American Standard Advanced Clean 100 SpaLet Guide d'installation

Taper
Guide d'installation

Ce manuel convient également à

-1 EN-
PCW-1331-US-ASB (19010)
Thank you for purchasing this product.
CAUTION
● Carefullyreadthis
installationmanualtoinstall
thisproductcorrectly.
● Besuretotestoperation
afterinstallationhasbeen
completed.
Installation Procedure
1 Mounting the SpaLet Bowl
↓
2 Attaching the Water Shutoff
Valve
↓
3 Mounting the Seat Unit
↓
4 Connecting the Water Supply
Hose <Seat Unit End>
↓
5 Connecting the Water Supply
Hose <Water Shutoff Valve End>
↓
6 Connecting to the Power Supply
↓
7 Positioning and Mounting the
Remote Control
↓
8 Test Operation
↓
9 Mounting the Side Cover
Installation Manual
Advanced Clean 100 SpaLet® Bidet Seat
Model:8017A60GRC
7302385-100 7302385-100EN
-2EN-
This manual consists of two parts; the rst part
contains safety precautions and descriptions of the
procedures when installing the SpaLet, and the
second part contains visual installation methods.
Please use this manual in reference to each part.
SAFETY PRECAUTIONS
For safe installation and use of the product,
please read the precautions thoroughly
before installing the product.
DANGER An imminently hazardous situation
which, if not avoided, will result in death
or serious injury
WARNING A potentially hazardous situation which,
if not avoided, could result in death or
serious injury.
CAUTION
A potentially hazardous situation which,
if not avoided, may result in minor or
moderate injury or damage to the
product or other property.
DANGER
Improper connection of the power plug or
socket can result in a risk of electric shock.
All electrical installation work must be carried
out by a qualied electrician.
There is a danger of short circuit and/or
electric shock.
WARNING
Follow the instructions described in this
manual, and install the product properly.
Failure to do so may cause electric shock, re,
injury, water leakage, and/or ooding.
Do not allow anyone except a certied
electrician to disassemble, repair, or modify
the product.
There is a danger of electric shock or re, and
the product could malfunction, causing injury.
Do not connect or disconnect the power plug
or socket or power cord with wet hands.
There is a danger of electric shock.
Hold the plug or socket when connecting
or disconnecting the power plug or socket.
If the plug or socket is connected or
disconnected by holding the cord, there is
a danger of re or electric shock due to the
plug or socket or cord becoming damaged.
Do not pour water or the cleanser inside or
onto the SpaLet seat unit, remote
control, or power plug or socket.
It may cause electric shock or re.
Do not use any power supply other than
AC120V. Also, do not use any other
method to connect the plug or socket to an
improperly congured receptacle,
exceeding the rated voltage for use.
Be sure to use a VVF cable (with solid
copper wires 20 AWG each) for the power
cord. If a power cord other than the one
specied above is used (such as
strand wires, strand wires attached
with terminals, etc.), it may result in
overheating due to bad connection and
cause corrosion, burnout, re of the prod-
uct and cord.
Connect the power completely. There is a
danger of re or electric shock due to the
cord becoming damaged.
Do not damage, bend, modify,
excessively twist, bind, sandwich, or
place heavy objects on the power cord.
There is a danger of re or electric shock
due to the cord becoming damaged.
Do not install this product in a wet or
damp location, such as inside a shower
room or steam room.
There is a danger of electric shock or re.
-3 EN-
Do not attach the product to any water source
other than potable water.
It may cause electric shock, re and skin
inammation due corrosion of electronic parts
inside the seat unit.
Do not disassemble or modify the product.
It may cause electric shock or re.
Do not use loose outlet.
It may cause electric shock or re.
CAUTION
Install a high-sensitivity, high-speed ground
fault circuit interrupter (with a rated current
value of 15 mA or below) on the primary side
of the power supply.
There is a danger of electric shock.
The SpaLet® bowl is made of ceramics, and
ceramics are fragile. Note the following when
handling the SpaLet bowl:
–– Prior to installation, make sure that the
SpaLet bowl is in a good condition and
not damaged.
–– After installation, check the SpaLet bowl
for any damages.
Failure to do so may cause injury, water
leakage and/or ooding.
Wash out foreign materials or rust inside the
pipes before connecting the product.
Failure to do so could damage the internal
parts of the product, which may cause water
leakage and/or ooding.
Note the following when using the strainer:
–– Close the water shutoff valve when
removing the strainer.
–– When installing the strainer, tighten it
fully so there is no gap.
–– Check that the O-ring is free from
foreign materials when attaching it.
If foreign materials are attached to the O-ring,
it may cause ooding due to water leakage.
Adjust the water shutoff valve and check for
water leakage after the installation.
It may cause water leakage and/or ooding.
If the water is expected to be frozen,
drain the water out from the product.
Failure to do so may cause re, water
leakage, and/or ooding due to damage
from freezing.
Drain the air from the pipes after any
building construction or renovation, or
when water supply is restored after an
interruption.
If the water supply contains air, it may
cause damage or malfunction to the
product or pipes. There is a danger of
injury or damage to the building or
furniture due to ooding.
-4 EN-
POWER SUPPLY
Installthecordandoutletaccordingtothe
specicationsbelow.
Thepowerdistributionworkshouldbedonebyan
electricalcontractor.
Use an AC120V power supply with a
consumption rating.
Iftheproductisusedwithotherelectricappliances,
setthecorrespondingnumberofoutlets.
The wiring should be appropriate for the rated
power consumption.
