Halsey Taylor SCWTWC.J Le manuel du propriétaire

Taper
Le manuel du propriétaire
SCWT14WQ*1J
98339C (11/06)PAGE 1
HALSEY TAYLOR OWNERS MANUAL
USES HFC-134A REFRIGERANT
FIG. 1
SEE FIG. 4
25
17
33
11
18
16
12,13,14, & 15
19
21
26
27
32
3, 4
7
2, 30 - SEE FIG. 5
5, 6
28, 29, 36
35
22
34
31
SCWT14WQ*1J
PAGE 298339C (11/06)
FIG. 2
E = INSURE PROPER VENTILATION BY MAINTAINING 4" (102mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 4" (102mm) (MÍN.) DE HOLGURA ENTRE LA
REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 4" (102mm) (MIN.) ENTRE LES ÉVENTS DE L’ENCEINTE ET LE
MUR.
F = POWER CORD 4' (1219mm) LONG
CABLE ELÉCTRICO DE 4' (1219mm) PIE, DE LARGO
CORDON D’ALIMENTATION 4' (1219mm)
G = WALL SCREW HOLES
AGUJEROS DE TORNILLOS DE PARED
TROUS DE VIS DU MUR
H = 2 X 4 BLOCKING
BLOQUEO DE 2 X 4
BLOC 2 X 4
FINISHED FLOOR
PISO ACABADO
PLANCHER FINI
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB OUT 1-1/2 IN. (38mm)
FROM WALL SHUT OFF BY OTHERS
SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIÁM. EXT. A 1-1/2"
(38 mm) FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS.
EMPLACEMENT RECOMMANDÉ D'ALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 mm) D.E.
CONNECTANT UNE TUYAUTERIE DE 1-1/2 PO. (38 mm) DEPUIS LE ROBINET D'ARRÊT FOURNI PAR D'AUTRES.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼” DE DIÁMETRO.
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE D’EAU.
C = 1-1/4 TRAP NOT FURNISHED
PURGADOR DE 1¼ NO PROPORCIONADO
SIPHON 1-1/4 NON FOURNI
D = ELECTRICAL OUTLET LOCATION
UBICACIÓN DE LA TOMA DE ELECTRICIDAD
EMPLACEMENT DE LA PRISE DE COURANT
SCWT14WQ*1J
98339C (11/06)PAGE 3
PUSH BUTTON VALVE ADJUSTMENT
FIG. 3
ADJUST THIS SCREW TO ELIMINATE VALVE
LEVER "FREE PLAY" OR CONTINUOUS FLOW
FROM BUBBLER
STREAM HEIGHT
ADJUSTMENT SCREW
FIG. 4
2
23
8
9
10
1,20,24
CORRECT STREAM HEIGHT
FIG. 5
SCWT14WQ*1J
PAGE 498339C (11/06)
ITEM NO. PART NO.
DESCRIPTION
15005C
51544C
101507531550
101453431640
102639931640
160270508640
28346C
26860C
26861C
26862C
31513C
36250C
36255C
36189C
36254C
36219C
45696C
66767C
40136C
50986C
45394C
66506C
55880C
61314C
66203C
75494C
55996C
55913C
75588C
56159C
70682C
See Color Table
See Color Table
56092C
70683C
75589C
See Color Table
Nut-Regulator Retaining
Bubbler
Push Button Stem
Cap Push Button
Drain Plug
Strainer Plate
Basin
Regulator Lever
Pivot Bracket
Regulator Retaining Bracket
Cold Control
Compressor Service Pak
Overload
Relay Cover
Relay
Power Cord
Tailpipe Assy
Heat Exchanger
Water Temperature Valve
Regulator Holder
Condenser Assy
Evaporator
Regulator Mounting Bracket
Regulator
Drier
Check Valve
Strainer
Adaptor-Drain W/O Holes
Nut - Slip Joint 1-1/4
Nipple - Bubbler
Tee - 1/4
Side Panel - Right
Side Panel - Left
Poly Tubing (Cut To Length)
Union - 1/4
Gasket
Front Panel
Platinum (PV)
Almond (AV)
Slate (SV)
Stnlss Stl (SS)
401536248410
26912C
401536248440
401536242830
401536348410
26908C
401536348440
401536342830
401507448410
26904C
401507448440
401507442830
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
PRINTED IN U.S.A.
RIGHT PANEL FRONT PANELCOLOR LEFT PANEL
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE
WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the above water coolers or
orders for repair parts MUST include Model No. and Serial No. of cooler,
name and part number of replacement part.
ITEMIZED PARTS LIST
1
2
3
4
5
6
7
8
9
10
11
12*
13
14
15
16
17**
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
NS
FIG. 6
CONDENSER WATER VALVE ADJUSTMENT
The condenser water valve is factory preset for a condenser water outlet temperature of 95° to 105° F.
If actual temperature varies greatly from this, readjust water flow rate at the valve using the following procedures.
1. START UP COMPRESSOR
This can be accomplished by depressing the cooler push button (See Fig. 1 - Item 4). Keep water
running during the entire readjustment procedure.
2. ADJUSTMENT CONDENSER WATER VALVE
Adjust valve by rotating adjustment stem. Rotating stem clockwise will decrease water flow.
Counterclockwise rotation will increase water flow. Increasing water flow will result in a lower
condenser outlet temperature, while decreasing water flow will result in a higher outlet temperature.
Proper adjustment is attained when condenser outlet temperature is 95° to 105° F.
WIRING DIAGRAM
This drawing is merely for illustrating the
components of the electrical system.
**Includes Items 28, 29 & 36