Behringer CT200 Guide de démarrage rapide

Taper
Guide de démarrage rapide
Quick Start Guide
CT200
Microprocessor-Controlled 8-in-1 Cable Tester
2 CT200 3Quick Start Guide
9. Do not defeat the safety purpose of
the polarized or grounding-type plug.
A polarized plug has two blades with one
wider than the other. A grounding-type
plug has two blades and a third grounding
prong. The wide blade or the third
prong are provided for your safety. Ifthe
provided plug does not  t into your outlet,
consult an electrician for replacement of
the obsolete outlet.
10. Protect the power cord from being
walked on or pinched particularly at plugs,
convenience receptacles, and the point
where they exit from the apparatus.
11. Use only attachments/accessories
speci ed by themanufacturer.
12. Use only with
the cart, stand,
tripod, bracket,
or table speci ed by
the manufacturer,
orsold with
the apparatus. When a cart is used,
use caution when moving the cart/
apparatus combination to avoid injury
from tip-over.
13. Unplug this apparatus during
lightning storms or when unused for long
periods of time.
14. Refer all servicing to quali ed service
personnel. Servicing is required when
the apparatus has been damaged in any
way, such as power supply cord or plug
is damaged, liquid has been spilled or
objects have fallen into the apparatus,
the apparatus has been exposed to rain or
moisture, does not operate normally, or has
beendropped.
15. The apparatus
shall be connected to
a MAINS socket outlet
with a protective
earthing connection.
16. Where the MAINS plug or an
appliance coupler is used as the
disconnect device, the disconnect device
shall remain readily operable.
Terminals marked with this
symbol carry electrical current
of su cient magnitude to
constitute risk of electric
shock. Use only high-quality professional
speaker cables with ¼" TS or twist-locking
plugs pre-installed. Allother installation or
modi cation should be performed only
by quali edpersonnel.
This symbol, wherever it
appears, alertsyou to the
presence of uninsulated
dangerous voltage inside the
enclosure-voltage that may be su cient
to constitute a risk ofshock.
This symbol, wherever it
appears, alertsyou to
important operating and
maintenance instructions in the
accompanying literature. Please read
the manual.
Caution
To reduce the risk of electric
shock, donot remove the top
cover (or the rear section).
No user serviceable parts inside. Refer
servicing to quali ed personnel.
Caution
To reduce the risk of  re
or electric shock, do not
expose this appliance to
rain and moisture. The apparatus shall
not be exposed to dripping or splashing
liquids and no objects  lled with
liquids, suchas vases, shall be placed on
the apparatus.
Caution
These service instructions are
for use by quali ed service
personnel only. Toreduce the
risk of electric shock do not perform any
servicing other than that contained in the
operation instructions. Repairs have to be
performed by quali ed servicepersonnel.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation
openings. Install in accordance with the
manufacturer’s instructions.
8. Do not install near any heat sources
such as radiators, heat registers, stoves,
or other apparatus (including ampli ers)
that produce heat.
Important Safety
Instructions
4 CT200 5Quick Start Guide
17. Correct disposal of
this product: This symbol
indicates that this
product must not be
disposed of with
household waste, according to the WEEE
Directive (2012/19/EU) and your
national law. This product should be taken
to a collection center licensed for the
recycling of waste electrical and electronic
equipment (EEE). The mishandling of this
type of waste could have a possible
negative impact on the environment and
human health due to potentially hazardous
substances that are generally associated
with EEE. At the same time, your
cooperation in the correct disposal of this
product will contribute to the e cient use
of natural resources. For more information
about where you can take your waste
equipment for recycling, please contact
your local city o ce, or your household
waste collection service.
MUSIC Group accepts no liability for any
loss which may be su ered by any person
who relies either wholly or in part upon
any description, photograph, or statement
contained herein. Technical speci cations,
appearances and other information
are subject to change without notice.
All trademarks are the property of their
respective owners. Midas, Klark Teknik,
Lab Gruppen, Lake, Tannoy, Turbosound,
TC Electronic, TC Helicon, Behringer, Bugera,
DDA and TC Applied Technologies are
trademarks or registered trademarks of
MUSIC Group IP Ltd. © MUSIC Group IP Ltd.
2015 All rights reserved.
For the applicable warranty terms and
conditions and additional information
regarding MUSIC Group’s Limited Warranty,
please see complete details online at
music-group.com/warranty.
LEGAL DISCLAIMER LIMITED WARRANTY
Las terminales marcadas con
este símbolo transportan
corriente eléctrica de
magnitud su ciente como para constituir
un riesgo de descarga eléctrica. Utilice solo
cables de altavoz profesionales y de alta
calidad con conectores TS de 6,3 mm o de
bayoneta pre jados. Cualquier otra
instalación o modi cación debe ser
realizada únicamente por un
técnico cuali cado.
Este símbolo, siempre que
aparece, leadvierte de la
presencia de voltaje peligroso
sin aislar dentro de la caja; estevoltaje
puede ser su ciente para constituir un
ries
g
o dedescar
g
a.
Este símbolo, siempre que
aparece, leadvierte sobre
instrucciones operativas y de
mantenimiento que aparecen en la
documentación adjunta. Por favor,
lea el manual.
Atención
Para reducir el riesgo
de descarga eléctrica,
no quite la tapa (o la parte posterior).
No hay piezas en el interior del equipo
que puedan ser reparadas por el usuario.
Si es necesario, póngase en contacto con
personal cuali cado.
Atención
Para reducir el riesgo de
incendio o descarga eléctrica,
no exponga este aparato a la
lluvia, humedad o alguna otra fuente que
pueda salpicar o derramar algún líquido
sobre el aparato. Nocoloque ningún tipo
de recipiente para líquidos sobre el aparato.
Atención
Las instrucciones de
servicio deben llevarlas
a cabo exclusivamente personal
cuali cado. Para evitar el riesgo de una
descarga eléctrica, no realice reparaciones
que no se encuentren descritas en el
manual de operaciones. Lasreparaciones
deben ser realizadas exclusivamente por
personalcuali cado.
1. Lea las instrucciones.
2. Conserve estas instrucciones.
3. Preste atención a todas las advertencias.
4. Siga todas las instrucciones.
5. No use este aparato cerca del agua.
6. Limpie este aparato con un paño seco.
7. No bloquee las aberturas
de ventilación. Instale el equipo de acuerdo
con las instrucciones del fabricante.
Instrucciones de
seguridad
6 CT200 7Quick Start Guide
8. No instale este equipo cerca de
fuentes de calor tales como radiadores,
acumuladores de calor, estufas u otros
aparatos (incluyendo ampli cadores)
que puedan producir calor.
9. No elimine o deshabilite nunca la
conexión a tierra del aparato o del cable
de alimentación de corriente. Unenchufe
polarizado tiene dos polos, uno de los
cuales tiene un contacto más ancho que
el otro. Una clavija con puesta a tierra
dispone de tres contactos: dos polos y
la puesta a tierra. El contacto ancho y el
tercer contacto, respectivamente, son los
que garantizan una mayor seguridad.
Si el enchufe suministrado con el equipo
no concuerda con la toma de corriente,
consulte con un electricista para cambiar
la toma de corriente obsoleta.
10. Coloque el cable de suministro
de energía de manera que no pueda
ser pisado y que esté protegido de
objetos a lados. Asegúrese de que el cable
de suministro de energía esté protegido,
especialmente en la zona de la clavija y en
el punto donde sale del aparato.
11. Use únicamente los dispositivos o
accesorios especi cados por el fabricante.
12. Use
únicamente
la carretilla,
plataforma, trípode,
soporte o mesa
especi cados
por el fabricante o suministrados junto
con el equipo. Altransportar el equipo,
tenga cuidado para evitar daños y caídas al
tropezar con algún obstáculo.
13. Desenchufe el equipo durante
tormentas o si no va a utilizarlo durante un
periodo largo.
14. Confíe las reparaciones únicamente
a servicios técnicos cuali cados. La unidad
requiere mantenimiento siempre que
haya sufrido algún daño, si el cable
de suministro de energía o el enchufe
presentaran daños, sehubiera derramado
un líquido o hubieran caído objetos dentro
del equipo, si el aparato hubiera estado
expuesto a la humedad o la lluvia, si ha
dejado de funcionar de manera normal o si
ha sufrido algún golpe o caída.
