YORKVILLE SA221S Manuel utilisateur

Catégorie
Équipement musical supplémentaire
Taper
Manuel utilisateur
SERVICE MANUAL
Synergy SA221S
SA221S
SMT Disclaimer
Due to the complex nature of the use of SMT installed components
in Yorkville equipment, we highly caution all service technicians in
attempting to repair or replace SMT factory installed components.
Many of these components may be glued prior to initial soldering.
Replacing SMT components requires expensive
specialized de-soldering equipment and training.
Yorkville Sound will repair and replace defective SMT components
to ensure proper quality assurance and installation is maintained.
U.S.A.
Yorkville Sound Inc.
4625 Witmer Industrial Estate
Niagara Falls, New York
14305, USA
Voice: 716-297-2920
Fax: 716-297-3689
WORLD HEADQUARTERS
CANADA
Yorkville Sound Limited
550 Granite Court
Pickering, Ontario
L1W 3Y8 CANADA
Voice: 905-837-8481
Fax: 905-837-8746
Manual-Service-SA221S-00-1v0 • May 21, 2021
The exclamation point within an equilatereal triangle is intended to alert the
user to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
Le point d’exclamation à l’intérieur d’un triangle équilatéral est prévu pour alerter
l’utilisateur de la présence d’instructions importantes dans la littérature accompagnant
l’appareil en ce qui concerne l’opération et la maintenance de cet appareil.
This lightning flash with arrowhead symbol, within
an equilateral triangle, is intended to alert the user to the presence of
uninsulated “dangerous voltage” within the product’s enclosure that may be
of sufficient magnitude to constitute a risk of electric shock to persons.
Ce symbole d’éclair avec tête de flèche dans un triangle équilatéral est prévu pour alerter
l’utilisateur de la présence d’un «voltage dangereux» non-isolé à proximité de l’enceinte du
produit qui pourrait être d’ampleur suffisante pour présenter un risque de choque électrique.
DOC-Safety-5v0+UL60065-00-1v8 • February 24, 2020
Instructions pertaining to a risk of fire, electric shock, or injury to a person
Read Instructions: The Owner’s Manual should be read and understood before operation of your unit. Please, save these
instructions for future reference and heed all warnings.
Clean only with dry cloth.
Packaging: Keep the box and packaging materials, in case the unit needs to be returned for service.
Warning: To reduce the risk or fire or electric shock, do not expose this apparatus to rain or moisture. Do not
use this apparatus near water!
Warning: When using electric products, basic precautions should always be followed, including the following:
Power Sources
Your unit should be connected to a power source only of the voltage specified in the owners manual or as marked on the
unit. This unit has a polarized plug. Do not use with an extension cord or receptacle unless the plug can be fully inserted.
Precautions should be taken so that the grounding scheme on the unit is not defeated. An apparatus with CLASS I
construction shall be connected to a Mains socket outlet with a protective earthing connection. Where the MAINS plug or
an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.
Hazards
Do not place this product on an unstable cart, stand, tripod, bracket or table. The product may fall, causing serious personal
injury and serious damage to the product. Use only with cart, stand, tripod, bracket, or table recommended by the
manufacturer or sold with the product. Follow the manufacturer’s instructions when installing the product and use mounting
accessories recommended by the manufacturer. Only use attachments/accessories specified by the manufacturer
Note: Prolonged use of headphones at a high volume may cause health damage on your ears.
The apparatus should not be exposed to dripping or splashing water; no objects filled with liquids should be
placed on the apparatus.
Terminals marked with the “lightning bolt” are hazardous live; the external wiring connected to these terminals require
installation by an instructed person or the use of ready made leads or cords.
Ensure that proper ventilation is provided around the appliance. Do not install near any heat sources such as radiators,
heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
No naked flame sources, such as lighted candles, should be placed on the apparatus.
Power Cord
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than
the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided
for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
The AC supply cord should be routed so that it is unlikely that it will be damaged. Protect the power cord from being walked on
or pinched particularly at plugs. If the AC supply cord is damaged DO NOT OPERATE THE UNIT. To completely disconnect
this apparatus from the AC Mains, disconnect the power supply cord plug from the AC receptacle. The mains plug of the
power supply cord shall remain readily operable.
Unplug this apparatus during lightning storms or when unused for long periods of time.
Service
The unit should be serviced only by qualified service personnel. Servicing is required when the apparatus has
been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects
have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally,
or has been dropped. Disconnect power before servicing!
Instructions relatives au risque de feu, choc électrique, ou blessures aux personnes
Veuillez Lire le Manuel: Il contient des informations qui devraient êtres comprises avant l’opération de votre appareil.
Conservez. Gardez S.V.P. ces instructions pour consultations ultérieures et observez tous les avertissements.
Nettoyez seulement avec le tissu sec.
Emballage: Conservez la boite au cas ou l’appareil devait être retourner pour réparation.
Avertissement: Pour réduire le risque de feu ou la décharge électrique, n'exposez pas cet appareil à la pluie ou à l'humidité.
N’utilisez pas cet appareil près de l’eau!
Attention: Lors de l’utilisation de produits électrique, assurez-vous d’adhérer à des précautions de bases incluant celle qui suivent:
Alimentation - L’appareil ne doit être branché qu’à une source d’alimentation correspondant au voltage spécifié dans
le manuel ou tel qu’indiqué sur l’appareil. Cet appareil est équipé d’une prise d’alimentation polarisée. Ne pas utiliser cet
appareil avec un cordon de raccordement à moins qu’il soit possible d’insérer complètement les trois lames. Des précautions
doivent êtres prises afin d’eviter que le système de mise à la terre de l’appareil ne soit désengagé. Un appareil construit
selon les normes de CLASS I devrait être raccordé à une prise murale d’alimentation avec connexion intacte de mise à la
masse. Lorsqu’une prise de branchement ou un coupleur d'appareils est utilisée comme dispositif de débranchement, ce
dispositif de débranchement devra demeurer pleinement fonctionnel avec raccordement à la masse.
Risque - Ne pas placer cet appareil sur un chariot, un support, un trépied ou une table instables. L’appareil pourrait tomber et
blesser quelqu’un ou subir des dommages importants. Utiliser seulement un chariot, un support, un trépied ou une table
recommandés par le fabricant ou vendus avec le produit. Suivre les instructions du fabricant pour installer l’appareil et utiliser les
accessoires recommandés par le fabricant. Utilisez seulement les attachements/accessoires indiqués par le fabricant.
Note: L'utilisation prolongée des écouteurs à un volume élevé peut avoir des conséquences néfastes sur la santé
sur vos oreilles.
Il convient de ne pas placer sur l’appareil de sources de flammes nues, telles que des bougies allumées.
L’appeil ne doit pas être exposé à des égouttements d’eau ou des éclaboussures et qu’aucun objet rempli de liquide tel
que des vases ne doit être placé sur l’appareil.
Assurez que lappareil est fourni de la propre ventilation. Ne procédez pas à l’installation près de source de chaleur tels
que radiateurs, registre de chaleur, fours ou autres appareils (incluant les amplificateurs) qui produisent de la chaleur.
Les dispositifs marqués d’une symbole “d’éclair” sont des parties dangereuses au toucher et que les câblages
extérieurs connectés à ces dispositifs de connection extérieure doivent être effectivés par un opérateur formé ou en
utilisant des cordons déjà préparés.
Cordon d’Alimentation - Ne pas enlever le dispositif de sécurité sur la prise polarisée ou la prise avec tige de
mise à la masse du cordon d’alimentation. Une prise polarisée dispose de deux lames dont une plus large que l’autre. Une
prise avec tige de mise à la masse dispose de deux lames en plus d’une troisième tige qui connecte à la masse. La lame plus
large ou la tige de mise à la masse est prévu pour votre sécurité. La prise murale est désuète si elle n’est pas conçue pour
accepter ce type de prise avec dispositif de sécurité. Dans ce cas, contactez un électricien pour faire remplacer la prise murale.
Évitez d’endommager le cordon d’alimentation. Protégez le cordon d’alimentation. Assurez-vous qu’on ne marche pas dessus
et qu’on ne le pince pas en particulier aux prises. N’UTILISEZ PAS L’APPAREIL si le cordon d’alimentation est endommagé.
Pour débrancher complètement cet appareil de l’alimentation CA principale, déconnectez le cordon d’alimentation de la prise
d’alimentation murale. Le cordon d’alimentation du bloc d’alimentation de l’appareil doit demeurer pleinement fonctionnel.
Débranchez cet appareil durant les orages ou si inutilisé pendant de longues périodes.
Service - Consultez un technicien qualifié pour l’entretien de votre appareil. L'entretien est nécessaire quand l'appareil a été
endommagé de quelque façon que se soit. Par exemple si le cordon d’alimentation ou la prise du cordon sont endommagés, si il y
a eu du liquide qui a été renversé à l’intérieur ou des objets sont tombés dans l'appareil, si l'appareil a été exposé à la pluie ou à
l'humidité, si il ne fonctionne pas normalement, ou a été échappé. Débrancher l’appareil avant d’enlever les couvercles!
