brondell UF-15 Manuel utilisateur

Catégorie
Articles sanitaires
Taper
Manuel utilisateur

Ce manuel convient également à

OWNER’S MANUAL
UC300 Three-Stage Undercounter Water Filtration System
UC100 Single-Stage Undercounter Water Filtration System
North America
1
CONTENTS
Read this Owners Manual for correct installation, use and maintenance
of this product. After reading and completing installation, keep this
manual in a place that is easily accessible.
PRODUCT INSTALLATION
09 TVALVE INSTALLATION
10 FAUCET INSTALLATION
12 FILTER HEAD
CONNECTION
ASSEMBLY INSTALLATION
13 INSTALLING THE FILTERS
14 CONNECTING THE TUBING
Using “Quick Connectors
15 PREPARING FOR USE
GENERAL INFO
02 SAFETY INFORMATION
03 TDS METER INFORMATION
04 FEATURES
05 UC
300
PRODUCT COMPONENTS
06 UC
100
PRODUCT COMPONENTS
07 UC
300
WATER FLOW DIAGRAM
08 UC
100
WATER FLOW DIAGRAM
MAINTENANCE
16 FILTERS & FILTER CHANGE INDICATOR
Filters
Filter Change Indicator
Filter Replacement Cycle
17 REPLACING THE FILTERS
19 TROUBLESHOOTING
TECHNICAL INFO
20 PRODUCT SPECIFICATIONS
21 UC
300/
UC
100
PERFORMANCE DATA SHEET
24 WARRANTY
25 CONTACT BRONDELL
26 SPANISH VERSION
53 FRENCH VERSION
2
SAFETY INFORMATION
Be careful to keep this safety information. Please read this information to
prevent property loss and ensure safety.
DANGER: If not observed, serious injury or even death may occur as a result.
WARNING: If not observed, serious physical injury or property damage may occur as a result.
Read all the instructions before using or installing the Coral UC300/UC100.
Never disassemble, repair or reconstruct the lter head housing. This may cause the product
to fail.
Never unscrew the lters while the product is in use. This may cause failure due to high water
pressure, or it may cause a water leak.
Do not install near radiators. This may cause re, or the product could be damaged, resulting
in leakage.
CAUTION: If not observed, minor physical injury or property damage may occur as a result.
For California Residents: CR2032 batteries contain Perchlorate Material - special handling
may apply. Visit http://www.dtsc.ca.gov/hazardouswaste/perchlorate for more information.
Use or place the unit on a level area and do not apply force to the unit. This may cause physi-
cal injury and/or damage to the product that may void your warranty.
Turn the water supply valve o if the lter system will not be used for an extended period
of time.
Especially during very cold weather, the water pressure may rise and may cause a water leak.
Replace the lters according to their scheduled replacement intervals. If one or more of the
lters are exhausted, the purication quality will diminish.
When replacing the lter or moving the product, do not pull on the water supply hose. The
water supply hose may become detached, damaged, or the quick connection coupling may
be weakened.
If a water leak occurs while using the product, or the area around the product is wet,
turn the water supply valve o immediately.
3
The Coral Undercounter Water Filtration System is not designed to remove benecial
minerals from your drinking water. These minerals that occur naturally are a healthy
part of your drinking water and should remain. The Brondell Coral Undercounter
Water Filtration System is designed to dramatically reduce water-soluble harmful
contaminants, including industrial chemicals, pesticides, herbicides, turbidity,
volatile organic compounds (VOCs), and microorganisms, most of which cannot be
"read" with a TDS reader.
Since these harmful components are water-soluble, they cannot be picked up by a
simple TDS meter. Contrary to its name (Total Dissolved Solids or TDS Meter), these
inexpensive products cannot detect most harmful water-soluble contaminants.
There is a major misconception that low TDS readings mean healthy water and that
is simply not always true.
The best method for testing the performance of a water ltration device is to have
a nationally recognized independent organization,such as WQA (Water Quality
Association) or NSF International,test and certify the products. The certied data
is then available in a Performance Data Sheet, which you should request from the
manufacturer. For more clarication of what the Coral Undercounter Water Filtration
System does remove from your water, please see our Certied Performance Data
Sheets on pages 21-23.
IMPORTANT NOTE ABOUT
“TDS METERS” AND TESTERS
Q) When I use a Total Dissolved Particle (TDS) reader to test my water
after it goes through the Coral Undercounter Water Filtration System,
why don't the levels of dissolved particles go down or decrease? I don’t
think the product is working.
