LIMITED WARRANTY
Your Little Giant product is guaranteed to be in perfect condition when it leaves our Factory. It is warranted against defective
materials and workmanship for a period of 12 months (90 day warranty on Models: 1-AA-OM, GKPK-SC, PP-1, PPS-1, PP-12,
PPS-12, PP-230 and Cooler King) from date of purchase by the user. No warranty on brush wear in Model 35-OM and impeller
or cam in Models PP-1, PP-12, and PP-230.
Any product that should fail for either of the above two reasons and is still within the warranty period will be repaired or
replaced at the option of Little Giant as the sole remedy of buyer. For our customers in the CONTINENTAL UNITED STATES:
Please return the defective unit, postage paid, to the factory at 301 N. MacArthur, Oklahoma City, OK 73127-6616. All defective
product returned under warranty will be fully inspected to determine the cause of failure before warranty is approved.
For our customers located elsewhere; it is not economical, due to duties and freight, to return the pump to the factory for
inspection. Please return the defective unit to any authorized distributor or dealer with a brief written explanation of the prob-
lem. If there are no apparent signs of customer abuse, unit will be repaired or replaced. If dispute arises over replacement of
the pump, the distributor or dealer is to segregate such items and hold for inspection by a representative of Little Giant Pump
Company or notify factory with details of the problem for factory disposition and settlement of warranty claim.
DISCLAIMER: THE FOREGOING WARRANTY IS AN EXCLUSIVE WARRANTY IN LIEU OF ANY OTHER EXPRESS WARRANTIES.
ANY IMPLIED WARRANTIES (INCLUDING, BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE) TO THE EXTENT EITHER APPLIES TO A PUMP SHALL BE LIMITED IN DURATION
TO THE PERIODS OF THE EXPRESS WARRANTIES GIVEN ABOVE.
Warranty will be VOID if any of the following conditions are found:
1. Sealed motor housing opened
2. Product connected to voltage other than indicated on nameplate
3. Cord cut off to a length less than three feet
4. Pump allowed to operate dry (fluid supply cut off)
5. Pump used to circulate anything other than fresh water, light oils, or other mild liquids at approximately room temperature
6. Product abuse by customer
Any oral statements about the product made by the seller, the manufacturer, the representatives or any other parties, do
not constitute warranties, shall not be relied upon by the user and are not part of the contract for sale. Seller’s and manufac-
turer’s only obligation, and buyer’s only remedy, shall be the replacement and/or repair by the manufacturer of the product as
described above. NEITHER SELLER NOR THE MANUFACTURER SHALL BE LIABLE FOR ANY INJURY, LOSS OR DAMAGE,
DIRECT, INCIDENTAL OR CONSEQUENTIAL (INCLUDING, BUT NOT LIMITED TO INCIDENTAL OR CONSEQUENTIAL
DAMAGES FOR LOST PROFITS, LOST SALES, INJURY TO PERSON OR PROPERTY, OR ANY OTHER INCIDENTAL
OR CONSEQUENTIAL LOSS), ARISING OUT OF THE USE OR THE INABILITY TO USE THE PRODUCT AND THE USER
AGREES THAT NO OTHER REMEDY SHALL BE AVAILABLE TO IT. Before using, the user shall determine the suitability of the
product for the intended use, and user assumes all risk and liability whatsoever in connection therewith.
Some states and countries do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of
incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you
specific legal rights, and you may also have other rights which vary from state to state and country to country.
The National Electric Code (in the USA) and similar codes in other countries require a Ground Fault Circuit Interrupter
(GFCI) to be installed in the branch circuit supplying fountain equipment rated above 15 volts. 115 volt GFCI’s (with various
cord lengths) are in stock, and we recommend each pump be used with a GFCI.
GARANTIE LIMITÉE
La présente garantit que votre pompe Little Giant est en parfaite condition à sa sortie de l’usine. La pompe est garantie contre
tout défaut de matériau ou de fabrication pendant une période de 12 mois (90 jours pour les Modèles: 1-AA-OM, GKPK-SC, PP-
1, PPS-1, PP-12, PPS-12, PP-230 et Cooler King) à partir de la date d’achat initial. L’usure des balais sur le modèle 35-OM ainsi que
les dommages au rotor ou à la came sur les modèles PP-1, PP-12 et PP-230 ne sont pas couverts par la présente garantie.
