Power Fist 8887184 Le manuel du propriétaire

Taper
Le manuel du propriétaire
V1.0 8887184
Please read and understand all instructions before use. Retain this manual for
future reference.
8887184 1/3 HP Sump Pump V1.0
2 For technical questions call 1-800-665-8685
SPECIFICATIONS
Horsepower 1/3 HP
Voltage / Amperage 115 VAC / 4.6 A
Duty Cycle Continuous
Discharge Size 1 1/2 in.NPT with 1 1/4 in. adapter
Max. Discharge Head 27 ft
Flow Rate @ 5 ft 2,840 GPH
Flow Rate @ 10 ft 2,480 GPH
Flow Rate @ 15 ft 2,050 GPH
Flow Rate @ 20 ft 1,460 GPH
Material Housing Thermoplastic
Impeller Nylon
Volute Thermoplastic
Dimensions (L x W x H) 7.9 x 7.9 x 10.8 in.
Switch Type Tethered Switch
Cord Length 10 ft
Ambient Temperature 104°F (40°C)
Fluid Temperature 77°F (25°C)
HAZARD DEFINITIONS
Please familiarize yourself with the hazard notices found in this manual. A
notice is an alert that there is a possibility of property damage, injury or
death if certain instructions are not followed.
DANGER! This notice indicates an immediate and specific hazard that
will result in severe personal injury or death if the proper
precautions are not taken.
WARNING! This notice indicates a specific hazard or unsafe practice that
could result in severe personal injury or death if the proper
precautions are not taken.
CAUTION! This notice indicates a potentially hazardous situation that
may result in minor or moderate injury if proper practices are
not taken.
NOTICE! This notice indicates that a specific hazard or unsafe practice
will result in equipment or property damage, but not personal
injury.
V1.0 1/3 HP Sump Pump 8887184
Visit www.princessauto.com for more information 3
SAFETY
WARNING! Read and understand all instructions before using this tool. The
operator must follow basic precautions to reduce the risk of personal injury
and/or damage to the equipment.
Keep this manual for safety warnings, precautions, operating or inspection
and maintenance instructions.
WORK AREA
1. Operate in a safe work environment. Keep your work area clean, well-
lit and free of distractions. Place lights so you are not working in a
shadow.
2. Keep anyone not wearing the appropriate safety equipment away from
the work area.
3. Store unused tools properly in a safe and dry location to prevent rust
or damage. Lock tools away and keep out of the reach of children.
4. Do not install or use in the presence of flammable gases, dust or
liquids.
PERSONAL SAFETY
WARNING! Wear personal protective equipment approved by the Canadian
Standards Association (CSA) or American National Standards Institute (ANSI).
PERSONAL PROTECTIVE EQUIPMENT
1. Always wear impact safety goggles that provide front and side
protection for the eyes. Eye protection equipment should comply with
CSA Z94.3-07 or ANSI Z87.1 standards based on the type of work
performed.
2. Wear gloves that provide protection based on the work materials or to
reduce the effects of tool vibration.
3. Wear protective clothing designed for the work environment and tool.
4. Non-skid footwear is recommended to maintain footing and balance in
the work environment.
5. Wear a NIOSH approved respirator when working on materials that
produce hazardous fumes, dust or particulate matter.
PERSONAL PRECAUTIONS
Control the tool, personal movement and the work environment to avoid
personal injury or damage to tool.
8887184 1/3 HP Sump Pump V1.0
4 For technical questions call 1-800-665-8685
1. Do not operate any tool when tired or under the influence of drugs,
alcohol or medications.
2. Avoid wearing clothes or jewelry that can become entangled with the
moving parts of a tool. Keep long hair covered or bound.
3. Do not overreach when operating a tool. Proper footing and balance
enables better control in unexpected situations.
SPECIFIC SAFETY PRECAUTIONS
WARNING! DO NOT let comfort or familiarity with product (gained from
repeated use) replace strict adherence to the tool safety rules. If you use
this tool unsafely or incorrectly, you can suffer serious personal injury.
1. Use the correct tool for the job. This tool was designed for a specific
function. Do not modify or alter this tool or use it for an unintended
purpose.
