YORKVILLE SA115S Le manuel du propriétaire

Catégorie
Équipement musical supplémentaire
Taper
Le manuel du propriétaire
OWNER’S MANUAL
MANUEL DE L’UTILISATEUR
SA115S
The exclamation point within an equilatereal triangle is intended to alert the
user to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
Le point d’exclamation à l’intérieur d’un triangle équilatéral est prévu pour alerter
l’utilisateur de la présence d’instructions importantes dans la littérature accompagnant
l’appareil en ce qui concerne l’opération et la maintenance de cet appareil.
This lightning flash with arrowhead symbol, within
an equilateral triangle, is intended to alert the user to the presence of
uninsulated dangerous voltage” within the product’s enclosure that may be
of sufficient magnitude to constitute a risk of electric shock to persons.
Ce symbole d’éclair avec tête de flèche dans un triangle équilatéral est prévu pour alerter
l’utilisateur de la présence d’un «voltage dangereux» non-isolé à proximité de l’enceinte du
produit qui pourrait être d’ampleur suffisante pour présenter un risque de choque électrique.
DOC-Safety-5v0+UL60065-00-1v8 • February 24, 2020
Instructions pertaining to a risk of fire, electric shock, or injury to a person
Read Instructions
: The Owner’s Manual should be read and understood before operation of your unit. Please, save these
instr
uctions for future reference and heed all warnings.
Clean only with dr
y cloth.
Pa
ckaging: Keep the box and packaging materials, in case the unit needs to be returned for service.
W
arning: To reduce the risk or fire or electric shock, do not expose this apparatus to rain or moisture. Do not
use this apparatus near w
ater!
W
arning: When using electric products, basic precautions should always be followed, including the following:
Power Sources
Your unit should be connected to a power source only of the voltage specified in the owners manual or as marked on the
unit. This unit has a polarized plug. Do not use with an extension cord or receptacle unless the plug can be fully inserted.
Precautions should be taken so that the grounding scheme on the unit is not defeated. An apparatus with CLASS I
construction shall be connected to a Mains socket outlet with a protective earthing connection. Where the MAINS plug or
an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.
Hazards
Do not place this product on an unstable cart, stand, tripod, bracket or table. The product may fall, causing serious personal
injury and serious damage to the product. Use only with cart, stand, tripod, bracket, or table recommended by the
manufacturer or sold with the product. Follow the manufacturer’s instructions when installing the product and use mounting
accessories recommended by the manufacturer. Only use attachments/accessories specified by the manufacturer
Note: Prolonged use of headphones at a high volume may cause health damage on your ears.
The apparatus should not be exposed to dripping or splashing water; no objects filled with liquids should be
placed on the apparatus.
Terminals marked with the “lightning bolt” are hazardous live; the external wiring connected to these terminals require
installation by an instructed person or the use of ready made leads or cords.
Ensure that proper ventilation is provided around the appliance. Do not install near any heat sources such as radiators,
heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
No naked flame sources, such as lighted candles, should be placed on the apparatus.
Power Cord
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than
the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided
for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
The AC supply cord should be routed so that it is unlikely that it will be damaged. Protect the power cord from being walked on
or pinched particularly at plugs. If the AC supply cord is damaged DO NOT OPERAT E THE UNIT. To completely disconnect
this apparatus from the AC Mains, disconnect the power supply cord plug from the AC receptacle. The mains plug of the
power supply cord shall remain readily operable.
Unplug this apparatus during lightning storms or when unused for long periods of time.
Service
The unit should be serviced only by qualified service personnel. Servicing is required when the apparatus has
been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects
have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally,
or has been dropped. Disconnect power before servicing!
Instructions relatives au risque de feu, choc électrique, ou blessures aux personnes
Veuillez Lire le Manuel: Il contient des informations qui devraient êtres comprises avant l’opération de votre appareil.
Conservez. Gardez S.V.P. ces instructions pour consultations ultérieures et observez tous les avertissements.
Nettoyez seulement avec le tissu sec.
Emballage: Conservez la boite au cas ou l’appareil devait être retourner pour réparation.
Avertissement: Pour réduire le risque de feu ou la décharge électrique, n'exposez pas cet appareil à la pluie ou à l'humidité.
N’utilisez pas cet appareil près de l’eau!
Attention: Lors de l’utilisation de produits électrique, assurez-vous d’adhérer à des précautions de bases incluant celle qui suivent:
Alimentation - L’ appareil ne doit être branché qu’à une source d’alimentation correspondant au voltage spécifié dans
le manuel ou tel qu’indiqué sur l’appareil. Cet appareil est équipé d’une prise d’alimentation polarie. Ne pas utiliser cet
appareil avec un cordon de raccordement à moins qu’il soit possible d’insérer complètement les trois lames. Des précautions
doivent êtres prises afin d’eviter que le système de mise à la terre de l’appareil ne soit désengagé. Un appareil construit
selon les normes de CLASS I devrait être raccordé à une prise murale d’alimentation avec connexion intacte de mise à la
masse. Lorsqu’une prise de branchement ou un coupleur d'appareils est utilisée comme dispositif de débranchement, ce
dispositif de débranchement devra demeurer pleinement fonctionnel avec raccordement à la masse.
