Power Fist 8887135 Le manuel du propriétaire

Taper
Le manuel du propriétaire

Ce manuel convient également à

V1.0 8887135
Please read and understand all instructions before use. Retain this manual for
future reference.
8887135 1/2 HP Cast-Iron Sewage Pump V1.0
2 For technical questions call 1-800-665-8685
SPECIFICATIONS
Horsepower 1/2 HP
Voltage 115 VAC
Amperage 7.8 A
Duty Cycle Continuous
Discharge Size 2 in.
Max. Discharge Height 27 ft
Flow Rate @ 5 ft. 4,800 GPH
Flow Rate @ 10 ft. 4,050 GPH
Flow Rate @ 15ft. 3,200 GPH
Flow Rate @ 20 ft. 2,200 GPH
Handles Solids 3/4 in.
Construction Cast iron
Dimensions 10 x 6.2 x 14.5 in.
HAZARD DEFINITIONS
Please familiarize yourself with the hazard notices found in this manual. A
notice is an alert that there is a possibility of property damage, injury or
death if certain instructions are not followed.
DANGER! This notice indicates an immediate and specific hazard that will
result in severe personal injury or death if the proper
precautions are not taken.
WARNING! This notice indicates a specific hazard or unsafe practice that
could result in severe personal injury or death if the proper
precautions are not taken.
CAUTION! This notice indicates a potentially hazardous situation that may
result in minor or moderate injury if proper practices are not
taken.
NOTICE! This notice indicates that a specific hazard or unsafe practice
will result in equipment or property damage, but not personal
injury.
V1.0 1/2 HP Cast-Iron Sewage Pump 8887135
Visit www.princessauto.com for more information 3
SAFETY
WARNING! Read and understand all instructions before using this tool. The
operator must follow basic precautions to reduce the risk of personal injury
and/or damage to the equipment.
Keep this manual for safety warnings, precautions, operating or inspection
and maintenance instructions.
WORK AREA
1. Operate in a safe work environment. Keep your work area clean, well-
lit and free of distractions. Place lights so you are not working in a
shadow.
2. Keep anyone not wearing the appropriate safety equipment away from
the work area.
3. Store unused tools properly in a safe and dry location to prevent rust
or damage. Lock tools away and keep out of the reach of children.
4. Do not install or use in the presence of flammable gases, dust or
liquids.
PERSONAL SAFETY
WARNING! Wear personal protective equipment approved by the Canadian
Standards Association (CSA) or American National Standards Institute (ANSI).
PERSONAL PROTECTIVE EQUIPMENT
1. Always wear impact safety goggles that provide front and side
protection for the eyes. Eye protection equipment should comply with
CSA Z94.3-07 or ANSI Z87.1 standards based on the type of work
performed.
2. Wear gloves that provide protection based on the work materials or to
reduce the effects of tool vibration.
3. Wear protective clothing designed for the work environment and tool.
4. Non-skid footwear is recommended to maintain footing and balance in
the work environment.
5. Wear a NIOSH approved respirator when working on materials that
produce hazardous fumes, dust or particulate matter.
PERSONAL PRECAUTIONS
Control the tool, personal movement and the work environment to avoid
personal injury or damage to tool.
8887135 1/2 HP Cast-Iron Sewage Pump V1.0
4 For technical questions call 1-800-665-8685
1. Do not operate any tool when tired or under the influence of drugs,
alcohol or medications.
2. Avoid wearing clothes or jewelry that can become entangled with the
moving parts of a tool. Keep long hair covered or bound.
3. Do not overreach when operating a tool. Proper footing and balance
enables better control in unexpected situations.
SPECIFIC SAFETY PRECAUTIONS
WARNING! DO NOT let comfort or familiarity with product (gained from
repeated use) replace strict adherence to the tool safety rules. If you use
this tool unsafely or incorrectly, you can suffer serious personal injury.
1. Use the correct tool for the job. This tool was designed for a specific
function. Do not modify or alter this tool or use it for an unintended
purpose.