2. Do not use the tool if any parts are damaged, broken, or misplaced.
Repair or replace the parts.
3. Do not run the pump if there is no water in the system.
4. Do not use pumps in water over 40°C (104°F). Avoid draining hot water
tanks into sump pits.
5. Do not power this device with anything other than a 120 volt power
source.
6. Do not use pumps for pumping mud, sand, cement, fats, salt, waste
water from toilets, oils, combustible or explosive substances or
chemicals.
7. The appliance is intended for pumping rainwater, fresh water, mains
water and chlorinated swimming pool water.
8. The pump must not be used for drinking water supply or for the
delivery of foodstuffs.
9. The device is not suitable for commercial or industrial use.
10. Risk of fire or explosion. Do not pump flammable or explosive fluids
such as gasoline, fuel oil, kerosene, etc.
11. Do not lift the pump by the power cord.
12. Be certain the pump power source is disconnected before installing or
servicing the pump.
13. Do not expose the pump to freezing temperatures. Freezing could
cause severe damage and will void the warranty.
V1.0 1/3 HP Sump Pump 8887184
Visit www.princessauto.com for more information 5
14. Do not insert fingers or any object into the pump or motor openings.
15. The pump normally runs hot. To avoid burns when servicing the pump,
allow it to cool for twenty minutes after shutdown before handling it.
16. Always check the pump before each operation. A damaged pump must
not be used. Have the pump serviced by a qualified service technician.
ELECTRICAL SAFETY
WARNING! Hazardous voltage can shock, burn or kill. When installing,
operating or servicing this pump, follow the safety instructions listed below.
1. Before installing this product, have the electrical circuit checked by an
electrician to ensure proper grounding.
2. Connect this product to a grounded circuit equipped with a Ground
Fault Circuit Interrupter (GFCI) device.
3. Do not install the pump in any location classified as hazardous by the
National Electrical Code, ANSI / NFPA 80-1984 or the Canadian Electrical
Code.
4. Do not allow the plug on the end of the electrical cord to be
submerged.
5. Do not use extension cords. They are a fire hazard and can reduce the
voltage sufficiently to prevent pumping and / or damage the motor.
6. Do not handle or service the pump while it is connected to the power
supply.
7. Ground the motor before connecting to an electrical supply.
8. Failure to ground the motor can cause severe or fatal electrical shock.
9. Do not ground to a gas supply line.
10. To avoid dangerous or fatal electrical shock, turn off the power to the
motor before working on electrical connections.
11. Check the voltage on the motor nameplate and make sure that the line
voltage of the electrical current supply is the same.
12. The supply voltage must be within 10% of the nameplate voltage.
Incorrect voltage can cause fire or seriously damage the motor and
voids the warranty. If in doubt, contact a licensed electrician.
13. Meet all national electrical code and local codes for all wiring.
14. Do not handle a pump or pump motor with wet hands, or when
standing on a wet or damp surface or in water.
8887184 1/3 HP Sump Pump V1.0
6 For technical questions call 1-800-665-8685
15. Always disconnect the power source before performing any work on or
near the motor or its connected load.
16. Protect yourself against electric shocks when working on electrical
equipment. Avoid body contact with grounded surfaces. There is an
increased chance of electrical shock if your body is grounded.
17. The fuse must be a residual current circuit-breaker with a measured
residual current of no more than 30 mA.
18. If the device is not in use, make sure that the plug is removed from the
power source.
19. Make sure that the device is switched off before plugging in the mains
cable.
20. Make sure that the device is switched off before unplugging it.
21. Disconnect the power supply before moving or transporting the device.
22. Do not install and switch on the pump if there are people or animals in
the medium, or have contact with the medium being pumped (such as
swimming pools).
WARNING! A qualified electrician should perform all wiring.
POWER CORD
1. Do not operate this tool if the power cord is frayed or damaged as an
electric shock may occur, resulting in personal injury or property
damage.
a. Inspect the tool's power cord for cracks, fraying or other faults in
the insulation or plug before each use.
b. Discontinue use if a power cord feels more than comfortably
warm while operating the tool.
c. Have the power cord replaced by a qualified service technician.
2. Keep all connections dry and off the ground to reduce the risk of
electric shock. Do not touch plug with wet hands.