4
BRONDELL H2O+ CORAL FEATURES
Superior Filtration Performance
Best in class water ltration for a healthy home and family
Elegant Chrome Faucet with Integrated LED
Filter Change Indicator
Simple intuitive LED indicator reminds you when it’s time to change
your lters
Easy Quick Change Filter Replacement
Brondell’s special “twist & seal” lter system makes changing your lters
a breeze
One Year (UC300) or Six Month (UC100) Filter Lifespan
Simplied maintenance and low cost of operation
Easy DIY Installation
Pre-installed faucet tubing and quick-connect water supply connections
simplies installation
WQA Gold Seal Certied Filtration Technology
Filtration performance claims you can trust!
One Year Manufacturers Warranty
Backed by Brondell’s commitment to superior customer service
and support
5
UC300 PRODUCT COMPONENTS
Water Supply Tubing
Filter Head
Connection Assembly
3 Filters:
Sediment Filter
Pre-Carbon Filter
Carbon Block Filter
LED Indicator Faucet
Assembly with attached
tubing (blue)
Water Supply T-Valve
with Rubber Washer
(3/8” connection)
T-Valve Adapters
with Rubber Washer
3/8” to 1/2”
Quick Connect
90° Elbows
Mounting Screws
6
UC100 PRODUCT COMPONENTS
Filter Head
Connection Assembly
1 Filter:
Carbon Block Filter
Water Supply Tubing
LED Indicator Faucet
Assembly with attached
tubing (blue)
Water Supply T-Valve
with Rubber Washer
(3/8” connection)
T-Valve Adapters
with Rubber Washer
3/8” to 1/2”
Quick Connect
90° Elbows
Mounting Screws
7
UC300 WATER FLOW DIAGRAM
Sediment
Filter
Pre-Carbon
Filter
Carbon
Block Filter
Incoming
Water
INLET
Filtered
Water
OUTLET
– REAR VIEW –
Tap Faucet
LED Indicator
Faucet
Filtered
Water Tubing
Water Supply
Tubing
Sediment Filter
Sink
Pre-Carbon Filter
Carbon Block Filter
Filter Head Connection
Assembly
Water Supply
T-Valve
Cold Water
Supply
8
UC100 WATER FLOW DIAGRAM
Carbon
Block Filter
Incoming
Water
Filtered
Water
– REAR VIEW –
Tap Faucet
LED Indicator
Faucet
Water Supply
Tubing
Sink
Carbon Block Filter
Filter Head Connection
Assembly
Water Supply
T-Valve
Filtered
Water Tubing
Cold Water
Supply
INLETOUTLET
9
PRODUCT INSTALLATION
STEP 1: TVALVE INSTALLATION
Do not install the Filter Head Connection Asssembly further than 12 feet away from
either the water supply valve, or the Indicator Faucet.
Avoid unnecessary slack in the supply hoses when connecting to the water supply, Filter
Head Connection Assembly, or Indicator Faucet.
Do not install in direct sunlight, or a place where it will be directly exposed to freezing
temperatures.
Be sure to install the T-Valve on the cold water supply line. Running hot water through
the Coral Water Filtration System will damage the lters.
1. Close the cold water supply valve. Place a bucket, or similar
item, underneath the valve to catch any water that may spill
out during installation.
2. Unscrew the hose that connects the cold water supply valve
to the existing tap water faucet.
3. Ensure the rubber washer is inside the T-Valve, and then
screw the T-Valve Adapter onto the cold water supply valve.
NOTE: If the water supply valve is larger than the 3/8”
connection on the T-Valve, use the included 1/2” Valve
Adapters with Rubber Washers to connect the T-Valve and
the water supply hose.
4. Screw the cold water supply hose to the top of the T-Valve.
Be sure to keep the water supply valve closed.
10
STEP 2: FAUCET INSTALLATION
Before Installation
You will need an existing faucet hole at least 7/16
inches in diameter in the sink or countertop to install
the supplied ltered water faucet. You may also
replace an existing kitchen sprayer, soap dispenser,
or plug already on the countertop or sink.
1. Unpack the faucet and insert the Top Spout into the Main
Body by pushing down until inserted then screw the Top Cap
clockwise until secured in place.
2. Cut zip tie on the blue water connection tubing and unroll
to straighten tubing. Be careful not to cut the tube when
removing the zip tie.
If drilling a new hole is required for the
faucet installation, please consult a
professional. Brondell will not be liable
for any damages including those to the
sink or countertop due to installation of
the faucet or drilling a hole.
