Transmitters and receivers are available in a 36 MHz UHF
frequency range with a total of 1,440 transmission/receiving
frequencies.
Transmitters and receivers have 20 frequency banks respec-
tively. Each of the channels in the frequency banks has been
factory-preset to a frequency. The frequency presets within one
frequency bank are intermodulation-free. These frequencies
cannot be changed.
The frequency bank “U” allows the user to store individual
frequencies which are freely selectable in 25-kHz steps. It might
be that these frequencies are not intermodulation-free.
The following table lists the frequency presets in the frequency
banks “1” to “20”.
The following factory-preset default settings can be recalled
any time via the Reset menu item:
Auto Lock inactive
Sensitivity SK –30 dB
SKM –18 dB
Mute Mode AF On/Off (SK)
Squelch low
AF Out EM +18 dB
Equalizer flat
Guitar Tuner inactive
Name name of the series
Pilot Tone will not be reset
User bank “U”will not be reset
Informations complémentaires concernant
les systèmes evolution wireless ew G3
Les émetteurs et les récepteurs sont disponibles dans une plage
de fréquences UHF de 36 MHz de largeur, ce qui autorise un
choix parmi 1440 fréquences d’émission et de réception.
Les émetteurs et les récepteurs possèdent 20 banques de fré-
quences, dans lesquelles chaque canal est préréglé en usine sur
une fréquence. Les fréquences préréglées au sein d’une banque
de fréquence sont compatibles entre elles, c.à.d. exemptes
d’intermodulation. Elles ne peuvent pas être modifiées.
La banque de fréquences « U »
permet de mémoriser des fréquen-
ces au choix,
qui peuvent être réglées par pas de 25 kHz. Il se
peut que ces fréquences ne soient pas exemptes d’intermodu-
lation.
Le tableau suivant dresse la liste des fréquences préréglées
dans les banques de fréquences « 1 » à « 20 ».
Les paramètres par défaut suivants, préréglés en usine, peuvent
être restaurés à tout moment via l’option Reset :
Auto Lock inactif
Sensitivity SK –30 dB
SKM –18 dB
Mute Mode AF On/Off (SK)
Squelch low
AF Out EM +18 dB
Equalizer flat
Guitar Tuner inactif
Name nom de la série
Pilot Tone n’est pas réinitialisé
Banque « U » n’est pas réinitialisée
Sennheiser electronic GmbH & Co. KG Printed in Germany
30900 Wedemark, Germany Publ. 01/09
www.sennheiser.com 532016/A01
626–662 MHz
US_BerB_626-662MHz_532016_1008_Sp4.fm Seite 1 Freitag, 6. Februar 2009 5:24 17
US TV-channel
Ch. 40 (626–632 MHz) Ch. 43 (644–650 MHz)
Ch. 41 (632–638 MHz) Ch. 44 (650–656 MHz)
Ch. 42 (638–644 MHz) Ch. 45 (656–662 MHz)
Channel Bank 1 Bank 2 Bank 3 Bank 4 Bank 5 Bank 6 Bank 7 Bank 8 Bank 9 Bank 10
1
626,500 632,900 638,200 644,750 650,150 656,850 626,950 633,700 639,250 646,500
2
627,600 633,900 639,400 645,250 651,150 657,750 628,300 635,100 640,650 647,450
3
628,250 634,550 640,200 646,650 652,800 658,500 631,550 636,850 643,150 649,900
4
629,200 635,700 640,850 647,850 653,400 659,700 632,700 639,350 646,650 650,650
5
630,450 636,500 642,550 648,850 654,900 660,750 635,500 641,350 648,300 652,000
6
631,250 637,000 643,000 649,600 655,300 661,200 636,350 642,900 649,000 655,550
Note US TV-Ch.
40
US TV-Ch.
41
US TV-Ch.
42
US TV-Ch.
43
US TV-Ch.
44
US TV-Ch.
45
US TV-Ch.
40 & 41
US TV-Ch.
41 & 42
US TV-Ch.
42 & 43
US TV-Ch.
43 & 44
Remarque Etats-Unis
canal TV 40
Etats-Unis
canal TV 41
Etats-Unis
canal TV 42
Etats-Unis
canal TV 43
Etats-Unis
canal TV 44
Etats-Unis
canal TV 45
Etats-Unis
canaux TV
40 & 41
Etats-Unis
canaux TV
41 & 42
Etats-Unis
canaux TV
42 & 43
Etats-Unis
canaux TV
43 & 44
Nota EE.UU. Canal
TV 40
EE.UU. Canal
TV 41
EE.UU. Canal
TV 42
EE.UU. Canal
TV 43
EE.UU. Canal
TV 44
EE.UU. Canal
TV 45
EE.UU. Canales
TV 40 & 41
EE.UU. Canales
TV 41 & 42
EE.UU. Canales
TV 42 & 43
EE.UU. Canales
TV 43 & 44
Observa-
ção
E.U.A. Canal
TV 40
E.U.A. Canal
TV 41
E.U.A. Canal
TV 42
E.U.A. Canal
TV 43
E.U.A. Canal
TV 44
E.U.A. Canal
TV 45
E.U.A. Canales
TV 40 & 41
E.U.A. Canales
TV 41 & 42
E.U.A. Canales
TV 42 & 43
E.U.A. Canales
TV 43 & 44
626–662 MHz
Frequency Range / Bande de fréquence / Rango de frecuencia / Gama de frequências B2
US_BerB_626-662MHz_532016_1008_Sp4.fm Seite 2 Freitag, 6. Februar 2009 5:24 17
Channel Bank 11 Bank 12 Bank 13 Bank 14 Bank 15 Bank 16 Bank 17 Bank 18 Bank 19 Bank 20
1
651,850 626,350 633,600 639,600 644,200 627,100 633,700 642,700 630,000 633,500
2
653,150 631,050 636,800 642,050 645,900 628,250 639,850 646,600 635,050 643,200
3
655,000 633,150 640,500 645,500 650,450 634,100 642,000 652,550 642,450 645,100
4
659,100 635,900 642,950 646,600 654,400 636,400 645,700 654,900 644,900 650,700
5
660,100 639,350 644,900 650,250 657,000 642,100 653,800 660,300 650,200 652,250
6
661,750 643,600 649,600 656,350 661,900 648,950 654,900 661,750 654,000 660,250
Note U
S TV-
Ch.