3. Prevent damage to the power cord by observing the following:
a. Never use the cord to carry the tool.
b. Do not pull on the cord to disconnect the plug from an outlet.
c. Keep the power cord clear of the tool and the tool's work path
while in operation. The cord should always stay behind the tool.
d. Keep cord away from heat, oil, sharp edges or moving parts.
V1.0 1/3 HP Sump Pump 8887184
Visit www.princessauto.com for more information 7
4. Do not allow people, mobile equipment or vehicles to pass over
unprotected power cords.
a. Position power cords away from traffic areas.
b. Place cords in reinforced conduits.
c. Place planks on either side of the power cord to create a
protective trench.
UNPACKING
WARNING! Do not operate the tool if any part is missing. Replace the
missing part before operating. Failure to do so could result in a malfunction
and personal injury.
Remove the parts and accessories from the packaging and inspect for damage.
IDENTIFICATION KEY
A Carrying Handle
B Float Switch
C Pump Casing
D Discharge Outlet
ASSEMBLY & INSTALLATION
When this manual refers to a part number, it refers to the included Parts
Identification section.
HOSE CONNECTION
IMPORTANT! All threaded connections must be sealed with thread sealing
tape.
1. Connect the pressure pipe onto the pressure connection. For occasional
use, use a suitable water hose.
2. The use of rigid pipes with a non-return valve is recommended for use
at a fixed location. This prevents the return flow of liquid when
switching the pump off.
IMPORTANT! When using a hose, screw a suitable hose adapter onto the
pressure connection. Push the hose firmly onto the hose adapter and secure
with a hose clamp.
8887184 1/3 HP Sump Pump V1.0
8 For technical questions call 1-800-665-8685
LOCATION
1. The minimum diameter of the sump pit is 14 in. The minimum depth of
the pit is 16 in. The float switch must be able to move freely so that it
functions properly.
2. Make sure to locate the pump in a stable position (especially for
automatic operation).
3. Make sure that the pump is located in a way that ensures the inlet
openings at the suction base are unobstructed. Place the pump on a brick
or cement, do not place the pump directly on open earth or gravel.
4. Do not use the power cable or float switch to carry or hang the pump.
INSTALLATION
Tools Required for Assembly: Wrench, Phillips screwdriver.
1. The discharge port for this pump is 1-1/2 in. If a 1-1/4 in. discharge pipe
is already in place, wrap the threads of the included 1-1/4 in. adaptor
with sealant tape and thread into pump discharge port (Fig. 2-1).
2. Install a sump pump check valve (not included) into the pump (Fig. 3-1).
3. Connect a flexible connector (not included) to the check valve (Fig. 4-1).
Place the pump in the sump pit. Make sure the float switch operation is
not impaired by the connector.
4. Remove all small stones, gravel, mud, or other debris from the sump pit
before installing the pump.
5. A rigid discharge pipe is recommended to prevent the pump from
moving. If a flexible discharge hose is used, the pump must be secured
to prevent movement. The float switch could be trapped between a
moving pump and the sump wall, preventing the pump from turning on
or off.
6. Plug the pump into a GFCI outlet. The pump is now ready for use.
Fig. 2
Fig. 3
Fig. 4
V1.0 1/3 HP Sump Pump 8887184
Visit www.princessauto.com for more information 9
7. Check the pump by filling the sump pit with water
and observe the pump's operation through one
complete cycle and make sure the pump cannot
move in the sump pit and that the float switch
moves freely up and down (Fig. 5-1).
NOTICE! Do not adjust the tether length. The factory
has set the tether length to 4 inches. Altering the
length can result in pump failure.
OPERATION
1. Submerge the pump at an angle into the liquid to be pumped so that
no air pocket forms on the underside of the appliance. Suction would
be prevented by this air pocket. Once the pump is submerged, it can be
righted again.
2. Leave the pump on the bottom of the liquid source.
3. After the pump has been connected to the main power supply, the
pump will begin operating.
CAUTION! The float switch must be able to move so that the submersible
pump cannot run dry.
OPERATING TIPS
1. Dry-running operation causes increased wear and is to be avoided.
Therefore, the pump must be immediately switched off when water
fails to flow.
2. After having pumped chlorinated swimming pool water or other liquids
leaving residues, the pump should be rinsed with clean, clear water.
3. Sand and other abrasive materials in the liquid cause increased wear
and reduce the pumps output.
4. If the pump becomes air locked, shut the power off for approximately 1
minute then restart the pump. Repeat several times to clear the air
from the pump.
CARE & MAINTENANCE
WARNING! Disconnect the mains plug before carrying out any work on the
device.
WARNING! All gaskets must be replaced after each disassembly of
components.
Fig. 5
8887184 1/3 HP Sump Pump V1.0
10 For technical questions call 1-800-665-8685
1. Maintain the tool with care. A tool in good condition is efficient, easier
to control and will have fewer problems.
2. Make certain that the power source conforms to the requirements of
your equipment.
3. When wiring an electrically driven device, follow all electrical and
safety codes, as well as the most recent Canadian Electrical Code (CE)
and the Canadian Centre for Occupational Health and Safety (CCOHS).
4. Always disconnect the pump from the power source prior to repairs.
Always reconnect the pump to the power source after the repairs.
5. Inspect the tool fittings, alignment, hoses and power supply cord
periodically. Have damaged or worn components repaired or replaced
by an authorized technician. Only use identical replacement parts
when servicing.
6. Only use accessories intended for use with this tool.
7. Maintain the tools labels and name plates. These carry important
information. If unreadable or missing, contact Princess Auto Ltd. for
replacements.
WARNING! Only qualified service personnel should repair the tool. An
improperly repaired tool may present a hazard to the user and/or others.
CLEANING
Rinse with clean water. Remove stubborn contamination with a brush and
detergent. Submerge the pump in a container with clean water and switch
on for a short time to rinse the inside of the pump.
CLEANING THE SUCTION AREA
Clean all accessible insides of the casing. Remove fibres which have wound
around the rotor shaft by opening the pressure connection. Remove
stubborn contamination with a brush and detergent.
IMPORTANT! Before using the pump again, first soak the pump so that any
possible dirt residues do not block the appliance.
MAINTENANCE SCHEDULE
BEFORE EACH USE
1. Perform a visual inspection of the pump casing and cables for damage.
2. Check the float switch for damage by lifting and shaking the switch to
check the free movement of the contained metal balls.
V1.0 1/3 HP Sump Pump 8887184
Visit www.princessauto.com for more information 11
AFTER EVERY USE
Clean the pump thoroughly.
STORAGE
The pump should not be stored outside; the pump could get damaged from
rain and ice. Keep the pump in a cool, dry place. Do not store the pump in
direct sunlight.
REMOVAL FROM STORAGE
Before using the pump again, first soak the pump so that any possible dirt
residues do not block the appliance.
DISPOSAL
Recycle a tool damaged beyond repair at the appropriate facility.
TROUBLESHOOTING
Visit a Princess Auto Ltd. location for a solution if the tool does not function
properly or parts are missing. If unable to do so, have a qualified technician
service the tool.
Problem(s) Possible Cause(s) Suggested Solution(s)
Pump does not
run.
1. No power.
2. Motor overheats.
3. Ground Fault Circuit
Interrupter (GFCI) is
activated.
1. Check the cables, plug,
socket and fuse.
2a. Liquid temperature is too
high, eliminate the cause of
overheating.
2b. Blocked by foreign
contaminants, eliminate the
cause of overheating.
3. Switch on the GFCI, if it
happens again, contact a
qualified service technician.
Pump runs but
does not pump
liquids.
1. Suction opening is
blocked.
2. The pump draws in air.
3. The pump is blocked by
foreign contaminants.
1. Remove the blockage.
2a. Keep the pump at an angle
while submerging.
2b. Switch the pump on and off
several times in order to
expel the air.
3. Clean the pump.
8887184 1/3 HP Sump Pump V1.0
12 For technical questions call 1-800-665-8685
Problem(s) Possible Cause(s) Suggested Solution(s)
The delivery rate
is too low.
1. The delivery height is
too great.
2. The pressure line
diameter is too small.
3. The pressure line is
blocked.
4. The suction opening is
blocked.
5. The pressure line is
kinked.