Risque -
Ne pas placer cet appareil sur un chariot, un support, un trépied ou une table instables. L’appareil pourrait tomber et
blesser quelqu’un ou subir des dommages importants.
Utiliser seulement un chariot, un support, un trépied ou une table
recommandés par le fabricant ou vendus avec le produit. Suivre les instructions du fabricant pour installer l’appareil et utiliser les
accessoires recommandés par le fabricant. Utilisez seulement les attachements/accessoires indiqués par le fabricant.
Note: L'utilisation prolongée des écouteurs à un volume éle peut avoir des conséquences néfastes sur la santé
sur vos oreilles.
Il convient de ne pas placer sur l’appareil de sources de flammes nues, telles que des bougies allumées.
L’appeil ne doit pas être exposé à des égouttements d’eau ou des éclaboussures et qu’aucun objet rempli de liquide tel
que des vases ne doit être placé sur l’appareil.
Assurez que lappareil est fourni de la propre ventilation. Ne procédez pas à l’installation près de source de chaleur tels
que radiateurs, registre de chaleur, fours ou autres appareils (incluant les amplificateurs) qui produisent de la chaleur.
Les dispositifs marqués d’une symbole “d’éclairsont des parties dangereuses au toucher et que les câblages
extérieurs connectés à ces dispositifs de connection extérieure doivent être effectivés par un opérateur formé ou en
utilisant des cordons déjà préparés.
Cordon d’Alimentation - Ne pas enlever le dispositif de sécurité sur la prise polarisée ou la prise avec tige de
mise à la masse du cordon d’alimentation. Une prise polarisée dispose de deux lames dont une plus large que l’autre. Une
prise avec tige de mise à la masse dispose de deux lames en plus d’une troisième tige qui connecte à la masse. La lame plus
large ou la tige de mise à la masse est prévu pour votre sécurité. La prise murale est désuète si elle n’est pas conçue pour
accepter ce type de prise avec dispositif de sécurité. Dans ce cas, contactez un électricien pour faire remplacer la prise murale.
Évitez d’endommager le cordon d’alimentation. Protégez le cordon d’alimentation. Assurez-vous qu’on ne marche pas dessus
et qu’on ne le pince pas en particulier aux prises. N’UTILISEZ PAS L’ APPA REIL si le cordon d’alimentation est endommagé.
Pour débrancher complètement cet appareil de l’alimentation CA principale, déconnectez le cordon d’alimentation de la prise
d’alimentation murale. Le cordon d’alimentation du bloc d’alimentation de l’appareil doit demeurer pleinement fonctionnel.
Débranchez cet appareil durant les orages ou si inutilisé pendant de longues périodes.
Service - Consultez un technicien qualifié pour l’entretien de votre appareil. L'entretien est nécessaire quand l'appareil a été
endommagé de quelque façon que se soit. Par exemple si le cordon d’alimentation ou la prise du cordon sont endommagés, si il y
a eu du liquide qui a été renversé à l’intérieur ou des objets sont tombés dans l'appareil, si l'appareil a été exposé à la pluie ou à
l'humidité, si il ne fonctionne pas normalement, ou a été échappé. Débrancher l’appareil avant d’enlever les couvercles!
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
FOLLOW ALL INSTRUCTIONS SUIVEZ TOUTES LES INSTRUCTIONS
AVIS: AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE, N’ENLEVEZ PAS LE COUVERT (OU
LE PANNEAU ARRIERE) NE CONTIENT AUCUNE PIECE REPARABLE PAR L’UTILISATEUR.
CONSULTEZ UN TECHNICIEN QUALIFIE POUR L’ENTRETIENT CE PRODUIT EST POUR L’USAGE À
L’INTÉREUR SEULEMENT. LES PACKS BATTERIES INSTALLÉS NE DOIVENT PAS ÊTRE EXPOSÉS
À UNE CHALEUR EXCESSIVE TELLE QUE LE ENSOLEILLEMENT, LE FEU OU SIMILAIRES.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL. THIS DEVICE IS FOR INDOOR USE ONLY!
INSTALLED BATTERY PACKS SHALL NOT BE EXPOSED TO EXCESSIVE HEAT
SUCH AS SUNSHINE, FIRE OR THE LIKE.
SEPARATE
COLLECTION
WEEE
DO NOT
PUSH OR PULL
The Lightning Flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated
"dangerous voltage" within the product enclosure that may be of sufficient magnitude to constitute a risk of shock to persons
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance
(servicing) instructions in the literature accompanying the product
1.
Read these instructions.
2.
Keep these instructions.
3.
Heed all warnings.
4.
Follow all instructions.
5.
Do not use this apparatus near water.
6.
Clean only with dry cloth.
7.
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8.
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9.
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A
grounding type plug has two b
lades and a third grounding prong. The wide blade or the third prongs are provided for your safety. If the provided
plug does not fit into y
our outlet, consult an electrician for replacement of the obsolete outlet.
10.
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit
from the apparatus
.
11.
Only use attachments/accessories specified by the manufacturer.
12.
Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution
when mo
ving the cart/apparatus combination to avoid injury from tip-over.
13.
Unplug this apparatus during lightning storms or when unused for long periods of time.
14.
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as
po
wer-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture
, does not operate normally, or has been dropped.
W
ARNING:
To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture and objects filled with liquids, such as vases, should not be
placed on this apparatus
.
To completely disconnect this apparatus from the ac mains, disconnect the power supply cord plug from the ac receptacle.
The mains plug of the power supply cord or appliance coupler shall remain readily accessible.
Le symbole représentant un éclair avec une flèche à l’intérieur d’un triangle équilatéral est utilisé pour prévenir l’utilisateur de la
présence d’une tension électrique dangereuse non isolée à l’intérieur de l’appareil. Cette tension est d’un niveau suffisamment
éle pour représenter un risque d’électrocution
Le symbole représentant un point d’exclamation à l’intérieur d’un triangle équilatéral, signale à l’utilisateur la présence d’instructions
importantes relatives au fonctionnement et à l’entretien de l’appareil dans cette notice d’installation
1. Lisez ces instructions.
2. Conservez ces instructions.
3. Respecter tous les avertissements.
4. Suivez toutes les instructions.
5. N'utilisez pas l'appareil près de l'eau.
6. Nettoyer uniquement avec chiffon sec.
7. Ne bloquez pas les ouvertures de ventilation. Installer en suivant les instructions du fabricant.
8. Ne pas installer près des sources de chaleur telles que radiateurs, bouches de chaleur, four ou autres appareils (y compris les amplificateurs)
produisant de la chaleur.
9. N'annulez pas l'objectif sécuritaire de la fiche polarisée ou de la tige de mise à la terre. Une fiche polarisée possède deux lames avec une plus
large que l'autre. Une prise avec mise à la terre possède deux lames et une troisième tige. La lame large ou la troisième tige sont fournis pour
votre sécurité. Si la fiche n'entre pas dans votre prise, consultez un électricien pour remplacer la prise obsolète.
10. Protéger le cordon d'alimentation des piétinements ou pincements en particulier près des fiches, des prises de courant et au point de
sortie de l'appareil.
11. Utilisez uniquement les accessoires spécifiés par le fabricant.
12. Utiliser uniquement avec un charriot, stand, trépied ou une table spécifiée par le fabricant, ou vendus avec l'appareil.
13. Débranchez l'appareil durant un orage ou lorsqu'il reste inutilisé pendant de longues périodes de temps.
14. Confiez toute réparation à un technicien qualifié. Une réparation est nécessaire lorsque l'appareil a été endommagé de quelque façon que ce
soit; comme lorsque le cordon d'alimentation ou la fiche est endommagé, lorsque du liquide a été renversé ou des objets sont tombés à l'intérieur,
lorsque l'appareil a été exposé à la pluie ou l'humidité, ne fonctionne pas normalement, ou est tombé.
AVERTISSEMENT:
• Pour réduire les risques d'incendie ou de choc électrique, ne pas exposer cet appareil à la pluie ou à l'humidité et ne placez pas d’objets contenant
des liquides, tels que des vases, sur l’appareil.
• Pour isoler totalement cet appareil de l'alimentation secteur, débranchez totalement son cordon d'alimentation du réceptacle CA.
• La prise du cordon d’alimentation ou du prolongateur, si vous en utilisez un comme dispositif de débranchement, doit rester facilement accessible
CAUTION
TO PREVENT ELECTRIC SHOCK HAZARD,
DO NOT CONNECT TO MAINS POWER SUPPLY
WHILE GRILLE IS REMOVED.
AV IS
POUR PRÉVENIR LES RISQUES D'ÉLECTROCUTION,
NE PAS RACCORDER A L’ALIMENTATION ÉLECTRIQUE ALORS
QUE LA GRILLE EST RETIRÉE.
The DO NOT STACK symbol is intended to alert the user that the product
shall not be vertically stacked because of the nature of the product.
La symbole NE PAS EMPILER est pour alerter l'utilisateur que le produit
ne doit pas être empilé verticalement en raison de la nature du produit.
NOT TO BE SERVICED
BY USERS
CAUTION: HOT SURFACE
ATTENTION: SURFACE CHAUDE
IEC 60417-5041
1
Synergy SA115S Powered Speaker
Thank you for choosing Yorkville’s Synergy SA115S subwoofer, the companion subwoofer to the SA153. The SA se-
ries excels in sound reinforcement applications where a line array is desired but cannot be easily accommodated.
Cabinet Features
The SA115S is constructed of high strength multiply birch plywood for ultimate durability. The SA115S uses s a
single 15-inch long-throw woofer.
Electronic Features
A Yorkville proprietary DSP platform provides processing to prevent over-excursion (X-Max), voice coil over-
heating (VC thermal) and clipping. The DSP uses IIR lters for crossover and equalization and there is a small
delay added to time align with the SA153 top box. The X-Max limiter and the VC thermal limiter are both fre-
quency sensitive and calibrated to match the characteristics of the driver and cabinet system. The VC-thermal
limiter can be advanced to limit the power draw in cases where there is less than ample power available. The
X-Max limiter is faster, pretty much instantaneous. The VC-thermal limiter is slower reacting, typically operating
near the end of a bass beat at 120 bpm.