Please nd answers to Frequently Asked
Questions (FAQs) and installation videos
on brondell.com
For California Residents: CR2032
batteries contain Perchlorate Material -
special handling may apply. Visit http://
www.dtsc.ca.gov/hazardouswaste/
perchlorate for more information.
Locking Nut
Plastic Washer
(raised area faces down)
Top Spout
Top Cap
Main Body
Lock Washer
Counter Top
1/4" Tube
(connected to faucet)
Escutcheon
LED Indicator
Battery Seat
CR2032
Battery
PRODUCT INSTALLATION (cont.)
11
3. Attach the Escutcheon to the Main Body by inserting the blue
tubing through the Escutcheon and pushing it all the way up
until connected to the Main Body.
4. Install the faucet on top of the countertop or sink and feed
the blue tubing through the hole to the cabinet below. Then
slide the large Plastic Washer as shown up through the blue
tubing until snug against the bottom of the countertop or
sink hole.
Be sure that the at part of the Plastic Washer is facing up
and the raised area is facing down, as shown to the right.
5. Install the Lock Washer and the Locking Nut the same way
and tighten until the plastic washer is holding the faucet
assembly rmly in place. The faucet is now installed.
6. Pull the plastic tab out from the battery compartment to
activate the faucet indicator. The LED light will blink red
once, blue once, and then will be ready to go.
**IMPORTANT** Be sure that the at side of the
Plastic Washer is facing up and the raised area is
facing down, as shown below.
RAISED AREA FACES DOWN
FLAT SIDE FACES UP
12
STEP 3: FILTER HEAD CONNECTION ASSEMBLY INSTALLATION
Be sure to install the Filter Head Connection Assembly so that the top of the assembly
is at least 14 inches from the oor of the sink cabinet. Otherwise the lters will not
install or seat correctly.
2. Using a pencil, mark where the Filter Head Connection Assembly will be mounted to the
sidewall of the cabinet (at least 14” from the cabinet oor). Use a level to make sure that the
Assembly will be mounted straight.
NOTE: Before you mount the Connection Assembly, it may be a good idea to practice inserting
and removing the lters.
3. Insert the two mounting screws through the holes in the Assembly frame and screw into the
cabinet sidewall.
1. Attach the two Quick Connect 90° Elbows to back side of the Connection Assembly Inlet and
Outlet as shown
UC300 UC100
UC300 UC100
PRODUCT INSTALLATION (cont.)
14 inches
14 inches
13
STEP 4: INSTALLING THE FILTERS
1. To insert the lters, rst line up the arrow on the lter head
with the arrow on the lter
NOTE: For purchasers of the Coral UC300, it is very important to install the lters in the correct
order. Simply match the same label colors to the lter head labels. From left-to-right, the
proper order is
1) Sediment lter
2) Pre-Carbon lter
3) Carbon Block lter
2. With the top and bottom arrows
still lined up, insert the top
of the lter into the housing
and turn 90 degrees to the
right, until the lter will not
turn any more.
The Filter Head arrow should
now be lined up with the “Circle
icon and notch on the top
of the lter.
3. For UC300 – Repeat the process for the Pre-Carbon lter and Carbon Block lter.
For UC100This process is complete.
UC300 UC100
water outlet
water inlet
14
STEP 5: CONNECTING THE TUBING
1. Water Supply Connection
Use the supplied white Water Supply Tubing to connect the T-valve to the Filter Head Connector
Assembly by pushing one end of the tubing rmly into the Quick Connector
Collette on the open side of the T-Valve. Be sure to push in all the way and ensure the Tube
is not bent or kinked.
Then connect the other open end of the Tubing to the Filter Head Connector Assembly “Inlet”
by inserting the tube into the Collette on the Quick Connect 90° Elbow on the side labeled
“Inlet”.
Using "Quick Connectors"
Tube connections on the T-Valve, Filter Head Connection Assembly, and Indicator Faucet are all of
the “Quick Connect” variety. The steps below illustrate how to connect and disconnect the Tubes
from these connectors.
a. Push the Tube into the Collette. The Collette is a collar that
provides a secure t for the Tube and prevents water leaks.
b. Push the Tube in until it stops. The Tube will be secure, and
resistant to tugs or pulls. The Collette will be rigid and raised
slightly from the connector housing.
c. To disconnect the Tube, push down and hold the Collette rst,
and then pull the Tube out gently.
2. Faucet Connection
Now, connect the open end of the Blue Tubing coming from the Faucet to the Filter Head
Connector Assembly Outlet by inserting the Tube into the Collette on the Quick Connect 90°
Elbow on the side labeled Outlet. Be sure to push in rmly all the way and ensure the Tube is
not bent or kinked.