Set the outlet within the reach of the cord and
high enough from the floor so that water does
not reach it. The length of the power cord
is 1 m (39-3/8").
Donotconnectthepowerplugtotheoutletuntilthe
installationiscompleted.Thereisdangerofmalfunction
.
WATER SUPPLY
The SpaLet toilet uses solenoid valves which are
fast acting or quick closing valves. The use of
water hammer arrestors is strongly recommended
for this product. All piping behind the walls
should be properly secured and fastened.
Only use potable water as the water supply.
Usingadifferentwatersupply(industrialwater,
wellwater,etc.)maycausethedurabilityofthe
electricalandmechanicalcomponentsto
deteriorate,resultinginanaccidentormalfunction.
The water pressure must be more than
0.175MPa/25 PSI (hydrostatic pressure) and
0.10MPa/14.5 PSI (flow pressure) and 17L/min.
when flowing.
If the water pressure is higher than
0.75MPa/109 PSI, decompress the pressure
by using a decompression valve.
MINIMUM INSTALLATION CLEARANCE
For the required minimum installation clearance,
refertothegurebelow.
* 1Aspaceof70mm(2-3/4")ormoreoneachsideof
theproductisrecommended.Ifitislessthan70mm
(2-3/4"),itmayhindertheoperation.
* 2
Placethewatershutoffvalveto2"(50mm)from
thewall.
*1
70 (2-3/4) min.
*1
70 (2-3/4)
min.
375 (14-3/4) min.
400 (15-3/4) min.
*2
50 (2)
min. 1050 (41-5/16) min.
Remote Control
280
(11)
700 (27-9/16) min.
15 (9/16) min.
Unit: mm
(")
INSTALLATION POSITION OF THE REMOTE CONTROL
a
b b
1300 mm (51-3/16")
On the left side On the right side
Installtheremotecontrolontheleftwallwhenfacing
theSpaLetunit,sothatitisonthesamesideasthe
remotecontrolsignalreceiverasfaraspossible.If,
foranychance,theremotecontrolhastobeinstalled
ontherightside,checkifthereceiverwillreceive
thesignal,beforehand.Moreover,ifthewallissome
distanceawayfromtheSpaLetunit,forexampledueto
alayoutsuchasawashstandbeinginstalledbetween
thewallandtheunit,thesignalmaynotbereceived
bythereceiver.Ifthisisthecase,erectascreenwhich
canreflectsignalswithin1300mm(51-3/16")fromthe
centeroftheSpaLetbowl.Thisscreenshouldbeat
least1100mm(43-5/16")inheightandshouldcover
thedistancebetweenthesignalreceiverandtheremote
control’sinstalledposition.(Notethattheconditions
mayvaryalittledependingonthewallfinishandcolor.)
a Remote control signal receiver
b Remote control
DO NOT PLACE SEAT UNIT ON FLOOR!
Neverplacetheseatunitonthefloor,asthismayresult
in breakage of the seat unit's mounting bolts or
water supply inlet.
NOTES PRIOR TO INSTALLATION
Do not hold the hose
at the rear of the
SpaLet bowl.
* Ifthehoseis
removed,thenthis
maycauseleaks,
andtheSpaLetwill
notflushproperly.
c Hoses
c
Finished
Wall
Remote
Control
Power AC
120V
3-1/4" (82 mm)
2-9/16"
(65 mm)
7-1/16" (180 mm)
Length
39-3/8"
(1000 mm)
Length
16-1/8"
(410 mm)
14-3/4"
(375 mm)
5-15/16"
(150 mm) Drainage Pipe
9-1/16"
(230 mm) 4-3/4" (121 mm)
15-3/16"
(385 mm)
1-3/8"
(35 mm)
16-9/16"
(420 mm)
20-5/8"
(524 mm)
12"
(305 mm)
Meets the Americans with Disabilities Act Guidelines
and ANSI A117.1 Requirements for Accessible and
Usable Building Facilities-Check Local Codes.
-5EN-
FIRMLY FIX THE WATER SUPPLY PIPE
An impact applied to the hose due to high water pressure
may cause vibrations.
Fix the water supply pipe rmly so that it does not loosen.
There is a danger vibration or ooding.
TECHNICAL DATA
Rated voltage
AC120V 50/60Hz
Rated power consumption
850 W (environment 68°F, water 59°F)
Max rated power consumption
1300 W (environment 68°F, water 59°F)
Length of the power cord
39-3/8" (1000 mm)
Length of the water supply hose
16-1/8" (410 mm)
Waterproof grade
IPX4
Water pressure range
Minimum: 0.175MPa/25 PSI [hydrostatic pressure] and
0.10MPa/14.5 PSI (ow pressure) and 17L/min. when owing.
Maximum: 0.75MPa/109 PSI
Water connection cross section
R1/2
Operating temperature range
30°F - 104°F
Units
V = volt, Hz = hertz, W = watt, m = meter,
MPa =mega pascal, in = inch,
°C = degrees Celsius, °F = degrees Fahrenheit,
PSI = pounds square inch
L = Liter, min. = minute
Flushing water volume
S-trap: full 1.32 gallons, light 0.90 gallons
HOW TO CHECK WATER PRESSURE
•Wheninstallingaushtoilet,checkthattherequiredwaterpressures(hydrostaticpressureandowpressure)speciedfor
eachappliancearesecured.
•Ifthewaterpressureexceeds0.75MPa,useapressurereducingvalvebeforeinstallationforuse.
[Water Pressure Checks]
Hydrostaticpressureandowpressurechecksarerequiredforinstallingwatersupplyappliances.Ifnowatershutoffvalvesor
pressuremeasuringdevicesarepreparedbeforehand,connecttheappliancesasshownbelowtomeasurethehydrostaticpressure
andowpressure.Byusingapressuremeasuringdevice,itwillbeeasytochecktheinstallationavailabilityoftheappliance.
Theowpressuregreatlyvaries,dependingontheperipheralconditionsincludingpiping.Besuretomakewaterpressure
measurementwiththewatersupplypipewheretheapplianceisinstalled.
[Hydrostatic Pressure Measuring Method]
Makewaterpressure(hydrostaticpressure)measurementinastatewherevalve1isfullyopenedandvalve2isfullyclosed.
[Flow Pressure Measuring Method]
(1)First,checkthatvalve2isfullyclosedandvalve1isfullyopened.Next,graduallyopenvalve2.Thenthehydrostatic
pressurewillgraduallydecrease(theowpressureisthewaterpressureatthetimeofwatersupply).
(2)Adjustvalve2sothatthewaterpressurewillsettotheminimumrequiredwaterpressureoftheproduct.Thenclosevalve1.
(3)Emptythebucket.Thenfullyopenvalve1andmeasurethetimeuntilthewaterlevelreachesthescaleofthebucket.
Calculatetheowratefromthebucketcapacitydividedbytheperiodoftimeandcheckthattheowratenecessaryforthe
useoftheproductissecured.
•
Iftheinstalledapplianceisusedsimultaneouslywiththewatersupplyapplianceinthekitchen,washroom,etc.,theowpressure
andtheowratewilldecrease.Inthatcase,measuretheowpressureinasimultaneousoperatingstateoftheappliances.
[Dedicated Pressure Measuring Device]
Useapressuremeasuringdevicetomakehydrostaticpressureandowpressurechecks.Itwillbeeasytochecktheinstallation
availabilityoftheappliance.
Water
Supply
Valve 1 for discharging
and shutting off water
Bucket with
scale
Pressure
Gauge
-6EN-
Parts names
Checking Parts (check inside the package)
Numbersinindicatethestepsintheprocedure.
Seatunit
(product,SpaLetseat,SpaLetlid)
Watershutoff
valve
Ring
shapedcover
Wood
screws
Plastic
anchors
Remotecontrol
Batteries
(AAAx2)
Holder
* Theholderisattachedtotherearofthe
remotecontrol.Slideitofftoremoveit.
Hexagonalnut
Spring
washer
Washer
Tool
Watersupply
hose
410mm
(16-1/8")
Clip(gray)
(OntheSpaLetbody
connectionside)
Clip(white)
(left) (right)
Sidecover
Attached
panel
Upperbodysensor
Remote
Control
Seatunit
Sidecover
Flushbutton
Remotecontrol
receiver
SpaLetbodyindicator
Powerplug
(withgroundfault
protected)
Watershutoffvalve
Open/closeknob
Water
supplyhose
Points of caution
Nozzleshutter
Product No.
Nozzle
(forrearwashing)
SpaLet
seat
Lowerbody
sensor
Nozzle
(for front
washing)
SpaLet
bowl
SpaLetlid
Strainer Deodorizinglter
Left side
(when facing the
SpaLet body)
Inside the nozzle
shutter
2 3
94 5 7
3
-7EN-
1 Mounting the SpaLet Bowl
Installation Procedure
1. Remove the open/close knob
<Floor water supply>
Wall
Watershutoffvalve
Water
shutoff
valve
Open/closeknob
Approx.
10°
Metaltoolsetting
(Hex)
Watersupplyinlet
100mm
(3-15/16")280mm
(11")
Centerline
ofthe
SpaLet
bowl
Watersupplypipe
Sealingtape
<Wall water supply>
Approx.
10°
Floor
Open/closeknob
Metaltoolsetting
(Hex)
Watersupplyinlet
150mm
(5-15/16")
280mm
(11")
Centerline
ofthetoilet
bowl
Water
supply
pipe
Sealingtape
2. Afxthewatershutoffvalvetothe
water supply pipe.
Performthisstepafternishingthewalland
oor.
Attachthesealingmaterial(sealingtapes)to
thethreadedsection.
* Hookthetoolonthehooksetting(hex)on
thewatershutoffvalve,andfastenit.
[See Note 2-2]
Wallwatersupply···Mountthewatersupply
inletatapprox.10°downwardrelativetothe
horizontallevel.
Floorwatersupply···Mountthewater
supplyinletatapprox.10°tiltedtothewall.
3. Install the open/close knob
* Checkthatthewatershutoffvalveisclosed.
Click
Open/close
knob
Positioning
groove
2 Attaching the water shutoff valve [See Note 2-1]
[Note 2-1]
Do not push or step on the water shutoff valve.
* Thepipemaycomeloose,orthewatershutoff
valvemaybedamaged,resultinginwater
leakage.
* Thewalloroormayalsobedamaged.
● Afxthewatershutoffvalvewatersupplyinlet
in such a way that the water supply hose is not
crimped.
[Note 2-2]
Ensure to hook the tool on the metal tool
setting(hex).
* Thewatershutoffvalvemaybedamaged,
resultinginwaterleakage.
Metaltoolsetting
Resin
-8EN-
Washers(x2)
Springwasher
Hexagonalnut
Installation diagram
1. Remove the protective cap and tape.
[See Note 3-1]
Plate
(Metal)
Protectivetape
Protectivecap
<SpaLet bowl>
<Rear of seat unit>
2. Set the seat unit on
the SpaLet bowl.