The amplier is a high headroom Class-D design. There is a large capacitor bank so that bass transients are
less dependent on the quality of the power line.
The limiter indicators indicate when the X-max or VC thermal limiters are active. Typically, the X-max
limiter is more active but this is content dependent. The effect of the line power advance can be observed by
carefully watching these limit lights as the control is changed while operating in limit. The VC-therm indicator
will come on sooner as the Average Power limiter is advanced. With many types of music, the effect of the
VC-therm limiter will be minimal.
SUB
LEVEL
LINE
CURRENT
LIMIT
dB
3
3
AMPS
4
4
5
5
2
2
Off
Off
8
-
12
-
24
4
6
-
6
2
-
2
1
0
0
Activity
Pwr
Limit
X-MAX
VC
Therm
Input Clip
ALL CONNECTED IN PARALLEL
5A = MAX Output
4A = 90% Output
3A = 80% Output
2A = 60% Output
2
1. Power Switch and Indicator
The green power LED illuminates when the power switch is turned to the On position and AC voltage is sup-
plied. When the power is removed or the power switched is moved to the off position the green power indicator
will blink while the power supply is discharging. The processing circuitry will not reboot unless the power supply
is fully discharged before being turned back on. It is not necessary to reboot however. Turning the power back
on before the power supply is discharged will simply resume normal operation.
2. PowerCON TRUE AC Loop Thru
As a standard, the AC inlet on the SA115S accepts locking PowerCON TRUE power cords. There is also an AC
outlet that can be used to loop power through to other cabinets in your array using a male to female PowerCON
TRUE looping power cord. Check with your local Yorkville dealer for availability of these accessory cords.
IMPORTANT: DO NOT EXCEED THE CURRENT RATING OF THE POWER and ACCESSORY CORDS.
PLEASE READ THE SECTION OF THIS MANUAL CALLED CASCADE INSTALLATION
3. Input Jack
This female-XLR accepts line level XLR microphone cables. For best noise reduction use balanced sources.
4. Dual Link Outputs
These XLR male connectors can be used with a standard XLR cable to daisy-chain up to 20 SA115S or SA315
cabinets without signal degradation. Simply loop from one cabinet’s Link jack to the next cabinets Input jack. In
many cases this limit of 20 cabinets can be exceeded, consult Yorkville Sound for more details.
5. SA115S Level Control
This control adjusts the volume level of the SA115S relative to the input signal level. Mixers and other audio
sources connected to the SA115S tend to have different output voltages, which mean the level control on the
SA115S is used to ne tune the cabinet’s volume relative to the mixer settings. It is perfectly acceptable to set
the SA115S Level above or below the center 0 dB setting.
6. Clip, X-Max, VC-Therm, Activity Indicators
The Clip and Limit LED indicators illuminate to guide the user to proper operating levels.
Illumination either of the yellow Limit LEDs indicates that a level has been reached where the SA115S limit-
ers are reducing the signal internally to prevent damage or distortion. It also indicates that further increases in
input level or increasing the SA115S Level control position will not appreciably increase acoustic output.
The red Clip LED indicates that the input level is excessive and further increases in level will cause severe
distortion The input signal should be reduced at the source until Clip activity ceases. The clip indicator comes
on at 12 Vrms,16 volts peak. The input clips at 17 Vrms, 24 volts peak.
The activity Indicator comes on at 5 mVrms or -45 dBV.
7. Line Current Limit Control
The Line Current Limit control allows the power to be reduced to allow operation on limited power availabil-
ity. Full power transients will be allowed through but if the average power is excessive then the power will be
limited. This control works by advancing the limiter that limits the voice coil temperature and by monitoring
the current draw. In the 5 amp position the average power is limited only by the voice coil temperature. In the
4 amp position with most music, the limiter will be only active occasionally depending on the music content.
In the 3 amp position certain types of music will not be limited, primarily music without deep bass or where
the bass is unprocessed. The 2 amp position will signicantly reduce the output when the music content has
continuous bass content below 45 Hz. The green power on indicator will dim to indicate when the line cur-
rent limiter is active. A small amount of dimming indicates that the advanced thermal limiter is active while
signicant dimming indicates that the line current monitoring system has detected excessive line current.
Low line voltage typically due to long power supply cables may cause excessive line current, the line current
monitoring system will prevent this from tripping the power source circuit breakers.
3
Enceinte Ampliée Synergy SA115S
Nous vous remercions d’avoir choisi le caisson de basse Synergy SA115S de Yorkville, le caisson de basse com-
pagnon du SA153. La série SA excelle dans les applications de renforcement du son où un système Line array est
souhaité mais ne peut être facilement installé.
Caractéristiques de l’Enceinte
Le SA115S est construit en contreplaqué de bouleau multi-plis haute résistance pour une durabilité ultime. Le
SA115S utilise un seul woofer de 15 pouces à longue portée.
Caractéristiques Électroniques
Une plateforme DSP propriétaire de Yorkville assure le traitement pour éviter la sur-excursion (X-Max), la surchauffe de la
bobine mobile (VC thermique) et l’écrêtage. Le DSP utilise des ltres IIR pour le crossover et l’égalisation et un petit délai
est ajouté pour s’aligner avec l’enceinte SA153. Le limiteur X-Max et le limiteur thermique VC sont tous deux sensibles à
la fréquence et calibrés pour correspondre aux caractéristiques du système de haut-parleurs et de caissons. Le limiteur
thermique VC peut être avancé pour limiter la consommation d’énergie dans les cas où il n’y a pas assez de puissance
disponible. Le limiteur X-Max est plus rapide, presque instantané. Le limiteur VC-thermal réagit plus lentement et fonc-
tionne généralement vers la n d’un battement de basse à 120 bpm.
L’amplicateur est une conception de classe D à haute extension dynamique. Il est équipé d’une grande banque de
condensateurs an que les transitoires des basses dépendent moins de la qualité de la ligne électrique.
Les indicateurs du limiteur indiquent quand les limiteurs thermiques X-max ou VC sont actifs. En général, le
limiteur X-max est plus actif mais cela dépend du contenu. L’effet de l’avance de la puissance de ligne peut être
observé en surveillant attentivement ces voyants de limiteur lorsque la commande est modiée pendant le fonc-
tionnement en limite. Le voyant VC-therm s’allume plus tôt lorsque le limiteur de Puissance Moyenne est avancé.
Avec de nombreux types de musique, l’effet du limiteur VC-therm sera négligeable.
SUB
LEVEL
LINE
CURRENT
LIMIT
dB
3
3
AMPS
4
4
5
5
2
2
Off
Off
8
-
12
-
24
4
6
-
6
2
-
2
1
0
0
Activity
Pwr
Limit
X-MAX
VC
Therm
Input Clip
ALL CONNECTED IN PARALLEL
5A = MAX Output
4A = 90% Output
3A = 80% Output
2A = 60% Output
4
1. Interrupteur et Indicateur d’Alimentation
Le voyant d’alimentation vert s’allume lorsque l’interrupteur d’alimentation est réglé sur la position ON et que la tension CA
est appliquée. Lorsque l’alimentation est coupée ou que l’interrupteur d’alimentation est placé en position OFF, le voyant vert
d’alimentation clignote pendant que l’alimentation se décharge. Le circuit de traitement ne redémarrera pas si l’alimentation
n’est pas complètement déchargée avant d’être remise sous tension. Il n’est cependant pas nécessaire de redémarrer. Si vous
remettez l’appareil sous tension avant que l’alimentation ne soit déchargée, le fonctionnement normal reprendra simplement.
2. Boucle CA PowerCON TRUE
En standard, l’entrée CA du SA115S est compatible avec les cordons d’alimentation PowerCON TRUE à verrouil-
lage. Il y a également une prise CA qui peut être utilisée pour alimenter en boucle d’autres enceintes de votre
réseau en utilisant un cordon d’alimentation PowerCON TRUE mâle à femelle. Vériez auprès de votre revendeur
Yorkville local pour vérier la disponibilité de ces cordons accessoires.
IMPORTANT : NE PAS DÉPASSER LE COURANT MAXIMAL DES CORDONS D’ALIMENTATION ET
D’ACCESSOIRES. VEUILLEZ LIRE LA SECTION DE CE MANUEL INTITULÉE “INSTALLATION EN CASCADE”.
3. Prise d’Entrée
Cette prise femelle-XLR est compatible avec les câbles de microphone XLR de niveau ligne. Pour une meilleure
réduction du bruit, utilisez des sources équilibrées.
4. Sorties Dual Link
Ces connecteurs mâles XLR peuvent être utilisés avec un câble XLR standard pour relier en chaîne jusqu’à 20
enceintes SA115S ou SA315 sans dégradation du signal. Il suft de faire une boucle entre la prise Link d’une
enceinte et la prise Input de l’enceinte suivante. Dans de nombreux cas, cette limite de 20 enceintes peut être
dépassée, consultez Yorkville Sound pour plus de détails.
5. Commande de Niveau SA115S
Cette commande permet de régler le niveau de volume du SA115S par rapport au niveau du signal d’entrée. Les
tables de mixage et autres sources audio connectées au SA115S ont tendance à avoir des tensions de sortie dif-
férentes, ce qui signie que la commande de niveau sur le SA115S est utilisé pour afner le volume de l’enceinte
par rapport aux réglages de la table de mixage. Il est parfaitement acceptable de régler le niveau du SA115S au-
dessus ou au-dessous du réglage central de 0 dB.
6. Indicateurs d’Activité Clip, X-Max, VC-Therm,
Les indicateurs DEL Clip et Limit s’allument pour guider l’utilisateur vers les niveaux de fonctionnement appropriés.
L’illumination de l’une ou l’autre des DEL jaunes de limite indique qu’un niveau a été atteint où les limiteurs
du SA115S réduisent le signal de façon interne pour éviter tout dommage ou distorsion. Il indique égale-
ment que d’autres augmentations du niveau d’entrée ou de la position de la commande de niveau du SA115S
n’augmenteront pas sensiblement la sortie acoustique.
