Halsey Taylor WM16W.C Le manuel du propriétaire

Taper
Le manuel du propriétaire
WM16W-Q*1C
PAGE 1 97043C(Rev. B - 4/98)
HALSEY TAYLOR OWNERS MANUAL
USES HFC-134A REFRIGERANT
FIG. 1
2, 3
4
SEE FIG. 5
1
14,15
8, 9,10,11
19
6
20
16
32
13
29
12,30,31
7
21
28
33
5,18
SEE FIG. 6
SEE FIG. 4
97043C(Rev. B - 4/98)
WM16W-Q*1C
PAGE 2
WALL FACE
SUPERFICIE DE LA PARED
MUR
FIG. 2
E = INSURE PROPER VENTILATION BY MAINTAINING 4" (102mm) MIN. CLEARANCE FROM CABINET LOUVERS TO WALL.
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 4" (102mm) MÍN. DE HOLGURA ENTRE LA
REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 4" (102mm) MIN. ENTRE LES ÉVENTS DE LENCEINTE ET LE MUR.
F = POWER CORD 4' (1219mm) LONG
CABLE ELÉCTRICO DE 4' (1219mm), DE LARGO
CORDON DALIMENTATION 4' (1219mm)
G = 1/4" (6mm) SCREW HOLES IN MOUNTING PLATE
AGUJEROS DE TORNILLO 1/4" (6mm) EN LA PLACA DE MONTAJE
TROUS DE VIS 1/4" (6mm) DANS LA PLAQUE DE MONTAGE
FINISHED FLOOR
PISO ACABADO
PLANCHER FINI
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB OUT 1-1/2 IN.
(38mm) FROM WALL SHUT OFF BY OTHERS
SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIÁM.
EXT. A 1-1/2" (38 mm) FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS.
EMPLACEMENT RECOMMANDÉ D'ALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5
mm) D.E. CONNECTANT UNE TUYAUTERIE DE 1-1/2 PO. (38 mm) DEPUIS LE ROBINET D'ARRÊT FOURNI PAR
D'AUTRES.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4 O.D. DRAIN
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼ DE DIÁMETRO.
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE DEAU.
C = 1-1/4 TRAP NOT FURNISHED
PURGADOR DE 1¼ NO PROPORCIONADO
SIPHON 1-1/4 NON FOURNI
D = ELECTRICAL OUTLET LOCATION
UBICACIÓN DE LA TOMA DE ELECTRICIDAD
EMPLACEMENT DE LA PRISE DE COURANT
WM16W-Q*1C
PAGE 3 97043C(Rev. B - 4/98)
PUSH BUTTON VALVE ADJUSTMENT
FIG. 3
FIG. 4
CORRECT STREAM HEIGHT
FIG. 5
STREAM HEIGHT
ADJUSTMENT SCREW
17
2325
24
22,26,27
1
ADJUST THIS SCREW TO ELIMINATE VALVE
LEVER "FREE PLAY" OR CONTINUOUS FLOW
FROM BUBBLER
97043C(Rev. B - 4/98)
WM16W-Q*1C
PAGE 4
ITEMIZED PARTS LIST
ITEM NO. PART NO.
DESCRIPTION
51544C
102639931640
160270508640
171454842590
70568C
66327C
35839C
35762C
31027C
194243901550
35766C
45688C
601418151550
101543431640
101507531550
75494C
55860C
40136C
66202C
66332C
31517C
15005C
26860C
26861C
26862C
50986C
61314C
55996C
45670C
55885C
55913C
See Color Table
See Color Table
See Color Table
Bubbler
Drain Plug
Strainer Plate
Basin
Elbow 5/16 O.D. Tube x 3/8 NPT
Evaporator
Cold Control
Compressor Serv. Pak
Overload/Relay Assy
Electrical Shield
Relay Cover
Precooler
Condenser
Cap Push Button
Push Button Stem
Check Valve
Regulator Bracket
Water Temperature Valve
Drier
Heat Exchanger
Power Cord
Regulator Retaining Nut
Regulator Lever
Pivot Bracket
Regulator Retaining Bracket
Regulator Holder
Regulator
Strainer
Vacuum Break
Nut 1-1/4 Slip Joint
Adaptor - Drain
Side Panel - Right
Side Panel - Left
Front Panel (Not Shown)
1
2
3
4
5
6
7*
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE
WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the above water coolers or
orders for repair parts MUST include Model No. and Serial No. of cooler, name
and part number of replacement part.
2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
PRINTED IN U.S.A.
FIG. 6
CONDENSER WATER VALVE ADJUSTMENT
The condenser water valve is factory preset for a condenser water outlet temperature of 95° to 105° F.
If actual temperature varies greatly from this, readjust water flow rate at the valve using the following procedures.
1. START UP COMPRESSOR
This can be accomplished by depressing the cooler push button (See Fig. 1 - Item 3). Keep water
running during the entire readjustment procedure.
2. ADJUSTMENT CONDENSER WATER VALVE
Adjust valve by rotating adjustment stem. Rotating stem clockwise will increase water flow.
Counterclockwise rotation will decrease water flow. Increasing water flow will result in a lower
condenser outlet temperature, while decreasing water flow will result in a higher outlet temperature.
Proper adjustment is attained when condenser outlet temperature is 95° to 105° F.
WIRING DIAGRAM
This drawing is merely for illustrating the
components of the electrical system.
COLOR
ITEM 33
Platinum (PV)
Slate (SV)
Stainless Steel (SS)
401432248410
401432248440
401432242830
ITEM 34
401483948410
401483948440
401483942830
ITEM 32
401484048410
401484048440
401484042830
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4