Extron MTP T 15HD A D Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

User Guide
MTP T 15HD A
Twisted Pair
Architectural Twisted Pair Transmitters
MTP T 15HD WM,
MTP T 15HD A D,
MTP T 15HD A AAP
68-2207-01 Rev. E
01 19
Safety Instructions
Safety Instructions • English
WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within
the product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind und
die einen elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in
der im Lieferumfang enthaltenen Dokumentation besonders wichtige
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad
de Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du
produit d’une tension électrique dangereuse susceptible de provoquer
un choc électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf.
68-290-01, sur le site Extron, www.extron.com.
Istruzioni di sicurezza • Italiano
AVVISO: Questo simbolo, ,quando viene utilizzato il prodotto, serve
ad avvisare l’utente della presenza di tensioni pericolose non isolate
all’interno del prodotto, che può presentare un rischio di scosse
elettriche.
ATTENTZIONE: Questo simbolo, , quando viene utilizzato il
prodotto, serve ad avvisare l’utente di importanti istruzioni di uso e
manutenzione (assistenza) nella letteratura fornita con l’apparecchiatura.
Per informazioni sulle linee guida di sicurezza, adempimenti normativi,
compatibilità EMI/EMF, accessibilità e argomenti correlati, vedere la sicurezza
di Extron e Regulatory Compliance Guide, parte numero
68-290-01, sul sito Web Extron, www.extron.com.
Instrukcje bezpieczeństwa • Polska
OSTRZEŻENIE: Ten symbol, , gdy używany na produkt, ma na celu
poinformować użytkownika o obecności izolowanego i niebezpiecznego
napięcia wewnątrz obudowy produktu, który może stanowić zagrenie
porażenia prądem elektrycznym.
UWAGI: Ten symbol, , gdy używany na produkt, jest przeznaczony do
ostrzegania użytkownika ważne operacyjne oraz instrukcje konserwacji
(obsługi) w literaturze, wyposażone w sprzęt.
Informacji na temat wytycznych w sprawie bezpieczeństwa, regulacji
wzajemnej zgodności, zgodność EMI/EMF, dostępności i Tematy pokrewne,
zobacz Extron bezpieczeństwa i regulacyjnego zgodności przewodnik, część
numer 68-290-01, na stronie internetowej Extron, www.extron.com.
Инструкция по технике безопасности Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии неизолированного опасного напряжения
внутри корпуса продукта, которое может привести к поражению электрическим
током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: ,
www.extron.com, номер по каталогу - 68-290-01.
安全说明 简体中文
警告 产品上的这个标志意在警告用户该产品机壳内有暴露的危险 电压,
险。
注意 产品上的这个标志意在提示用户设备随附的用户手册中有
重要的操作和维护(维修说明。
关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍
使用的特性等相关内容,敬请访问 Extron 网站 , www.extron.com,参见
Extron 安全规范指南,产品编号 68-290-01
安全記事 • 繁體中文
警告: 若產品上使用此號,是為了提醒使用者產品機殼內存在著
可能會導致觸電之風險的未絕緣危險電壓
注意 品上使用此符號,是為提醒使用設備隨附戶手冊中
重要的操作和維(維修説明
有關安全性指導方針法規遵EMI/EMF 相容取範圍和相主題的詳細
訊,請瀏覽 Extron 網站:www.extron.com然後參閱《Extron 安全性與法規
守手冊則編號 68-290-01
安全上の注意
日本語
警告: この 製品上に表示されている場合は、筐体内に絶縁され
いない高電圧が流れ、電の危険があるを示ていま
意:この が製上に表示されている場合は、の取明書に
されている重作と保()のについてユーザー
を喚起するものです
安全上の注意、法規厳守、EMI/EMF適合性、その他の関連項
スト イト www.extron.com よ り Extron Safety
and Regulatory Compliance Guide』 ( P/N 68-290-01) をご覧ださい。
안전 지침 • 한국어
경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합
니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에
대한 자세한 내용은 Extron 웹 사이트(www.extron.
com)의 Extron 안전 및 규제 준수 안내서, 68-290-01 조항을 참조하십시오.
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause interference. This interference must be corrected at the expense of the user.
ATTENTION: The Twisted Pair Extension technology works with shielded twisted pair
(STP) cables only. To ensure FCC Class A and CE compliance, STP cables and STP
connectors are also required.
For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the “Extron Safety and Regulatory
Compliance Guide” on the Extron website.
Copyright
© 2017
-2019 Extron Electronics. All rights reserved.
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks
®
, registered service marks
(SM)
, and trademarks
(TM)
are the property of RGB Systems, Inc. or
Extron Electronics (see the current list of trademarks on the Terms of Use page at www.extron.com):
Registered Trademarks
(®)
AVTrac, Cable Cubby, ControlScript, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, Extron, Flat Field, FlexOS, Global Configurator,
GlobalScripter, GlobalViewer, Hideaway, Inline, IPIntercom, IPLink, KeyMinder, LinkLicense, LockIt, MediaLink, MediaPort, NetPA,
PlenumVault, PoleVault, PowerCage, PURE3, Quantum, SoundField, SpeedMount, SpeedSwitch, SystemINTEGRATOR, TeamWork, TouchLink,
V-Lock, VersaTools, VN-Matrix, VoiceLift, WallVault, WindoWall, XTP, and XTPSystems
Registered Service Mark
(SM)
: S3 Service Support Solutions
Trademarks
(
)
AAP, AFL (Accu-RateFrameLock), ADSP(Advanced Digital Sync Processing), Auto-Image, CableCover, CDRS(ClassD Ripple Suppression),
DDSP(Digital Display Sync Processing), DMI (DynamicMotionInterpolation), DriverConfigurator, DSPConfigurator, DSVP(Digital
Sync Validation Processing), eLink, EQIP, EverLast, FastBite, FOX, FOXBOX, HyperLane, IP Intercom HelpDesk, MAAP, MicroDigital,
Opti-Torque, ProDSP, QS-FPC(QuickSwitch Front Panel Controller), Room Agent, Scope-Trigger, ShareLink, Show Me, SIS,
SimpleInstructionSet, Skew-Free, SpeedNav, Triple-Action Switching, True4K, Vector™ 4K , WebShare, XTRA, ZipCaddy, and ZipClip
Conventions Used in this Guide
Notifications
The following notifications are used in this guide:
CAUTION: Risk of minor personal injury.
ATTENTION : Risque de blessuremineure.
ATTENTION:
Risk of property damage.
Risque de dommages matériels.
NOTE: A note draws attention to important information.
Specifications Availability
Product specifications are available on the Extron website, www.extron.com.
viMTP T 15HD A Architectural Series • Contents
Contents
Introduction ................................................... 1
About this Guide ................................................. 1
About the MTP Transmitters ............................... 1
Twisted Pair Cable Advantages ....................... 1
Transmission Distance .................................... 1
About the MTP T 15HD A WM ........................ 3
About the MTP T 15HD A D ........................... 4
About the MTP T 15HD A AAP ....................... 4
Installation ..................................................... 5
Installing the MTP T 15HD A WM and
MTP T 15HD A D .............................................. 5
Preparing the Site and Installing the
Wall Box ........................................................ 5
Installing into a Mud Ring (WM and Decorator-
Style Models) ................................................. 6
Final Installation .............................................. 7
Installing the MTP T 15HD A AAP ....................... 8
Connections and Settings................................... 9
Front Panel Features ....................................... 9
Rear Panel Features ..................................... 10
Power Supply Wiring and Grounding ................ 11
Twisted Pair Cable Termination ......................... 14
EDID Minder Configuration ............................... 15
Reference Information ............................... 16
Decorator-Style Wallplate Template
Dimensions .................................................. 16
MTP T 15HD A Architectural Series • Introduction 1
Introduction
This section gives an overview of the user guide. This section also describes the
MTP 15HD A Architectural Series of transmitters. Topics that are covered include:
About this Guide
About the MTP Transmitters
About this Guide
This guide contains installation, configuration, and operation information for the
Extron MTP 15HD A Architectural Series of transmitters.