La DEL Clip rouge indique que le niveau d’entrée est excessif et que toute augmentation supplémentaire du
niveau entraînera une distorsion grave. Le signal d’entrée doit être réduit à la source jusqu’à ce que l’activité
d’écrêtage cesse. La DEL CLIP s’allume à 12 Vrms, 16 volts crête. L’entrée s’écrête à 17 Vrms, 24 volts crête.
L’indicateur d’activité s’allume à 5 mVrms ou -45 dBV.
7. Commande De Limite De Courant De Ligne
La commande de limite de courant de ligne permet de réduire la puissance pour permettre un fonctionnement avec une
disponibilité de puissance limitée. Les transitoires à pleine puissance seront permises, mais si la puissance moyenne est
excessive, la puissance sera limitée. Cette commande fonctionne en faisant avancer le limiteur qui limite la température de
la bobine mobile et en surveillant la consommation de courant. En position 5 ampères, la puissance moyenne est limitée
uniquement par la température de la bobine mobile. En position 4 ampères, avec la plupart des programmes musicaux, le
limiteur ne sera actif qu’occasionnellement, en fonction du contenu musical. En position 3 ampères, certains types de mu-
sique ne seront pas limités, principalement la musique sans basses profondes ou lorsque les basses ne sont pas traitées. La
position 2 ampères réduira signicativement la sortie lorsque le contenu musical contient des basses continues en dessous
de 45 Hz. Le témoin vert de mise sous tension s’assombrit pour indiquer que le limiteur de courant de ligne est actif. Une
faible gradation indique que le limiteur thermique avancé est actif, tandis qu’une gradation importante indique que le système
de surveillance du courant de ligne a détecté un courant de ligne excessif. Une faible tension de ligne, généralement due à
de longs cordons d’alimentation, peut provoquer un courant de ligne excessif. Le système de contrôle du courant de ligne
empêche ce phénomène de déclencher les disjoncteurs de la source d’alimentation.
5
T
yp
e de s
y
stème
Caisson de Basse actif
Actif ou
p
assif
Actif
Puissance du
p
ro
g
ramme
(
watts
)
4500 watts Pro
g
ramme
(
9000 watts crête
)
NPA maximum mesuré
(p
ondéré C
,
maintien maximum
)
129dB Cont. 135 dB crête
p
onse en fré
q
uence
(
Hz +/- 3dB
)
31 Hz - 100 Hz
Fré
q
uence de cou
p
ure
(
Hz
)
Passe-bas 100 Hz
Confi
g
uration de l'enceinte
Haut-
p
arleur à
p
avillon
Confi
g
uration des haut-
p
arleurs
1 haut-
p
arleur de
g
raves de 15
p
ouces
Driver
(
s
)
BF
Néod
y
me de 15
p
ouces avec bobine mobile de 4
,
5
p
ouces
Puissance nominale BF
(
watts
)
4500 watts
p
ro
g
ramme
(
9000 watts crête
)
Im
p
édance BF
(
ohms
)
Char
g
e de 4 ohms
Protection BF
Excursion
,
Thermi
q
ue de la bobine mobile
(
RMS
)
T
yp
e d'am
p
lificateur BF
Classe D
S
y
stème de refroidissement
Convection
Cordon d'alimentation Entrée Powercon True et sortie Loop Thru verrouillables et
amovibles
Interru
p
teur d'alimentation
Oui
Entrées
1 XLR avec 2x XLR sortie
p
arallèle
,
Im
p
édance 35k ohms
Sensibilité d'entrée
(
Vrms sinus
)
Entrée li
g
ne 1
,
4 au centre
,
0
,
56 au maximum
Commandes de niveau
Volume
,
-∞
,
0dB
,
8dB
(
Min
,
To
p,
Max
)
Commandes d'égalisationLimiteur thermique Advance pour la gestion de la consommation
d'éner
g
ie
Limiteur
Excursion
,
thermi
q
ue
(
RMS
),
écrêta
g
e
Indicateurs DELPuissance, Limite d'excursion, Limite thermique (RMS), Clip
d'entrée
,
Activi
Matériaux du boîtier
Contre
p
la
q
ué de bouleau multi
p
lis de 15 mm
Caractéristi
q
ues d'em
p
ila
g
e
Pieds en caoutchouc emboîtables
(
côtés
)
Retement / Finition
Peinture
Dimensions
(
PLH x L arrière
,
p
ouces
)
36
,
625
(y
com
p
ris les roulettes
)
x 17
,
750 x 35
,
250
Dimensions
(
PLH x L arrière
,
cm
)
93 x 45 x 82
Poids
(
livres/k
g)
165/74.9
*Spécifications sujettes à modification sans préavis
Spécifications
System Type Active Subwoofer
Active or PassiveActive
Program Power (watts)4500 watts Program (9000 watts peak)
Measured Max SPL (C-Weighted, Max Hold)129dB Cont. 135 dB Peak
Frequency Response (Hz +/- 3dB) 31 Hz - 100 Hz
Crossover Frequency (Hz) 100 Hz lowpass
Cabinet ConfigurationTapped Horn
Driver Configuration1x15-inch LF woofer
LF Driver(s)15-inch Neodymium with 4.5-inch Voice Coil
LF Program Power (watts)4500 watts program (9000 watts peak)
LF Impedance (ohms) 4 ohm Load
LF Protection Excursion, Voice Coil Thermal (RMS)
LF Amplifier Type Class D
Cooling Scheme Convection
Power CableRemovable Locking Powercon True Input and Loop Thru Output
Power Switch Yes
Inputs 1 XLR with 2x XLR Parallel out, Impedance 35k ohms
Input Sensitivity (Vrms Sine)Line in 1.4 at center, 0.56 at max
Level Controls Volume, -∞,0dB,8dB (Min, Top, Max)
EQ Controls Thermal Limiter Advance for power consumption management
LimiterExcursion, Thermal (RMS), Clipping
LED Indicators Power, Excursion Limit, Thermal (RMS) Limit, Input Clip, Activity
Enclosure MaterialsMultiply 15mm Birch Plywood
Stacking FeatureInterlocking Rubber Feet (Sides)
Covering / Finish Paint
Dimensions (DWH xbackW, inches)36.625 (including Casters) x 17.750 x 35.250
Dimensions (DWH xbackW, cm)93 x 45 x 82
Weight (lbs/kg) 165/74.9
*Specifications subject to change without notice
Specifications
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense.
Block Diagram SA115S
DESIGNED & MANUFA CTURED BY YORKVILLE SOUND
block-diagram-SYNERGY-SA115S-00-1v0
Output
Input
XLR
Sub
Level
50Hz
LP
AC Line
Current Sense
Line
Current
Limit
Microcontroller
DSP
ADC DAC
2
3
1
2
3
1
1
3
2
AMP
+
-
Act.
VC
ThermX-Max
Input
Clip
Limit
Pwr
Cascade Installation
The SA102and SA115S provide convenience outlets which can minimize wiring and improve overall
safety when used properly. Please carefully read all of the important safety tips shown below for long
and safe use of your equipment.
IMPORTANT
1. Do not overload the convenience outlet. Make sure power drawn from the first outlet does not
exceed the limits shown on the chassis. A chain consisting of two SA115S powered subwoofers and
two SA102 full range powered speakers as shown below would be safe.
2. Always inspect the cords and plugs before use. Do not use outlets or cords that have exposed wiring,
are worn or damaged. Replace electrical cords that have worn or damaged insulation and remember
to pull the plug, not the cord to extend the life of the cord itself.
3. The AC supply cord should be routed so that it is unlikely that it will be damaged. Protect the power
cord from being walked on or pinched. If the AC supply cord is damaged DO NOT OPERATE THE UNIT.
To completely disconnect this apparatus from the AC Mains, disconnect the power supply cord plug
from the AC receptacle. The mains plug of the power supply cord shall remain readily operable.
Unplug this apparatus during lightning storms or when unused for long periods of time. Route cords
away from traffic to avoid tripping hazards and unnecessary wear on the power cord.
4. Never Break Off the Third Prong on a Plug. Replace broken 3-prong plugs and make sure the third
prong is properly grounded.
5. Keep line cords away from heat, water and oil. They can damage the insulation and create a shock
hazard.
6. Do not tie cords in tight knots. Knots can cause short circuits and shocks. Loop the cords or use a
twist lock plug.
7. Be aware that unusually warm or hot outlets or cords may be a sign that an unsafe wiring condition
exists. Unplug any cords or extension cords from these outlets and do not use until a qualified
electrician has checked the wiring.
SYNERGY-Convenience-Récepatacle-(Cascade-Installaon)-fr.docx
Installaon en cascade
La gamme de produits SYNERGY propose des prises de courant alternaf qui minimisent
le câblage et améliorent la sécurité générale
lorsqu'elles sont ulisées
correctement. Prenez soin de lire aenvement tous les conseils de sécurité importants indiqués ci-
dessous
pour une ulisaon prolongée et sécuritaire de votre équipement.
1. Connectez toujours l'
équipement à un circuit avec une mise à la terre électrique appropriée.
2.
Ne surchargez pas les cordons d'alimentaon et les prises de courant.
Yorkv
ille fournit des cordons d'alimentaon cerfiés de gros calibre qui distribuent en toute sécurité jusqu'à 12 A aux équipements
interconnectés. Il est importa
nt de savoir quelles sont les exigences totales en maère de courant pour tous les équipements que
vous
souhaitez connecter en chaîne.
Le courant nominal de tous nos produits SYNERGY est indiqué à l'arriè
re du boîer. Ce chiffre représente le courant typique
consommé à des niveaux de puissance modérés. Si le coura
nt nominal total est inférieur à 12A, le système fonconnera en toute
sécurité même si les amplificateurs fonconnent à des niv
eaux de puissance plus élevés.
Voici un exemple d'ulisaon
du courant nominal pour assurer que vous ne surchargez pas les cordons d'alimentaon.
Le courant nominale du SA102 est 1.0A à 120V, donc deux SA102 consommeront 2.0A
.
Le courant nominale du SA115S est 3.0A à 120V, donc deux SA1115S consommeront 6.0A.
Le
courant nominal total des quatre appareils est de 8,0 A.
C'est moins que la limit
e de 12A et ce système fonconnera en toute sécurité.
NOTE :
Le
SA221SKIT est une opon 16A qui existe pour le subwoofer SA221S et ce cordon d'alimentaon peut distribuer en toute sécurité
jusqu'à 16A.
3.
Inspectez toujours les cordons et les fiches avant de les uliser. N'ulisez pas de prises ou de cordons dont le câblage
est expo, qui sont usés ou endommagés. Remplacez les cordons d’alimentaon dont l'isolaon est usée ou
endommagée et n'oubliez pas de rer sur la fiche, et non sur le cordon, pour prolonger la durée de vie du cordon lui-
me. Veuillez remplacer le cordon par un cordon robuste équivalent fourni par le fabricant.
4.
Le cordon d'alimentaon CA doit être acheminé de manière à ce qu'il soit peu probable qu'il soit endommagé.
Protégez le cordon d'alimentaon pour qu'il ne soit pas piéné ou pincé. NE PAS FAIRE FONCTIONNER L’APPAREIL si
le cordon d'alimentaon CA est endommagé. Pour connecter complètement cet appareil du secteur, débranchez la
fiche du cordon d'alimentaon de la prise de courant. La fiche du cordon d'alimentaon doit rester facilement
accessible. Débranchez cet appareil pendant les orages ou lorsqu'il n'est pas ulisé pendant de longues riodes.
Acheminez les cordons
à l'écart de la circulaon pour éviter les risques de trébuchement et l'usure inule du cordon
d'alimentaon.
5.
Ne cassez jamais la troisième broche d'une fiche. Remplacez les fiches à trois broches cassées et assurez-vous que la
troisième broche est correctement mise à la terre.
6.
Maintenez les cordons d’alimentaon à l'écart de la chaleur, de l'eau et de l'huile. Ils peuvent endommager l'isolaon
et créer un risque de choc.
7. Ne fa
ites pas de nœuds serrés avec les cordons. Les nœuds peuvent entraîner des courts-circuits et des chocs. Faites
des boucles avec les cordons ou ulisez un système “Twist-lock”.
Unlimited Warranty
Yorkville's two and ten-year unlimited warranty on this product is transferable
and does not require registration with Yorkville Sound or your dealer. If this
product should fail for any reason within two years of the original purchase
date (ten years for the wooden enclosure), simply return it to your Yorkville
dealer with original proof of purchase and it will be repaired free of charge.
This includes all Yorkville products, except for the YSM Series studio
monitors, Coliseum Mini Series and TX Series Loudspeakers.
Freight charges, consequential damages, weather damage, damage as a result
of improper installation, damages due to exposure to extreme humidity, accident
or natural disaster are excluded under the terms of this warranty. Warranty does
not cover consumables such as vacuum tubes or par bulbs. See your Yorkville
dealer for more details. Warranty valid only in Canada and the United States.
Garantie Illimitée
La garantie illimitée de deux et dix ans de ce produit est transférable. Il n`est pas
nécessaire de faire enregistrer votre nom auprès de Yorkville Sound ou de votre
détaillant. Si, pour une raison quelconque, ce produit devient défectueux durant
les deux années qui suivent la date d`achat initial (dix ans pour l`ébénisterie),
retournez-le simplement à votre détaillant Yorkville avec la preuve d`achat original
et il sera réparé gratuitement. Ceci inclus tous les produits Yorkville à l`exception
de la série de moniteurs de studio YSM, la mini série Coliseum et de la série TX.
Les frais de port et de manutention ainsi que les dommages indirects ou
dommages causés par désastres naturels, extrême humidité ou mauvaise
installation ne sont pas couverts par cette garantie. Cette garantie ne couvre
pas les produits consommables tels que lampe d`amplificateur ou ampoules
"PAR". Voir votre détaillant Yorkville pour plus de détails. Cette garantie n’est
valide qu’au Canada et aux États Unis d’Amérique.
www.yorkville.com
www.yor kville.com
REAL Gear.
REAL People.
REAL Gear.
REAL People.
Yorkville Sound
550 Granite Court
Pickering, Ontario
L1W-3Y8 CANADA
Canada
Voice: (905) 837-8481
Fax: (905) 837-8746
Yorkville Sound Inc.
4625 Witmer Industrial Estate
Niagara Falls, New York
14305 USA
U.S.A.
Voice: (716) 297-2920
Fax: (716) 297-3689
Printed in Canada
Two & Ten Year Warranty
Two
&
&
Ten
U.S.A.
Yorkville Sound Inc.
4625 Witmer Industrial Estate
Niagara Falls, New Yo rk
14305, USA
Voice: 716-297-2920
Fax: 716-297-3689
WORLD HEADQUARTERS
CANADA
Yorkville Sound Limited
550 Granite Court
Pickering, Ontario
L1W 3Y8 CANADA
Voice: 905-837-8481
Fax: 905-837-8746
Manual-Owners-SYNERGY-SA115S-00-1v0 • May 11, 2021
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

YORKVILLE SA115S Le manuel du propriétaire

Catégorie
Équipement musical supplémentaire
Taper
Le manuel du propriétaire

dans d''autres langues