Load select 6 Select load 1
Protect mode 7, 13, 14
Select LVD mode, and press “+“ or “-“ to
change its value to 11.4 V, then press “OK” to
confirm.
Reconnect
voltage 13, 14, 15 Press “+“ or “-“, adjust its value to 12.8 V, then
press “OK“ to confirm.
Night detect
Dimming value 8, 13, 14 Press “+“ or “-“, adjust its value to 5.5 V, then
press “OK“ to confirm.
Evening time
Morning time 10, 11, 14
When icon 10 “Evening“ is on, press “+“ or “-“.
Adjust its value to 4 h, then press “OK“ to
confirm.
Press the key again. When icon 11 “Morning“
is on, press “+“ or “-“, adjust its value to 3 h,
then press “OK“ to confirm.
Time mode 16 Set up timer mode is based on dusk & dawn.
Send 1, 2, 3
Transmit all settings to the controller. When
transmitting, icon 3 “Transmit“ flashes. If the
transmission was successful, icon 2 “OK“ flashes
5 times. If an error occurred, icon 1 “ERROR“ is
displayed
CIS 05/10/20 (Single Load, Dimming)
Dual timer (load on for 4 hours after dusk, 3 hours before dawn), LVD: 11.4 V,
dimming (evening h 2, morning h 1, dimming LVD: 11.9 V), sealed battery,
dimming value: 60%, night detection: 5.5 V, reconnect voltage: 12.6 V.
NOTE: Dimming will be activated if battery voltage falls below 11.9 V and
returns to normal when battery voltage reaches 12.6 V.
Load control function:
Night and day detection voltage (solar open circuit voltage):
Key order Display
icon Setting
/ Power on (auto power-off)
Controller type 4 Select single load controller
Battery type 5 Select sealed battery, press “OK“ key
Load select 6 Select load 1
Protect mode 7, 13, 14
Select LVD mode, and press “+“ or “-“ to
change its value to 11.4 V, then press “OK“ to
confirm.
Reconnect
voltage
13, 14,
15
Press “+“ or “-“, adjust its value to 12.6 V, then
press “OK“ to confirm.
Night detect
Dimming value 8, 13, 14 Press “+“ or “-“ to adjust its value to 5.5 V, then
press “OK“ to confirm.
Evening time
Morning time
10, 11,
14
When icon 10 “Evening“ is on, press “+“ or “-“,
adjust its value to 4 h, then press “OK“ to
confirm.
Press the key again. When icon 11 “Morning“ is
on, press “+“ or “-“, adjust its value to 3 h, then
press “OK“ to confirm.
Time mode 16 Set up timer mode is based on dusk & dawn.
Load select 12 Select dimming
Protect mode 7, 13, 14 Select LVD mode, and press “+“ or “-“, change
its value to 11.9 V, then press “OK” to confirm.
Night detect
Dimming value
8, 12, 13,
14
Press the key twice, icon 12 “Dimming“ is
displayed. Press “+“ or “-“ to adjust its value to
60%, then press “OK“ to confirm.
Evening time
Morning time
10, 11,
14
When icon 10 “Evening“ is on, press “+“ or “-“
to adjust its value to 2 h, then press “OK“ to
confirm.
Press the key again. When icon 11 “Morning“ is
on, press “+“ or “-“ to adjust its value to 1h,
then press “OK“ to confirm.
Time mode 16 Set up timer mode is based on dusk & dawn.
Send 1, 2, 3
Transmit all settings to the controller. When
transmitting, icon 3 “Transmit“ flashes. If the
transmission was successful, icon 2 “OK“ flashes 5
times. If an error occurred, icon 1 “ERROR“ is
displayed
Saving function
The CIS-CU-LCD can save all settings into a file. After setting up, press
once for saving function. Icon 11 will be displayed. Save the file as “1“, “2“
or “3“ using “+“ or “-“ and “OK“. Press again to exit and return to set
function.
Download local file function
The CIS-CU-LCD can download local file for sending directly or setting
up again. Press once the key “Local“. The CIS-CU-LCD switches to local
function. Choose the file name using “+“ or “-“ then press “OK“ to confirm.
You can check each setting using the corresponding key, but you
cannot modify them. You can send these settings to the controller. For
this, press “Local“ again. It is now in “SET“ function. You can modify the
settings based on the setting from the local file and send them to the
controller.
Read function
The CIS-CU-LCD can read the setting from the controller.
Press once the key “Read“, the CIS-CU-LCD switches to reading function.
When transmitting, icon 17 “READ“ is on. If the transmission was
successful, icon 2 “OK“ flashes 5 times. You can check each setting using
the corresponding key. If an error occurred, icon 1 “ERROR“ is displayed.
Make sure to program only one controller at a time.
Factory setting
Key Display icon Factory setting
Controller type 4 Single load controller
Battery type 5 GEL battery
Load select 6, 12 Load 1 or dimming for single
load controller
Time mode 16 Based on dusk & dawn
Protect mode 7, 13, 14 SOC 4
Reconnect voltage 13, 14, 15 12.8/25.6 V
Night detect
Dimming value 8, 12, 13, 14 Night detection: 8/16 V
Dimming value: 50%
Evening time
Morning time 10, 11, 14 Evening hours: 15 h
Morning hours: D2D
The CIS-CU-LCD saves factory setting into a file 4. You can download local file 4
for sending directly or setting up again.
Technical Data
Power consumption Max. 100 mA (when in use)
Run-time Up to 20,000 transmission with 2,000
mAh batteries
Ambient temperature -20 to +50 °C
Dimensions 180 mm x 54 mm x 28 mm
Weight 136 g (without batteries)
Type of protection IP22
Liability Exclusion
The manufacturer shall not be liable for damages, especially on the
battery, caused by use other than as intended or as mentioned in this
manual or if the recommendations of the battery manufacturer are
neglected. The manufacturer shall not be liable if there has been service
or repair carried out by any unauthorized person, unusual use, wrong
installation, or bad system design.
Subject to change without notice.
Version: 20150727
Made in one of the following countries:
Germany - China - Bolivia - India
Phocos AG - Germany
www.phocos.com
9
ISO9001
RoHS