MEDC DB4B Le manuel du propriétaire

Catégorie
Haut-parleurs de la barre de son
Taper
Le manuel du propriétaire
Loudspeaker - DB4B
Technical manual
ii LOUDSPEAKER - DB4B TM252 Issue D May 2019 www.eaton.com
DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY
The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporations
(“Eaton”) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales
office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in
appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser.
THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE
SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE
ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY
ANY CONTRACT BETWEEN THE PARTIES.
In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or
other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to
damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the
use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the
information, recommendations and descriptions contained herein. The information contained in this manual is subject to
change without notice.
iii
Loudspeaker - DB4B
English
LOUDSPEAKER - DB4B TM252 Issue D May 2019 www.eaton.com
Contents
1.0 INTRODUCTION ........................ 1
2.0 GENERAL SAFETY MESSAGES AND WARNINGS ...................1
3.0 INSTALLATION ................................................1
Access to terminals .................................................1
Wiring details. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
4.0 OPERATION .........................................................................3
5.0 MAINTENANCE ......................................................................4
6.0 CERTIFICATION/APPROVALS ...........................................................5
IECEx units ................................................................................ 5
Gas (G) certified units
........................................................................ 5
Gas & dust (GD) certified units
................................................................. 5
ATEX units
................................................................................. 5
Gas (G) certified units
........................................................................ 5
Gas & dust (GD) certified units
................................................................. 6
These units also have the following approvals:
..................................................... 6
7.0 SPECIAL CONDITIONS FOR SAFE USE ...................................................6
8.0 FUNCTIONAL SAFETY ................................................................7
Introduction ................................................................................ 7
Conditions of safe use
........................................................................ 8
iv
LOUDSPEAKER - DB4B TM252 Issue D May 2019 www.eaton.comiv
1LOUDSPEAKER - DB4B TM252 Issue D May 2019 www.eaton.com
Loudspeaker - DB4B
English
1
1.0 Introduction
This range of loudspeakers, intended for use in potentially
explosive gas and dust atmospheres, has a power rating
of up to 25 watts and is available in versions suitable for
use in the following gas/dust groups:
The range is available in versions suitable for use in either
gas (G) or gas and dust (GD) groups.
ote:N (G) unit has nominally 6dB higher output than
(GD)unit.
The Ex enclosure is manufactured from a UV stable
glass reinforced polyester with a rugged thermoplastic
flare. Stainless steel mounting bracket, cover screws
and fixings are incorporated throughout thus ensuring
acorrosion free product.
An optional Ex e terminal chamber is available (see
certification section for further details).
An uncertified version is available for use in non-explosive
atmospheres.
2.0 General safety messages and
warnings
All instructions and safety messages in this manual must
be followed to allow safe installation of the device. The
device must only be installed and maintained by correctly
trained site personnel/installers.
I. To reduce the risk of ignition of hazardous
atmospheres and shock, do not apply power to
the device until installation has been completed
and the device is fully sealed and secured.
II. To reduce the risk of ignition of hazardous
atmospheres and shock, keep device tightly closed
when the circuit is energised.
III. Before removing the cover for installation or
maintenance, ensure that the power to the device
is isolated.
IV. Following installation, test the device to ensure
correct operation.
V. Following installation ensure a copy of this manual
is made available to all operating personnel.
VI. When installing the device, requirements for
selection, installation and operation should be
referred to e.g. IEE Wiring Regulations and the
‘National Electrical Code’ in North America. Additional
national and/or local requirements may also apply.
VII. Cable termination should be in accordance
with the specification applying to the required
application. MEDC recommends that all cables
and cores should be correctly identified. Please
refer to the wiring diagram in this manual (or
separate diagram provided with the unit).
VIII. Ensure that only the correct listed or certified
cable glands are used and that the assembly is
shrouded and correctly earthed.
IX. Ensure that only the correct listed or certified
stopping plugs are used to blank off unused gland
entry points and that the NEMA/IP rating of the
unit is maintained.
X. MEDC recommend the use of a sealing compound
such as HYLOMAR PL32 on the threads of all
glands and stopping plugs and/or a suitable
sealing washer in order to maintain the IP rating
of the unit.
XI. On Exde units, a suitable sealing washer must be
fitted to all glands and stopping plugs fitted into
the Exe enclosure.
XII. The end user or installer shall ensure that this
equipment is protected against external influences
which could adversely affect the explosion
protection, or contact the manufacturer if in
doubt of the suitability of this equipment in the
environment in which it is to be installed.
XIII. Ex d Units
The internal earth terminal must be used for
protective earthing when required. Do not remove
the internal ground strap from the earth terminal.
For units with metric entries; gland continuity and
earthing may be achieved with an optional external
earth plate. If the external plate is fitted, a thread
sealing compound such as HYLOMAR PL32 must
be employed to maintain the IP rating of the unit.
An additional internal stud is provided for a noise-
less (clean) earth connection
where local codes
or authorities permit or require such a connection.
Ex d e Units
The internal/external earth stud must be used for
equipment grounding when required. Gland conti-
nuity is achieved if the optional internal earth plate
is fitted.
XIV.
When installing the device, MEDC recommends
the use of stainless steel fasteners. Ensure that all
nuts, bolts and fixings are secure.
XV.
The unit should be positioned such that debris,
dust or water cannot settle in the re-entrant horn.
XVI.
The unit should be positioned such that any solid
object, not part of the equipment, is a minimum of
40mm from the Ex d flamepath joint.
XVII.
The purchaser should make the manufacturer
aware of any External effects or Aggressive
substances that the equipment may be exposed
to
3.0 Installation
The unit is mounted via 2 off Ø9mm fixing holes in the
U-shaped stirrup/mounting bracket. If required, the unit
can be initially placed via the Ø13mm central hole in the
stirrup. The unit can then be rotated to the required posi-
tion and fixed via the other holes.