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
FOLLOW ALL INSTRUCTIONS SUIVEZ TOUTES LES INSTRUCTIONS
AVIS: AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE, N’ENLEVEZ PAS LE COUVERT (OU
LE PANNEAU ARRIERE) NE CONTIENT AUCUNE PIECE REPARABLE PAR L’UTILISATEUR.
CONSULTEZ UN TECHNICIEN QUALIFIE POUR L’ENTRETIENT CE PRODUIT EST POUR L’USAGE À
L’INTÉREUR SEULEMENT. LES PACKS BATTERIES INSTALLÉS NE DOIVENT PAS ÊTRE EXPOSÉS
À UNE CHALEUR EXCESSIVE TELLE QUE LE ENSOLEILLEMENT, LE FEU OU SIMILAIRES.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL. THIS DEVICE IS FOR INDOOR USE ONLY!
INSTALLED BATTERY PACKS SHALL NOT BE EXPOSED TO EXCESSIVE HEAT
SUCH AS SUNSHINE, FIRE OR THE LIKE.
SEPARATE
COLLECTION
WEEE
DO NOT
PUSH OR PULL
The Lightning Flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated
"dangerous voltage" within the product enclosure that may be of sufficient magnitude to constitute a risk of shock to persons
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance
(servicing) instructions in the literature accompanying the product
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A
grounding type plug has two blades and a third grounding prong. The wide blade or the third prongs are provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit
from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution
when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as
power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
WARNING:
To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture and objects filled with liquids, such as vases, should not be
placed on this apparatus.
To completely disconnect this apparatus from the ac mains, disconnect the power supply cord plug from the ac receptacle.
The mains plug of the power supply cord or appliance coupler shall remain readily accessible.
Le symbole représentant un éclair avec une flèche à l’intérieur d’un triangle équilatéral est utilisé pour prévenir l’utilisateur de la
présence d’une tension électrique dangereuse non isolée à l’intérieur de l’appareil. Cette tension est d’un niveau suffisamment
élevé pour représenter un risque d’électrocution
Le symbole représentant un point d’exclamation à l’intérieur d’un triangle équilatéral, signale à l’utilisateur la présence d’instructions
importantes relatives au fonctionnement et à l’entretien de l’appareil dans cette notice d’installation
1. Lisez ces instructions.
2. Conservez ces instructions.
3. Respecter tous les avertissements.
4. Suivez toutes les instructions.
5. N'utilisez pas l'appareil près de l'eau.
6. Nettoyer uniquement avec chiffon sec.
7. Ne bloquez pas les ouvertures de ventilation. Installer en suivant les instructions du fabricant.
8. Ne pas installer près des sources de chaleur telles que radiateurs, bouches de chaleur, four ou autres appareils (y compris les amplificateurs)
produisant de la chaleur.
9. N'annulez pas l'objectif sécuritaire de la fiche polarisée ou de la tige de mise à la terre. Une fiche polarisée possède deux lames avec une plus
large que l'autre. Une prise avec mise à la terre possède deux lames et une troisième tige. La lame large ou la troisième tige sont fournis pour
votre sécurité. Si la fiche n'entre pas dans votre prise, consultez un électricien pour remplacer la prise obsolète.
10. Protéger le cordon d'alimentation des piétinements ou pincements en particulier près des fiches, des prises de courant et au point de
sortie de l'appareil.
11. Utilisez uniquement les accessoires spécifiés par le fabricant.
12. Utiliser uniquement avec un charriot, stand, trépied ou une table spécifiée par le fabricant, ou vendus avec l'appareil.
13. Débranchez l'appareil durant un orage ou lorsqu'il reste inutilisé pendant de longues périodes de temps.
14. Confiez toute réparation à un technicien qualifié. Une réparation est nécessaire lorsque l'appareil a été endommagé de quelque façon que ce
soit; comme lorsque le cordon d'alimentation ou la fiche est endommagé, lorsque du liquide a été renversé ou des objets sont tombés à l'intérieur,
lorsque l'appareil a été exposé à la pluie ou l'humidité, ne fonctionne pas normalement, ou est tombé.
AVERTISSEMENT:
• Pour réduire les risques d'incendie ou de choc électrique, ne pas exposer cet appareil à la pluie ou à l'humidité et ne placez pas d’objets contenant
des liquides, tels que des vases, sur l’appareil.
• Pour isoler totalement cet appareil de l'alimentation secteur, débranchez totalement son cordon d'alimentation du réceptacle CA.
• La prise du cordon d’alimentation ou du prolongateur, si vous en utilisez un comme dispositif de débranchement, doit rester facilement accessible
CAUTION
TO PREVENT ELECTRIC SHOCK HAZARD,
DO NOT CONNECT TO MAINS POWER SUPPLY
WHILE GRILLE IS REMOVED.
AVIS
POUR PRÉVENIR LES RISQUES D'ÉLECTROCUTION,
NE PAS RACCORDER A L’ALIMENTATION ÉLECTRIQUE ALORS
QUE LA GRILLE EST RETIRÉE.
The DO NOT STACK symbol is intended to alert the user that the product
shall not be vertically stacked because of the nature of the product.
La symbole NE PAS EMPILER est pour alerter l'utilisateur que le produit
ne doit pas être empilé verticalement en raison de la nature du produit.
NOT TO BE SERVICED
BY USERS
CAUTION: HOT SURFACE
ATTENTION: SURFACE CHAUDE
IEC 60417-5041
SERIAL NUMBER
SA221S
A-Z1789 / 1v2
DESIGNED & MANUFACTURED BY
YORKVILLE SOUND • TORONTO, CANADA
CONNECTED IN PARALLEL
INPUT
ActivityPower
SUB
LEVEL
Limit
X-MAX
Input
Clip
Off 8
-
12
-
24
4
6
-
6 2
-
2
1
0
dB
100Hz
Lowpass
LINE
CURRENT
LIMIT
12
AMPS
8
6
12A = MAX Output
8A = 80% Output
6A = 60% Output
OUTPUT
VC Therm
HP OUTPUT TO
SA315S ONLY
HP
OUTPUT
50Hz
50Hz
Lowpass
(for use with
SA315S)
15 AMP
POWER
Circuit
Breaker
On
Off
DISCONNECT POWER BEFORE SERVICING!
DEBRANCHER L’APPAREIL AVANT
D’ENLEVER LES COUVERCLES!
CAUTION - TO REDUCE THE RISK OF ELECTRIC SHOCK,
GROUNDING OF THE CENTRE PIN OF THIS PLUG MUST BE MAINTAINED!
ATTENTION - POUR RÉDUIRE LE RISQUE DE CHOC ÉLECTRIQUE, CONSERVER
LA MISE À LA TERRE ASSURÉE PAR LA TIGE CENTRALE DE CETTE FICHE!
NO USER SERVICEABLE PARTS INSIDE.
NE CONTIENT AUCUNE PIECE
REPARABLE PAR L’UTILISATEUR.
