Extron MTP 1500RL 15HD A SEQ Manuel utilisateur

Catégorie
Glacières
Taper
Manuel utilisateur
User Guide
MTP 1500RL 15HD A and
MTP 1500RL 15HD A SEQ
MTP - Twisted Pair Series
Extended Distance Mini Twisted Pair Receivers
68-1554-01 Rev. D
01 19
Safety Instructions
Safety Instructions • English
WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within
the product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind und
die einen elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in
der im Lieferumfang enthaltenen Dokumentation besonders wichtige
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad
de Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du
produit d’une tension électrique dangereuse susceptible de provoquer
un choc électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf.
68-290-01, sur le site Extron, www.extron.com.
Istruzioni di sicurezza • Italiano
AVVERTENZA: Il simbolo, , se usato sul prodotto, serve ad
avvertire l’utente della presenza di tensione non isolata pericolosa
all’interno del contenitore del prodotto che può costituire un rischio di
scosse elettriche.
ATTENTZIONE: Il simbolo, , se usato sul prodotto, serve ad
avvertire l’utente della presenza di importanti istruzioni di funzionamento
e manutenzione nella documentazione fornita con l’apparecchio.
Per informazioni su parametri di sicurezza, conformità alle normative,
compatibilità EMI/EMF, accessibilità e argomenti simili, fare riferimento
alla Guida alla conformità normativa e di sicurezza di Extron, cod. articolo
68-290-01, sul sito web di Extron, www.extron.com.
Instrukcje bezpieczeństwa • Polska
OSTRZEŻENIE: Ten symbol, , gdy używany na produkt, ma na celu
poinformować użytkownika o obecności izolowanego i niebezpiecznego
napięcia wewnątrz obudowy produktu, który może stanowić zagrożenie
porażenia prądem elektrycznym.
UWAGI: Ten symbol, , gdy używany na produkt, jest przeznaczony do
ostrzegania użytkownika ważne operacyjne oraz instrukcje konserwacji
(obsługi) w literaturze, wyposażone w sprzęt.
Informacji na temat wytycznych w sprawie bezpieczeństwa, regulacji
wzajemnej zgodności, zgodność EMI/EMF, dostępności i Tematy pokrewne,
zobacz Extron bezpieczeństwa i regulacyjnego zgodności przewodnik, część
numer 68-290-01, na stronie internetowej Extron, www.extron.com.
Инструкция по технике безопасности Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан
на продукте, предупреждает пользователя о наличии
неизолированного опасного напряжения внутри корпуса
продукта, которое может привести к поражению электрическим
током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: ,
www.extron.com, номер по каталогу - 68-290-01.
安全说明 简体中文
警告 产品上的这个标志意在警告用户该产品机壳内有暴露的危险 电压,
险。
注意 产品上的这个标志意在提示用户设备随附的用户手册中有
重要的操作和维护(维修说明。
关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍
使用的特性等相关内容,敬请访问 Extron 网站 , www.extron.com,参见
Extron 安全规范指南,产品编号 68-290-01
안전 지침 • 한국어
경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합
니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에
대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및
규제 준수 안내서, 68-290-01 조항을 참조하십시오.
安全記事 • 繁體中文
警告: 若產品上使用此是為了提醒使用者產品機殼內存在著
可能會導致觸電之風險的未絕緣危險電壓。
注意 產品使用此符號,是為提醒使用者設備隨附手冊
重要的操作和維(維修)
有關安全性指導法規遵EMI/EMF 相容性、取範圍和關主題的詳細
訊,請瀏覽 Extron 網站www.extron.com然後參閱《Extron 安全性與法規
守手冊準則編號 68-290-01
安全上の注意
日本語
警告: この 製品上に表示されている場合は、筐体内に絶縁され
いない高電圧が流れ、感電の危険があるを示しています
意:この が製上に表示されている場合は、本機の取明書に
されている重作と保()のについてユーザー
を喚起するものです
安全上の注意、法規厳守、EMI/EMF適合性、その他の関連項目
スト イト www.extron.com よ り Extron Safety
and Regulatory Compliance Guide』 ( P/N 68-290-01) をださい。
Copyright
© 2019 Extron Electronics. All rights reserved.
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks(
®
), registered service marks(
SM
), and trademarks(
TM
) are the property of RGBSystems, Inc. or
ExtronElectronics (see the current list of trademarks on the Terms of Use page at www.extron.com):
Registered Trademarks
(®)
Cable Cubby, ControlScript, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, Flat Field, FlexOS, GlobalViewer, Global Configurator, Global
Scripter, Hideaway, IP Intercom, IP Link, Key Minder, LinkLicense, LockIt, MediaLink, MediaPort, NetPA, PlenumVault, PoleVault, PowerCage,
PURE3, Quantum, SoundField, SpeedMount, SpeedSwitch, System INTEGRATOR, TeamWork, TouchLink, V-Lock, VoiceLift, VN-Matrix, WallVault,
WindoWall, XTP, and XTP Systems
Registered Service Mark
(SM)
: S3 Service Support Solutions
Trademarks
(
)
AAP, AFL (Accu-RATE Frame Lock), ADSP - Advanced Digital Sync Processing, Auto-Image, CableCover, CDRS - Class D Ripple Suppression,
Codec Connect, DDSP (Digital Display Sync Processing), DMI (Dynamic Motion Interpolation), Driver Configurator, DSP Configurator, DSVP (Digital
Sync Validation Processing), eLink, EQIP, EverLast, FastBite, FOX, FOXBOX, HyperLane, IP Intercom HelpDesk, MAAP, MicroDigital, Opti-Torque,
ProDSP, QS-FPC - QuickSwitch Front Panel Controller, Room Agent, Scope-Trigger, ShareLink, Show Me, SIS (Simple Instruction Set), Skew-Free,
SpeedNav, StudioStation, Triple-Action Switching, True4K, Vector™ 4K, VideoLounge, WebShare, XTRA, ZipCaddy, and ZipClip
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause interference. This interference must be corrected at the expense of the user.
ATTENTION: The Twisted Pair Extension technology works with unshielded twisted
pair (UTP) or shielded twisted pair (STP) cables; but to ensure FCC Class A and CE
compliance, STP cables and STP Connectors are required.
For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the “Extron Safety and Regulatory
Compliance Guide” on the Extron website.
NOTES:
This unit was tested with shielded I/O cables on the peripheral devices. Shielded
cables must be used to ensure compliance with FCC emissions limits.
For mor
e information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the “Extron Safety and
Regulatory Compliance Guide” on the Extron website.
Conventions Used in this Guide
Notifications
The following notifications are used in this guide:
CAUTION: Risk of minor personal injury.
ATTENTION : Risque de blessuremineure.
ATTENTION:
Risk of property damage.
Risque de dommages matériels.
NOTE: A note draws attention to important information.
Specifications Availability
Product specifications are available on the Extron website, www.extron.com.
Extron Glossary of Terms
A glossary of terms is available at http://www.extron.com/technology/glossary.aspx.
MTP 1500RL 15HD A Series • Contents
v
Contents
MTP 1500RL 15HD A Series ............................... 1
About this Guide ................................................. 1
About the MTP 1500RL 15HD A Series
Receivers .......................................................... 1
TP Cable Advantages ..................................... 2
Transmission Distance .................................... 2
Application Diagram ........................................... 3
Mounting the Unit ............................................... 3
Connections and Settings................................... 3
Front Panel Controls and Indicators .................... 7
Peaking and Level Adjustment ........................ 8
Skew Delay Compensation ............................. 9
Mounting the Receiver ...................................... 10
Tabletop Use ................................................ 10
Mounting kits ................................................ 10
UL Rack-Mounting Guidelines ...................... 10
MTP 1500RL 15HD A Series • Contents vi
MTP 1500RL 15HD A Series 1
MTP 1500RL 15HD A
Series
About this Guide
About the MTP 1500RL 15HD A Series Receivers
Application Diagram
Installation
Connections and Settings
Fr
ont Panel Controls and Indicators
Mounting the Receiver
About this Guide
This guide details the installation, configuration, and operation of the Extron
MTP 1500RL 15HD A series of Mini Twisted Pair receivers.
MTP 1500RL 15HD A SEQ mini twisted pair receiver with audio and skew equalization
MTP 1500RL 15HD A mini twisted pair receiver with audio
The following terms are applicable in this manual:
“Transmitter” refers specifically to the MTP transmitter.
“Receiver” refers to either MTP 1500RL 15HD A model covered in this guide.
“SEQ receiver” refers specifically to the MTP 1500RL 15HD A SEQ receiver with skew
equalization.