15. Al conectar la unidad a la toma de
corriente eléctrica asegúrese de que la
conexión disponga de una unión atierra.
16. Si el enchufe o conector de red
sirve como único medio de desconexión,
éste debe ser accesiblefácilmente.
17. Cómo debe
deshacerse de este
aparato: Este símbolo
indica que este aparato
no debe ser tratado como
basura orgánica, según lo indicado en la
Directiva WEEE (2012/19/EU) y a las
normativas aplicables en su país. En lugar
de ello deberá llevarlo al punto limpio más
cercano para el reciclaje de sus elementos
eléctricos/ electrónicos (EEE). Al hacer esto
estará ayudando a prevenir las posibles
consecuencias negativas para el medio
ambiente y la salud que podrían ser
provocadas por una gestión inadecuada de
este tipo de aparatos. Además, el reciclaje
de materiales ayudará a conservar los
recursos naturales. Para más información
acerca del reciclaje de este aparato,
póngase en contacto con el Ayuntamiento
de su ciudad o con el punto limpio local.
MUSIC Group no admite ningún tipo
de responsabilidad por cualquier
daño o pérdida que pudiera sufrir
cualquier persona por con ar total
o parcialmente en la descripciones,
fotografías o a rmaciones contenidas
en este documento. Las especi caciones
técnicas, imágenes y otras informaciones
contenidas en este documento están
sujetas a modi caciones sin previo
aviso. Todas las marcas comerciales que
aparecen aquí son propiedad de sus
respectivos dueños. Midas, Klark Teknik,
Lab Gruppen, Lake, Tannoy, Turbosound,
TC Electronic, TC Helicon, Behringer, Bugera,
DDA y TC Applied Technologies son marcas
comerciales o marcas registradas de
MUSIC Group IP Ltd. © MUSIC Group IP Ltd.
2015 Reservados todos los derechos.
Si quiere conocer los detalles y condiciones
aplicables de la garantía así como
información adicional sobre la Garantía
limitada de MUSIC Group, consulte
online toda la información en la web
music-group.com/warranty.
GARANT
Í
ANEGACI
Ó
N LEGAL
8 CT200 9Quick Start Guide
Consignes de sécurité
Les points repérés par ce
symbole portent une tension
électrique su sante pour
constituer un risque d’électrocution.
Utilisez uniquement des câbles d’enceintes
professionnels de haute qualité avec  ches
Jack mono 6,35 mm ou  ches à
verrouillages déjà installées. Touteautre
installation ou modi cation doit être
e ectuée uniquement par un
personnel quali é.
Ce symbole avertit de la
présence d’une tension
dangereuse et non isolée à
l’intérieur de l’appareil - elle peut
provoquer des chocs électriques.
Attention
Ce symbol signale les
consignes d’utilisation
et d’entre ! Tien importantes dans la
documentation fournie. Lisez les consignes
de sécurité du manuel d’utilisation
de l’appareil.
Attention
Pour éviter tout risque de
choc électrique, ne pas
ouvrir le capot de l’appareil ni démonter
le panneau arrière. Lintérieur de l’appareil
ne possède aucun élément réparable par
l’utilisateur. Laissertoute réparation à un
professionnel quali é.
Attention
Pour réduire les risques de
feu et de choc électrique,
n’exposez pas cet appareil à la pluie,
à la moisissure, aux gouttes ou aux
éclaboussures. Ne posez pas de récipient
contenant un liquide sur l’appareil (un vase
par exemple).
Attention
Ces consignes de sécurité et
d’entretien sont destinées
à un personnel quali é. Pouréviter tout
risque de choc électrique, n’e ectuez
aucune réparation sur l’appareil qui ne
soit décrite par le manuel d’utilisation.
Les éventuelles réparations doivent
être e ectuées uniquement par un
technicien spécialisé.
1. Lisez ces consignes.
2. Conservez ces consignes.
3. Respectez tous les avertissements.
4. Respectez toutes les consignes
d’utilisation.
5. N’utilisez jamais l’appareil à proximité
d’un liquide.
6. Nettoyez l’appareil avec un chi on sec.
7. Veillez à ne pas empêcher la bonne
ventilation de l’appareil via ses ouïes
de ventilation. Respectezles consignes
du fabricant concernant l’installation
del’appareil.
8. Ne placez pas l’appareil à proximité
d’une source de chaleur telle qu’un
chau age, une cuisinière ou tout appareil
dégageant de la chaleur (y compris un
ampli depuissance).
9. Ne supprimez jamais la sécurité des
prises bipolaires ou des prises terre.
Les prises bipolaires possèdent deux
contacts de largeur di érente. Leplus
large est le contact de sécurité. Les prises
terre possèdent deux contacts plus une
mise à la terre servant de sécurité. Si la
prise du bloc d’alimentation ou du cordon
d’ali-mentation fourni ne correspond pas à
celles de votre installation électrique, faites
appel à un électricien pour e ectuer le
changement de prise.
10. Installez le cordon d’alimentation
de telle façon que personne ne puisse
marcher dessus et quil soit protégé
d’arêtes coupantes. Assurez-vous que le
cordon d’alimentation est sufsamment
protégé, notamment au niveau de sa prise
électrique et de l’endroit où il est relié à
l’appareil; cela est également valable pour
une éventuelle rallonge électrique.
11. Utilisez exclusivement des accessoires
et des appareils supplémentaires
recommandés par lefabricant.
12. Utilisez
exclusivement des
chariots, des diables,
desprésentoirs,
despieds et
des surfaces
de travail recommandés par le
fabricant ou livrés avec le produit.
Déplacezprécautionneusement tout
chariot ou diable chargé pour éviter
d’éventuelles blessures en cas dechute.
13. Débranchez l’appareil de la tension
secteur en cas d’orage ou si l’appareil reste
inutilisé pendant une longue période
de temps.
14. Les travaux d’entretien de l’appareil
doivent être e ectués uniquement par
du personnel qualié. Aucunentretien
n’est nécessaire sauf si l’appareil est
endommagé de quelque façon que ce soit
(dommagessur le cordon d’alimentation
ou la prise par exemple), siun liquide
ou un objet a pénétré à l’intérieur du
châssis, si l’appareil a été exposé à la pluie
ou à l’humidité, s’il ne fonctionne pas
correctement ou à la suite d’une chute.
15. L’appareil doit être connecté à une
prise secteur dotée d’une protection par
mise à la terre.
16. La prise électrique ou la prise IEC de
tout appareil dénué de bouton marche/
arrêt doit rester accessible enpermanence.
10 CT200 11Quick Start Guide
17. Mise au rebut
appropriée de ce produit:
Ce symbole indique quen
accord avec la directive
DEEE (2012/19/EU) et les
lois en vigueur dans votre pays, ce produit
ne doit pas être jeté avec les déchets
ménagers. Ce produit doit être déposé dans
un point de collecte agréé pour le recyclage
des déchets d’équipements électriques et
électroniques (EEE). Une mauvaise
manipulation de ce type de déchets
pourrait avoir un impact négatif sur
l’environnement et la santé à cause des
substances potentiellement dangereuses
généralement associées à ces équipements.
En même temps, votre coopération dans la
mise au rebut de ce produit contribuera à
l’utilisation e cace des ressources
naturelles. Pour plus d’informations sur
l’endroit où vous pouvez déposer vos
déchets d’équipements pour le recyclage,
veuillez contacter votre mairie ou votre
centre local de collecte des déchets.
MUSIC Group ne peut être tenu
pour responsable pour toute perte
pouvant être subie par toute personne
se  ant en partie ou en totalité à
toute description, photographie ou
a rmation contenue dans ce document.
Les caractéristiques, l’apparence et
d’autres informations peuvent faire
l’objet de modi cations sans noti cation.
Toutes les marques appartiennent à leurs
propriétaires respectifs. Midas, Klark Teknik,
Lab Gruppen, Lake, Tannoy, Turbosound,
TC Electronic, TC Helicon, Behringer,
Bugera, DDA et TC Applied Technologies
sont des marques ou marques déposées de
MUSIC Group IP Ltd. © MUSIC Group IP Ltd.
