Extron TLP Pro 1025M Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

1
TLP Pro 525M, 725M, and 1025M Series • Setup Guide
Overview
The Extron TLP Pro 525M, TLP Pro 725M, and TLP Pro 1025M are three series of wall mounted capacitive touchscreen touchpanels
with a TFT active matrix color LCD screens.
The TLP Pro 525M series touchpanels have a 5-inch screen with a 800x480 resolution and 24-bit color depth.
The TLP Pro 725M series touchpanels have a 7-inch screen with a 1024x600 resolution and 24-bit color depth.
The TLP Pro 1025M series touchpanels have a 10.1-inch screen with a 1280x800 resolution and 24-bit color depth.
They are ideal for any AV application requiring compact touchpanels with exible mounting options and fully customizable interfaces.
This guide provides instructions for experienced installers to mount and install these touchpanels.
Setup Checklist
Get Ready
Download and install the latest version of the following software:
GUI Designer — For designing layouts for Extron TouchLink
®
Pro touchpanels and third party touch interfaces.
Global Configurator
®
Professional and Global Configurator Plus — For setting up and conguring the control processor
and touchpanel.
Toolbelt — Provides device discovery, device information, rmware updates, and conguration of network settings, system
utilities, and user management for TouchLink Pro devices.
Global Scripter
®
— Provides an integrated development environment for Extron control systems programming.
NOTE: All four software programs are available from www.extron.com.
Obtain the following network information from your network administrator:
DHCP status — (on or off). If DHCP is off, you must also obtain:
IP address Subnet mask Gateway
User name — This can be either admin or user.
PasswordThe factory congured passwords for all accounts on this device have been set to the device serial
number. Passwords are case sensitive.
NOTE: If the device is reset to default settings, the password will be the default password conguration. The
default password is extron (for either admin or user).
Make a note of the touchpanel MAC address.
Mount and Cable All Devices
ATTENTION:
Do not power on the touchpanels or control processors until you have read the Attention in the “Rear Panel Features”
section of the TLP Pro 525, 725, and 1025 Series User Guide or the IPCP Pro User Guide or IPL Pro User Guide.
Ne branchez pas les écrans tactiles ou les contrôleurs avant d’avoir lu la mise en garde dans la section «Rear Panel
Features » du TLP Pro 525, 725, and 1025 Series User Guide ou du IPCP Pro User Guide or IPLProUserGuide.
Mount the units. There are several mounting options for TouchLink Pro touchpanels (see Mounting on the next page).
Connect the touchpanel to a Power over Ethernet injector (see figure 5 on page 5).
Connect the power injector to the LAN and power it on (see figure 5).
Set up the Touchpanels for Network Communication
Connect the PC that you are using for setup, the control processor, and the touchpanel to the same Ethernet subnetwork.
Use the Setup Menu (see page 6) or Toolbelt to set the DHCP status and, if necessary, the IP address, subnet mask, gateway,
and related settings for the touchpanel.
Configure the Touchpanels
The GUI Designer Help File, the Global Configurator Help File, and the Toolbelt Help File provide step-by-step instructions and
detailed information. The Global Configurator Help File includes an introduction to the software and sections on how to start a project
and conguration.
Global Scripter provides an Extron-exclusive Python library (ControlScript
®
) and Global Scripter modules to get you started.
2
TLP Pro 525M, 725M, and 1025M Series • Setup Guide (Continued)
Mounting
All these touchpanels can be wall-mounted, either using a UL-listed junction box, an external wall box, or directly into drywall or
furniture. Suitable mounting accessories can be found at www.extron.com.
ATTENTION:
Do not install touchpanels in a re resistant rated wall or partition assembly.
Ne pas installer les écrans tactiles sur un mur protégé par un dispositif coupe-feu ou dans une cloison.
All structural steps and electrical installation must be performed by qualied personnel in accordance with local and
national building codes and electrical codes.
Toute étape structurelle et installation électrique, doit être effectuée par un personnel qualié, conformément aux
codes du bâtiment, aux codes incendie et sécurité, et aux codes électriques, locaux et nationaux.
Figure 1 shows the TLP Pro 725M. Installation for the TLP Pro 525M or TLP Pro 1025M is very similar.
With a Wall Box or Junction Box
Some local building codes require the touchpanel to be mounted in a junction box. Junction boxes or wall boxes must be purchased
separately.
NOTES:
The TLP Pro 525M touchpanels mount to a 1-gang junction box. The US 1-gang junction box should be installed so that the
long side is horizontal. EU or MK 1-gang junction boxes should be installed in the standard orientation.
The TLP Pro 725M and 1025M touchpanels mount to a 2-gang junction box.
Extron provides four 3/4" #6-32 Philips pan head screws for mounting to US junction boxes
Extron provides two 16 mm M 3.5 Philips pan head screws for mounting to MK junction boxes
EU junction boxes are usually provided with their own screws.
With a wall box
1. Install a junction box or wall box (see gure 1,
1
),
following the instructions provided by the manufacturer.
2. Fasten the mounting plate to the wallbox (
2
) with
the provided screws. Use the mounting holes that
are appropriate to the junction box you are using (see
figure 2, on the following page).
3. Run and connect cables to the back of the touchpanel
(see Rear Panel Features on the following page).
4. The TLP Pro 525M mounting plate has two hooks
(one in each top corner). The TLP Pro 725 M and
TLP Pro 1025M mounting plate has four hooks (
3
), one
in each corner (see figure 2).
Position the touch panel so that the mounting slots (see
figure 4,
D
) in the rear of the touchpanel align with
these hooks.
5. Move the touchpanel inward and downward so that
touchpanel sits securely on the hooks and the tongue at
the bottom of the mounting plate (
4
) sits in the groove
in the bottom of the touchpanel (see inset, gure 1,
5
).
6. Fasten the touchpanel to the mounting plate with the
lock screw (
6
).
steps 3 through 6
TOP
e
Back View
1
2
3
4
5
6
4
Figure 1. Mounting the TLP Pro 725M with a Junction Box
gure 1
3
Product Category
NORTH
AMERICAN
NORTH
AMERI
CAN
MK
MK
EU/MK EU/MK
WALL
WALL
WALL
WALL
NORTH
AMERICAN
NORTH
AMERICAN
NORTH
AMERICAN
NORTH
AMERICAN
EU
MK
EU
EU
EU
MK
Figure 2. TLP Pro 525M Mounting Plate (left) and TLP Pro 725M and 1025M Mounting Plate (right)
NOTE: The TLP Pro 725M and TLP Pro 1025M series touchpanels use the same mounting plate.
Without a wall box
If the wall box is not required by local building codes, you can mount the touchpanel directly into drywall.
1. Use the mounting plate as a template to mark the wall or download the cut-out template for your product from www.extron.com.
Place the template or mounting plate against the wall or furniture in a suitable location and ensure that it is level.
2. Mark the position of the hole and cut the wall.
For the TLP Pro 525M, this hole is 2.4 inches (61 mm) wide x 2.1 inches (53 mm) high.
For the TLP Pro 725M or 1025M, this hole is 3.5 inches (89 mm) wide x 2.0 inches (51 mm) high.
3. Mark the slots labeled WALL (TLP Pro 525M) or MK (TLP Pro 725M or TLP Pro 1025M) (gure 2) and drill the two pilot holes. Extron
recommends using two Molly bolts or SnapToggle bolts.
4. Secure the mounting plate to the wall (see figure 1,
2
, on the previous page).
5. Complete the installation as described in steps 3 through 6 on the previous page.
gure 2
Front Panel Features
Figure 3 shows the front panel of the TLP Pro 725M. The front
panels of all the touchpanels have the same features and are
almost identical apart from the size.
A
Motion sensor — Detects motion between three to ve feet
from the touchpanel, and at least 15° from the center axis.
If the sleep timer has been set (see Setup Menu on the
next page), and no motion has been detected for a user-
dened period of time, the touchpanel enters sleep mode.
If Wake on Motion has been set (see Setup Menu), and
motion is detected by the sensor while the screen is in
sleep mode, the screen display is restored and active.
B
Communication LED — Shows the conguration and
connection status of the touchpanel:
Unlit during normal operation (the touchpanel is
congured and connected to an IP Link Pro control
processor).
Extron
A
A
AB
B
BC
C
CA
A
A
D
D
D
E
E
E E
E
E
Figure 3. TLP Pro 725M Front Panel
Blinks red if the touchpanel has been congured but is not connected to an IP Link Pro control processor.
Lit solidly red if the touchpanel has not been congured.
The indicator can be toggled between enabled and disabled, using the Setup Menu.
C
Light sensor — Monitors ambient light level and adjusts screen brightness.
D
Capacitive touchscreen
The TLP Pro 525M series has a 5-inch screen with a 800x480 resolution.
The TLP Pro 725M series has a 7-inch screen with a 1024x600 resolution.
The TLP Pro 1025M series has a 10.1-inch screen with a 1280x800 resolution
E
Status lights — Two LED light bars, one on either side of the screen, which can be programmed to provide system feedback.
Light red or green Blink or stay continuously lit
For information about programming these LEDs, see the Global Configurator Help File and Global Scripter Help File.
4
TLP Pro 525M, 725M, and 1025M Series • Setup Guide (Continued)
Rear Panel Features
D
D
D
C
C
CA
A
AB
B
B
E
E
E
J
J
JH
H
H
TLP Pro 525M
I
I
I
G
G
G
D
D
D
C
C
CA
A
AB
B
B
E
E
E
F
F
F
G
G
G
H
H
HI
I
I J
J
J
K
K
K
D
D
D
D
D
D
D
D
D
D
D
D
TLP Pro 725M
F
F
F
C
C
CA
A
AB
B
B
H
H
H
H
H
H
E
E
E
F
F
F
G
G
G
D
D
D
D
D
D
K
K
K
D
D
D
D
D
D
I
I
I J
J
JTLP Pro 1025M
Figure 4. TLP Pro 525M, 725M, and 1025M Rear Panels
gure 4
NOTE: The panels shown in gure 4 are for illustration
only and are not to the same scale.
For more information, follow these links to the next page.
A
Menu Button
B
Reset Button
C
Reset LED
D
Mounting Slots
E
Digital Input Monitoring Port
F
LAN/PoE Connector
G
USB Port
H
Speaker
I
Slot for Mounting Plate
J
Mounting Screw
K
Rear Panel Status Lights
5
Product Category
A
Menu Button (see figure 4 on the previous page)— Activates the setup menu (see Setup Menu on the next page).
B
Reset Button — Pressing the Reset button allows the unit to be reset in any of three different modes (for an overview, see Reset
Modes, on the next page).
C
Reset LED — Provides feedback about the reset status when the user presses the Reset button (see Reset Modes).
D
Mounting Slots — The TLP Pro 725M and TLP Pro 1025M have four, one in each corner. The TLP Pro 525M has two, one in each
top corner. The hooks on the corners of the mounting plate (see figure 1,
3
on page 2) t into these slots for wall mounting.
E
Digital Input Monitoring Port — This two-pole captive screw port (1 = signal and G = ground) monitors digital input with or
without a +5 VDC pull-up.
F
LAN/PoE Connector — Connect the touchpanel to a PoE power injector (not provided) using a twisted pair cable, terminated
with an RJ-45 connector. Connect the power injector to the LAN through a nework switch. An Extron IP Link Pro control
processor must also be connected to the same network as the TouchLink Pro touchpanel.
ATTENTION:
The TLP Pro 525M, TLP Pro 725M and TLP Pro 1025M are Power over Ethernet (PoE 802.3af, class 3) compliant.
Do not power on the touchpanels until you have read the Attention in the “Rear Panel Features” section of the
TLP Pro 525, 725, and 1025 Series User Guide.
Le TLP Pro 525M, le TLP Pro 725M et le TLP Pro 1025M supportent l’alimentation via Ethernet (PoE 802.3af,
classe 3). Veuillez lire la partie « Attention » dans la section « Rear Panel Features » du TLP Pro 525, 725, and
1025 Series User Guide, avant de mettre sous tension les écrans tactiles.
NOTE: These touchpanels are shipped without a power injector. The
power injector must be purchased separately.
Menu Button
Reset Button
Reset LED
Mounting Slots
Digital Input Monitoring Port
LAN/PoE Connector
Extron recommends the Extron XTP PI 100 power injector (see gure 5).
Your power injector may look different.
G
USB Port — Compatible with USB 2.0.
H
Speaker — Provides audible feedback for the user.
TLP Pro 525M — a single speaker
TLP Pro 725M — a single speaker
TLP Pro 1025M — two (dual mono) speakers
I
Slot for Mounting Plate — The tongue at the bottom of the mounting
plate (see figure 1,
4
) ts into this slot, for wall mounting.
USB Port
Speaker
Slot for Mounting Plate
100-240V
~
50-60Hz
0.4A MAX
XTP
PWR
XTP PWR
To network switchTo touchpanel
Figure 5. XTP PI 100 Power Injector
gure 5
J
Mounting Screw — Tightens against the tongue of the mounting plate to secure the touchpanel.
K
Rear Panel Status Lights
TLP Pro 525M — no lights
TLP Pro 725M — Six lights, three on each side of the panel
TLP Pro 1025M — Two lights, one on each side of the panel
These lights can be programmed to provide system feedback:
light red or green
Blink or stay continuously lit
The rear panel status lights can be toggled between enabled and disabled by using the Setup Menu (see the next page).
For information about programming these LEDs, see the Global Configurator Help File and Global Scripter Help File.
Mounting Screw
Rear Panel Status Lights
6
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
© 2018 - 2019 Extron Electronics — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
TLP Pro 525M, 725M, and 1025M Series • Setup Guide (Continued)
Reset Modes: a Brief Summary
These touchpanels provide the following reset modes (see the TLP Pro 525, 725, and 1025 Series User Guide for complete
information):
Use Factory Firmware — With the unit powered off, press and hold the Reset button (see figure 4,
B
on the previous page)
while reapplying power to the unit. Use this mode with Toolbelt software to replace rmware in the event of conicts arising
from uploading a rmware update.
Reset All IP Settings — Press and hold the Reset button for 6 seconds. After the Reset LED (
C
) ashes twice, release and
momentarily press the Reset button. Use this mode to reset all network settings without affecting user-loaded les.
Reset to Factory Defaults — Press and hold the Reset button for 9 seconds. After the Reset LED ashes three times,
release and momentarily press the Reset button. Use this mode to return the touchpanel to factory default settings.
NOTES:
The factory congured passwords for all accounts on this device have been set to the device serial number. Passwords
are case sensitive.
If the device is reset to default settings, the password will be the default password conguration. The default password is
extron (for either admin or user).
Reset Modes
Status
Display Audio Advanced Exit
Network
Info
Model: TLP Pro 725M
Part Number: 60-1563-02
Firmware
Version:
1.02.0001-b001
Network
IP Address:
DHCP:
Host Name:
Off
192.168.254.251
TLP-AB-CD-EF
Display
Resolution:
GUI Project:
Sleep Timer:
1024x600
N/A
5 Minutes
Audio
Master Volume:
Master Mute: Off
99
Advanced
Controller IP: N/A
Project Size: N/A
Bootloader
Version:1.03.0000
Figure 6. Setup Menu: Status Screen for TLP Pro 725M
Setup Menu
Figure 6 shows the Status screen for the TLP Pro 725M. The
screen for the TLP Pro 525M or TLP Pro 1025M are similar.
Press the Menu button (figure 4,
A
) to open the setup menu.
Select any of the ve available screens (Status, Network,
Display, Audio, and Advanced) by pressing the appropriate
button in the navigation bar at the top of the screen (for more
information, see the TLP Pro 525, 725, and 1025 Series User
Guide).
68-2831-53 Rev. B
12 19
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Extron TLP Pro 1025M Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues