez pas d’objets contenant
des liquides, tels que des vases, sur l’appareil.
• Pour isoler totalement cet appareil de l'alimentation secteur, débranchez totalement son cordon d'alimentation du réceptacle CA.
• La prise du cordon d’alimentation ou du prolongateur, si vous en utilisez un comme dispositif de débranchement, doit rester facilement accessible
CAUTION
TO PREVENT ELECTRIC SHOCK HAZARD,
DO NOT CONNECT TO MAINS POWER SUPPLY
WHILE GRILLE IS REMOVED.
AVIS
POUR PRÉVENIR LES RISQUES D'ÉLECTROCUTION,
NE PAS RACCORDER A L’ALIMENTATION ÉLECTRIQUE ALORS
QUE LA GRILLE EST RETIRÉE.
The DO NOT STACK symbol is intended to alert the user that the product shall not be
vertically stacked because of the nature of the product.
La symbole NE PAS EMPILER est pour alerter l'utilisateur que le produit ne doit pas être
empilé verticalement en raison de la nature du produit.NOT TO BE SERVICED
BY USERS
CAUTION: HOT SURFACE
ATTENTION: SURFACE CHAUDE
IEC 60417-5041
Important Safety Instructions - English / Français
ii
Cover .................................................................................. a
Important Safety Instructions - English / Français ................i
EMC Declaration TYPE B - English / Français ...................ii
Table of Contents .................................................................ii
Synergy SA102 Powered Speaker ..................................... 1
Cabinet Features ............................................................. 1
Electronic Features ........................................................ 1
1. Power Switch and Indicator ........................................ 1
2. PowerCON TRUE AC Loop Thru ............................... 1
3. Input Jack ................................................................... 1
4. Dual Link Outputs ........................................................ 1
5. SA102 Level Control ................................................... 1
6. Mode Switch (Sub/No Sub) ........................................ 1
7. HF (High Frequency) Adjust Selector ......................... 1
8. Clip and Limit Indicators .............................................. 2
Enceinte Ampliée Synergy SA102 .................................... 3
Caractéristiques de l’Enceinte ......................................... 3
Caractéristiques Électroniques ....................................... 3
1. Interrupteur et Indicateur d’Alimentation .................... 3
2. PowerCON TRUE AC Loop Thru. .............................. 3
3. Prise d’Entrée ............................................................. 3
4. Sorties Dual Link ......................................................... 3
5. Commande de Niveau SA102 ..................................... 3
6. Commutateur de Mode (Sub/No Sub) ........................ 4
7. Sélecteur de Réglage HF (Haute Fréquence) ............ 4
8. Indicateurs Clip et Limit ............................................... 4
Specications - English ...................................................... 5
Spécications - Français .................................................... 6
SYNERGY-Convenience-Receptacle ................................. 7
Recéptacle de Commodité SYNERGY ............................... 8
Block Diagram .................................................................... 9
Warranty - English / Français ........................................... 10
Rear Page .........................................................................11
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense.
Cet équipement a été testé et déclaré conforme aux limites d'un appareil numérique de
classe A, conformément à la partie 15 des règles de la FCC. Ces limites sont conçues
pour fournir une protection raisonnable contre les interférences nuisibles lorsque
l'équipement est utilisé dans un environnement commercial. Cet équipement génère,
utilise et peut émettre de l'énergie de radiofréquence et, s'il n'est pas installé et utilisé
conformément au manuel d'instructions, peut causer des interférences nuisibles aux
communications radio. L'utilisation de cet équipement dans une zone résidentielle est
susceptible de provoquer des interférences nuisibles, auquel cas l'utilisateur devra
corriger les interférences à ses propres frais.
The DO NOT STACK symbol is intended to
alert the user that the product shall not be
vertically stacked because of the nature of the pr
oduct.
La symbole NE PAS EMPILER est pour alerter
l'utilisateur que le produit ne doit pas être empilé
verticalement en raison de la nature du produit.
EMC Declaration - English / Français
Table of Contents
1
Synergy SA102 Powered Speaker
Thank you for choosing Yorkville’s Synergy SA102 arrayable speaker, the pinnacle of clarity and output in a
fully expandable speaker system. The SA102 excels in sound reinforcement applications where a line array is
desired but cannot be easily accommodated. Used alone or in multiples with the matching SA115 subwoofers,
the SA102 is designed to deliver reliable, high quality audio at a professional level.
Cabinet Features
The SA102 is constructed of high strength multiply birch plywood for ultimate durability. At the heart of the
SA102 is a Paraline lens loaded with a coaxial compression driver along with a 10-inch woofer mounted on a
30°H x 45°V constant directivity horn. Paraline technology was rst developed for Yorkville’s agship VTC Pro
Audio Elevation series line array. By channeling the sound waves along equidistant paths, the Paraline lens
converts the point source compression driver into a line source with constant phase and amplitude. The result
is a completely balanced sound eld and coverage pattern across the cabinet’s horizontal and vertical planes.
The unique design of the SA102 allows the cabinets to be placed side by side without interference.
Cabinets can be placed together to cover as wide a pattern as desired, including 360 degrees, without
any lobbing or interference patterns.
Electronic Features
Innovative DSP processing is used to drive the 900-watt Class-D woofer amplier and the three-tier 300-watt horn
amplier. An active crossover for the ampliers ensures that the woofer and horn operate optimally; meanwhile,
separate non-defeatable limiters protect those drivers from excessive peaks and over-powering. The drivers
themselves are sourced from the world’s premier manufacturers offering an extended lifetime of smooth, powerful
performance. We are condent you will nd the SA102 a worthy mainstay for all of your sound application needs.
1. Power Switch and Indicator
The green power LED illuminates when the power switch is turned to the On position and AC voltage is supplied.
2. PowerCON TRUE AC Loop Thru
As a standard, the AC inlet on the SA102 accepts locking PowerCON TRUE power cords. There is also an AC
outlet that can be used to loop power through to other cabinets in your array using a male to female PowerCON
TRUE looping power cord. Check with your local Yorkville dealer for availability of these accessory cords.
IMPORTANT: DO NOT EXCEED THE CURRENT RATING OF THE POWER and ACCESSORY CORDS.
PLEASE READ THE SECTION OF THIS MANUAL CALLED CASCADE INSTALLATION
3. Input Jack
This female-XLR accepts line level XLR microphone cables. For best noise reduction use balanced sources.
4. Dual Link Outputs
These XLR male connectors can be used with a standard XLR cable to daisy-chain up to 20 SA102 or SA115
cabinets without signal degradation. Simply loop from one cabinet’s Link jack to the next cabinets Input jack.
5. SA102 Level Control
This control adjusts the volume level of the SA102 relative to the input signal level. Mixers and other audio sources
connected to the SA102 tend to have different output voltages, which mean the level control on the SA102 is used
to ne tune the cabinet’s volume relative to the mixer settings. It is perfectly acceptable to set the SA102 Level
above or below the center 0 dB setting. When arraying multiple cabinets, it may be desirable to reduce the volume
of some cabinets to better cover the audience. (ex. The outer box of a cluster may be against a wall)
6. Mode Switch (Sub/No Sub)
This switch allows the user to congure the SA102 to be used with or without a subwoofer. In “No Sub” mode,
the cabinet’s internal high-pass (low-cut) lter is set to 50 Hz. When using the SA102 with a subwoofer, such as
the SA115, depress the button to set the internal high-pass lter to align perfectly with the subwoofer.
7. HF (High Frequency) Adjust Selector
The HF Adjust switch is used to set the relative high frequency level of the SA102. If you are assembling multiple SA102
cabinets into an array, you may notice an increase in bass and a lack of treble. This is due to low frequency coupling between
the cabinets of the low frequency drivers. Setting this control to the number of cabinets in the array will insure at response
from the system. As the number of cabinets increases the high frequency output will be correspondingly increased.
The HF switch can also be used in applications where the loudspeakers are situated far from the audience.
The increase of treble will help overcome the natural loss of high frequency due to traveling a greater distance.
2
OUTPUT
INPUT
OUTPUT
ALL CONNECTED
IN PARALLEL
Clip
Limit
Activity
LEVEL HF ADJUST
3
1
4-6
2
Power
SUB
No Sub
Off 8
-
12
-
24
4
6
-
62
-
21
0
dB NUMBER OF SA102
CABINETS PER SIDE
8. Clip and Limit Indicators
The Clip and Limit LED indicators illuminate to guide the user to proper operating levels. Illumination of the yellow
Limit LED indicates that a level has been reached where the SA102 limiters are reducing the signal internally to
prevent damage or distortion. It also indicates that further increases in input level or increasing the SA102 Level
control position will not appreciably increase acoustic output. The red Clip LED indicates that the input level is ex-
cessive and further increases in level will cause severe distortion. This happens at very high input signal levels in
excess of 13V peak. The input signal should be reduced at the source until Clip activity ceases.