2015 Tous droits réservés.
Pour connaître les termes et conditions
de garantie applicables, ainsi que
les informations supplémentaires
et détaillées sur la Garantie Limitée
de MUSIC Group, consultez le site
Internet music-group.com/warranty.
D
É
NI L
É
GAL GARANTIE LIMIT
É
E
Wichtige
Sicherhteitshinweise
Vorsicht
Die mit dem Symbol
markierten Anschlüsse führen
so viel Spannung, dassdie Gefahr eines
Stromschlags besteht.
Verwenden Sie nur hochwertige,
professionelle Lautsprecherkabel
mit vorinstallierten 6,35 mm MONO-
Klinkensteckern oder Lautsprecherstecker
mit Drehverriegelung. Alle anderen
Installationen oder Modi kationen sollten
nur von quali ziertem Fachpersonal
ausgeführt werden.
Achtung
Um eine Gefährdung durch
Stromschlag auszuschließen,
darf die Geräteabdeckung bzw.
Geräterückwand nicht abgenommen
werden. ImInnern des Geräts be nden
sich keine vom Benutzer reparierbaren
Teile. Reparaturarbeiten dürfen
nur von quali ziertem Personal
ausgeführt werden.
Achtung
Um eine Gefährdung durch
Feuer bzw. Stromschlag
auszuschließen, darf dieses Gerät weder
Regen oder Feuchtigkeit ausgesetzt
werden noch sollten Spritzwasser oder
tropfende Flüssigkeiten in das Gerät
gelangen können. Stellen Sie keine mit
Flüssigkeit gefüllten Gegenstände, wie z. B.
Vasen, aufdasGerät.
Achtung
Die Service-Hinweise sind
nur durch quali ziertes
Personal zu befolgen. Umeine Gefährdung
durch Stromschlag zu vermeiden,
führen Sie bitte keinerlei Reparaturen
an dem Gerät durch, die nicht in der
Bedienungsanleitung beschrieben sind.
Reparaturen sind nur von quali ziertem
Fachpersonaldurchzuführen.
1. Lesen Sie diese Hinweise.
2. Bewahren Sie diese Hinweise auf.
3. Beachten Sie alle Warnhinweise.
4. Befolgen Sie alle Bedienungshinweise.
5. Betreiben Sie das Gerät nicht in der
Nähe vonWasser.
6. Reinigen Sie das Gerät mit einem
trockenen Tuch.
7. Blockieren Sie nicht die
Belüftungsschlitze. Beachten Sie beim
Einbau des Gerätes die Herstellerhinweise.
12 CT200 13Quick Start Guide
8. Stellen Sie das Gerät nicht in der
Nähe von Wärmequellen auf. Solche
Wärmequellen sind z. B. Heizkörper,
Herde oder andere Wärme erzeugende
Geräte (auch Verstärker).
9. Entfernen Sie in keinem Fall die
Sicherheitsvorrichtung von Zweipol- oder
geerdeten Steckern. Ein Zweipolstecker
hat zwei unterschiedlich breite
Steckkontakte. Ein geerdeter Stecker hat
zwei Steckkontakte und einen dritten
Erdungskontakt. Derbreitere Steckkontakt
oder der zusätzliche Erdungskontakt
dient Ihrer Sicherheit. Falls das
mitgelieferte Steckerformat nicht zu Ihrer
Steckdose passt, wenden Sie sich bitte
an einen Elektriker, damit die Steckdose
entsprechend ausgetauscht wird.
10. Verlegen Sie das Netzkabel so, dass es
vor Tritten und scharfen Kanten geschützt
ist und nicht beschädigt werden kann.
Achten Sie bitte insbesondere im Bereich
der Stecker, Verlängerungskabel und
an der Stelle, an der das Netzkabel das
Gerät verlässt, aufausreichendenSchutz.
11. Das Gerät muss jederzeit mit
intaktem Schutzleiter an das Stromnetz
angeschlossen sein.
12. Sollte der Hauptnetzstecker oder
eine Gerätesteckdose die Funktionseinheit
zum Abschalten sein, muss diese immer
zugänglich sein.
13. Verwenden Sie nur Zusatzgeräte/
Zubehörteile, dielaut Hersteller
geeignet sind.
14. Verwenden Sie
nur Wagen,
Standvorrichtungen,
Stative, Halter oder
Tische, die vom
Hersteller benannt
oder im Lieferumfang des Geräts enthalten
sind. Falls Sie einen Wagen benutzen, seien
Sie vorsichtig beim Bewegen der
Wagen- Gerätkombination, umVerletzungen
durch Stol
p
ern zuvermeiden.
15. Ziehen Sie den Netzstecker bei
Gewitter oder wenn Sie das Gerät längere
Zeit nicht benutzen.
16. Lassen Sie alle Wartungsarbeiten
nur von quali ziertem Service-Personal
ausführen. EineWartung ist notwendig,
wenn das Gerät in irgendeiner Weise
beschädigt wurde (z. B. Beschädigung des
Netzkabels oder Steckers), Gegenstände
oder Flüssigkeit in das Geräteinnere gelangt
sind, das Gerät Regen oder Feuchtigkeit
ausgesetzt wurde, das Gerät nicht
ordnungsgemäß funktioniert oder auf den
Boden gefallen ist.
17. Korrekte Entsorgung
dieses Produkts: Dieses
Symbol weist darauf hin,
das Produkt
entsprechend der WEEE
Direktive (2012/19/EU) und der jeweiligen
nationalen Gesetze nicht zusammen mit
Ihren Haushaltsabfällen zu entsorgen.
DiesesProdukt sollte bei einer autorisierten
Sammelstelle für Recycling elektrischer
und elektronischer Geräte (EEE) abgegeben
werden. Wegen bedenklicher Substanzen,
diegenerell mit elektrischen und
elektronischen Geräten in
Verbindung stehen, könnte eine
unsachgemäße Behandlung dieser
Abfallart eine negative Auswirkung auf
Umwelt und Gesundheit haben.
Gleichzeitig gewährleistet Ihr Beitrag zur
richtigen Entsorgung dieses Produkts die
e ektive Nutzung natürlicher Ressourcen.
Fürweitere Informationen zur Entsorgung
Ihrer Geräte bei einer Recycling-Stelle
nehmen Sie bitte Kontakt zum zuständigen
städtischen Büro, Entsorgungsamt oder zu
Ihrem Haushaltsabfallentsorgerauf.
MUSIC Group übernimmt keine Haftung
für Verluste, die Personen entstanden
sind, die sich ganz oder teilweise auf
hier enthaltene Beschreibungen,
Fotos oder Aussagen verlassen haben.
Technische Daten, Erscheinungsbild
und andere Informationen können
ohne vorherige Ankündigung
geändert werden. Alle Warenzeichen
sind Eigentum der jeweiligen Inhaber.
Midas, Klark Teknik, Lab Gruppen, Lake,
Tannoy, Turbosound, TC Electronic,
TC Helicon, Behringer, Bugera, DDA und
TC Applied Technologies sind Warenzeichen
oder eingetragene Warenzeichen der
MUSIC Group IP Ltd. © MUSIC Group IP Ltd.
2015 Alle Rechte vorbehalten.
Die geltenden Garantiebedingungen und
zusätzliche Informationen bezüglich der
von MUSIC Group gewährten beschränkten
Garantie  nden Sie online unter
music-group.com/warranty.
HAFTUNGSAUSSCHLUSS BESCHR
Ä
NKTE GARANTIE
14 CT200 15Quick Start Guide
Instruções de Segurança
Importantes
Aviso!
Terminais marcados com o
símbolo carregam corrente
elétrica de magnitude su ciente para
constituir um risco de choque elétrico.
Use apenas cabos de alto-falantes de
alta qualidade com plugues TS de ¼"
ou plugues com trava de torção pré-
instalados. Todas as outras instalações e
modi cações devem ser efetuadas por
pessoasquali cadas.
Este símbolo, onde quer que o
encontre, alerta-o para a
leitura das instruções de
manuseamento que acompanham
o equipamento. Por favor leia o
manual de instruções.
Atenção
De forma a diminuir o risco
de choque eléctrico, não
remover a cobertura (ouasecção de trás).
Não existem peças substituíveis por parte
do utilizador no seu interior. Para esse
efeito recorrer a um técnico quali cado.
Atenção
Para reduzir o risco de
incêndios ou choques
eléctricos o aparelho não deve ser exposto
à chuva nem à humidade. Além disso,
não deve ser sujeito a salpicos, nem
devem ser colocados em cima do
aparelho objectos contendo líquidos,
tais como jarras.
Atenção
Estas instruções de operação
devem ser utilizadas,
em exclusivo, por técnicos de assistência
quali cados. Para evitar choques eléctricos
não proceda a reparações ou intervenções,
que não as indicadas nas instruções de
operação, salvo se possuir as quali -cações
necessárias. Para evitar choques eléctricos
não proceda a reparações ou intervenções,
que não as indicadas nas instruções de
operação. Só o deverá fazer se possuir as
quali cações necessárias.
1. Leia estas instruções.
2. Guarde estas instruções.
3. Preste atenção a todos os avisos.
4. Siga todas as instruções.
5. Não utilize este dispositivo
perto de água.
6. Limpe apenas com um pano seco.
7. Não obstrua as entradas de ventilação.
Instale de acordo com as instruções
do fabricante.
8. Não instale perto de quaisquer fontes
de calor tais como radiadores, bocas
de ar quente, fogões de sala ou outros
aparelhos (incluindo ampli cadores)
que produzam calor.
9. Não anule o objectivo de segurança
das  chas polarizadas ou do tipo de ligação
à terra. Uma  cha polarizada dispõe de
duas palhetas sendo uma mais larga do
que a outra. Uma  cha do tipo ligação
à terra dispõe de duas palhetas e um
terceiro dente de ligação à terra. A palheta
larga ou o terceiro dente são fornecidos
para sua segurança. Se a  cha fornecida
não encaixar na sua tomada, consulte
um electricista para a substituição da
tomada obsoleta.
10. Proteja o cabo de alimentação de
pisadelas ou apertos, especialmente
nas  chas, extensões, e no local de
saída da unidade. Certi que-se de
que o cabo eléctrico está protegido.
Veri que particularmente nas  chas,
nos receptáculos e no ponto em que o cabo
sai doaparelho.
11. O aparelho tem de estar sempre
conectado à rede eléctrica com o condutor
de protecção intacto.
12. Se utilizar uma  cha de rede principal
ou uma tomada de aparelhos para desligar
a unidade de funcionamento, esta deve
estar sempre acessível.
13. Utilize apenas ligações/acessórios
especi cados pelofabricante.
14. Utilize apenas
com o carrinho,
estrutura, tripé,
suporte, ou mesa
especi cados
pelo fabricante ou
vendidos com o dispositivo. Quandoutilizar
um carrinho, tenha cuidado ao mover o
conjunto carrinho/dispositivo para evitar
danos provocados pela terpidação.
15. Desligue este dispositivo durante
as trovoadas ou quando não for utilizado
durante longos períodos detempo.
16. Qualquer tipo de reparação deve ser
sempre efectuado por pessoal quali cado.
É necessária uma reparação sempre que
a unidade tiver sido de alguma forma
dani cada, como por exemplo: no caso
do cabo de alimentação ou  cha se
encontrarem dani cados; naeventualidade
de líquido ter sido derramado ou objectos
terem caído para dentro do dispositivo;
no caso da unidade ter estado exposta
à chuva ou à humidade; seesta não
funcionar normalmente, ou se tiver caído.
17. Correcta eliminação
deste produto:
este símbolo indica
que o produto não
deve ser eliminado
juntamente com os resíduos domésticos,
segundo a Directiva REEE (2012/19/EU)
e a legislação nacional. Este produto
deverá ser levado para um centro de
recolha licenciado para a reciclagem de
resíduos de equipamentos eléctricos
16 CT200 17Quick Start Guide
e electrónicos (EEE). O tratamento
incorrecto deste tipo de resíduos pode
ter um eventual impacto negativo no
ambiente e na saúde humana devido a
substâncias potencialmente perigosas
que estão geralmente associadas aos
EEE. Ao mesmo tempo, a sua colaboração
para a eliminação correcta deste
produto irá contribuir para a utilização
e ciente dos recursos naturais. Paramais
informação acerca dos locais onde poderá
deixar o seu equipamento usado para
reciclagem, é favor contactar os serviços
municipais locais, a entidade de gestão
de resíduos ou os serviços de recolha de
resíduosdomésticos.
O MUSIC Group não se responsabiliza
por perda alguma que possa ser sofrida
por qualquer pessoa que dependa,
seja de maneira completa ou parcial,
de qualquer descrição, fotogra a, ou
declaração aqui contidas. Dados técnicos,
aparências e outras informações estão
sujeitas a modi cações sem aviso prévio.
Todas as marcas são propriedade de seus
respectivos donos. Midas, Klark Teknik,
Lab Gruppen, Lake, Tannoy, Turbosound,
TC Electronic, TC Helicon, Behringer,
Bugera, DDA e TC Applied Technologies
são marcas ou marcas registradas do
MUSIC Group IP Ltd. © MUSIC Group IP Ltd.
2015 Todos direitos reservados.
Para obter os termos de garantia
aplicáveis e condições e informações
adicionais a respeito da garantia
limitada do MUSIC Group, favor veri car
detalhes na íntegra através do website
music-group.com/warranty.
LEGAL RENUNCIANTE
GARANTIA LIMITADA
18 19CT200 Quick Start Guide
CT200 Controls
(13)
(15)(12)(11)(10)(9)
(1) (2) (3) (4)(5) (7) (8)(6) (14)
(21)
(16) (17)
(18) (20)(19)
20 21CT200 Quick Start Guide
(1) Professional locking
connectors (compatible with
Neutrik Speakon) accept 2 and
4-pole cables.
(2) XLR male and female connectors
accept balanced XLR cables.
(3) ¼ TRS/TS connectors accept
balanced and unbalanced
¼ cables.
(4) DISPLAY shows relevant
information about pin connectivity
depending on which mode
is active.
(5) POWER ON/INSTALLED LED lights
solid when the unit is switched on,
and blinks when Installed Cable
Tester mode is selected.
(6) PHANTOM LED lights when more
than 9V is detected between
XLR pins 2 and 3 in Test Tone /
Phantom mode.
(7) GND/SHIELD LED lights when the
ground plug of the XLR OUT socket
connects to the ground pin of the
XLR cable, and lights when the
shield connects at both ends of the
MIDI, CAT-5 or USB cable.
(8) PASS LED lights when all pins
on the output connector are
connected to the respective pins on
the input connector.
(9) CROSSED LED lights when an out
pin is cross-wired to an in pin.
The display will indicate which pin
numbers are crossed.
(10) SHORTED LED lights when a short
circuit is detected between 2 pins.
(11) OPEN LED lights when one end of a
cable pin is not detected.
CT200 Controls
(EN) Step 1: Controls
(12) INTERMITTENT LED lights in
Auto, Manual or Installed Cable
Tester mode when an intermittent
interruption is detected on a pin,
likely indicating a loose connection.
Press the OPTION/RESET button to
reset and test again.
(13) RESET/OPTION button performs
several functions depending
on which mode is active.
See the Operation Modes chapter
for details.
(14) TONE LEVEL switch selects
between +4 dBu, -10 dBV,
and -50 dBV/MIC output level when
using Test Tone mode.
(15) MODE switch selects between
the Cable Tester modes
(default is Auto), Test Tone /
Phantom mode, and powers
the unit o .
(16) USB type A and B connectors
accept standard USB cables.
(17) 1⁄8 TRS/TS connectors accept
balanced and unbalanced
⁄ cables.
(18) RCA connectors accept unbalanced
RCA cables.
(19) RJ45 connectors accept
Ethernet/CAT5 cables.
(20) MIDI connectors accept standard
5-pin DIN cables.
(21) Install 2 AA batteries to
power the unit.
22 23CT200 Quick Start Guide
(ES) Paso 1: Controles
CT200 Controles
(1) Conectores profesionales
con  jación (compatibles con
Neutrik Speakon) que aceptan
cables de 2 y 4 polos.
