Hatco HZMH, HZMH-xxD, HZMS, HZMS-xxD Series Le manuel du propriétaire

Taper
Le manuel du propriétaire
P/N 07.04.569.00 © 2016 Hatco Corporation
Heated Zone Merchandisers
Les comptoirs chauffants
HZMH and HZMS Series/Série
Installation and Operating Manual
Manuel d’installation et d’utilisation
hatcocorp.com
Register Online!
(see page 2)
S’inscrire en ligne!
(voir page 21)
Do not operate this equipment unless you
have read and understood the contents
of this manual! Failure to follow the
instructions contained in this manual
may result in serious injury or death.
This manual contains important safety
information concerning the maintenance,
use, and operation of this product. If
you’re unable to understand the contents
of this manual, please bring it to the
attention of your supervisor. Keep this
manual in a safe location for future
reference.
English = p 2
WARNING
No opere este equipo al menos que haya
leído y comprendido el contenido de este
manual! Cualquier falla en el seguimiento
de las instrucciones contenidas en
este manual puede resultar en un serio
lesión o muerte. Este manual contiene
importante información sobre seguridad
concerniente al mantenimiento, uso y
operación de este producto. Si usted
no puede entender el contenido de
este manual por favor pregunte a su
supervisor. Almacenar este manual en
una localización segura para la referencia
futura.
ADVERTENCIA
Ne pas utiliser cet équipement sans avoir
lu et compris le contenu de ce manuel ! Le
non-respect des instructions contenues
dans ce manuel peut entraîner de
graves blessures ou la mort. Ce manuel
contient des informations importantes
concernant l’entretien, l’utilisation et le
fonctionnement de ce produit. Si vous ne
comprenez pas le contenu de ce manuel,
veuillez le signaler à votre supérieur.
Conservez ce manuel dans un endroit
sûr pour pouvoir vous y référer plus tard.
Français = p 21
AVERTISSEMENT
Form No. HZMM-1116
2
English
Safety information that appears in this manual is identified by
the following signal word panels:
WARNING
WARNING indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury.
NOTICE
NOTICE
is used to address practices not related to personal
injury.
INTRODUCTION
Hatco Heated Zone Merchandisers with Spot On
®
technology
are perfect for holding hot packaged food in convenience
stores, on a buffet line, or at temporary serving areas. Spot-On
technology senses when product is placed in a zone on a shelf,
activating the overhead heat and base heat. The instant-on,
individually-zoned overhead ribbon elements are combined
with heated shelves that have separate front and rear heating
elements to significantly reduce energy consumption. Hot
wrapped products are kept at optimum serving temperatures
without affecting quality. These units feature an LCD controller,
LED lighting on each shelf, and come with a cord and plug set.
Hatco Heated Zone Merchandisers are products of extensive
research and field testing. The materials used were selected
for maximum durability, attractive appearance, and optimum
performance. Every unit is inspected and tested thoroughly
prior to shipment.
This manual provides the installation, safety, and operating
instructions for Heated Zone Merchandisers. Hatco
recommends all installation, operating, and safety instructions
appearing in this manual be read prior to installation or
operation of the warmer.
Important Owner Information ..............................................2
Introduction ...........................................................................2
Important Safety Information ..............................................3
Model Description ................................................................4
All Models ............................................................................ 4
HZMH-XX and HZMH-XXD Models ....................................4
HZMS-XX and HZMS-XXD Models .....................................4
Model Designation ...............................................................4
Specifications .......................................................................5
Plug Configurations .............................................................5
Electrical Rating Charts ....................................................... 5
Factory Setpoints — Horizontal Shelf Models .....................6
Factory Setpoints — Slanted Shelf Models .........................6
Overall Dimensions — HZMH Models ................................7
Overall Dimensions — HZMS Models .................................8
Shelf and Zone Dimensions ................................................9
Overhead Zone Identification ..............................................9
Installation ...........................................................................10
General .............................................................................. 10
Operation ............................................................................. 11
General .............................................................................. 11
Changing Shelf Setpoint Temperature and
Operating Mode ...............................................................12
Changing Element Power Percentages ............................13
Changing Between Fahrenheit and Celsius ...................... 14
LCD Controller Flow Chart — Horizontal Shelf Models ....15
LCD Controller Flow Chart — Slanted Shelf Models ........16
Maintenance ........................................................................17
General .............................................................................. 17
Daily Cleaning ...................................................................17
Troubleshooting Guide ......................................................18
Options and Accessories ..................................................19
Limited Warranty ................................................................20
Authorized Parts Distributors ...........................Back Cover
IMPORTANT OWNER INFORMATION
Record the model number, serial number, voltage, and purchase
date of the unit in the spaces below (specification label
located on the side of the control enclosure). Please have this
information available when calling Hatco for service assistance.
Model No. ________________________________________
Serial No. _________________________________________
Voltage ___________________________________________
Date of Purchase ___________________________________
Register your unit!
Completing online warranty registration will prevent delay in
obtaining warranty coverage. Access the Hatco website at
www.hatcocorp.com, select the Parts & Service pull-down
menu, and click on “Warranty Registration”.
Business
Hours: 7:00 am to 5:00 pm Central Standard Time (CST)
(Summer Hours: June to September
7:00 am to 5:00 pm CST MondayThursday
7:00 am to 4:00 pm CST Friday)
Telephone: 800-558-0607; 414-671-6350
24 Hour 7 Day Parts and Service
Assistance available in the United States
and Canada by calling 800-558-0607.
Additional information can be found by visiting our web site at
www.hatcocorp.com.
CONTENTS
Form No. HZMM-1116
3
English
IMPORTANT SAFETY INFORMATION
WARNING
Do not place food product directly onto hardcoat surface.
Food product must be wrapped, boxed, or on a food pan.
Make sure all operators have been instructed on the safe
and proper use of the unit.
This unit is not intended for use by children or persons
with reduced physical, sensory, or mental capabilities.
Ensure proper supervision of children and keep them
away from the unit.
This unit has no “user-serviceable” parts. If service
is required on this unit, contact an Authorized Hatco
Service Agent or contact the Hatco Service Department at
800-558-0607 or 414-671-6350.
CAUTION
BURN HAZARD: Some exterior surfaces on unit will get
hot. Use caution when touching these areas.
Locate unit at proper counter height in an area that is
convenient for use. Location should be level to prevent
unit or its contents from falling accidentally and strong
enough to support the weight of the unit and contents.
Do not move or relocate unit for cleaning. Unit is bulky
and heavy.
NOTICE
Do not lay unit on front or back side. Damage to unit could
occur.
Use non-abrasive cleaners and cloths only. Abrasive
cleaners and cloths could scratch finish of unit, marring its
appearance and making it susceptible to soil accumulation.
IMPORTANT—DO NOT use paper towel or glass cleaner
to clean plastic surfaces such as sneeze guards and
flip-up doors. Paper towel and glass cleaner may scratch
the material. Wipe off plastic surfaces using a soft, clean,
water-dampened cloth.