About the MTP Transmitters
The Extron MTP T 15HD A Architectural Twisted Pair Transmitters (available in either black or
white) are a series of wall, Architectural Adapter Plate (AAP) or furniture mounting products
that are based on the MTP T 15HD A Twisted Pair Transmitter.
The Extron MTP T 15HD A architectural transmitters accept high resolution computer-video
on a female 15-pin HD connector and a stereo audio signal on a female 3.5 mm mini stereo
jack. The female RJ-45 output connector, mounted on a 3 inch pigtail, transmits a computer
video and summed mono audio signal to an MTP R 15HD A, MTP RL 15HD A, or
MTP RL 15HD A SEQ receiver. A pre-peaking control switch boosts the transmission
distance of the proprietary signal.
The MTP T 15HD A architectural series is part of a system for long-distance distribution of
VGA or other high resolution video and audio, over Extron Enhanced Skew-Free AV UTP
Cable, or any CAT 5, 5e, or 6 shielded twisted pair (STP), unshielded twisted pair (UTP), or
foil shielded twisted pair (FTP) cable.
Twisted Pair Cable Advantages
Twisted pair cable is smaller, lighter, more flexible, and less expensive than coaxial cable.
Termination of the cable with RJ-45 connectors is simple, quick, and economical (see
Twisted Pair Cable Termination on page 14 for wiring details).
Transmission Distance
The maximum distance is determined by the frequency and resolution of the signal that is
input to the transmitter.
See figure 1 on the following page for the recommended maximum transmission distances
and transmitter Pre-Peak switch positions using Extron Enhanced Skew-Free AV UTP cable
or UTP CAT 5 cable, terminated with CAT 5 rated connectors.
MTP T 15HD A Architectural Series • Introduction 2
Video
Format
Pre-Peak
off
Pre-Peak
on
Max. Distance
(High Quality)
Max. Distance
(Variable Quality)
Composite,
S-video,
Component
800'
(245 m)
1000'
(300 m)
640x480
<300'
(90 m)
>350'
(105 m)
700'
(215 m)
750'
(240 m)
800x600
<300'
(90 m)
>350'
(105 m)
550'
(165 m)
650'
(200 m)
1024x768*
<300'
(90 m)
>350'
(105 m)
500'
(150 m)
600'
(185 m)
1280x960*
<300'
(90 m)
>350'
(105 m)
400'
(120 m)
500'
(150 m)
1280x1024*
<250'
(75 m)
>300'
(90 m)
350'
(105 m)
450'
(135 m)
1360x765
<250'
(75 m)
>300'
(90 m)
400'
(120 m)
500'
(150 m)
1365x768
<250'
(75 m)
>300'
(90 m)
400'
(120 m)
450'
(135 m)
1366x768
<250'
(75 m)
>300'
(90 m)
400'
(120 m)
450'
(135 m)
1400x1050
<250'
(75 m)
>300'
(90 m)
350'
(105 m)
400'
(120 m)
1440x900
<250'
(75 m)
>300'
(90 m)
350'
(105 m)
400'
(120 m)
1600x1200*
<250'
(75 m)
>300'
(90 m)
300'
(90 m)
450'
(135 m)
1920x1200
<250'
(75 m)
>300'
(90 m)
300'
(90 m)
400'
(120 m)
2048x1080
<250'
(75 m)
>300'
(90 m)
300'
(90 m)
400'
(120 m)
HDTV 720p
<250'
(75 m)
>300'
(90 m)
400'
(120 m)
500'
(150 m)
HDTV 1080i
<250'
(75 m)
>300'
(90 m)
300'
(90 m)
400'
(120 m)
HDTV 1080p
<250'
(75 m)
>300'
(90 m)
300'
(90 m)
400'
(120 m)
Figure 1. Recommended Pre-Peak Switch Positions and Transmission Distances
at 60 Hz
NOTES:
Resolutions marked with an asterisk (*) in the table above have the same range
specifications at 75 Hz.
It is possible to exceed the recommended distance, but image quality may be
reduced.
MTP T 15HD A Architectural Series • Introduction 3
NOTES:
The transmitters are for use with, and perform best with Extron Enhanced
Skew-Free AV cable terminated in accordance with the TIA/EIA T 568 A
wiring standard. CAT 5 cables are acceptable but less preferable. Extron also
recommend the use of pre-terminated and tested cables. Cables terminated
on site should be tested before use to ensure that they comply with Category 5
specifications.
The recommendations shown in the table on the previous page apply for a single
transmitter connected to a MTP receiver and for a daisy chain. For example, the
maximum suggested range for 1024 x 768 video is 300 feet (90 m) with
Pre-Peak off and 500 feet (150 m) with Pre-Peak on whether the system consists
of one transmitter and one receiver or a transmitter and three daisy-chained
receivers.
About the MTP T 15HD A WM
The MTP T 15HD A WM Twisted Pair Transmitter is a wall or furniture mountable version of
the MTP T 15HD A, and can be mounted into any standard Underwriters Laboratories (UL)
listed one-gang electrical wall box or by using the included mud ring.
AUDIO IN
MTP T 15HD A
COMPUTER IN
Figure 2. MTP T 15HD A WM Face
MTP T 15HD A Architectural Series • Introduction 4
About the MTP T 15HD A D
The MTP T 15HD A D Twisted Pair Transmitter is a wall or furniture mountable version of the
MTP T 15HD A that fits any decorator-style wallplate.
COMPUTER IN
AUDIO IN
Figure 3. MTP T 15HD A D Face
About the MTP T 15HD A AAP
The MTP T 15HD A AAP Twisted Pair Transmitter can be mounted in any Extron product
that accepts a double space AAP, such as the AAP 102.
AUDIO IN
MTP T 15HD A
COMPUTER
IN
Figure 4. MTP T 15HD A AAP Face
MTP T 15HD A Architectural Series • Installation 5
Installation
This section provides information on:
Installing the MTP T 15HD A WM and MTP T 15HD A D
Installing the MTP T 15HD A AAP
Connections and Settings
Power Supply Wiring and Grounding
Twisted Pair Cable Termination
EDID Minder Configuration
Installing the MTP T 15HD A WM and MTP T 15HD A D
The MTP T 15HD A WM and MTP T 15HD A D can be installed in a one-gang electrical
wall box, with the MTP T 15HD A D fitting into a decorator-style wallplate cover (supplied).
If a suitable wall box is already installed, follow steps 5 through 8 on the following page. To
install a new wall box or to install using the included mud ring, follow all the steps below.
UL-listed wall boxes are recommended.
The installation must conform to national and local electrical codes and to the size
requirements of the wall plate.
The following UL requirements pertain to the installation of the MTP T 15HD A architectural
series into a wall or furniture.
These units are not to be connected to a centralized DC power source or used beyond
their rated voltage range.
These units must be installed in UL-listed junction boxes.
These units must be installed with conduit in accordance with the National Electrical
Code.
Preparing the Site and Installing the Wall Box
Choose a location that allows cable runs without interference. Allow enough depth for
both the wall box and the cables. The box should be at least 2.5 inches (6.4 cm) deep
to accommodate the connectors and cables. Install the cables into the wall, furniture, or
conduits before installing the wall plate.
1. If a wall box is not available to use for a template, use the dimensions from the template
on page 16 or download a full size template online at www.extron.com.
If installing directly into furniture, cut out the center portion of the template.
2. Place the template (or the wall box) against the installation surface, and mark the
guidelines for the opening.
3. Cut out the material from the marked area.
4. Insert the wall box into the opening. The box or the rear connectors of the wall plate
should fit easily into the opening. Enlarge or smooth the edges of the opening as
needed.
MTP T 15HD A Architectural Series • Installation
6
5. With the power supply disconnected, feed cables for the output devices through the
opening and through the wall box punch-out holes, securing them with cable clamps to
provide strain relief.
6. Trim back, insulate, or do both to exposed cable shields with heat shrink to reduce the
chance of short circuits.
a. To prevent short circuits, the outer foil shield can be cut back to the point where the
cable exits the cable clamp.
b. Both braided and foil shields should be connected to an equipment ground at the
other end of the cable.
7. Connect the output device cables to the rear of the MTP architectural wall plate (see
Twisted Pair Cable Termination on page 14 for connector wiring details).
8. Connect input devices (see Front Panel Features on page 9 for connector details),
restore the power supply, and test the wall plate. Make any cabling adjustments before
final installation as the cables will be inaccessible afterwards.
Installing into a Mud Ring (WM and Decorator-Style Models)
1. Using the mud ring as a guide, mark the edges and cut out the material within the
marked area.
2. Insert the mud ring into the opening, rotate the arms, and secure with the supplied
screws.
3. Follow steps 5 through 8 of Preparing the Site and Installing the Wall Box above,
and Final Installation on page 7.
MTP 15HD A WM
PC INPUT
AUDIO
MTP T 15HD A WM
Wall
Wall Mounting
Bracket (mud ring)
Figure 5. Mounting the MTP T 15HD A WM Using the Mud Ring
MTP T 15HD A Architectural Series • Installation
7
Final Installation
After testing and making any adjustments, turn off the power supply and carefully insert the
wall box or mud ring into the opening.
Attach it with nails or screws, leaving the front edge flush with the outer wall or furniture
surface (see figure 6).
NOTES:
If attaching the wall box to wood, use four #8 or #10 screws or 10-penny nails. A
minimum of 0.5 inches (1.3 cm) of screw thread must penetrate the wood.
If attaching the wall box to metal studs or furniture, use four #8 or #10
self-tapping sheet metal screws or machine bolts with matching nuts.
Installation
Cab
le
Cable
Clamp
Wall Stud
Screws
or Nails
Wall Stud
Installation
Cable
Cable
Clamp
Screws
or Nails
Figure 6. Installing the Wall Box
If installing an MTP T 15HD A WM, mount the faceplate directly to the box or mud ring.
If installing an MTP T 15HD A D, mount it directly to the wall box, then attach the
decorator-style wall plate, as shown in figure 7, and restore the power supply.
PC INPUT
AUDIO
Wall opening
is flush with
edge of box.
Wall Box
Decorator-Style
Faceplate
MTP T 15HD A D
Figure 7. Mounting the MTP T 15HD A D
MTP T 15HD A Architectural Series • Installation
8
Installing the MTP T 15HD A AAP
The MTP T 15HD A AAP must be attached to a device faceplate or AAP wall plate and
cabled before the device or wall plate is pretested or installed in a wall or furniture.
1. Before attaching any cables, insert the standoffs of the MTP T 15HD A AAP through the
holes in the faceplate or AAP wall plate of the device.
2. Using the provided #4-40 nuts and captive washers, secure the AAP to the faceplate or
wall plate.
3. Repeat steps 1 and 2 to mount any other AAPs. Cover any openings in the faceplate
with blank plates (provided with the AAP faceplate).
4. Be sure to include the AAP connectors as part of the installation pretest before final
installation of the faceplate.
5. For more detailed installation information, see the installation guide shipped with the
device or AAP faceplate.
MTP T 15HD A AAP
AAP 102
AAP 102
AUDIO IN
MTP T 15HD A
COMPUTER
IN
Figure 8. Mounting the MTP T 15HD A AAP
MTP T 15HD A Architectural Series • Installation
9
Connections and Settings
ATTENTION:
Do not connect this device to a telecommunications or computer data
network.
Ne connectez pas cet appareil à un réseau de télécommunications ou de
données informatiques.
Front Panel Features
The front panel features are the same on all the MTP T 15HD A architectural models, as
shown in figure 9.
AUDIO IN
MTP T 15HD A
COMPUTER IN
MTP T 15HD A D
MTP T 15HD A WM
AUDIO IN
MTP T 15HD A
COMPUTER
IN
MTP T 15HD A AAP
COMPUTER IN
AUDIO IN
1
2
3
1
2
3
12 3
Figure 9. Architectural Series Front Panel Features
1 Power LED — Indicates power is applied to the MTP.
2 Audio input connector — Connect a 3.5 mm stereo audio
plug into this jack for unbalanced audio input. Wire the plug as
shown in the figure to the right.
NOTE: The figure above shows a typical audio connector, which consists of the tip,
ring, and sleeve. The tip, ring, and sleeve wires are also shown on the captive
screw audio connector diagram (see figure 11 on page 10).
3 Video input connector — Connect a computer video source to this
15-pin HD connector for high resolution video input.
NOTES:
Input only sync signals (no video signals) on the sync pins (13 and 14).
For component video, use the R (R-Y) and R return pins (pins 1 and 6),
G (Y) and G return pins (pins 2 and 7), and B (B-Y) and B return pins
(pins 3 and 8).
For S-video, use the R, R return (C-chroma), G, and G return (Y-luma) pins.
For composite video, use the G pin and the associated return pin. For
additional genlocked video signals, use the R, B, and associated return pins.
Sleeve ( )
Ring (R)
Tip (L)
51
15 11
610
Female
MTP T 15HD A Architectural Series • Installation
10
Rear Panel Features
With the exceptions of 4
,
5
,
and 6
on the MTP T 15HD A D
,
as noted in the figures and
descriptions, the rear panel features are the same on all the MTP T 15HD A architectural
models.
50ON
OFF 60
Hz
PRE-
PEAK
EDID
SELECT
1
1
3
2
6
2
3
4
5
6
Figure 10. MTP T 15HD WM and AAP (Left) and MTP T 15HD A D (Right)
Rear Panel Features
1 Output connector — Connect one end of a twisted pair cable to this RJ-45 female
connector on the transmitter. Connect the opposite end of the cable to the RJ-45
connector of the receiver (see Twisted Pair Cable Termination on page 14 to wire the
RJ-45 connectors).
2 Pre-Peak switch — The Pre-Peak DIP switch boosts the video signal output to correct
for long cable runs (see the table on page 2 for suggested switch settings based on the
transmitted video format and transmission distance).
3 Stereo Audio output connector — Insert bare wires into this direct insertion 3.5 mm,
5-pole captive screw audio connector for stereo audio outputs. Wire the connector as
shown in figure 11.
Do not tin the wires!
Balanced Audio Output
Tip
Ring
Tip
Ring
Sleeves
Unbalanced Audio Output
Tip
No Ground Here
No Ground Here
Tip
Sleeves
LR
LR
ATTENTION:
Potential damage to property.
For unbalanced audio, connect the sleeves
to the center contact ground.
DO NOT connect the sleeves to the
negative (-) contacts.
Pour l’audio asymétrique, connectez les
manchons au contact au sol. Ne PAS connecter
les manchons aux contacts négatifs (–).
Figure 11. Captive Screw Audio Connector Wiring
MTP T 15HD A Architectural Series • Installation
11
4 Frequency Select switch — The Frequency select DIP switch sets the vertical
frequency of the factory-installed EDID. 50 Hz or 60 Hz can be selected.
5 EDID Select rotary switch — This 16 position rotary switch is used to select which
factory-installed EDID information will be used. Position 0 is not used. Positions 1
through F correspond to the EDID information in the table in figure 15 on page 15.
6 Power connector — Connect the cables from the included external 12VDC power
supply to the rear panel 3.5 mm, 2-pole captive screw connector (see figures 12 and 13
below and on the next page for wiring and grounding instructions).
To verify the polarity before connection, plug in the power supply with no load and
check the output with a voltmeter.
Power Supply Wiring and Grounding
Figure 12 shows how to wire the power connector. Figure 13 on the following page shows
how to ground the unit through the power connector.
ATTENTION:
Power supply voltage polarity is critical. Incorrect voltage polarity can damage the
power supply and the unit. The ridges on the side of the cord identify the power
cord negative lead.
La polarité de la source d’alimentation est primordiale. Une polarité incorrecte
pourrait endommager la source d’alimentation et l’unité. Les stries sur le côté du
cordon permettent de repérer le pôle négatif du cordon d’alimentation.
To verify the polarity before connection, plug in the power supply with no load and check the
output with a voltmeter.
Power Supply
Output Cord
Captive Screw
Connector
3/16(5 mm)
MAX
SECTION A–A
Ridges
Smooth
AA
Power Supply
Output Cord
Captive
Screw
Connector
SECTION A–A
Ridges
Smooth
AA
3/16(5 mm)
MAX
Figure 12. Power Connector Wiring for the MTP T 15HD WM and AAP (Left), and
the MTP T 15HD A D (Right)
MTP T 15HD A Architectural Series • Installation
12
Extron twisted pair products can be adversely affected by electrostatic discharge (ESD) if
they are not grounded correctly. To prevent malfunctions or product damage, an installer
can correctly ground an Extron twisted pair product by following the diagram in figure 13 on
the next page.
Ground the power port by inserting one end of the grounding wire to the negative or ground
pin on the power input connector.
Power Supply
Output Cord
SECTION A–A
Ridges
Smooth
AA
Tie
Wrap
Rear
Panel
Ridges
Earth
Gr
ound
3/16"
(5 mm)
Max.
POWER
12V
0.5A MAX
Figure 13. Power Connector Wiring and Grounding
CAUTION: The wires must be kept separate while the power supply is plugged in.
Remove power before wiring.
ATTENTION : Les deux cordons d’alimentation doivent être tenus à l’écart l’un de
l’autre quand l’alimentation est branchée. Couper l’alimentation avant de faire
l’installation électrique.
NOTES:
Your transmitter and receiver pair may have shipped with a blue captive screw
connector. This blue connector can be plugged into either a blue or an orange
power receptacle. The blue connector does not have the extended tail or the
included tie-wrap.
Do not tin the power supply leads before installing in the direct insertion connector.
Tinned wires are not as secure in the connectors and could be pulled out of the
connector.
MTP T 15HD A Architectural Series • Installation
13
ATTENTION:
Always use a power supply supplied and or specified by Extron. Use of an
unauthorized power supply voids all regulatory compliance certification and may
cause damage to the supply and the end product.
Utilisez toujours une source d’alimentation fournie ou recommandée par Extron.
L’utilisation d’une source d’alimentation non autorisée annule toute conformité
réglementaire et peut endommager la source d’alimentation ainsi que le produit
final.
If not provided with a power supply, this product is intended to be supplied by a
power source marked “Class 2” or “LPS” and rated at 12 VDC and a minimum of
1.0 A.
Si ce produit ne dispose pas de sa propre source d’alimentation électrique, il doit
être alimenté par une source d’alimentation de classe 2 ou LPS et paramétré à 12
V et 2.0 A minimum.
The installation must always be in accordance with the applicable provisions of
National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical
Code part 1, section 16. The power supply shall not be permanently fixed to
building structure or similar structure.
Cette installation doit toujours être en accord avec les mesures qui s’applique
au National Electrical Code ANSI/NFPA70, article725, et au Canadian Electrical
Code, partie1, section16. La source d’alimentation ne devra pas être fixée de
façon permanente à une structure de bâtiment ou à une structure similaire.
Power supply voltage polarity is critical. Incorrect voltage polarity can damage
the power supply and the unit. The ridges on the side of the cord (see figure 7 on
previous page) identify the power cord negative lead.
La polarité de la source d’alimentation est primordiale. Une polarité incorrecte
pourrait endommager la source d’alimentation et l’unité. Les stries sur le côté du
cordon permettent de repérer le pôle négatif du cordon d’alimentation.
To verify the polarity before connection, plug in the power supply with no load and
check the output with a voltmeter.
Pour vérifier la polarité avant la connexion, brancher l’alimentation hors charge et
mesurer sa sortie avec un voltmètre.
The length of the exposed (stripped) copper wires is important.
The ideal length is 3/16 inch (5 mm). Longer bare wires can short together.
Shorter wires are not as secure in the connectors and could be pulled out.
La longueur des câbles exposés est primordiale lorsque l’on entreprend de les
dénuder. La longueur idéale est de 5mm (3/16inches). S’ils sont un peu plus
longs, les câbles exposés pourraient se toucher et provoquer un court circuit. S’ils
sont un peu plus courts, ils pourraient sortir, même s’ils sont attachés par les vis
captives.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air
handling spaces or in wall cavities.
Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une
utilisation dans les espaces d’aération ou dans les cavités murales.
Use the supplied tie wrap to strap the power cord to the extended tail of the connector.
As an alternative, an Extron PS 124 Universal 12 VDC Power Supply can power multiple
MTPs or other Extron 12 VDC devices using only one AC power connector.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Extron MTP T 15HD A D Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues