97329C (Rev. L - 6/09)
WM16WQ*1D
PAGE 4
FAN
10
12
M
13
C
S
2
GND
COLD CONTROL
(WATER)
WHT
BLK
11
3
1
14
OVERLOAD
COMPRESSOR
RELAY
ITEMIZED PARTS LIST
ITEM NO. PART NO.
DESCRIPTION
51544C
102639931640
160270508640
28340C
75561C
66506C
31513C
35762C
31027C
194243901550
31797C
45697C
66799C
101453431640
101507531550
75494C
55860C
75589C
66202C
66229C
36208C
15005C
26860C
26861C
26862C
50986C
61314C
55996C
45670C
75588C
55913C
56159C
70682C
See Color Table
See Color Table
56092C
70683C
See Color Table
400660943730
Bubbler
Drain Plug
Strainer Plate
Basin
Fitting-Elbow 3/8 x 3/8 NPT x 90
Evaporator
Cold Control
Compressor Serv. Pak
Overload/Relay
Electrical Shield
Relay Cover
Precooler Assy
Condenser Assy
Cap Push Button
Push Button Stem
Check Valve
Regulator Bracket
Gasket
Drier
Heat Exchanger
Power Cord
Regulator Retaining Nut
Regulator Lever
Pivot Bracket
Regulator Retaining Bracket
Regulator Holder
Regulator
Strainer
Vacuum Break
Nut - Slip Joint 1-1/4
Adaptor - Drain
Nipple - Bubbler
Tee - 1/4
Side Panel - Right
Side Panel - Left
Poly Tubing (Cut To Length)
Union - 1/4
Front Panel
Hanger Bracket
1
2
3
4
5
6
7
8*
9
10
11
12**
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
-
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE
WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the above water coolers or
orders for repair parts MUST include Model No. and Serial No. of cooler, name
and part number of replacement part.
2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
PRINTED IN U.S.A.
CONDENSER WATER VALVE ADJUSTMENT
The condenser water valve is factory preset for a condenser water
outlet temperature of 95° to 105° F.
If actual temperature varies greatly from this, readjust water flow rate
at the valve using the following procedures.
1. START UP COMPRESSOR
This can be accomplished by depressing the cooler push button
(See Fig. 1 - Item 14). Keep water running during the entire
readjustment procedure.
2. ADJUSTMENT CONDENSER WATER VALVE
Adjust valve by rotating adjustment stem. Rotating stem clockwise will
decrease water flow. Counterclockwise rotation will increase water
flow. Increasing water flow will result in a lower condenser outlet
temperature, while decreasing water flow will result in a higher outlet
temperature. Proper adjustment is attained when condenser outlet
temperature is 95° to 105° F.
WIRING DIAGRAM
This drawing is merely for illustrating the
components of the electrical system.
FIG. 6
COLOR
ITEM 35
Platinum (PV)
Slate (SV)
Stainless Steel (SS)
401432248410
401432248440
401432242830
ITEM 38
401483948410
401483948440
401483942830
ITEM 34
401484048410
401484048440
401484042830
**Includes items 18, 30, & 31
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620