Connector
Housing
Tube
Collette
a
c
b
Visit brondell.com for our Quick Connect Tutorial video.
PRODUCT INSTALLATION (cont.)
15
PREPARING FOR USE
TURN ON WATER & CHECK FOR LEAKS
FLUSHING THE SYSTEM
1. Turn on water supply
a. Open the T-Valve by turning the valve arm 90° as shown.
b. Turn the cold water supply valve at the wall counter-
clockwise to turn on. The cold water supply will then
begin to supply water to the Coral UC300 or UC100.
2. Checking for leaks
a. Once the water supply has been turned on, check for any
signs of leaking throughout the system.
b. If no leaks are found, wait 5 minutes and check one more
time. If still no leaking, then continue to next step to ush
the system.
1. Turn the Indicator Faucet on and let the water ow from the faucet for 5 minutes continuously to
ush the system and activate the lter(s).
2. Check one last time for any leaks during this process.
3. Your Coral system is now ready to use!
Before turning the cold water valve back on, review the installation instructions to
ensure that the T-Valve and water hoses are connected correctly and securely.
Failure to properly install this product or to properly check for leaks may cause damage
to the property. In these instances, Brondell, Inc. will not be held responsible for any
damages.
16
FILTERS
FILTER CHANGE INDICATOR
FILTER REPLACEMENT CYCLE
Contact Brondell at 888-542-3355, or visit us at www.brondell.com to order replacement lters.
The lters are critical to the performance of the Coral UC Water Filtration system, and it is
important to replace all of the lters on a regular basis. If any of the lters are overused beyond the
recommended service life, the performance of the water ltration device can deteriorate. Do not
miss the lter replacement cycle or use non-compatible lters as this can aect system performance
or damage the unit.
The LED lter change indicator in the faucet works by tracking both time and water ow from the
Coral UC system.
UC300When 12 months have elapsed or 600 gallons of water has been ltered through the system
(whichever comes rst), the LED will ash red when dispensing water instead of ashing blue.
UC100When 6 months have elapsed or 300 gallons of water has been ltered through the system
(whichever comes rst), the LED will ash red when dispensing water instead of ashing blue.
When the faucet LED indicator begins to ash red, it’s now time to change the lters and reset the
faucet indicator by replacing the battery.
A new battery is always included with the UF-35, or UF-15 lter replacement set.
* The lter replacement frequency may be increased for areas with poor water quality or
greater use. The period for the lter exchange is based on an average production of 1.64
gallons of drinking water per day.
FILTERS & FILTER CHANGE INDICATOR
Part Number Filter Name Usable period*
UF35
Sediment Filter 12 months
Pre-Carbon Plus Filter 12 months
Carbon Block Filter 12 months
UF-15 Carbon Block Filter 6 months
UC300
UC100
17
MAINTENANCE
REPLACING THE FILTERS
1. Close the T-Valve under the sink to shut o the ow of water
to the Coral.
2. Once the T-valve is shut o, turn the Indicator Faucet on all
the way and keep it on until all the residual water in the
tubes has been expelled.
4. Install the new lter(s). Review the procedure outlined on Page 13.
5. Open the T-Valve to restore the ow of water and turn the Indicator Faucet on for 5 minutes
continuously to ush and activate the new lter(s).
Be sure to reset the Indicator Faucet by following the next steps.
3. Turn the lter(s) to be replaced 90° to the left, until the lter
comes out of the Filter Head Connection Assembly.
For UC300, remove the remaining two lters.
For UC100, the process is complete.
18
6. Replace the battery in the faucet LED indicator to reset
the lter change reminder. The battery type is CR2032
and Brondell provides one with every set of UF-35 and
UF-15 lters.
a. Under the faucet handle, locate the black rubber battery
compartment. Grasp it from the sides and pull down as
shown.
b. Remove the old battery from the compartment by lifting
the silver metal tab and sliding the battery out of the
rubber casing. Wait 30 seconds for the residual energy to
drain to reset the indicator.
c. Replace with a new CR2032 battery by sliding the battery
under the silver tab, making sure that the words on the
battery are facing out. A fresh CR2032 battery comes with
every UF-35 and UF-15 Replacement Filter pack.
d. Push the black rubber battery compartment back up into
the faucet handle.
e. The indicator will blink red once, blue once, and then the
indicator will function as normal.
MAINTENANCE (cont.)
REPLACING THE FILTERS (cont.)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82

brondell UF-15 Manuel utilisateur

Catégorie
Articles sanitaires
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues