Living Earth Crafts Mystia Manuel utilisateur

Catégorie
Masseurs
Taper
Manuel utilisateur
USER MANUAL
1-400-0007 • Rev C • 5/15/17
© Living Earth Crafts 2017, All Rights Reserved
*all chairs shown with oponal accessories and/or nishes
Club Chair V2
Mystia
5th Avenue
Pedicure Chairs with
Plumbed Tubs
© Copyright 2017
Living Earth Cras®
All rights reserved. is document or any
portion thereof may not be reproduced
in any way, including photocopying or
translation to another language without
the prior written permission from Living
Earth Cras.
Living Earth Cras® is a registered trade-
mark of Earthlite Massage Tables, Inc.
Legal Notice
e information provided in this document is intended
for informational purposes only and is subject to change
without notice. e information provided in this docu-
ment should not be construed as a commitment by
Living Earth Cras®.
Living Earth Cras® assumes no responsibility for the
accuracy or suitability of the information contained in
this document. is document may contain technical
inaccuracies or errors. Living Earth Cras® makes no
expressed or implied warranties of any kind concerning
the information contained in this document, including,
but not limited to, the implied warranties of merchant-
ability and tness for purpose.
Living Earth Cras® shall not be liable for incidental or
consequential damages in connection with or arising out
of the product, performance, or use of this document
and the information and material it describes.
Introduction
Congratulaons on your purchase of the newest innovaon in nail furniture! The Club Chair V2,
Mysa, and 5th Avenue oer fresh alternaves to bulky tradional pedicure thrones. With a
small footprint of a well-appointed manicure chair, the Living Earth Cras pedicure chairs slide
smoothly back to convert into the nest pedicure system available.
The Club Chair V2, Mysa, and 5th Avenue are designed for licensed technicians and are
intended to be used in a professional spa, salon, or similar commercial environment. While no
special training is needed to operate this equipment, for safety reasons it is important that the
instrucons contained in this manual are reviewed in detail before the rst use. This manual
should be read in its enrety by each professional who will be operang the equipment to ensure
the safety of both operator and client. This manual should be saved for future reference.
The Club Chair V2, Mysa, and 5th Avenue should not be used in any other manner than described
in this manual. Please read, understand, and follow all safety warnings, labels, and instrucons.
Misuse, use of unnecessary force, or using the equipment for unintended or unauthorized
procedures can result in injury to operator, client, and/or equipment.
Detailed instrucons for use and maintenance can be found in this user manual. If you have
further quesons, please contact us at (800) 872-0560 for US customers, or (760) 597-2155 for
internaonal customers. We can also be reached via e-mail at info@livingearthcras.com.
Secon 1: Safety Informaon
Safety Symbols & Warnings - English
Safety Symbols & Warnings - French
Secon 2: Product Overview
Chair Models
Foot Spa Overview
Secon 3: Operang Instrucons
Foot Spa Instrucons
Pedicure Chair Instrucons
Relaxor® Heat/Massage
Manicure Trays
Secon 4: Care & Maintenance
Sanijet® Cleaning Instrucons
Care Instrucons
Troubleshoong
Electrical Specicaons
Secon 5: Installaon
Chair Specic Diagrams
Tub Installaon Guidelines
Electrical/Plumbing
Contact Us
2-3
4-5
6
7
8-9
10
11
12-13
14
15
16
17
18-20
21
22-25
Table of Contents
back cover
SECTION 1: SAFETY INFORMATION
Safety Symbols ALERT
Indicates a potentially hazardous
situation which could result in
equipment damage and/or injury.
Familiarize yourself with the following Safety &
Warning symbols. They are designed to prevent
damage and injury to you, your clients, and your
new Living Earth Crafts product.
DANGER
Indicates an imminently hazardous
situation which will result in serious or
fatal injury - used in extreme conditions.
WARNING
Indicates a potentially hazardous
situation which could result in serious
injury.
IMPORTANT SAFETY INSTRUCTIONS
The important safety instructions and warnings in this manual cannot cover all possible problems and condi-
tions that can occur. Use common sense and caution when installing, operating, or maintaining this equipment.
FOR COMMERCIAL USE ONLY - READ ALL INSTRUCTIONS BEFORE USE.
HYDROTHERAPY TUB - INSTALLATION INSTRUCTIONS
WARNING - When using electrical products, basic precautions should always be followed,
including the following:
2
1. DANGER: RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a ground-fault circuit-interrupter.
2. Grounding is required. The unit should be installed by a qualied service representative and grounded.
3. A licensed plumber and electrician are required to install your foot bath.
4. Check with a qualied electrician or serviceman if you are in doubt as to whether the product is connected to a
GFCI circuit and/or properly grounded. Do not modify the plug provided with the product - if it will not t the outlet,
have a proper outlet installed by a qualied electrician.
5. Always unplug this furnishing from the electrical outlet before cleaning and/or servicing.
WARNING - RISK OF HYPERTHERMIA AND POSSIBLE DROWNING. Water temperature in excess
of 100.4° (38°C) can be injurious to your health. Check and adjust water temperature before use.
WARNING - The use of alcohol, drugs, or medication can greatly increase the risk of hyperthermia. DO
NOT use drugs or alcohol before using the foot bath.
Hyperthermia ocurs when the internal temperature of the body reaches a level several degrees above the
normal body temperature of 98.6°F. THe symptoms of hyperthermia include an increase in the internal
temperature of the body, dizzines, lethargy, drowsiness, and fainting. The effects of hyperthermia include:
a) Failure to perceive heat,
b) Failure to recognize the need to exit the hydromassage tub,
c) Unawareness of impending hazard,
d) Fetal damage in pregnant women,
e) Physical inability to exit the hydromassage bathtub, and
f) Unconsciousness resulting in the danger of drowning.
To reduce the risk of electric shock, this pedicure chair has a polarized plug (one blade is wider than the
other). This plug will t in a polarized outlet only one way. If the plug does not t fully in the outlet, reverse
the plug. If it still does not t, contact a qualied electrician to install the proper outlet. Do not change the
plug in any way.
SERVICING OF DOUBLE-INSULATED PRODUCT
This pedicure chair is double insulated. In a double-insulated product, two systems of insulation are
provided instead of grounding. No grounding means is provided on a double-insulated product, no should
a means for grounding be added to the product. Servicing a double-insulated product requires extreme
car and knowledge of the system, and should be done only be done by qualied service personnel.
Replacement parts for a double-insulated product must be identical to the parts they replace. A double-
insulated product is marked with the words “DOUBLE INSULATION” or “DOUBLE INSULATED”
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
SECTION 1: SAFETY INFORMATION
WARNING - RISK OF ACCIDENTAL INJURY OR DROWNING - Children or
handicapped persons should not use foot bath without adult supervision.
2 3
WARNING - RISK OF INJURY - Exercise care when using a foot bath. Use this product for its intended
purpose: a manicure chair and ll and drain indoor commercial appliance for foot and ankle hydro
massage. DO NOT use attachments not recommended by manufacturer.
WARNING - RISK OF ELECTRIC SHOCK - Do not permit electric appliances (such as hair dryers,
lamp, telephone, radio, or television) to be within 5 ft (1.5m) of this unit.
WARNING - To reduce the risk of burns, re, electric shock, or injury to persons:
Unplug from outlet before putting on or taking off parts.
Close supervision is necessary when this furnishing is used by, or near children, invalids, or dis-
abled persons. DO NOT leave children alone or allow them to operate the controls. Keep controls
out of reach of children.
Never use this furnishing if it has a damaged cord or plug, if it is not working properly, if it has
been dropped or damaged, or dropped into water. Return the furnishing to a service center for
examination and repair.
Keep the cord away from heated surfaces.
WARNING
DO NOT reach for any electrical object that has fallen into the water. Unplug immediately.
DO NOT drop or insert anything into jet opening, or any other opening.
DO NOT operate without complete jet assembly installed or without water lled 1 inch above jets.
DO NOT overll the basin.
DO NOT stand on or in the basin, or on the foot rest.
DO NOT leave this appliance unattended when in operation.
DO NOT use outdoors.
DO NOT tamper with any user-operated controls.
Use heated surfaces carefully. May cause serious burns. Do not use over sensitive skin areas or in
the presence of poor circulation. The unattended use of heat by children or incapacitated persons
may be dangerous.
Keep children away from sliding chair-back support mechanism.
To avoid injury, exercise care when entering or exiting the chair and foot bath.
Use caution when making positioning adjustments to your chair. Always ensure the wheels are
locked into position before you or client enters or exits the chair. Keep all equipment and body parts
away from moving parts while making any adjustments.
It is important that you clean and disinfect the jets and basin after every use.
Hydrotherapy should be pleasant and comfortable. Should you or a client experience any pain or
discomfort while using the foot bath, discontinue use immediately and consult a physician.
You or your clients should consult a physician if diabetic, have poor circulation, if feet or legs are
inamed, have an open wound, or if you have questions about whether you should be using hydro
massage equipment.
Make certain that the cord and plug are maintained in good condition and are not allowed to be-
come damaged while in use. Avoid positioning the cord in the trafc lane and it is always kept out
of the way. Take this product out of service immediately if the cord or plug becomes damaged in
any way.
Do not attempt to repair. All repairs must be performed by an authorized service representative.
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
INSTALLER/OWNER BEARS ALL RESPONSIBILITIES TO COMPLY WITH STATE
AND LOCAL CODES WHEN INSTALLING THIS PRODUCT. FAILURE TO COMPLY
WITH THESE INSTRUCTIONS MAY VOID WARRANTY.
4
SECTION 1: CONSIGNES DE SÉCURITÉ
Symboles de sécurité ALERTE
Indique une situation potentiellement
dangereuse qui pourrait endommager
le matériel ou blesser un individu.
Veuillez vous familiariser avec les symboles
Sécurité & Avertissements. Ils ont été conçus
pour éviter les dommages corporels ou matériels
sur vous, vos clients et vos nouveaux produits
Living Earth Crafts.
DANGER
Indique une situation dangereuse
imminente qui causera des blessures
sérieuses, voire fatales (n’apparaît que
dans des conditions extrêmes).
Indique une situation potentiellement
dangereuse qui pourrait causer des
blessures sérieuses.
INSTRUCTIONS DE SÉCURITÉ IMPORTANTES
Les instructions de sécurité et les avertissements de ce manuel ne peuvent couvrir tous les prob-
lèmes et conditions pouvant exister. Faites preuve de bon sens et d’attention lors de l’installation,
de l’utilisation et de l’entretien de cet équipement.
À USAGE COMMERCIAL UNIQUEMENT - LISEZ TOUTES LES INSTRUCTIONS AVANT UTILI-
SATION
INSTRUCTIONS D’INSTALLATION
AVERTISSEMENT - L’utilisation de produits électroniques doit toujours être précédée de
certaines précautions de base, y compris :
LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS
CONSERVEZ CES INSTRUCTIONS
1. DANGER : RISQUE D’ÉLECTROCUTION. Connectez-vous uniquement sur un circuit protégé par
un disjoncteur de fuite à la terre.
2. Mise à la terre requise. L’unité doit être installée par un représentant de service qualié et mise à
la terre.
3. Votre bain de pied doit être installé par un plombier et un électricien agréés.
4. Si vous n’êtes pas certain que le produit soit connecté à un circuit DDFT et/ou correctement mis
à la terre, faites faire les vérications par un électricien qualié ou un technicien Ne modiez pas
la prise mâle fournie avec le produit. Si elle ne correspond pas à la prise femelle, faites installer le
branchement adapté par un électricien qualié.
5. Débranchez toujours cet équipement de la prise électrique avant son nettoyage et/ou son entretien.
AVERTISSEMENT - RISQUE D’HYPERTHERMIE ET POSSIBILITÉ DE NOYADE. Une
température de l’eau supérieure à 38 °C (100,4 °F) peut nuire à votre santé. Vériez et
ajustez la température de l’eau avant utilisation.
AVERTISSEMENT - L’utilisation d’alcool, drogue ou médicament peut grandement augmenter le
risque d’hyperthermie. N’UTILISEZ NI drogue, NI alcool avant d’utiliser le bain de pied.
Il y a hyperthermie lorsque la température interne du corps est au-dessus de la température normale
du corps (37 °C). Les symptômes de l’hyperthermie comprennent une augmentation de la température
du corps, vertiges, léthargie, somnolence et évanouissement. Les effets de l’hypothermie peuvent
inclure :
a) Inaptitude à ressentir la chaleur,
b) Inaptitude à identier le besoin de sortir du bassin d’hydromassage,
c) Inconscience d’un danger imminent,
d) Dommages au fœtus chez les femmes enceintes,
e) Incapacité physique à sortir du bassin d’hydromassage et
f) Évanouissement pouvant résulter en une noyade.
AVERTISSEMENT
L’INSTALLATEUR/PROPRIÉTAIRE EST TOTALEMENT RESPONSABLE DU RESPECT DES RÈGLES DE SON
ÉTAT ET DE SA LOCALITÉ LORS DE L’INSTALLATION DE CE PRODUIT. NE PAS SE CONFORMER À CES
INSTRUCTIONS PEUT ANNULER LA GARANTIE.
45
SECTION 1: CONSIGNES DE SÉCURITÉ
AVERTISSEMENT - RISQUE DE BLESSURE ACIDENTELLE OU DE NOYADE -
Les enfants et personnes handicapées ne doivent utiliser le bain de pied que sous la
supervision d’un adulte.
L’INSTALLATEUR/PROPRIÉTAIRE EST TOTALEMENT RESPONSABLE DU RESPECT DES RÈGLES DE SON
ÉTAT ET DE SA LOCALITÉ LORS DE L’INSTALLATION DE CE PRODUIT. NE PAS SE CONFORMER À CES
INSTRUCTIONS PEUT ANNULER LA GARANTIE.
AVERTISSEMENT - RISQUE DE BLESSURE - Soyez attentif lors de l’utilisation de ce bain de
pied. N’utilisez ce produit que pour l’usage auquel il est destiné : un fauteuil de manucure et un
appareil à utilisation commerciale et en intérieur avec arrivée et sortie d’eau pour hydromassage de
pied et cheville. N’UTILISEZ PAS d’accessoires non-recommandés par le fabricant.
AVERTISSEMENT - RISQUE D’ÉLECTROCUTION - Ne laissez pas d’appareils électriques (Ex :
sèche-cheveux, lampe, téléphone, radio, télévision) dans un rayon de 1,5 m (5 pieds) de cette
unité.
AVERTISSEMENT - Pour réduire le risque de brûlure, incendie, électrocution et blessure sur un
individu :
Débranchez la prise mâle avant d’ajouter ou de retirer des parties de l’appareil.
Une supervision attentive est nécessaire lorsque ce fauteuil est utilisé par ou près d’enfants, de
personnes invalides ou handicapées. NE LAISSEZ PAS des enfants seuls avec l’appareil et ne
les laissez pas le contrôler. Maintenez ses commandes hors de portée des enfants.
N’utilisez pas ce fauteuil si le câble ou la prise mâle est endommagé, s’il ne fonctionne pas cor-
rectement, est tombé ou a été endommagé, ou s’il est tombé dans l’eau. Renvoyez le meuble
au centre de service pour un examen et une réparation.
Maintenez le câble loin des sources de chaleur.
AVERTISSEMENT
NE CHERCHEZ PAS à récupérer un objet électrique tombé dans l’eau. Débranchez immédiate-
ment l’objet.
N’INSÉREZ rien et NE LAISSEZ rien TOMBER dans les ouvertures de jets d’eau, ni dans
aucune autre ouverture.
N’UTLISEZ PAS l’appareil s’il n’a pas été complètement installé ou si l’eau n’est pas à plus de
2,5 cm au-dessus des jets d’eau.
NE REMPLISSEZ PAS le bassin plus que nécessaire.
NE MONTEZ PAS sur ou dans le bassin, ou sur le repose-pied.
NE LAISSEZ PAS l’appareil sans surveillance pendant son utilisation.
N’UTILSEZ PAS l’appareil en extérieur.
NE MODIFIEZ PAS les commandes de l’utilisateur.
Pour éviter toute blessure, soyez attentif au moment d’entrer et de sortir du fauteuil et du bain
de pied.
Soyez attentif au moment d’ajuster la position du fauteuil. Assurez-vous toujours que les roues
sont bloquées au moment où vous ou votre client entrez ou sortez du fauteuil. Lors des ajuste-
ments, maintenez tout l’équipement et les membres du corps éloignés des parties en mouve-
ment.
Il est important de nettoyer et désinfecter les jets d’eau et le bassin après chaque utilisation.
L’hydrothérapie doit être une expérience plaisante et confortable. Si vous ou votre client ressen-
tez une douleur ou un inconfort lors de l’utilisation du bain de pied, mettez-y n immédiatement
et consultez un médecin.
Consultez un médecin si vous ou votre client êtes diabétique, avez une mauvaise circulation
sanguine, si vos pieds ou vos jambes sont enammés, si vous avez une blessure ouverte ou si
vous ignorez si vous pouvez utiliser l’équipement d’hydromassage.
Assurez-vous que le câble et la prise mâle sont en bon état et ne risquent pas d’être endom-
magés lors de l’utilisation. Évitez de placer le câble sur les voies de déplacement pour éviter
qu’il ne se trouve sur le chemin de qui que ce soit. Si le câble ou la prise est endommagé, de
quelque manière que ce soit, mettez immédiatement le produit hors service.
Ne tentez pas de le réparer. Toutes les réparations doivent être effectuées par un représentant
de service autorisé.
LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS
CONSERVEZ CES INSTRUCTIONS
Club Chair V2 Mysa 5th Avenue
Product
Image*
Chair Overall
Dimensions 49”H x 32”W x 38.5”D 45.5”H x 30.25”W x 35”D 48”H x 32”W x 36.75”D
Tub Overall
Dimensions 15.5”H x 22”W x 26.5”D 15.5”H x 22”W x 26.5”D 15.5”H x 22”W x 26.5”D
Tub Basin
DImensions 9”D x 14.75”W x 15”L 9”D x 14.75”W x 15”L 9”D x 14.75”W x 15”L
Seat Height
(from oor) 24” H 24” H 24” H
Locaon of
Tilt Lever
(Oponal)
Inside panel on the right-
hand side
Outside panel on the
right-hand side
Outside panel on the
right-hand side
Tilt Angle
(Oponal) 20 degree lt range 20 degree lt range 20 degree lt range
Cushioning Strata™ Memory Foam
Cushioning System
Strata™ Memory Foam
Cushioning System
Strata™ Memory Foam
Cushioning System
Upholstery Naturso® Naturso® Ultraleather® or Promessa®
Other
Opons
Relaxor® Heat/Massage
DIscharge Pump
Swingaway Nail Trays
Relaxor® Heat/Massage
DIscharge Pump
Swingaway Nail Trays
Relaxor® Heat/Massage
DIscharge Pump
Swingaway Nail Trays
SECTION 2 : PRODUCT OVERVIEW
*all products shown with oponal accessories and/or nishes. Measurements may vary due to natural material variaons 6
6 7
SECTION 2 : PRODUCT OVERVIEW
Plumbed Tub Overview
Footrest
Adjustment
Knob
Power Buon - Lights*
Power Buon - Jets*
Power Buon - Discharge
Pump (Oponal)
Remote Drain
Handle
Tub Basin
Water Control
Valve (Fill &
Temperature)
Drain
Light*
Jets*
Sprayer/Fill
Reexology*
*Features are on hydrotherapy tub only
SECTION 3 : OPERATING INSTRUCTIONS
Water Control Valve (Fill & Temperature)
CAUTION
There is no automac shuto with the water ll valve. You MUST turn the valve OFF
aer the tub is lled to prevent overow and/or ooding. Do not walk away from the
tub when it is lling with water. An adequate drainage system must be provided to deal
with overow water.
Sanijet® Pipeless Jets (Hydrotherapy Tub Only)
8
Down-OffUp-FillLeft-Cold Right-Hot
The water control valve is OFF when poinng DOWN. Water dispenses when you pull the valve
UP. Hot water is dispensed when the valve is turned to the RIGHT. Cold water is dispensed when
the valve is turned to the LEFT.
Pressing the On/O buon once will start the jets, and pressing the buon again will turn the
system o. Turn on the jets ONLY AFTER the tub is lled with water, and ensure you turn the
jets OFF before draining the tub.
CAUTION
Running the jets without lling the tub with water can damage or destroy the jets.
Ensure that a MINIMUM of one (1) inch of water is above the jets prior to use.
Power Buon - Jets
Chromasoothe Light (Hydrotherapy Tub Only)
Pressing the light buon once will turn the light to the default Bright White color. Press the
buon again to cycle to the next color mode, in the following order:
1. Bright White
2. Aqua Blue
3. Soothing Blue
4. Ocean Blue
5. Majesc Gold
6. Shamrock Green
7. Fiery Red
8. Chameleon Mode
9. Party Mode
To reset, turn lights o for 5 seconds and turn back on.
Lights will ash 4 mes and return to Bright White.
Power Buon -
Lights
8 9
SECTION 3 : OPERATING INSTRUCTIONS
Adjustable Locking Footrest
There are four locking posions on the footrest. It is controlled by the locking knob on the front
of the tub. Pulling the knob will free the footrest to move up or down to the desired posion.
Releasing the knob will lock it into posion.
CAUTION
Be careful of pinch points when adjusng the footrest. Always ensure the footrest is
supported unl the knob is securely locked into place.
Knob In - Locked Knob Out - Unlocked
Remote Drain Handle
Pull the handle up and back (clockwise) to close the drain when lling the tub. Push the handle
down and parallel to the oor (counterclockwise) to open the drain and empty the tub.
Push handle away from the
footrest (counterclockwise)
to open/drain
Pull handle towards foot-
rest (clockwise) to close/ll
Discharge Pump (Optional)
The discharge pump is controlled by the buon next to the remote drain handle. Before
pressing the discharge pump to empty the tub, rst open the drain with the remote drain
handle and let the water start draining toward the pump. Wait approximately 5-10 seconds for
the pump to register, then push the discharge pump buon.
Discharge Pump Buon
SECTION 3: OPERATING INSTRUCTIONS
10
Rolling the Pedicure Chair
CAUTION
Be careful of pinch points when rolling the chair back and forth.
Your pedicure chair is mounted on four (4) casters/wheels. The two (2) locking casters are
located at the rear of the chair.
These casters allow the chair to roll smoothly back and forth over the top of the staonary
pedicure tub. The locking casters only roll forward and backward, and do not swivel. Make sure
the chair lines up directly over the tub and rolls parallel to it. The chair comes equipped with
heavy duty plasc tub guards to protect both the chair and tub.
Foot
Brake
With your foot, press DOWN on
the foot brake.
Brake
Release
With your foot, push FORWARD
on the brake release.
Locking the wheel
Unlocking the wheel
Chair rolls forward &
backward over tub
Pneumatic Back Tilt (Optional)
Locate the lever on the right side of the chair (may be inside or outside the armrest depending
on model). While sing in the chair, pull the lever and lean on the back rest unl you have
reached the desired angle. Pulling the lever again and taking your weight o the back rest will
return the back rest to its original upright posion.
*generic diagram for illustraon purposes only - chair model varies
*generic diagram for illustraon purposes only - chair model varies
SECTION 3: OPERATING INSTRUCTIONS
10 11
Relaxor® Heat & Massage (Optional)
The following diagrams illustrate the ease-of-use and funconality that the Relaxor® system
provides to you and your clients.
SELECT
WA
VE
PULSE
Ultra
PWR
LO HI
1
2
3
Power
Lower Back Heat - High
Lower Back Heat - Low
Massage All Zones - Connuous
Massage All Zones - Sequenal
Massage All Zones - Short Bursts
Raise Massage Intensity
Raise Massage Speed
Upper Back Massage
Mid Back Massage
Low Back Massage
Lower Massage Intensity
Lower Massage Speed
DANGER - RISK OF ELECTRIC SHOCK
Keep hand control and all electrical components away from water.
PWR
PWR
• Massage 15 Minute Timer (Standard)
• Massage 30 Minute Timer (Hold Down Button)
• Indicates Active Button
• Indicates Normal Standby
• Indicates High Mode
• Indicates Low Mode
Green Light
Blue Light
Red Light
Orange Light
Symbol Description
SECTION 3: OPERATING INSTRUCTIONS
Swingaway Manicure Trays (Optional)
The Swingaway Manicure Trays are a convenient way to oer manicure services in your
pedicure chair. Each tray has a post at the narrow end that can be dropped into the receivers
aached to the armrests. When not in use, your chair is equipped with convenient storage
receivers towards the back of the armrests.
To Set Up:
Insert the tray post into the receiver and
push straight down to secure.
*Club Chair V2 shown for illustrave purposes - funconality is the same for all chair models 12
To Remove:
Li tray evenly with one hand placed on
either side of the receiver. Tray may get
stuck if only lied from one side.
To Store:
Insert the tray post into the storage
receiver, and push all the way in to
prevent the tray from falling out.
The manicure trays can easily be swiveled to any posion that is desired. Below are the most
commonly used tray posions and their funcons.
Posion 1: Places trays closer to the client and allows the magnec center tray to be aached.
Posion 2: Places trays closer to the technician and provides more room for the client.
Posion 3: Allows the trays to funcon as extended armrests or table.
position 1 position 2 position 3
Overhead view
Tray Positioning
SECTION 3: OPERATING INSTRUCTIONS
Magnetic Center Tray (Optional)
The Magnec Center Tray provides even more surface area for your manicure services. If
ordered, at the me of manufacturing both your Swingaway Manicure Trays and Center Tray
will be equipped with embedded magnets to hold the trays into a locked posion.
Your Magnec Center Tray is stored in a zippered compartment within the backrest. To access,
simply unzip and pull the tray out of the storage compartment. Place the center tray on the
Swingaway Manicure Trays, and move it slightly back and forth unl the magnets “catch”.
The nished conguraon will look like the photo below:
12 13
Swingaway Manicure Tray Dimensions
11.5”
23.5”
11.5”
23.5”
SECTION 4: CARE & MAINTENANCE
Tub Cleaning Guide
Cleaning After Each Use/Client
1. Drain the tub of all water.
2. Rotate the jet cover to unlock. (Fig. 1)
3. Remove the jet cover. (Fig. 2)
4. Remove the magnec impeller/rotor from the jet case. (Fig. 3)
5. Place jet cover and impeller/rotor into a sink. Use a non-abrasive anbacterial cleaner and
clean brush to remove any visible residue. Rinse with fresh water, and dry with a clean
paper towel.
6. Use a non-abrasive anbacterial cleaner and clean brush to scrub and clean the tub basin,
drain stopper, and light casing, followed by a rinse with fresh water.
7. Rell the tub with clean water and add the correct amount (read manufacturer label for
mixing instrucons) of an EPA-registered liquid disinfectant that is labeled as a bactericide,
fungicide, and virucide. Turn on the jets to circulate the water for at least 10 minutes.
8. Drain the tub, rinse with fresh water, and wipe dry with a clean paper towel.
9. Reinstall the magnec impeller/rotor.
10. Reinstall the jet cover by aligning at the 10 o’clock posion. Maintain even pressure and
rotate jet cover to lock into place at the 3 or 9 o’clock posion.
IMPORTANT: Jets will not run if not locked into place properly.
Fig. 1 Fig. 2 Fig. 3
CAUTION
- Always refer to your state and local codes for specic cleaning requirements.
- NEVER USE abrasive cleaners on any surface area. Failure to comply can cause damage
and void your warranty.
14
Foot Bath Additives
Provide an enhanced pedicure experience with essenal oils, aromatherapy, and other addives,
knowing all residue can be easily removed. The Sanijet® foot bath can be used with most foot and
skin care products, provided that the cleaning protocols and local codes are strictly followed.
Products NOT Recommended
Silicate based bath addives/scrubs - may void warranty.
High foam agents (use only low foam soluons).
Abrasive cleaners that might damage the system components, and scratch/dull the basin
surface (major scratches will require professional renishing.
To avoid discoloraon, products with petroleum disllates must not remain on surfaces.
14
SECTION 4: CARE & MAINTENANCE
Tub Cleaning Guide
Cleaning At the End of Each Day
1. Drain the tub of all water.
2. Rotate the jet cover to unlock. (Fig. 1)
3. Remove the jet cover. (Fig. 2)
4. Remove the magnec impeller/rotor from the jet case. (Fig. 3)
5. Place jet cover and impeller/rotor into a sink. Use a non-abrasive anbacterial cleaner and
clean brush to remove any visible residue. Rinse with fresh water, and dry with a clean
paper towel.
6. Use a non-abrasive anbacterial cleaner and clean brush to scrub and clean the tub basin,
drain stopper, and light casing, followed by a rinse with fresh water.
7. Fill the tub with warm water and detergent and turn on the jets to circulate water/
detergent through the spa system for at least 10 minutes.
8. Drain the detergent soluon and rinse the basin.
9. Rell the tub with clean water and add the correct amount (read manufacturer label for
mixing instrucons) of an EPA-registered liquid disinfectant that is labeled as a bactericide,
fungicide, and virucide. Turn on the jets to circulate the water for at least 10 minutes.
10. Drain the tub, rinse with fresh water, and wipe dry with a clean paper towel.
11. Reinstall the magnec impeller/rotor.
12. Reinstall the jet cover by aligning at the 10 o’clock posion. Maintain even pressure and
rotate jet cover to lock into place at the 3 or 9 o’clock posion.
IMPORTANT: Jets will not run if not locked into place properly.
Cleaning Once a Week
1. Follow steps 1-9 of the “At the End of Each Day” instrucons above.
2. DO NOT DRAIN the disinfectant soluon. Aer circulang for 10 minutes, turn o the jets
and leave the disinfectant soluon undisturbed in the tub for at least 6 hours.
3. Aer at least 6 hours, drain and rinse the tub basin with clean water.
4. Rell the tub with clean water and ush the system.
5. Wipe dry with a clean paper towel.
6. Reinstall the magnec impeller/rotor.
7. Reinstall the jet cover by aligning at the 10 o’clock posion. Maintain even pressure and
rotate jet cover to lock into place at the 3 or 9 o’clock posion.
IMPORTANT: Jets will not run if not locked into place properly.
15
SECTION 4: CARE & MAINTENANCE
CAUTION
DO NOT USE acetone, paint thinner, bleach, “Armor All” type cleaners, or industrial
cleaners. These will damage the upholstery’s protecve coang.
Do not place nail care products on the Foot Bath.
Extended exposure to chemicals can damage the basin, footrest, and/or upholstery.
Failure to comply with all cleaning instrucons can cause damage to your foot bath
and pedicure chair, and void the warranty.
DANGER: RISK OF ELECTRIC SHOCK
Always unplug this furnishing from the electrical outlet before cleaning.
Your pedicure chair is relavely maintenance free. However, to ensure your chair will connue
to funcon properly and keep its appearance, we recommend the following:
Category Care Recommendation
Upholstery
Remove day-to-day dirt and smudges with a mild soap and water soluon.
For tough stains and to disinfect, use a (100 to 1) water to bleach soluon.
Spray a damp cloth with the soluon to clean.
Aer each cleaning, gently wipe the upholstery with a damp cloth and clean
water, then allow upholstery to air dry before using or storing.
For more dicult stains, please contact your dealer or please call us directly
for guidance. For best results, use only the products suggested above.
Laminate
Never use abrasive cleaners. A mild liquid detergent and warm water will
clean soiled surfaces. To avoid discoloraon, cleaners containing petroleum
disllates must not remain on surfaces.
Wood To maintain the wood nish and retouch scratches, use a high quality
furniture wax.
Electronics An-stac electronic aerosol dusters can be used to keep the surfaces of
electronic components, power cables, and plugs free of dust.
Lubricaon &
Mechanical
If necessary, lubricate wheel joints, casters, and other mechanical parts with
a light machine oil. Periodically check and ensure all visible bolts remain
ghtened.
Pedicure Chair Cleaning & Ongoing Maintenance
16
SECTION 4: CARE & MAINTENANCE
16
SECTION 4: CARE & MAINTENANCE
17
This helpful troubleshoong guide will provide you with informaon about how to recognize a
problem with your product, determine possible causes, and nd a soluon.
In the event your specic situaon is not covered in this guide, please contact Living Earth Cras
so our technical support department can assist you. Beyond the troubleshoong guide below, do
not aempt to repair the issue yourself. This can void your warranty.
Unauthorized service will not be covered. Please be sure to contact Living Earth Cras Customer
Service rst at (800) 358-8292, (760) 597-2155 Int’l.
Troubleshooting
Issue Solution
No Power to
Relaxor/Relaxor
Not Operang
1. Ensure the power cord is properly plugged into an operaonal
grounded power supply/outlet.
2. Check GFCI reset and circuit breakers or fuses.
3. Ensure the outlet in your room is receiving power. This can be done
by plugging in a small appliance and turning it on.
No Power to
Jets/Jets not
Operang
1. Ensure the power cord is properly plugged into an operaonal GFCI
power supply/outlet.
2. Check GFCI reset and circuit breakers or fuses.
3. Check jets are locked into the 9’oclock or 3 o’clock “run” posion.
4. Ensure magnec rotor/impeller is correctly installed in the case.
5. Reset the motors by unplugging the system, waing 5 seconds, then
plugging in again.
Excessive Noise
from Jets
1. Remove jet assembly and inspect for dirt buildup, debris, or damage.
2. Follow cleaning instrucons or replace if necessary.
Water Leakage
1. Check and ensure all visible bolts are ghtened.
2. Call a plumber to determine the source of the leak.
3. If the leak is from the jet system, contact LEC customer service.
SECTION 4: CARE & MAINTENANCE
18
Electrical Specications
Spec North America Europe/Asia
Input Voltage 120 VAC 220 VAC
Input Frequency 60 Hz 50 Hz
Total Consumpon - All
Opons 8.5 Amps Max 4.6 Amps Max
Consumpon - Chair &
Hydrotherapy Tub Only 4 Amps Max 2.2 Amps Max
Consumpon - Relaxor Addional 3 Amps (Max) Addional 1.6 Amps (Max)
Consumpon - Discharge
Pump Addional 1.5 Amps (Max) Addional 0.8 Amps (Max)
Motor Design Single speed, electronic spherical DC motor with magnec
rotor impeller
Motor Materials Thermoplasc jet, motor, and case assembly; stainless steel
rotor impeller
Motor Safety Features Safety shuto sensor, dry-run/thermal overload protecon
Supply Connecons 1/2” NPT (Recommended) / 1.27 cm
Drain Outlet 1.5” / 3.81 cm
Warranty Information
Living Earth Cras (LEC) oers an industry best one (1) year warranty, worldwide, on all
Pedicure Chairs and accessories. Foam and upholstery covering are warranted for three (3)
years. Hydraulic systems, motors, controls, and actuators are warranted for two (2) years,
including parts and labor. Accessories and opons are warranted for one (1) year, unless
otherwise noted. LED may repair or replace defecve components at our discreon. LEC will
return the warranted product, standard shipping pre-paid, to customers in the connental
US. Internaonal customers are responsible for any applicable dues and taxes, as well as all
shipping charges inbound and outbound. Normal wear and tear, and costs associated with
maintenance procedures, and damage caused by accident, misuse, improper maintenance,
harsh operang environments or neglect (which includes tears in the upholstery and damage
caused by harsh chemical-based cleaners) are not covered under this warranty. All warranes
are limited to repair or replacement, at LECs discreon, unless otherwise stated.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31

Living Earth Crafts Mystia Manuel utilisateur

Catégorie
Masseurs
Taper
Manuel utilisateur

dans d''autres langues