3
Enceinte Ampliée Synergy SA102
Merci d’avoir choisi l’enceinte Synergy SA102 de Yorkville. Elle représente le summum de la clarté et du
rendement dans un système d’enceintes entièrement extensible. La SA102 excelle dans les applications
de renforcement sonore où un line array est souhaité mais ne peut être facilement installé. Utilisée seule
ou avec les subwoofers SA115 correspondants, la SA102 est conçue pour fournir un son able et de haute
qualité à un niveau professionnel.
Caractéristiques de l’Enceinte
Le SA102 est construit en contreplaqué de bouleau multi-plis haute résistance pour une durabilité ultime. Au
cœur de la SA102 se trouve une lentille Paraline avec haut-parleur à compression coaxial ainsi qu’un woofer
de 10 pouces monté sur un pavillon à directivité constante de 30°H x 45°V. La technologie Paraline a d’abord
été développée pour le euron de la marque Yorkville, la série VTC Pro Audio Elevation. En canalisant les
ondes sonores le long de voies équidistantes, la lentille Paraline convertit le haut-parleur à compression à
source focale en une source linéaire à phase et amplitude constantes. Le résultat est un champ sonore et un
modèle de couverture complètement équilibrés sur les plans horizontal et vertical de l’enceinte.
La conception unique de la SA102 permet de placer les enceintes côte à côte sans interférence. Les en-
ceintes peuvent être placées ensemble pour couvrir un motif aussi large que souhaité, y compris 360 degrés,
sans aucun lober ou motif d’interférence.
Caractéristiques Électroniques
Un traitement de signal numérique innovant est utilisé pour alimenter l’amplicateur de 900 watts de classe
D pour le woofer et l’amplicateur à trois rangées de 300 watts pour le pavillon. Un ltre actif pour les ampli-
cateurs garantit le fonctionnement optimal du woofer et du pavillon ; parallèlement, des limiteurs séparés qui
ne peuvent être désacitvés protègent ces haut-parleurs contre les crêtes excessives et la surpuissance. Les
haut-parleurs eux-mêmes proviennent des meilleurs fabricants au monde, ce qui garantit une durée de vie pro-
longée et des performances constantes et puissantes. Nous sommes convaincus que le SA102 sera un outil
de choix pour tous vos besoins en matière d’applications sonores.
1. Interrupteur et Indicateur d’Alimentation
Le voyant vert d’alimentation s’allume lorsque l’interrupteur d’alimentation est en position ON et que la ten-
sion CA est appliquée.
2. PowerCON TRUE AC Loop Thru.
En standard, l’entrée CA de la SA102 accepte les cordons d’alimentation PowerCON TRUE à verrouillage. Il y
a également une prise CA qui peut être utilisée pour boucler l’alimentation vers d’autres enceintes dans votre
réseau en utilisant un cordon d’alimentation PowerCON TRUE mâle à femelle. Vériez auprès de votre reven-
deur Yorkville local la disponibilité de ces cordons accessoires.
IMPORTANT : NE PAS DÉPASSER LE COURANT MAXIMAL DES CORDONS D’ALIMENTATION ET
DES ACCESSOIRES. VEUILLEZ LIRE LA SECTION DE CE MANUEL INTITULÉE “INSTALLATION EN
CASCADE”.
3. Prise d’Entrée
Cette femelle-XLR accepte les câbles de microphone XLR de niveau ligne. Pour une meilleure réduction du
bruit, utilisez des sources équilibrées.
4. Sorties Dual Link
Ces connecteurs mâles XLR peuvent être utilisés avec un câble XLR standard pour relier en chaine jusqu’à 20
enceintes SA102 ou SA115 sans dégradation du signal. Il suft de relier la prise Link d’une enceinte à la prise
Input de l’enceinte suivante.
5. Commande de Niveau SA102
Cette commande permet de régler le niveau de volume du SA102 par rapport au niveau du signal d’entrée. Les
mixeurs et autres sources audio connectés au SA102 ont tendance à avoir des tensions de sortie différentes, ce
qui signie que la commande de niveau sur la SA102 est utilisé pour afner le volume du cabinet par rapport aux
réglages du mixeur. Il est parfaitement acceptable de régler le niveau du SA102 au-dessus ou au-dessous du
réglage central de 0 dB. Avec un système de type Line Array, il peut être souhaitable de réduire le volume de cer-
taines enceintes pour mieux couvrir l’audience. (ex. le caisson extérieur d’un cluster peut être contre un mur)
4
6. Commutateur de Mode (Sub/No Sub)
Ce commutateur permet à l’utilisateur de congurer le SA102 pour être utilisé avec ou sans caisson de
basse. En mode “No Sub”, le ltre passe-haut (coupe-bas) interne du caisson est réglé sur 50 Hz. Lorsque
vous utilisez le SA102 avec un caisson de basse, tel que le SA115, appuyez sur le bouton pour régler le ltre
passe-haut interne an qu’il s’aligne parfaitement avec le caisson de basse.
7. Sélecteur de Réglage HF (Haute Fréquence)
Le commutateur HF Adjust est utilisé pour régler le niveau relatif des hautes fréquences du SA102. Si vous
assemblez plusieurs enceintes SA102 en un Array, vous pouvez remarquer une augmentation des basses
et un manque d’aigus. Ceci est dû au couplage basse fréquence entre les cabinets des haut-parleurs
basse fréquence. En réglant cette commande sur le nombre de caissons dans l’ensemble, vous obtiendrez
une courbe de réponse plate pour le système. Lorsque le nombre de caissons augmente, la sortie haute
fréquence augmente en conséquence.
Le commutateur HF Adjust peut également être utilisé dans les applications où les haut-parleurs sont
situés loin du public. L’augmentation des aigus aidera à surmonter la perte naturelle des hautes fréquences
due au déplacement sur une plus grande distance.
8. Indicateurs Clip et Limit
Les indicateurs DEL Clip et Limit s’allument pour guider l’utilisateur vers les niveaux de fonctionnement ap-
propriés. L’illumination de la DEL jaune de limite indique qu’un niveau a été atteint où les limiteurs SA102
réduisent le signal en interne pour éviter tout dommage ou distorsion. Elle indique également que toute
augmentation supplémentaire du niveau d’entrée ou de la position de la commande de niveau du SA102
n’augmentera pas sensiblement la sortie acoustique. La DEL rouge Clip indique que le niveau d’entrée est
excessif et que toute augmentation supplémentaire du niveau entraînera une distorsion importante. Cela
se produit à des niveaux de signal d’entrée très élevés, supérieurs à 13V crête. Le signal d’entrée doit être
réduit à la source jusqu’à ce que l’activité de la DEL clip cesse.
OUTPUT
INPUT
OUTPUT
ALL CONNECTED
IN PARALLEL
Clip
Limit
Activity
LEVEL HF ADJUST
3
1
4-6
2
Power
SUB
No Sub
Off 8
-
12
-
24
4
6
-
62
-
21
0
dB NUMBER OF SA102
CABINETS PER SIDE
5
System Type Active Full-Range Powered Speaker
Active or PassiveActive
Program Power (watts)1200 watts Program (2400 watts Peak)
BiampableBiamp
Measured Max SPL (C-Weighted, Max Hold)127 dB Continous 133 dB Peak
Frequency Response (Hz +/- 3dB) 60Hz-18k
Modèle de projection 30x45 Asymmetrical (7 Haut, 38 Bas)
Crossover Frequency (Hz) 750Hz
Cabinet ConfigurationPatented Synergy Horn and Paraline Lens Technology
Driver Configuration1x10-inches LF Woofer, 1xHF Compression Driver
HF Driver(s)4-inches Diaphragm/Voice Coil, Neo
HF Program Power (watts)120 watts Program, 240 watts Peak
HF Impedance (ohms) 8 ohm Load
HF Protection Peak and Average Limiting
LF Driver(s)1x10-inches Neo Woofer with 3-inches Voice Coil
LF Impedance (ohms) 2 ohm Load
LF Protection Excursion, RMS
HF Power Amplifier (watts)300 watts Program, 500 watts Peak
HF Amplifier Type 3-Tier Class H
LF Power Amplifier (watts)900 watts Program, 1600 watts Peak
LF Amplifier Type Class D
Cooling Scheme Convection
Power CableRemovable Locking Powercon True Input and Loop Thru Output
Power Switch Yes
Power Consumption200VA/320VA Max
Inputs 1 XLR, 2 x XLR Loop
Input Sensitivity (Vrms Sine)Line in 1.4 at center, 0.56 at max
Level Controls Volume
EQ Controls HF Boost select, Fullrange/Sub switch
LED Indicators Power, Limit, Clip
Enclosure MaterialsMultiply 15mm Birch Plywood
Standard Rigging Hardware 1/4-20 Eyebolts (4 Top, 4 Bottom)
Stacking FeatureInterlocking UHMW Feet (Top and Bottom)
Covering / Finish Paint
Dimensions (DWH xbackW, inches)21.250 x 17.375 x 22.750 x 6.750
Dimensions (DWH xbackW, cm)54 x 45 x 58 x 17
Weight (lbs/kg) 69/31.3
* Specifications subject to change without notice
Specifications
Specications - English
6
Type de systèmeHaut-parleur actif à large bande
Actif ou passifActif
Puissance du programme (watts) 1200 watts en programme (2400 watts en crête)
BiampableBi-amplification
NPA maximum mesuré (pondéré C, maintien maximum) 127 dB en continu 133 dB en crête
Réponse en fréquence (Hz +/- 3dB) 60Hz-18k
Modèle de projection 30x45 Asymétrique (7 Up, 38 Down)
Fréquence de coupure (Hz) 750 Hz
Configuration de l'enceinte Technologie brevetée du pavillon Synergy et de la
lentille Paraline
Configuration des haut-parleurs1 haut-parleur de graves de 10 pouces, 1 haut-parleur à
compression HF
Pilote(s) HF Bobine/Diaphragme de 4 pouces, Neo
Puissance du programme HF (watts)Programme 120 watts, crête 240 watts
Impédance HF (ohms) Charge de 8 ohms
Protection HF Limitation de crête et de moyenne
Pilote(s) BF 1 haut-parleur de graves Neo de 10 pouces avec bobine
acoustique de 3 pouces
Impédance LF (ohms) Charge de 2 ohms
Protection BF Excursion, RMS
Amplificateur de puissance HF (watts)300 watts en programme, 500 watts en crête
Type d'amplificateur HF Classe H à 3 rangées
Amplificateur de puissance BF (watts)900 watts en programme, 1600 watts en pointe
Type d'amplificateur BF Classe D
Schéma de refroidissement Convection
Câble d'alimentation Entrée Powercon True et sortie Loop Thru verrouillables
et amovibles
Commutateur d'alimentation Oui
Consommation d'énergie 200VA/320VA Max
Entrées1 XLR, 2 x XLR en boucle
Sensibilité d'entrée (Vrms Sinus) Entrée ligne 1,4 au centre, 0,56 au maximum
Commandes de niveau Volume
Commandes d'égalisationSélection HF Boost, commutateur Pleine Bande / Sub
Indicateurs DELAlimentation, Limit, Clip
Matériaux du boîtierContreplaqué multicouche de bouleau 15 mm
Matériel de montage standard Boulons à œil 1/4-20 (4 en haut, 4 en bas)
Fonction d'empilage Pieds UHMW emboîtables (haut et bas)
Retement / Finition Peinture
Dimensions (PLH x arrièreL, pouces) 21.250 x 17.375 x 22.750 x 6.750
Dimensions (PLH x arrièreL, cm)54 x 45 x 58 x 17
Poids (livres/kg)69/31.3
* Spécifications sujettes à modification sans préavis
Spécifications
Spécications - Français
SYNERGY-Convenience-Receptacle-(Cascade-Installation)-en-00-2v5.docx June 23, 2022
Yorkville Synergy Convenience Receptacle Installation (Cascade Installation)
RATED CURRENT
Table 1 - SYNERGY RATED CURRENT
a The LINE CURRENT LIMIT SWITCH allows the user to limit the maximum continuous current consumption to reduced
values as shown.
Tech Support: If you have any questions concerning your SYNERGY equipment don’t hesitate to contact synergy@yorkville.com
ELECTRICAL SAFETY
It is always important to connect all sound reinforcement equipment to ac mains supply circuits that have proper electrical
safety grounds. Never break off the Earth Ground pin from a 3-prong plug. This pin provides personal protection from
electrical shock and protection of the equipment from lightning strikes and electrostatic buildup. It is also required for EMC
shielding. Replace the plug if the Earth Ground pin is missing.
1. Always connect the equipment to a circuit with a suitable electrical ground.
2. Do not overload the power cords and convenience outlets.
3. Always inspect the cords and plugs before use. Do not use outlets or cords that have exposed conductors, are worn or
damaged. Replace electrical cords that have worn or damaged insulation and remember to pull the plug not the cord to
prevent damage to the cord. Only replace with the equivalent heavy-duty cord supplied by the manufacturer.
4. The AC supply cord should be routed so that it is unlikely that it will be damaged. Protect the power cord from being
walked on or pinched. If the AC supply cord is damaged DO NOT OPERATE THE UNIT. To completely disconnect this
apparatus from the AC Mains, disconnect the power supply cord plug from the AC receptacle. The mains plug of the
power supply cord shall remain readily accessible. Unplug the apparatus during lightning storms or when unused for
long periods of time. Route cords away from traffic to avoid tripping hazards and unnecessary wear on the power cord.
5. Never Break Off the Third Prong on a Plug. Replace broken 3-prong plugs and make sure the third prong is properly grounded.
6. Keep line cords away from heat, water and oil. They can damage the insulation and create a shock hazard.
7. Do not tie cords in tight knots. Knots can cause short circuits and shocks. Loop the cords or use a twist lock plug.
MAINS VOLTAGE MODEL
RATED
CURRENT
(Arms)
LINE CURRENT a
LIMIT SWITCH
(Arms)
MAX
80%
60%
120V 60 Hz
(NORTH AMERICA)
1.0
2.5
3.0
11.0
11.0
8.0
6.0
10.2
10.2
10.2
8.1
230V 50 Hz
(EUROPE)
0.5
1.5
6.3
6.3
4.0
3.0
SYNERGY-Convenience-Receptacle
SYNERGY-Convenience-Receptacle-(Cascade-Installation)-fr-00-2v5.docx - June 24, 2022
Installation d'Un Réceptacle de Commodité Yorkville Synergy (Installation en Cascade)
COURANT NOMINAL
Tableau 1 - COURANT NOMINAL DE SYNERGIE
a Le commutateur LINE CURRENT LIMIT permet à l'utilisateur de limiter la consommation maximale de courant continu à des valeurs
réduites comme indiqué.
Support technique : Si vous avez des questions concernant votre équipement SYNERGY, n'hésitez pas à contacter [email protected]m.
SÉCURITÉ RELATIVE À L'ÉLECTRICITÉ
Il est toujours important de connecter tous les équipements de sonorisation à des circuits d'alimentation secteur dotés de mises à la
terre de sécurité électrique appropriées. Ne coupez jamais la broche de mise à la terre d'une fiche à trois broches. Cette broche assure
la protection des personnes contre les chocs électriques et la protection de l'équipement contre la foudre et l'accumulation d'électricité
statique. Elle est également nécessaire pour le blindage CEM. Remplacez la fiche si la broche de mise à la terre est absente.
1. Connectez toujours l'équipement à un circuit avec une mise à la terre électrique appropriée.
2. Ne surchargez pas les cordons d'alimentation et les prises de courant.
3. Inspectez toujours les cordons et les fiches avant de les utiliser. N'utilisez pas de prises ou de cordons dont les conducteurs sont
exposés, qui sont usés ou endommagés. Remplacez les cordons électriques dont l'isolation est usée ou endommagée et n'oubliez
pas de tirer sur la fiche et non sur le cordon pour éviter d'endommager ce dernier. Ne remplacez le cordon électrique que par un
cordon équivalent à usage intensif fourni par le fabricant.
4. Le cordon d'alimentation CA doit être acheminé de manière qu'il soit peu probable qu'il soit endommagé. Protégez le cordon
d'alimentation pour qu'il ne soit pas piétiné ou pincé. Si le cordon d'alimentation CA est endommagé, NE PAS FAIRE
FONCTIONNER L'APPAREIL. Pour déconnecter complètement cet appareil du secteur, débranchez la fiche du cordon
d'alimentation de la prise de courant. La fiche du cordon d'alimentation doit rester facilement accessible. Débranchez l'appareil
pendant les orages ou lorsqu'il n'est pas utilisé pendant de longues périodes. Acheminez les cordons à l'écart de la circulation pour
éviter les risques de trébuchement et l'usure inutile du cordon d'alimentation.
5. Ne cassez jamais la troisième broche d'une fiche. Remplacez les fiches à trois broches cassées et assurez-vous que la troisième broche est
correctement mise à la terre.
6. Gardez les cordons de ligne à l'écart de la chaleur, de l'eau et de l'huile. Ils peuvent endommager l'isolation et créer un risque de choc.
7. Ne faites pas de nœuds serrés avec les cordons. Les nœuds peuvent provoquer des courts-circuits et des chocs. Faites des
boucles avec les cordons ou utilisez une fiche à verrouillage par torsion.
TENSION PRINCIPALE MODÈLE
COURANT
NOMINAL
(Armes)
COURANT DE LIGNE a
COMMUTATEUR DE LIMITEUR
(Armes)
MAX
80%
60%
120V 60 Hz
(AMÉRIQUE DU NORD)
SA102
1.0
SA153
2.5
SA115S
3.0
SA221S
11.0
11.0
8.0
6.0
SA315S
10.2
10.2
10.2
8.1
230V 50 Hz
(EUROPE)
SA102
0.5
SA153
1.5
SA221SCE
6.3
6.3
4.0
3.0
Recéptacle de Commodité SYNERGY
9
DAC
Microcontroller
Sub
DSP
ADC
block-diagram-SYNERGY-SA102-00-1v0
1
3
2
1
3
2
1
3
2
Input
Output
Output
ClipLimitAct
Level HP Adjust
HF
AMP
LF
AMP
Block Diagram SA102
DESIGNED & MANUFACTURED BY YORKVILLE SOUND
Block Diagram
10
Unlimited Warranty
Yorkville's two and ten-year unlimited warranty on this product is transferable
and does not require registration with Yorkville Sound or your dealer. If this
product should fail for any reason within two years of the original purchase
date (ten years for the wooden enclosure), simply return it to your Yorkville
dealer with original proof of purchase and it will be repaired free of charge.
This includes all Yorkville products, except for the YSM Series studio
monitors, Coliseum Mini Series and TX Series Loudspeakers.
Freight charges, consequential damages, weather damage, damage as a result
of improper installation, damages due to exposure to extreme humidity, accident
or natural disaster are excluded under the terms of this warranty. Warranty does
not cover consumables such as vacuum tubes or par bulbs. See your Yorkville
dealer for more details. Warranty valid only in Canada and the United States.
Garantie Illimitée
La garantie illimitée de deux et dix ans de ce produit est transférable. Il n`est pas
nécessaire de faire enregistrer votre nom auprès de Yorkville Sound ou de votre
détaillant. Si, pour une raison quelconque, ce produit devient défectueux durant
les deux années qui suivent la date d`achat initial (dix ans pour l`ébénisterie),
retournez-le simplement à votre détaillant Yorkville avec la preuve d`achat original
et il sera réparé gratuitement. Ceci inclus tous les produits Yorkville à l`exception
de la série de moniteurs de studio YSM, la mini série Coliseum et de la série TX.
Les frais de port et de manutention ainsi que les dommages indirects ou
dommages causés par désastres naturels, extrême humidité ou mauvaise
installation ne sont pas couverts par cette garantie. Cette garantie ne couvre
pas les produits consommables tels que lampe d`amplificateur ou ampoules
"PAR". Voir votre détaillant Yorkville pour plus de détails. Cette garantie n’est
valide qu’au Canada et aux États Unis d’Amérique.
www.yorkville.com
www.yorkville.com
REAL Gear.
REAL People.
REAL Gear.
REAL People.
Yorkville Sound
550 Granite Court
Pickering, Ontario
L1W-3Y8 CANADA
Canada
Voice: (905) 837-8481
Fax: (905) 837-8746
Yorkville Sound Inc.
4625 Witmer Industrial Estate
Niagara Falls, New Yo rk
14305 USA
U.S.A.
Voice: (716) 297-2920
Fax: (716) 297-3689
Printed in Canada
Two & Ten Year Warranty
Two
&
&
Ten
Warranty - English / Français
U.S.A.
Yorkville Sound Inc.
4625 Witmer Industrial Estate
Niagara Falls, New York
14305, USA
Voice: 716-297-2920
Fax: 716-297-3689
WORLD HEADQUARTERS
CANADA
Yorkville Sound Limited
550 Granite Court
Pickering, Ontario
L1W 3Y8 CANADA
Voice: 905-837-8481
Fax: 905-837-8746
Manual-Owners-SYNERGY-SA102-00-1v3 • August 29, 2022
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

YORKVILLE SA102 Le manuel du propriétaire

Catégorie
Équipement musical supplémentaire
Taper
Le manuel du propriétaire

dans d''autres langues