Do not slide pans across hardcoat surface, use rough-
bottomed pans, or drop anything on hardcoat surface.
Scratching may occur. Damage to hardcoat surface
caused by misuse is not covered under warranty.
Clean unit daily to avoid malfunctions and maintain
sanitary operation.
Do not locate unit in area with excessive air movement
around unit. Avoid areas that may be subject to active air
movements or currents (i.e., near exhaust fans/hoods, air
conditioning ducts, and exterior doors).
WARNING
ELECTRIC SHOCK HAZARD:
Plug unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. If
plug and receptacle do not match, contact a qualified
electrician to determine and install proper voltage and
size electrical receptacle.
Turn OFF power switch, unplug power cord, and allow
unit to cool before performing any cleaning, setup, or
maintenance.
DO NOT submerge or saturate with water. Unit is not
waterproof. Do not operate if unit has been submerged
or saturated with water.
Unit is not weatherproof. Locate unit indoors where
ambient air temperature is a minimum of 70°F (21°C).
• Do not steam clean or use excessive water on unit.
This unit is not “jet-proof” construction. Do not use
jet-clean spray to clean this unit.
• Do not clean unit when it is energized or hot.
• Do not pull unit by power cord.
• Discontinue use if power cord is frayed or worn.
Do not attempt to repair or replace a damaged power
cord. Cord must be replaced by Hatco, an Authorized
Hatco Service Agent, or a person with similar
qualifications.
This unit must be serviced by qualified personnel only.
Service by unqualified personnel may lead to electric
shock or burn.
Use only Genuine Hatco Replacement Parts when
service is required. Failure to use Genuine Hatco
Replacement Parts will void all warranties and may
subject operators of the equipment to hazardous
electrical voltage, resulting in electrical shock or burn.
Genuine Hatco Replacement Parts are specified to
operate safely in the environments in which they are
used. Some aftermarket or generic replacement parts
do not have the characteristics that will allow them to
operate safely in Hatco equipment.
FIRE HAZARD: Install unit with a minimum of 3″ (76 mm) of
space from rear of unit to a back wall. If safe distances are
not maintained, discoloration or combustion could occur.
Make sure food product has been heated to the proper
food-safe temperature before placing in unit. Failure to
heat food product properly may result in serious health
risks. This unit is for holding pre-heated food product only.
Read the following important safety information before using this equipment to avoid
serious injury or death and to avoid damage to equipment or property
.
Form No. HZMM-1116
4
English
MODEL DESCRIPTION
MODEL DESIGNATION
All Models
All Hatco Heated Zone Merchandisers are perfect for holding
hot packaged food in convenience stores, on a buffet line, or
at temporary serving areas. Hot wrapped products are kept
at optimum serving temperatures without affecting quality.
Instant-on, individually-zoned overhead ribbon heating elements
are combined with heated shelves that have separate front and
rear heating elements to significantly reduce energy consumption.
Other features include an LCD controller, LED lighting above each
shelf, product divider rods, hinged glass side panels, and a 6′
(1829 mm) cord and plug set. Heated Zone Merchandisers come
standard in black and are available in several Designer colors.
HZMH-XX and HZMH-XXD Models
HZMH models are horizontal shelf merchandisers designed to
hold hot wrapped product. They are available in widths from
24″ to 60 (610 to 1524 mm) in six inch (152 mm) increments
and are available in single or dual shelf models.
HZMH Models
HZMS-XX and HZMS-XXD Models
The HZMS models are slanted shelf merchandisers designed
to hold hot wrapped product. The shelves are slanted for the
convenience of self-service. They are available in widths from
24″ to 60″ (610 to 1524 mm) in six inch (152 mm) increments
and are available in single or dual shelf models.
HZMS Models
NOTE: Sneeze guards and flip-up doors are available
for the Heated Zone Merchandisers. Refer to the
OPTIONS AND ACCESSORIES section in this manual
for details.
H Z M X - X X D
Heated Zone Merchandiser
Heated Width of Unit (inches)
No Character = Single Shelf
D = Dual Shelf
H = Horizontal Shelf
S = Slanted Shelf
Form No. HZMM-1116
5
English
Model Voltage Watts Amps
Overhead
Zones Plug Configuration
HZMH-24D 120 1500 12.5 4 NEMA 5-20P
HZMH-30D 120/208–240 2700 11.3 8 NEMA L14-20P
HZMH-36D 120/208–240 2800 11.7 8 NEMA L14-20P
HZMH-42D 120/208–240 2900 12.1 8 NEMA L14-20P
HZMH-48D 120/208–240 3000 12.6 8 NEMA L14-20P
HZMH-54D 120/208–240 4200 17.6 12 NEMA L14-30P
HZMH-60D 120/208–240 4300 18.0 12 NEMA L14-30P
Model Voltage Watts Amps
Overhead
Zones Plug Configuration
HZMH-24 120 750 6.3 2 NEMA 5-15P
HZMH-30 120 1350 11.3 4 NEMA 5-15P
HZMH-36 120 1400 11.7 4 NEMA 5-15P
HZMH-42 120 1450 12.1 4 NEMA 5-20P
HZMH-48 120 1500 12.5 4 NEMA 5-20P
HZMH-54 120 2100 17.5 6 NEMA 5-30P
HZMH-60 120 2150 17.9 6 NEMA 5-30P
SPECIFICATIONS
Electrical Rating Chart — HZMH-XX Models (Horizontal Single Shelf)
Electrical Rating Chart — HZMH-XXD Models (Horizontal Dual Shelf)
Plug Configurations
Units are equipped with an electrical cord and plug appropriate
for the electrical rating of the unit and must be connected to a
dedicated circuit.
WARNING
ELECTRIC SHOCK HAZARD: Plug unit into a properly
grounded electrical receptacle of the correct voltage,
size, and plug configuration. If plug and receptacle do not
match, contact a qualified electrician to determine and
install proper voltage and size electrical receptacle.
NOTE: The specification label is located on the side of the
control enclosure. See the label for the serial number
and verification of unit electrical information.
NEMA 5-15P NEMA 5-20P
NEMA L14-20P
NEMA L14-30P
NEMA 5-30P
Plug Configurations
NOTE: Receptacle not supplied by Hatco.
Form No. HZMM-1116
6
English
Model Voltage Watts Amps
Overhead
Zones Plug Configuration
HZMS-24D 120 1500 12.5 4 NEMA 5-20P
HZMS-30D 120/208–240 2700 11.3 8 NEMA L14-20P
HZMS-36D 120/208–240 2800 11.7 8 NEMA L14-20P
HZMS-42D 120/208–240 2900 12.1 8 NEMA L14-20P
HZMS-48D 120/208–240 3000 12.6 8 NEMA L14-20P
HZMS-54D 120/208–240 4200 17.6 12 NEMA L14-30P
HZMS-60D 120/208–240 4300 18.0 12 NEMA L14-30P
Model Voltage Watts Amps
Overhead
Zones Plug Configuration
HZMS-24 120 750 6.3 2 NEMA 5-15P
HZMS-30 120 1350 11.3 4 NEMA 5-15P
HZMS-36 120 1400 11.7 4 NEMA 5-15P
HZMS-42 120 1450 12.1 4 NEMA 5-20P
HZMS-48 120 1500 12.5 4 NEMA 5-20P
HZMS-54 120 2100 17.5 6 NEMA 5-30P
HZMS-60 120 2150 17.9 6 NEMA 5-30P
SPECIFICATIONS
Electrical Rating Chart — HZMS-XX Models (Slanted Single Shelf)
Electrical Rating Chart — HZMS-XXD Models (Slanted Dual Shelf)
Factory Setpoints—Slanted Shelf Models
Slanted shelf models are pre-set at the factory to the following
setpoints. The setpoints are the same for each shelf on dual
units.
Hardcoat Shelf Heating Elements:
Setpoint Temperature = 180°F (82°C)
Stand-By Power Percentage:
Front Element = 50% of full wattage
Rear Element = 0% of full wattage
Overhead Ribbon Heating Elements
Power Percentage:
Front Element = 75% of full wattage
Rear Element = 50% of the front overhead heating element’s
Power Percentage.
Factory Setpoints—Horizontal Shelf Models
Horizonal shelf models are pre-set at the factory to the following
setpoints. The setpoints are the same for each shelf on dual
units.
Hardcoat Shelf Heating Elements:
Setpoint Temperature = 180°F (82°C)
Stand-By Power Percentage = 50% of full wattage
Overhead Ribbon Heating Elements
Power Percentage = 75% of full wattage
Form No. HZMM-1116
7
English
Model
Width
(A)
Depth
(B)
Height
(C)
Footprint
Width (D)
Footprint
Depth (E)
Shelf
Height (F)
Control Box
Width (G)
HZMH-24 26-11/16
(677 mm)
28-9/16
(725 mm)
21-7/8
(555 mm)
27-15/16
(709 mm)
19
(483 mm)
9-1/2
(242 mm)
18
(457 mm)
HZMH-30 32-11/16
(829 mm)
28-9/16
(725 mm)
21-7/8
(555 mm)
33-15/16
(861 mm)
19
(483 mm)
9-1/2
(242 mm)
18
(457 mm)
HZMH-36 38-11/16
(982 mm)
28-9/16
(725 mm)
21-7/8
(555 mm)
39-15/16
(1013 mm)
19
(483 mm)
9-1/2
(242 mm)
18
(457 mm)
HZMH-42 44-11/16
(1134 mm)
28-9/16
(725 mm)
21-7/8
(555 mm)
45-15/16
(1166 mm)
19
(483 mm)
9-1/2
(242 mm)
18
(457 mm)
HZMH-48 50-11/16
(1286 mm)
28-9/16
(725 mm)
21-7/8
(555 mm)
51-15/16
(1318 mm)
19
(483 mm)
9-1/2
(242 mm)
18
(457 mm)
HZMH-54 56-11/16
(1439 mm)
28-9/16
(725 mm)
21-7/8
(555 mm)
57-15/16
(1471 mm)
19
(483 mm)
9-1/2
(242 mm)
18
(457 mm)
HZMH-60 62-11/16
(1591 mm)
28-9/16
(725 mm)
21-7/8
(555 mm)
63-15/16
(1623 mm)
19
(483 mm)
9-1/2
(242 mm)
18
(457 mm)
HZMH-24D 26-11/16
(677 mm)
28-9/16
(725 mm)
32-7/8
(835 mm)
27-15/16
(709 mm)
19
(483 mm)
9-1/2
(242 mm)
18
(457 mm)
HZMH-30D 32-11/16
(829 mm)
28-9/16
(725 mm)
32-7/8
(835 mm)
33-15/16
(861 mm)
19
(483 mm)
9-1/2
(242 mm)
18
(457 mm)
HZMH-36D 38-11/16
(982 mm)
28-9/16
(725 mm)
32-7/8
(835 mm)
39-15/16
(1013 mm)
19
(483 mm)
9-1/2
(242 mm)
18
(457 mm)
HZMH-42D 44-11/16
(1134 mm)
28-9/16
(725 mm)
32-7/8
(835 mm)
45-15/16
(1166 mm)
19
(483 mm)
9-1/2
(242 mm)
18
(457 mm)
HZMH-48D 50-11/16
(1286 mm)
28-9/16
(725 mm)
32-7/8
(835 mm)
51-15/16
(1318 mm)
19
(483 mm)
9-1/2
(242 mm)
18
(457 mm)
HZMH-54D 56-11/16
(1439 mm)
28-9/16
(725 mm)
32-7/8
(835 mm)
57-15/16
(1471 mm)
19
(483 mm)
9-1/2
(242 mm)
18
(457 mm)
HZMH-60D 62-11/16
(1591 mm)
28-9/16
(725 mm)
32-7/8
(835 mm)
63-15/16
(1623 mm)
19
(483 mm)
9-1/2
(242 mm)
18
(457 mm)
SPECIFICATIONS
Overall Dimensions — HZMH Models
HZMH — Single Shelf
Front
View
Side
View
Front View
Side View
HZMH — Dual Shelf
A
D
E
D
E
B
C
F
F
F
A B
C
G
G
Form No. HZMM-1116
8
English
Model
Width
(A)
Depth
(B)
Height
(C)
Footprint
Width (D)
Footprint
Depth (E)
Shelf
Height (F)
Control Box
Width (G)
HZMS-24 26-11/16
(677 mm)
28-3/16
(715 mm)
21-3/4
(551 mm)
27-15/16
(709 mm)
19
(483 mm)
9-5/16
(237 mm)
18
(457 mm)
HZMS-30 32-11/16
(829 mm)
28-3/16
(715 mm)
21-3/4
(551 mm)
33-15/16
(861 mm)
19
(483 mm)
9-5/16
(237 mm)
18
(457 mm)
HZMS-36 38-11/16
(982 mm)
28-3/16
(715 mm)
21-3/4
(551 mm)
39-15/16
(1013 mm)
19
(483 mm)
9-5/16
(237 mm)
18
(457 mm)
HZMS-42 44-11/16
(1134 mm)
28-3/16
(715 mm)
21-3/4
(551 mm)
45-15/16
(1166 mm)
19
(483 mm)
9-5/16
(237 mm)
18
(457 mm)
HZMS-48 50-11/16
(1286 mm)
28-3/16
(715 mm)
21-3/4
(551 mm)
51-15/16
(1318 mm)
19
(483 mm)
9-5/16
(237 mm)
18
(457 mm)
HZMS-54 56-11/16
(1439 mm)
28-3/16
(715 mm)
21-3/4
(551 mm)
57-15/16
(1471 mm)
19
(483 mm)
9-5/16
(237 mm)
18
(457 mm)
HZMS-60 62-11/16
(1591 mm)
28-3/16
(715 mm)
21-3/4
(551 mm)
63-15/16
(1623 mm)
19
(483 mm)
9-5/16
(237 mm)
18
(457 mm)
HZMS-24D 26-11/16
(677 mm)
28-3/16
(715 mm)
32-3/4
(831 mm)
27-15/16
(709 mm)
19
(483 mm)
9-5/16
(237 mm)
18
(457 mm)
HZMS-30D 32-11/16
(829 mm)
28-3/16
(715 mm)
32-3/4
(831 mm)
33-15/16
(861 mm)
19
(483 mm)
9-5/16
(237 mm)
18
(457 mm)
HZMS-36D 38-11/16
(982 mm)
28-3/16
(715 mm)
32-3/4
(831 mm)
39-15/16
(1013 mm)
19
(483 mm)
9-5/16
(237 mm)
18
(457 mm)
HZMS-42D 44-11/16
(1134 mm)
28-3/16
(715 mm)
32-3/4
(831 mm)
45-15/16
(1166 mm)
19
(483 mm)
9-5/16
(237 mm)
18
(457 mm)
HZMS-48D 50-11/16
(1286 mm)
28-3/16
(715 mm)
32-3/4
(831 mm)
51-15/16
(1318 mm)
19
(483 mm)
9-5/16
(237 mm)
18
(457 mm)
HZMS-54D 56-11/16
(1439 mm)
28-3/16
(715 mm)
32-3/4
(831 mm)
57-15/16
(1471 mm)
19
(483 mm)
9-5/16
(237 mm)
18
(457 mm)
HZMS-60D 62-11/16
(1591 mm)
28-3/16
(715 mm)
32-3/4
(831 mm)
63-15/16
(1623 mm)
19
(483 mm)
9-5/16
(237 mm)
18
(457 mm)
SPECIFICATIONS
Overall Dimensions — HZMS Models
Form No. HZMM-1116
9
English
Model
Interior Shelf
Width (A)
Zone
Width (B)
24 Models
24
(610 mm)
20-1/16
(510 mm)
30 Models
30
(762 mm)
12-5/16
(314 mm)
36 Models
36
(914 mm)
15-5/16
(390 mm)
42 Models
42
(1067 mm)
18-5/16
(465 mm)
48 Models
48
(1219 mm)
21-5/16
(543 mm)
54 Models
54
(1372 mm)
15-13/16
(402 mm)
60 Models
60
(1524 mm)
17-13/16
(453 mm)
SPECIFICATIONS
Zone Divider
Sensor Location
Sensor Location
Sensor Location
Sensor Location
Sensor Location
Sensor Location
Sensor Location
Sensor Location
Zone
1
Zone
2
Zone
4
Zone
3
Front of Unit
Rear of Unit
Zone numbering starts at the front left side,
goes front-to-back, then moves
to the right and continues front-to-back.
Overhead Zone Identification
Shelf and Zone Dimensions
Top View of Shelf for Overhead Zone Identification (four zone shelf shown)
A
B
A
Overhead View of Shelf
B
21-3/4"
(552 mm)
Shelf and Zone Dimensions
NOTE:24″(610mm)modelsdonothaveazonedivider.
30″to48″(762–1219mm)modelshaveasingle
zone divider. 54″ and 60″ (1372 and 1524 mm)
models have two zone dividers.
Form No. HZMM-1116
10
English
INSTALLATION
General
Hatco Heated Zone Merchandisers are shipped with most
components pre-assembled. Care should be taken when
unpacking shipping carton to avoid damage to the unit and
components enclosed.
WARNING
ELECTRIC SHOCK HAZARD: Unit is not weatherproof.
Locate unit indoors where ambient air temperature is a
minimum of 70°F (21°C).
FIRE HAZARD: Install unit with a minimum of 3″ (76 mm) of
space from rear of unit to a back wall. If safe distances are
not maintained, discoloration or combustion could occur.
CAUTION
Locate unit at proper counter height in an area that is
convenient for use. Location should be level to prevent
unit or its contents from falling accidentally and strong
enough to support the weight of the unit and contents.
NOTICE
Do not lay unit on front or back side. Damage to unit could
occur.
Do not locate unit in area with excessive air movement
around unit. Avoid areas that may be subject to active air
movements or currents (i.e., near exhaust fans/hoods, air
conditioning ducts, and exterior doors).
NOTE: Due to the size and weight of Heated Zone
Merchandisers, installation of a unit will require two or
more people.
1. Remove the unit from the carton.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
IMPORTANT OWNER INFORMATION section for
details.
2. Remove tape and protective packaging from all surfaces
of the unit.
3. Place the unit in the desired location.
Locate the unit in an area where the ambient air
temperature is constant and a minimum of 70° F
(21° C). Avoid areas that may be subject to active air
movements or currents (i.e., near exhaust fans/hoods,
air conditioning ducts, and exterior doors).
Make sure the unit is at the proper counter height in an
area convenient for use.
• Make sure the countertop is level and strong enough to
support the weight of the unit and food product.
Make sure the feet on the bottom of the unit are
positioned securely on the countertop.
4. Install the product divider rods into the channel dividers,
if desired. The rods can be adjusted easily to separate
holding areas as needed.
Product Divider Rod
Channel Divider
Glass Side Panel
swung open.
Installing Product Divider Rods
5. Install any accessories that came with the unit. Refer to the
OPTIONS AND ACCESSORIES section for details.
6. Plug the unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. See the
SPECIFICATIONS section for details.
Form No. HZMM-1116
11
English
OPERATION
General
Heated Zone Merchandisers are setup at the factory for
energy-saving, automatic operation (Sensors ON operation).
Refer to “Factory Setpoints” in the SPECIFICATIONS section
for factory setpoint information. Use the following information
and procedures to operate a Heated Zone Merchandiser.
WARNING
Read all safety messages in the IMPORTANT SAFETY
INFORMATION section before operating this equipment.
Do not place food product directly onto hardcoat surface.
Food product must be wrapped, boxed, or on a food pan.
NOTICE
Do not slide pans across hardcoat surface, use rough-
bottomed pans, or drop anything on hardcoat surface.
Scratching may occur. Damage to hardcoat surface
caused by misuse is not covered under warranty.
Theory of Operation
The Heated Zone Merchandiser is designed for efficient and
environmentally-friendly operation by heating specific “zones”
only when product is present. The operation of the Heated Zone
Merchandiser is controlled by a series of optical sensors and
the LCD controller. The sensors are located along the sides
of each hardcoat shelf. Larger units have additional sensors
located in zone dividers that separate each shelf into multiple
overhead heat zones.
For all sizes of units, each hardcoat shelf is equipped with
separate front and rear heating elements. These two elements
operate independently during Sensors ON operation.
The number of overhead ribbon heating elements is determined
by the size of the unit. The overhead elements above each
hardcoat shelf are considered individual heat zones. This
means that the number of zones on each shelf is either two,
four, or six—depending on the size of the unit. Each overhead
element operates independently during Sensors ON operation.
NOTE: Each shelf on a dual shelf Heated Zone Merchandiser
can be set to a different operating mode.
Sensors ON Operation
At startup in Sensors ON operation, all shelf heating elements
and overhead heating elements in an empty Heated Zone
Merchandiser will be in Stand-By. The front and rear shelf
elements will heat at their Stand-By power percentage to the
setpoint temperature. All overhead elements remain off. When
product is placed on a shelf, the optical sensors signal the LCD
controller, and the controller activates the appropriate shelf
elements and overhead elements. Each of the shelf elements
affected by the placement of product will heat at full wattage
to the setpoint temperature. Each of the overhead elements
affected by the placement of product will heat at its setpoint
power percentage. All affected elements will remain activated
until all product is removed from the “zone.” Anytime a zone is
emptied of product, the zone will return to Stand-By.
Sensors OFF Operation
At startup in Sensors OFF operation, all shelf heating elements
will heat at full wattage to the setpoint temperature, and all
overhead heating elements will heat at their setpoint power
percentage. All shelf elements will remain at full wattage and
all overhead elements will remain at their setpoint power
percentage the entire time the unit is on.
Lights Only Operation
At startup in Lights Only operation, all shelf heating elements
and overhead heating elements are disabled. Only the LED
lights above each shelf will illuminate. This mode provides
ambient lighting for the display of non-heated product.
Startup
1. Move the Power I/O (on/off) switch to the I (on) position.
The LED lights will illuminate.
The LCD controller will startup. After the startup screens
and during operation, the display will cycle through the
overhead heat zones showing their current status and
temperature.
Sensors ON = All shelf elements will heat at Stand-By
power percentage to the setpoint temperature. All
overhead elements remain off.
Sensors OFF = All shelf elements will heat at full wattage
to the setpoint temperature. All overhead elements will
heat at their setpoint power percentage.
Lights Only = All heating elements are disabled—for
ambient lighting only.
Display
Power I/O (on/off) Switch
Warning
Light
LCD Controller
HZM Series Control Panel
NOTE: If the warning light comes on at any time, the unit is
overheating/malfunctioning. Turn off and unplug the
unit. Contact an Authorized Service Agent or Hatco for
assistance.
CAUTION
BURN HAZARD: Some exterior surfaces on unit will get
hot. Use caution when touching these areas.
2. When unit is at operating temperature, place pre-heated,
wrapped food product onto the desired shelf.
Sensors ON = The optical sensors will signal the LCD
controller, and the controller will activate the appropriate
zone(s).
3. Continue to load and empty the shelves on the unit as
desired.
Sensors ON = The various zones in the unit will adjust
automatically to the levels of product on the shelves—
ensuring maximum efficiency.
NOTE:Tochangetheshelfsetpointtemperature(s),operating
mode, or the element power percentages, refer to the
appropriate procedure in this section.
Shutdown
1. Move the Power I/O (on/off) switch to the O (off) position.
All LED lights, heating elements, and the LCD controller
will shut off.
Form No. HZMM-1116
12
English
OPERATION
IMPORTANT NOTES:
Each of the following programming functions is separated
into specific procedures for each model.
Detailed flow charts showing the screen layout of the LCD
controller for both slanted and horizontal models are available
in this section of this manual.
Display
(Main Screen
shown)
Up Arrow
Key
Down Arrow
Key
Enter
Key
Close-Up View of LCD Controller
NOTE: Inactivity for five seconds at any level of programming
will cause the LCD controller to save the current
parameters and return to the Main screen.
Changing Shelf Setpoint Temperature and
Operating Mode
Use one of the following procedures to change the setpoint
temperature for the hardcoat shelf heating elements (front and
rear) as well as the operating mode for each shelf.
If necessary, refer to “Theory of Operations” at the beginning
of the OPERATION section for a description of each operating
mode.
NOTE: Press and hold the key for three seconds at any
time during programming to save settings and return to
the Main screen.
Horizontal and Slanted Single Shelf Models
1. From the Main screen, press the + keys. The
Lower Shelf Setpoint screen will appear:
lehSrwLf
• Press the key to increase setpoint value.
• Press the key to decrease setpoint value.
2. Press the key. The Lower Shelf Zones screen will
appear and show the active operating mode:
lehSrwLf
onesZ
ON
nesosrS
• Press the or key to toggle between operating
modes. There are three available operating modes:
Li ylOnsthg
lehSrwLf
onesZ
lehSf
onesZ
lehSf
onesZ
rwL
rwL
ON
nesosrS
OFF
nesosrS
Sensor-activated,
zone-specific
operation.
All elements on full-time.
Lights only. No heat.
3. Wait five seconds, or press and hold the key for three
seconds to save the desired setting and return to the Main
screen.
• The Parameters Saved screen will appear to confirm the
changes, and the display will return to the Main screen:
Pa sretemar
Sa dev
Horizontal and Slanted Dual Shelf Models
1. From the Main screen, press the + keys. The
Lower Shelf Setpoint screen will appear:
lehSrwLf
• Press the key to increase setpoint value.
• Press the key to decrease setpoint value.
2. Press the key. The Lower Shelf Zones screen will
appear and show the active operating mode:
lehSrwLf
onesZ
ON
nesosrS
• Press the or key to toggle between operating
modes. There are three available operating modes:
Li ylOnsthg
lehSrwLf
onesZ
lehSf
onesZ
lehSf
onesZ
rwL
rwL
ON
nesosrS
OFF
nesosrS
Sensor-activated,
zone-specific
operation.
All elements on full-time.
Lights only. No heat.
3. Press the key. The Upper Shelf Setpoint screen will
appear:
lehSf
Up rp
• Press the key to increase setpoint value.
• Press the key to decrease setpoint value.
4. Press the key. The Upper Shelf Zones screen will
appear and show the active operating mode:
lehSf
onesZ
ON
Up rp
nesosrS
• Press the or key to toggle between operating
modes. There are three available operating modes:
Li ylOnsthg
lehSf
onesZ
lehSf
onesZ
lehSf
onesZ
ON
Up rp
nesosrS
nesosrS
OFF
Up rp
Up rp
Sensor-activated,
zone-specific
operation.
All elements on full-time.
Lights only. No heat.
Form No. HZMM-1116
13
English
OPERATION
5. Wait five seconds, or press and hold the key for three
seconds to save the desired setting and return to the Main
screen.
• The Parameters Saved screen will appear to confirm the
changes, and the display will return to the Main screen:
Pa sretemar
Sa dev
Changing Element Power Percentages
Use one of the following procedures to change power
percentages for the overhead ribbon heating elements.
NOTE: Inactivity for five seconds at any level of programming
will cause the LCD controller to save the current
parameters and return to the Main screen.
Horizontal Single Shelf Models
1. From the Main screen, press and hold the +
keys for three seconds. The Temperature Mode screen will
appear and show the unit of measure that is active:
Te rutar
eeed
oMpm
Fa erhehnti
2. Press the key. The Lower Shelf Top screen will
appear and show the power percentage for the lower shelf
overhead heating elements:
Lo
pTflheSrw
%57
• Press the key to increase value by 5%.
• Press the key to decrease value by 5%.
3. Wait five seconds, or press and hold the key for three
seconds to save the desired setting and return to the Main
screen.
• The Parameters Saved screen will appear to confirm the
changes, and the display will return to the Main screen:
Pa sretemar
Sa dev
Slanted Single Shelf Models
1. From the Main screen, press and hold the +
keys for three seconds. The Temperature Mode screen will
appear and show the unit of measure that is active:
Te rutar
eeed
oMpm
Fa erhehnti
2. Press the key. The Lower Shelf Top screen will appear
and show the power percentage for the front and rear
lower shelf overhead heating elements:
Lo
pTflheSrw
Fr raeR%57
t0
5%
The value for the front lower shelf overhead heating
elements is active.
• Press the key to increase value by 5%.
• Press the key to decrease value by 5%.
3. Press the key.
The value for the rear lower shelf overhead heating
elements is now active.
• Press the key to increase value by 5%.
• Press the key to decrease value by 5%.
4. Wait five seconds, or press and hold the key for three
seconds to save the desired setting and return to the Main
screen.
• The Parameters Saved screen will appear to confirm the
changes, and the display will return to the Main screen:
Pa sretemar
Sa dev
Horizontal Dual Shelf Models
1. From the Main screen, press and hold the +
keys for three seconds. The Temperature Mode screen
will appear and show the unit of measure that is active:
Te rutar
eeed
oMpm
Fa erhehnti
2. Press the key. The Lower Shelf Top screen will
appear and show the power percentage for the lower shelf
overhead heating elements:
Lo
pTflheSrw
%57
• Press the key to increase value by 5%.
• Press the key to decrease value by 5%.
3. Press the key. The Upper Shelf Top screen will
appear and show the power percentage for the upper shelf
overhead heating elements:
opTflheS
rUpp
%57
• Press the key to increase value by 5%.
• Press the key to decrease value by 5%.
4. Wait five seconds, or press and hold the key for three
seconds to save the desired setting and return to the Main
screen.
• The Parameters Saved screen will appear to confirm the
changes, and the display will return to the Main screen:
Pa sretemar
Sa dev
Form No. HZMM-1116
14
English
OPERATION
Display
(Main Screen
shown)
Up Arrow
Key
Down Arrow
Key
Enter
Key
Close-Up View of LCD Controller
Slanted Dual Shelf Models
1. From the Main screen, press and hold the +
keys for three seconds. The Temperature Mode screen
will appear and show the unit of measure that is active:
Te rutar
eeed
oMpm
Fa erhehnti
NOTE: Inactivity for five seconds at any level of programming
will cause the LCD controller to save the current
parameters and return to the Main screen.
2. Press the key. The Lower Shelf Top screen will
appear and show the power percentage for the front and
rear lower shelf overhead heating elements:
Lo
pTflheSrw
Fr raeR%57
t0
5%
The value for the front lower shelf overhead heating
elements is active.
• Press the key to increase value by 5%.
• Press the key to decrease value by 5%.
3. Press the key.
The value for the rear lower shelf overhead heating
elements is now active.
• Press the key to increase value by 5%.
• Press the key to decrease value by 5%.
4. Press the key. The Upper Shelf Top screen will
appear and show the power percentage for the front and
rear upper shelf overhead heating elements:
opTflheS
rUpp
Fr raeR%57
t5
0%
The value for the front upper shelf overhead heating
elements is active.
• Press the key to increase value by 5%.
• Press the key to decrease value by 5%.
5. Press the key.
The value for the rear upper shelf overhead heating
elements is now active.
• Press the key to increase value by 5%.
• Press the key to decrease value by 5%.
6. Wait five seconds, or press and hold the key for three
seconds to save the desired setting and return to the Main
screen.
• The Parameters Saved screen will appear to confirm the
changes, and the display will return to the Main screen:
Pa sretemar
Sa dev
Changing Between Fahrenheit and Celsius
Use the following procedure to change/toggle the unit of
measure between fahrenheit and celsius for the temperature
shown on the display.
1. From the Main screen, press and hold the +
keys for three seconds. The Temperature Mode screen
will appear and show the unit of measure that is active:
Te rutar
eeed
oMpm
Fa erhehnti
2. Press the or key to toggle between units of
measure.
Te rutar
eeed
oMpm
Ce iclsu
3. Wait five seconds, or press and hold the key for three
seconds to save the desired setting and return to the Main
screen.
Form No. HZMM-1116
15
English
OPERATION
Li ylOnsthg
Li ylOnsthg
Te rutareeedoMpm
Fa erhehnti
Te rutareeedoMpm
Ce islsu
Ca bil
H3=siseretsyF
O0=tesffF
M 200=PSxaF
H3=siseretsyF
O0=tesffF
200=PSF
Mxa
Press and hold
for 3 seconds
Press
to increase
value
Press and hold
+
for 3 seconds
Main Screen
Service Menu
(Hatco only)
Settings Menu
(Management only)
Press
Press
Press
Press
Press
to increase
value
Press
to decrease
value
Press
to decrease
value
Press and hold
Press and hold
or wait 5 seconds
(this can be done from
any of the above screens)
Press and hold
or wait 5 seconds
(this can be done from
any of the above screens)
or wait 5 seconds
(this can be done from
any of the above screens)
LCD Controller Flow Chart — Horizontol Shelf Models
+
+
Pa sretemar
Sa dev
User Menus
Pa sretemar
Sa dev
Press
Press
Press
to increase or
decrease value
by 5%
or
Press
to increase or
decrease value
by 5%
or
Press
to increase or
decrease value
or
Press
to increase or
decrease value
by 5%
or
Press
to toggle
between
or
Press
to toggle
through
settings
or
Press
to increase or
decrease value
by 5%
or
Press
Press
Press
Press
Press
Press
Press
to toggle
through
settings
to toggle
through
settings
or
Press
Press
Press
Press
Stand-By Mode
Ca rwLbil
Ca rwLbil
Ca pUprbil
Ca pUprbil
Ca pUprbil
rwL
lehSrwLf
lehSrwLf
onesZ
lehSf
onesZ
lehSf
lehSf
onesZ
lehSf
onesZ
lehSf
onesZ
lehSf
onesZ
rwL
rwL
ON
Up rp
Up rp
nesosrS
nesosrS
OFF
Up rp
Up rp
LrwBeasflehS
flehS
flehS
flehS
flehS
flehS
flehS
flehS
%05
Up rpBase
%05
LopTflheS
opTflheS
rw
%57
rUpp
%57
ON
nesosrS
OFF
nesosrS
Form No. HZMM-1116
16
English
OPERATION
Li ylOnsthg
Li ylOnsthg
Te rutareeedoMpm
Fa erhehnti
Te rutareeedoMpm
Ce islsu
Ca bil
H3=siseretsyF
O0=tesffF
M 200=PSxaF
H3=siseretsyF
O0=tesffF
200=PSF
Mxa
Press and hold
for 3 seconds
Press
to increase
value
Press and hold
+
for 3 seconds
Main Screen
Service Menu
(Hatco only)
Settings Menu
(Management only)
Press
Press
Press
Press
Press
Press
to increase
value
Press
to decrease
value
Press
to decrease
value
Press and hold
Press and hold
or wait 5 seconds
(this can be done from
any of the above screens)
Press and hold
or wait 5 seconds
(this can be done from
any of the above screens)
or wait 5 seconds
(this can be done from
any of the above screens)
LCD Controller Flow Chart — Slanted Shelf Models
+
+
Press
Press
Pa sretemar
Sa dev
User Menus
Pa sretemar
Sa dev
Press
Press
Press
Press
Press
Press
Press
Press
to increase or
decrease value
by 5%
or
Press
to increase or
decrease value
by 5%
or
Press
to increase or
decrease value
or
Press
to increase or
decrease value
by 5%
or
Press
to toggle
between
or
Press
to toggle
through
settings
or
Press
to increase or
decrease value
by 5%
or
Press
Press
Press
Press
Press
Press
Press
to toggle
through
settings
or
Stand-By Mode
Ca rwLbil
Ca rwLbil
Ca pUprbil
Ca pUprbil
Ca pUprbil
rwL
lehSrwLf
lehSrwLf
onesZ
lehSf
onesZ
lehSf
lehSf
onesZ
lehSf
onesZ
lehSf
onesZ
lehSf
onesZ
rwL
rwL
ON
Up rp
Up rp
nesosrS
nesosrS
OFF
Up rp
Up rp
LrwBeasflehS
flehS
flehS
flehS
flehS
flehS
flehS
flehS
Fr raeR%05t0%
Up rpBase
Fr raeR%05t0%
LopTflheS
opTflheS
rw
Fr raeR%57t05%
rUpp
Fr raeR%57t50%
ON
nesosrS
OFF
nesosrS
Form No. HZMM-1116
17
English
MAINTENANCE
General
Hatco Heated Zone Merchandisers are designed for maximum
durability and performance with minimum maintenance.
WARNING
ELECTRIC SHOCK HAZARD:
• Turn OFF power switch, unplug power cord, and allow
unit to cool before performing any cleaning, setup, or
maintenance.
DO NOT submerge or saturate with water. Unit is not
waterproof. Do not operate if unit has been submerged
or saturated with water.
• Do not steam clean or use excessive water on unit.
This unit is not “jet-proof” construction. Do not use
jet-clean spray to clean this unit.
• Do not clean unit when it is energized or hot.
Use only Genuine Hatco Replacement Parts when
service is required. Failure to use Genuine Hatco
Replacement Parts will void all warranties and may
subject operators of the equipment to hazardous
electrical voltage, resulting in electrical shock or burn.
Genuine Hatco Replacement Parts are specified to
operate safely in the environments in which they are
used. Some aftermarket or generic replacement parts
do not have the characteristics that will allow them to
operate safely in Hatco equipment.
This unit has no “user-serviceable” parts. If service
is required on this unit, contact an Authorized Hatco
Service Agent or contact the Hatco Service Department at
800-558-0607 or 414-671-6350.
CAUTION
Do not move or relocate unit for cleaning. Unit is bulky
and heavy.
Daily Cleaning
To maintain performance and preserve the finish of the Heated
Zone Merchandiser, clean the unit daily.
NOTICE
Clean unit daily to avoid malfunctions and maintain
sanitary operation.
Use non-abrasive cleaners and cloths only. Abrasive
cleaners and cloths could scratch finish of unit, marring its
appearance and making it susceptible to soil accumulation.
IMPORTANT—DO NOT use paper towel or glass cleaner
to clean plastic surfaces such as sneeze guards and
flip-up doors. Paper towel and glass cleaner may scratch
the material. Wipe off plastic surfaces using a soft, clean,
water-dampened cloth.
1. Turn off the unit, unplug the power cord, and allow the unit
to cool.
2. Remove and discard any remaining food product.
3. Swing open the glass side panels for easy access to the
entire shelf for cleaning.
NOTE: The glass side panels are held closed magnetically.
4. Remove and clean the product divider rods and channel
dividers.
Lift the product divider rods straight up and out of the
channel dividers.
The channel dividers are held in place by magnets
positioned along the front edge and back edge of the
shelf. To remove a channel divider, pull the divider away
from the edge.
Channel Divider
Product
Divider Rod
Glass Side Panel
swung open.
Make sure sensor
is not blocked.
Optical Sensors
Cleaning a Heated Zone Merchandiser
5. Make sure the optical sensors on each side of the heated
shelves and in the zone dividers are not blocked by debris.
If they are blocked, carefully use a soft cloth or toothpick
to remove the debris.
6. Wipe down all exterior and interior surfaces using a non-
abrasive, damp cloth (a non-abrasive cleaner may be
used for difficult stains).
7. Wipe dry all surfaces using a non-abrasive, dry cloth.
8. Clean the glass side panels using a standard glass
cleaner.
9. If equipped, clean the plastic sneeze guards or flip-up
doors using soft cleaning cloths, mild soap, and water.
NOTICE: Do not use paper towel or glass cleaner on
plastic surfaces—scratching may occur.
Form No. HZMM-1116
18
English
Symptom Probable Cause Corrective Action
Display lights not working. Power turned off. Move Power I/O switch to the I (on) position.
LED display lights or driver defective. Contact Authorized Service Agent or Hatco for assistance.
Unit not hot enough. Unit in Stand-By (not loaded with food product). Load food product. Optical sensors will signal LCD controller
to energize unit and heat to setpoint temperatures/power
percentages.
Unit/shelf in Lights Only operation. Change unit/shelf operation to Sensors On or Sensors Off.
Refer to the OPERATION section for procedure.
Temperature setpoints/power percentages set
too low.
Adjust temperature setpoints/power percentages to higher
settings. Refer to the OPERATION section for procedures.
Heating element(s) not working. Contact Authorized Service Agent or Hatco for assistance.
Sensors or LCD controller not working properly. Contact Authorized Service Agent or Hatco for assistance.
Excessive air movement around unit. Restrict or redirect air movement (i.e., air conditioning duct
or exhaust fan) away from unit or install flip-up doors on unit
to block air flow.
Unit connected to incorrect power supply. Contact Authorized Service Agent or Hatco for assistance.
Unit too hot. Temperature setpoints/power percentages set
too high.
Adjust temperature setpoints/power percentages to lower
settings. Refer to the OPERATION section for procedures.
Sensors or LCD controller not working properly. Contact Authorized Service Agent or Hatco for assistance.
Sensor(s) may be blocked. Remove any objects that are blocking sensor(s).
Unit connected to incorrect power supply. Contact Authorized Service Agent or Hatco for assistance.
No heat, but light works. Unit/shelf in Lights Only operation. Change unit/shelf operation to Sensors On or Sensors Off.
Refer to the OPERATION section for procedure.
Temperature setpoints/power percentages set
too low.
Adjust temperature setpoints/power percentages to higher
settings. Refer to the OPERATION section for procedures.
Heating element(s) not working. Contact Authorized Service Agent or Hatco for assistance.
Heating element(s) not working. Contact Authorized Service Agent or Hatco for assistance.
No heat and no light. Heating element(s) not working. Move Power I/O switch to the I (on) position.
Circuit breaker tripped. Reset circuit breaker. If circuit breaker continues to trip,
contact Authorized Service Agent or Hatco for assistance.
TROUBLESHOOTING GUIDE
WARNING
This unit must be serviced by qualified personnel only.
Service by unqualified personnel may lead to electric
shock or burn.
WARNING
ELECTRIC SHOCK HAZARD: Turn OFF power switch,
unplug power cord, and allow unit to cool before
performing any cleaning, setup, or maintenance.
Troubleshooting Questions?
If you continue to have problems resolving an issue, please contact the nearest Authorized Hatco Service Agency or Hatco
for assistance. To locate the nearest Service Agency, log onto the Hatco website at www.hatcocorp.com and click on
Find Service Agent, or contact the Hatco Parts and Service Team at:
Telephone: 800-558-0607 or 414-671-6350
Form No. HZMM-1116
19
English
OPTIONS AND ACCESSORIES
Flip-Up Doors
Flip-up doors are available for all models as an added option at
the time of order. Flip-up doors can be installed on each shelf
on either the customer side or operator side of the unit. Use the
following procedure to install flip-up doors (the procedure is the
same for either side as well as each shelf).
1. Align the screw holes at each end of the flip-up door hinge
with the mounting hole in each end plate on the unit.
2. Insert a hinge screw through each end plate and into the
flip-up door.
3. Tighten the hinge screws until the flip-up door is secure.
Do not over-tighten the screws.
Flip-Up Door
Hinge Screw
Mounting
Hole
Hinge
Flip-Up Door Installation
Sneeze Guards
Sneeze guards are available for all models as an added option
at the time of order. Sneeze guards can be installed above
each shelf on the customer side of the unit.
Support Post Accent Lighting
Support post accent lighting is available for all models as an
added option at the time of order. The accent lighting consists
of a vertical strip of LED lights running up the center of each
support post.
Product Divider Rods
Stainless steel product divider rods are available as an
accessory.
HZM-DIV Stainless Steel Divider Rod
Element Guard
Element guards are available for all models as an added option
at the time of order. Element guards can be installed on each
overhead element for further protection against incidental
touches.
Form No. HZMM-1116
20
English
LIMITED WARRANTY
1. PRODUCT WARRANTY
Hatco warrants the products that it manufactures (the
“Products”) to be free from defects in materials and
workmanship, under normal use and service, for a period of
one (1) year from the date of purchase when installed and
maintained in accordance with Hatco’s written instructions
or 18 months from the date of shipment from Hatco. Buyer
must establish the Product’s purchase date by registering the
Product with Hatco or by other means satisfactory to Hatco in
its sole discretion.
Hatco warrants the following Product components to be free
from defects in materials and workmanship from the date of
purchase (subject to the foregoing conditions) for the period(s)
of time and on the conditions listed below:
a) One (1) Year Parts and Labor PLUS One (1) Additional
Year Parts-Only Warranty:
Conveyor Toaster Elements (metal sheathed)
Drawer Warmer Elements (metal sheathed)
Drawer Warmer Drawer Rollers and Slides
Strip Heater Elements (metal sheathed)
Display Warmer Elements (metal sheathed air heating)
Holding Cabinet Elements (metal sheathed air heating)
Heated Well Elements—HW and HWB Series
(metal sheathed)
b) Two (2) Year Parts and Labor Warranty:
Induction Ranges
c) One (1) Year Parts and Labor PLUS Four (4) Years
Parts-Only Warranty:
3CS and FR Tanks
d) One (1) Year Parts and Labor PLUS Nine (9) Years
Parts-Only Warranty on:
Electric Booster Heater Tanks
Gas Booster Heater Tanks
e) Ninety (90) Day Parts-Only Warranty:
Replacement Parts
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND
IN LIEU OF ANY OTHER WARRANTY, EXPRESSED OR
IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE OR PATENT OR OTHER
INTELLECTUAL PROPERTY RIGHT INFRINGEMENT. Without
limiting the generality of the foregoing, SUCH WARRANTIES
DO NOT COVER: Coated incandescent light bulbs, fluorescent
lights, heat lamp bulbs, coated halogen light bulbs, halogen
heat lamp bulbs, xenon light bulbs, LED light tubes, glass
components, and fuses; Product failure in booster tank, fin
tube heat exchanger, or other water heating equipment caused
by liming, sediment buildup, chemical attack, or freezing;
or Product misuse, tampering or misapplication, improper
installation, or application of improper voltage.
2. LIMITATION OF REMEDIES AND DAMAGES
Hatco’s liability and Buyer’s exclusive remedy hereunder will
be limited solely, at Hatco’s option, to repair or replacement
using new or refurbished parts or Product by Hatco or a Hatco-
authorized service agency (other than where Buyer is located
outside of the United States, Canada, United Kingdom, or
Australia, in which case Hatco’s liability and Buyer’s exclusive
remedy hereunder will be limited solely to replacement of part
under warranty) with respect to any claim made within the
applicable warranty period referred to above. Hatco reserves
the right to accept or reject any such claim in whole or in part. In
the context of this Limited Warranty, “refurbished” means a part
or Product that has been returned to its original specifications
by Hatco or a Hatco-authorized service agency. Hatco will not
accept the return of any Product without prior written approval
from Hatco, and all such approved returns shall be made
at Buyer’s sole expense. HATCO WILL NOT BE LIABLE,
UNDER ANY CIRCUMSTANCES, FOR CONSEQUENTIAL
OR INCIDENTAL DAMAGES, INCLUDING BUT NOT LIMITED
TO LABOR COSTS OR LOST PROFITS RESULTING FROM
THE USE OF OR INABILITY TO USE THE PRODUCTS OR
FROM THE PRODUCTS BEING INCORPORATED IN OR
BECOMING A COMPONENT OF ANY OTHER PRODUCT OR
GOODS.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Hatco HZMH, HZMH-xxD, HZMS, HZMS-xxD Series Le manuel du propriétaire

Taper
Le manuel du propriétaire