About the MTP 1500RL 15HD A Series Receivers
The Extron MTP 1500RL 15HD A SEQ and MTP 1500RL 15HD A receivers are for long
distance distribution of RGB, component (bi-level or tri-level sync), S-video, or composite
video signals and audio over twisted pair cables.
The MTP 1500RL 15HD A series is a half rack size line of basic twisted pair receivers
that are fully compatible with all MTP transmitters, distribution amplifiers, matrix switchers and
associated video accessories. When used with any of the Extron MTP transmitter models,
the video can be transmitted over an extended distance or over current standard distances.
The MTP 1500RL 15HD A models receive signals up to UXGA, HD component video
(including 1080p), standard component, S-video, bi-level or tri-level component video, and
high resolution RGB video) on an RJ-45 connector over Extron Enhanced Skew-Free A/V
UTP cable, or over Category (CAT) 5 shielded twisted pair (STP), unshielded twisted pair
(UTP), or foil shielded twisted pair (FTP) cable.
The receiver outputs multiple RGB formats, composite video, S-video and component video
on the 15-pin HD connector, according to the current DIP switch settings.
MTP 1500RL 15HD A Series 2
NOTE: The MTP 1500RL 15HD series of receivers cannot be used with VTT or TP
transmitters.
The receivers ship with external desktop 12 V, 1 A power supplies that accept 100 to
240 VAC, 50 Hz to 60 Hz input.
TP Cable Advantages
Twisted pair cable is much smaller, lighter, more flexible, and less expensive than coaxial
cable. These TP products make cable runs simpler and less cumbersome, and termination
with RJ-45 connectors is simple, quick, and economical.
Transmission Distance
The maximum distance is determined by the frequency and resolution of the signal
transmitted. The table below specifies the maximum transmission distances and transmitter
Pre-peak switch positions using Extron Enhanced Skew-Free A/V UTP cable or UTP CAT
cable, terminated with RJ-45 connectors.
Video format Pre-peak off Pre-peak on Maximum distance (feet)
Vid, S-vid, YUV <1300 >1400 1500
640x480 <1300 >1400 1500
800x600 <1300 >1400 1500
1024x768 <1300 >1400 1500
1280x960 <1300 >1400 1500
1280x1024 <1300 >1400 1500
1360x765 <1300 >1400 1500
1365x768 <1300 >1400 1500
1366x768 <1300 >1400 1500
1440x960 <1300 >1400 1500
1440x1050 <1300 >1400 1500
1600x1200 <1300 >1400 1500
1920x1200 <1000 >1100 1200
2048x1080 <1000 >1100 1200
720p <1300 >1400 1500
1080i <1300 >1400 1500
1080p <1300 >1400 1500
NOTE: The transmitter and receiver are designed for and perform best with Extron
Enhanced Skew-Free A/V cable terminated in accordance with the TIA/EIA T568A
standard. CAT 5 cables are acceptable but less preferable. Extron also recommends
the use of preterminated and tested cables. Cables terminated on site should be
tested before use to ensure that they comply with Category 5 specifications.
MTP 1500RL 15HD A Series 3
Application Diagram
MTP
1
50
0R
L 15H
D A
SEQ
P
OWE
R
1
2V
0.
5
A
MA
X
O
U
T
PUT
MONO
L
R
AU
DIO
H +
V +
CSYNC
SOG
VIDEO
END
SPARE
ON
I
NP
UT
B
U
FFE
RED OUTPUT
M
TP
MTP
MTP
15
0
0
RL 15
H
D A SEQ
P
OW
E
R
1
2
V
0.
5
A
M
AX
O
U
TPUT
MONO
L
R
AU
DIO
H +
V +
CSYNC
SOG
VIDEO
END
SPARE
ON
I
NPUT
B
U
FFE
RED OUTPUT
M
TP
MTP
PC
Flat Panel
Display
Flat Pane
l
Display
Extron
MTP 1500RL 15HD A SEQ
Mini Twisted Pair Receiver
with Loop-Through and Skew EQ
1,000 ft UTP Cable
(CAT 5/5e/6)
Audio
Audio
Audio
RGBHV
RGBHV
500 ft UTP Cable
(CAT 5/5e/6)
RGBHV
Extron
MTP 1500RL 15HD A SEQ
Mini Twisted Pair Receiver
with Loop-Through and Skew EQ
Extron
MTP T 15HD A
Mini Twisted Pair
Transmitter
Figure 1. Typical MTP 1500RL 15HD A SEQ Application
Installation
Mounting instructions can be found in Mounting the Receiver on page 10. Compatible
optional hardware is listed on the Extron website (www.extron.com).
Connections and Settings
Figure 2 shows the MTP 1500RL A rear panel. The SEQ receiver is identical.
POWER
12V
1A MAX
MTP 1500RL 15HD A
OUTPUT
MONO
LR
AUDIO
INPUT
BUFFERED OUTPUT
ON
H +
V +
CSYNC
SOG
VIDEO
END
SPARE
MTP
MTP
$$ %% && '' (( ))
Figure 2. Receiver Rear Panel Features
A
Power connector — Plug the included external 12 VDC, 1 A, power supply into this
2-pole captive screw connector. See Power Supply Wiring on page 5 to wire the
connector.
B
Signal input connector — Connect one end of the twisted pair (TP) cable from an
MTP transmitter. See TP Cable Termination on page 6 to wire the connectors.
ATTENTION:
Do not connect this connector to a computer data or telecommunications
network.
Ne connectez pas ces port à des données informatiques ou à un réseau de
télécommunications.
NOTE: Minimum distance from the transmitter is 50 feet.
MTP 1500RL 15HD A Series 4
C
Buffered output connector — Connect up to 8 daisy-chained MTP recievers to this
RJ-45 connector.
NOTE: In a daisy chain, the maximum distance from video source to display device
should not exceed 1500 feet.
D
High resolution video output connector — Connect a projector or other high
resolution video device to this 15-pin HD connector for RGB output.
NOTE: See DIP switch settings for signal format output.
E
Audio connector — Connect a suitable audio device to the 5-pole captive screw
connector for mono audio output.
1
MONO AUDIO
2
1
MONO AUDIO
2
Unbalanced Output
Balanced Output
Do not tin the wires!
Mono output 1-
Sleeve(s)
Mono output 1+
Mono output 2+
Mono output 2-
Sleeve(s)
Mono output 1
Mono output 2
NO GROUND.
NO GROUND.
CAUTION
For unbalanced audio, connect the sleeve(s) to the ground contact.
DO NOT connect the sleeve(s) to the negative (-) contacts.
Figure 3. Audio Connector Wiring
F
Receiver DIP switches — Set these DIP switches for the applicable signal.
H sync (H+) and V sync (V+) switches — Set these switches up (on) for positive
sync or down for negative sync.
Composite sync (CSync), Sync on green (SOG), and Video switches — Set
these switches as shown in the table below to output the indicated format.
Output Format C Sync SOG Video
RGBHV Down Down Up
RGBS Up Down Down
RGsB Down Up Down
Component video* Down Down Up
S-video Down Down Up
Composite video* Down Down
* Input video format must match.
End unit switch — Set this switch up if either of the following is true:
The receiver being configured is the only receiver connected to the transmitter.
The receiver being configured is the last receiver in a daisy-chained system.
MTP 1500RL 15HD A Series 5
Power Supply Wiring
Figure 4 shows how to wire the connector. Insert the wired plug into the power connector
on the rear panel. Do not power on the device at this time.
SECTION A–A
AA
Power Supply
Output Cord
2-Pole Captive Scre
w
Connector
Ridges
Smooth
Tie Wrap
3/16”
(5 mm) Max.
Figure 4. Power Connector Wiring
CAUTION:
ATTENTION :
The wir
es must be kept separate while the power supply is plugged in. Remove
power before wiring.
Les deux cor
dons d’alimentation doivent être maintenus séparés lorsque la
source d’alimentation est branchée. Coupez l’alimentation avant d’effectuer un
raccordement.
The length of exposed wir
es is important. The ideal length is 3/16 inch (5 mm).
Any longer and the exposed wir
es may touch, causing a short circuit between
them.
Any shorter and the wir
es can be easily pulled out even if tightly fastened by the
captive screws.
La longueur des câbles exposés est importante. La longueur idéale est de 5mm
(3/16inches).
S’ils sont tr
op longs, les câbles exposés pourraient se toucher et provoquer un
court-circuit.
S’ils sont tr
op courts, ils peuvent être tirés facilement, même s’ils sont
correctement serrés par les borniers à vis.
Do not tin the power supply leads befor
e installing them in the connector. Tinned
wires are not as secure in the connector and could be pulled out.
Ne pas étamer les conducteurs avant de les insér
er dans le connecteur. Les câbles
étamés ne sont pas aussi bien fixés dans le connecteur et pourraient être retirés.
ATTENTION:
If not provided with a power supply, this product is intended to be supplied by a UL
Listed power source marked “Class 2” or “LPS” and rated output 12V dc, minimum
1.0 A minimum. Always use a power supply supplied by or specified by Extron. Use
of an unauthorized power supply voids all regulatory compliance certification and
may cause damage to the supply and the end product.
Si le produit n’est pas fourni avec une source d’alimentation, il doit être alimenté
par une source d’alimentation certifié UL de classe 2 ou LPS, avec une tension
nominale 12 Vcc, 1 A minimum. Utilisez toujours une source d’alimentation
fournie ou recommandée par Extron. L’utilisation d’une source d’alimentation non
autorisée annule toute conformité réglementaire et peut endommager la source
d’alimentation ainsi que le produit final.
MTP 1500RL 15HD A Series 6
ATTENTION:
Unless otherwise stated, the AC/DC adapters ar
e not suitable for use in air handling
spaces or in wall cavities.
Sauf mention contrair
e, les adaptateurs CA/CC ne conviennent pas à une utilisation
dans les espaces d’aération ou dans les cavités murales.
The installation must always be in accor
dance with the applicable provisions of
National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical
Code part 1, section 16. The power supply shall not be permanently fixed to a
building structure or similar structure.
Cette installation doit toujours conforme aux dispositions applicables du Code
américain de l’électricité (National Electrical Code) ANSI/NFPA 70, article 725, et
du Code canadien de l’électricité, partie1, section16. La source d’alimentation ne
devra pas être fixée de façon permanente à une structure de bâtiment ou à une
structure similaire.
Power supply voltage polarity is critical. Incorr
ect voltage polarity can damage the
power supply and the unit. The ridges on the side of the cord (see figure 4 on the
previous page) identify the power cord negative lead.
La polarité de la source d’alimentation est primordiale. Une polarité incorrecte
pourrait endommager la source d’alimentation et l’unité. Les stries sur le côté du
cordon (voir l’illustration 4 sur la page 5) permettent de repérer le pôle négatif du
cordon d’alimentation.
To verify the polarity before connection, plug in the power supply with no load and check the
output with a voltmeter.
As an alternative, an Extron PS 124 Multiple Output 12 Volt DC Power Supply can power
multiple MTPs or other Extron 12 VDC devices using only one AC power connector.
TP Cable Termination
ATTENTION:
Do not connect this connector to a computer data or telecommunications network.
Ne connectez pas ces port à des données informatiques ou à un r
éseau de
télécommunications.
NOTE: RJ-45 termination must comply with TIA/EIA T568A or TIA/EIA T568B wiring
standards for all connections.
Figure 5 details the TIA/EIA-T568B or TIA/EIA T568B wiring standards. Use this standard
to terminate the DTP cable with RJ-45 connectors.
12345678
RJ-45
Connector
Inser
t Twisted
Pair Wires
Pins:
Pin
1
2
3
4
5
6
7
8
Wire color
White-green
Green
White-orange
Blue
White-blue
Orange
White-brown
Brown
Wire color
T568A T568B
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
Figure 5. TP Cable Termination
MTP 1500RL 15HD A Series 7
NOTES:
If you ar
e using Enhanced Skew-Free A/V cable, use the TIA/EIA T568A standard
only.
Enhanced Skew-fr
ee A/V cable is not recommended for Ethernet/LAN applications.
This cable is specially designed for compatibility with Extr
on Twisted Pair products
that are wired using the TIA/EIA T568A standard.
The table below shows the MTP RJ-45 pin assignments for audio and video signals.
Pin RGBHV RGBS Composite S-Video Component
1 Red/V sync + Red + No Signal Chroma + R-Y +
2 Red/V sync - Red - No Signal Chroma - R-Y -
3 Mono Audio+ Mono Audio + Mono Audio + Mono Audio + Mono Audio +
4 Green + Green + Video + Luma + Y +
5 Green - Green - Video - Luma - Y -
6 Mono Audio - Mono Audio - Mono Audio - Mono Audio - Mono Audio -
7 Blue/H Sync + Blue/C Sync + No Signal No Signal B-Y +
8 Blue/H Sync - Blue/C Sync - No Signal No Signal B- Y -
Front Panel Controls and Indicators
Figure 6 shows the front panel features on the MTP 1500RL 15HD A SEQ. The
MTP 1500RL 15HD A is similar but without the Delay controls (items
D
through
F
on the
next page.
MTP 1500RL SERIES
RGB
PEAKING
LEVEL
DELAY
RED
GREEN
BLUE
SELECT
ADJUST
MIN/MAX
$$ '' (( )) %%&&
Figure 6. MTP receiver series front panels
A
Power LED — Indicates power is applied to the receiver.
B
Level control — Alters the video output voltage to affect the brightness of the
displayed image. Adjust the knob while viewing the displayed image to set the level and
boost that provides the best picture quality. See Peaking and Level Adjustment on
the next page for details.
C
Peaking control — Affects the sharpness of a picture. Increased peaking can
compensate for mid- and high-frequency detail loss from low bandwidth system
components or capacitance in long cables.
Adjust this control while viewing the displayed image to obtain the optimum picture
sharpness. The LED lights red when at the minimum (zero) and maximum (100%)
peaking settings. See Peaking and Level Adjustment for details.
NOTE: To avoid possible video loss due to errors in the format detection, the user
should always start with minimal peaking and level, then only increase values as
required.
MTP 1500RL 15HD A Series 8
D
Select button (SEQ receiver only, see the previous page) — This recessed button
selects the red, green, or blue video signal to adjust and resets all three video signals to
a skew delay of zero nanoseconds.
Use a Tweeker to press and release this button to cycle and select the red, green, or
blue video signal to adjust. The selected signal is indicated by the Red, Green, and Blue
LEDs (
E
).
NOTE: The SEQ receiver automatically saves the setting for the video signal that is
being deselected when this button is pushed or when the selection times out after
10 seconds.
Press and hold the button in for approximately 3 seconds to zero the skew delay for
red, green, and blue. The Red, Green, and Blue LEDS (
E
) all turn off. Release the
button.
E
R(ed), G(reen), and B(lue) LEDs (SEQ receiver only) — These indicate the video signal
that is selected by the Select button (b) for skew adjustment using the Adjust control
(
F
). The LED for the selected color flashes when the skew compensation for that
color’s video signal has reached the minimum or maximum limit.
F
Adjust skew control (SEQ receiver only) — This control delays the selected red,
green, or blue video signal by up to a maximum of 62 nanoseconds (ns), in 2 ns
incremental steps. Rotate the control counterclockwise to reduce the delay or clockwise
to increase the delay. See Skew Delay Compensation on the next page for details.
NOTE: The movement of the Adjust control is smooth; it does not have mechanical
steps or high- and low-limit stops.
Watch the displayed image to observe the steps of delay.
For best performance the skew of the most delayed signal should be set to 0 ns (min.)
and the other two signals adjusted to meet it.
Peaking and Level Adjustment
For best performance and video format detection, the equalization of the MTP receiver
should be adjusted properly.
To achieve this do the following:
1. Terminate the green video signal output with a 75 ohm resistance, and measure the
video signal.
NOTE: Gain adjustment should be set so that a white field video signal is +0.7 volts
from the ground level.
Peaking adjustment should be set using the highest frequency video format signal
for the system in RGB, component video, or S-video.
2. Using an alternative black/white pattern, adjust the peaking so that the video signal
matches that of the white field video. This equalizes both the low frequency (white field)
and the high frequency (alternating black/white field) to the same video level for best
results. Do not over-peak the signal.
MTP 1500RL 15HD A Series 9
Skew Delay Compensation
CAT cable can lead to registration errors between the red, green, and blue video signals.
Pair skew can be measured with test equipment or identified by viewing a crosshatch test
pattern with a critical eye to determine if either the red, green, or blue video image leads
(appears to the left of) the other two video images.
NOTE: Unless the TP cable is changed, the skew adjustment should only need to be
made once, during installation..
SEQ receiver skew compensation
The SEQ receiver has built-in skew compensation capabilities. Adjust the equalization as
follows:
1. Zero the skew delay for red, green, and blue as follows:
a. Use a Tweeker or other small screwdriver to press and hold the Select button for
3 seconds. The Red, Green, and Blue LEDS all go out.
b.
Release the
Select button.
2. Use UTP cable test equipment or examine the displayed video image with a critical eye
to determine which video signal, red, green, or blue, is shifted furthest to the right.
NOTE: A crosshatch test pattern or a black background with vertical white lines is
ideal for determining skew.
3. Adjust the furthest left video signal as follows:
NOTE: The SEQ receiver cannot shift the furthest right video image to the left.
a.
Use a T
weeker or other small screwdriver to press and release the
Select button
until the LED for the left-shifted color (Red, Green, or Blue) lights.
b. Slowly rotate the Adjust control clockwise while monitoring the display. Continue
to rotate the control until that color is properly converged.
NOTE: A 2-nanosecond (ns) adjustment is very fine. Up to 10 ns of delay may
be necessary before a change in the display is detectable. Maximum delay
possible is 62 nanoseconds.
c.
Use a T
weeker or other small screwdriver to press the
Select button one more
time to save the most recent adjustment or allow the 10-second timeout to elapse.
4. If the remaining color is left shifted, repeat step 3.
Non-SEQ receivers skew compensation
Try using the following methods to minimize or eliminate pair skew:
Switch to Extron Enhanced Skew-Free A/V UTP cable.
Add a skew compensation cable equal to the length of pair skew to the receiver’s
output.
Install an Extron SEQ 100 15HD Skew Equalizer on the video output of the receiver and
adjust the skew for the leading video image.
MTP 1500RL 15HD A Series 10
Mounting the Receiver
ATTENTION:
Installation and service must be performed by authorized personnel only
.
L
’installation et l’entretien doivent être effectués par le personnel autorisé
uniquement.
The 1-inch high, half rack width receiver can be placed on a table, mounted in a rack, or
mounted under a desk or table.
Tabletop Use
Affix the included rubber feet to the bottom of the unit and place it in any convenient
location.
Mounting kits
Mount the unit using any optional compatible mounting kit listed on the Extron website
(www.extron.com), in accordance with the directions included with the kit. For rack
mounting, see “UL Rack-Mounting Guidelines”.
UL Rack-Mounting Guidelines
The following Underwriters Laboratories (UL) requirements pertain to the installation of the
unit into a rack.
Elevated operating ambient temperature — If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater
than room ambient. Therefore, consider installing the equipment in an environment
compatible with the maximum ambient temperature (TMA = +122 °F, +50 °C) specified
by Extron.
Reduced air flow — Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not compromised.
Mechanical loading — Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
Circuit overloading — Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits might have
on overcurrent protection and supply wiring. Appropriate consideration of equipment
nameplate ratings should be used when addressing this concern.
Reliable earthing (gr
ounding) — Reliable earthing of rack-mounted equipment
should be maintained. Particular attention should be given to supply connections other
than direct connections to the branch circuit (such as use of power strips).
Extron Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years
from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty
workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components,
to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is
returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South America,
and Central America:
Extron Electronics
1230 South Lewis Street
Anaheim, CA 92805
U.S.A.
Japan:
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho
Chiyoda-ku, Tokyo 102-0082
Japan
Europe and Africa:
Extron Europe
Hanzeboulevard 10
3825 PH Amersfoort
The Netherlands
China:
Extron China
686 Ronghua Road
Songjiang District
Shanghai 201611
China
Asia:
Extron Asia Pte Ltd
135 Joo Seng Road, #04-01
PM Industrial Bldg.
Singapore 368363
Singapore
Middle East:
Extron Middle East
Dubai Airport Free Zone
F13, PO Box 293666
United Arab Emirates, Dubai
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical
or mechanical abuse, abnormal operating conditions, or if modifications were made to the product that were not
authorized by Extron.
NOTE: If a product is defective, please call Extron and ask for an Application Engineer to receive an RA (Return
Authorization) number. This will begin the repair process.
USA: 714.491.1500 or 800.633.9876 Europe: 31.33.453.4040
Asia: 65.6383.4400 Japan: 81.3.3511.7655
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage
during shipment. Returned units must include the serial number and a description of the problem, as well as the
name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality,
performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct,
indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been
advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may
not apply to you.
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe
+800.3987.6673
(Inside Europe Only)
+31.33.453.4040
+31.33.453.4050 FAX
Extron Asia
+65.6383.4400
+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron China
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Middle East
+971.4.299.1800
+971.4.299.1880 FAX
Extron Australia
+61.8.8113.6800
+61.8.8351.2511 FAX
Extron India
1800.3070.3777
(Inside India Only)
+91.80.3055.3777
+91.80.3055.3737 FAX
© 2019 Extron Electronics All rights reserved. www.extron.com
Contact Information
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17

Extron MTP 1500RL 15HD A SEQ Manuel utilisateur

Catégorie
Glacières
Taper
Manuel utilisateur

dans d''autres langues