If ordered with the unit, a swivel mounting bracket option is
available to allow further rotational adjustment to the unit.
The fixing holes have been designed to accept an M8
screw or bolt.
Access to terminals
On Ex d versions, the cover is secured with 6 off M5
cover screws (4.0mm A/F hexagon key). Once the cover
2 LOUDSPEAKER - DB4B TM252 Issue D May 2019 www.eaton.com
Loudspeaker - DB4B
English
2
fixings are unscrewed, the cover can be lifted away from
the enclosure to gain access to the interior. The cover
fixings are captive and will remain in the cover.
On Ex de versions the removable cover is secured using 3
off M5 cover screws (4.0mm A/F hexagon key). Once the
cover fixings are unscrewed, the cover can be lifted away
from the enclosure to gain access to the interior. The cover
fixings are captive and will remain in the cover. All terminal
screws, used and unused, shall be tightened down.
Once termination is complete, carefully replace the cover
assembly back onto the body, avoiding damage to the
mating surfaces. Tighten the cover screws evenly. On Ex
de certified versions, ensure the maximum torque value for
the cover screws is observed, as marked on the Ex e cover.
Ensure the O-ring is seated correctly on the cover during
re-assembly. On Ex d certified versions, ensure the required
maximum gap of 0.04mm is maintained between the cover
and the base once assembled.
Wiring details
DB4B Standard wiring DB4B Standard Ex de wiring
For standard units, connect power connections to
numbered terminals to obtain power tapping required
(see section 4 for tapping table). For loop-out connections,
use second set of numbered terminals.
DB4B 8Ohm Ex d wiring DB4B 8Ohm Ex de wiring
For direct connection 8 Ohm units, connect power from
amplifier to terminals as detailed, taking note of maximum
Loudspeaker rating. Use second pair of terminals for
loop-out connections as required.
For standard units, connect power connections to numbered terminals to obtain power tapping required (see section 4
for tapping table). For loop-out connections, use second set of numbered terminals.
For direct connection 8 Ohm units, connect power from amplifier to terminals as detailed, taking note of maximum
Loudspeaker rating. Use second pair of terminals for loop-out connections as required.
3LOUDSPEAKER - DB4B TM252 Issue D May 2019 www.eaton.com
Loudspeaker - DB4B
English
DB4B Ex d wiring with optional cap AND/OR PPTC DB4B Ex de wiring with optional cap AND/OR PPTC
Ex d units:
Connect 100V line connections to terminals marked ‘line’
on PCB, looping-out as required. Use supplied flying lead
along with common loop-in, loop-out connections to select
required power level (see section 4 for tapping table).
Ex de units:
Connect 100V line connections to terminals 1 and 2 (loop-in,
loop-out). If loop-in, loop-out functionality is required, the
two common leads must be joined together using a single
crimped bootlace ferrule. Use the supplied flying lead along
with the common lead to select required power level (see
section 4 for tapping table).
4.0 Operation
The line voltage and power rating of the unit is stated on
the unit label. The speaker is available in 3 standard power
ratings from 8 watts to 25 watts and in Ex d or Ex de
versions. Different sound levels can be obtained by selecting
the transformer tappings in the unit. See table below
for details.
Alternatively if requested when ordered, the unit can be
supplied with a direct 8Ohm connection to the driver for
connecting to a suitable audio source.
Transformer tappings
Power (W)
25W 15W 8W
1:2 25.0 15.0 8.0
2:3 12.5 7.5 4.0
3:4 6.0 5.0 2.0
1:3 4.0 4.0 1.5
2:4 2.0 2.0 0.7
1:4 1.0 0.8 0.4
4 LOUDSPEAKER - DB4B TM252 Issue D May 2019 www.eaton.com
Loudspeaker - DB4B
English
4
General arrangement
5.0 Maintenance
During the working life of the unit, it should require little or no maintenance. GRP will resist attack by most acids, alkalis
and chemicals and is as resistant to concentrated acids and alkalis as most metal products.
However, if abnormal or unusual environmental conditions occur due to plant damage or accident etc., then visual
inspection is recommended.
See below diagram for details of the flameproof joints found in the unit. WARNING!The flameproof joints detailed
below are not intended to be repaired.
FLAMEPATH - 9.5 MIN.
INSIDE SCREW HOLES
Ex d COVER/ENCLOSURE
FLAMEPATH
GLAND ENTRY
18 MIN. WALL THICKNESS
UP TO 2 POSITIONS
CABLE ENTRY
DETAIL
5LOUDSPEAKER - DB4B TM252 Issue D May 2019 www.eaton.com
Loudspeaker - DB4B
English
5
If the unit requires cleaning, then only clean exterior with
a damp cloth to avoid electro-static charge build up.
If a unit fault should occur, then the unit can be repaired
by MEDC.
If you acquired a significant quantity of units, then it
is recommended that spares are also made available.
Please discuss your requirements with the Technical Sales
Engineers at MEDC.
REF Description Part no.
10 Ex d cover screws (6 off required) PX99901028
20 Ex d cover (including seal & screws) PX99902304
30 Main flare (Long version, incl. screws & seal)* Contact MEDC*
40 Main flare screws (4 off required) PX99902305
50 Main flare seal (only required for long flare) PX99902306
60 Mounting bracket Contact MEDC
70 Mounting bracket fixing set PX99902307
80 Main flare (short version, incl. screws & seal)* Contact MEDC*
90 Ex de cover (including seal) PX99902308
100 Ex de cover screws (3 off required) PX99901028
* Note: for items 30 & 80, ensure to supply MEDC with serial number(s) from unit(s) for reference.
6.0 Certification/approvals
IECEx units
Gas (G) certified units
Certified to IEC60079-0, IEC60079-1 and IEC60079-7
Ex d IIC unit (IEC certification No. IECEx BAS 13.0112X)
Ex db IIC T
G
(T
amb.
