LOCATION REQUIREMENTS 15
Kiosk Installation Manual
CHAPTER 2 – INSTALLATION LOCATION REQUIREMENTS
Using the Service and Wheelchair Clearance requirements as a guide, install
the kiosk in a location with adequate space on each side.
Complete all necessary Site Surveys and review facility drawings to
ensure that no gas, water, electrical lines, etc. will be near any of holes
that will be drilled in the flooring. Kiosk location must comply with all
other applicable codes (fire escape routes, etc.). The floor must be flat
and sub-flooring material must be concrete with a minimum thickness of
4.0 in.
Before installing, obtain any necessary permits or property owner
authorizations. All work must be done in full accordance with the
requirements of all agencies and authorities having legal control; all
applicable state and city codes; Barrier Free requirements, OSHA, and the
local utility companies’ requirements.
Make sure that the appropriate electrical and network connections are
present before installation (appropriate surge suppression is
recommended). The connections should be located such that all cords will
be safely routed away from any human traffic and will not cause anyone to
trip over them. Do not modify the AC power cord supplied with the kiosk.
Do not install the unit:
In an environment where the ambient temperature exceeds 90° F.
Where it will be exposed to direct sunlight or warm air from an HVAC
system.
Within 8 feet of Electronic Article Surveillance devices that generate radio
frequency energy or magnetic fields.
WARNING
The kiosk must be connected to an individual
branch circuit that is properly grounded and
appropriately rated to the device power
requirements. For specific power
requirements, see the product label on the
back of the kiosk.