[See Note 3-2]
3. Afxtheseatunit.
Placethewashers(two)andspringwasher
overeachxingbolt,andafxthenut.
Fastenthenutbyhand.[See Note 3-3]
Securingbolt
Washers
(x2)
Springwasher
Hexagonalnut
AlignthetipoftheSpaLetlidtothetipof
theSpaLetbowl.
Theedgeof
theSpaLet
bowlisseen.
Tightenthenutwiththeincludedtool.
(Torqueat2.0-2.5N•m
{20-25kgf•cm/1.48ft-lbto1.9ft-lb})
4. Remove the protective sheet
from the SpaLet seat.
SpaLetseatprotectivesheet
Seatunit
Alignthe
securingboltsto
theboltholes.
Turn
3 Mounting the Seat Unit
[Note 3-1]
Do not remove the plate (metal
item).
* Waterleakagemayresult.
[Note 3-2]
Checkthatthisproductisrmly
afxedtotheSpaLetbowl.
Check that there is no debris
on the SpaLet bowl or seat unit
washing water inlet.
* Waterleakagemayresult.
[Note 3-3]
Tighten the left and right
hexagonnutsalternatively
in order to ensure even
tightening.
* Waterleakagemayresult.
-9 EN-
1. Install the water supply hose to the
seat unit.
Removetheprotectivecap.
Connectthewatersupplyhose.
[See Note 4-1]
Bendthecliptormlyxthewatersupply
hosetotheseatunitwatersupplyinlet.
[See Note 4-2], [See Note 4-3],
[See Note 4-1]
• Afterafxing,rotatetheclip,andcheck
thatitisattachedproperly.
• Also,pullthewatersupplyhosegentlyto
ensurethatitisconnectedproperly.
• Theclipcanonlybeattachedinthe
specieddirectionasshowninthegure
below.[See Note 4-4]
Click
Clip(gray)
[Note 4-1]
Remove the cap on the water supply hose
water shutoff valve immediately prior to
attaching the water shutoff valve.
* Duringinstallation,debrismayenterthewater
supplyhose,resultinginavalvemalfunction.
[Note 4-2]
Take care that the O-ring is not damaged.
* IftheO-ringisbrokenorotherwisedamaged,
waterleakagemayoccur.
● Attachthecliprmly.
WrongCorrect
[Note 4-3]
Seatthecliprmlyuntilitmakesanaudibleclick.
* Waterleakagemayresult.
[Note 4-4]
Install the clip horizontally to the side of the
SpaLet body.
* Ifpushedonwithanangle,thentheclipcannot
bebenttoafxitproperly.
4 Connecting the Water Supply Hose <Seat Unit End>
Installation diagram
Watersupplyhose
Clip
(Gray)
Donotapplyexcessiveforce
when connecting the water
supply hose.
Protectivecap
Seatunitwater
supplyinlet
O-ring
[Reference 4-1]
Push the clip downward to remove the clip.
Standardscrewdriver
Clip
Holdtheclip
withafinger
Pushdownward
Clip cross-section view
-10 EN-
5
Connecting the Water Supply Hose <Water Shutoff Valve End>
1. Install the water supply hose to the
water supply inlet.
Removetheprotectivecap.
Connectthewatersupplyhose.
[See Note 5-2]
Water
supplyhose
O-ring
Watersupplyinlet
Watershutoffvalve
Protectivecap
Afxtheclipinthesamewayaswiththe
seatunitwatersupplyinlet.
[See Note 4-2], [See Note 4-3],
[See Note 4-1]
• Afterafxing,rotatetheclip,andcheck
thatitisattachedproperly.
• Also,pullthewatersupplyhosegentlyto
ensurethatitisconnectedproperly.
Click
Clip(white)
[Note 5-1]
Be careful not to impact the power plug, or
let it fall into the SpaLet bowl.
[Note 5-2]
Ensure that the water supply
hose is not bent tightly or
stretched.
Do not use a hose that has
been bent.
* Thehosemaybedamaged
resultinginwaterleakage.
* Thismayresultinincompletecleaning.
Installation diagram
Water
shutoffvalve
Water
supplyhose Water
supplyhose
O-ring
Watershutoffvalve
Water
shutoff
valve
Clip(white)
Clip(white)
Clip(white)
<Wall water supply> <Floor water supply>
[See Note 5-1]
-11 EN-
1. Connect the power plug to the outlet.
Powerplug
2. Check that the power is on.
Conrmthatthepowerindicatorontheseat
unitareilluminated.
Flush button (indicator)
Power indicator
WARNING
Ensuretheelectricaloutlettowhich
thepowercordisconnectedis
properlygrounded,asfailuretodoso
maycauseelectricshock,etc.
GROUND
6 Connecting to the Power Supply
-12EN-
7 Positioning and Mounting the Remote Control
Remote control installation position
Install the remote control to a position where
the user can reach and operate it.
Installtheremotecontrolintheareashownas“Suggestedinstallationarea”
inthegurebelow,andensuretoinstalltheremotecontrolonaposition
whereitcanbeoperatedeasilywhiletheuserisseatedontheSpaLetseat.
Unit:mm
(")
900(35-7/16)
600(23-5/8)
800(31-1/2)
1200(49)
1000(39-3/8)
Suggestedinstallationarea
Suggestedinstallationarea
foreasieroperation
Sit on the SpaLet seat and ensure the
installation position. [See Note 7-1]
Temporarily install the remote control to the target position,
and sit on the seat unit and press the [STOP] button
(ensure to perform a test operation after installation).
Then,standinfrontoftheSpaLetbowland
pushthe[STOP]buttontoensurethata
beepsoundisgeneratedfromtheseatunit.
• Donotpushthe[REARor
[FRONTWASHING]button:
waterwouldcomeoutfromthe
seatunit.
• Ensurethatthereisenoughspaceabovetheremote
controlinstallationpositiontoalloweasyremovaland
mountoftheremotecontrol.
2. Mounting the Remote Control
Installation Procedure
1.
Remove the holder from the remote control.
2. Install the holder to the installation
position using an appropriate method
for the wall. [See Note 7-2]
* Outof4slots,usetheouter2slots(withAmarks).
Iftheholdercanbe
installedonlywitha
holepitchat100mm
(3-15/16"),usetheinner
2slots.
[For a plywood wall (> 5 mm (3/16") thick)]
Afxtheholderrmlywiththesuppliedwoodscrews.
[For a plywood wall (<5 mm
(3/16")
thick) or a plaster board wall]
Makethepilotholeswith6mm(1/4")diameter.
(5mm[3/16"]
diameterfora
plasterboardwall)
Useahammerto
insertthesupplied
plasticanchorsgently.
Afxtheholder
rmlywiththe
woodscrews.
Thewoodscrewsaretightatthebeginning,
andthenloosened
onceandtightenedagain.
[For a concrete wall]
Makethepilot
holeswith6mm
(1/4")diameter
andapprox.33mm
(1-5/16")depth.
Useahammerto
insertthesupplied
plasticanchors
gently.
Afxtheholder
rmlywiththe
woodscrews.
3. Align the remote
control to the
holder, and push
downward to
mount the remote
control.
4.
Press the [Hr] and
[Min] buttons to set
the current time.
* Payattentionto
AM and PM.
100 mm
156 mm
Holder
Wood
screws
Plastic
anchors
Φ6mm
(1/4")
Holder
Woodscrews
Plasticanchors
33 mm
(1-5/16")
Φ6mm
(1/4")
Holder
Woodscrews
Holder
Remote
Control
Time setting switch
Hr Min
1.
Installing the Batteries and Confirming the Remote Control Installation Position
1. Open the back cover of the remote control, and
installtheincludedbatteries(AAAx2).[See Note 7-1]
* Useatoolsuchasaat-bladescrewdrivertopushthe
hook(lock)toremovethecover.
2. Conrmtheremotecontrolinstallationposition.
Batteries
Hook(lock)
Remotecontrol
Backcover
-13 EN-
8 Test Operation
(Follow the steps below to conduct a test operation when installation is completed.)
●Isthereanywaterleakage?
[See Note 8-1]
1. Open the water shutoff valve.
Leakage
check
Checked
Details
Isthereanyleak?
* FlushtheSpaLetseveraltimes.
(Waterleakageatthesupply/drainwaterconnecting
sectionsmaynotbeobservedunlesstheSpaLetis
flushedseveraltimes.)
Betweenthewatershutoffvalveandthewatersupply
hose
Betweenthisproductandthewatersupplyhose
BetweenthisproductandtheSpaLetbowl
BetweentheSpaLetbowlandtheoor
Dotherearwashingandfrontwashingoperateproperly?
[See Note 8-2]
1. Connect the power plug to the outlet.
2. Roll up the sleeve and place the arm so that the palm is
over the center of the SpaLet bowl.
Check
item
Checked
Details
Rear
washing
nozzle
1.Doesthewarmwaterwithanappropriate
temperaturecomeoutfromthenozzle?
Pressthe[CLEANSING]button.
Ensurethattheshowercomesoutfromthenozzletothepalm.
CLEANSING
2.
Doestheshowerstopwhenthe[STOP]buttonispressed?
Bidet
nozzle
1.Doesthewarmwaterwithanappropriate
temperaturecomeoutfromthenozzle?
Pressthe[BIDET]button.
Ensurethattheshowercomesoutfromthenozzletothepalm.
BIDET
2.
Doestheshowerstopwhenthe[STOP]buttonispressed?
3. Remove the arm from the SpaLet bowl.
[Note 8-1]
Water leakage at the supply/drain water
connecting sections may not be observed
unlesstheSpaLetisushedseveraltimes.
[Note 8-2]
This product is equipped with a seat sensor that detects
the user. In order for the rear washing and front washing
features to operate, the user must be seated.
[Note 7-1]
Ensure to install the batteries in the correct
direction (note the negative and positive).
● Donotmixoldandnewbatteries.
Use the supplied batteries.
[Note 7-2]
Ensure that there is enough space above the
remote control installation position to allow
easy removal and mount of
the remote control (see the
gurebelow).
Remotecontrolspace
45 mm
(1-3/4")
240 mm (9-7/16")
-14 EN-
9 Mounting the Side Cover
1. Attach the side covers on both sides.
[See Note 9-1], [See Reference 9-1],
[See Reference 9-2]
Insertthe“clip”ontheuppersideoftheside
coverintothe“clipholder”ontheSpaLetbowl
AlignthelinesoftheSpaLetbowlandtheside
cover,andattachthesidecovertothe“Velcro
fastener”onthelowersideoftheSpaLetbowl.
Velcrofastener
Sidecover
Clip
Clip
Clipholder
Clipholder
Pushthecenterofthesidecovertosecurethe
“Velcrofastener”rmly.
Velcrofastener
Sidecover
[Reference 9-1]
If the water shutoff valve is located on the right when facing the
SpaLet, remove the attached panel attached to the right side cover
and attach it to the left side cover.
 Removethescrewonthebackoftherightsidecover.
 Removetheattachedpanelfromtherightsidecover.
*Removeinthedirectionindicated.
 Attachtheattachedpaneltotheleftsidecover.
*Insertinthedirectionindicated.
 Insertthescrewonthebackoftheleftsidecovertofastentheattachedpanel.
[Reference 9-2]
Align the side covers to the SpaLet bowl lines when installing the side covers.
Align the lines
Screw
Sidecover
(R)
Attached
panel
Sidecover
(L)
[Note 9-1]
●  DonotforcethesidecovertotheSpaLetbowl.
* Thecovermaybedamaged.
-15EN-
(1) Closethewatershutoffvalvetostopthewatersupply.
[See Note 10-1]
(2) Pressthe[FLUSH/FULL]buttonorpresstheflushbutton
ontheSpaLetbody.
* Waitapproximately20seconds.
* Drainthewaterandremovethewaterpressureinsidethe
toiletbody.
(3) Removethesidecoverontheleft(whenfacingtheSpaLet
body).
(4) Rotateandremovethestraineronthelowerleftwhen
facingtotheSpaLet.
* Asmallamountofwatermayspilloutwhenremovingthe
strainer,soplaceapieceofclothorsimilarontheoor.
(5) Washawayalldebrisinsidethestrainerandfromthe
O-ring.
(6) Fullytightenthestrainer.
[See Note 10-2]
(7) Attachthesidecover.
(8) Connectthepowerplugtotheoutlet.
(9) Openthewatershutoffvalve.
(10)Checkforleaksfromthewatershutoffvalve.
Ifthewaterdoesnotowwell,cleanthestrainer.
[Note 10-1]
Do not remove the strainer when the water
supply valve is open.
* Waterwillleakfromthestrainer.
[Note 10-2]
When installing the strainer, make sure that the
water shutoff valve is tightened completely.
* Ifthisisnottightenedcompletely,thentheremaybe
waterleakagefromthestrainer.
[Note 10-3]
How to drain the water from the SpaLet body
* Pressboththe[POWERSAVEON/OFF]button
and[AUTOCLEAN]buttonontheremotecontrol
atthesametimeformorethan2seconds.
O-ring
Strainer
Sidecover
Strainer
Open/close
knob
Water
shutoffvalve
Close
-16EN-
1. Changing emitting signal
(remote control unit)
(1)Removethebatteriesfrom
theremotecontrolunit.
(2)Refertothesignaltable
ontheright,holddown
thedesiredbutton,insert
thebatteriesandwaitfor
sixsecondswiththebutton
helddown.
(3)Whentheemittingsignal
hasbeenchanged,the
batterymarkonthelower
rightoftheremotecontrol
unitLCDashes.
(Thenumberofashes
differsdependingon 
thesignalthathasbeen
changed.)
2.Changing receiving signal
(bidet body)
(1)Removethepowerplugof
thebidetforwhichthesignalis
tobechanged.
(2)Insertthepowerplugagain,
andthenpressthe[STOP]
buttonatleast10timeswithin
10secondsafterinsertion.
NOTE: Do not turn on and off
theindoor(equipment)breaker
toperformtheaboveoperation.
*Ifpoweristurnedon 
simultaneouslyformultiple
bidets,thereceivingsignalof
otherbidetsmaybechanged.
*Somesignalscannotbeseton
someproducts.
Signal
Number
OperationButton BatteryMark
No.ofFlashes
Signal1 WaterTemp Once
Signal2 SeatTemp Twice
Signal3 Powersave Threetimes
Signal0 NozzleCleaning Fourtimes
Signal4 Hr Fivetimes
Signal5 Min Sixtimes
Signal6 Autoclean Seventimes
Signal7 Dryertemp. Eighttimes
* Signal 0 is the default setting.
Whenmultiplebidetsareinstalled,abidetinotherboothmayalsorespondtothesignalandmalfunction.
Topreventthis,youcanchangethesignalusingtheremotecontrolunityoupurchased.Changeboththe
emittingsignal(remotecontrolunit)andreceivingsignal(bidetbody).
When multiple bidets are installed:
-1 SP-
PCW-1331-US-ASB (19010)
Gracias por comprar este producto.
PRECAUCIÓN
● Leaestemanual
deinstalación
cuidadosamente
parainstalarbienel
producto.
● Verifiqueel
funcionamientouna
vezterminadala
instalación.
Procedimiento de instalación
󱈠 Montar la taza SpaLet
↓
󱈢 Fijar la válvula de cierre del agua
↓
󱈤 Montar la unidad del asiento
↓
󱈦 Conectar la manguera de
suministro de agua <Extremo
de la unidad del asiento>
↓
󱈨 Conectar la manguera de
suministro de agua <Extremo
de la válvula de cierre del agua>
↓
󱈪 Conectar al suministro de
electricidad
↓
󱈬 Posicionar y montar el control
remoto
↓
󱈮 Probar el funcionamiento
↓
󱈰 Montar la tapa lateral
Manual de instalación
Asiento de bidé Advanced Clean 100 SpaLet®
Modelo:8017A60GRC
7302385-100 7302385-100SP
-2SP-
El manual consta de dos partes. La primera parte
contiene las precauciones de seguridad y las
descripciones de los procedimientos para instalar
el SpaLet. La segunda contiene las imágenes de la
instalación. Al usar el manual, consulte ambas partes.
PRECAUCIONES DE SEGURIDAD
Para una instalación y un uso seguros del producto,
lea las precauciones con cuidado antes de instalarlo.
PELIGRO Una situación de peligro inminente que,
de no evitarse, resultará en la muerte o
en una lesión grave.
ADVERTENCIA Una situación de peligro potencial que, de
no evitarse, podría resultar en la muerte o
en una lesión grave.
PRECAUCIÓN
Una situación de peligro potencial que,
de no evitarse, puede resultar en una
lesión menor o moderada o en un daño al
producto u otros bienes.
PELIGRO
La conexión incorrecta del enchufe de
electricidad o la toma puede causar un
choque eléctrico.
Todo el trabajo de instalación eléctrica debe
ser realizado por un electricista calicado.
Existe el peligro de cortocircuito y/o choque
eléctrico.
ADVERTENCIA
Siga las instrucciones del manual e instale el
producto correctamente.
De lo contrario, habrá un riesgo de choque
eléctrico, incendio, lesiones, fuga de agua y/o
inundación.
Únicamente un electricista certicado debe
desarmar, reparar o modicar el producto.
Hay un peligro de choque eléctrico o incendio,
y el producto podría funcionar mal y causar
una lesión.
No conecte ni desconecte el enchufe
de electricidad o la toma o el cable de
electricidad con las manos mojadas.
Hay un peligro de choque eléctrico.
Sostenga el enchufe o la toma al
conectarlos o desconectarlos.
Si el enchufe o la toma se conectan o
desconectan sosteniendo el cable, hay
un peligro de incendio o choque eléctrico
debido a un daño del enchufe, la toma
o el cable.
No vierta agua o limpiador dentro ni sobre la
unidad de asiento SpaLet, el control remoto
ni el enchufe de electricidad o toma.
Puede causar un choque eléctrico o un
incendio.
No use un suministro de electricidad
que no sea AC120V. No use ningún otro
método para conectar el enchufe o la
toma a un receptor con la conguración
incorrecta que exceda el voltaje calicado
para el uso.
Use un cable VVF (con alambre de cobre
sólidos de 20 AWG cada uno) para el
cable de electricidad. Si se usa un cable
de electricidad diferente al especicado
arriba (como alambre trenzado simple
o sujeto a las terminales, etc.), puede
resultar en sobrecalentamiento por la mala
conexión y causar corrosión, desgaste,
incendio del producto y el cable.
Conecte la electricidad por completo. Hay
un peligro de incendio o choque eléctrico
debido a un daño del cable.
No dañe, doble, modique ni gire en
exceso, amarre, intercale ni coloque
objetos pesados sobre el cable de
electricidad.
Hay un peligro de incendio o choque
eléctrico debido a un daño del cable.
No instale el producto en un lugar mojado
o húmedo, como dentro de un cuarto de
ducha o de vapor.
Hay un peligro de choque eléctrico o
incendio.
-3 SP-
No conecte el producto a ninguna fuente de
agua que no sea potable.
Puede causar choque eléctrico, un incendio e
inamación de la piel debido a la corrosión de
las partes electrónicas dentro de la unidad de
asiento.
No desarme ni modique el producto.
Puede causar un choque eléctrico o un
incendio.
No use una toma oja.
Puede causar un choque eléctrico o un
incendio.
PRECAUCIÓN
Instale un interruptor de circuito con pérdida
a tierra de alta velocidad (con un valor de
corriente calicado de 15 mA o menos) en el
lado primario del suministro de electricidad.
Hay un peligro de choque eléctrico.
La taza SpaLet® está fabricada de cerámica,
y la cerámica es frágil. Al manipular la taza
SpaLet, tenga en cuenta lo siguiente:
–– Antes de la instalación, verique que la
taza SpaLet esté en buenas condiciones y
no esté dañada.
–– Después de la instalación, verique que la
taza SpaLet no tenga daños.
De lo contrario, habrá un riesgo de lesiones,
fuga de agua y/o inundación.
Limpie con agua para eliminar todos los
materiales extraños y el óxido dentro de las
tuberías antes de conectar el producto.
De lo contrario, podrán dañarse las piezas
internas del producto y causar fuga de agua
y/o inundación.
Al usar el colador, tenga en cuenta lo
siguiente:
–– Cierre la válvula de cierre del agua
cuando retire el colador.
–– Cuando instale el colador, ajústelo por
completo para que no haya una brecha.
–– Verique que el anillo O no tenga
materiales extraños cuando lo sujete.
Si el anillo O tiene materiales extraños, puede
causar inundación por fuga de agua.
Ajuste la válvula de cierre del agua y verique
que no haya fugas de agua después de la
instalación.
Puede causar fuga de agua y/o inundación.
Si se espera que se congele el agua,
drene el agua del producto.
De lo contrario, habrá un riesgo de
incendio, fuga de agua y/o inundación
debido al daño por el congelamiento.
Drene el agua de las tuberías después
de cualquier construcción o renovación, o
cuando el suministro de agua se restaura
después de un corte.
Si el suministro de agua tiene aire, puede
causar daños o un mal funcionamiento del
producto o las tuberías. Hay un peligro de
lesiones o daño al edicio o a los muebles
por una inundación.
-4 SP-
SUMINISTRO DE ELECTRICIDAD
Instaleelcableylatomasegúnlasespecicaciones
másabajo.
Eltrabajodedistribucióndelaelectricidaddebeser
realizadoporuncontratistaelectricista.
Use un suministro de electricidad AC120V con
calificación de consumo.
Sielproductoseusaconotrosaparatoseléctricos,
configureelnúmerocorrespondientedetomas.
El cableado debe ser adecuado al consumo de
electricidadcalicado.
Coloque la toma al alcance del cable y lo
suficientemente alta como para que no llegue el agua.
El largo del cable de electricidad es 1 m (39-3/8").
 Noconecteelenchufedeelectricidadalatomahasta
completarlainstalación.Puedefuncionarmal.
SUMINISTRO DE AGUA
El inodoro SpaLet usa válvulas solenoides que son
de acción rápida o cierre rápido. Se recomienda
encarecidamente el uso de arrestadores de golpe
de ariete para este producto. Todas las tuberías
ubicadas detrás de las paredes deben sujetarse y
fijarse adecuadamente.
Use únicamente agua potable como suministro
de agua.
Elusodeunsuministrodeaguadistinto(agua
industrialodepozo,etc.)puededeteriorarla
durabilidaddeloscomponenteseléctricosymecánicos
yresultarenunaccidenteomalfuncionamiento.
La presión de agua debe ser superior a 175MPa/25
PSI (presión hidrostática) y 0.10MPa/14.5 PSI
(presión de flujo) y 17l/min. cuando fluye.
Si la presión de agua es superior a 0.75MPa/109
PSI, descomprima la presión usando una válvula
de descompresión.
ESPACIO MÍNIMO PARA LA INSTALACIÓN
Consultelaguraacontinuaciónparaconocerel
espacio mínimo requerido para la instalación.
* 1Serecomiendadejarunespaciode70mm(2-3/4")
omásdecadaladodelproducto.Siesinferiora70
mm(2-3/4"),puededicultarelfuncionamiento.
* 2Coloquelaválvuladecierredelaguaa2"(50mm)
delapared.
*1
70 (2-3/4) min.
*1
70 (2-3/4)
min.
375 (14-3/4) min.
400 (15-3/4) min.
*2
50 (2)
min. 1050 (41-5/16) min.
Remote Control
280
(11)
700 (27-9/16) min.
15 (9/16) min.
Unit: mm
(")
POSICIÓN DE INSTALACIÓN DEL CONTROL
REMOTO
a
b b
1300 mm (51-3/16")
On the left side On the right side
Instaleelcontrolremotoenlaparedizquierdamirando
launidadSpaLet,paraqueestédelmismoladoque
elreceptordelaseñaldecontrolremotolomáslejos
posible.Si,porcualquiercasualidad,elcontrolremoto
debeinstalarsedelladoderecho,verifiqueantessi
elreceptorrecibelaseñal.Además,silaparedestá
alejadadelaunidadSpaLet,porejemplo,debidoauna
disposicióncomounaconsolainstaladaentrelaparedy
launidad,esposiblequeelreceptornorecibalaseñal.
Enesecaso,levanteunapantallaquereflejelasseñales
dentrodelos1300mm(51-3/16")delcentrodelataza
SpaLet.Estapantalladebemedirporlomenos1100
mm(43-5/16")dealturaydebecubrirladistanciaentre
elreceptordeseñalylaposicióndelcontrolremotouna
vezinstalado.(Lascondicionespuedenvariarunpoco
segúnelacabadoyelcolordelapared.)
a Receptor de la señal de control remoto
b Control remoto
¡NO COLOQUE LA UNIDAD DEL ASIENTO EN EL PISO!
Nocoloquenuncalaunidaddeasientoenelpiso,yaque
puedenromperse los pernos de montaje de la unidad
del asiento o la entrada del suministro de agua.
NOTAS PARA ANTES DE LA INSTALACIÓN
No sostenga la
manguera en la parte
posterior de la taza
SpaLet.
* Siseretiralamanguera,
puede causar
fugas,yelSpaLet
nosedescargará
correctamente.
c Mangueras
c
Finished
Wall
Remote
Control
Power AC
120V
3-1/4" (82 mm)
2-9/16"
(65 mm)
7-1/16" (180 mm)
Length
39-3/8"
(1000 mm)
Length
16-1/8"
(410 mm)
14-3/4"
(375 mm)
5-15/16"
(150 mm) Drainage Pipe
9-1/16"
(230 mm) 4-3/4" (121 mm)
15-3/16"
(385 mm)
1-3/8"
(35 mm)
16-9/16"
(420 mm)
20-5/8"
(524 mm)
12"
(305 mm)
Cumple con las directrices de la Ley de Estadounidenses Dis-
capacitados y ANSI A117.1 Requisitos para las Instalaciones
Accesibles y Utilizables. Verifique los códigos locales.
15 (9/16) mín.
*1
70 (2-34) mín.
375 (14-3/4) mín.
400 (15-3/4) mín.
Control remoto
1050 (41-5/16) mín.
*1
70 (2-34) mín.
280
(11)
*2
50 (2)
mín.
700 (27-9/16) mín.
Control
remoto
Pared
terminada
Electricidad
AC 120 V
Largo 39-3/8”
(1000 mm)
Largo 16-1/8”
(410 mm)
Unidad:
mm (“) 3-1/4” (82 mm)
7-1/16” (180 mm)
14-3/4”
(375 mm)
2-9/16”
(65 mm)
20-5/8”
(524 mm)
5-15/16”
(150 mm)
9-1/16”
(230 mm) 12”
(305 mm)
4-3/4” (121 mm)
Tubería de desagüe
1-3/8”
(35 mm)
15-3/16”
(385 mm)
16-9/16”
(420 mm)
Del lado izquierdo Del lado derecho
1300 mm (51-3/16”)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

American Standard Advanced Clean 100 SpaLet Guide d'installation

Taper
Guide d'installation
Ce manuel convient également à