2. Do not use the tool if any parts are damaged, broken, or misplaced.
Repair or replace the parts.
3. Do not run the pump if there is no water in the system.
4. Do not use pumps in water over 40°C (104°F). Avoid draining hot water
tanks into sump pits.
5. Do not power this device with anything other than a 120 volt power
source.
6. Do not use pumps for pumping mud, sand, cement, fats, salt, waste
water from toilets, oils, combustible or explosive substances or
chemicals.
7. The appliance is intended for pumping rainwater, fresh water, mains
water and chlorinated swimming pool water.
8. The pump must not be used for drinking water supply or for the
delivery of foodstuffs.
9. The device is not suitable for commercial or industrial use.
10. The pump is not suitable for continuous running (such as permanent
circulation in filter systems).
11. Risk of fire or explosion. Do not pump flammable or explosive fluids
such as gasoline, fuel oil, kerosene, etc.
12. Do not lift the pump by the power cord.
13. Be certain the pump power source is disconnected before installing or
servicing the pump.
V1.0 1/2 HP Cast-Iron Sewage Pump 8887135
Visit www.princessauto.com for more information 5
14. Do not expose the pump to freezing temperatures. Freezing could
cause severe damage and will void the warranty.
15. Do not insert fingers or any object into the pump or motor openings.
16. The pump normally runs hot. To avoid burns when servicing the pump,
allow it to cool for twenty minutes after shutdown before handling it.
17. Always check the pump before each operation. A damaged pump must
not be used. Have the pump serviced by a qualified service technician.
ELECTRICAL SAFETY
WARNING! Hazardous voltage can shock, burn or kill. When installing,
operating or servicing this pump, follow the safety instructions listed below.
1. Before installing this product, have the electrical circuit checked by an
electrician to ensure proper grounding.
2. Connect this product to a grounded circuit equipped with a Ground
Fault Circuit Interrupter (GFCI) device.
3. Do not install the pump in any location classified as hazardous by the
National Electrical Code, ANSI / NFPA 80-1984 or the Canadian Electrical
Code.
4. Do not allow the plug on the end of the electrical cord to be
submerged.
5. Do not use extension cords. They are a fire hazard and can reduce the
voltage sufficiently to prevent pumping and / or damage the motor.
6. Do not handle or service the pump while it is connected to the power
supply.
7. Ground the motor before connecting to an electrical supply.
8. Failure to ground the motor can cause severe or fatal electrical shock.
9. Do not ground to a gas supply line.
10. To avoid dangerous or fatal electrical shock, turn off the power to the
motor before working on electrical connections.
11. Check the voltage on the motor nameplate and make sure that the line
voltage of the electrical current supply is the same.
12. The supply voltage must be within 10% of the nameplate voltage.
Incorrect voltage can cause fire or seriously damage the motor and
voids the warranty. If in doubt, contact a licensed electrician.
13. Meet all national electrical code and local codes for all wiring.
8887135 1/2 HP Cast-Iron Sewage Pump V1.0
6 For technical questions call 1-800-665-8685
14. Do not handle a pump or pump motor with wet hands, or when
standing on a wet or damp surface or in water.
15. Always disconnect the power source before performing any work on or
near the motor or its connected load.
16. Protect yourself against electric shocks when working on electrical
equipment. Avoid body contact with grounded surfaces. There is an
increased chance of electrical shock if your body is grounded.
17. The fuse must be a residual current circuit-breaker with a measured
residual current of no more than 30 mA.
18. If the device is not in use, make sure that the plug is removed from the
power source.
19. Make sure that the device is switched off before plugging in the mains
cable.
20. Make sure that the device is switched off before unplugging it.
21. Disconnect the power supply before moving or transporting the device.
22. Do not install and switch on the pump if there are people or animals in
the medium, or have contact with the medium being pumped (such as
swimming pools).
WARNING! A qualified electrician should perform all wiring.
POWER CORD
1. Do not operate this tool if the power cord is frayed or damaged as an
electric shock may occur, resulting in personal injury or property damage.
a. Inspect the tool's power cord for cracks, fraying or other faults in
the insulation or plug before each use.
b. Discontinue use if a power cord feels more than comfortably
warm while operating the tool.
c. Have the power cord replaced by a qualified service technician.
2. Keep all connections dry and off the ground to reduce the risk of
electric shock. Do not touch plug with wet hands.
3. Prevent damage to the power cord by observing the following:
a. Never use the cord to carry the tool.
b. Do not pull on the cord to disconnect the plug from an outlet.
c. Keep the power cord clear of the tool and the tool's work path
while in operation. The cord should always stay behind the tool.
V1.0 1/2 HP Cast-Iron Sewage Pump 8887135
Visit www.princessauto.com for more information 7
d. Keep cord away from heat, oil, sharp edges or moving parts.
4. Do not allow people, mobile equipment or vehicles to pass over
unprotected power cords.
a. Position power cords away from traffic areas.
b. Place cords in reinforced conduits.
c. Place planks on either side of the power cord to create a
protective trench.
UNPACKING
WARNING! Do not operate the tool if any part is missing. Replace the
missing part before operating. Failure to do so could result in a malfunction
and personal injury.
Remove the parts and accessories from the packaging and inspect for damage.
IDENTIFICATION KEY
A Carrying Ring
B Float Switch
C Pump Casing
D Discharge Outlet
INSTALLATION
When this manual refers to a part number, it refers
to the included Parts Identification section.
INSTALLATION
CAUTION! This pump is intended to pump water only, with a maximum
temperature of 40°C (105°F). Do not pump heated liquids.
CAUTION! The motor housing transfers heat to the volute. This pump is
capable of operating with the motor housing partially exposed for extended
periods, while still providing sufficient motor cooling and bearing lubrication.
However, for the best cooling and longest motor life, the level of the liquid
being pumped should normally be above the top of the motor housing.
1. Place the pump on a hard, level surface in a suitable, gas-tight basin
that is at least 11 in. (28 cm) diameter and 18 in. (46 cm) deep. Never
place the pump directly on clay, earth, or gravel surfaces.
8887135 1/2 HP Cast-Iron Sewage Pump V1.0
8 For technical questions call 1-800-665-8685
2. Install the pump with ABS, PVC, polyethylene or galvanized steel pipe.
Use the proper adapters to connect plastic pipe to the pumps
discharge outlet (D).
3. Install a check valve in the discharge line to prevent the backflow of
liquid into the basin. The check valve should be a free-flow valve that
will easily pass solids.
a. For the best performance when handling solids, install the check
valve horizontally or at an angle of no more than 45°. Do not
install the check valve vertically because solids may settle in the
valve and prevent it from opening on start-up.
4. When using a check valve, drill a 1/8 in. (3.175 mm) or 3/16 in. (4.8 mm)
diameter relief hole in the discharge pipe below the floor line between
the pump discharge and the check valve. Otherwise, the pump could
air lock and will not pump water even though the pump will run.
TESTING
When the pump is installed in a basin with a sealed cover, you cannot
observe the operation of the float switch. The cover usually will have a
spare hole that is blocked with a rubber plug. Remove this plug to observe
the switch operation during testing.
1. Check the pump label for proper voltage required.
2. Plug the power cord directly into a GFCI equipped electrical outlet.
3. Run water into the basin until the pump starts.
4. Be sure the check valve in the discharge line is open.
5. Allow the pump to operate through several on / off cycles.
CARE & MAINTENANCE
WARNING! Disconnect the pump from the power source before servicing.
WARNING! If the power is on to the pump when the thermal overload resets,
the pump may start without warning. If you are working on the pump, you
may get an electrical shock or the impeller may catch fingers or tools.
This pump has no serviceable parts. The motor housing of the pump is
completely sealed and requires no service. Disassembly of the motor
housing or alteration of the power cord will void all warranties. The power
cord on this pump cannot be replaced. If it becomes damaged, the entire
pump must be replaced.
V1.0 1/2 HP Cast-Iron Sewage Pump 8887135
Visit www.princessauto.com for more information 9
1. Cycle the pump at least once every month to be sure that the system is
working properly.
2. Before removing the pump from the basin for service, always
disconnect the electrical power source to the pump and the control
switch. Do not lift the pump by the power cord.
DISINFECT THE PUMP
Place the pump in an area where it can be cleaned thoroughly. Remove all
scale and deposits on the pump.
IMPORTANT! Wear rubber or plastic gloves when handling the pump for
service. Completely submerge the pump in a disinfectant solution for at
least one hour .
LUBRICATION
The pump is permanently lubricated. No oiling or greasing is required in
normal operation.
STORAGE
The pump should not be stored outside; the pump could get damaged from
rain and ice. Keep the pump in a cool, dry place. Do not store the pump in
direct sunlight.
REMOVAL FROM STORAGE
Before using the pump again, first soak the pump so that any possible dirt
residues do not block the appliance.
DISPOSAL
Recycle a tool damaged beyond repair at the appropriate facility.
TROUBLESHOOTING
Visit a Princess Auto Ltd. location for a solution if the tool does not function
properly or parts are missing. If unable to do so, have a qualified technician
service the tool.
8887135 1/2 HP Cast-Iron Sewage Pump V1.0
10 For technical questions call 1-800-665-8685
Problem(s) Possible Cause(s) Suggested Solution(s)
Pump does not
turn on.
1. The pump is not
plugged in.
2. Circuit breaker shutoff
or the fuse is removed.
3.
Accumulation of buildup
on the float.
4. The float is obstructed.
5. Defective motor.
1. Plug in the pump.
2. Turn on the circuit breaker or
replace the fuse.
3. Clean the float.
4.
Check the float path and provide
clearance.
5. Have the pump serviced by an
authorized service centre.
The pump will
not shut off.
1. The float is obstructed.
2. The pump is air locked.
3. The liquid inflow has
reached the pumps
capacity.
1.
Check the float path and provide
clearance.
2. Shut the power off for
approximately 1 minute then
restart the pump. Repeat several
times to clear the air from the
pump.
3. A larger pump is required.
The pump runs
but does not
discharge
liquid.
1. The check valve is
installed backwards.
2. The check valve is stuck
or plugged.
3. The lift is too high for
the pump.
4. The inlet to the impeller
is plugged.
5. The pump is air locked.
1. Check the flow indicating arrow
on the check valve body to
insure it is installed properly.
2. Remove the check valve and
inspect for proper operation.
3. Check the rating table in the
Specifications section.
4. Remove the pump from service
and clean.
5. Shut the power off for
approximately 1 minute, then
restart the pump. Repeat several
times to clear the air from the
pump.
The pump does
not deliver the
rated capacity.
1. The lift is too high for
the pump.
2. Low voltage, the speed
is too slow.
3. The impeller or
discharge pipe is closed.
1. Check the rated pump
performance.
2. Check for proper voltage to
make certain it corresponds to
the nameplate voltage.
3. Remove the pump from service
and clean.
V1.0 1/2 HP Cast-Iron Sewage Pump 8887135
Visit www.princessauto.com for more information 11
Problem(s) Possible Cause(s) Suggested Solution(s)
The pump
cycles
continually.
1. No check valve in a long
discharge pipe is
allowing liquid to drain
back into the sump.
2. The check valve is
leaking.
3. The basin is too small
for the inflow.
1. Install a check valve in the
discharge line.
2. Inspect the check valve for the
correct operation.
