Greenlee 600LS Test Set Manuel utilisateur

Catégorie
Testeurs de réseau câblé
Taper
Manuel utilisateur
Introduction
This manual is intended to familiarize users with the safe
operation and maintenance procedures for the Model
600LS Test Set.
Please read this entire manual before operating the tool
and keep this manual available to all personnel.
Replacement manuals are available upon request at no
extra charge.
Safety
Safety is essential in the use and maintenance of Tempo
tools and equipment. This instruction manual and any
markings on the tool provide information for avoiding
hazards and unsafe practices related to the use of this tool.
Observe all of the safety information provided.
Description
The 600LS test set is housed in a grey and blue plastic
case. Red and black test leads are provided, which are
equipped with alligator clips and are permanently attached
to the set.A four conductor modular plug and cord, plus two
light emitting diodes (LEDs), provide a modular polarity
test. A six position slide switch controls the modes of
operation, and there is a three position slide switch for
testing each line at the modular plug.
The tone, level, resistance and capacitance features are
powered by one internal 9 volt battery. The addition of a
second 9 volt battery increases talk battery supply over
original designs. (See Fig. 13) The polarity test feature is
line powered.
The 600LS test set provides the following features:
Tone
A two tone audio trace signal is used to identify cable
pairs, drop wires and I/O wire pairs and for proving
continuity of single conductors.The signal will also radiate
with sufficient strength to be detected by a lineman's test
set or an inductive amplifier.
Level
This position is for checking line condition. No tone
indicates a dead line or reversed polarity (0V-2V). An
alternating (Hi-lo) tone indicates an active line off-hook
(2V-28V).A steady tone indicates an active line not in use
(28V-48V).
Battery
Approximately 18 volts of talk battery is provided for two
way communication, when two batteries are installed.
Resistance
This feature provides an audible indication of various
levels of circuit and insulation resistance. With the test
leads connected to a low resistance circuit, a rapid series
of beeps is produced by the test set. As the resistance of
the circuit being tested increases, the time interval
between beeps also increases.
Capacitance
An audible indication of circuit capacitance is produced by
the internal speaker.This test can be used to indicate the
amount of capacitance on a line.
PolarityTest - Two 2-color LEDs provide visible
indication of central office battery polarity present at a
modular connector. Ringing current is indicated by a
red/green flickering LED (appears yellow). (See Polarity
Testing)
Modular Test Selector Switch - The above tests,
except polarity, may be performed on Line 1 or Line 2
through the modular cord. (See Modular Line Testing)
Calibration
In resistance mode, an internal resistor valued at 1meg
ohm is provided for comparison to the fault resistance of
the circuit or facility being tested.
Operation
All tests and operations outlined in the following paragraphs
are to be conducted with central office battery and any other
source of electrical current disconnected from the facilities
under test.This does not apply to level and line polarity tests.
Battery Check and Operational Test
To perform a battery check and operation test, place the
slide switch in the “capacitance” position. An audio tone
should be heard at the speaker opening indicating a good
battery. If the audio tone is not heard, short the test leads
together and place the slide switch in the “resistance”
position.This should produce a rapid series of beeps from
the speaker. If no beeps are heard, replace the batteries
as outlined in the Maintenance Section and repeat.
A test set which fails to operate in any one of the modes
after a new battery has been installed should be replaced.
Calibration
With the slide switch
in the “resistance”
position, touch the clip
of the red test lead to
the top plate or screw
head next to the slide
switch opening. This
places a 1 megohm
resistance on the test
set leads through an
internal resistor. The
set should then
produce a series of
beeps approximately one per second.This beep rate will
subsequently be referred to as the “calibration rate. This
rate will vary between test sets due to the component
differences and battery condition. (See Fig. 2)
A circuit can be considered to be clear of insulation faults
if when tested with the resistance feature of the 600LS test
set, it produces a series of beeps at a rate equal to or
slower than the beep rate of 1 beep every 4 seconds,
approximately 4 megohms.
Tone Operation
The “tone” position is used to identify pairs of conductors
and to prove continuity. The dual tone trace signal is
detected with a standard telephone set or a lineman's test
set with the talk-monitor switch in the monitor position.
(See Fig. 3)
Pair identification
can be determined
as follows: Before an
attempt is made to
identify a pair of
conductors, the pair
should first be tested
for shorts and
grounds. Either of
these conditions will
attenuate (lower) the
signal and produce
false indications.
Proceed as outlined
in the Capacitance
Section to ensure
that the pair is “clear”.
After the pair has been “cleared”, place the slide switch in
the “tone” position and connect the test leads to one end
of the line under test and a lineman's test set to the other
end of the line under test. A pair with an “open” conductor
will produce a low tone similar to a “split” pair.
Proving Continuity
To prove continuity of a
single conductor, proceed
as follows: Place slide switch
on the 600LS test set in the
“tone” position.Connect one
test lead from the 600LS test
set to one lead of the
lineman's test set to provide
a “series” connection.
Connect the remaining test
lead from the 600LS to one
end of the conductor being
tested. Use the remaining
lead on the lineman's test set as a “probe” and touch it to
the other end of the conductor while listening for the tone
to be produced in the receiver of the lineman's test set.
(See Fig. 4)
Continuity can also be
proven by using the
“resistance” feature of the
600LS test set.This is done
by proving a relative lack of
resistance in the conductor
being tested.To do so, place
the slide switch in the
“resistance” position and
connect one test lead to one
end of the conduct or to be
tested. (See Fig. 5)
Connect the remaining test
lead to a good conductor
which has been strapped to
Fig. 2
Fig. 3
Fig. 5
Fig. 4
Read and understand this material
before operating or servicing this
equipment. Failure to understand
how to safely operate this tool can
result in an accident causing serious
injury or death.
INSTRUCTION MANUAL
95E0038 Rev. A
MODEL 600LS TEST SET
WARNING
SAFETY
ALERT
SYMBOL
This symbol is used to call your attention to hazards
or unsafe practices which could result in an injury or
property damage. The signal word, defined below,
indicates the severity of the hazard. The message
after the signal word provides information for
preventing or avoiding the hazard.
Immediate hazards which, if not avoided, WILL result
in severe injury or death.
Hazards which, if not avoided, COULD result in
severe injury or death.
Hazards which, if not avoided, MAY result in injury.
DANGER
WARNING
CAUTION
Do not expose this unit to rain or moisture.
Contact with live circuits can result in severe
injury or death.
Use this unit for the manufacturer’s intended
purpose only, as described in this manual. Any
other use can impair the protection provided by
the unit.
Use test leads or accessories that are
appropriate for the application. See the category
and voltage rating of the test lead or accessory.
Inspect the test leads or accessory before use.
The item(s) must be clean and dry, and the
insulation must be in good condition.
Before opening the case, remove the test leads
from the circuit and shut off the unit.
Failure to observe these precautions may result in
severe injury or death.
Do not attempt to repair this unit. It contains no
user-serviceable parts.
Do not expose the unit to extreme temperatures
or high humidity. See Specifications.
Failure to observe these precautions can result in
injury and can damage the instrument.
WARNING
CAUTION
ELECTRIC
SHOCK HAZARD
Introduction
Ce manuel est conçu pour que les utilisateurs puissent se
familiariser avec le fonctionnement et les procédures
d'entretien sécuritaires de l'appareil de vérification modèle
600LS.
Veuillez lire ce manuel intégralement avant d'utiliser l'appareil.
Gardez-le à la disposition du personnel. Des manuels de
remplacement sont disponibles gratuitement sur simple
demande.
Sécurité
La sécurité est essentielle à l'utilisation et l'entretien des outils
et équipements Tempo. Ce manuel d'instructions et les
étiquettes apposées sur l'outil fournissent des informations
permettant d'éviter des dangers ou des manipulations
dangereuses liées à l'utilisation de cet outil. Veuillez suivre
toutes les consignes de sécurité indiquées.
Description
L'appareil de vérification 600LS est logé dans un boîtier gris et
bleu en plastique. Des fils de test rouge et noir à pinces
crocodile lui sont fixés de façon permanente. Il est doté d'une
fonction de test de polarité des lignes assurée par une fiche
modulaire à 4 conducteurs et un cordon, ainsi que deux diodes
(DEL). Un interrupteur à glissière à six positions permet de
contrôler les différents modes de fonctionnement et un
interrupteur à glissière à trois positions permet de tester
chaque ligne au niveau de la fiche modulaire.
Les fonctions de tonalité, de niveau, de résistance et de
capacité sont alimentées par une batterie interne de 9 volts.
L'ajout d'une seconde batterie de 9 volts permet d'augmenter
l'alimentation de la batterie de conversation par rapport aux
modèles originaux. (Voir fig. 13.) La fonction de test de polarité
est alimentée par la ligne.
L'appareil de vérification 600LS comporte les fonctions
suivantes :
Tonalité
Un signal d'analyse audio à double tonalité permet d'identifier
les paires de câble, les fils d'embranchement, les paires de fils
d'entrée/sortie, et de vérifier la continuité des conducteurs
simples.Le signal est suffisamment puissant pour être détecté
par l'appareil de vérification d'un monteur de ligne ou un
amplificateur inductif.
Niveau
Cette position sert à vérifier l'état de la ligne. L'absence de
tonalité indique une ligne morte ou une polarité inversée (0 V-
2 V) Une tonalité alternative (Hi-Lo) indique une ligne
décrochée active (2 V-28 V) Une tonalité constante indique
une ligne active inutilisée (28 V-48 V).
Batterie
Lorsque deux batteries sont installées, une alimentation
d'environ 18 volts pour batterie de conversation est fournie
pour assurer des communications bidirectionnelles.
Résistance
Cette fonction indique par un signal sonore les différents
niveaux de résistance des circuits et des isolations. Lorsque
les fils d'essai sont branchés à un circuit de faible résistance,
l'appareil de vérification produit une série rapide de signaux
sonores. L'intervalle de temps entre les signaux sonores
augmente à mesure que la résistance du circuit testée est
accrue.
Capacité
Le haut-parleur interne indique par un signal sonore la
capacité du circuit. Ce test peut être utilisé pour indiquer le
niveau de capacité présent sur une ligne.
Test de polarité - Deux DEL à 2 couleurs constituent une
indication visible de la polarité de la batterie centrale présente
au niveau d'un connecteur modulaire. Le courant de sonnerie
est indiqué par une DEL rouge/verte s'illuminant de façon
intermittente (d'apparence jaune). (Voir Test de polarité)
Sélecteur de test modulaire - Les tests ci-dessus, à
l'exception du test de polarité, peuvent être effectués sur la
ligne 1 ou la ligne 2 à l'aide du cordon modulaire.(Voir Test de
ligne modulaire)
Calibration
En mode de résistance, une résistance interne de 1 mégohm
permet d'effectuer une comparaison avec la résistance de
défaut du circuit ou de l'installation testée.
Fonctionnement
Tous les tests et opérations indiqués dans les paragraphes
suivants doivent être effectués après s'être assuré que la
batterie centrale et toute autre source de courant électrique est
déconnectée des installations à tester. Ceci ne s'applique pas
aux tests de polarité de niveau et de ligne.
Vérification de la batterie
et test opérationnel
Pour procéder à une vérification de la batterie et à un test
opérationnel, mettez l'interrupteur à glissière en position «
capacité ».Vous devriez entendre une tonalité à l'ouverture du
haut-parleur, ce qui indique que la batterie est en bon état. Si
vous n'entendez pas de tonalité, court-circuitez les fils de test
et mettez l'interrupteur à glissière en position « résistance ».
Ceci devrait produire une succession rapide de signaux
sonores en provenance du haut-parleur.Si aucun signal n'est
émis, remplacez les batteries tel qu'indiqué à la section
Maintenance puis recommencez.
Si l'appareil de vérification
ne fonctionne pas
correctement dans l'un
des modes après
l'installation d'une batterie
neuve, remplacez-le.
Calibration
L'interrupteur à glissière
étant en position
« résistance », touchez
la plaque supérieure
ou la tête de la vis
avec la pince du fil de
test rouge, près de
l'ouverture de l'interrupteur à glissière. Ceci génère un court-
circuit de 1 mégohm sur les fils de l'appareil de vérification par
l'intermédiaire d'une résistance interne. L'appareil devrait
ensuite émettre une série de signaux sonores à un intervalle
d'environ une seconde.Nous appellerons cette fréquence des
signaux sonores « taux de calibration ». Ce taux varie d'un
appareil de vérification à l'autre à cause des différences de
composant et de l'état de la batterie. (Voir fig. 2.)
On peut considérer qu'un circuit ne comporte aucun défaut
d'isolation si, lorsqu'on le teste à l'aide de la fonction résistance
du 600LS, il émet une série de signaux sonores à une
fréquence égale ou inférieure à 1 signal toutes les 4 secondes,
environ 4 mégohms.
Fonctionnement de la tonalité
La position « tonalité » sert à identifier des paires de
conducteurs et à vérifier la continuité. Le signal d'analyse
à double tonalité
peut être détecté à
l'aide d'un téléphone
standard ou d'un
appareil de vérification
de monteur de ligne
dont le sélecteur de
conversation/écoute
discrète est en position
écoute discrète. (Voir
fig. 3.)
L'identification des
paires peut être
déterminée comme
suit : Avant de tenter
d'identifier une paire
de conducteurs, il faut
la tester pour voir s'il y
a présence de courts-
circuits ou de terre.
Dans un cas comme dans l'autre, le signal sera atténué (plus
faible) et de fausses indications seront produites. Procédez
comme indiqué à la section Capacité afin de vous assurer que
la paire est « claire ».
Cela fait, mettez l'interrupteur à glissière en position « tonalité
» et connectez les fils de test à l'une des extrémités de la ligne
à tester et un appareil de
vérification de monteur de ligne
à l'autre extrémité. Une paire
avec un conducteur « ouvert »
produira une faible tonalité
similaire à celle d'une paire «
divisée ».
Vérification de
continuité
Pour vérifier la continuité d'un
seul conducteur, procédez
comme suit : Mettez
l'interrupteur à glissière de
l'appareil de vérification 600LS
en position « tonalité ».
Connectez un fil de test du
600LS à l'un des fils de l'appareil de vérification de monteur de
ligne afin de constituer une connexion « en série ».Connectez
le fil de test restant du 600LS à l'une des extrémités du
conducteur testé. Utilisez le fil restant de l'appareil de
vérification comme « sonde » et touchez-en l'autre extrémité
du conducteur tout en
écoutant pour voir si une
tonalité est émise dans le
récepteur de l'appareil de
vérification. (Voir fig. 4.)
On peut aussi vérifier la
continuité à l'aide de la
fonction « résistance » de
l'appareil de vérification
600LS. Pour cela, il suffit de
vérifier qu'il y a un manque
relatif de résistance dans le
conducteur testé.Procédez en
mettant l'interrupteur à
glissière en position «
résistance » et connectez un
Fil noir
Fil rouge
Pince touchant
la vis
Interrupteur en
position résistance
Fréquence des
signaux sonores
lente
Fig. 2
Interrupteur en
position tonalité
Fig. 3
Interrupteur en
position résistance
Si
g
naux sonores ra
p
ides
Fig. 5
Interrupteur en
position tonalité
Fig. 4
Veuillez lire et bien comprendre ce
manuel avant d'utiliser cet équipement ou
d'en faire l'entretien. Le fait de ne pas
savoir comment utiliser cet outil de façon
sécuritaire peut entraîner des blessures
graves ou la mort.
MODE D’EMPLOI
95E0038 Rev. A
AVERTISSEMENT
SYMBOLE
D'ALERTE DE
SÉCURITÉ
Ce symbole attire l'attention sur les risques de danger
et de mauvaise utilisation pouvant causer des
blessures ou des dommages matériels. Le mot-
indicateur, défini ci-dessous, indique la sévérité du
danger. Le message qui le suit explique comment
prévenir ou éviter le danger en question.
Dangers immédiats qui, à moins d'être évités,
CAUSERONT CERTAINEMENT des blessures
graves ou la mort.
Dangers qui, à moins d'être évités, PEUVENT
CAUSER des blessures graves ou la mort.
Dangers qui, à moins d'être évités, CAUSERONT
PEUT-ÊTRE des blessures.
DANGER
AVERTISSEMENT
MISE EN GARDE
N’exposez pas cet appareil à la pluie ou à
l’humidité.Tout contact avec des circuits sous
tension peut causer des blessures graves ou la
mort.
Employez cet outil uniquement selon l’usage prévu
par le fabricant tel que décrit dans ce manuel. Toute
autre utilisation peut affaiblir la protection assurée
par l’appareil.
Utilisez des fils d’essai ou accessoires appropriés à
l’application. Voir la catégorie et la tension nominale
des fils d'essai ou accessoires.
Inspectez les fils d'essai ou accessoires avant
utilisation. Les pièces doivent être propres et sèches
et l'isolation en bon état.
•Avant d'ouvrir le boîtier, retirez les fils d'essai du
circuit et éteignez l'appareil.
Le non-respect de ces précautions peut causer des
blessures graves ou la mort.
N'essayez pas de réparer l'appareil. Il ne contient
pas de pièces réparables par l'utilisateur.
N'exposez pas l'appareil à des températures
extrêmes ou à un niveau d'humidité élevé. Voir les
Caractéristiques techniques.
Le non-respect de ces précautions peut entraîner des
blessures ou endommager l'instrument.
AVERTISSEMENT
MISE EN GARDE
RISQUE
D’ÉLECTROCUTION
Introducción
Este manual es para familiarizar al personal con la operación
segura y los procedimientos de mantenimiento de la unidad de
prueba Modelo 600LS.
Por favor lea todo el manual antes de hacer funcionar la
herramienta y manténgalo disponible para todo el personal.
Hay manuales adicionales disponibles sin costo alguno,
cuando los solicite.
Seguridad
La seguridad es esencial en el uso y el mantenimiento de las
herramientas y el equipo de Tempo. Este manual de
instrucciones y las marcas presentes en las herramientas
proporcionan información para evitar peligros y prácticas no
seguras relacionadas con el uso de esta herramienta.Observe
toda la información de seguridad proporcionada.
Descripción
La unidad de prueba 600LS está instalada en una caja de
plástico gris y azul.Se proporcionan conductores de prueba de
color rojo y negro, equipados con pinzas cocodrilo y están
permanentemente fijados a la unidad. Un conector modular de
cuatro conductores con cordón, mas dos diodos emisores de
luz (LED) proporcionan una función de prueba modular de la
polaridad. Un interruptor deslizante de seis posiciones
controla los modos de operación y hay un interruptor
deslizante de tres posiciones para probar cada línea en el
conector modular.
Las características de tono, nivel, resistencia y capacidad
están alimentadas por una batería interna de 9 voltios. La
adición de una segunda batería de 9 voltios aumenta la
alimentación de la batería de habla sobre los diseños
originales. (Consulte la Figura 13) La característica de prueba
de polaridad se alimenta mediante la línea.
La unidad de prueba 600LS proporciona las siguientes
características:
Tono
Se usa una señal de seguimiento de audio de dos tonos para
identificar pares de cables, cables derivados y pares de E/S y
para probar la continuidad de un solo conductor. La señal
también se irradiará con suficiente fuerza para que la detecte
un juego de pruebas o un amplificador inductivo de un
instalador de líneas.
Nivel
Esta posición es para comprobar el estado de la línea.La falta
de tono indica que es una línea muerta o que la polaridad está
invertida (0V-2V).Un tono alternado (alto bajo) indica que hay
una línea activa descolgada (2V-28V). Un tono regular indica
que hay una línea activa fuera de uso (28V-48V).
Batería
Aproximadamente 18 voltios de batería de habla para
comunicaciones de dos vías, cuando se instalan dos baterías.
Resistencia
Esta característica proporciona una indicación audible de
varios niveles de resistencia de circuitos y aislamiento. Con
los conductores de prueba conectados a un circuito de baja
resistencia, la unidad de prueba produce una serie rápida de
zumbidos. A medida que aumenta la resistencia del circuito
que se está probando, el intervalo entre zumbidos también
aumenta.
Capacidad
El altavoz interno produce una indicación audible de la
capacidad del circuito.Se puede usar esta prueba para indicar
la cantidad de capacidad de una línea.
Prueba de polaridad - Dos LED de 2 colores proporcionan
una indicación visible de la polaridad de la batería de la oficina
central presente en un conector modular. Un LED destellante
verde y rojo indica que hay corriente de llamada (aparece de
color amarillo). (Consulte Prueba de la polaridad)
Interruptor selector de prueba modular - Se puede
efectuar las pruebas de más arriba, excepto la de polaridad,
en la Línea 1 o en la Línea 2 mediante el cordón modular.
(Consulte Prueba modular de líneas)
Calibración
En el modo de resistencia, se proporciona una resistencia
interna con un valor de 1 megohmio para efectuar una
comparación de la resistencia de falla del circuito o instalación
que se está probando.
Operación
Todas las pruebas y operaciones descritas en los párrafos
siguientes se deben conducir con la batería de la oficina central y
con todas las demás fuentes de corriente eléctrica desconectadas
de la instalación bajo prueba. Esto no se aplica a las pruebas de
nivel y polaridad de línea.
Comprobación de la batería y prueba
operativa
Para efectuar una comprobación de la batería y una prueba
operativa, coloque el interruptor en la posición de "capacidad"
(capacitance). Se debe oír un tono sonoro en la abertura del
altavoz, esto indica que la batería está en buen estado. Si no
se escucha el tono sonoro, ponga en corto circuito los
conductores juntándolos y coloque el interruptor deslizante
en la posición de "resistencia" (resistance). Esto debe
producir una serie rápida de zumbidos del altavoz. Si no se
escuchan zumbidos, cambie las baterías como se describe en
la sección de mantenimiento y repita.
Se debe reemplazar
una unidad de prueba
que no funcione en
ningún modo después
de que se haya
instalado una batería
nueva.
Calibración
Con el interruptor
deslizante en la
posición "resistencia",
toque con el clip del
conductor de prueba
rojo la placa superior o
la cabeza del tornillo próximo a la abertura del interruptor
deslizante. Esto pone una resistencia de 1 megohmio en los
conductores de la unidad de prueba a través de una
resistencia interna. La unidad debe producir entonces una
serie de zumbidos, aproximadamente uno por segundo. A
esta velocidad de zumbidos se le llamará posteriormente la
“velocidad de calibración. Esta velocidad variará con las
unidades de prueba debido a diferencias en los componentes
y al estado de la batería. (Consulte la Figura 2)
Se puede considerar que un circuito está libre de fallas de
aislamiento si cuando se prueba con la característica de
resistencia de la unidad de prueba 600LS, produce una serie
de zumbidos igual a, o mas lenta que 1 zumbido cada 4
segundos, aproximadamente 4 megohmios.
Operación de tono
Se usa la posición de "tonos" (tone) para identificar pares de
conductores y para
probar continuidad. La
señal de seguimiento
de dos tonos se
detecta mediante un
teléfono estándar o
una unidad de prueba
de instalador de líneas
con el interruptor de
monitoreo de habla en
la posición de
monitoreo. (Consulte
la Figura 3)
Se puede determinar
la identificación de
pares de la siguiente
manera: Antes de
tratar de identificar un
par de conductores, se
debe probar primero el
par para ver si hay cortos circuitos a tierra.Cualquiera de estas
condiciones atenuará (bajará) la señal y producirá
indicaciones falsas. Proceda como se describe en la sección
de capacidad para asegurar que el par esté "despejado".
Después de que se haya "despejado" el par, coloque el
interruptor deslizante en la posición de "tono" (tone) y conecte
el conductor de prueba a un
extremo de la línea bajo
prueba y una unidad de
prueba de instalador de líneas
en el otro extremo de la línea
bajo prueba. Un par con un
conductor "abierto" producirá
un tono grave similar al de un
par "dividido".
Prueba de la
continuidad
Para probar la continuidad de
un solo conductor, haga lo
siguiente: Coloque el
interruptor deslizante de la
unidad de prueba 600LS en la
posición de "tono" (tone).Conecte un conductor de prueba de
la unidad de prueba 600LS a un conductor de la unidad de
prueba de instalador de líneas para proporcionar una
conexión en "serie".Conecte el conductor de prueba restante
del 600LS a un extremo del conductor que se está probando.
Use el conductor restante de
la unidad de prueba de
instalador de líneas como una
"sonda" y toque con ella el
otro extremo del conductor
mientras escucha el tono que
se producirá en el receptor de
la unidad de prueba del
instalador de líneas.
(Consulte la Figura 4)
También se puede probar la
continuidad usando la
característica de "resistencia"
de la unidad de prueba
600LS. Esto se hace
probando una falta relativa de
resistencia en el conductor
Conductor negro
Conductor rojo
Clip tocando el
tornillo
Interruptor en la
posición de
resistencia
Velocidad lenta
de zumbido
Fig. 2
Interruptor en la
posición de tono
Fig. 3
Interruptor en la
posición de resistencia
Zumbidos rápidos
Fig. 5
Interruptor en la
posición de tono
Fig. 4
Lea y entienda este material antes de
operar o dar servicio a este equipo. No
entender cómo operar de manera segura
esta herramienta puede resultar en
accidentes, causando lesiones graves o
muerte.
MANUAL DE INSTRUCCIONES
95E0038 Rev. A
UNIDAD DE PRUEBA MODELO 600LS
ADVERTENCIA
SÍMBOLO DE
ALERTA DE
SEGURIDAD
Este símbolo se utiliza para llamar su atención sobre los
peligros o las prácticas no seguras de trabajo que
podrían resultar en lesiones o daños a la propiedad. La
palabra de aviso, definida a continuación, indica la
gravedad del peligro. El mensaje después de la palabra
de aviso proporciona información para prevenir o evitar
el peligro.
Peligros inmediatos que, si no se evitan,
RESULTARÁN en lesiones graves o muerte.
Peligros que, si no se evitan, PODRÍAN resultar
en lesiones muy graves o muerte.
Peligros que, si no se evitan, PUEDEN resultar en
lesiones.
PELIGRO
ADVERTENCIA
PRECAUCIÓN
•No exponga esta unidad a la lluvia o a la humedad.
El contacto con circuitos vivos puede resultar en
lesiones graves o muerte.
Utilice esta unidad sólo para los fines que ha
destinado el fabricante, como se indica en este
manual. Cualquier otro uso puede afectar la
protección proporcionada por la unidad.
Utilice conductores de prueba o accesorios que
sean apropiados para la aplicación. Consulte la
categoría y el voltaje nominal del conductor o
accesorio de prueba.
Inspeccione los conductores o los accesorios de
prueba antes de usarlos. Los elementos deben
estar limpios y secos, y el aislamiento debe estar en
buen estado.
Antes de abrir la caja, retire los conductores de
prueba del circuito y apague la unidad.
No cumplir con estas precauciones puede resultar
en lesiones graves o muerte.
No intente reparar esta unidad. No contiene piezas
a las que pueda prestar servicio el usuario.
No exponga esta unidad a temperaturas extremas o
alta humedad. Consulte las especificaciones.
No cumplir con estas precauciones puede resultar en
lesiones y puede dañar el instrumento.
ADVERTENCIA
PRECAUCIÓN
PELIGRO DE
DESCARGA ELÉCTRICA
Lesen Sie vor Betrieb oder
Wartung dieses Geräts die
Bedienungsanleitung sorgfältig durch.
Mangelndes Verständnis seiner sicheren
Handhabung kann zu schweren bzw.
tödlichen Verletzungen führen.
BEDIENUNGSANLEITUNG
95E0038 Rev. A
PRÜFGERÄT MODELL 600LS
ACHTUNG
SICHERHEITS-
WARNSYMBOL
Dieses Symbol macht Sie auf gefährliche oder riskante
Praktiken aufmerksam, die zu Schäden oder
Verletzungen führen können. Das Signalwort, wie
nachfolgend definiert, gibt den Ernst der Gefahr an.Der
dem Signalwort folgende Hinweis informiert darüber,
wie die Gefahr vermieden wird.
Akute Gefahr, die bei Nichtvermeiden zu schweren
Verletzungen oder zum Tod führt.
Gefahr, die bei Nichtvermeiden zu schweren
Verletzungen oder zum Tod führen kann.
Gefahr, die bei Nichtvermeiden zu Verletzungen führen
kann.
GEFAHR
ACHTUNG
VORSICHT
Dieses Gerät nicht Regen oder Feuchtigkeit
aussetzen. Das Berühren von Stromkreisen kann
zu schweren Verletzungen oder zum Tod führen.
Dieses Gerät nur zu seinem vom Hersteller be-
stimmten Zweck wie in dieser Anleitung
beschrieben verwenden. Andere Verwendungen
beeinträchtigen u.U. den vom Gerät gebotenen
Schutz.
Für den jeweiligen Einsatz geeignete
Messleitungen bzw. Zubehör verwenden.
Kategorie und Nennspannung von Messleitung
und Zubehör prüfen.
Messleitungen und Zubehör vor dem Einsatz
überprüfen. Alle Teile müssen sauber und trocken
sein, die Isolierung muss sich in gutem Zustand
befinden.
•Vor Öffnen des Gehäuses die Messleitungen vom
Stromkreis entfernen und das Gerät abschalten.
Nichtbeachten dieser Sicherheitsvorkehrungen kann
zu schweren Verletzungen oder zum Tod führen.
An diesem Gerät keine Reparaturversuche
unternehmen. Es enthält keine vom Benutzer
reparierbare Teile.
Das Gerät keinen extremen Temperaturen oder
hoher Feuchtigkeit aussetzen. (Siehe Technische
Daten)
Nichtbeachten dieser Sicherheitsvorkehrungen kann
zu Verletzungen oder Schäden am Gerät führen.
ACHTUNG
VORSICHT
BERÜHRUNGS-
GEFAHR
Einleitung
Diese Anleitung dient dazu, das Bedienpersonal mit der
sicheren Benutzung und Wartungsverfahren des Prüfgeräts
Modell 600LS vertraut zu machen.
Bitte lesen Sie vor der Benutzung des Geräts die Anleitung
vollständig durch und bewahren Sie diese für alle Benutzer
zugänglich auf. Ersatzanleitungen sind auf Wunsch kostenlos
erhältlich.
Sicherheit
Sicherheit ist bei der Benutzung und Wartung der Geräte von
Tempo wesentlich.Diese Anleitung und Markierungen auf den
Geräten informieren darüber, wie Gefahren und gefährliche
Praktiken bei der Benutzung dieses Geräts vermieden werden.
Beachten Sie alle Sicherheitshinweise.
Beschreibung
Das Prüfgerät 600LS ist von einem graublauen
Plastikgehäuse umgeben. Es hat rote und schwarze
Messleitungen, die mit Krokodilklemmen ausgerüstet and fest
am Gerät angebracht sind. Ein vieradriger Modularstecker mit
Kabel und zwei Leuchtdioden (LED) ermöglichen eine
modulare Polaritätsprüfung. Ein Schiebeschalter mit sechs
Positionen regelt die Betriebsfunktionen, und ein
Schiebeschalter mit drei Positionen erlaubt die Prüfung jeder
Leitung am Modularstecker.
Die Ton-, Pegel-, Widerstands- und Kapazitätsfunktionen
werden von einer internen 9 Volt-Batterie gespeist. Das
Hinzufügen einer zweiten 9 Volt-Batterie verbessert die
Versorgung mit Sprechbatteriestrom im Vergleich zu
Vorgängermodellen. (Siehe Abb.13) Die Polaritätsprüffunktion
ist leitungsgespeist.
Das Prüfgerät 600LS bietet die folgenden Funktionen:
Ton
Ein Dualton-Audioverfolgungssignal wird zur Identifizierung
von Kabelpaaren, Einführungsleitungen und I/O-
Kabelpaaren und zum Nachweis der Kontinuität von
einzelnen Adern verwendet. Das Signal wird auch mit
ausreichender Stärke ausgestrahlt, um von einem
Fernmeldetechniker-Prüfgerät oder einem Induktivverstärker
erkannt zu werden.
Pegel
Diese Position dient zum Prüfen des Leitungszustands. Kein
Ton zeigt eine tote Leitung oder umgekehrte Polarität an (0V-
2V).Ein Wechselton (hoch-tief) zeigt eine aktive, abgehobene
Leitung an (2V-28V).Ein gleichbleibender Ton zeigt ein aktive,
aufgelegte Leitung an (28V-48V).
Batterie
Ungefähr 18 V Sprechbatteriestrom stehen zur
Zweiwegkommunikation zur Verfügung, wenn zwei Batterien
eingelegt sind.
Widerstand
Diese Funktion bietet eine hörbare Anzeige verschiedener
Pegel von Leitungs- und Isolierungswiderstand.Während die
Messleitungen an eine Leitung mit geringem Widerstand
angeschlossen sind, erzeugt das Prüfgerät eine schnelle
Serie von Pieptönen.Während der Widerstand der geprüften
Leitung zunimmt, vergrößert sich das Interval zwischen den
Pieptönen entsprechend.
Kapazität
Eine hörbare Anzeige der Leitungskapazität wird von einem
eingebauten Lautsprecher erzeugt. Diese Prüfung kann
eingesetzt werden, um die Menge an Kapazität auf einer
Leitung anzuzeigen.
Polaritätsprüfung - Zwei zweifarbige LEDs bieten eine
visuelle Anzeige der Polarität der Zentralbatterie, die am
Modularstecker vorliegt. Rufstrom wird durch eine rotgrün
flimmernde LED (erscheint gelb) angezeigt. (Siehe
Polaritätsprüfung)
Wahlschalter Modularprüfung - Die obigen Prüfungen
mit Ausnahme der Polaritätsprüfung können durch das
Modularkabel auf Leitung 1 oder Leitung 2 durchgeführt
werden. (Siehe Modulare Leitungsprüfung)
Kalibrierung
Ein interner Widerstand mit einem Wert von einem Megaohm
dient in der Widerstandsfunktion dem Vergleich zum
Störwiderung der zu prüfenden Leitung oder Anlage.
Betrieb
Alle in den nachfolgenden Abschnitten beschriebenen Prüfungen
und Funktionen müssen mit der Zentralbatterie durchgeführt und
alle anderen Stromquellen von den zu prüfenden
Anlagen entfernt werden. Dies gilt nicht für Pegel- und
Leitungspolaritätsprüfungen.
Batterie- und Betriebsprüfung
Zur Durchführung einer Batterie- und Betriebsprüfung den
Schiebeschalter in die „Kapazitäts“-Position bringen. Ein Ton
sollte dann zur Anzeige einer vollen Batterie an der
Lautsprecheröffnung hörbar sein. Ist der Ton nicht hörbar, die
Messleitungen miteinander kurzschließen und den
Schiebeschalter in die „Widerstands“-Position bringen.
Dadurch sollte eine schnelle Serie von Pieptönen auf dem
Lautsprecher erzeugt werden.Sind keine Pieptöne hörbar, die
Batterien wie im Wartungsabschnitt beschrieben
austauschen und wiederholen. Ein Prüfgerät, das in einer der
Betriebsarten nach Einsetzen neuer Batterien nicht
funktioniert, sollte ersetzt
werden.
Kalibrierung
Während sich der
Schiebeschalter in der
„Widerstands“-Position
befindet, die Klemme der
roten Messleitung an die
Deckplatte oder den
Schraubenkopf neben der
Schiebeschalteröffnung
halten.Dadurch wird durch
einen internen Widerstand
ein Widerstand von
einem Megaohm auf
den Messleitungen des Prüfgeräts platziert. Das Gerät sollte
dann eine Serie von Pieptönen etwa im Sekundentakt
erzeugen. Dieser Pieptontakt wird nachfolgend als
„Kalibrierungstakt“ bezeichnet.Dieser Takt ist von Testgerät zu
Testgerät aufgrund von Komponentenunterschieden und
Batteriezuständen verschieden. (Siehe Abb.2)
Eine Leitung kann als frei von Isolierungsfehlern betrachtet
werden, wenn sie bei Prüfung mit der Widerstandsfunktion des
Prüfgeräts 600LS eine Serie von Pieptönen im Takt von
maximal einem Piepton pro 4 Sekunden, ungefähr 4
Megaohm, erzeugt.
Tonfunktion
Die „Ton“-Position wird verwendet, um Aderpaare zu
identifizieren und Kontinuität nachzuweisen. Das Dualton-
Verfolgungssignal wird mit einem gewöhnlichen Telefongerät
oder einem Fernmeldetechniker-Prüfgerät, bei dem sich der
Sprechmonitorschalter
in der Monitorposition
befindet, erkannt. (Siehe
Abb. 3)
Paaridentifizierung kann
wie folgt festgestellt
werden:Bevor der Versuch
unternommen wird ein
Aderpaar zu identifizieren,
sollte das Paar zunächst
auf Kurz- und Erdschlüsse
geprüft werden. Beide
Konditionen dämpfen
(verringern) das Signal
und erzeugen falsche
Anzeigen. Verfahren Sie
wie im Kapazitätsabschnitt
beschrieben, um zu
gewährleisten, dass das
Paar „frei“ ist. Nachdem das Paar „freigemacht“ wurde, den
Schiebeschalter in die „Ton“-Position bringen und die
Messleitungen an einem Ende der zu prüfenden Leitung und
das Fernmeldetechniker-Prüfgerät am anderen Ende der zu
prüfenden Leitung anschließen. Ein Paar mit einer „offenen“
Ader erzeugt einen tiefen Ton ähnlich wie bei einem
„gespaltenen“ Paar.
Nachweis von
Kontinuität
Um die Kontinuität einer
einzelnen Ader nachzuweisen,
wie folgt verfahren: Den
Schiebeschalter auf dem
Prüfgerät 600LS in die „Ton“-
Position bringen. Eine
Messleitung des Prüfgeräts
600LS an eine Ader des
Fernmeldetechniker-
Prüfgeräts anschließen, um
eine „Serien“-Verbindung zu
erstellen. Die verbleibende
Messleitung des 600LS an ein Ende der zu prüfenden Ader
anschließen.Die verbleibende Ader des Fernmeldetechniker-
Prüfgeräts als „Sonde“ benutzen und mit ihr das andere Ende
der Ader berühren und gleichzeitig auf den Ton hören, der im
Hörer des Fernmeldetechnier-Prüfgeräts erzeugt wird.(Siehe
Abb. 4)
Kontinuität kann auch durch
Verwendung der „Widerstands“-
Funktion des Prüfgeräts 600LS
nachgewiesen werden. Dies wird
durch den Nachweis eines
verhältnismäßigen Fehlens von
Widerstand in der zu prüfenden
Ader erreicht. Zu diesem Zweck
den Schiebeschalter in die
„Widerstands“-Position bringen
und eine Messleitung an einem
Ende der zu prüfenden Ader
anschließen. (Siehe Abb.5)
Schwarze
Messleitung
Rote Messleitung
Klemme berührt di
e
Schraube
Schalter in
Widerstandsposition
Langsamer
Pieptontakt
Abb. 2
Schalter in
To nposition
Abb. 3
Abb. 5
Schalter in
Tonposition
Abb. 4
APPAREIL DE VÉRIFICATION
MODÈLE
600LS
cord and plug provided and by observing the two LEDs.
Place three-position switch in modular position.
When C.O. battery is applied to the contacts of the plug,
the LEDs will glow red or green depending on the polarity
of the applied voltage.
1. A green LED lighted on either line indicates correct
polarity with negative battery on jack contacts 3 or 5,
respectively.
2 A red LED lighted on either line indicates reversed
polarity or the presence of positive battery on jack
contacts 3 or 5, respectively.
3. The presence of AC voltage (approximately 9 volts or
above) is indicated when both
the red and green LEDs light
and flicker (appearing yellow).
Modular Line Testing
Lines terminated with a modular
outlet can be tested for any or all
tests provided by the 600LS test
set. (See Fig. 12)
Proceed by inserting the modular
plug in to the modular outlet to be
tested.Select the line (1 or 2) to be
tested with the three-position
modular tester slide switch.Select
the test function and proceed as
described in the above
paragraphs.
Station Ground Test
The 600LS is capable of
performing an additional special
function for TESTING STATION
GROUND providing CO battery is present at each outlet
under test.
1. Place function switch in OFF position.
2. Place modular switch in Line 2 position (UP).
3. Insert modular cord in outlet.
4. Station Ground is present when red LED on Line 2 is
lit.
NOTE: A positive test is verification of STATION
GROUND present on the yellow conductor of standard
four conductor wiring.
Specifications
Electrical
Battery
Output Voltage
(Talk Battery into 600 Ohm) . . . . . . . . . .9.8 VDC
Tone
Output Power (into 600 Ohm) . . . . . . . . . .+7dBm
Output Frequency (nominal) . . . . . . .890/960 Hz
Tone . . . . . . . . . . . . . . ..............alternating
Warble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Hz
Level
No Tone . . . . . . . . . . . . . . . . . . . . . .less than 3V
Warble Tone . . . . . . . . . . . . . . . . . . . . .3V to 30V
Solid Tone . . . . . . . . . . . . . . . . . . .more than 30V
Voltage Protection (into a 600 Circuit) . . .60 VDC
Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 VDC
(NEDA 1604, JIS 006P or IEC 6LR61)
Battery Life . . . . . . . . . . . . . . . . . . . . . . .50 hours
Physical
Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.5”
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.4”
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1"
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 oz.
Operating/Storage Conditions
Operating Temperature:
Celsius . . . . . . . . . . . . . . . . . . . . . . .0°C to 50°C
Fahrenheit . . . . . . . . . . . . . . . . . . .32°F to 122°F
Storage Temperature:
Celsius . . . . . . . . . . . . . . . . . . . . . .-50°C to 75°C
Fahrenheit . . . . . . . . . . . . . . . . . . .-58°F to 167°F
Maintenance
Battery Replacement
1. Remove the battery cover.
2. Remove and replace battery. (Observe polarity.)
3. Replace battery cover.
Cleaning
Periodically wipe with a damp cloth and mild detergent; do
not use abrasives or solvents.
Fig. 12
Fig. 13
the other end of the conductor under test and listen for
beeps to be emitted from the test set. A rapid series of
beeps indicates continuity. Compare the results by
alternately shorting the test leads and connecting the test
set to the test conductor. No discernible difference should
be noted in the beep rate.
Battery
Operation
If a source of “talk”
battery is required, place
the slide switch in the
“batt” position. Then
connect lineman's test
sets or telephones in
series with the test set
lead. (See Fig. 6)
Resistance
Testing
To test relative resistance
levels between two
conductors, or between a
single conductor and
ground, place the slide switch in the “resistance” position.
The test set will emit a series of beeps when the test set
leads are shorted or connected to a resistance circuit.The
time interval between beeps increases as the resistance
of the circuit being tested is increased.Thus, a solid short
produces a rapid series of beeps, and grasping the test
lead clips with one in each hand produces beeps at a much
slower rate.
Testing for Shorts
To test a pair of conductors for shorts, connect the 600LS
test set to the pair. Place the slide switch in the
“resistance” position and listen for “beeps” to be emitted
from the test set. A rapid
series of beeps indicates a
solid short. (See Fig. 7)
Testing for Ground
A “ground” is similar to a
short in that it is caused by an
insulation breakdown
between two conductors. In
this case, the breakdown is
between the facilities and
ground. To test a circuit or
pair for “grounds”, proceed
as follows. Place the slide
switch in the “resistance”
position and listen for beeps to be emitted from the test
set.A rapid series of beeps indicates a low resistance path
to ground. (See Fig. 8)
Testing for
Crosses
A cross is basically a short
between a conductor of
another pair. To test for
crosses in a given group of
pairs, place the slide switch
in the “resistance” position
and connect one test lead to
a conductor of the first pair
in the group. Connect the
other test lead to the
remaining conductors, one
at a time. A cross will be
indicated when the test set emits a series of beeps.
Proceed by moving the initial test lead to each conductor
in turn and testing it against the remaining conductors.
(See Fig. 9)
Capacitance
The “cap” position is
used to estimate the
number of ringers on a
line. (See Fig. 10)
Before attempting this
test, the line should be
tested for C.O. battery,
shorts and grounds. Any
of these conditions will
produce false indications.
After the line (pair) has
been “cleared”, connect
the leads of the test set to
the line and place the
slide switch in the “cap” position.
A continuous tone indicates no ringers on the line. A
beeping tone at approximately one per second indicates
the line is terminated by one ringer.Each additional ringer
will decrease the beep rate by one second;therefore:
1 ringer = 1 (second per beep)
2 ringers = 2 (seconds per
beep), etc.
This test will also indicate the
capacitance (related to the
length) of a line not terminated
by a ringer. The line length
must be at least 100 feet or
longer. If the line length is
approximately 30,000 feet, or
six miles long, the beep rate
will be similar to a one ringer
load.
Level Testing
To test the relative level of
voltage online, do the following:
Place the slide switch in the
“level” position. Connect red
lead to ring of the line under test.
(See Fig. 11) Connect black
lead to tip of the line under test.
Check for the following
conditions:
1. No tone emitted from the
test set means the voltage
is less than 3 VDC.
2. An alternating tone being emitted indicates a voltage
of 3V to 30 VDC on the line, resulting from a busy or
talking line.
3. A single solid tone being emitted indicates a voltage
of 30V to 48 VDC on the line, indicating a line not in
use (or office battery).
4. An alternating tone accompanied by a hum or buzz
being emitted indicates voltage of 3V to 30VAC on
the line.
5. A single solid tone accompanied by a hum or buzz
being emitted indicates a voltage of 30V to 48 VAC
on the line.
If the line is suspected to be good but this test results in
no tone, the polarity may be reversed. Reverse the test
leads and repeat test.
See modular polarity test for additional test of line
reversal.
Polarity Testing
Polarity of the first and second lines on a modular
connector can be determined by the use of the modular
Fig. 6
Fig. 7
Fig. 8
Fig. 10
Fig. 9
Fig. 11
WARNING
Before opening the case, remove the test
leads from the circuit and shut off the unit.
Failure to observe these warnings can result
in severe injury or death.
Test de polarité
La polarité de la première et deuxième lignes sur un
connecteur modulaire peut être déterminée à l'aide de du
cordon et de la prise modulaire fournis et en observant les
deux DEL.Placez le commutateur à trois positions en position
modulaire.
Lorsque la batterie centrale est appliquée aux contacts de la
prise, la DEL s'illumine de rouge ou de vert en fonction de la
polarité de la tension appliquée.
1. Une DEL verte allumée sur l'une ou l'autre ligne indique
une polarité correcte avec une batterie négative sur les
contacts 3 ou 5 respectivement.
2. Une DEL rouge allumée sur l'une ou l'autre ligne indique
une polarité inversée ou la présence d'une batterie
positive sur les contacts 3 ou 5
respectivement.
3. La présence de tension CA
(environ 9 volts ou plus) est
indiquée quand les deux DEL
rouge et verte s'allument
et s'illuminent de façon
intermittente (sont d'apparence
jaunâtre).
Test de ligne
modulaire
Les lignes terminées par une sortie
modulaire peuvent être testées à
l'aide de l'un ou de l'ensemble des
tests offerts par l'appareil de
vérification 600LS. (Voir fig. 12.)
Procédez en insérant la fiche
modulaire dans la sortie modulaire à
tester. Sélectionnez la ligne (1 ou 2)
à tester à l'aide de l'interrupteur à
glissière à trois positions du testeur
modulaire. Sélectionnez la fonction
de test et procédez tel que décrit
dans les paragraphes ci-dessus.
Test de terre de station
Le 600LS est capable d'effectuer une fonction spéciale
supplémentaire pour TESTER LA TERRE DE STATION à
condition que la batterie centrale soit présente à chaque sortie
testée.
1. Mettez le commutateur de fonction sur OFF.
2. Placez le commutateur modulaire en position Ligne 2
(HAUT).
3. Insérez le cordon modulaire dans la sortie.
4. La terre de station est présente si la DEL ROUGE de la
ligne 2 s'allume.
REMARQUE : Un test positif constitue une vérification de la
présence de TERRE DE STATION sur le conducteur jaune
d'un fil standard à quatre conducteurs.
Caractéristiques
Caractéristiques électriques
Batterie
Tension de sortie
(batterie de conversation pour 600 ohms) . . .9,8 V c.c.
Tonalité
Puissance de sortie (dans 600 Ohms) . . . . .+7 dBm
Fréquence de sortie (nominale) . . . . . . . .890/960 Hz
Tonalité . . . . . . . . . . . . . . . . .............alternative
Modulée . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Hz
Niveau
Aucune tonalité . . . . . . . . . . . . . . . . . . .moins de 3V
Tonalité modulée . . . . . . . . . . . . . . . . . . . . . .3 à 30 V
Tonalité continue . . . . . . . . . . . . . . . . . .plus de 30 V
Protection contre les surtensions
(dans un circuit de 600 Ohms) . . . . . . . . . 0,60 V c.c.
Batterie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 V c.c.
(NEDA 1604, JIS 006P ou IEC 6LR61)
Durée de vie de la batterie . . . . . . . . . . . . .50 heures
Caractéristiques physiques
Longueur . . . . . . . . . . . . . . . . . . . . . . . .14 cm (5,5 po)
Largeur . . . . . . . . . . . . . . . . . . . . . . . . .6,1 cm (2,4 po)
Hauteur . . . . . . . . . . . . . . . . . . . . . . . . . .2,5 cm (1 po)
Poids . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142 g (5 oz)
Conditions de fonctionnement
et de stockage
Température de fonctionnement :
Degrés Celsius . . . . . . . . . . . . . . . . . . . . . .0 à 50 °C
Degrés Fahrenheit . . . . . . . . . . . . . . . . . .32 à 122 °F
Température de stockage :
Degrés Celsius . . . . . . . . . . . . . . . . . . . .-50 à 75 °C
Degrés Fahrenheit . . . . . . . . . . . . . . . . .-58 à 167 °F
Entretien
Remplacement de la batterie
1. Enlevez le couvercle de batterie.
2. Retirez la batterie et remplacez-la (respectez la polarité).
3. Replacez le couvercle de batterie.
Nettoyage
Nettoyez le boîtier périodiquement à l'aide d'un chiffon humide
et d'un détergent doux; n'utilisez pas de nettoyants abrasifs ni
de solvants.
Fig. 12
Emplacement de batterie
supplémentaire pour alimenter
la batterie de conversation
Fig. 13
fil de test à l'une des extrémités du conducteur testé. (Voir
fig. 5.)
Connectez le fil de test restant à un bon conducteur attaché
au préalable à l'autre extrémité du conducteur à tester, puis
écoutez pour voir si des signaux sonores sont émis par
l'appareil de vérification. Une succession rapide de signaux
sonores indique la
présence de continuité.
Comparez les résultats en
procédant alternativement
au court-circuitage des fils
de test puis à la connexion
de l'appareil de vérification
au conducteur à tester. Il
ne devrait y avoir aucune
différence notable en
termes de fréquence des
signaux sonores.
Fonctionnement
de la batterie
Si une source de batterie de
« conversation » est requise,
placez l'interrupteur à
glissière en position « batt ».
Connectez ensuite, en
série, des appareils de vérification de monteur de ligne ou des
téléphones au fil de l'appareil de vérification. (Voir fig. 6.)
Test de résistance
Pour tester les niveaux de résistance relative entre deux
conducteurs ou entre un simple conducteur et la terre, mettez
l'interrupteur à glissière en position « résistance ». L'appareil
de vérification émet une série de signaux sonores quand les
fils de test sont court-circuités ou connectés à un circuit de
résistance. L'intervalle de temps entre les signaux sonores
augmente à mesure que la résistance du circuit testée est
accrue. Ainsi, un court-circuit franc produira une série de
signaux sonores très rapide alors que, si vous saisissez
chaque pince de fil de test dans une main, les signaux sont
produits beaucoup plus lentement.
Vérification de
courts-circuits
Pour tester la présence de
courts-circuits sur une paire
de conducteurs, connectez
l'appareil de vérification 600LS
à la paire en question. Mettez
l'interrupteur à glissière en
position « résistance » et
écoutez si l'appareil de
vérification émet des signaux
sonores. Une succession
rapide de signaux sonores
indique la présence d'un court-
circuit franc. (Voir fig. 7.)
Vérification de
la terre
Une « terre » est similaire à un
« court-circuit » dans la
mesure où elle est causée par
une rupture d'isolation entre
deux conducteurs. Dans ce
cas-ci, la rupture se produit
entre les installations et la
terre. Pour tester la présence
d'une terre sur un circuit ou
une paire, procédez comme
suit : Mettez l'interrupteur
à glissière en position
« résistance » et écoutez si
l'appareil de vérification émet
des signaux sonores. Une
succession rapide de signaux
sonores indique la présence
d'une faible résistance à la
terre. (Voir fig. 8.)
Vérification des croisements
Un croisement est un court-circuit entre le conducteur d'une
paire et le conducteur d'une autre paire.Pour vérifier s'il y a des
croisements dans un groupe de paires donné, mettez
l'interrupteur à glissière en
position « résistance » et
connectez un fil de test
à un conducteur de la
première paire du groupe.
Connectez l'autre fil de test
aux conducteurs restants,
un par un. Il y a croisement
si l'appareil de vérification
émet une série de signaux
sonores. Continuez en
plaçant tour à tour le fil
de test initial sur chaque
conducteur et en le
testant par rapport aux
conducteurs restants.(Voir
fig. 9.)
Capacité
La position « cap » sert à estimer le nombre de sonneries sur
une ligne. (Voir fig. 10.)
Avant d'effectuer ce test, testez la ligne pour voir s'il y a
présence de batterie centrale, de courts-circuits ou de terre.
Chacun de ces cas produira de fausses indications.
Une fois la ligne (paire) approuvée, connectez les fils de test
de l'appareil de vérification à la ligne et mettez l'interrupteur à
glissière en position « cap ».
Une tonalité continue indique
l'absence de sonneries sur la
ligne. Un signal d'une fréquence
d'environ un signal par seconde
indique que la ligne est terminée
par une sonnerie. Chaque
sonnerie supplémentaire réduit
la fréquence des signaux
sonores d'une seconde; par
conséquent :
1 sonnerie = 1 (seconde par
signal sonore)
2 sonneries = 2 (secondes par
signal sonore), etc.
Ce test indique également la
capacité (relative à la longueur)
d'une ligne non terminée par une
sonnerie. La longueur de la ligne
doit être d'au moins 30,5 m (100
pi) ou plus. Si la ligne mesure
environ 9144 m (30 000 pi) ou
9,6 km (6 milles) long, la
fréquence des signaux sonores
sera similaire à une charge de
sonnerie.
Vérification du
niveau
Pour tester le niveau relatif de
tension en ligne, procédez comme
suit : Mettez l'interrupteur à glissière en position « niveau ».
Connectez le fil rouge à la sonnerie de la ligne testée.(Voir fig.
11.) Connectez le fil noir à la pointe de la ligne testée.Vérifiez
les points suivants :
1. Si aucune tonalité n'est émise par l'appareil de
vérification, cela signifie que la tension est inférieure à
3 V c.c.
2. L'émission d'une tonalité alternative indique une tension
de 3 V à 30 V c.c. sur la ligne, due à une ligne occupée.
3. L'émission d'une tonalité continue indique une tension de
30 V à 48 V c.c. sur la ligne, et donc une ligne inutilisée
(ou une batterie centrale).
4. Une tonalité alternative accompagnée d'un ronflement
ou d'un bourdonnement indique la présence d'une
tension de 3 V à 30 V c.a. sur la ligne.
5. Une tonalité continue accompagnée d'un ronflement ou
d'un bourdonnement indique la présence d'une tension
de 30 V à 48 V c.a. sur la ligne.
Si vous soupçonnez que la ligne est en bon état mais que ce
test ne révèle aucune tonalité, il se peut que la polarité soit
inversée. Inversez les fils de test et recommencez le test.
Voir le test de polarité modulaire pour un test supplémentaire
de l'inversion de ligne.
Interrupteur en
position batterie
Fig. 6
Interrupteur en
position résistance
Fig. 7
Interrupteur en
position résistance
Fig. 8
Interrupteur en
position capacité
Tête
Nuque
Fig. 10
Interrupteur en
position résistance
1ère paire
2ème paire
Fig. 9
Interrupteur en
position niveau
Tête – Fil noir
Nuque – Fil rouge
Fig. 11
AVERTISSEMENT
Avant d'ouvrir le boîtier, débranchez l’appareil du
circuit et éteignez-le. Le non-respect de ces
avertissements peut causer des blessures graves
ou la mort.
Tempo – Mesa | Formerly Progressive Electronics
Telephone: +1 815 397-4279
Toll-free in the US and Canada: 1 800 282-7941
Facsimile: +1 815 397-1865
www.tempo.textron.com
One-Year Limited Warranty
Tempo warrants to the original purchaser of these goods
for use that these products will be free from defects in
workmanship and material for one year, excepting normal
wear and abuse.
For all Test Instrument repairs, you must first request a
Return Authorization Number by contacting our Customer
Service department at:
toll free in the US and Canada 800 642-2155
Telephone +1 760 598-8900
Facsimile +1 760 598-5634.
This number must be clearly marked on the shipping label.
Ship units Freight Prepaid to:
Tempo Repair Center,
1390 Aspen Way, Vista CA 92081 USA.
Mark all packages:
Attention:TEST INSTRUMENT REPAIR.
For items not covered under warranty (such as dropped,
abused, etc.) repair cost quote available upon request.
Note: Prior to returning any test instrument, please check
to make sure batteries are fully charged.
Tempo - Mesa | Anciennement
Progressive Electronics
Téléphone : +1 815 397-4279
Numéro sans frais aux États-Unis et au Canada :
1 800 282-7941
Télécopieur : +1 815 397-1865
www.tempo.textron.com
Garantie limitée d'un an
Tempo garantit à l’acheteur initial de ces produits que
ceux-ci sont libres de défauts de matériaux et de vices de
fabrication pendant une période d’un an, exception faite de
l’usure normale et des abus.
Pour toute réparation d'appareil de vérification, vous
devez obtenir un numéro d'autorisation de retour de
marchandise auprès de notre service à la clientèle en
appelant le +1 760 598-8900 Télécopieur +1 760 598-
5634. (
Numéro sans frais aux États-Unis et au Canada :
800 642-2155).Ce numéro doit être clairement indiqué sur
l’étiquette d’envoi. Expédiez les appareils port payé à
Tempo Repair Center,
1390 Aspen Way, Vista CA 92081 États-Unis.
Veuillez inscrire la mention suivante sur tous les colis :
Attention:TEST INSTRUMENT REPAIR.
Pour les articles non couverts par la garantie (chute,
utilisation abusive, etc.), un devis de réparation est
disponible sur demande.
Remarque : avant de renvoyer un instrument de
vérification, veuillez vous assurer que la batterie est
encore chargée.
Tempo – Mesa | ehemals Progressive Electronics
001-480-966-2931 • Fax: 001-480-967-8602
Gebührenfrei in den USA und Kanada:
1-800-282-7941
www.tempo.textron.com
Einjährige beschränkte Garantie
Tempo garantiert dem Erstkäufer dieser Produkte, dass
sie unter Ausschluss von normalem Verschleiß oder
Missbrauch ein Jahr lang frei von Material- und
Herstellungsfehlern sind.
Bei allen Reparaturen an Prüfgeräten muss zunächst
eine Rücksendungserlaubnisnr. (RA No.) bei der
Kundendienstabteilung unter:
Gebührenfrei in den USA und Kanada:
800 642-2155
Telephone +1 760 598-8900
Fax +1 760 598-5634.
Diese Nummer muss gut lesbar auf dem Versandetikett
angegeben werden. Alle Geräte freigemacht an
Tempo Repair Center,
1390 Aspen Way, Vista CA 92081 USA
A senden und mit
Attention “TEST INSTRUMENT REPAIR“ beschriften.
Bei Geräten ohne Garantieschutz (z.B. gefallene oder
missbrauchte Geräte) kann ein Kostenvoranschlag für die
Reparatur eingeholt werden.
Hinweis: Bitte laden Sie vor dem Einsenden die Batterien
des Geräts vollständig auf.
invertido la polaridad. Invierta los conductores de prueba y
repita la prueba.
Consulte la prueba modular de polaridad por las pruebas
adicionales de inversión de la línea.
Prueba de la polaridad
Se puede determinar la polaridad de la primera y segunda
línea en un conector modular mediante el uso del cordón
modular y el enchufe proporcionado y observando los dos
LED.Coloque el interruptor deslizante en la posición modular.
Cuando la batería de la oficina central esté aplicada a los
contactos del enchufe, los LED destellarán de color rojo o
verde, dependiendo de la polaridad del voltaje aplicado.
1. Un LED verde iluminado en cualquiera de las líneas
indica la polaridad correcta con una batería negativa
en los contactos 3 o 5
respectivamente del conector.
2 Un LED rojo iluminado en
cualquiera de las líneas indica
que la polaridad está invertida o
la presencia del positivo de una
batería en los contactos 3 o 5,
respectivamente del conector.
3. Se indica la presencia de voltaje
de CA (aproximadamente 9
voltios o más) cuando ambos
LED (verde y rojo) se encienden
y destellan (pareciendo
amarillo).
Prueba modular
de líneas
Las líneas terminadas con una toma
de corriente modular se pueden
probar usando una o todas las
pruebas proporcionadas por la
unidad de prueba 600 LS. (Consulte
la Figura 12)
Inserte el enchufe modular en la
salida modular que se va a probar.
Seleccione la línea (1 ó 2) a ser probada con el interruptor
deslizante de tres pociones del probador modular. Seleccione
la función de prueba y continúe como se describe en los
párrafos anteriores.
Prueba de tierra de la estación
El 600LS es capaz de realizar una función adicional especial
para PROBAR TIERRAS DE LA ESTACIÓN siempre que haya
una batería de oficina central presente en cada toma de
corriente bajo prueba.
1. Coloque el interruptor de funciones en la posición de
APAGADO (OFF).
2. Coloque el interruptor modular en la posición de la línea
2 (HACIA ARRIBA).
3. Inserte el cordón modular en la toma de corriente.
4. Hay una conexión a tierra presente cuando el LED de la
línea 2 está iluminado.
NOTA: Una prueba positiva es una verificación de que hay
una TIERRA DE LA ESTACIÓN en el conductor amarillo de
cableado estándar de cuatro conductores.
Especificaciones
Eléctrica
Batería
Voltaje de salida
(Batería de habla en 600 ohmios) . . . . . . . . . . .9.8Vdc
To no
Salida de potencia (en 500 Ohmios) . . . . . . .+7dBm
Frecuencia de salida (nominal) . . . . . . . .890/960 Hz
Tono . . . . . . . . . . . . . . . . . . .............alternante
Tono modulado . . . . . . . . . . . . . . . . . . . . . . . . . .6 Hz
Nivel
Sin tono . . . . . . . . . . . . . . . . . . . . . . . . .menos de 3V
Tono modulado . . . . . . . . . . . . . . . . . . . . . .3V a 30V
Tono sólido . . . . . . . . . . . . . . . . . . . . . . .más de 30 V
Protección de voltaje
(con un circuito de 600) . . .60 Vdc
Batería . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Vdc
(NEDA 1604, JIS 006P o IEC 6LR61)
Duración de la batería . . . . . . . . . . . . . . . . .50 horas
Características físicas
Longitud . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.5 pulg.
Ancho . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.4 pulg.
Altura . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 pulg.
Peso . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 onzas
Condiciones de funcionamiento y
almacenamiento
Temperatura de funcionamiento:
Centígrados . . . . . . . . . . . . . . . . . . . . . . .0°C a 50°C
Fahrenheit . . . . . . . . . . . . . . . . . . . . . . .32°F a 122°F
Temperatura de almacenamiento:
Centígrados . . . . . . . . . . . . . . . . . . . . .-50°C a 75°C
Fahrenheit . . . . . . . . . . . . . . . . . . . . . .-58°F a 167°F
Mantenimiento
Cambio de la batería
1. Extraiga la cubierta de la batería
2. Extraiga y cambie la batería (observe la polaridad)
3. Vuelva a instalar la cubierta de la batería
Limpieza
Limpie periódicamente con un paño húmedo y detergente
suave; no use abrasivos ni solventes.
Fig. 12
Colocación de la
batería adicional
para el suministro
de batería de habla
Fig. 13
que se está probando.Para hacer esto, coloque el interruptor
deslizante en la posición de "resistencia" y conecte un
conductor de prueba al otro extremo del conductor que se va
a probar. (Consulte la Figura 5)
Conecte el conductor de prueba restante a un conductor
bueno que se haya fijado al otro extremo del conductor bajo
prueba y escuche los
zumbidos que se emitirá
desde la unidad de prueba.
Una serie rápida de
zumbidos indica que hay
continuidad. Compare los
resultados cortocircuitando
alternadamente los
conductores de prueba y
conectando la unidad de
prueba al conductor de
prueba. No se debe
observar una diferencia
notable en la velocidad de
los zumbidos.
Operación de
la batería
Si se requiere una fuente
de batería de "habla",
coloque el interruptor deslizante en la posición de "batería"
(batt). Conecte luego unidades de prueba o teléfonos de
instalador de líneas en serie con el conductor de la unidad de
prueba. (Consulte la Figura 6)
Prueba de la resistencia
Para probar niveles de resistencia relativa entre dos
conductores, o entre un solo conductor y tierra, coloque el
interruptor deslizante en la posición de "resistencia"
(resistance).La unidad emitirá una serie de zumbidos cuando
los conductores de la unidad estén en corto circuito o cuando
estén conectados a un circuito de resistencia. El intervalo de
tiempo entre zumbidos aumenta a medida que se aumente la
resistencia del circuito bajo prueba. Por lo tanto, un corto
circuito sólido produce una serie rápida de zumbidos, y tomar
los clip del conductor de
prueba, uno en cada mano,
produce zumbidos a una
velocidad mucho más lenta.
Prueba de cortos
circuitos
Para probar si un par de
conductores está en corto
circuito, conecte la unidad de
prueba 600LS al par. Coloque
el interruptor deslizante en la
posición de "resistencia"
(resistance) y escuche los
"zumbidos" que emitirá la
unidad de prueba. Una serie
rápida de zumbidos indica que
hay un corto circuito sólido.(Consulte la Figura 7)
Prueba de la tierra
Una "tierra" es similar a un
corto circuito que está
causado por una falla de
aislamiento entre dos
conductores. En este caso,
la falla está entre las
instalaciones y la tierra. Para
probar si un circuito o un par
tiene conexiones a "tierra",
haga lo siguiente. Coloque el
interruptor deslizante en la
posición de "resistencia" y
escuche los zumbidos que
emitirá la unidad de prueba.
Una serie rápida de zumbidos
indica una vía de baja
resistencia a tierra. (Consulte
la Figura 8)
Prueba de cruces
Un cruce es, básicamente, un corto circuito entre un
conductor de otro par. Para probar si hay cruces en un grupo
determinado de pares,
coloque el interruptor
deslizante en la posición
de "resistencia" y conecte
un conductor de prueba a
un conductor del primer
par del grupo. Conecte el
otro conductor de prueba a
los conductores restantes
de a uno por vez. Se
indicará la existencia de un
cruce cuando la unidad de
prueba emita una serie de
zumbidos. Mueva el
conductor de prueba inicial
a otro conductor por turnos
y pruébelo contra los
conductores restantes.
(Consulte la Figura 9)
Capacidad
Se usa la posición de “cap” para calcular la cantidad de
timbres en una línea. (Consulte la Figura 10)
Antes de intentar esta prueba, se debe probar si la línea tiene
batería de oficina central, cortos circuitos y conexiones a tierra.
Cualquiera de estas condiciones causará indicaciones falsas.
Después de haber "despejado"
la línea (par), conecte los
conductores de la unidad de
prueba a la línea y coloque el
interruptor deslizante en la
posición de "cap".
Un tono continuo indica que no
hay timbres en la línea. Un
zumbido intermitente de
aproximadamente uno por
segundo indica que la línea está
terminada por un timbre. Cada
timbre adicional disminuirá en un
segundo la velocidad de los
zumbidos; por lo tanto:
1 timbre = 1 (segundo por
zumbido)
2 timbres = 2 (segundos por
zumbido), etc.
Esta prueba también indica la
capacidad (en relación con el
largo) de una línea no terminada
por un timbre. El largo de la línea
debe ser de por lo menos 100 pies
o más.Si el largo de la línea es de
aproximadamente 30,000 pies, o
seis millas de largo, la velocidad
del zumbido será similar a la de
una carga de un timbre.
Prueba de nivel
Para probar el nivel relativo del voltaje en línea, haga lo
siguiente: Coloque el interruptor deslizante en la posición de
"nivel" (level). Conecte el conductor rojo al hilo B de la línea
bajo prueba. (Consulte la Figura 11) Conecte el conductor
negro al hilo A de la línea bajo prueba. Compruebe las
siguientes condiciones:
1. Si la unidad de prueba no emitió ningún tono quiere decir
que el voltaje es de menos de 3VCC.
2. La emisión de un tono alternante indica que hay un
voltaje de 3V a 30 VCC en la línea, resultado de una
línea ocupada o de una línea hablando.
3. La emisión de un solo tono sólido indica que hay un
voltaje de 30 a 48 VCC en la línea, esto indica que hay
una línea que no se usa (o la batería de la oficina).
4. Un tono alternante acompañado por la emisión de un
zumbido indica que hay un voltaje de 3V a 30 VCC en la
línea.
5. Un solo tono sólido acompañado de la emisión de un
zumbido indica que hay un voltaje de 30 a 48VCA en la
línea.
Si se sospecha que la línea está en buen estado, pero esta
prueba resulta en que no hay tono, es posible que se haya
Interruptor en la
posición de batería
Fig. 6
Interruptor en la posición
de resistencia
Fig. 7
Interruptor en la posición
de resistencia
Fig. 8
Interruptor en la posición
de capacidad
Hilo A
Hilo B
Fig. 10
Interruptor en la posición
de resistencia
1er par
2do par
Fig. 9
Interruptor en la
posición de nivel
Hilo A – conductor
negro
Hilo B – conductor
rojo
Fig. 11
ADVERTENCIA
Antes de abrir la caja, retire los conductores de prueba
del circuito y apague la unidad.
No cumplir con estas advertencias puede resultar en
lesiones graves o muerte.
Tempo-Mesa | Anteriormente conocida como
Progressive Electronics
Teléfono: +1 815 397-4279
Llamada gratis desde los EE.UU. y Canadá:
1 800 282-7941
Fax: +1 815 397-1865
www.tempo.textron.com
Garantía limitada de un año
Te mpo garantiza este equipo contra defectos de material o
de mano de obra, por el periodo de un año a partir de la fecha
de compra. Esta garantía no se aplicara a ningún defecto,
falla o daño causado por uso indebido o mantenimiento
inadecuado.
Si su equipo necesita ser reparado usted debe solicitar un
numero de Autorización de Devolución de Material (RMA #)
contactando el departamento de servicios al consumidor de
Tempo a los siguientes números telefónicos:
Llamadas gratis dentro de los EE.UU. y Canadá:800-642-2155
Tel: +(760) 598-8900
Fax: +(760) 598-5634
Después de obtener él numero de autorización envié la
unidad con el flete prepagado a la siguiente dirección:
TEMPO
Attention:TEST INSTRUMENT REPAIR
RMA#______________
1390 Aspen Way,
Vista, CA 92081 USA
Si el equipo esta fuera de garantía usted puede obtener una
cotización del costo de reparación comunicándose con el
departamento de servicios al consumidor a los teléfonos ya
indicados.
Nota: Antes de devolver este equipo para ser reparado
compruebe que las baterías están cargadas y debidamente
instaladas.
Wenn Zentralbatterie auf den Kontakten des Steckers anliegt,
leuchten die LEDs je nach Polarität der vorhandenen
Spannung rot oder grün auf.
1. Das Aufleuchten einer grünen LED auf einer der beiden
Leitungen zeigt korrekte Polarität mit negativer Batterie
jeweils an den Buchsenkontakten 3 oder 5 an.
2 Das Aufleuchten einer roten LED auf einer der beiden
Leitungen zeigt umgekehrte Polarität oder das
Vorhandensein einer positiven Batterie jeweils an den
Buchsenkontakten 3 oder 5 an.
3. Das Vorhandensein einer Wechselspannung (ungefähr 9
V oder höher) wird angezeigt, wenn sowohl die rote als
auch die grüne LED aufleuchten und flimmern (erscheint
gelb).
Prüfen einer
modularen Leitung
Alle Prüfungen, die mit dem Prüfgerät
600LS möglich sind, können an
Leitungen, die mit einem modularen
Ausgang abgeschlossen sind,
durchgeführt werden.(Siehe Abb. 12)
Dazu den Modularstecker in die zu
prüfende Modularsteckdose einführen.
Die zu prüfende Leitung (1 oder 2) mit
dem Dreipositionsschiebeschalter
für Modularprüfung wählen. Die
Prüffunktion wählen und wie in den
obenstehenden Absätzen beschrieben
fortfahren.
Stationserdung prüfen
Das 600LS bietet eine weitere
Sonderfunktion zum PRÜFEN DER
STATIONSERDUNG, vorausgesetzt,
dass Zentralbatterie an jeder zu
prüfenden Steckdose vorliegt.
1. Den Funktionsschalter in die
AUS-Position bringen.
2. Den Modularschalter in die Position für Leitung 2 (OBEN)
bringen.
3. Das Modularkabel in die Steckdose einführen.
4. Stationserdung liegt vor, wenn die LED auf Leitung 2
aufleuchtet.
HINWEIS: Eine positive Prüfung ist die Verifizierung von
STATIONSERDUNG, die auf der gelben Ader einer
standardmäßigen vieradrigen Verkabelung vorliegt.
Technische Daten
Elektronik
Batterie
Ausgangsspannung
(Sprechbatterie in 600 ) . . . . . . . . . . . . . .9,8 V DC
To n
Ausgangsleistung (in 600 ) . . . . . . . . . . . . .+7 dBm
Ausgangsfrequenz (nominell) . . . . . . . . .890/960 Hz
To nabwechselnd
Wobbelfrequenz . . . . . . . . . . . . . . . . . . . . . . . . .6 Hz
Pegel
Kein Ton . . . . . . . . . . . . . . . . . . . . . . .weniger als 3 V
Wobbelfrequenz . . . . . . . . . . . . . . . . . . . . .3 bis 30 V
Dauerton . . . . . . . . . . . . . . . . . . . . . . .mehr als 30 V
Spannungssicherung
(in eine 600 Leitung) . . . . . . . . . . . . . . . . . . 60 V DC
Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 V DC
(NEDA 1604, JIS 006P oder IEC 6LR61)
Lebensdauer der Batterie . . . . . . . . . . . .50 Stunden
Hardware
Länge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 cm
Breite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 cm
Höhe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2,5 cm
Gewicht . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142 g
Betriebs- und Lagerbedingungen
Betriebstemperatur:
0 bis 50 °C
Lagertemperatur:
-50 bis 75 °C
Wartung
Austausch der Batterie
1. Die Batteriefachabdeckung entfernen.
2. Die Batterie unter Beachtung der Polarität austauschen.
3. Die Batteriefachabdeckung wieder anbringen
Reinigung
Das Gerät gelegentlich mit einem feuchten Tuch und mildem
Reinigungsmittel abwischen. Keine Scheuer- oder
Lösungsmittel verwenden.
Abb. 12
Platzierung einer
zusätzlichen Batterie zur
Sprechbatterieversorgung
Abb. 13
Die verbleibende Messleitung an einer guten Ader, die mit
dem anderen Ende der zu prüfenden Ader
zusammengeschaltet ist, anschließen und auf Pieptöne
hören, die vom Prüfgerät abgegeben werden. Eine schnelle
Serie von Pieptönen zeigt Kontinuität an. Die Ergebnisse
durch abwechselndes Kurzschließen der Messleitungen
und Anschließen des
Prüfgeräts an die zu
prüfende Ader vergleichen.
Kein wahrnehmbare r
Unterschied sollte zwischen
den Pieptontakten
festgestellt werden.
Batteriebetrieb
Wenn eine Sprechbatterie-
stromquelle erforderlich ist,
den Schiebeschalter in die
„Batt“-Position bringen.
Dann Fernmeldetechniker-
Prüfgeräte oder Telefone in
Serie an der Messleitung
des Prüfgeräts anschließen.
(Siehe Abb. 6)
Widerstand prüfen
Um die relativen Widerstandspegel zwischen zwei Adern oder
zwischen einer einzelnen Ader und der Masse zu prüfen, den
Schiebeschalter in die „Widerstands“-Position bringen. Das
Prüfgerät gibt eine Serie von Pieptönen ab, wenn die
Messleitungen des Prüfgeräts kurzgeschlossen sind oder an
eine Widerstandsleitung angeschlossen werden. Das
Zeitintervall zwischen den Pieptönen verlängert sich
entsprechend, wenn der Widerstand der zu prüfenden Leitung
erhöht wird. Folglich erzeugt ein vollständiger Kurzschluss
eine schnelle Serie von Pieptönen, und das Anfassen der
Messleitungsklemmen mit jeweils einer Hand erzeugt
Pieptöne in erheblich langsamerem Takt.
Auf Kurzschlüsse prüfen
Um ein Paar von Adern auf Kurzschlüsse zu prüfen, das
Prüfgerät 600LS an das Paar anschließen. Den
Schiebeschalter in die
„Widerstands“-Position bringen
und auf „Pieptöne“ hören, die vom
Prüfgerät abgegeben werden.
Eine schnelle Serie von Pieptönen
zeigt einen vollständigen
Kurzschluss an.(Siehe Abb. 7)
Auf Erdschluss prüfen
Ein „Erdschluss“ ist einem
Kurzschluss insofern ähnlich, als
er durch ein Isolierungsversagen
zwischen zwei Adern verursacht
wird. In diesem Fall befindet sich
der Ausfall zwischen den Anlagen
und der Masse. Um eine Leitung
oder ein Paar auf „Erdschlüsse“ zu
prüfen, wie folgt verfahren: Den Schiebeschalter in die
„Widerstands“-Position bringen und auf Pieptöne hören, die
vom Prüfgerät abgegeben
werden. Eine schnelle Serie von
Pieptönen zeigt einen Weg von
geringem Widerstand zur Masse
an. (Siehe Abb. 8)
Auf Querschlüsse
prüfen
Ein Querschluss ist im Prinzip
ein Kurzschluss mit einer Ader
eines anderen Paars. Um
auf Querschlüsse in einer
gegebenen Gruppe von Paaren
zu prüfen, den Schiebeschalter
in die „Widerstands“-Position
bringen und eine Messleitung an
eine Ader des ersten Paars in der
Gruppe anschließen. Die andere Messleitung an die
verbleibenden Adern anschließen, und zwar eine nach der
anderen. Ein Querschluss ist dann angezeigt, wenn das
Prüfgerät eine Serie von Pieptönen abgibt. Als Nächstes die
erste Messleitung abwechselnd an jede Ader anschließen und
gegen die verbleibenden
Adern prüfen.(Siehe Abb. 9)
Kapazität
Die „Kap“-Position wird
eingesetzt, um die Zahl der
Rufumsetzer auf einer
Leitung zu schätzen.(Siehe
Abb. 10)
Bevor diese Prüfung
durchgeführt wird, sollte die
Leitung auf Zentralbatterie,
Kurz- und Erdschlüsse
geprüft werden. Jeder
einzelne dieser Zustände
erzeugt falsche Anzeigen.
Nachdem die Leitung (das
Paar) „freigemacht“ worden ist, die Messleitungen des
Prüfgeräts an die Leitung anschließen und den
Schiebeschalter in die „Kap“-Position bringen.
Ein Dauerton zeigt an, dass keine Rufumsetzer auf der
Leitung vorhanden sind. Ein piepsender Ton etwa einmal pro
Sekunde zeigt an, dass die Leitung von einem Rufumsetzer
abgeschlossen wird. Jeder weitere Rufumsetzer verringert
den Pieptakt um eine Sekunde, d.h.:
1 Rufumsetzer = 1
(Sekunde pro Piepton)
2 Rufumsetzer = 2
(Sekunden pro Piepton) usw.
Diese Prüfung zeigt auch die
Kapazität (im Verhältnis zur
Länge) einer Leitung an, die
nicht von einem Rufumsetzer
abgeschlossen wird. Die
Leitungslänge muss wenigstens
30 m betragen. Wenn die
Leitungslänge ungefähr 9,0 -
9,5 km beträgt, ist der Pieptakt
der Last eines einzelnen
Rufumsetzers ähnlich.
Pegel prüfen
Um den relativen Spannungspegel
auf der Leitung zu prüfen, wie folgt
verfahren: Den Schiebeschalter in
die „Pegel“-Position bringen. Die
rote Messleitung an der B-Ader der
zu prüfenden Leitung anschließen.
(Siehe Abb. 11) Die schwarze
Messleitung an der A-Ader der zu
prüfenden Leitung anschließen.
Die folgenden Zustände
überprüfen:
1. Wird kein Ton vom Prüfgerät
abgegeben, liegt die Spannung
unter 3 V Gleichstrom.
2. Wird ein Wechselton abgegeben, liegt eine Spannung
von 3-30 V Gleichstrom auf der Leitung vor, was durch
eine besetzte Leitung verursacht wird.
3. Wird ein einzelner Dauerton abgegeben, liegt eine
Spannung von 30-48 V Gleichstrom auf der Leitung vor,
was eine freie Leitung (oder Zentralbatterie) anzeigt.
4. Ein Wechselton begleitet von einem Brummen zeigt eine
Spannung von 3-30 V Wechselstrom auf der Leitung an.
5. Ein Dauerton begleitet von einem Brummen zeigt eine
Spannung von 30-48 V Wechselstrom auf der Leitung an.
Ist anzunehmen, dass sich die Leitung in gutem Zustand
befindet, diese Prüfungen aber keinen Ton erzeugen, dann ist
die Polarität u.U. umgekehrt. Die Messleitungen umkehren
und die Prüfung wiederholen.
Siehe Prüfen einer modularen Leitung hinsichtlich
zusätzlicher Prüfung der Leitungsumkehr.
Polarität prüfen
Die Polarität der ersten und zweiten Leitungen auf einem
Modularstecker kann mit Hilfe des zur Verfügung stehenden
Modularkabels und --steckers und Beobachtung der beiden
LEDs festgestellt werden. Den Dreipositionsschalter in die
Modularposition bringen.
Schalter in
Batterieposition
Abb. 6
Schalter in
Widerstandsposition
Abb. 7
Schalter in
Widerstandsposition
Abb. 8
Schalter in
Kapazitätsposition
A-Ader
B-Ader
Abb. 10
Schalter in
Widerstandsposition
Erstes
Paar
Zweites
Paar
Abb. 9
Schalter in
Pegelposition
A-Ader – Schwarze
Messleitung
B-Ader – Rote
Messleitung
Abb. 11
ACHTUNG
Vor Öffnen des Gehäuses die Messleitungen von der
Leitung entfernen und das Gerät ausschalten.
Nichtbeachten dieser Sicherheitsvorkehrungen kann
zu schweren Verletzungen oder zum Tod führen.
  • Page 1 1
  • Page 2 2

Greenlee 600LS Test Set Manuel utilisateur

Catégorie
Testeurs de réseau câblé
Taper
Manuel utilisateur