6. The pressure line leaks.
1. Reduce the deliver
y height to
the maximum height (see
Specifications).
2. Use a pressure line with a
larger diameter.
3. Remove the blockage.
4. Remove the blockage.
5. Straighten the pressure line.
6. Seal the pressure line,
tighten the threaded
connections.
The pump runs
very loudly.
1. The pump is drawing in
air.
1a. Ensure there is sufficient
liquid present.
1b. Keep the pump at an angle
while submerging.
V1.0 1/3 HP Sump Pump 8887184
Visit www.princessauto.com for more information 13
PARTS BREAKDOWN
PARTS LIST
# DESCRIPTION QTY
1
Shaft 1
2
Impeller 1
3
Volute 1
4
Screw 7
8887184 1/3 HP Sump Pump V1.0
14 For technical questions call 1-800-665-8685
V1,0 8887184
Vous devez lire et comprendre toutes les instructions avant d'utiliser l'appareil.
Conservez ce manuel afin de pouvoir le consulter plus tard.
8887184 Pompe de puissard de 1/3 CV V1,0
2 En cas de questions techniques, appelez le 1-800-665-8685
SPÉCIFICATIONS
Puissance nominale 1/3 CV
Tension nominale / Courant nominal 115 V c.a. / 4,6 A
Cycle de service Continu
Taille de refoulement 1 1/2 po NPT avec adaptateur 1 1/4 po
Hauteur de refoulement max. 27 pi
Débit à 5 pi 2 840 gal/h
Débit à 10 pi 2 480 gal/h
Débit à 15 pi 2 050 gal/h
Débit à 20 pi 1 460 gal/h
Matériau Boîtier Thermoplastique
Impulseur Nylon
Volute Thermoplastique
Dim. (long x larg. x haut.) 7,9 à 7,9 à 10,8 po
Type de commutateur Interrupteur à cordon
Long. de cordon 10 pi
Température ambiante 40°C (104°F)
Température du liquide (°C) 25°C (77°F)
DÉFINITIONS DE DANGER
Veuillez-vous familiariser avec les avis de danger qui sont présentés dans ce
manuel. Un avis est une alerte indiquant qu'il existe un risque de dommage à la
propriété, de blessure ou de décès si on ne respecte pas certaines instructions.
DANGER ! Cet avis indique un risque immédiat et particulier qui
entraînera des blessures corporelles graves ou même la
mort si on omet de prendre les précautions nécessaires.
AVERTISSEMENT ! Cet avis indique un risque particulier ou une pratique non
sécuritaire qui
pourrait entraîner des blessures corporelles
graves ou même la mort si on omet de prendre les
précautions nécessaires.
ATTENTION ! Cet avis indique une situation possiblement dangereuse qui
peut entraîner des blessures mineures ou modérées si on ne
procède pas de la façon recommandée.
AVIS ! Cet avis indique un risque particulier ou une pratique non
sécuritaire qui entraînera des dommages au niveau de
l'équipement ou des biens, mais non des blessures corporelles.
V1,0 Pompe de puissard de 1/3 CV 8887184
Visitez www.princessauto.com pour plus d'informations 3
SÉCURITÉ
AVERTISSEMENT ! Veuillez lire et comprendre toutes les instructions avant
d'utiliser cet outil. L'utilisateur doit respecter les précautions de base
lorsqu'il utilise cet outil afin de réduire le risque de blessure ou de
dommage à l'équipement.
Conservez ce manuel qui contient les avertissements de sécurité, les
précautions, les instructions de fonctionnement ou d'inspection et d'entretien.
AIRE DE TRAVAIL
1. Travaillez dans un environnement de travail sécuritaire. Gardez votre
aire de travail propre, bien éclairée et exempte de toute distraction.
Placez les lampes de façon à ne pas travailler dans lombre.
2. Assurez-vous que les personnes qui ne portent pas l'équipement de
sécurité approprié ne se trouvent pas à proximité de l'aire de travail.
3. Rangez les outils correctement dans un lieu sécurisé et sec. Gardez les
outils hors de la portée des enfants.
4. N'installez pas et n'utilisez pas d'outils électriques en présence de gaz,
de poussière ou de liquides inflammables.