1A MAX ON
FIRST OUTLET
SEE OWNERS MANUAL FOR
CASCADE INSTALLATION
120V 60Hz
11A STANDALONE
12A MAX WITH
AC OUTLET
AND 15A LINE CORD
CAUTION: THIS EQUIPMENT REQUIRES A 15A OR 20A LINE CORD
ATTENTION: CET ÉQUIPMENT NÉCESSITE
UN CORDON DE LIGNE 15A OU 20A
Specifications
Active or Passive
Active
Program Power (watts)
6000 watts program 17000 watts peak
Measured Max SPL (C-Weighted, Max Hold)
130.6 dB Cont., 142.6 dB Peak
Frequency Response (Hz +/- 3dB)
28Hz-100Hz
Crossover Frequency (Hz)
50 or 100 Hz lowpass
Cabinet Configuration
Bass Reflex
Driver Configuration
2x21-inch LF woofer
LF Driver(s)
21-inch Neo with 4.5-inch Tetra Coil
LF Program Power (watts)
6000 watts Program, 17000 watts Peak
LF Impedance (ohms)
LF impedance 2 amplifiers, 4 ohms per amplifier
LF Protection
Excursion, Voice Coil Thermal (RMS)
LF Power Amplifier (watts)
6000 watts program (17000 watts peak)
LF Amplifier Type
Class D
Cooling Scheme
Convection
Power Cable
Removable Locking Powercon True Input and Loop Thru
Power Switch
Yes
Power Consumption (typ/max)
1440 VA / 1920 VA
Inputs
1 XLR with 2x XLR Parallel out, Impedance 35k ohms
Input Sensitivity (Vrms Sine)
Line in 1.4 at center, 0.56 at max
Level Controls
Volume, -∞,0dB,8dB (Min, Top, Max)
EQ Controls
Thermal Limiter Advance for power consumption management
Limiter
Excursion, Thermal (RMS), Clipping
LED Indicators
Power, Excursion Limit, Thermal (RMS) Limit, Input Clip,
Enclosure Materials
Multiply 15mm Birch Plywood
Casters
4 x Locking Swivel Casters On Rear Of Cabinet
Stand Adapter
2 (1 Top, 1 Side)
UHMW Skid Glides
2 Rear
Stacking Feature
Rubber Feet and Cups (Side and Bottom)
Covering / Finish
Paint
Dimensions (DWH inches)
32.750 (37.750 including casters) x 29.750 x 47.5
Dimensions (DWH cm)
83.2 (95.8 including casters) x 75.5 x 120.6
Weight (lbs/kg)
370/168
*Specifications subject to change without notice
Spécifications
Actif ou passif
Actif
Puissance Nominale (watts)
6000 watts de programme 17000 watts de crête
SPL maximum mesuré (pondéré C, maintien maximum)
130,6 dB Cont., 142,6 dB Crête
Réponse en fréquence (Hz +/- 3dB)
28Hz-100Hz
Fréquence de coupure (Hz)
Passe-bas 50 ou 100 Hz
Configuration de l'enceinte
Bass Reflex
Configuration des haut-parleurs
Woofer BF 2x21 pouces
Driver(s) BF
Neo de 21 pouces avec bobine Tetra de 4,5 pouces
Puissance du programme BF (watts)
6000 watts en programme, 17000 watts en crête
Impédance BF (ohms)
Impédance BF 2 amplificateurs, 4 ohms par amplificateur
Protection BF
Excursion, bobine de voix thermique (RMS)
Amplificateur de puissance BF (watts)
6000 watts programme (17000 watts crête)
Type d'amplificateur BF
Classe D
Système de refroidissement
Convection
Cordon d'alimentation
Verrouillage amovible Powercon Entrée True et sortie Loop
Commutateur d'alimentation
Oui
Consommation électrique (typ/max)
1440 VA / 1920 VA
Entrées
1 XLR avec 2x XLR sortie parallèle, Impédance 35k ohms
Sensibilité d'entrée (Vrms sinus)
Entrée ligne 1,4 au centre, 0,56 au maximum
Commandes de niveau
Volume, -∞,0dB,8dB (Min, Top, Max)
Commandes d'égalisation
Limiteur thermique Advance pour la gestion de la
Limiteur
Excursion, thermique (RMS), écrêtage
Indicateurs DEL
Puissance, Limite d'excursion, Limite thermique (RMS), Clip
Matériaux du boîtier
Contreplaqué de bouleau de 15mm
Roues
4 roulettes pivotantes verrouillables à l'arrière de l'armoire
Adaptateur de support
2 (1 dessus, 1 latérale)
Glissières de protection UHMW
2 Arrière
Caractéristiques d'empilage
Pieds et coupelles en caoutchouc (côté et dessous)
Revêtement / Finition
Peinture
Dimensions (PLH pouces)
32,750 (37,750 avec les roulettes) x 29,750 x 47,5
Dimensions (PLH cm)
83,2 (95,8 avec les roulettes) x 75,5 x 120,6
Poids (livres/kg)
370/168
*Spécifications sujettes à modification sans préavis
Block Diagram SA221S
DESIGNED & MANUFA CTURED BY YORKVILLE SOUND
block-diagram-SYNERGY-SA221S-00-1v1
Output
Input
XLR
Sub
Level
50Hz
LP
AC Line
Sense
AC Line
Current Sense
Line
Current
Limit
Microcontroller
DSP
ADC DAC
HP
Output
2
3
1
2
3
1
2
3
1
1
3
2
AMP
+
-
AMP
+
-
Act.
VC
ThermX-Max
Input
Clip
Limit
Pwr
M1811-2 Parts Reference List 5/19/2021
AI-ASS
M1811-5
D1
D2
D3
LD1
LD2
PCB1
M1811B
Q1
Q2
Q3
Q4
Q5
Q6
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
R13
R14
R15
R16
R17
R18
R19
R20
R21
R22
R23
R24
R25
R26
R27
R28
R29
R30
R31
R32
R33
SNL2
W1
M1813 01 Parts Reference List 9/29/2020
REF YS # Description REF YS #
Description REF YS # Description
AI-ASS
M1813-59 SA153 INPUT
C1
8178 470P 250V 5%CAP 0603 SMT NP0
C2
8178 470P 250V 5%CAP 0603 SMT NP0
J1
4010 XLR FEML PCB MT VERT 24MM AA-SERIES
J2
4140 XLR MALE PCB MT VERT 24MM A-SERIES
J3
4140 XLR MALE PCB MT VERT 24MM A-SERIES
L1
7967 _15.0UH COIL 0805 SMT
PCB1
M1813BLANK 2_OZ 2SD 81.2 SQIN 12PER SA153
R1
6543 48R 265V RESETTABLE THERMISTOR PTC
R2
7624 W100 100R 1% 0805 SMT RES
R3
7624 W100 100R 1% 0805 SMT RES
R4
4967 W125 39K2 1% 0805 SMT RES
W1
3966 GRN 16AWG PREFUSED WIRE
W2
2357 4 CIR XH-HEADER RA 0.098IN
M1831-01 Parts Reference List 5/19/2021
REF YS # Description REF YS #
Description REF YS # Description
AI-ASS
M1831-59 SA115S/SA221S INPUT
J1
4140 XLR MALE PCB MT VERT 24MM A-SERIES
PCB1
M1831BLANK
2_OZ 2SD 46.16 SQIN 21PER SA221S
W1
2369 3 CIR PH-HEADER 2MM
M1832-01 Parts Reference List 5/19/2021
REF YS # Description REF YS #
Description REF YS # Description
AI-ASS
M1832-59 SA221S/SA115S AC INPUT
C1
5242 100N 250V 20%CAP BLK 'X2' 15MM AC
C2
5266
680N 250V 20%CAP BLK 'X2' 27MM AC
C3
5865 100N 250V 10%CAP BLK RAD POLY FLM
C4
5865 100N 250V 10%CAP BLK RAD POLY FLM
C5
5914 100U 63V 20%CAP BLK 10X13MM EL
C6
6451 __4N7 250V 20%CAP BLK 'Y' 10MM AC
C32
5629 _10U 160V 20%CAP BLK 10X13MM EL
C33
5260 _22U 50V 20%CAP T&R RAD .2EL
C34
5959 _10U 450V 20%CAP BLK EL
D1
6775 BRIDGE 25A 600V WIRE LEAD SIP
D2
6775 BRIDGE 25A 600V WIRE LEAD SIP
D3
6438 1N4007 1000V 1A0 DIODE T&R
D4
6438 1N4007 1000V 1A0 DIODE T&R
D11
6438 1N4007 1000V 1A0 DIODE T&R
D12
6438 1N4007 1000V 1A0 DIODE T&R
D13
6438 1N4007 1000V 1A0 DIODE T&R
K1
3696 RELAY 1C 02AMP DC24 006MA PC-S
K2
3019 RELAY 1C 30AMP DC110 08MA PC-C
L1
3817 _1.5MH COIL INPUT COM MODE
PCB
M1832BLANK 3_OZ 2SD 53SQIN 1PER SA221S AC IN
Q3
6854 2N6517 350V TO92 NPN TRAN TA
Q4
5101 BC550C TO92 NPN TRAN T&R TB
R1
2504 __2R 25% 35A INRSH CURR LIM 36MM
R2
2504 __2R 25% 35A INRSH CURR LIM 36MM
R3
2504 __2R 25% 35A INRSH CURR LIM 36MM
R4
2504 __2R 25% 35A INRSH CURR LIM 36MM
R5
4621 W500 470R 5% T&R RES
R6
4621 W500 470R 5% T&R RES
R12
4851 W250 120K 5% T&R RES
R13
4842 W250 330K 5% T&R RES
R14
4894 W250 130K 5% T&R RES
R15
4894 W250 130K 5% T&R RES
R16
4841 W250 220K 5% T&R RES
R17
4838 W250 100K 5% T&R RES
R74
4683 1W00 1K8 5% T&R RES
SNL1
8370 1 MIL POLYIMIDE LABEL, 1" X .380"
T1
1233 CURRENT XMFR SML PC MNT EI-25
W1
4263 2 CIR HDR VERT HI CURR 0.224IN SPC
W2
4056 2 CIR XH-HEADER 0.098IN
W3
4147 6 PIN POWER PIN HEADER MALE POLZED
W4
4146 3 PIN POWER PIN HEADER MALE POLZED
W5
4163 5 PIN POWER PIN HEADER MALE POLZED
W6
4147 6 PIN POWER PIN HEADER MALE POLZED
W7
4151 4 PIN POWER PIN HEADER MALE POLZED
W8
4146 3 PIN POWER PIN HEADER MALE POLZED
W9
4151 4 PIN POWER PIN HEADER MALE POLZED
W10
4151 4 PIN POWER PIN HEADER MALE POLZED
W11
4151 4 PIN POWER PIN HEADER MALE POLZED
W12
4151 4 PIN POWER PIN HEADER MALE POLZED
W13
4263 2 CIR HDR VERT HI CURR 0.224IN SPC
M1833-02 Parts Reference List 5/19/2021
REF YS # Description REF YS #
Description REF YS # Description REF YS # Description REF
YS #
Description
AI-SUB
M1833-59 SA115S/SA221S AMP/SUPPLY PCB AI
D3
6300 MURA260T3 600V 2A DIO 403D SMT
R12
5068 W125 187K 0.1% 0805 SMT RES
R225
7930 W250 22R 5% 1206 SMT RES
BLANK
M1833BLANK 3_OZ 2SD 83.6 SQIN 01PER SA115S/221
D4
8814 ES1J 600V 1A0 DO214AC SMT SMA
R13
5068 W125 187K 0.1% 0805 SMT RES
R226
7628 W100 15K0 1% 0805 SMT RES
C1
5982 150P 1000V 5%CAP 1206 SMT C0G
D5
8814 ES1J 600V 1A0 DO214AC SMT SMA
R14
5068 W125 187K 0.1% 0805 SMT RES
R227
7622 W100 1M0 1% 0805 SMT RES
C2
7809 _10U 16V 20%CAP 5X5.4 SMT NP
D6
7832 MM3Z18VT1G 18V0 0W2 5% SMT ZEN
R15
5000 W125 140K 1% 0805 SMT RES
R229
7852 W250 10R 5% 1206 SMT RES
C3
5949 __3U3 140AC10%CAP BLK RAD POLYP FLM
D7
7742 B0540 SOD123 SMT SCHTKY
R16
7651 W250 1M0 1% 1206 SMT RES
R231
7621 W100 1K0 1% 0805 SMT RES
C4
5949 __3U3 140AC10%CAP BLK RAD POLYP FLM
D8
7742 B0540 SOD123 SMT SCHTKY
R17
7651 W250 1M0 1% 1206 SMT RES
R232
7621 W100 1K0 1% 0805 SMT RES
C5
7734 __1U0 50V 10%CAP 1206 SMT CER
D9
7742 B0540 SOD123 SMT SCHTKY
R18
7651 W250 1M0 1% 1206 SMT RES
R233
7680 W100 6K98 1% 0805 SMT RES
C6
7697 _22U 16V 5%CAP 5X5.5 SMT ELC
D10
7742 B0540 SOD123 SMT SCHTKY
R19
8274 W125 6K20 1% 0805 SMT RES
R234
7630 W100 182K 1% 0805 SMT RES
C7
5979 100N 50V 5%CAP 0805 SMT X7R
D11
7832 MM3Z18VT1G 18V0 0W2 5% SMT ZEN
R20
7863 W125 33K 5% 0805 SMT RES
R236
7680 W100 6K98 1% 0805 SMT RES
C8
7880 _47U 35V 20%CAP 6.3MM SMT ELE
D12
8109 BAV21WS 200V 0A2 SOD323 SMT
R21
8274 W125 6K20 1% 0805 SMT RES
R237
7802 1W00 1R0 5% 2512 SMT RES
C9
7735 __4U7 50V 10%CAP 1210 SMT CER
D13
8109 BAV21WS 200V 0A2 SOD323 SMT
R22
7622 W100 1M0 1% 0805 SMT RES
R238
5084 W125 33R 5% 0805 SMT RES
C10
5217
_22N 560V 10%CAP BLK RAD POLY FLM
D14
7700 5237B 8V2 0W2 SOT-23 SMT ZEN
R24
7860 W125 4K7 5% 0805 SMT RES
R240
7856 W125 470R 5% 0805 SMT RES
C11
7735 __4U7 50V 10%CAP 1210 SMT CER
D15
7750 CDSF4148 75V 0A15 1005 SMT
R25
7625 W100 10K0 1% 0805 SMT RES
R242
5079 2W00 0R02 1% OARS SMT RES
C12
5923 3300U 250V 10%CAP BLK 40X80MM 4PS
D16
7700 5237B 8V2 0W2 SOT-23 SMT ZEN
R26
7645 W100 475K 1% 0805 SMT RES
R243
5079 2W00 0R02 1% OARS SMT RES
C13
5923 3300U 250V 10%CAP BLK 40X80MM 4PS
D17
7700 5237B 8V2 0W2 SOT-23 SMT ZEN
R27
7645 W100 475K 1% 0805 SMT RES
R244
5070 2W00 0R05 1% OARS SMT RES
C14
5923 3300U 250V 10%CAP BLK 40X80MM 4PS
D18
7619 BZX84C43 43V0 0W3 5% SMT ZEN
R28
7645 W100 475K 1% 0805 SMT RES
R247
7860 W125 4K7 5% 0805 SMT RES
C15
5923 3300U 250V 10%CAP BLK 40X80MM 4PS
D19
7750 CDSF4148 75V 0A15 1005 SMT
R29
7651 W250 1M0 1% 1206 SMT RES
R249
7852 W250 10R 5% 1206 SMT RES
C16
5979 100N 50V 5%CAP 0805 SMT X7R
D20
6300 MURA260T3 600V 2A DIO 403D SMT
R30
5082 W125 1K27 1% 0805 SMT RES
R251
7930 W250 22R 5% 1206 SMT RES
C17
7697 _22U 16V 5%CAP 5X5.5 SMT ELC
D23
7832 MM3Z18VT1G 18V0 0W2 5% SMT ZEN
R31
7645 W100 475K 1% 0805 SMT RES
R255
7703 W125 82K5 1% 0805 SMT RES
C18
8096 470N 100V 10%CAP 1206 SMT X7R
D24
7832 MM3Z18VT1G 18V0 0W2 5% SMT ZEN
R32
7645 W100 475K 1% 0805 SMT RES
R256
7703 W125 82K5 1% 0805 SMT RES
C19
7603 680P 50V 5%CAP 0805 SMT C0G
D25
7832 MM3Z18VT1G 18V0 0W2 5% SMT ZEN
R33
7645 W100 475K 1% 0805 SMT RES
R258
7634 W100 20K5 1% 0805 SMT RES
C20
7601 220N 50V 10%CAP 1206 SMT X7R
D28
7619 BZX84C43 43V0 0W3 5% SMT ZEN
R34
7645 W100 475K 1% 0805 SMT RES
R259
7630 W100 182K 1% 0805 SMT RES
C21
7875 100N 100V 10%CAP 1206 SMT X7R
D204
8814 ES1J 600V 1A0 DO214AC SMT SMA
R35
7863 W125 33K 5% 0805 SMT RES
R260
4931 470K 5% THERMISTOR NTC 0805 SMT
C22
7875 100N 100V 10%CAP 1206 SMT X7R
D205
8814 ES1J 600V 1A0 DO214AC SMT SMA
R36
7645 W100 475K 1% 0805 SMT RES
R261
7686 W100 274K 1% 0805 SMT RES
C23
6011 _33N 630V 5%CAP 1210 SMT COG
D213
7617 BZX84C15LT1 15V0 0W225 ZEN SOT23
R37
7645 W100 475K 1% 0805 SMT RES
R262
7622 W100 1M0 1% 0805 SMT RES
C24
7735 __4U7 50V 10%CAP 1210 SMT CER
D214
7750 CDSF4148 75V 0A15 1005 SMT
R38
7676 W100 2K0 1% 0805 SMT RES
R268
8189 W125 4K02 0.1% 0805 SMT RES
C25
7735 __4U7 50V 10%CAP 1210 SMT CER
F5
5136 FUSE 1A25 500VDC SMT F4319
R39
7622 W100 1M0 1% 0805 SMT RES
SNL1
8370 1 MIL POLYIMIDE LABEL, 1" X .380"
C26
7735 __4U7 50V 10%CAP 1210 SMT CER
F6
5136 FUSE 1A25 500VDC SMT F4319
R40
7821 W125 10R0 1% 0805 SMT RES
T4
8188 XF3955 GATE DRIVE XFMR SMT
C27
6011 _33N 630V 5%CAP 1210 SMT COG
HS1
4233 22X17X2MM ALN CERAMIC TO247 INSUL
R41
7621 W100 1K0 1% 0805 SMT RES
T5
8188 XF3955 GATE DRIVE XFMR SMT
C28
6011 _33N 630V 5%CAP 1210 SMT COG
HS2
4233 22X17X2MM ALN CERAMIC TO247 INSUL
R42
7645 W100 475K 1% 0805 SMT RES
U1
8158 LNK306G OFFLINE SWITCH SMT SMD8B
C29
6011 _33N 630V 5%CAP 1210 SMT COG
HS3
Z1740 M1806 HEAT SPREADER
R43
7645 W100 475K 1% 0805 SMT RES
U2
7661 LM393D DUAL COMPARATOR SMT SO-8
C30
7875 100N 100V 10%CAP 1206 SMT X7R
HW1
8800 6-32 KEPS NUT ZINC
R44
7645 W100 475K 1% 0805 SMT RES
U3
7949 ZXGD3002E6 GATE DRVR 9A SMT SOT326
C31
7735 __4U7 50V 10%CAP 1210 SMT CER
HW2
8902 4-40X3/4 PAN PHILIPS MS TBZ
R45
7645 W100 475K 1% 0805 SMT RES
U4
7949 ZXGD3002E6 GATE DRVR 9A SMT SOT326
C32
6011 _33N 630V 5%CAP 1210 SMT COG
HW4
8485 #6 SPLIT WASHER ZINC
R46
7645 W100 475K 1% 0805 SMT RES
U5
7836 TLC555 TIMER SMT SO8 IC
C33
6011 _33N 630V 5%CAP 1210 SMT COG
HW6
8742 4-40X3/8 PAN PH TAPTITE BO&W
R47
5096 W125 28K7 1% 0805 SMT RES
U8
7987 UCC25600 RES MODE CTRL SMT SO8
C34
6011 _33N 630V 5%CAP 1210 SMT COG
HW7
8835 6-32X1/2 PAN QUAD MS TIN PLATE
R48
7645 W100 475K 1% 0805 SMT RES
U200
6668 LTV-8141S ACINPUT OPTOCOUPLER SMT
C35
6011 _33N 630V 5%CAP 1210 SMT COG
HW8
8835 6-32X1/2 PAN QUAD MS TIN PLATE
R49
7688 W125 4M7 5% 0805 SMT RES
U201
7851 LM311 COMPARATOR IC SMT SO-8
C36
6011 _33N 630V 5%CAP 1210 SMT COG
HW9
8800 6-32 KEPS NUT ZINC
R50
7622 W100 1M0 1% 0805 SMT RES
U202
7851 LM311 COMPARATOR IC SMT SO-8
C37
7875 100N 100V 10%CAP 1206 SMT X7R
HW10
8902 4-40X3/4 PAN PHILIPS MS TBZ
R51
7626 W125 100K0 1% 0805 SMT RES
U203
6686 IRS21844SPBF IC HILO FET DRVR SO14
C38
7738 _10U 16V 10%CAP 1206 SMT X7R
HW11
4124 SILPAD 1500ST 1.100 X0.820 BERQUIST
R53
8008 W250 10K 5% ANTISURGE 0805 SMT RES
U204
7817 33078 DUAL OPAMP SMT SO-8
C39
7738 _10U 16V 10%CAP 1206 SMT X7R
HW12
4249 1POS XSISTOR SPRING
R54
7622 W100 1M0 1% 0805 SMT RES
U205
7817 33078 DUAL OPAMP SMT SO-8
C40
7875 100N 100V 10%CAP 1206 SMT X7R
HW13
8701 4-40 KEPS NUT ZINC
R55
5088 W125 49K9 1% 0805 SMT RES
U206
8163 TL331 COMPARATOR IC SMT SOT235
C41
7693 __1N 50V 5%CAP 0805 SMT NPO
HW14
8701 4-40 KEPS NUT ZINC
R56
5088 W125 49K9 1% 0805 SMT RES
W1
3538 24 PIN BREAKAWAY LOCK .156
C42
7693 __1N 50V 5%CAP 0805 SMT NPO
HW15
8832 6-32X1/4 PAN PH TAPTITE JS500
R57
5088 W125 49K9 1% 0805 SMT RES
W2
3538 24 PIN BREAKAWAY LOCK .156
C200
5979 100N 50V 5%CAP 0805 SMT X7R
HW17
8485 #6 SPLIT WASHER ZINC
R58
5088
W125 49K9 1% 0805 SMT RES
W3
4146 3 PIN POWER PIN HEADER MALE POLZED
C202
5979 100N 50V 5%CAP 0805 SMT X7R
L1
8101 120.0UH COIL A34 1R6 SMT
R59
4703 2W00 2R 5% T&R RES
W4
4163 5 PIN POWER PIN HEADER MALE POLZED
C203
5979 100N 50V 5%CAP 0805 SMT X7R
L2
7974 1000UH 10% COIL 12MM SMT
R60
4703 2W00 2R 5% T&R RES
W5
3538 24 PIN BREAKAWAY LOCK .156
C204
5979 100N 50V 5%CAP 0805 SMT X7R
L3
8101 120.0UH COIL A34 1R6 SMT
R61
7654 W250 619K 1% 1206 SMT RES
W201
2328 8 CIR XH-HEADER 0.098IN
C205
5979 100N 50V 5%CAP 0805 SMT X7R
L4
2919 __0.18UH 20% COIL 11MM SMT
R62
7654 W250 619K 1% 1206 SMT RES
ZD200
7832 MM3Z18VT1G 18V0 0W2 5% SMT ZEN
C206
5979 100N 50V 5%CAP 0805 SMT X7R
L7
7967 _15.0UH COIL 0805 SMT
R63
7654 W250 619K 1% 1206 SMT RES
C207
5979 100N 50V 5%CAP 0805 SMT X7R
L200
6699 _453UH CHOKE 91T14.5AWG/79912CORE
R64
7864 W125 100K 5% 0805 SMT RES
C208
5979 100N 50V 5%CAP 0805 SMT X7R
Q1
7915 T810-600G-TR 8A TRIAC D2PAK SMT
R65
7864 W125 100K 5% 0805 SMT RES
C209
5979 100N 50V 5%CAP 0805 SMT X7R
Q2
7720 TL431A 3 TERM ADJ VREG SMT SOT-23
R66
7864 W125 100K 5% 0805 SMT RES
C210
5979 100N 50V 5%CAP 0805 SMT X7R
Q3
5190 MBS4992 TO92 8V5 DIAC T&R
R67
7645 W100 475K 1% 0805 SMT RES
C211
5979 100N 50V 5%CAP 0805 SMT X7R
Q4
6730 IRF830 TO220 NCH MFET TN
R70
5082 W125 1K27 1% 0805 SMT RES
C212
5979 100N 50V 5%CAP 0805 SMT X7R
Q5
6847 MMBTA42 NPN SOT-23 SMT
R71
7645 W100 475K 1% 0805 SMT RES
C213
7603 680P 50V 5%CAP 0805 SMT C0G
Q6
6847 MMBTA42 NPN SOT-23 SMT
R72
7621 W100 1K0 1% 0805 SMT RES
C216
7693 __1N 50V 5%CAP 0805 SMT NPO
Q7
8165 MMBTA92 PNP SOT-23 SMT
R73
5095 W250 33R 5% 1206 SMT RES
C217
7871 470P 50V 5%CAP 0603 SMT NPO
Q8
7986 2N7002 NCH FET SOT-23 SMT T&R
R74
5095 W250 33R 5% 1206 SMT RES
C218
7693 __1N 50V 5%CAP 0805 SMT NPO
Q9
6847 MMBTA42 NPN SOT-23 SMT
R75
7864 W125 100K 5% 0805 SMT RES
C219
5972 680N 400V 5%CAP BLK RAD POLY FLM
Q10
8165 MMBTA92 PNP SOT-23 SMT
R76
7645 W100 475K 1% 0805 SMT RES
C220
7601 220N 50V 10%CAP 1206 SMT X7R
Q11
6977 FDT3612 NCH MFET SOT-223 SMT
R77
7645 W100 475K 1% 0805 SMT RES
C221
7875 100N 100V 10%CAP 1206 SMT X7R
Q12
6977 FDT3612 NCH MFET SOT-223 SMT
R78
7645 W100 475K 1% 0805 SMT RES
C222
5986 _10U 600VDC 5%CAP BLK MPOLYP FLM
Q13
7846 MC7815BDTG POS REG SMT DPAK3
R79
7864 W125 100K 5% 0805 SMT RES
C223
5986 _10U 600VDC 5%CAP BLK MPOLYP FLM
Q14
6847 MMBTA42 NPN SOT-23 SMT
R80
7864 W125 100K 5% 0805 SMT RES
C224
7769 __1U 50V 20%CAP 4.3X3.9 SMT ELC
Q15
6847 MMBTA42 NPN SOT-23 SMT
R81
7622 W100 1M0 1% 0805 SMT RES
C225
7871 470P 50V 5%CAP 0603 SMT NPO
Q203
2321 IKW75N65EH5 T0247 NPN 75A IGB3
R200
7821 W125 10R0 1% 0805 SMT RES
C226
8176 _47N 100V 10%CAP 1206 SMT X7R
Q204
8165 MMBTA92 PNP SOT-23 SMT
R201
7761 W100 12K1 1% 0603 SMT RES
C227
5979 100N 50V 5%CAP 0805 SMT X7R
Q205
2321 IKW75N65EH5 T0247 NPN 75A IGB3
R202
7821 W125 10R0 1% 0805 SMT RES
C228
5972 680N 400V 5%CAP BLK RAD POLY FLM
R1
5068 W125 187K 0.1% 0805 SMT RES
R203
7625 W100 10K0 1% 0805 SMT RES
C229
5225 470P 1600V 20%CAP POLYPROP BULK
R2
7852 W250 10R 5% 1206 SMT RES
R204
7761 W100 12K1 1% 0603 SMT RES
C230
7813 _47P 50V 5%CAP 0805 SMT NPO
R3
5096 W125 28K7 1% 0805 SMT RES
R210
7634 W100 20K5 1% 0805 SMT RES
C231
5979 100N 50V 5%CAP 0805 SMT X7R
R4
8137 W125 1K62 1% 0805 SMT RES
R214
7860 W125 4K7 5% 0805 SMT RES
C232
7917 _33U 25V 20%CAP 6.3X5.5 SMT EL
R5
7852 W250 10R 5% 1206 SMT RES
R215
7824 W125 47K5 1% 0805 SMT RES
C233
5979 100N 50V 5%CAP 0805 SMT X7R
R6
7628 W100 15K0 1% 0805 SMT RES
R218
8321 W125 8K66 1% 0805 SMT RES
C234
5979 100N 50V 5%CAP 0805 SMT X7R
R7
7680 W100 6K98 1% 0805 SMT RES
R219
7673 W100 475R 1% 0805 SMT RES
C235
7969 _10U 16V 20%CAP 0805 SMT X5R
R8
8189 W125 4K02 0.1% 0805 SMT RES
R221
7856 W125 470R 5% 0805 SMT RES
C242
7738 _10U 16V 10%CAP 1206 SMT X7R
R9
5084 W125 33R 5% 0805 SMT RES
R222
7625 W100 10K0 1% 0805 SMT RES
D1
8814 ES1J 600V 1A0 DO214AC SMT SMA
R10
5084 W125 33R 5% 0805 SMT RES
R223
7680 W100 6K98 1% 0805 SMT RES
D2
6300 MURA260T3 600V 2A DIO 403D SMT
R11
5068 W125 187K 0.1% 0805 SMT RES
R224
7854 W125 47R 5% 0805 SMT RES
M1834-01 Parts Reference List 5/19/2021
REF YS #
Description REF YS # Description REF YS # Description
C1
5911 2700U 250V 20%CAP BLK 40X63MM 4PS
C2
5911 2700U 250V 20%CAP BLK 40X63MM 4PS
C5
5911 2700U 250V 20%CAP BLK 40X63MM 4PS
C6
5911 2700U 250V 20%CAP BLK 40X63MM 4PS
C7
5911
2700U 250V 20%CAP BLK 40X63MM 4PS
C8
5911 2700U 250V 20%CAP BLK 40X63MM 4PS
C9
5911 2700U 250V 20%CAP BLK 40X63MM 4PS
C10
5911 2700U 250V 20%CAP BLK 40X63MM 4PS
F1
2499 1.25 AMP SLO-BLO 500V AXIAL FUSE
F2
2499 1.25 AMP SLO-BLO 500V AXIAL FUSE
F3
3477 5AG FUSE CLIP CARTRIDGE 30A PCB
F4
3477
5AG FUSE CLIP CARTRIDGE 30A PCB
F5
3477 5AG FUSE CLIP CARTRIDGE 30A PCB
F6
3477 5AG FUSE CLIP CARTRIDGE 30A PCB
PCB
M1834BLANK 3_OZ 2SD 58.7 SQIN 01PER SA221S CAP
SNL1
8370 1 MIL POLYIMIDE LABEL, 1" X .380"
W1
4194 2X2 3 MM MICRO MATE-N-LOK VRT
W2
4146 3 PIN POWER PIN HEADER MALE POLZED
W4
4147 6 PIN POWER PIN HEADER MALE POLZED
W5
4151 4 PIN POWER PIN HEADER MALE POLZED
M1837-01 Parts Reference List 5/19/2021
REF YS # Description REF YS #
Description REF YS # Description
PCB
M1837BLANK 3_OZ 2SD 60.9SQIN 6PER SYNERGY CURR
R74
4683 1W00 1K8 5% T&R RES
SNL1
8370 1 MIL POLYIMIDE LABEL, 1" X .380"
T1
1233 CURRENT XMFR SML PC MNT EI-25
W2
4056 2 CIR XH-HEADER 0.098IN
W10
4151 4 PIN POWER PIN HEADER MALE POLZED
W11
4151 4 PIN POWER PIN HEADER MALE POLZED
W12
4151 4 PIN POWER PIN HEADER MALE POLZED
W13
4263 2 CIR HDR VERT HI CURR 0.224IN SPC
M1950-03 Parts Reference List 5/19/2021
REF YS # Description REF YS #
Description REF YS # Description
AI-ASS
M1950-59 SA221S INPUT DSP BOARD 1OZ
LD6
7031
GRN LED 2V8 20MA 1206 SMT
S1
3522 DPDT MINI PC VERT SNP ALT
C1
5979 100N 50V 5%CAP 0805 SMT X7R
P4
2339 _10K B LIN 12MM DUAL 21DET P34
S4
4189 DP4T NONSHORTING VERT ROT SWT
C2
7871 470P 50V 5%CAP 0603 SMT NPO
PCB1
M1950BLANK 1_OZ 2SD 60.67SQIN 3PER SA221S INP
SNL2
8372 1 MIL POLYIMIDE LABEL,.375" X .375"
C3
7878 __1U 25V 20%CAP 1206 SMT X7R
Q1
7837 MMBT5401 PNP SOT-23 SMT
TP1
8002 TEST POINT MINIATURE SMT
C4
5979 100N 50V 5%CAP 0805 SMT X7R
Q2
7837 MMBT5401 PNP SOT-23 SMT
TP7
8002 TEST POINT MINIATURE SMT
C5
5979 100N 50V 5%CAP 0805 SMT X7R
Q3
6847
MMBTA42 NPN SOT-23 SMT
TP8
8002 TEST POINT MINIATURE SMT
C6
5669 470U 6V3 20%CAP RAD EL T&R
R1
7951 W125 750R 1% 0805 SMT RES
TP9
8002 TEST POINT MINIATURE SMT
C7
5945 _10U 63V 20%CAP T&R RAD .2EL
R2
7638 W100 3K74 1% 0805 SMT RES
TP10
8002 TEST POINT MINIATURE SMT
C8
5945 _10U 63V 20%CAP T&R RAD .2EL
R3
7675 W125 1K21 1% 0805 SMT RES
TP12
8002 TEST POINT MINIATURE SMT
C9
5233 330N 63V 5%CAP T&R RAD .2FLM
R4
8027
W125 37K4 1% 0805 SMT RES
TP13
8002 TEST POINT MINIATURE SMT
C10
5233 330N 63V 5%CAP T&R RAD .2FLM
R5
5066 W125 22K1 1% 0805 SMT RES
TP14
8002 TEST POINT MINIATURE SMT
C11
5212 100N 100V 5%CAP T&R RAD .2FLM
R6
7928 W125 10K00 0.1% 0805 SMT RES
TP15
8002 TEST POINT MINIATURE SMT
C12
5979 100N 50V 5%CAP 0805 SMT X7R
R7
7820 W100 499R 1% 0805 SMT RES
U1
7817 33078 DUAL OPAMP SMT SO-8
C13
5979 100N 50V 5%CAP 0805 SMT X7R
R8
7951 W125 750R 1% 0805 SMT RES
U2
7719
MC33063ADR BUCK/BOOST INV IC SO8
C14
5979 100N 50V 5%CAP 0805 SMT X7R
R9
7820
W100 499R 1% 0805 SMT RES
U3
6670 AK4558 32BIT CODEC SMT QFN28
C15
5979 100N 50V 5%CAP 0805 SMT X7R
R10
7858 W125 1K5 5% 0805 SMT RES
U4
6667 MK10DN512VLK10 100MHZ MCU IC LQFP80
C16
5212 100N 100V 5%CAP T&R RAD .2FLM
R11
7820 W100 499R 1% 0805 SMT RES
U5
7012 LP2950-33 LDRP TO92 FIXED 3V3 REG
C17
7738 _10U 16V 10%CAP 1206 SMT X7R
R12
7928 W125 10K00 0.1% 0805 SMT RES
U6
7012 LP2950-33 LDRP TO92 FIXED 3V3 REG
C18
7969 _10U 16V 20%CAP 0805 SMT X5R
R13
7708 W100 200R 1% 0805 SMT RES
U7
7669
TL072 DUAL OPAMP SMT SO-8
C19
5979 100N 50V 5%CAP 0805 SMT X7R
R14
7951
W125 750R 1% 0805 SMT RES
U8
7669 TL072 DUAL OPAMP SMT SO-8
C20
5979 100N 50V 5%CAP 0805 SMT X7R
R15
7849 W250 0R27 5% 1206 SMT RES
U9
7669 TL072 DUAL OPAMP SMT SO-8
C21
5979 100N 50V 5%CAP 0805 SMT X7R
R16
7676 W100 2K0 1% 0805 SMT RES
W1
2357 4 CIR XH-HEADER RA 0.098IN
C22
7878 __1U 25V 20%CAP 1206 SMT X7R
R17
7676 W100 2K0 1% 0805 SMT RES
W2
2328 8 CIR XH-HEADER 0.098IN
C23
5979 100N 50V 5%CAP 0805 SMT X7R
R18
7624 W100 100R 1% 0805 SMT RES
W3
4183
10 CIR DUAL ROW HDR 0.05 SPC SMT
C24
7878 __1U 25V 20%CAP 1206 SMT X7R
R19
7781 W063 49R9 1% 0603 SMT RES
W4
2328 8 CIR XH-HEADER 0.098IN
C25
5979 100N 50V 5%CAP 0805 SMT X7R
R20
7854 W125 47R 5% 0805 SMT RES
W6
2369 3 CIR PH-HEADER 2MM
C26
7878 __1U 25V 20%CAP 1206 SMT X7R
R21
7624
W100 100R 1% 0805 SMT RES
W8
4056 2 CIR XH-HEADER 0.098IN
C27
7878 __1U 25V 20%CAP 1206 SMT X7R
R22
8135 W125 47K 5% 0805 SMT RES
ZD1
7832 MM3Z18VT1G 18V0 0W2 5% SMT ZEN
C28
5979 100N 50V 5%CAP 0805 SMT X7R
R23
8135 W125 47K 5% 0805 SMT RES
ZD2
7832 MM3Z18VT1G 18V0 0W2 5% SMT ZEN
C29
5979 100N 50V 5%CAP 0805 SMT X7R
R24
7928 W125 10K00 0.1% 0805 SMT RES
C30
5979 100N 50V 5%CAP 0805 SMT X7R
R25
7928 W125 10K00 0.1% 0805 SMT RES
C31
5979 100N 50V 5%CAP 0805 SMT X7R
R26
7928
W125 10K00 0.1% 0805 SMT RES
C32
7871 470P 50V 5%CAP 0603 SMT NPO
R27
7820 W100 499R 1% 0805 SMT RES
C33
7871 470P 50V 5%CAP 0603 SMT NPO
R28
7670 W125 47R5 1% 0805 SMT RES
C34
5979 100N 50V 5%CAP 0805 SMT X7R
R29
7860 W125 4K7 5% 0805 SMT RES
C35
7878 __1U 25V 20%CAP 1206 SMT X7R
R30
7632 W100 2K32 1% 0805 SMT RES
C36
7878 __1U 25V 20%CAP 1206 SMT X7R
R31
7821 W125 10R0 1% 0805 SMT RES
C37
7871 470P 50V 5%CAP 0603 SMT NPO
R32
7928 W125 10K00 0.1% 0805 SMT RES
C38
5979 100N 50V 5%CAP 0805 SMT X7R
R33
7624 W100 100R 1% 0805 SMT RES
C39
5979 100N 50V 5%CAP 0805 SMT X7R
R35
7671 W125 249R0 1% 0805 SMT RES
C40
7927 100P 50V 10%CAP 0805 SMT NPO
R36
7671 W125 249R0 1% 0805 SMT RES
C41
5212 100N 100V 5%CAP T&R RAD .2FLM
R37
7680 W100 6K98 1% 0805 SMT RES
C42
5212 100N 100V 5%CAP T&R RAD .2FLM
R38
7624 W100 100R 1% 0805 SMT RES
C43
8253 20P 100V 5%CAP 0805 SMT NPO
R39
7670 W125 47R5 1% 0805 SMT RES
C44
8253 20P 100V 5%CAP 0805 SMT NPO
R40
7745 W125 0R 5% 0805 SMT RES
C45
8253 20P 100V 5%CAP 0805 SMT NPO
R41
8027 W125 37K4 1% 0805 SMT RES
C46
7878 __1U 25V 20%CAP 1206 SMT X7R
R42
7821 W125 10R0 1% 0805 SMT RES
C47
5979 100N 50V 5%CAP 0805 SMT X7R
R44
7860 W125 4K7 5% 0805 SMT RES
C48
7738 _10U 16V 10%CAP 1206 SMT X7R
R45
5084
W125 33R 5% 0805 SMT RES
C49
7738 _10U 16V 10%CAP 1206 SMT X7R
R46
5084 W125 33R 5% 0805 SMT RES
C50
7738 _10U 16V 10%CAP 1206 SMT X7R
R47
8189 W125 4K02 0.1% 0805 SMT RES
C51
7927 100P 50V 10%CAP 0805 SMT NPO
R48
7951 W125 750R 1% 0805 SMT RES
C52
7927 100P 50V 10%CAP 0805 SMT NPO
R49
7951 W125 750R 1% 0805 SMT RES
C55
7811 100U 25V 20%CAP 8X5.4 SMT ELE
R51
7854
W125 47R 5% 0805 SMT RES
C134
5979 100N 50V 5%CAP 0805 SMT X7R
R52
7857 W125 560R 5% 0805 SMT RES
C135
5979 100N 50V 5%CAP 0805 SMT X7R
R53
7676 W100 2K0 1% 0805 SMT RES
D1
6657 B160-E3 60V 1A0 SCH DO214AC SMT
R54
8189 W125 4K02 0.1% 0805 SMT RES
D2
7750 CDSF4148 75V 0A15 1005 SMT
R55
7857 W125 560R 5% 0805 SMT RES
D3
7750 CDSF4148 75V 0A15 1005 SMT
R56
7708
W100 200R 1% 0805 SMT RES
D4
6657 B160-E3 60V 1A0 SCH DO214AC SMT
R57
7676 W100 2K0 1% 0805 SMT RES
D5
7832 MM3Z18VT1G 18V0 0W2 5% SMT ZEN
R58
5068 W125 187K 0.1% 0805 SMT RES
D6
7750 CDSF4148 75V 0A15 1005 SMT
R59
5068 W125 187K 0.1% 0805 SMT RES
D7
7750 CDSF4148 75V 0A15 1005 SMT
R62
8189 W125 4K02 0.1% 0805 SMT RES
D10
7750 CDSF4148 75V 0A15 1005 SMT
R65
8189
W125 4K02 0.1% 0805 SMT RES
D11
7750 CDSF4148 75V 0A15 1005 SMT
R66
7928 W125 10K00 0.1% 0805 SMT RES
D12
7750 CDSF4148 75V 0A15 1005 SMT
R67
7928 W125 10K00 0.1% 0805 SMT RES
D39
7750 CDSF4148 75V 0A15 1005 SMT
R68
7740 W125 698R 1% 0805 SMT RES
D40
7750 CDSF4148 75V 0A15 1005 SMT
R69
8135 W125 47K 5% 0805 SMT RES
K1
3700 RELAY 2C 01AMP DC24 015MA PC-S
R70
8135 W125 47K 5% 0805 SMT RES
L2
7967 _15.0UH COIL 0805 SMT
R71
5084 W125 33R 5% 0805 SMT RES
L3
8152 220UH COIL 10X10MM SMT
R72
8027 W125 37K4 1% 0805 SMT RES
L6
7941 __8.2UH COIL 1210 SMT
R73
7676 W100 2K0 1% 0805 SMT RES
L7
7941 __8.2UH COIL 1210 SMT
R75
7928 W125 10K00 0.1% 0805 SMT RES
L10
7967 _15.0UH COIL 0805 SMT
R76
7680 W100 6K98 1% 0805 SMT RES
L11
7967 _15.0UH COIL 0805 SMT
R107
5066 W125 22K1 1% 0805 SMT RES
L12
7967 _15.0UH COIL 0805 SMT
R165
5067 W125 31K6 0.1% 0805 SMT RES
LD1
7031 GRN LED 2V8 20MA 1206 SMT
R176
7637 W125 3K32 1% 0805 SMT RES
LD2
7032 YEL LED 1V7 20MA 1206 SMT
R177
7864 W125 100K 5% 0805 SMT RES
LD3
7033 RED LED 1V5 20MA 1206 SMT
R178
7898 W125 1K02 0.1% 0805 SMT RES
LD4
7032 YEL LED 1V7 20MA 1206 SMT
R181
5067
W125 31K6 0.1% 0805 SMT RES
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
K K
J J
I I
H H
G G
F F
E E
D D
C C
B B
A A
Product(s):
M1811 1 2
Sheet OfPCB#: Rev#:
V02
Short Description Of The ProductDescription:
SA315S
Yorkville Sound Ltd.
550 Granite Court
Pickering, ON
Canada L1W 3Y8
www.yorkville.com
EML Rev#:
XX
Discharge_Circuit.SchDocModified: File:2019-03-20 Tmp Rev: V031
GND
TO CAP BOARD
CAPACITOR DISCHARGE CIRCUIT
1
4
W1:1
2
4
W1:2
3
4
W1:3
4
4
W1:4
5
4
W1:5
SOT-23
MMBTA42
6847
Q5
SOT-23
MMBTA42
6847
Q4
SOT-23
MMBTA92
8165
Q3
IRFR825
DPAK3
6834
G
D
S
Q2
IRFR825
DPAK3
6834
G
D
S
Q1
W250
100R
1206
R9
W250
100R
1206
R29
W250
100R
1206
R7
W250
100R
1206
R8
W100
2K74
0805
R12
W100
221R
0805
R15
W100
475K
0805
R2
W100
475K
0805
R5
W100
475K
0805
R6
W100
475K
0805
R11
W100
475K
0805
R14
W100
475K
0805
R13
W100
475K
0805
R16
W100
475K
0805
R1
W100
475K
0805
R4
W100
475K
0805
R3
DO-214AC
18V
D3
RED
DISCHARGE
7033
LD1
W125
330R0
0805
R17
D1005
CDSF4148
D2
SILENT
SILENT
SOT-23
8V2
D1
GND
SILENT
Hi+
Hi-
Hi-
Hi+
1W00
0R
2512
R19
10K
W063
R18
10K
RED
PWR
7033
LD2
W750
0R
2010
R20
LEG
W125
1K800
0805
R24
W100
1M0
0805
R25
W250
680R
1206
R21
W250
680R
1206
R22
IRFR825
DPAK3
6834
G
D
S
Q6
W250
100R
1206
R10
W250
100R
1206
R30
W250
680R
1206
R23
1W00
0R
2512
R31
W100
1M0
0805
R26
W100
1M0
0805
R27
W100
1M0
0805
R28
W250
0R
1206
R33
W250
0R
1206
R32
PID101
PID102
COD1
PID201PID202
COD2
PID301
PID302
COD3
PILD101
PILD102
COLD1
PILD201
PILD202
COLD2
PIQ101
PIQ102
PIQ103
COQ1
PIQ201
PIQ202
PIQ203
COQ2
PIQ301
PIQ302
PIQ303
COQ3
PIQ401
PIQ402
PIQ403
COQ4
PIQ501
PIQ502
PIQ503
COQ5
PIQ601
PIQ602
PIQ603
COQ6
PIR101 PIR102
COR1
PIR201
PIR202
COR2
PIR301
PIR302
COR3
PIR401
PIR402
COR4
PIR501
PIR502
COR5
PIR601
PIR602
COR6
PIR701
PIR702
COR7
PIR801
PIR802
COR8
PIR901
PIR902
COR9
PIR1001
PIR1002
COR10
PIR1101
PIR1102
COR11
PIR1201
PIR1202
COR12
PIR1301
PIR1302
COR13
PIR1401
PIR1402
COR14
PIR1501
PIR1502
COR15
PIR1601
PIR1602
COR16
PIR1701
PIR1702
COR17
PIR1801
PIR1802
COR18
PIR1901
COR19
PIR2001
COR20
PIR2101
PIR2102
COR21
PIR2201
PIR2202
COR22
PIR2301
PIR2302
COR23
PIR2401 PIR2402
COR24
PIR2501
PIR2502
COR25
PIR2601
PIR2602
COR26
PIR2701
PIR2702
COR27
PIR2801
PIR2802
COR28
PIR2901
PIR2902
COR29
PIR3001
PIR3002
COR30
PIR3101
COR31
PIR3201
COR32
PIR3301
COR33
PIW101 COW1:1
PIW102 COW1:2
PIW103 COW1:3
PIW104 COW1:4
PIW105
COW1:5
POSILENT
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
K K
J J
I I
H H
G G
F F
E E
D D
C C
B B
A A
Design Information And History
Section:
Product(s):
History.SchDoc
M1811 1 *
Sheet OfPCB#: Rev#:
Modified:
V02
File:2019-03-20
SA315S
EML Rev#:
XX
Tmp Rev: V031
CHANGE HISTORY POTENTIOMETERS AND KNOBS
PINOUT DIAGRAMS
DESIGN HISTORY AND INFORMATION
THIS SHEET CONTAINS A CHANGE HISTORY LOG, A LIST OF THE POTS & KNOBS AND A LEADS & PINS REFERENCE SECTION.
V01P2 RELEASE FOR PRODUCTION
RELEASE FOR PRODUCTION
.
.
.
.
.
.
.
.
.
.
.
V02
.
.
.
.
.
.
.
.
.
.
.
07-NOV-2018
13
10
7
4
1
9
11
12
8
#
2
3
5
6
VER#DATE DESCRIPTION OF CHANGE
20-FEB-2019
.
.
.
.
.
.
.
.
.
.
.
PC#
.
.
.
.
.
.
.
.
.
.
.
.. .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
13
10
7
4
1
9
11
12
8
#
2
3
5
6
VER#DATE DESCRIPTION OF CHANGE
.
.
.
.
.
.
.
.
.
.
.
.
PC#
.
.
.
.
.
.
.
.
.
.
.
.
.. .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
13
10
7
4
1
9
11
12
8
#
2
3
5
6
VER#DATE DESCRIPTION OF CHANGE
.
.
.
.
.
.
.
.
.
.
.
.
PC#
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
REF POT#FUNCTION KNOB#
POTENTIOMETERS AND KNOBS
.
.
.
.
.
.
.
.
.
.
.
.. .
.
.
.
.
.
.
.
.
.
Q1
R5
R15
DISCHARGE P.C.B.
Q2
Q6
W1
R16
R4
R3
R14
LD2
R7
R17
R26
R28
R31
R24
R2
D1
R6
R20
R21
R11
R18
R10
R22
R9
R33
R1
Q3
R19
D3
R12
Q4
R29
R27
LD1
R25
LABEL
R8
DISCHARGE
FROM CAPACITOR BOARD
INDICATING LED
INDICATING LED
D2
Q5
POWER ON
R23
R32
R30
R13
S/N
1 OZ.PCB
SINGLE LAYER
1.5mm ALUMINUM
475K
100R
475K 475K
100R
MMBTA42
221R
7994
475K 475K
0R
475K
680R
680R
0R
680R
100R
0R
18V
10K
2K74
330R0
100R
1M0
RED
0R
100R
MMBTA92
RED
100R
IRFR825
IRFR825
MMBTA42
475K
1M0
475K
475K
1K800
1M0
475K
4148
8V2
0R
1M0
IRFR825
PAD102
PAD101
PAD103
COD1
PAD201PAD202
COD2
PAD302 PAD301
COD3
PAHW200 PAHW300
PAHW400
COHW4
PAHW900
COHW9
PALD102
PALD101
COLD1
PALD201
PALD202
COLD2
PAQ101
PAQ103
PAQ102
COQ1
PAQ201
PAQ203
PAQ202
COQ2
PAQ303
PAQ301
PAQ302
COQ3
PAQ403
PAQ401
PAQ402
COQ4
PAQ503
PAQ501 PAQ502
COQ5
PAQ601
PAQ603
PAQ602
COQ6
PAR101
PAR102
COR1
PAR201
PAR202
COR2
PAR302PAR301
COR3
PAR402 PAR401
COR4
PAR501
PAR502
COR5
PAR601
PAR602
COR6
PAR701PAR702
COR7
PAR801PAR802
COR8
PAR901PAR902
COR9
PAR1001PAR1002
COR10
PAR1101
PAR1102
COR11
PAR1201
PAR1202
COR12
PAR1301
PAR1302
COR13
PAR1401
PAR1402
COR14
PAR1501PAR1502
COR15
PAR1601
PAR1602
COR16
PAR1702
PAR1701
COR17
PAR1801
PAR1802
COR18
PAR1901
COR19
PAR2001
COR20
PAR2101PAR2102
COR21
PAR2201PAR2202
COR22
PAR2301PAR2302
COR23
PAR2401
PAR2402
COR24
PAR2501
PAR2502
COR25
PAR2601
PAR2602
COR26
PAR2701
PAR2702
COR27
PAR2801
PAR2802
COR28
PAR2901PAR2902
COR29
PAR3001
PAR3002
COR30
PAR3101
COR31
PAR3201
COR32
PAR3301
COR33
COSNL2
PATH100
COTH1
PATH200
COTH2
COTITLE1
PAW105
PAW102
PAW101
PAW104
PAW103
COW1
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
K K
J J
I I
H H
G G
F F
E E
D D
C C
B B
A A
Assembly Documentation
Section:
Product(s):
Assembly.SchDoc
M1811 2 4
Sheet OfPCB#: Rev#:
Modified:
V02
File:2019-03-20
SA315S
EML Rev#:
XX
Tmp Rev: V031
PCB ASSEMBLY DOCUMENTATION
1. INSPECT SOLDER JOINTS AFTER REFLOW
2. USE PIZZA CUTTER TO SEPARATE BOARDS FROM PANEL.
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
K K
J J
I I
H H
G G
F F
E E
D D
C C
B B
A A
Design Information And History
Section:
Product(s):
History.SchDoc
M1811 1 *
Sheet OfPCB#: Rev#:
Modified:
V02
File:2019-03-20
SA315S
EML Rev#:
XX
Tmp Rev: V031
CHANGE HISTORY POTENTIOMETERS AND KNOBS
PINOUT DIAGRAMS
DESIGN HISTORY AND INFORMATION
THIS SHEET CONTAINS A CHANGE HISTORY LOG, A LIST OF THE POTS & KNOBS AND A LEADS & PINS REFERENCE SECTION.
V01P2 RELEASE FOR PRODUCTION
RELEASE FOR PRODUCTION
.
.
.
.
.
.
.
.
.
.
.
V02
.
.
.
.
.
.
.
.
.
.
.
07-NOV-2018
13
10
7
4
1
9
11
12
8
#
2
3
5
6
VER#DATE DESCRIPTION OF CHANGE
20-FEB-2019
.
.
.
.
.
.
.
.
.
.
.
PC#
.
.
.
.
.
.
.
.
.
.
.
.. .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
13
10
7
4
1
9
11
12
8
#
2
3
5
6
VER#DATE DESCRIPTION OF CHANGE
.
.
.
.
.
.
.
.
.
.
.
.
PC#
.
.
.
.
.
.
.
.
.
.
.
.
.. .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
13
10
7
4
1
9
11
12
8
#
2
3
5
6
VER#DATE DESCRIPTION OF CHANGE
.
.
.
.
.
.
.
.
.
.
.
.
PC#
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
REF POT#FUNCTION KNOB#
POTENTIOMETERS AND KNOBS
.
.
.
.
.
.
.
.
.
.
.
.. .
.
.
.
.
.
.
.
.
.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

YORKVILLE SA221S Manuel utilisateur

Catégorie
Équipement musical supplémentaire
Taper
Manuel utilisateur