44 & 45
U
S TV-
Ch.
40 & 42
U
S TV-
Ch.
41 & 43
U
S TV-
Ch.
42 & 44
U
S TV-
Ch.
43 & 45
U
S TV-
Ch.
40 & 43
U
S TV-
Ch.
41 & 44
U
S TV-
Ch.
42 & 45
U
S TV-
Ch.
40 & 44
U
S TV-
Ch.
41 & 45
Remarque Etats-Unis
canaux TV
44 & 45
Etats-Unis
canaux TV
40 & 42
Etats-Unis
canaux TV
41 & 43
Etats-Unis
canaux TV
42 & 44
Etats-Unis
canaux TV
43 & 45
Etats-Unis
canaux TV
40 & 43
Etats-Unis
canaux TV
41 & 44
Etats-Unis
canaux TV
42 & 45
Etats-Unis
canaux TV
40 & 44
Etats-Unis
canaux TV
41 & 45
Nota EE.UU. Canales
TV 44 & 45
EE.UU. Canales
TV 40 & 42
EE.UU. Canales
TV 41 & 43
EE.UU. Canales
TV 42 & 44
EE.UU. Canales
TV 43 & 45
EE.UU. Canales
TV 40 & 43
EE.UU. Canales
TV 41 & 44
EE.UU. Canales
TV 42 & 45
EE.UU. Canales
TV 40 & 44
EE.UU. Canales
TV 41 & 45
Observação E.U.A. Canales
TV 44 & 45
E.U.A. Canales
TV 40 & 42
E.U.A. Canales
TV 41 & 43
E.U.A. Canales
TV 42 & 44
E.U.A. Canales
TV 43 & 45
E.U.A. Canales
TV 40 & 43
E.U.A. Canales
TV 41 & 44
E.U.A. Canales
TV 42 & 45
E.U.A. Canales
TV 40 & 44
E.U.A. Canales
TV 41 & 45
The frequency bank “U” allows
the user to store frequencies
that are freely selectable
La banque de fréquences « U »
permet de mémoriser des fréquences
sélectionnables au choix.
En el banco de canales «U», las
frecuencias se pueden elegir
libremente
No banco de canais «U», as
frequências podem ser livremente
seleccionadas
US_BerB_626-662MHz_532016_1008_Sp4.fm Seite 3 Freitag, 6. Februar 2009 5:24 17
Información adicional para
sistemas Sennheiser de la serie
evolution wireless G3
Para la transmisión se dispone de un rango de frecuencia de
36 MHz de amplitud con 1440 frecuencias de transmisión/
recepción posibles en la banda UHF.
Los transmisores y receptores cuentan con 20 bancos de canales
cada uno para los que se ha preajustado una frecuencia en
fábrica. Dentro de un banco de canales, los preajustes de
frecuencia se encuentran libres de intermodulación entre ellos.
Éstos no se pueden cambiar.
En el banco de canales «U» puede ajustar libremente y guardar
frecuencias a pasos de 25 kHz. Estas frecuencias pueden no
estar libres de intermodulación.
Los preajustes de frecuencia en los bancos de canales «1» a
«20» se representan en la siguiente tabla.
Con la opción de menú «Reset», se pueden llamar de nuevo los
siguientes ajustes de fábrica en todo momento:
Auto Lock inactivo
Sensitivity SK –30 dB
SKM –18 dB
Mute Mode AF On/Off (SK)
Squelch low
AF Out EM +18 dB
Equalizer flat
Guitar Tuner inactivo
Name nombre de la serie
Pilot Tone no se resetea con Reset
User Bank no se resetea con Reset
Informações adicionais relativamente
a sistemas Sennheiser da série
evolution wireless G3
Para a transmissão em banda UHF, encontra-se à disposição
uma gama de frequências de 36 MHz de largura com 1440
possíveis frequências de transmissão/recepção.
Os transmissores e receptores dispõem de 20 bancos de canais
cada um, nos quais está predefinida, de fábrica, um frequência.
Dentro de um mesmo banco de canais, as predefinições de
frequência estão livres de intermodulação. Não podem ser alte-
radas.
No banco de canais «U», as frequências podem ser livremente
definidas e guardadas em passos de 25 kHz. Sob determinadas
circunstâncias, estas podem não estar livres de intermodulação.
As predefinições de frequência nos bancos de canais «1» a
«20» são enunciadas na tabela seguinte.
No item de menu «Reset» podem repor-se, em qualquer altura,
as regulações de fábrica seguintes:
Auto Lock inactivo
Sensitivity SK –30 dB
SKM –18 dB
Mute Mode AF On/Off (SK)
Squelch low
AF Out EM +18 dB
Equalizer flat
Guitar Tuner inactivo
Name nome da série
Pilot Tone não é possível repor com o Reset
Banco do utilizador não é possível repor com o Reset
US_BerB_626-662MHz_532016_1008_Sp4.fm Seite 4 Freitag, 6. Februar 2009 5:24 17
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Sennheiser EW 114 G3 Le manuel du propriétaire

Taper
Le manuel du propriétaire