(2) Conectores XLR macho y
hembra que aceptan cables XLR
balanceados.
(3) Conectores TRS/TS de 6,3 mm
que aceptan cables con clavijas
de 6,3 mm balanceadas y
no balanceadas.
(4) La PANTALLA le muestra
informacn importante relativa
a la conectividad de las distintas
puntas dependiendo del modo que
esté activo en ese momento.
(5) El piloto POWER ON/INSTALLED
se ilumina cuando la unidad
está conectada a la corriente
y encendida y parpadea
cuando está activo el modo
Installed Cable Tester.
(6) El piloto PHANTOM se ilumina
cuando son detectados más de 9V
entre las puntas 2 y 3 de un XLR en
el modo Test Tone / Phantom.
(7) El piloto GND/SHIELD se ilumina
cuando el borne de toma de tierra
de la toma XLR OUT está conectada
a la punta de toma de tierra del
cable XLR y también cuando está
conectada la malla o toma de tierra
en ambos entremos del cable MIDI,
CAT-5 ó USB.
(8) El piloto PASS se ilumina cuando
todas las puntas del conector de
salida están conectadas en las
puntas respectivas del conector
de entrada.
(9) El piloto CROSSED se ilumina
cuando una punta de salida está
cruzada con una punta de entrada.
En la pantalla podrá ver qué
números de puntas están cruzadas.
(10) El piloto SHORTED se ilumina
cuando la unidad ha detectado un
cortocircuito entre 2 puntas.
(11) El piloto OPEN se ilumina cuando
un extremo del cable no es
conectado a una punta.
(12) El piloto INTERMITTENT se
ilumina en los modos Auto,
Manual o Installed Cable Tester
cuando es detectada una
interrupción intermitente en
una punta, lo que indica por lo
general una pérdida de conexión.
Pulse el botón OPTION/RESET para
reiniciar la comprobacn y vuelva a
veri car el cable.
(13) El botón RESET/OPTION realiza
distintas funciones dependiendo
del modo que esté activo en ese
momento. Vea el capítulo que trata
sobre los Modos Operativos para
más detalles.
(14) El interruptor TONE LEVEL le
permite elegir entre un nivel
de salida de +4 dBu, -10 dBV y
-50 dBV/MIC cuando esté usando el
modo Test Tone.
(15) El interruptor MODE le permite
elegir el modo de veri cación
de cable que quiera usar
(por defecto Auto), el modo Test
Tone / Phantom y también le
permite apagar la unidad.
(16) Conectores USB de tipo A y B que
aceptan cables USB standard.
(17) Conectores TRS/TS de 3,5 mm
que aceptan cables con clavijas
de 3,5 mm balanceadas y
no balanceadas.
(18) Conectores RCA que aceptan cables
con clavijas RCA.
(19) Conectores RJ45 que aceptan
cables con clavijas Ethernet/CAT5.
(20) Conectores
MIDI que aceptan
cables con clavijas DIN de
5 puntas standard.
(21) Introduzca dos pilas de tipo AA para
poner en marcha la unidad.
24 25CT200 Quick Start Guide
(FR) Étape 1: Réglages
CT200 Réglages
(1) Les connecteurs professionnels à
verrouillage (compatibles avec les
ches Neutrik Speakon) peuvent
recevoir des câbles à 2 et 4 broches.
(2) Les connecteurs XLR mâle et
femelle sont compatibles avec les
les câbles XLR symétriques.
(3) Les connecteurs Jack 6,35 mm
sont compatibles avec les câbles
Jack 6,35 mm sytriques et
asymétriques.
(4) LAFFICHEUR indique di érentes
informations relatives à la
connectivité des broches
en fonction du mode de
fonctionnement sélectionné.
(5) La LED POWER ON/INSTALLED
sallume en continu lorsque
lappareil est sous tension et
clignote lorsque le mode Installed
Cable Tester est sélectionné.
(6) La LED PHANTOM sallume
lorsquune tension supérieure à
9V est détectée entre les broches
2 et 3 dun câble XLR en mode
Test Tone / Phantom.
(7) La LED GND/SHIELD sallume
lorsque la connexion entre la prise
de terre de lembase XLR OUT et
la broche de terre du câble XLR
est bien e ective. Elle sallume
également lorsque le blindage
de chaque extmité dun câble
MIDI, CAT-5 ou USB est également
bien e ective.
(8) La LED PASS sallume lorsque
chaque broche du connecteur de
sortie est correctement connectée
à la broche correspondante du
connecteur dentrée.
(9) La LED CROSSED sallume
lorsquun court-circuit
transversal est détecté entre des
broches dentrée et de sortie.
La cheur indique le numéro des
broches concernées.
(10) La LED SHORTED sallume
lorsquun court-circuit est détec
entre deux broches.
(11) La LED OPEN sallume lorsqu
une
broche nest pas détece.
(12) Le LED INTERMITTENT sallume
en mode Auto, Manual ou
Installed Cable Tester lorsquune
interruption intermittente est
détectée au niveau dune broche,
ce qui indique généralement un
faux contact. Appuyez sur le bouton
OPTION/RESET pour réinitialiser et
e ectuer un nouveau test.
(13) Le bouton RESET/OPTION
peut activer di érentes
fonctions suivant le mode de
fonctionnement sélectionné.
Consultez le chapitre Modes
de Fonctionnement pour plus
de détails.
(14) Le sélecteur TONE LEVEL permet
de choisir un niveau de sortie
du signal de +4 dBu, -10 dBV
ou -50 dBV lorsque l’appareil
fonctionne en mode Test Tone.
(15) Le sélecteur MODE permet de
choisir le mode de fonctionnement
: les di érents modes Cable
Tester (Auto par défaut), le mode
Test Tone ou le mode Phantom.
Il permet également de mettre
l’appareil hors tension.
(16) Les connecteurs USB de type A et B
sont compatibles avec les câbles
USB standards.
(17) Les connecteurs MiniJack
sont compatibles avec les
câbles MiniJack symétriques
et asymétriques.
(18) Les connecteurs RCA sont
compatibles avec les câbles RCA
asymétriques.
(19) Les connecteurs RJ45 sont
compatibles avec les câbles
Ethernet/CAT5.
(20) Les connecteurs MIDI sont
compatibles avec les câbles MIDI
standards à 5 broches.
(21) Lappareil fonctionne avec
2 piles AA.
26 27CT200 Quick Start Guide
(DE) Schritt 1: Bedienelemente
CT200 Bedienelemente
(1) Professionelle verriegelbare
Anschlüsse (Neutrik Speakon-
kompatibel) akzeptieren 2- und
4-polige Kabel.
(2) XLR-Stecker und –Buchsen
akzeptieren symmetrische
XLR-Kabel.
(3) 6,3 mm TRS/TS-Anschlüsse
akzeptieren symmetrische
und unsymmetrische 6,3 mm
Klinkenkabel.
(4) Abhängig vom aktiven Modus
zeigt das DISPLAY relevante
Informationen über die
Pol-Konnektivität an.
(5) POWER ON/INSTALLED LED
leuchtet beim Einschalten des
Geräts konstant und blinkt, wenn
der Installed Cable Tester-Modus
gewählt ist.
(6) PHANTOM LED leuchtet, wenn im
Test Tone / Phantom-Modus mehr
als 9 Volt zwischen den XLR-Polen 2
und 3 erkannt werden.
(7) GND/SHIELD LED leuchtet, wenn
der Erdungsstift des XLR OUT-
Anschlusses mit dem Erdungspol
des XLR-Kabels verbunden ist und
wenn die Abschirmung an beiden
Enden des MIDI-, CAT-5- oder USB-
Kabels verbunden ist.
(8) PASS LED leuchtet, wenn alle
Pole des Ausgangs mit den
entsprechenden Polen des
Eingangs verbunden sind.
(9) CROSSED LED leuchtet, wenn
ein Ausgangspol mit einem
Eingangspol über Kreuz verdrahtet
ist. Das Display zeigt die Nummern
der kreuzverdrahteten Pole an.
(10) SHORTED LED leuchtet, wenn
zwischen zwei Polen ein
Kurzschluss erkannt wurde.
(11) OPEN LED leuchtet, wenn ein
Polende eines Kabels nicht
erkannt wird.
(12) INTERMITTENT LED leuchtet
im Auto-, Manual- oder Installed
Cable Tester-Modus, wenn
eine zeitweilige Unterbrechung
an einem Pol erkannt wird,
was auf einen Wackelkontakt
hinweist. Drücken Sie die
OPTION/RESET-Taste, um die
Messung zurückzusetzen und
erneut durchzuführen.
(13) RESET/OPTION-Taste führt
je nach aktivem Modus
unterschiedliche Funktionen aus.
Weitere Einzelheiten im Kapitel
„Betriebsarten“.
(14) TONE LEVEL-Schalter wählt
im Test Tone-Modus zwischen
den Ausgangspegeln +4 dBu,
-10 dBV und -50 dBV/MIC.
(15) MODE-Schalter wählt zwischen
den Cable Tester-Modi (Auto ist
voreingestellt) und dem Test Tone
/ Phantom-Modus und schaltet das
Gerät aus.
(16) USB Typ A- und B-Ports
akzeptieren standard USB-Kabel.
(17) 3,5 mm TRS/TS-Anschlüsse
akzeptieren symmetrische
und unsymmetrische 3,5 mm
Klinkenkabel.
(18) Cinch-Anschlüsse akzeptieren
unsymmetrische Cinch-Kabel.
(19) RJ45-Anschlüsse akzeptieren
Ethernet/CAT5-Kabel.
(20) MIDI-Anschlüsse akzeptieren
standard 5-Pol DIN-Kabel.
(21) Um das Gerät zu betreiben,
setzen Sie hier zwei
AA-Batterien ein.
28 29CT200 Quick Start Guide
(PT) Passo 1: Controles
CT200 Controles
(1) Conectores de bloqueio
pro ssionais (compatíveis com
Neutrik Speakon) aceitam cabos de
2 e 4 pólos.
(2) Conectores XLR macho e fêmea
aceitam cabos XLR balanceados.
(3) Conectores ¼ " TRS/TS aceitam
cabos de ¼ " não balanceados
e balanceados.
(4) DISPLAY exibe informações
relevantes sobre a conectividade
do pino, dependendo do modo que
estiver ativo.
(5) O LED POWER ON/INSTALLED
acende uma luz sólida quando a
unidade está ligada, e pisca quando
o modo Installed Cable Tester
estiver selecionado.
(6) O LED PHANTOM acende quando
são detectados mais de 9V entre
os pinos XLR 2 e 3 no modo
Test Tone / Phantom.
(7) O LED GND/SHIELD acende
quando a tomada terra da soquete
XLR OUT se conecta com o pino
terra do cabo XLR, e acende quando
a blindagem se conecta a ambas
extremidades do cabo USB, CAT-5
ou MIDI.
(8) O LED PASS acende quando todos
os pinos no conector de sda estão
conectados aos pinos respectivos
no conector de entrada.
(9) O LED CROSSED acende quando um
pino de saída tem  ação cruzada
com um pino de entrada. O display
indicará quais números de pinos
estão cruzados.
(10) O LED SHORTED acende quando
um curto-circuito é detectado
entre 2 pinos.
(11) O LED OPEN acende quando uma
das extremidades do pino do cabo
não é detectada.
(12) O LED INTERMITTENT acende
nos modos Auto, Manual ou
Installed Cable Tester quando
uma interrupção intermitente é
detectada no pino, provavelmente
indicando conexão frouxa.
Aperte o boo OPTION/RESET
para reiniciar e testar novamente.
(13) O boo RESET/OPTION
desempenha várias funções
dependendo do modo que estiver
ativo. Veri car o capítulo Modos de
Operação para obter detalhes.
(14) O botão TONE LEVEL seleciona
entre os níveis de saída +4 dBu,
-10 dBV, e -50 dBV/MIC quando
estiver usando o modo Test Tone.
(15) O botão MODE faz seleções dentre
os modos Cable Tester (Auto é o
padrão), Test Tone / Phantom,
e desliga a unidade.
(16) Os conectores USB tipo A e B
aceitam cabos USB padrão.
(17) Os conectores TRS/TS de ⁄"
aceitam cabos de ⁄ balanceados e
não balanceados.
(18) Os conectores RCA
aceitam cabos
RCA não balanceados.
(19) Os conectores RJ45 aceitam cabos
Ethernet/CAT5.
(20) Os conectores MIDI aceitam cabos
pado DIN de 5 pinos.
(21) Instale 2 pilhas AA para alimentar
a unidade.
30 31CT200 Quick Start Guide
CT200 Operation Modes
(EN) Step 2: Operation
Modes
Cable Tester (Auto)
To begin an automatic cable test, move
the Mode switch to the Cable Tester
setting. The switch defaults to Auto mode.
Connect a cable to an input and an output.
Press the Reset/Option button to begin
an automated test. The Pass LED will
light if all pins connect properly, and the
maximum pin number will be indicated in
the display. If a bad connection is detected,
the failed pin number will  ash in the
display and an LED will light to indicate
the speci c problem (Shorted, Crossed,
etc.). Shake the cable plugs to check for any
loose connections, which will be indicated
by the Intermittent LED.
Cable Tester (Manual)
To begin a manual cable test, move the Mode
switch to the Cable Tester setting, then hold
the Reset/Option button down for 2 seconds.
The display will blink twice to indicate that
manual mode has been selected. This mode
is similar to Auto, but rather than a fully
automated check where multiple problems
could potentially be displayed with  ashing
pin numbers, each step of the test can
be proceeded manually. Press the Reset/
Option button to clear the Intermittent LED.
Press the Reset/Option button again to check
all pin connections. If a problem is discovered,
only the  rst failed pin numbers will  ash in
the display. Press the Reset/Option button
again to proceed through any other issues.
Installed Cable Tester
When testing cables in  xed installation
environments, it may not be possible to
plug both ends of the cable into the CT200
at the same time. For these situations,
the Installed Cable Tester can check for
short circuits on one end of the cable.
Disconnect the cable that is to be checked
from any other equipment.
Press and hold the Reset/Option button,
move the Mode switch to the Cable Tester
position, then release the Reset/Option
button. The Power On/Installed LED will
ash to indicate that Installed mode is
active. Attach one end of the cable to
the appropriate Out jack on the CT200.
Attach a shorting jack (with pins short
circuited) to the other end of the cable,
or manually short the cable by using a piece
of wire. Check each pair of shorted pins,
which will be indicated by the Shorted LED.
If the LED does not light, there is a break in
the signal  ow and the cable is defective.
Test Tone / Phantom
The CT200 can send a test tone through
a connected cable to check for proper
functionality. Set the Mode switch to the
Test Tone / Phantom setting. Connect an
audio cable (Speakon, XLR, ¼ ", ⁄", RCA)
to the proper Out jack, then connect the
other end to the input of a mixer or speaker.
Select the proper output level with the
Tone Level switch, then press the Reset/
Option button to select the tone frequency.
The display will show LO or HI. If the cable
functions properly, the signal will reach
its destination.
Note – this feature is not available for MIDI,
RJ45, or USB sockets.
The CT200 can also test for phantom
power on XLR cables. Enter Test Tone
/ Phantom mode as described above,
then connect an XLR cable to the XLR Out
jack of the CT200 and to the input of a
mixer or preamp. Engage phantom power
on your source device. The Phantom LED
will light whenever more than 9 volts of
phantom power is detected between XLR
pins 2 and 3.
32 33CT200 Quick Start Guide
CT200 Modos operativos
(ES) Step 2: Modos
operativos
Cable Tester (Auto)
Para hacer que comience una veri cación
de cable automática, coloque el interruptor
Mode en la posición Cable Tester.
El interruptor quedará por defecto en
el modo Auto. Conecte un cable a una
entrada y a una salida. Pulse el botón
Reset/Option para hacer que comience
un test automatizado. El piloto Pass
se iluminará si todas las puntas están
correctamente conectadas y el número de
puntas máximo aparecerá en la pantalla.
Si es detectada una conexn incorrecta,
el número de la punta problemática
parpadeará en la pantalla y se ilumina
un piloto para indicar el problema concreto
detectado (cortocircuito, cruce, etc.).
Mueva un poco los conectores del cable
para comprobar cualquier posible daño o
corte en la conexión, lo que sea indicado
con el piloto Intermittent.
Cable Tester (Manual)
Para hacer que comience una veri cación
de cable manual, coloque el interruptor
Mode en la posición Cable Tester y
mantenga pulsado después el botón
Reset/Option durante 2 segundos. La
pantalla parpadeará dos veces para
indicarle que ha elegido el modo manual.
Este modo es muy similar al Auto, pero
en este caso, en lugar de realizarse un
test totalmente automatizado en el que
pueden ser mostrados varios problemas
potenciales con el parpadeo de los números
de puntas, cada paso del test puede ser
realizado manualmente. Pulse el botón
Reset/Option para hacer que se apague
el piloto Intermittent. Pulse de nuevo el
botón Reset/Option para veri car todas
las conexiones de las puntas. Si la unidad
detecta un problema, en la pantalla solo
parpadeará el número de la primera
punta problemática. Pulse otra vez el
botón Reset/Option para seguir a las
otras comprobaciones.
Installed Cable Tester
Cuando esté veri cando cables en
instalaciones  jas, es posible que no pueda
conectar ambos extremos del cable al
CT200 a la vez. Para este tipo de casos,
el modo Installed Cable Tester puede
veri car posibles cortocircuitos en un
extremo del cable. Desconecte el cable que
vaya a veri car de cualquier otro aparato al
que esté conectado.
Mantenga pulsado el botón Reset/Option
a la vez que lleva el interruptor Mode a
la posición Cable Tester y entonces deje
de pulsar el botón Reset/Option. El piloto
Power On/Installed parpadeará para
indicarle que está activo el modo Installed.
Conecte un extremo del cable a la toma Out
adecuada del CT200. Conecte una clavija
de corte (con puntas cortocircuitadas) al
otro extremo del cable, o cortocircuite
manualmente el cable usando un
lamento. Veri que cada parte de puntas
cortocircuitadas, que sen indicadas
con el piloto Shorted. Si este piloto no se
ilumina, eso indicará que hay un corte real
en la ruta de señal y que por tanto el cable
está averiado.
Test Tone / Phantom
El CT200 puede enviar un tono de prueba
a través de un cable conectado para
veri car su correcta funcionalidad.
Coloque el interruptor Mode en la posición
Test Tone / Phantom. Conecte un cable
audio (Speakon, XLR, 6,3 mm, 3,5 mm,
RCA) a la toma Out adecuada y conecte
después el otro extremo a la entrada de
una mesa de mezclas o altavoz. Elija el
nivel de salida adecuado con el interruptor
Tone Level y pulse el botón Reset/Option
para elegir la frecuencia del sonido.
En la pantalla aparecerá LO o HI. Si el cable
funciona correctamente, la señal llegará a
su destino.
Nota – esta función no está disponible para
las tomas MIDI, RJ45 o USB.
El CT200 también puede veri car la
alimentación fantasma de los cables XLR.
Elija el modo Test Tone / Phantom como le
hemos descrito antes y conecte desps
un cable XLR a la toma XLR Out del CT200
y a la entrada de una mesa de mezclas o
previo. Active la alimentación fantasma
en su dispositivo fuente. El piloto Phantom
se iluminará siempre que sean detectados
más de 9 V entre las puntas XLR 2 y 3.
34 35CT200 Quick Start Guide
CT200 Modes de fonctionnement
(FR) Step 2: Modes de
fonctionnement
Cable Tester (Auto)
Pour lancer un test de câble automatisé,
placez le sélecteur Mode sur Cable Tester.
Par défaut, le mode Auto est activé.
Connectez un câble à une entrée et à
une sortie. Appuyez sur le bouton Reset/
Option pour démarrer le test automatisé.
La LED Pass sallume si les connexions entre
chaque broche sont correctes, et le chi re
correspondant au nombre de broches
teses est alors indiqué sur la cheur.
Si une mauvaise connexion est détece,
le numéro de la broche correspondante
clignote et la LED correspondant au
problème rencontré sallume (LED Shorted,
Crossed, etc.). Bougez les  ches du câble
a n de détecter des faux contacts (indiqués
par la LED Intermittent).
Cable Tester (Manuel)
Pour lancer un test de câble manuel, placez
le sélecteur Mode sur Cable Tester puiis
maintenez le bouton Reset/Option enfon
pendant 2 secondes. La cheur clignote
deux fois pour indiquer que le mode manuel
est sélectionné. Ce mode fonctionne de
manière similaire au mode Auto, mais au
lieu dun test entièrement automatisé
au cours duquel plusieurs problèmes
peuvent être indiqs par le chi re
correspondant aux broches clignotant
sur la cheur, chaque étape du test est
e ectuée manuellement. Appuyez sur le
bouton Reset/Option pour réinitialiser le
mode Intermittent. Appuyez à nouveau
sur le bouton Reset/Option pour véri er
la connexion de chaque broche. Si un
problème est détecté, seuls les chi res
correspondant aux premières broches
défectueuses détectées clignotent sur
la cheur. Appuyez sur le bouton Reset/
Option à nouveau pour examiner les
autres problèmes.
Installed Cable Tester
Si vous souhaitez tester un câble dans
une installation  xe, il est possible que
vous ne puissiez pas connecter les deux
extrémités de ce câble simultanément
au CT200. Dans ce genre de situation,
la fonction Installed Cable Tester peut
rechercher les courts-circuits présent dans
lune des extmités du câble. Vous devez
préalablement déconnecter le câble de tout
autre appareil.
Maintenez le bouton Reset/Option enfoncé,
placez le sélecteur Mode sur Cable Tester,
puis relâchez le bouton Reset/Option.
La LED Power On/Installed clignote pour
indiquer que le mode Installed est activé.
Connecter une extrémité du câble à la
sortie appropriée du CT200. Connectez
une  che dont les broches ont été court-
circuitées (interconneces) à lautre
extrémité du câble, ou court-circuitez
manuellement le câble avec un morceau
de  l électrique. Véri ez chaque paire de
broches interconnectées, indiquées par
la LED Shorted. Si la LED ne sallume pas,
cela signi e que le signal ne peut pas
circuler et donc que le câble est défectueux.
Test Tone / Phantom
Le CT200 peut envoyer un signal
test dans le câble pour véri er son
fonctionnement correct. Placez le
sélecteur Mode sur Test Tone / Phantom.
Connectez un câble audio (Speakon, XLR,
Jack 6,35 mm, MiniJack, RCA) à la sortie
correspondante, puis connectez lautre
extrémité à lentrée dune console de
mixage ou dune enceinte. Sélectionnez le
niveau de sortie approprié avec le sélecteur
Tone Level, puis utilisez le bouton Reset/
Option pour sélectionner la fquence du
signal. La cheur indique LO ou HI. Si le
signal est transmis, cela signi e que le
ble fonctionne correctement.
Remarque – cette fonction nest
pas disponible pour les câbles MIDI,
RJ45 ou USB.
Le CT200 peut également véri er si la
tension fantôme circule correctement
dans un câble XLR. Passez en mode
Test Tone / Phantom comme indiqué
ci-dessus, puis connectez un câble XLR
à la sortie du CT200 ainsi quà lentrée
dune console de mixage ou dun préampli.
Activez lalimentation fantôme de votre
appareil source. La LED Phantom sallume
dès quune tension fantôme supérieure à
9 V est détectée entre les broches 2 et 3.
36 37CT200 Quick Start Guide
CT200 Betriebsarten
(DE) Step 2: Betriebsarten
Cable Tester (Auto)
Um einen automatischen Kabeltest zu
starten, schieben Sie den Mode-Schalter
auf „Cable Tester. Der Auto-Modus ist
voreingestellt. Schließen Sie ein Kabel
an einen Eingang und Ausgang an.
Drücken Sie die Reset/Option-Taste,
um den automatisierten Test zu starten.
Wenn alle Pole korrekt angeschlossen
sind, leuchtet die Pass LED und die
maximale Pol-Anzahl wird auf dem
Display angezeigt. Wird eine fehlerhafte
Verbindung erkannt, blinkt die Nummer
des betre enden Pols auf dem Display und
eine leuchtende LED zeigt das spezielle
Problem an (Shorted/kurzgeschlossen,
Crossed/kreuzverdrahtet etc.). Wackeln Sie
an den Kabelsteckern, um Wackelkontakte
aufzuspüren, die von der Intermittent LED
angezeigt werden.
Cable Tester (Manual)
Zum Starten eines manuellen Kabeltests
schieben Sie den Mode-Schalter auf
„Cable Tester“ und halten die Reset/
Option-Taste zwei Sekunden gedrückt.
Das Display blinkt zweimal und zeigt damit
an, dass der manuelle Modus gewählt
wurde. Dieser Modus ist mit „Auto
vergleichbar, nur werden hier nicht wie bei
der vollautomatischen Prüfung mehrere
potenzielle Probleme mit blinkenden
Pol-Nummern der Reihe nach automatisch
angezeigt, sondern man kann jeden
Schritt des Tests manuell durchgehen.
Drücken Sie die Reset/Option-Taste,
um die Intermittent LED auszuschalten.
Drücken Sie nochmals die Reset/Option-
Taste, um alle Pol-Verbindungen zu prüfen.
Wenn ein Problem erkannt wird, blinken
nur die Nummern der ersten fehlerhaften
Pole auf dem Display. Drücken Sie nochmals
die Reset/Option-Taste, um alle anderen
Probleme durchzugehen.
Installed Cable Tester
Wenn man Kabel in Festinstallationen testet,
kann man eventuell nicht beide Kabelenden
gleichzeitig an den CT200 anschließen.
In diesen Fällen kann man mit „Installed
Cable Tester“ an einem Kabelende nach
Kurzschlüssen suchen. Trennen Sie das zu
prüfende Kabel von allen anderen Geräten.
Halten Sie die Reset/Option-Taste gedrückt,
schieben Sie den Mode-Schalter auf „Cable
Tester“ und lassen Sie dann die Reset/
Option-Taste los. Die Power On/Installed
LED blinkt und zeigt damit an, dass der
Installed-Modus aktiv ist. Verbinden Sie ein
Kabelende mit der geeigneten Out-Buchse
des CT200. Befestigen Sie eine Kurzschluss-
Buchse (mit kurzgeschlossenen Polen) am
anderen Kabelende oder schlien Sie das
Kabel manuell mit einem Stück Draht kurz.
Prüfen Sie jedes Paar kurzgeschlossener
Pole und achten Sie auf die Shorted
LED-Anzeige. Wenn die LED nicht leuchtet,
ist der Signal uss unterbrochen und das
Kabel ist defekt.
Test Tone / Phantom
Um die korrekte Funktion eines
angeschlossenen Kabels zu prüfen,
kann der CT200 einen Testton durch das
Kabel leiten. Stellen Sie den Mode-Schalter
auf „Test Tone / Phantom“. Schließen
Sie ein Audiokabel (Speakon, XLR,
6,3 mm Klinke, 3,5 mm Klinke, Cinch)
an die entsprechende Out-Buchse an und
verbinden Sie das andere Kabelende mit
einem Mischer oder Aktivlautsprecher.
Stellen Sie mit dem Tone Level-Schalter
den geeigneten Ausgangspegel ein und
drücken Sie dann die Reset/Option-
Taste, um die Tonfrequenz zu wählen.
Auf dem Display wird LO oder HI angezeigt.
Wenn das Kabel korrekt funktioniert,
wird das Signal sein Ziel erreichen.
Hinweis – diese Funktion ist nicht für
MIDI-, RJ45- oder USB-Anschlüsse nutzbar.
Der CT200 kann XLR-Kabel auch auf
Phantomspannung überprüfen.
Schalten Sie wie oben beschrieben in den
Test Tone / Phantom-Modus und schließen
Sie dann ein XLR-Kabel an die XLR Out-
Buchse des CT200 und an den Eingang
eines Mischers oder Vorverstärkers an.
Aktivieren Sie an Ihrem Quellenget
die Phantomspannung. Wenn mehr
als 9 Volt Phantomspannung zwischen
den XLR-Polen 2 und 3 erkannt wird,
leuchtet die Phantom LED.
38 39CT200 Quick Start Guide
CT200 Modos de Operação
(PT) Step 2: Modos de
Operação
Testador de Cabo (Auto)
Para comar um teste de cabo automático,
coloque o botão Mode em Cable Tester.
O pado do boo é o modo Auto.
Conecte um cabo a uma entrada e uma
saída. Aperte o botão Reset/Option para
comar um teste automático. O LED Pass
acenderá se todos os pinos estiverem
conectados de maneira adequada, e o
número de pinos máximo será indicado
no display. Se for detectada uma conexão
ruim, o número de pino que estiver com a
falha piscará no display e um LED acenderá
para indicar o problema espe co
(Curto, Cruzamento, etc.). Sacuda os
plugues do cabo para veri car se há alguma
coneo solta, isso será indicado pelo
LED Intermittent.
Testador de Cabo (Manual)
Para comar o teste de cabo manual,
coloque o botão Mode em Cable Tester,
então aperte e mantenha o botão Reset/
Option apertado por 2 segundos. O display
piscará duas vezes para indicar que o
modo manual foi selecionado. Este modo
é parecido com o Auto, mas em vez de uma
veri cão completamente automatizada
onde problemas múltiplos podem ser
potencialmente exibidos com números
de pinos piscando, cada etapa do teste
pode ser procedida manualmente.
Aperte o botão Reset/Option para remover
o LED Intermittent. Aperte o botão Reset/
Option novamente para veri car todas as
conexões de pinos. Se um problema for
descoberto, somente os números de pino
que falharam primeiro piscarão no display.
Aperte o boo Reset/Option novamente
para proceder para outros problemas.
Testador de Cabo Instalado
Ao se fazer testes de cabos em ambientes
de instalação  xa, pode não ser possível
conectar ambas extremidades do cabo no
CT200 ao mesmo tempo. Nesses casos,
o Installed Cable Tester pode veri car
curto-circuitos em uma extremidade do
cabo. Desconecte o cabo que será veri cado
de qualquer outro equipamento.
Aperte e mantenha apertado o botão
Reset/Option, coloque o botão Mode na
posão Cable Tester e então solte o botão
Reset/Option. O LED Power On/Installed
piscará para indicar que o modo Installed
está ativo. Conecte uma extremidade do
cabo ao jack Out apropriado no CT200.
Conecte um jack em curto-circuito
(com pinos em curto-circuito) à outra
extremidade do cabo, ou fa o curto
manualmente no cabo usando um  o.
Veri que cada par de pinos em curto,
que estarão indicados pelo LED Shorted.
Se o LED não acender, há uma quebra no
uxo do sinal e o cabo está defeituoso.
Test Tone / Phantom
O CT200 é capaz de enviar um tom de
timbre através de um cabo conectado
para veri car a funcionalidade adequada.
Coloque o botão Mode em Test Tone /
Phantom. Conecte um cabo de áudio
(Speakon, XLR, ¼ ", ⁄", RCA) ao jack
Out apropriado, então conecte a outra
extremidade à entrada do misturador ou
alto-falante. Selecione o nível de saída
apropriado com o botão Tone Level,
então aperte o botão Reset/Option
para selecionar a frequência do timbre.
O display exibirá LO ou HI. Se o cabo estiver
funcionando adequadamente, o sinal
chegará ao seu destino.
Nota – este recurso não está disponível
para tomadas MIDI, RJ45, ou USB.
O CT200 também é capaz de testar a
alimentão fantasma nos cabos XLR.
Insira o modo Test Tone / Phantom
conforme descrito acima, então conecte
um cabo XLR ao jack XLR Out do CT200 e à
entrada do misturador ou pré ampli cador.
Habilite a alimentação fantasma no seu
dispositivo fonte. O LED Phantom acende
quando mais de 9 volts de alimentação
fantasma for detectada entre os pinos
XLR 2 e 3.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25

Behringer CT200 Guide de démarrage rapide

Taper
Guide de démarrage rapide