3. Install a larger basin.
8887135 1/2 HP Cast-Iron Sewage Pump V1.0
12 For technical questions call 1-800-665-8685
PARTS BREAKDOWN
PARTS LIST
# DESCRIPTION QTY
1 Head cover 1
2 Float switch 1
3 Motor housing 1
4 Impeller 1
5 Pump body 1
V1.0 1/2 HP Cast-Iron Sewage Pump 8887135
Visit www.princessauto.com for more information 13
8887135 1/2 HP Cast-Iron Sewage Pump V1.0
14 For technical questions call 1-800-665-8685
V1,0 8887135
Vous devez lire et comprendre toutes les instructions avant d'utiliser l'appareil.
Conservez ce manuel afin de pouvoir le consulter plus tard.
8887135 Pompe pour Eaux Usées En Fonte de 1/2 CV V1,0
2 En cas de questions techniques, appelez le 1-800-665-8685
SPÉCIFICATIONS
Puissance nominale 1/2 C
Tension nominale 115 V c.a.
Courant nominal 7,8 A
Cycle de service Continu
Taille de refoulement 2 po
Haut. max. de refoulement 27 pi
Débit à 5 pi 4 800 gal/h
Débit à 10 pi 4 050 gal/h
Débit à 15 pi 3 200 gal/h
Débit à 20 pi 2 200 gal/h
Acc. les particules solides 3/4 po
Construction Fonte
Dim. (long x larg. x haut.) 10 à 6,2 à 14,5 po
DÉFINITIONS DE DANGER
Veuillez-vous familiariser avec les avis de danger qui sont présentés dans ce
manuel. Un avis est une alerte indiquant qu'il existe un risque de dommage
à la propriété, de blessure ou de décès si on ne respecte pas certaines
instructions.
DANGER! Cet avis indique un risque immédiat et particulier qui
entraînera des blessures corporelles graves ou même la
mort si on omet de prendre les précautions nécessaires.
AVERTISSEMENT! Cet avis indique un risque particulier ou une pratique non
sécuritaire qui pourrait entraîner des blessures
corporelles graves ou même la mort si on omet de
prendre les précautions nécessaires.
ATTENTION! Cet avis indique une situation possiblement dangereuse qui
peut entraîner des blessures mineures ou modérées si on
ne procède pas de la façon recommandée.
AVIS! Cet avis indique un risque particulier ou une pratique non
sécuritaire qui entraînera des dommages au niveau de
l'équipement ou des biens, mais non des blessures
corporelles.
V1,0 Pompe pour Eaux Usées En Fonte de 1/2 CV 8887135
Visitez www.princessauto.com pour plus d'informations 3
SÉCURITÉ
AVERTISSEMENT! Veuillez lire et comprendre toutes les instructions avant
d'utiliser cet outil. L'utilisateur doit respecter les précautions de base
lorsqu'il utilise cet outil afin de réduire le risque de blessure ou de
dommage à l'équipement.
Conservez ce manuel qui contient les avertissements de sécurité, les
précautions, les instructions de fonctionnement ou d'inspection et d'entretien.
AIRE DE TRAVAIL
1. Travaillez dans un environnement de travail sécuritaire. Gardez votre
aire de travail propre, bien éclairée et exempte de toute distraction.
Placez les lampes de façon à ne pas travailler dans lombre.
2. Assurez-vous que les personnes qui ne portent pas l'équipement de
sécurité approprié ne se trouvent pas à proximité de l'aire de travail.
3. Rangez les outils correctement dans un lieu sécurisé et sec. Gardez les
outils hors de la portée des enfants.
4. N'installez pas et n'utilisez pas d'outils électriques en présence de gaz,
de poussière ou de liquides inflammables.
SÉCURI PERSONNELLE
AVERTISSEMENT! Portez de l'équipement de protection personnelle
homologué par l'Association canadienne de normalisation (CSA) ou
l'American National Standards Institute (ANSI).
ÉQUIPEMENT DE PROTECTION PERSONNELLE
1. Portez toujours des lunettes antiprojections qui offrent une protection
frontale et latérale pour les yeux. L'équipement de protection des yeux
devrait être conforme à la norme CSA Z94.3-07 ou ANSI Z87.1 fonction
du type de travail effectué.
2. Portez des gants qui protègent en fonction des matériaux de travail et
pour réduire les effets des vibrations de l'outil.
3. Portez des vêtements de protection conçus pour l'environnement de
travail et pour l'outil.
4. Les chaussures antidérapantes sont recommandées pour maintenir la
stabilité et l'équilibre au sein de l'environnement de travail.
5. Portez un appareil respiratoire approuvé par la NIOSH pour travailler
sur des matériaux qui produisent des émanations dangereuses, de la
poussière ou des particules.
8887135 Pompe pour Eaux Usées En Fonte de 1/2 CV V1,0
4 En cas de questions techniques, appelez le 1-800-665-8685
PRÉCAUTIONS PERSONNELLES
Gardez le contrôle de l'outil, de vos mouvements et de l'environnement de
travail pour éviter les blessures ou le bris de l'outil.
1. N'utilisez pas l'outil si vous êtes fatigué ou sous l'effet de drogues,
d'alcool ou de médicaments.
2. Évitez de porter des vêtements ou des bijoux pouvant se prendre dans
les pièces mobiles d'un outil. Gardez les cheveux longs recouverts ou
attachés.
3. N'utilisez pas l'outil si vous devez étirer les bras pour vous en servir.
Une stabilité et un équilibre appropriés sont nécessaires afin d'avoir un
meilleur contrôle en cas de situations inattendues.
CONSIGNES DE SÉCURITÉ SPÉCIFIQUES
DANGER! Ne permettez PAS au confort ou à votre familiarisation avec l'outil
(obtenus après un emploi répété) de se substituer à une adhésion stricte aux
règles de sécurité de l'outil. Si vous utilisez cet outil de façon dangereuse ou
incorrecte, vous pouvez subir des blessures corporelles graves.
1. Utilisez le bon outil pour la tâche à effectuer. Cet outil a été conçu pour
une utilisation spécifique. Évitez de modifier ou d'altérer cet outil ou de
l'utiliser à une fin autre que celle pour laquelle il a été conçu.
2. N'utilisez pas l'outil si des pièces sont endommagées, cassées ou
égarées. Réparer ou remplacer les pièces.
3. Ne faites pas fonctionner la pompe s'il n'y a pas d'eau dans le système.
4. N'utilisez pas les pompes dans une eau dont la température est
supérieure à 40 °C (104 °F). Évitez de vider les réservoirs d'eau chaude
dans les puisards.
5. N'alimentez pas cet appareil avec toute source d'énergie autre qu'une
alimentation de 120 V.
6. N'utilisez pas les pompes afin de pomper de la boue, du sable, du
ciment, des graisses, du sel, les eaux usées des toilettes, des huiles,
des substances combustibles ou explosives ou des produits chimiques.
7. L'appareil a pour but de pomper l'eau de pluie, l'eau douce, l'eau de
conduite principale ainsi que l'eau de piscine chlorée.
8. La pompe ne doit pas être utilisée pour pomper de l'eau potable ou
pour acheminer des produits alimentaires.
9. L'appareil ne convient pas à un usage industriel ou commercial.
V1,0 Pompe pour Eaux Usées En Fonte de 1/2 CV 8887135
Visitez www.princessauto.com pour plus d'informations 5
10. La pompe ne peut pas fonctionner de manière continue (par exemple, pour
entretenir une circulation permanente dans les systèmes de filtration).
11. Risque d'incendie ou d'explosion. Ne pompez pas des liquides
inflammables ou explosifs comme l'essence, le carburant, l'huile, le
kérosène, etc.
12. Ne soulevez pas la pompe au moyen du cordon d'alimentation.
13. Assurez-vous que la source d'énergie de la pompe est déconnectée
avant d'installer ou d'entretenir la pompe.
14. N'exposez pas la pompe aux températures de congélation. Le gel
pourrait causer des dommages graves, ce qui annulera la garantie.
15. N'introduisez pas de doigt ou d'objet dans les orifices de la pompe ou
du moteur.
16. La pompe est normalement chaude lorsqu'elle est en marche. Pour
éviter les brûlures lors de l'entretien de la pompe, laissez-la refroidir
pendant 20 minutes après l'arrêt avant sa manutention.
17. Vérifiez toujours la pompe avant chaque utilisation. Évitez d'utiliser la
pompe si elle est endommagée. Confiez l'entretien de la pompe à un
technicien de service qualifié.
SÉCURITÉ EN ÉLECTRICI
AVERTISSEMENT! Les tensions dangereuses peuvent électrocuter, brûler ou
causer la mort. Lors de l'installation, de l'utilisation ou de l'entretien de
cette pompe, observez les instructions de sécurité énoncées ci-dessous.
1. Avant d'installer ce produit, faites vérifier le circuit électrique par un
électricien afin d'assurer une mise à la masse efficace.
2. Évitez que la fiche à l'extrémité du cordon d'alimentation ne soit
submergée.
3. Reliez ce produit à un circuit à la masse muni d'un dispositif de
disjoncteur de fuite à la terre (GFCI).
4. N'installez pas la pompe dans un endroit qualifié de dangereux dans le
Code électrique national, dans la norme ANSI/NFPA 80-1984 ou dans le
Code canadien de l'électricité.
5. N'utilisez pas de rallonges de câble. Ils constituent un risque d'incendie
et peuvent réduire la tension suffisamment pour empêcher le pompage
ou endommager le moteur.
6. Ne tentez pas de manipuler ou d'entretenir la pompe alors qu'elle est
reliée à une source d'énergie.
8887135 Pompe pour Eaux Usées En Fonte de 1/2 CV V1,0
6 En cas de questions techniques, appelez le 1-800-665-8685
7. Placez le moteur à la masse avant de le brancher à une source d'énergie.
8. À défaut de mettre le moteur à la masse, il peut en résulter un choc
électrique grave ou même fatal.
9. Ne mettez pas le moteur à la masse en le connectant à une conduite
d'alimentation de gaz.
10. Pour éviter un choc électrique dangereux ou fatal, coupez l'alimentation au
niveau du moteur avant de travailler sur les connexions électriques.
11. Vérifiez la tension sur la plaque signalétique du moteur et assurez-vous
que la tension de ligne de l'alimentation en courant est identique.
12. La tension d'alimentation électrique doit se situer à 10 % près de la
tension indiquée sur la plaque signalétique. Une tension incorrecte
peut causer un incendie ou des dommages graves au moteur, annulant
ainsi la garantie. En cas de doute, contactez un électricien qualifié.
13. Respectez les exigences de tout le Code national électrique et des
codes locaux pour tout le câblage.
14. Évitez de manier la pompe ou le moteur de pompe avec les mains humides
ou si vous vous trouvez sur une surface humide ou moite ou dans l'eau.
15. Coupez toujours la source d'énergie avant d'effectuer tout travail sur
ou près du moteur ou de sa charge branchée.
16. Progez-vous contre les chocs électriques lorsque vous travaillez en
présence d'équipement électrique. Évitez que le corps entre en contact
avec des surfaces mises à la terre. Il y a un risque plus élevé de choc
électrique si votre corps est mis à la terre.
17. Le fusible doit être un disjoncteur présentant un courant résiduel
mesuré ne dépassant pas 30 mA.
18 Si l'appareil n'est pas utilisé, assurez-vous que la fiche a été retirée de
la source d'énergie.
19. Assurez-vous de placer l'appareil hors tension avant de brancher le
câble de secteur.
20. Assurez-vous de placer l'appareil hors tension avant de le débrancher.
21. Débranchez la source d'alimentation avant de déplacer ou de
transporter l'appareil.
22. N'installez et n'actionnez pas la pompe si des personnes ou des
animaux se trouvent dans la source de liquide ou sont en contact avec
la source de liquide pompée (comme une piscine).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Power Fist 8887135 Le manuel du propriétaire

Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues