Arjo Malibu Quick Reference Manual

Taper
Quick Reference Manual
Malibu/Sovereign
08.AZ6.03_1EN • 07/2020 • Page 1/2
QUICK REFERENCE GUIDE – FUNCTIONS
Emergency stop
Scalding protection
$XWR¿OO
Patient lock-out
Temperature display
Press button to stop all functions.
Turn clockwise to release.
Shows current bathtub water
temperature.
Shows the temperature of the
DFWLYH¿OOLQJRUVKRZHU
The electronic scalding
protection shuts off the water if a
dangerous temperature level is
detected.
The LED between the displays
lights up if a temperature above
or equal to 45 °C (113 °F) after
10 seconds is detected.
7KHDXWRÀXVKIXQFWLRQSUHYHQWV
stagnating water in the shower system.
7KHDXWRÀXVKIXQFWLRQZLOOVWDUW
30 hours after the last use of the
bathtub and then every 24 hours if the
bathtub is not used.
7KHDXWR¿OOIXQFWLRQKDVDSUHVHWZDWHUOHYHO
$FWLYDWHLWE\SXVKLQJWKHDXWR¿OOEXWWRQ
2QFHWKH¿OOLQJOHYHOLVUHDFKHGLWVWRSVE\LWVHOI
3XVKWKHDXWR¿OOEXWWRQDJDLQDQG¿OOLQJFRQWLQXHV
for another 60 seconds.
To aviod water spillage the
shower handle should be
placed in the holder after
every use.
Push and hold the patient lock out
button (A) for 3 seconds to disable
all panel and remote buttons.
Patient lock-out is indicated by a
yellow LED (B).
Push and hold for 3 seconds to
re-enable all functions.
QUICK REFERENCE GUIDE – FUNCTIONS
Emergency stop
$XWRÀXVK
1 2 3
Air spa system (optional feature)
Push the Air spa system
ON/OFF button again to
stop.
Push the Air spa system
ON/OFF button, the
air blower will start at
minimum speed.
The intensity of the air
stream will increase
by pushing the button
again.
The massage effect is obtained by injecting air through
air jets into the bath water. The recommended maximum
treatment with the Air spa system is 15 minutes.
Hand control – Lift in Hand control – Lift out
Push and hold the Lift in button
(A). The lift arm will complete a full
sequence of movement; from outside
the bathtub, over the bathtub edge
and into the bathtub.
Push and hold the Lift out
button (B). The sequence will be
performed in the reverse order.
The bathtub must be in the lowest
position.
A
B
A
B
08.AZ6.03_1EN • 07/2020 • Page 2/2
ArjoHuntleigh AB
Hans Michelsensgatan 10
211 20 Malmö, Sweden
www.arjo.com
Malibu/Sovereign
QUICK REFERENCE GUIDE – FUNCTIONS
$WWDFKVHDW
Remove seat
$WWDFKDUPUHVW Remove armrest
2
1
2
1
1
1
2
2
3
3
4
With both hands start pushing the
front end of the seat against the
front frame.
With both hands detach the seat
on each side around the armrest.
Hold the armrest with the
handle pointing up wards.
Guide the armrest slots onto the
transfer chair (1).
Fold the arm rest forward (2).
Push down the bent part of the
seat.
Repeat on the other side.
Push one side around the armrest
and make sure it snaps into place.
Pull the bottom of the seat
straight up.
Repeat on the other side.
Safety belt
Adjust safety belt
Attach safety belt.
Unlock fastening clip. Pull the
fastening clips (A) and (B) apart by
twisting the smaller fastening clip (A)
slightly upwards.
Lock fastening clip. Lock the
fastening clips by inserting the
smaller fastening clip (A) into the
larger fastening clip (B).
Buckle safety belt.
Loosen the safety belt. Pull
the inner strap (A) at the
side while lifting the larger
fastening clip (B).
Unbuckle safety belt.
Tighten the safety belt. Pull
the outer strap (A) at the
side while holding the larger
fastening clip (B).
A
A
A
A
B
B
B
B
  • Page 1 1