Pressalit M60246 Mode d'emploi

Catégorie
Moniteurs de fréquence cardiaque
Taper
Mode d'emploi

Ce manuel convient également à

SCT 1000
R8573114
R8573118
R8583114
R8583118
R8593114
R8593118
Shower change table – Operation and maintenance manual en
Bruseleje – Brugs- og vedligeholdelsesvejledning dk
Duschliege – Gebrauchs- und Pegeanleitung de
Table de douche et de change – Manuel d’utilisation et d’entretien
fr
Douchebrancards – Gebruiks- en onderhoudshandleiding nl
Duschbrits – Bruks- och underhållsanvisning sv
Dusjstellebord – Bruks- og vedlikeholdsveiledning no
Camilla de ducha - Instrucciones de uso y mantenimiento es
Stół prysznicowy – Instrukcja obsługi i konserwacji pl
洗澡床 - 操作和维护手册 中文


en The guarantee covers faults or defects in material or manufacture within a period of 3 years.

dk Garantien dækker i 3 år fra fakturadato for materiale- og fabrikationsfejl. Der tages forbe-
hold for trykfejl, tekniske ændringer og modelafvigelser.
de Die Garantie gilt für drei Jahre ab Rechnungsdatum für Material- und Herstellungsfehler.
Druckfehler, technische Änderungen und Modellabweichungen vorbehalten.
fr La garantie couvre les vices de fabrication et de matériaux pour une durée de 3 ans à partir

nl 
voorbehoud van drukfouten, technische wijzigingen en modelafwijkingen.
sv Garantin gäller i 3 år från fakturadatum för material- och fabrikationsfel. Med reservation
för tryckfel, tekniska ändringar och modellavvikelser.
no Garantien gjelder i 3 år fra fakturadato for material- og fabrikasjonsfeil. Med forbehold for
trykkfeil, tekniske endringer og modellforskjeller.
es La garantía cubre fallos de material o fabricación durante los 3 años posteriores a partir de

técnicas y varia ciones de modelo.
pl 


中文 保修涵盖 3 年内出现的材料或制造故障或缺陷。产品的技术和设计可能稍微发生变
化,恕不另行通知。

5

English ................................................................. 9
Dansk ................................................................. 27
Deutsch ............................................................... 45
Français ............................................................... 63
Nederlands ............................................................ 81
Svenska................................................................ 99
Norsk................................................................. 117
Español............................................................... 135
Polski................................................................. 153
中文 ............................................................171

 189
3
R8583114, R8593114, R8573114
R8583118, R8593118, R8573118
REF
YYYY-MM-DD
YY-MM-DD
U:XXXV
XX-XX Hz IPXX
P:X W I:XXA
RZZZZYYYXXX-X
(01)0XXXXXXXXXXXXX(10)YYMMDD
xxx kg
xxx lbs ++xxx kg
xxx lbs
xxx kg
xxx lbs
++
2
min
18
min
Pressalit A/S, Pressalitvej 1 DK-8680 Ry
+45 8788 8777, www.pressalit.com
REF
4
230V
R8583114
R8583118
120V
R8593114
R8593118
230V
R8573114
R8573118
5
R8491
R8420
R8421
6
Max P U Max I
R8583114
R8583118
R8573114
R8573118
70 W 230V 0,3A
R8593114
R8593118
36 W 120V 0.3A
++
R8583114, R8593114,
R8573114
44.46 kg, 98.01 lbs
150 kg /330 lbs
R8583118, R8593118,
R8573118
45.92 kg, 101.23 lbs
kg
lbs
7
mm
750
1170
1400
750
600
R8583114, R8593114, R8573114
750
1170
1800
600
750
R8583118, R8593118, R8573118
8
inch
29.53
46.06
55.12
29.53
23.62
R8583114, R8593114, R8573114
29.53
46.06
70.87
23.62
29.53
R8583118, R8593118, R8573118
9
en
Content
Mounting instruction ..................................................9
Operational signage ...................................................9
Symbols used in this manual...........................................10
General safety ........................................................11
Intended use .........................................................12
Intended operator profile .........................................12
Intended user profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Operating environment...........................................12
Contraindications for use .........................................12
Biocompatibility......................................................12
Operating instructions ................................................13
Safety rail .......................................................14
Height adjustment ...............................................15
Cleaning.............................................................16
Disinfection .....................................................16
Maintenance.........................................................17
Maintenance inspection ..........................................17
Trouble-shooting .....................................................19
Electromagnetic compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Electromagnetic immunity........................................20
Electromagnetic emission ........................................23
Product label.........................................................24
Technical data........................................................26
Disposal and recycling ................................................26
Original instructions
Mounting instruction
A mounting instruction is included with the product. It can also
be downloaded from www.pressalit.com.
Operational signage
An operational signage is included with the product. It can also
be downloaded from www.pressalit.com.
10
en
Symbols used in this manual
The following symbols are used in this manual as well as the associated
documentation supplied with the product.
!WARNING WARNING indicates a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
!CAUTION CAUTION indicates a potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury. It may also be used
to alert against unsafe practices.
IMPORTANT IMPORTANT indicates important
information about handling and use
of the product.
NOTICE NOTICE is used to address practices
not related to personal safety.
Hand injury
warning
Head injury
warning
Electricity /
voltage warning
Do not leave
patient
unattended
REF
Compatible
products
Power
specifications Spare parts Article number/
versions
Product weight Max. user weight
11
en
!CAUTION
• Please comply with these instructions to avoid the product becoming
damaged or destroyed.
• Do not perform repairs, disassembly, or assembly operations,
extensions, re-adjustments or modifications to this product. These
must be carried out by Pressalit or by persons authorized by Pressalit
only.
• Never allow children to operate this product unless under supervision.
The product is not intended for play.
• Never use the product if it is defective or damaged. Do not use a
defective product before it has been repaired.
!WARNING
• Read and understand the manual completely before use. Keep the
manual close to the unit.
• Comply with this manual to avoid accidents involving serious personal
injury.
• Never use or handle this product in other ways than are specified in
this manual, as this can put your safety at risk and cause damage to the
product.
• Make sure that everyone who is to install or use the product and its
systems has the necessary information and access to this manual.
NOTICE
• The information in this manual is based on correct fitting of the
product in accordance with our mounting instruction.
• Pressalit cannot be held liable if the product is used in any way which
differs from that described in the guide.
• We reserve the right to amend this manual without prior notice.
General safety
12
en
Intended use
This product is intended for bathing a person who is unable to stand up or sit
down. The person is lying horizontally on the shower table.
Intended operator profile
The product is to be used by a person trained in health care and/or trained in
washing a person in their care.
Intended user profile
The product can be used by all - adults, children, young, old, whose weight
does not exceed the maximum load of 150 kg / 330 lbs.
Operating environment
For indoor use in a wet environment, such as a bathroom or wash room.
The product is intended to be used at room temperature, in private homes,
nursing homes and hospitals under normal working conditions.
Contraindications for use
Use of the change trolley is not recommended for patients with infusion or
insulin pump, inflammatory skin diseases or patients in feverish conditions.
Patients with cardiac insufficiency, cardiovascular diseases, craniocerabral
injury, open wounds, feed or drain lines (e.g. catheter, drainage tube) may use
the change trolley only after consulting with the attending physician.
Biocompatibility
The materials in contact with the skin of the user during the intended use
have been evaluated for their content of harmful substances according to
the procedures in BS EN ISO 10993-1:2020 Biological evaluation of medical
devices – Part 1 and are therefore considered suitable for this purpose.
13
en
Operating instructions
Support the shower table using
your hand or body when folding
it down, to avoid the risk of
damage.
The built-in gas cylinder makes
it easy to fold the shower table
up against the wall after use.
NOTICE
Any serious incident that has occurred in relation to the product should be
reported to the manufacturer and the health authorities.
!CAUTION
The surface of the product may become hot and / or cold if exposed to
external sources of heat or cold (e.g. sunlight or frost).
!CAUTION
Always be careful when moving a person to and from the shower table.
Take care to avoid injury to
hands when in the vicinity
of closing mechanical parts.
14
en
Safety rail
1
1
Do not leave the patient unattended.
To pull the safety rail up: Swing the rail upwards from under the shower
table. The safety rail will automatically lock into position.
To fold the safety rail away: Release the two locks simultaneously and
swing the safety rail down under the shower table.
15
en
Height adjustment
!CAUTION
Never place objects underneath the shower table.
Press and hold the up button to raise the unit.
When the button is released, the motion stops.
Press and hold the down button to lower the unit.
When the button is released, the motion stops.
To avoid risk of strangulation, make sure that the
wired remote control is placed in its holder when not
in use.
The height adjustment is controlled by the wired remote control unit.
Take care to avoid injury to hands and head
when in the vicinity of moving mechanical
parts.
When the shower
table is installed at the
recommended height,
it can be adjusted
between 480 and 880
mm (18.9" and 34.6")
above the floor.
16
en
IMPORTANT
• Do not use an autoclave or other type of steam cleaner.
• Avoid aggressive cleaning agents containing acids.
• Never spray the product directly with a high pressure cleaner.
• Avoid use of abrasive, corrosive or chlorine-based cleaning or
disinfecting products.
The product is to be cleaned with hot water or a mild soapy cleaning agent.
A list of suitable cleaning agents tested by Pressalit can be found on
pressalit.com.
!CAUTION
Always read the material safety data sheet (MSDS) and supplied
instructions of the cleaning, disinfecting or de-scaling agent and comply
with instructions for safe use, dilution, rinsing, drying, handling and
storage of the agent.
Disinfection
When using the shower table for multiple patients, it is necessary to both
clean and disinfect the shower table between uses on different patients to
prevent the risk of cross infection. A list of suitable disinfectants can be found
at pressalit.com.
Cleaning
17
en
Maintenance
Expected service life of the shower table is 10 years, provided that
maintenance is carried out as described below:
It is recommended on a weekly basis to run the motors on the product to their
maximum positions by raising the shower table to its full height, and then
lowering it to its lowest position, so that the internal parts are lubricated.
It is recommended that maintenance inspection is done once a year.
Disconnect mains before
removing the covers.
Maintenance inspection
• Check the hinges on the shower table and the safety rail . Tighten if
necessary.
• Check the canvas for damage and replace if necessary.
1
1 3
2
2
18
en
1
1
1
1
• Remove the upper and
lower retaining screws
on the cover and remove it
carefully.
• Check the wall brackets
and tighten if necessary.
• Oil moving parts,
especially the sliding
brackets .
• Check all electrical
connections to the control
box .
• Put the unit cover back
again and tighten the
retaining screws.
• Reconnect mains.
2
2
2
2
4
3
3
19
en
Trouble-shooting
Symptom Cause Action
The shower table
does not stay in
upright position.
The gas cylinders are
defective.
Contact Pressalit or your
local dealer.
The product will not
work, even though
the remote control is
used correctly.
Fault in power supply. Check that all wires and
plugs are intact and
correctly connected.
Contact Pressalit or your
local dealer.
The shower table
runs up and down
unevenly.
The sliding brackets
are not properly
lubricated.
Oil the sliding brackets
as described under
“Maintenance.
Contact Pressalit or your dealer if the problem cannot be remedied. Do not
attempt to repair the product yourself, as this will invalidate the guarantee.
Electromagnetic compatibility
The device is suitable for use at home, at daycare centres, at day centres
for persons with physical or mental disabilities or at hospitals except near
active HF surgical equipment and RF shielded rooms with medical systems
for magnetic resonance imaging with high intensity of electromagnetic
disturbances.
The device does not have any function related to basic safety or essential
performance. In case of loss or degradation of performance due to
electromagnetic disturbances, the user can still get on and off the product.
Cable Length
Power cable 3,2 m (126")
Hand control spiral cable Approx. 5 m (197") extended
20
en
!WARNING
• Use of accessories, transducers and cables other than those specified or
provided by the manufacturer could result in increased electromagnetic
emissions or decreased electromagnetic immunity of this equipment
and result in improper function.
• Portable RF communications equipment (including peripherals such as
antenna cables and external antennas) should be used no closer than
30 cm (12 inches) to any part of the unit, including its cables, to avoid
any degradation of the performance of this unit.
• Use of this equipment adjacent to or stacked with other equipment
should be voided because it could result in improper operation. If such
use is necessary, this equipment and the other equipment should be
observed to verify that they are operating normally.
Electromagnetic immunity
Electrostatic discharge
The product must not be affected by electrical discharge
between a person and the product in such a way as to
initiate actions or render components defective.
Test
standard
Immunity test level
EN 61000-4-2 +/- 8 kV contact
+/- 2, 4, 8, 15 kV air
Radiated RF electromagnetic field
The product must not be affected by radiating RF signals,
for example from a mobile phone or radio, that could
cause the product to take action or to make components
defective.
Test
standard
Immunity test level
EN 61000-4-3 15 V/m 80 MHz to 1000 MHz (only on the front)
15 V/m 1.01 GHz to 3 GHz
80 % AM 1 kHz
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207

Pressalit M60246 Mode d'emploi

Catégorie
Moniteurs de fréquence cardiaque
Taper
Mode d'emploi
Ce manuel convient également à