Tout produit encore garanti qui serait défectueux pour l’une des deux raisons sus-mentionnées sera réparé ou remplacé
à la discrétion du fabricant. L’acheteur n’aura pas d’autre recours. Pour nos clients aux ÉTATS-UNIS (territoire continental
seulement) : Veuillez retourner l’article défectueux suffisamment affranchi à l’usine à l’adresse suivante : 301 N. MacArthur
Blvd., Oklahoma City, OK 73127-6616. Tous les produits garantis retournés feront l’objet d’une inspection détaillée afin de
déterminer si la défectuosité est couverte par la garantie. Pour les clients à l’extérieur des États-Unis : étant donné les frais
de douane et de transport, il n’est pas économique de retourner la pompe à l’usine pour inspection. Expédier la pompe
ainsi qu’une brève description du problème à tout distributeur ou détaillant autorisé. Si elle ne présente aucun signe apparent
d’une mauvaise utilisation, elle sera remplacée ou réparée. S’il y a conflit sur la nécessité de remplacer la pompe, le distributeur
ou le détaillant devra garder celle-ci et, soit la fera inspecter par un représentant de Little Giant Pump Company, soit avisera
l’usine du problème afin de connaître la décision de celle-ci et le règlement de la réclamation.
DÉNÉGATION : LA GARANTIE ÉNONCÉE DANS LES PRÉSENTES EST EXCLUSIVE ET REMPLACE TOUTE AUTRE
GARANTIE EXPRESSE OU IMPLICITE; CELA COMPORTE, MAIS NON EXCLUSIVEMENT, TOUTE GARANTIE IMPLICITE
D’APTITUDE À LA COMMERCIALISATION OU D’APTITUDE PARTICULIÈRE, POUVANT S’APPLIQUER À UNE POMPE
LITTLE GIANT. DE PLUS, ELLE NE S’APPLIQUE QUE DURANT LA PÉRIODE DE COUVERTURE PRÉCISÉE CI-DEVANT.
La présente garantie sera ANNULÉE si :
1. Le boîtier scellé du moteur a été ouvert
2. Le branchement à une tension autre que celle indiquée sur la plaque du fabricant a été effectué
3. Le fil d’alimentation a été coupé à une longueur inférieure à 0,91 m (trois pieds)
4. La pompe a tourné à vide (l’alimentation en liquide a été coupée)
5. La pompe a été utilisée pour faire circuler des liquides autres que de l’eau fraîche, des huiles légères ou d’autres liquides
non corrosifs et ce, à la température ambiante
6. La pompe a été mal utilisée
Toute déclaration sur la pompe faite oralement par le vendeur, le fabricant, le représentant ou par toute autre partie ne constitue
pas une garantie et, par conséquent, ne peut servir à l’utilisateur. De plus, une telle déclaration ne peut, en aucun cas, faire
partie du contrat de vente. L’unique obligation du vendeur et du fabricant, et l’unique recours de l’acheteur, est le remplace-
ment ou la réparation de la pompe selon les modalités décrites précédemment. NI LE VENDEUR NI LE FABRICANT NE
PEUVENT ÊTRE TENUS RESPONSABLES DE TOUTE BLESSURE, TOUTE PERTE, OU TOUT DOMMAGE DIRECT, INDIRECT
OU ACCESSOIRE (INCLUANT, MAIS NON EXCLUSIVEMENT, LES VENTES OU PROFITS PERDUS, LES ATTEINTES
AUX PERSONNES OU À LA PROPRIÉTÉ OU TOUTE AUTRE PERTE INDIRECTE OU ACCESSOIRE) RÉSULTANT DE
L’UTILISATION OU DE L’INCAPACITÉ D’UTILISATION DE LA POMPE, ET L’ACHETEUR CONVIENT QU’IL NE DISPOSE
D’AUCUN AUTRE RECOURS. L’acheteur doit s’assurer que la pompe convient à l’usage projeté; il assume aussi tout
risque et toute responsabilité relativement à cet usage.
Certaines juridictions ne permettent pas la limitation de la durée d’une garantie ou l’exclusion ou la limitation de responsabilité
pour des dommages indirects ou accessoires. Par conséquent, il est possible que la limitation ou l’exclusion indiquée
précédemment puisse ne pas être applicable. Cette garantie vous donne des droits particuliers et peut-être d’autres,
dépendamment des juridictions en vigueur.
Le code national de l’électricité et autres codes semblables d’autres pays exigent l’installation d’un interrupteur avec mise
à la terre (GFI) sur le circuit d’alimentation de la fontaine pour toute installation dont la tension est supérieure à 15 volts.
Nous offrons de tels interrupteurs (avec différentes longueurs de fil) et nous recommandons que chaque pompe soit reliée
à un interrupteur de ce type.
GARANTIA LIMITADA
El producto que Little Giant le ofrece está garantizado a estar en perfectas condiciones al momento de salir de la fábrica.
El producto está garantizado contra materiales y fabricación defectuosa por un período de 12 meses (una garantía de
90 días para los Modelos: 1-AA-OM, GKPK-SC, PP-1, PPS-1, PP-12, PPS-12, PP-230 y Cooler King) desde la fecha en la
cual fue comprada por el usuario. No hay garantía contra el gasto del cepillo del Modelo 35-OM e impulsor o leva en los
Modelos PP-1, PP12 y PP-230.
Cualquier producto que falle por alguna de las dos razones anteriores y que esté dentro del período de garantía será
reparado o reemplazado a opción de Little Giant y éste será el único remedio del comprador. Para nuestros clientes en
los ESTADOS UNIDOS CONTINENTALES: Por favor, devolver la unidad defectuosa, con el porte pagado, a la fábrica en P.
O. Box 12010, Oklahoma City, OK 73127-6616. Todo producto defectuoso devuelto bajo la garantía será cuidadosamente
inspeccionado para determinar la causa de la falla antes de aprobar la garantía. Para nuestros clientes ubicados en otros
lugares; no es económico devolver la bomba a la fábrica para que ésta sea inspeccionada, debido a los impuestos y al
flete. Por favor, devuelva la unidad defectuosa a cualquier distribuidor o vendedor autorizado con una breve explicación
por escrito del problema. Si no existen señas aparentes de abuso por parte del cliente, la unidad será reemplazada o
reparada. Si se produce una disputa sobre el reemplazo de la bomba, el distribuidor o vendedor debe separar los artículos
y retenerlos para que sean inspeccionados por un representante de Little Giant Pump Company o avisarle a la fábrica de
los detalles del problema para que la fábrica disponga de las acciones necesarias y resuelva el reclamo de la garantía.
DESAUTORIZACION: LA GARANTIA ANTERIOR ES UNA GARANTIA EXCLUSIVA EN LUGAR DE CUALQUIER OTRA
GARANTIA EXPRESA. CUALQUIER GARANTIA IMPLICADA (INCLUYENDO PERO NO LIMITADO A CUALQUIER GARANTIA
IMPLICADA DE COMERCIALIZACION O APTITUD PARA PROPOSITO PARTICULAR) EN LA MEDIDA EN QUE SE PUEDA
APLICAR A UNA BOMBA, QUEDARA LIMITADA EN DURACION A LOS PERIODOS DE GARANTIAS PROPORCIONADOS
ANTERIORMENTE.
La garantía será declarada NULA si se encuentran cualesquiera de las siguientes condiciones:
1. El alojamiento sellado del motor abierto
2. El producto conectado a un voltaje que no es el indicado en la placa principal
3. El cable cortado a menos de tres pies (0,91 m.)
4. Se permitió que la bomba opere en seco (envío de fluido cortado)
5. La bomba empleada para hacer circular cualquier otra sustancia que no sea agua fresca, aceites livianos u otros
líquidos livianosaproximadamente a temperatura ambiente
6. Abuso del producto por parte del cliente
Cualquier declaración oral acerca del producto hecha por el vendedor, fabricante, representantes o cualquiera de las
partes, no constituyen garantías, el usuario no debe confiarse de ellas, y no forman parte del contrato de compra-venta.
La única obligación del vendedor y del fabricante y el único remedio para el comprador, será la reposición y/o reparación
del producto por parte del fabricante bajo las condiciones descritas anteriormente. NI EL VENDEDOR NI EL FABRICANTE
SE HACEN RESPONSABLES DE NINGUNA LESION, PERDIDA O DAÑO, DIRECTO, INCIDENTAL O CONSECUENTE
(INCLUYENDO, PERO SIN LIMITARSE A, DAÑOS INCIDENTALES O CONSECUENTES DEBIDO A GANANCIAS
PERDIDAS, VENTAS PERDIDAS, DAÑOS A PERSONAS O PROPIEDADES O CUALQUIER OTRA PERDIDA INCIDENTAL
O CONSECUENTE), QUE RESULTE DEL USO O DE LA IMPOSIBILIDAD DEL USO DEL PRODUCTO, Y EL COMPRADOR
ACUERDA QUE NO EXISTE OTRO REMEDIO DISPONIBLE PARA EL. Antes de usar, el usuario debe determinar si el pro-
ducto se adapta al uso deseado, y el usuario asume todos los riesgos y responsabilidades en relación a ello.
Algunos estados y países no permiten limitaciones sobre la duración de una garantía implícita o la exclusión o limitación de
daños incidentales o consecuentes, de manera que las limitaciones o exclusiones anteriores podrían no tener aplicación en
su caso. Esta garantía le da derechos legales específicos, y usted podría disponer también de otros derechos que varían
de un estado a otro y de un país a otro.
El Código Eléctrico Nacional (en los Estados Unidos) y códigos similares en otros países requieren un Interruptor de circuito
de falla de conexión a tierra (GFCI) para ser instalado en el circuito secundario que suministra equipo de fuente calibrado por
encima de 15 voltios. En el almacén se encuentran GFCI de 115 voltios (con varias longitudes de cable), y recomendamos
que cada bomba sea usada con un GFCI.
Figure 6
REPLACEMENT PARTS • PIÉCES DE RECHANGE • LISTA DE PARTES
ITEM P/N DESCRIPTION • NOMENCLATURE • DESCRIPCIÓN QTY.
1 105902 Switch Housing/Boîtier du contacteur/Caja del interruptor 1
2 105903 Switch Housing Cover/Couvercle, Boîtier du contacteur/Cubierta de la caja del interruptor 1
3 951060 Wiring Harness/Faisceau de câblage/Conjunto de cables (18' 115V) 1
3 951056 Wiring Harness/Faisceau de câblage/Conjunto de cables (25' 115V) 1
4 108202 Bracket/Patte D’attache/Soporte 1
5 108125 Diaphragm Assembly/L’assemblée de Diaphragme/La Asamblea de Diafragma 1
6 902404 Screw/Vis/Tornillo, #8 x 3/8" 1
7 950324 Switch/contacteur/interruptor 1
8 902512 Screw/Vis/Tornillo, #10 x 3/4" 4
9 902513 Screws/Vis/Tornillo #10 x 1-1/8" 2
10 901513 Screws/Vis/Tornillo #10 x 1" 2
11 950903 Ty-Wrap Nylon Fastener*/Attache en Nylon*/Abrazadera de Nilón* 2
*Not shown/Non illustré/No se muestra
TROUBLESHOOTING • INFORMATION SUR LA RELÈVE DES DÉRANGEMENTS • INFORMACION DE INVESTIGACION DE AVERIAS
PROBLEM • FONCTIONNEMENT DÉFECTEUX • PROBLEMA PROBABLE CAUSES • CAUSES PROBABLES • CAUSAS PROBABLES CORRECTIVE ACTIONS • SOLUTIONS • SOLUCION
Pump does not shut off. NOTE: Before troubleshooting
automatic control, check to see that pump operates on
manual control. To do this, create a slight vacuum on
breather tube (near plug), then close off tube with thumb,
plug into wall outlet. If pump works, proceed to check
switch; if not, fault is in pump or power supply.
Le moteur de la pompe ne s’arrête pas. NOTE: Avant de
tenter de réparer la commande automatique, s’assurer que
la pompe fonctionne sous commande manuelle. Pour ce
faire, créer un faible vide dans le tube reniflard (près de la
prise), fermer le tube avec le pouce, puis brancher la pompe.
Si elle fonctionne, continuer la vérification de l’interrupteur.
Sinon, c’est la pompe ou le bloc d’alimentation qui est
défectueux.
La bomba no se apaga. NOTA: Antes de localizar las averías
con el control automático, compruebe que la bomba funciona
con el control manual. Para hacer esto, cree un pequeño
vacío en el respiradero (cerca de la clavija), luego tapone el
tubo con el pulgar y conecte la clavija a una toma de pared.
Si la bomba funciona, proceda a comprobar el interruptor;
si no, el fallo está en la bomba o en el suministro de energía.
Diaphragm switch. •C’est le commutateur de diaphragme. • Interruptor del diafragma. Replace switch • Remplacer le commutateur. • Cambie el interruptor.
Weak or hardened rubber diaphragm. • Le caoutchouc du diaphragme est faible ou
durci. • Diafragma de caucho debilitado o endurecido.
Replace rubber diaphragm. • Remplacer le caoutchouc du diaphragme. • Cambie el diafragma de caucho.
Plugged vent tube. • Le tuyau de purge est branché. • Tubos de aspiración ocluídos. Clear vent tube of any obstructions. • Nettoyer le tuyau de purge. • Despeje el tubo de aspiración de cualquier obstrucción.
Dirt or sediment lodged between retainer ring and rubber diaphragm causing con-
tacts to remain closed. • Boue ou résidus logés entre le jonc et le caoutchouc du
diaphragme empêchent les contacts de s’ouvrir. • El sucio o sedimento atrapado
entre el anillo de retención y el diafragma de caucho causa que los contactos
permanezcan cerrados.
Clean area around rubber diaphragm. • Nettoyer le contour de caoutchouc du diaphragme. • Limpie el área que rodea el diafragme de caucho.
Pump is air locked. • Poche d’air dans la pompe. • Burbujas de aire en la bomba. Shut power off for approximately 1 minute, then restart. Repeat several times to clear air from pump. If system includes a check valve, a 3/16" hole should be drilled in discharge
pipe approximately 2" above discharge connections.• Couper le courant pendant 1 minute environ puis recommencer. Répéter cette opération plusieurs fois pour évacuer l’air de
la pompe. S’il y a une soupape d’arrêt, percer un trou de 3/16 po dans letuyau d’écoulement, à environ 2 po au-dessus des connexions d’écoulement. • Desconecte la electricidad
durante un minuto, aproximadamente. Luego, vuélvala a conectar. Repita varias veces, para purgar el aire de la bomba. Si el sistema tiene un válvula de retención, debe perforarse un orifi-
cio de ventilación en el tubo de descarga, aproximadamente 2 pulgadas por encima de las conexiones de descarga.
Liquid inflow matches pump capacity. • Afflux de liquide correspondant au volume de la
pompe. • El caudal que entra es igual a la capacidad de la bomba.
Larger pump required. • Une pompe plus puissante est nécessaire. • Se requiere una bomba mayor.
Defective switch. • Commutateur défectueux. • Interruptor defectuoso Disconnect switch, check w/ohmmeter, Open-infinitive resistance, closed-zero. • Débrancher le commutateur, vérifier avec un ohmmètre. Ouvert-résistance infinitive, fermé-zéro. •
Desconecte el interruptor e inspecciónelo con el ohmímetro; abierto, resistencia infinita; cerrado, cero.
Loose connection in level control wiring. • Connexion des fils électriques du niveau
de contrôle distendue. • Conexiones flojas en los cables del regulador de nivel.
Check control wiring.• Vérifier le circuit électrique. • Inspeccione los cables del regulador.
Pump runs but does not discharge liquid.
La pompe fonctionne mais il n’y a pas d’écoulement de
liquide.
La bomba funciona, pero no descarga líquido.
Check valve installed backwards. • Montage à l’envers de la soupape d’arrêt
• Válvula de retención montada al revés
Check flow indicating arrow on check valve body to insure it is installed properly. • Vérifier la fléche indiquant l’écoulement pour s’assurer que la soupape d’arrêt est bien montée.
• Inspeccione la flecha indicadora del flujo en el cuerpo de la válvula de retención, para cerciorase de que se encuentre instalada correctamente.
Check valve stuck or plugged. • Soupape d’arrêt bloquée ou obstruée. • Válvula
de retención atorada u ocluída.
Remove check valve and inspect for proper operation. • Démonter et vérifier la soupape d’arrêt pour un bon fonctionnement. • Quite la válvula de retención, y verifique que
funcione debidamente.
Lift too high for pump. • Aspiration trop puissante pour la pompe. • Altura de
impulsión excesiva para la bomba.
Check rating table. • Vérifier le tableau d’évaluation. • Estudie la tabla de capacidad.
Inlet to impeller plugged. • Arrivée de la roue à aubes obstruée. • Toma de la
rueda móvil conectada.
Pull pump and clean. • Tirer la pompe pour la nettoyer. • Saque la bomba y límpiela.
Pump is air locked. • Présence d’une poche d’air dans la pompe. • La bomba
está llena de burbujas de aire.
(See corrective action above.) • (Voir ci-dessus la solution.) • (Remítase a la solución anterior.)
Pump does not deliver rated capacity.
La pompe ne pompe pas le volume normal.
La bomba no impele a su capacidad normal.
Lift too high for pump. • Aspiration trop puissante pour la pompe. • Altura de
impulsión excesiva para la bomba.
Check rated pump performance. • Vérifier les caractéristiques techniques de la pompe. • Verifique el rendimiento normal de la bomba.
Low voltage, speed too slow. • Voltage et vitesse pas assez puissants. • Voltaje
demasiado bajo, velocidad demasiado baja.
Check for proper supply voltage to make certain it corresponds to nameplate voltage. • S’assurer que le voltage correspond bien à celui mentionné sur la plaque. • Verifique
que el suministro de electricidad sea adecuado, para cerciorarse de que corresponde al voltaje indicado en la placa del fabricante.
Impeller or discharge pipe is clogged. • Obstruction de la roue à aubes ou du tuyau
d’écoulement. • La rueda móvil en el tubo de descarga está ocluída.
Pull pump and clean. Check pipe for scale or corrosion. • Tirer la pompe pour la nettoyer. Vérifier la présence de dépôts ou de corrosion dans les tuyaux. • Saque la bomba y
límpiela. Inspeccione el tubo, en busca de capas de óxido o corrosión.
Impeller wear due to abrasives. • Usure de la roue à aubes due aux abrasifs.
• Desgaste de la rueda móvil, debido a abrasivos.
Replace worn impeller. • Remplacer la roue à aubes usée. • Cambie la rueda móvil gastada.
Pump cycles continually.
La pompe recommence son cycle sans s’arrêter.
La bomba se enciende y apaga continuamente
No check valve in long discharge pipe allowing liquid to drain back into sump.
• Absence de soupape d’arrêt dans le grand tuyau d’écoulement ainsi permettant
l’écoulement du liquide dans le puisard de réception. • Falta la válvula de retención
en el tubo de descarga largo, lo cual permite que el líquido refluya a la sumidero.
Install a check valve in discharge line. • Installer une soupape d’arrêt sur le tuyau d’écoulement. • Instale una válvula de re
tención en la tubería de descarga.
Check valve leaking. • Fuite à la soupape d’arrêt. • Escape en la válvula de
retención.
Inspect check valve for correct operation. • Vérifier la soupape d’arrêt pour obtenir un bon fonctionnement. • Verifique que la válvula de retención funcione correctamente.
Basin too small for inflow. • Bassin de réception trop petit pour l’afflux. • El fondo
del sumidero es muy pequeño o está inundado.
Install larger basin. • Installer une bassin de réception plus grand. • Instale un sumidero con un fondo mayor.
Form 993976 - 05/2006
©2008 Franklin Electric Co., Inc.
Little Giant® is a registered trademark of Franklin Electric Co., Inc.