18
Alde AquaClear 3030033
Installation of Alde AquaClear for Alde 3030:
1. Make sure that the fresh water pump is not on and that water pipes are drained to avoid water
leakage in unsuitable places.
2. Assemble the Alde AquaClear UV-C (g. 1, A) with the Alde Water Carbon lter (g. 1, B).
Please note that Alde Aqua Clear UV-C should be located before the Alde Water Carbon lter in
the ow direction. (See g. 3)
3. Then install the product on the pipe / hose according to the arrow in the direction of water ow,
horizontally or vertically. (When placed vertically, the water ow should be able to pump from the
bottom up through Alde AquaClear UV-C to avoid air pockets that impair the ability to clean.)
4. Connect the power cable, 12 V DC, white (+) and brown (-) so that the product receives power
when the vehicle's fresh water pump is switched on.
5. The connector with green and yellow wire is connected with the supplied extension cable (g. 1, F).
The cable is then connected to the Ext. Start switch (g. 4) and indicates whether the lter is
active on the control panel during water ow from the water pump.
6. Alde AquaClear UV-C is now ready for use. To activate Alde AquaClear in the control panel, see
the next page.
Ext. Start
g. 4
g. 3
Flow direction
Connect signal cable to
the boiler circuit board
(See g. 4)
Connection 12 V from the
vehicle's fresh water pump
12 mm JG joint for PEX hose.
(When switching to soft hoses, use
the included adapter, 3010678)
When testing fresh water in the system of new vehicles in the factory, bypass must be used,
alternatively a pipe passage instead of Alde AquaClear, to avoid water remaining for a long time and
Alde Water Carbon lter (carbon lter) life is shortened.
Fill in Year and Month for
mounted Alde Water Carbon