SÉCURITÉ PERSONNELLE
AVERTISSEMENT ! Portez de l'équipement de protection personnelle
homologué par l'Association canadienne de normalisation (CSA) ou
l'American National Standards Institute (ANSI).
ÉQUIPEMENT DE PROTECTION PERSONNELLE
1. Portez toujours des lunettes antiprojections qui offrent une protection
frontale et latérale pour les yeux. L'équipement de protection des yeux
devrait être conforme à la norme CSA Z94.3-07 ou ANSI Z87.1 fonction
du type de travail effectué.
2. Portez des gants qui protègent en fonction des matériaux de travail et
pour réduire les effets des vibrations de l'outil.
3. Portez des vêtements de protection conçus pour l'environnement de
travail et pour l'outil.
4. Les chaussures antidérapantes sont recommandées pour maintenir la
stabilité et l'équilibre au sein de l'environnement de travail.
5. Portez un appareil respiratoire approuvé par la NIOSH pour travailler
sur des matériaux qui produisent des émanations dangereuses, de la
poussière ou des particules.
8887184 Pompe de puissard de 1/3 CV V1,0
4 En cas de questions techniques, appelez le 1-800-665-8685
PRÉCAUTIONS PERSONNELLES
Gardez le contrôle de l'outil, de vos mouvements et de l'environnement de
travail pour éviter les blessures ou le bris de l'outil.
1. N'utilisez pas l'outil si vous êtes fatigué ou sous l'effet de drogues,
d'alcool ou de médicaments.
2. Évitez de porter des vêtements ou des bijoux pouvant se prendre dans
les pièces mobiles d'un outil. Gardez les cheveux longs recouverts ou
attachés.
3. N'utilisez pas l'outil si vous devez étirer les bras pour vous en servir.
Une stabilité et un équilibre appropriés sont nécessaires afin d'avoir un
meilleur contrôle en cas de situations inattendues.
CONSIGNES DE SÉCURITÉ SPÉCIFIQUES
DANGER ! Ne permettez PAS au confort ou à votre familiarisation avec l'outil
(obtenus après un emploi répété) de se substituer à une adhésion stricte aux
règles de sécurité de l'outil. Si vous utilisez cet outil de façon dangereuse ou
incorrecte, vous pouvez subir des blessures corporelles graves.
1. Utilisez le bon outil pour la tâche à effectuer. Cet outil a été conçu pour
une utilisation spécifique. Évitez de modifier ou d'altérer cet outil ou de
l'utiliser à une fin autre que celle pour laquelle il a été conçu.
2. N'utilisez pas l'outil si des pièces sont endommagées, cassées ou
égarées. Réparer ou remplacer les pièces.
3. Ne faites pas fonctionner la pompe s'il n'y a pas d'eau dans le système.
4. N'utilisez pas les pompes dans une eau dont la température est
supérieure à 40 °C (104 °F). Évitez de vider les réservoirs d'eau chaude
dans les puisards.
5. N'alimentez pas cet appareil avec toute source d'énergie autre qu'une
alimentation de 120 V.
6. N'utilisez pas les pompes afin de pomper de la boue, du sable, du
ciment, des graisses, du sel, les eaux usées des toilettes, des huiles,
des substances combustibles ou explosives ou des produits chimiques.
7. L'appareil a pour but de pomper l'eau de pluie, l'eau douce, l'eau de
conduite principale ainsi que l'eau de piscine chlorée.
8. La pompe ne doit pas être utilisée pour pomper de l'eau potable ou
pour acheminer des produits alimentaires.
9. L'appareil ne convient pas à un usage industriel ou commercial.
V1,0 Pompe de puissard de 1/3 CV 8887184
Visitez www.princessauto.com pour plus d'informations 5
10. Risque d'incendie ou d'explosion. Ne pompez pas des liquides
inflammables ou explosifs comme l'essence, le carburant, l'huile, le
kérosène, etc.
11. Ne soulevez pas la pompe au moyen du cordon d'alimentation.
12. Assurez-vous que la source d'énergie de la pompe est déconnectée
avant d'installer ou d'entretenir la pompe.
13. N'exposez pas la pompe aux températures de congélation. Le gel
pourrait causer des dommages graves, ce qui annulera la garantie.
14. N'introduisez pas de doigt ou d'objet dans les orifices de la pompe ou
du moteur.
15. La pompe est normalement chaude lorsqu'elle est en marche. Pour
éviter les brûlures lors de l'entretien de la pompe, laissez-la refroidir
pendant 20 minutes après l'arrêt avant sa manutention.
16. Vérifiez toujours la pompe avant chaque utilisation. Évitez d'utiliser la
pompe si elle est endommagée. Confiez l'entretien de la pompe à un
technicien de service qualifié.
SÉCURITÉ EN ÉLECTRICITÉ
AVERTISSEMENT ! Les tensions dangereuses peuvent électrocuter, brûler ou
causer la mort. Lors de l'installation, de l'utilisation ou de l'entretien de
cette pompe, observez les instructions de sécurité énoncées ci-dessous.
1. Avant d'installer ce produit, faites vérifier le circuit électrique par un
électricien afin d'assurer une mise à la masse efficace.
2. Évitez que la fiche à l'extrémité du cordon d'alimentation ne soit
submergée.
3. Reliez ce produit à un circuit à la masse muni d'un dispositif de
disjoncteur de fuite à la terre (GFCI).
4. N'installez pas la pompe dans un endroit qualifié de dangereux dans le
Code électrique national, dans la norme ANSI/NFPA 80-1984 ou dans le
Code canadien de l'électricité.
5. N'utilisez pas de rallonges de câble. Ils constituent un risque d'incendie
et peuvent réduire la tension suffisamment pour empêcher le pompage
ou endommager le moteur.
6. Ne tentez pas de manipuler ou d'entretenir la pompe alors qu'elle est
reliée à une source d'énergie.
7. Placez le moteur à la masse avant de le brancher à une source
d'énergie.
8887184 Pompe de puissard de 1/3 CV V1,0
6 En cas de questions techniques, appelez le 1-800-665-8685
8. À défaut de mettre le moteur à la masse, il peut en résulter un choc
électrique grave ou même fatal.
9. Ne mettez pas le moteur à la masse en le connectant à une conduite
d'alimentation de gaz.
10. Pour éviter un choc électrique dangereux ou fatal, coupez l'alimentation au
niveau du moteur avant de travailler sur les connexions électriques.
11. Vérifiez la tension sur la plaque signalétique du moteur et assurez-vous
que la tension de ligne de l'alimentation en courant est identique.
12. La tension d'alimentation électrique doit se situer à 10 % près de la
tension indiquée sur la plaque signalétique. Une tension incorrecte
peut causer un incendie ou des dommages graves au moteur, annulant
ainsi la garantie. En cas de doute, contactez un électricien qualifié.
13. Respectez les exigences de tout le Code national électrique et des
codes locaux pour tout le câblage.
14. Évitez de manier la pompe ou le moteur de pompe avec les mains humides
ou si vous vous trouvez sur une surface humide ou moite ou dans l'eau.
15. Coupez toujours la source d'énergie avant d'effectuer tout travail sur
ou près du moteur ou de sa charge branchée.
16. Progez-vous contre les chocs électriques lorsque vous travaillez en
présence d'équipement électrique. Évitez que le corps entre en contact
avec des surfaces mises à la terre. Il y a un risque plus élevé de choc
électrique si votre corps est mis à la terre.
17. Le fusible doit être un disjoncteur présentant un courant résiduel
mesuré ne dépassant pas 30 mA.
18 Si l'appareil n'est pas utilisé, assurez-vous que la fiche a été retirée de
la source d'énergie.
19. Assurez-vous de placer l'appareil hors tension avant de brancher le
câble de secteur.
20. Assurez-vous de placer l'appareil hors tension avant de le débrancher.
21. Débranchez la source d'alimentation avant de déplacer ou de
transporter l'appareil.
22. N'installez et n'actionnez pas la pompe si des personnes ou des
animaux se trouvent dans la source de liquide ou sont en contact avec
la source de liquide pompée (comme une piscine).
AVERTISSEMENT ! Un électricien qualifié devrait procéder à toutes les
opérations de câblage.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Power Fist 8887184 Le manuel du propriétaire

Taper
Le manuel du propriétaire

dans d''autres langues