Halsey Taylor WM14W.P Le manuel du propriétaire

Taper
Le manuel du propriétaire
WM14WQ*1P
PAGE 1 98341C (11/06)
HALSEY TAYLOR OWNERS MANUAL
USES HFC-134A REFRIGERANT
FIG. 1
2, 3
4
SEE FIG. 5
1, 32
14,15
8,9,10,11
19
6
20
16
34
13
29
12
7
21
28
35
5,18
SEE
FIG. 6
SEE
FIG. 4
33
30, 31, 39
39
38
36
98341C (11/06)
WM14WQ*1P
PAGE 2
FIG. 2
E = INSURE PROPER VENTILATION BY MAINTAINING 4" (102mm) MIN. CLEARANCE FROM CABINET LOUVERS TO WALL.
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 4" (102mm) MÍN. DE HOLGURA ENTRE LA
REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 4" (102mm) MIN. ENTRE LES ÉVENTS DE L’ENCEINTE ET LE MUR.
F = POWER CORD 4' (1219mm) LONG
CABLE ELÉCTRICO DE 4' (1219mm), DE LARGO
CORDON D’ALIMENTATION 4' (1219mm)
G = 1/4" (6mm) SCREW HOLES IN MOUNTING PLATE
AGUJEROS DE TORNILLO 1/4" (6mm) EN LA PLACA DE MONTAJE
TROUS DE VIS 1/4" (6mm) DANS LA PLAQUE DE MONTAGE
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB OUT 1-1/2 IN.
(38mm) FROM WALL SHUT OFF BY OTHERS
SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIÁM.
EXT. A 1-1/2" (38 mm) FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS.
EMPLACEMENT RECOMMANDÉ D'ALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5
mm) D.E. CONNECTANT UNE TUYAUTERIE DE 1-1/2 PO. (38 mm) DEPUIS LE ROBINET D'ARRÊT FOURNI PAR
D'AUTRES.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼” DE DIÁMETRO.
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE D’EAU.
C = 1-1/4 TRAP NOT FURNISHED
PURGADOR DE 1¼ NO PROPORCIONADO
SIPHON 1-1/4 NON FOURNI
D = ELECTRICAL OUTLET LOCATION
UBICACIÓN DE LA TOMA DE ELECTRICIDAD
EMPLACEMENT DE LA PRISE DE COURANT
WM14WQ*1P
PAGE 3 98341C (11/06)
PUSH BUTTON VALVE ADJUSTMENT
FIG. 3
FIG. 4
CORRECT STREAM HEIGHT
FIG. 5
STREAM HEIGHT
ADJUSTMENT SCREW
17
2325
24
22,26,27
1
ADJUST THIS SCREW TO ELIMINATE VALVE
LEVER "FREE PLAY" OR CONTINUOUS FLOW
FROM BUBBLER
98341C (11/06)
WM14WQ*1P
PAGE 4
ITEMIZED PARTS LIST
ITEM NO.
PART NO.
DESCRIPTION
51544C
102639931640
160270508640
28340C
75561C
66506C
31513C
36250C
36254C
36255C
36189C
45696C
601418151550
101453431640
101507531550
75494C
55860C
40136C
66203C
66767C
36208C
15005C
26860C
26861C
26862C
50986C
61314C
55996C
45670C
75588C
55913C
56159C
70682C
See Color Table
See Color Table
56092C
70683C
See Color Table
75589C
400660943730
Bubbler
Drain Plug
Strainer Plate
Basin
Fitting-Elbow 3/8 x 3/8 NPT x 90
Evaporator
Cold Control
Compressor Serv. Pak
Overload
Relay
Relay Cover
Tailpipe Assy
Condenser
Cap Push Button
Push Button Stem
Check Valve
Regulator Bracket
Water Temperature Valve
Drier
Heat Exchanger
Power Cord
Regulator Retaining Nut
Regulator Lever
Pivot Bracket
Regulator Retaining Bracket
Regulator Holder
Regulator
Strainer
Vacuum Break
Nut - Slip Joint 1-1/4
Adaptor - Drain
Nipple - Bubbler
Tee - 1/4
Side Panel - Right
Side Panel - Left
Poly Tubing (Cut To Length)
Union - 1/4
Front Panel
Gasket
Hanger Bracket
1
2
3
4
5
6
7
8*
9
10
11
12**
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
-
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE
WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the above water coolers or
orders for repair parts MUST include Model No. and Serial No. of cooler, name
and part number of replacement part.
2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
PRINTED IN U.S.A.
CONDENSER WATER VALVE ADJUSTMENT
The condenser water valve is factory preset for a condenser water
outlet temperature of 95° to 105° F.
If actual temperature varies greatly from this, readjust water flow rate
at the valve using the following procedures.
1. START UP COMPRESSOR
This can be accomplished by depressing the cooler push button
(See Fig. 1 - Item 14). Keep water running during the entire
readjustment procedure.
2. ADJUSTMENT CONDENSER WATER VALVE
Adjust valve by rotating adjustment stem. Rotating stem clockwise will
decrease water flow. Counterclockwise rotation will increase water
flow. Increasing water flow will result in a lower condenser outlet
temperature, while decreasing water flow will result in a higher outlet
temperature. Proper adjustment is attained when condenser outlet
temperature is 95° to 105° F.
WIRING DIAGRAM
This drawing is merely for illustrating the
components of the electrical system.
FIG. 6
COLOR
ITEM 35
Platinum (PV)
Stainless Steel (SS)
401432248410
401432242830
ITEM 38
401483948410
401483942830
ITEM 34
401484048410
401484042830
**Includes items 30, 31 & 39
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
FAN
10
12
M
13
C
S
2
GND
COLD CONTROL
(WATER)
WHT
BLK
11
3
1
14
OVERLOAD
COMPRESSOR
RELAY
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Halsey Taylor WM14W.P Le manuel du propriétaire

Taper
Le manuel du propriétaire