) Gb
Ex de IIC unit (IEC certification No. IECEx BAS 13.0114X)
Ex db eb IIC T
G
(T
amb.
) Gb
See special conditions for safe use for ambient temperature
ranges and T-ratings.
The IECEx certificate and product label carry the IECEx
equipment protection level marking:
Gb
Where Gb signifies suitability for use in a Zone 1 surface
industries area in the presence of gas.
Gas & dust (GD) certified units
Certified to IEC60079-0, IEC60079-1, IEC60079-7 and
IEC60079-31
Ex d IIIC unit (IEC certification No. IECEx BAS 13.0113X)
Ex db IIC T
G
(T
amb.
) Gb
Ex tb IIIC T
D
(T
amb.
) Db IP6X
Ex de IIIC unit (IEC certification No. IECEx BAS 13.0115X)
Ex db eb IIC T
G
(T
amb.
) Gb
Ex tb IIIC T
D
(T
amb.
) Db IP65/66*
*depending on outer flare type (Short flare – IP65, Long
flare – IP66)
See special conditions for safe use for ambient temperature
ranges and T-ratings.
The IECEx certificate and product label carry the IECEx
equipment protection level markings:
Gb and Db
Where Gb signifies suitability for use in a Zone 1 surface
industries area in the presence of gas.
Db signifies suitability for use in a Zone 21 surface
industries area in the presence of dust.
ATEX units
Gas (G) certified units
Certified to EN60079-0, EN60079-1 and EN60079-7
Ex d IIC unit (ATEX certification No. Baseefa13ATEX0229X)
Ex db IIC T
G
(T
amb.
) Gb
Ex de IIC unit (ATEX certification No. Baseefa13ATEX0232X)
Ex db eb IIC T
G
(T
amb.
) Gb
See special conditions for safe use for ambient temperature
ranges and T-ratings.
The ATEX certificate and product label carry the ATEX group
and category marking:
II 2G
Where:
Signifies compliance with ATEX
II Signifies suitability for use in surface industries
2 Signifies suitability for use in a zone 1 area
G Signifies suitability for use in the presence of gases
6
Loudspeaker - DB4B
English
Gas & dust (GD) certified units
Certified to EN60079-0, EN60079-1, EN60079-7 and
EN60079-31
Ex d IIIC unit (ATEX certification No. Baseefa13ATEX0231X)
Ex db IIC T
G
(T
amb.
) Gb
Ex tb IIIC T
D
(T
amb.
) Db IP6X
Ex de IIIC unit (ATEX certification No. Baseefa13ATEX0233X)
Ex db eb IIC T
G
(T
amb.
) Gb
Ex tb IIIC T
D
(T
amb.
) Db IP65/66*
*depending on outer flare type (Short flare IP65, Long
flare – IP66)
See special conditions for safe use for ambient tempera-
ture ranges and T-ratings.
The ATEX certificate and product label carry the ATEX
group and category marking:
II 2 GD
Where:
Signifies compliance with ATEX
II Signifies suitability for use in surface industries
2 Signifies suitability for use in a zone 1 area
G Signifies suitability for use in the presence of gases
D Signifies suitability for use in the presence of dust
These units also have the following approvals:
Ingress protection: Ex d & Ex e terminal chambers - IP66
& IP67 to IEC60529.
DNV Type approved. Approved according to IEC60945:
Maritime navigation and radio communication equipment
and systems.
The equipment is classed as exposed.
Minimum compass safe distance is 5m.
7.0 Special conditions for safe use
a) Type DB4B Ex d:
IECEx BAS 13.0112X, IECEx BAS 13.0113X,
Baseefa13ATEX0229X & Baseefa13ATEX0231X
1. For replacement purposes the cover fixing screws
shall be of stainless steel grade A2-70 or stronger.
2. Painting and surface finishes, other than those applied
by the manufacturer, are not permitted.
3. When the unit is used in dust atmospheres (GD units
only) the cable entries used shall be sealed to main-
tain the IP6X rating, in accordance with the applicable
installation codes.
4. This apparatus is suitable for use only in ambient
temperatures as follows:
Max. Power
rating
T
amb.
T
G
T
D
8W
-5C to +8C T4 T135°C
-5C to +55°C T5 T100°C
-5C to +40°C T6 T85°C
15W
-5C to +8C T3 T200°C
-5C to +70°C T4 T135°C
-5C to +40°C T5 T100°C
25W
-5C to +70°C T4 T135°C
-5C to +40°C T5 T100°C
b) Type DB4B Ex de:
IECEx BAS 13.0114X, IECEx BAS 13.0115X,
Baseefa13ATEX0232X & Baseefa13ATEX0233X
1. For replacement purposes the cover fixing screws
shall be of stainless steel grade A2-70 or stronger.
2. Painting and surface finishes, other than those applied
by the manufacturer, are not permitted.
3. Not more than one single or multiple strand wiring
lead shall be connected into either side of any
terminal, unless multiple conductors have been joined
in a suitable manner, e.g. two conductors into a single
insulated boot lace ferrule.
4. Leads connected to the terminals shall be insulated for
at least 275V and this insulation shall extend to within
1mm of the metal of the terminal throat.
5. Minimum creepage and clearance distances between
the terminals and adjacent conductive parts (including
cable entry devices) must be at least 6mm.
6. All terminal screws, used and unused, shall be
tightened down.
7. When the unit is used in dust atmospheres (GD
units only) the cable entries used shall be sealed
to maintain the IP6X rating, in accordance with the
applicable installation codes.
8. If used, internal optional earthing material shall be
anti-corrosive.
9. This apparatus is suitable for use only in ambient
temperatures as follows:
Max. Power
rating
T
amb.
T
G
T
D
8W
-50°C to +85°C T4 T135°C
-50°C to +5C T5 T100°C
-50°C to +4C T6 T85°C
15W
-50°C to +85°C T3 T200°C
-50°C to +70°C T4 T135°C
-50°C to +4C T5 T100°C
25W
-50°C to +70°C T4 T135°C
-50°C to +4C T5 T100°C
LOUDSPEAKER - DB4B TM252 Issue D August 2018 www.eaton.com
7
Loudspeaker - DB4B
English
8.0 Functional safety
Introduction
The DB4B Loudspeaker has been designed for use in
potentially explosive atmospheres and harsh environmen-
tal conditions. The glass reinforced polyester enclosures
are suitable for use offshore or onshore, where light
weight combined with corrosion resistance is required.
The safety function of the Speaker is to provide an audible
warning when required.
Under No fault (Normal) Operating conditions the DB4B
Speaker will provide an audible warning sound when
required by the system.
Under fault conditions the failure mode of the Speaker
is a failure to provide an audible warning sound. For the
failure rate associated with this failure mode please refer
to the table below.
Assessment of Functional Safety
This Loudspeaker is intended for use in a safety system
conforming to the requirements of IEC61508.
UL has conducted a Failure Modes Effect and Diagnostic
Analysis (FMEDA) of the DB4B Loudspeaker against the
requirements of IEC 61508-2 using a Proof Test Interval
of 8760hrs.
The results are shown below and are based on Route 1
H
.
The Speaker is classed as a Type A device.
DB4B Speaker
Safety Function of the DB4B Speaker:
‘To raise an audible warning sound when required
Architectural constraints: Type A
HFT=0
SFF= 71.5%
Proof Test Interval
=8760Hrs
MTTR = 8 Hrs
SIL2
Random hardware failures: λ
DD
= 0
λ
DU
= 2.88E-08
λ
SD
= 0
λ
SU
= 7.22E-08
Probability of failure on demand: PFD
AVG
=1.26E-04
(Low Demand Mode)
SIL3
Probability of Dangerous failure on
safety function:
PFH = 2.88E-08
(High Demand Mode)
SIL3
Hardware safety integrity
compliance
[1]
Route 1
H
Systematic safety integrity
compliance
Route 1
S
Systematic Capability SC2
Overall SIL-capability achieved SIL 2 (Low Demand)*
SIL 2 (High Demand)*
*Limited to SIL 2 due to SFF value
LOUDSPEAKER - DB4B TM252 Issue D August 2018 www.eaton.com
8 LOUDSPEAKER - DB4B TM252 Issue D May 2019 www.eaton.com
Loudspeaker - DB4B
English
8
Conditions of safe use
The following conditions apply to the installation, operation and maintenance of the assessed equipment. Failure to
observe these may compromise the safety integrity of the assessed equipment:
1. The user shall comply with the requirements given in the manufacturers user documentation (This Safety Manual and
Technical manual) in regard to all relevant functional safety aspects such as application of use, installation, operation,
maintenance, proof tests, maximum ratings, environmental conditions, repair, etc;
2. Selection of this equipment for use in safety functions and the installation, configuration, overall validation,
maintenance and repair shall only be carried out by competent personnel, observing all the manufacturer’s conditions
and recommendations in the user documentation.
3. All information associated with any field failures of this product should be collected under a dependability
management process (e.g., IEC 60300-3-2) and reported to the manufacturer.
4. The unit should be tested at regular intervals to identify any malfunctions; in accordance with this safety manual
5. If the product is used in a redundant installation, both hardware safety integrity and systematic safety integrity for
SIL 2 can be achieved. The installation must be such as to ensure sufficient protection against common cause failures
and independence from cascading failures..
9
Loudspeaker - DB4B
Francais
Contents
1.0 INTRODUCTION ....................... 10
2.0 MESSAGES ET AVERTISSEMENTS GÉNÉRAUX DE SÉCURITÉ .......10
3.0 INSTALLATION ......................................................................11
Accès aux bornes ...........................................................................11
Détail du câblage
............................................................................11
4.0 FONCTIONNEMENT .................................................................12
5.0 ENTRETIEN ........................................................................13
6.0 CERTIFICATION/APPROBATIONS ......................................................14
Unités IECEx .............................................................................. 14
Unités certifiées pour les gaz (G)
.............................................................. 14
Unités certifiées pour gaz et poussière (GD)
..................................................... 14
Unités ATEX
............................................................................... 14
Unités certifiées pour les gaz (G)
.............................................................. 14
Unités certifiées pour gaz et poussière (GD)
..................................................... 15
Ces unités bénéficient également des approbations suivantes :
...................................... 15
7.0 CONDITIONS SPÉCIALES POUR UTILISATION SÉCURISÉE .................................15
8.0 SÉCURITÉ FONCTIONNELLE ..........................................................16
Introduction ............................................................................... 16
Conditions d’utilisation sécurisée
.............................................................. 17
LOUDSPEAKER - DB4B TM252 Issue D August 2018 www.eaton.com
10
Loudspeaker - DB4B
Francais
LOUDSPEAKER - DB4B TM252 Issue D May 2019 www.eaton.com
1.0 Introduction
Cette gamme de haut-parleurs, conçue pour être utilisée
dans des atmosphères gazeuses potentiellement explo-
sives et poussiéreuses, a une puissance nominale jusqu’à
25 Watt et est disponible dans des versions adaptées aux
groupes de gaz et/ou de poussières suivants:
La gamme est disponible dans des versions adaptées
pour une utilisation soit avec des groupes de gaz (G), soit
avec des groupes de gaz et poussières (GD).
ote:N l’unité (G) a une puissance de sortie nominale
supérieure de 6 dB à celle d’une unité (GD)
Le boîtier Ex est fabriqué en polyester renforcé de fibres
de verre résistant aux UV et ayant une robuste balise
thermoplastique. L’intégration d’un support en acier
inoxydable, des vis du couvercle et des fixations garantit
un produit anticorrosion.
Une boîte de raccordement Exe en option est disponible
(voir la section de certification pour plus de détails).
Une version non certifiée est disponible pour une utilisation
dans des atmosphères non explosives.
2.0 Messages et avertissements
généraux de sécurité
Suivre toutes les instructions et messages de sécurité
contenus dans ce manuel pour permettre l’installation
sécurisée de l’appareil. L’appareil doit être exclusivement
installé et entretenu par du personnel/des installateurs sur
site correctement formés.
I. Pour réduire le risque d’incendie dans des
atmosphères dangereuses et de décharges, ne pas
mettre l’appareil sous tension avant d’avoir terminé
l’installation et avant de l’avoir parfaitement scellé et
sécurisé.
II. Pour réduire le risque d’incendie dans des
atmosphères dangereuses et de décharges, maintenir
l’appareil totalement fermé lors de la mise sous
tension du circuit.
III. Avant de retirer le couvercle pour toute opération
d’installation ou d’entretien, s’assurer que
l’alimentation de l’appareil est isolée.
IV. Une fois l’installation terminée, tester l’appareil pour
s’assurer de son bon fonctionnement.
V. Une fois l’installation terminée, s’assurer qu’une copie
de ce manuel est mise à la disposition de tous les
opérateurs.
VI. Lors de l’installation de l’appareil, se reporter
aux exigences de sélection, d’installation et de
fonctionnement : par exemple les Réglementations
de câblage de l’IEE et le Code national d’électricité
américain (NEC) pour l’Amérique du Nord. Des
exigences nationales et/ou locales supplémentaires
peuvent également s’appliquer.
VII. Les terminaisons de câble doivent être conformes aux
exigences spécifiques de l’application requise. MEDC
recommande que tous les câbles et conducteurs soient
correctement identifiés. Merci de se reporter au schéma
de câblage fourni dans ce manuel (ou au schéma
spécifique fourni avec l’unité).
VIII. S’assurer de n’utiliser que les presse-étoupe
spécifiés ou certifiés et vérifier que l’ensemble soit
bien protégé et mis à la terre.
IX. S’assurer de n’utiliser que les bouchons obturateurs
spécifiés ou certifiés pour obturer les entrées de
presseétoupe non utilisées et vérifier que le degré de
protection NEMA/IP de l’unité soit maintenu.
X. MEDC recommande l’utilisation d’une pâte
d’étanchéité telle que HYLOMAR PL32 sur tous
les filetages des presse-étoupe et des bouchons
obturateurs et /ou d’une rondelle d’étanchéité
adaptée, afin de maintenir le degré de protection IP
de l’unité.
XI. Sur les unités Ex de, une rondelle d’étanchéité
adaptée doit être montée sur tous les presse-étoupe
et les bouchons obturateurs présents dans le boîtier
Ex e.
XII. L’utilisateur nal ou l’installateur doit s’assurer que
cet équipement est protégé contre les inuences
extérieures qui pourraient nuire à la protection contre
les explosions, ou contacter le fabricant en cas de
doute sur son adéquation à l’environnement dans
lequel il doit être installé.
XIII. Unités Ex d
La borne de terre interne doit être utilisée pour une
mise à la terre de protection lorsque nécessaire. Ne pas
retirer la tresse de masse de la borne de terre.
Pour les unités avec entrées métriques ; la continuité du
presse-étoupe et la mise à la terre peuvent être réalisés
avec une plaque de masse externe en option. Si la plaque
externe est montée, un composé d’étanchéité de filetage
comme HYLOMAR PL32 doit être employé pour maintenir
la classification IP de l’appareil.
Une tige interne supplémentaire est fournie pour une
connexion de terre sans bruit (propre)
là où les codes
locaux ou les autorités autorisent ou requièrent une telle
connexion.
Unités Ex d e
La tige de mise à la terre interne/externe doit être utilisée
pour la mise à la terre de l’équipement au besoin. La
continuité du presse-étoupe est réalisée si la plaque de
mise à la terre interne en option est installée.
XIV. MEDC recommande l’utilisation d’éléments de
fixation en acier inoxydable lors de l’installation de
l’appareil. S’assurer que tous les écrous, les boulons
et les fixations sont sécurisés.
XV. L’unité doit être positionnée de façon que les débris,
la poussière ou l’eau ne puissent pas pénétrer dans
le pavillon.
XVI. L’unité doit être placée de telle sorte que tout objet
solide ne faisant pas partie de l’équipement, se
trouve à un minimum de 40 mm du joint Ex d situé
sur le parcours des flammes.
XVII.L’acheteur doit informer le fabricant de tout impact
externe ou de toute substance agressiveauxquels
l’appareil peut être exposé
11
Loudspeaker - DB4B
Francais
LOUDSPEAKER - DB4B TM252 Issue D May 2019 www.eaton.com
3.0 Installation
L’unité est montée à l’aide de 2 trous de fixation de 9 mm
de diamètre sur l’étrier et/ou support en forme de U. Si
nécessaire, l’unité peut être mise en place au départ à
l’aide du trou central de 13 mm de diamètre prévu dans
l’étrier. L’unité peut ensuite être tournée en position
requise et fixée à l’aide des autres trous.
Si elle est commandée avec l’unité, une option comportant
un étrier de montage pivotant est disponible pour permettre
un réglage supplémentaire en rotation de l’unité.
Les trous de fixation ont été conçus pour accueillir une vis
ou un boulon M8.
Accès aux bornes
Sur les versions Ex d, le couvercle est fixé à l’aide de
6vis imperdables M5 (à l’aide d’une clé hexagonale/à
6pans de 4 mm). Une fois que les fixations du couvercle
sont dévissées, il est possible de démonter le couvercle
en le soulevant pour accéder à l’intérieur. Les fixations du
couvercle sont imperdables et restent liées au couvercle.
Sur les versions Ex de, le couvercle amovible est fixé à l’aide
de 3 vis imperdables M5 (à l’aide d’une clé hexagonale/à 6
pans de 4 mm). Une fois que les fixations du couvercle sont
dévissées, il est possible de démonter le couvercle en le
soulevant pour accéder à l’intérieur. Les fixations du couvercle
sont imperdables et restent liées au couvercle. Toutes les vis
des bornes, utilisées ou non, doivent être serrées à fond.
Une fois l’opération de terminaison des câbles achevée,
remettre le couvercle en place sur le corps en faisant
attention à ne pas endommager les surfaces de contact.
Serrer uniformément les vis du couvercle. Sur les
versions Ex de certifiées, s’assurer que le couple maximal
est bien appliqué aux vis du couvercle, comme indiqué
sur le couvercle Ex e. S’assurer que le joint torique est
correctement fixé sur le couvercle pendant le remontage.
Sur les versions Ex d certifiées, s’assurer que la distance
maximale nécessaire de 0,04 mm est bien maintenue
entre le couvercle et la base après l’assemblage.
Détail du câblage
Câblage standard DB4B Câblage Ex de standard DB4B
Pour les unités standard, brancher les connexions électriques aux bornes numérotées afin d’obtenir la dérivation
électrique nécessaire (voir la section 4 pour
le tableau des dérivations). Pour les connexions des boucles de sortie, utiliser le deuxième ensemble de bornes
numérotées.
Câblage Ex d 8 Ohms DB4B Câblage Ex de 8 Ohms DB4B
Pour les unité à connexion directe de 8 Ohms, brancher l’alimentation de l’amplificateur aux bornes comme indiqué en
détail, en annotant la puissance nominale maximale du haut-parleur. Pour les connexions de sortie, utiliser le deuxième
couple de bornes numérotées, si nécessaire.
12
Loudspeaker - DB4B
Francais
LOUDSPEAKER - DB4B TM252 Issue D May 2019 www.eaton.com
blage Ex d DB4B avec coiffe ET/OU PPTC en option Câblage Ex de DB4B avec coiffe ET/OU PPTC en option
Unités Ex d :
Connecter les raccordements à la ligne de 100V aux bornes
marquées « line » sur la carte de circuit imprimée pour la
boucle de sortie, le cas échéant. Utiliser le câble volant avec
les connexions de boucle d’entrée et de sortie communes
pour choisir le niveau de puissance nécessaire (voir section 4
pour le tableau des dérivations)
Unités Ex de :
Connecter les raccordements à la ligne de 100V aux bornes
1 et 2 (boucle d’entrée, boucle de sortie). Si la fonctionnalité
boucle entrée, boucle de sortie est nécessaire, les deux
conducteurs doivent être reliés ensemble dans un seul
embout d’extrémité lié et serti. Utiliser le câble volant
fourni avec le conducteur commun pour choisir le niveau
de puissance nécessaire (voir section 4 pour le tableau
des dérivations)
4.0 Fonctionnement
La tension de la ligne et la puissance nominale de l’unité
sont indiquées sur l’étiquette. Le haut-parleur est disponible
en 3 puissances nominales standard de 8 à 25 W et dans les
versions Ex d ou Ex de. Il est possible d’obtenir différents
niveaux sonores en sélectionnant les dérivations du
transformateur dans l’unité. Voir le tableau ci-dessous pour
les détails.
En alternative, sur demande lors de la commande, l’unité
peut être équipée d’une connexion directe de 8 Ohms au
pilote pour le raccordement à une source audio adaptée.
rivations du
transformateur
Puissance (W)
25W 15W 8W
1:2 25.0 15.0 8.0
2:3 12.5 7.5 4.0
3:4 6.0 5.0 2.0
1:3 4.0 4.0 1.5
2:4 2.0 2.0 0.7
1:4 1.0 0.8 0.4
13
Loudspeaker - DB4B
Francais
LOUDSPEAKER - DB4B TM252 Issue D May 2019 www.eaton.com
Disposition générale
5.0 Entretien
L’unité ne devrait nécessiter que peu ou pas d’entretien au cours de sa durée de vie. GRP résiste à l’attaque de la plupart
des acides, des bases et des produits chimiques, ainsi qu’aux acides et produits alcalins concentrés comme la plupart
des produits métalliques.
Cependant, dans l’éventualité de conditions environnementales anormales ou inhabituelles dues à des dommages subis
en usine ou à un accident, etc., une inspection visuelle est recommandée.
Voir le schéma ci-dessous pour le détail des raccords antidéflagrants placés dans l’appareil. AVERTISSEMENT ! – Les
raccords antidéflagrants détaillés ci-dessous ne sont pas destinés à être réparés.
TRAJECTOIRE DE
FLAMME - TROUS POUR
VIS INTÉRIEURES
MINIMUM 9,5
CACHE/BOÎTIER Ex d
TRAJECTOIRE DE FLAMME
ENTRÉE DE PRESSE- ÉTOUPE -
ÉPAISSEUR DU MUR MINIMUM 18
2 POSITIONS MAX.
DÉTAIL DE L’ENTRÉE
DES CÂBLES
14 LOUDSPEAKER - DB4B TM252 Issue D May 2019 www.eaton.com
Loudspeaker - DB4B
Francais
Si l’unité doit être nettoyée, ne nettoyer que l’extérieur
avec un chiffon humide pour éviter l’accumulation d’une
charge électrostatique.
Dans l’éventualité d’une défaillance de l’unité, MEDC peut
la réparer.
En cas d’acquisition d’un nombre important d’unités, il est
recommandé de prévoir également des pièces détachées.
Merci de discuter de vos besoins spécifiques avec les
ingénieurs technico-commerciaux de MEDC.
RÉF. Description N° Composant
10 Vis de couvercle Ex d (x 6 requises) PX99901028
20 Couvercle Ex d (joint et vis inclus) PX99902304
30 Pavillon principal (version longue, joint et vis inclus)* Contacter MEDC*
40 Vis de pavillon principal (x 4 requises) PX99902305
50 Joint de pavillon principal (requis uniquement pour un pavillon long) PX99902306
60 Étrier Contacter MEDC
70 Trousse de fixation de l’étrier PX99902307
80 Pavillon principal (version courte, joint et vis inclus)* Contacter MEDC*
90 Couvercle Ex de (joint inclus) PX99902308
100 Vis de couvercle Ex de (x 3 requises) PX99901028
* Remarque : pour les articles 30 et 80, n’oubliez pas de préciser à MEDC le(s) numéro(s) de série des appareils à titre de référence.
6.0 Certification/approbations
Unités IECEx
Unités certifiées pour les gaz (G)
Certification selon les normes IEC60079-0, IEC60079-1 et
IEC60079-7
Unité Ex d IIC (Certification IEC n° IECEx BAS 13.0112X)
Ex db IIC T
G
(T
amb.
) Gb
Unité Ex de IIC (Certification IEC n° IECEx BAS 13.0114X)
Ex db eb IIC T
G
(T
amb.
) Gb
Voir les conditions spéciales pour une utilisation sûre en
fonction des gammes de températures ambiantes et des
températures nominales.
Le certificat et l’étiquette du produit IECEx portent la
marque IECEx du niveau de protection de l’équipement :
Gb
Où Gb signifie adaptation à l’utilisation dans la zone
industrielle de surface en Zone 1 en présence de gaz.
Unités certifiées pour gaz et poussière (GD)
Certification selon les normes IEC60079-0, IEC60079-1,
IEC60079-7 et IEC60079-31
Unité Ex d IIIC (Certification IEC n° IECEx BAS 13.0113X)
Ex db IIC T
G
(T
amb.
) Gb
Ex tb IIIC T
D
(T
amb.
) Db IP6X
Unité Ex de IIIC (Certification IEC n° IECEx BAS 13.0115X)
Ex db eb IIC T
G
(T
amb.
) Gb
Ex tb IIIC T
D
(T
amb.
) Db IP65/66*
* selon le type de cone extérieure ( pavillon courte - IP65,
pavillon longue - IP66 )
Voir les conditions spéciales pour une utilisation sûre en
fonction des gammes de températures ambiantes et des
températures nominales.
Le certificat et l’étiquette du produit IECEx portent la
marque IECEx du niveau de protection de l’équipement.
Gb et Db
Gb signifie adaptation à l’utilisation dans la zone
industrielle de surface en Zone 1 en présence de gaz.
Db signifie adaptation à l’utilisation dans la zone
industrielle de surface en Zone 21 en présence
de poussière.
Unités ATEX
Unités certifiées pour les gaz (G)
Certification selon les normes EN60079-0, EN60079-1 et
EN60079-7
Unité Ex d IIC (certification ATEX n° Baseefa13ATEX0229X)
Ex db IIC T
G
(T
amb.
) Gb
Unité Ex de IIC
(certification ATEX n° Baseefa13ATEX0232X)
Ex db eb IIC T
G
(T
amb.
) Gb
Voir les conditions spéciales pour une utilisation sûre en
fonction des gammes de températures ambiantes et des
températures nominales.
Le certificat et l’étiquette du produit ATEX portent le
marquage du groupe et de la catégorie ATEX :
II 2 G
Où:
signifie conformité ATEX
II signifie adaptation à l’utilisation dans les industries en
surface
2 signifie adaptation à l’utilisation en Zone 1
G signifie adaptation à l’utilisation en présence de gaz
15LOUDSPEAKER - DB4B TM252 Issue D May 2019 www.eaton.com
Loudspeaker - DB4B
Francais
Unités certifiées pour gaz et poussière (GD)
Certification selon les normes EN60079-0, EN60079-1,
EN60079-7 et EN60079-31
Unité Ex d IIIC (certification ATEX n° Baseefa13ATEX0231X)
Ex db IIC T
G
(T
amb.
) Gb
Ex tb IIIC T
D
(T
amb.
) Db IP6X
Unité Ex de IIIC (certification ATEX n° Baseefa13ATEX0233X)
Ex db eb IIC T
G
(T
amb.
) Gb
Ex tb IIIC T
D
(T
amb.
) Db IP65/66*
* selon le type de cone extérieure ( pavillon courte - IP65,
pavillon longue - IP66 )
Voir les conditions spéciales pour une utilisation sûre en
fonction des gammes de températures ambiantes et des
températures nominales.
Le certificat et l’étiquette du produit ATEX portent le
marquage du groupe et de la catégorie ATEX :
II 2 GD
Où:
signifie conformité ATEX
II signifie adaptation à l’utilisation dans les industries
en surface
2 signifie l’adaptation à l’utilisation en Zone 1
G signifie adaptation à l’utilisation en présence de gaz
D signifie adaptation à l’utilisation en présence
de poussière
Ces unités bénéficient également des
approbations suivantes :
Norme sur l’homologation : boîtes de raccordement Ex d
et Ex e - IP66 et IP67 selon la norme IEC 60529.
Homologation de type DNV. Certifié conforme à la norme
IEC 60945 : équipement et systèmes de navigation et de
radiocommunication maritimes.
L’équipement appartient à la catégorie des matériels exposés.
La distance minimale de sécurité du compas est de 5 m.
7.0 Conditions spéciales pour utilisation
sécurisée
a) Ex d type DB4B :
IECEx BAS 13.0112X, IECEx BAS 13.0113X,
Baseefa13ATEX0229X et Baseefa13ATEX0231X
1. Lors des remplacements nécessaires, utiliser des vis
de fixation en acier inoxydable type A2-70 ou plus
résistant pour le couvercle.
2. Les peintures et les finitions des surfaces, autres que
celles du fabricant, ne sont pas autorisées.
3. Lorsque l’unité est utilisée dans des atmosphères
poussiéreuses (unités GD uniquement), les entrées
de câble doivent être étanchéifiées pour garantir
l’homologation IP6X, conformément aux codes et aux
normes d’installation applicables.
4. Cet appareil ne doit être utilisé qu’aux températures
ambiantes de la façon suivante:
À puissance
maximale
T
amb.
T
G
T
D
8W
-5C à +85°C T4 T135°C
-5C à +5C T5 T100°C
-5C à +4C T6 T85°C
15W
-5C à +85°C T3 T200°C
-5C à +70°C T4 T135°C
-5C à +4C T5 T100°C
25W
-5C à +70°C T4 T135°C
-5C à +4C T5 T100°C
b) Ex de type DB4B :
IECEx BAS 13.0114X, IECEx BAS 13.0115X,
Baseefa13ATEX0232X et Baseefa13ATEX0233X
1. Lors des remplacements nécessaires, utiliser des vis
de fixation en acier inoxydable type A2-70 ou plu résis-
tant pour le couvercle.
2. Les peintures et les finitions des surfaces, autres que
celles du fabricant, ne sont pas autorisées.
3. Pas plus d’un câble à un seul brin ou à plusieurs brins
ne doit être raccordé à l’une ou l’autre des extrémités
des bornes, à moins que de multiples conducteurs
ne soient reliés de façon appropriée, par ex. deux
conducteurs dans un seul embout d’extrémité lié
et isolé.
4. Les câbles raccordés aux bornes doivent être isolés
pour une tension d’au moins 275 V et cette isolation
doit être étendue à 1 mm du métal du col de la borne.
5. Les lignes de fuite et les distances d’isolement
minimales entre les bornes et les éléments conducteurs
adjacents (y compris les dispositifs d’entrée de câbles)
doivent être d’au moins 6 mm.
6. Toutes les vis des bornes, utilisées ou non, doivent
être serrées à fond.
7. Lorsque l’unité est utilisée dans des atmosphères
poussiéreuses (unités GD uniquement), les entrées
de câble doivent être étanchéifiées pour garantir
l’homologation IP6X, conformément aux codes et aux
normes d’installation applicables.
8. S’il est utilisé, le matériau de mise à la terre en option
interne doit être anticorrosif.
9. Cet appareil ne doit être utilisé qu’aux températures
ambiantes de la façon suivante:
À puissance
maximale
T
amb.
T
G
T
D
8W
-50°C à +8C T4 T135°C
-50°C à +55°C T5 T100°C
-50°C à +40°C T6 T85°C
15W
-50°C à +8C T3 T200°C
-50°C à +70°C T4 T135°C
-50°C à +40°C T5 T100°C
25W
-50°C à +70°C T4 T135°C
-50°C à +40°C T5 T100°C
16 LOUDSPEAKER - DB4B TM252 Issue D May 2019 www.eaton.com
Loudspeaker - DB4B
Francais
16
8.0 Sécurité fonctionnelle
Introduction
Le haut-parleur DB4B a été conçu pour être utilisé dans
des atmosphères potentiellement explosives et des
conditions environnementales sévères. Les boîtiers en
polyester renforcé de fibres de verre sont adaptés à une
utilisation off-shore ou on-shore, où un poids léger et un
haut niveau de résistance à la corrosion sont nécessaires.
La fonction de sécurité du diffuseur sonore est de fournir
un avertissement sonore lorsque nécessaire.
Dans des conditions de fonctionnement sans
défaillance (normales), le haut-parleur DB4B émet un
avertissement sonore sur demande du système.
En cas de panne/défaillance, le mode de panne du
haut-parleur est indiqué par l’échec de l’émission de
l’avertissement sonore. Pour de plus amples détails sur le
taux d’échec/défaillance associé à ce mode de panne, voir
le tableau ci-dessous.
Évaluation de sécurité fonctionnelle.
Ce haut-parleur est destiné à être utilisé dans un système
de sécurité conforme aux exigences IEC61508.
UL a procédé à une étude «Effet des modes de panne
et analyse du diagnostic» (Failure Modes Effect and
Diagnostic Analysis: FMEDA) sur le haut-parleur DB4B
par rapport aux exigences IEC 61508-2, avec un intervalle
entre essais de sûreté de 8760 heures.
Les résultats sont présentés ci-dessous et sont basés sur
la Route 1
H
.
Le haut-parleur a été classé comme appareil de type A.
Haut-parleur DB4B
Fonction de sécurité du diffuseur sonore DB4B:
« Émettre un avertissement sonore lorsque nécessaire »
Contraintes architecturales: Type A
HFT = 0
SFF = 71,5 %
Intervalle entre essais de
sûreté
= 8 760 heures
MTTR (moyenne des temps
techniques de réparation) =
8 heures
SIL2
Défaillances de matériel aléatoires: λ
DD
= 0
λ
DU
= 2,88E-08
λ
SD
= 0
λ
SU
= 7,22E- 0 8
Probabilité de défaillance sur
demande:
PFD
AVG
=1,26E-04
(mode demande faible)
SIL3
Probabilité de défaillance dangereuse
sur
fonction de sécurité:
PFH = 2,88E-08
(mode demande élevée)
SIL3
Conformité d’intégrité de sécurité du
matériel
[1]
Route 1
H
Conformité d’intégrité de sécurité
systématique
Route 1
S
Capacité systématique SC2
Capacité SIL globale atteinte SIL 2 (demande faible)*
SIL 2 (demande élevée)*
*Limitée à SIL 2 en raison de la valeur SFF
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

MEDC DB4B Le manuel du propriétaire

Catégorie
Haut-parleurs de la barre de son
Taper
Le manuel du propriétaire