Halsey Taylor SCWTWQ.K Le manuel du propriétaire

Taper
Le manuel du propriétaire
SCWT14WQ*1K
98702C (Rev. B - 5/11)PAGE 1
HALSEY TAYLOR OWNERS MANUAL
USES HFC-134A REFRIGERANT
FIG. 1
SEE FIG.4
25
17
33
11
18
16
12,13,14,
34, 35
19
21
26
27
32
3, 4
7
2, 30 - SEE FIG.5
5, 6
15, 28, 29
37
22
36
31
SCWT14WQ*1K
PAGE 298702C (Rev. B - 5/11)
FIG. 2
E = INSURE PROPER VENTILATION BY MAINTAINING 4" (102mm) (MIN.) CLEARANCE FROM CABINET LOUVERS
TO WALL.
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 4" (102mm) (MÍN.) DE HOLGURA
ENTRE LA REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 4" (102mm) (MIN.) ENTRE LES ÉVENTS DE
L’ENCEINTE ET LE MUR.
F = POWER CORD 4' (1219mm) LONG
CABLE ELÉCTRICO DE 4' (1219mm) PIE, DE LARGO
CORDON D’ALIMENTATION 4' (1219mm)
G = WALL SCREW HOLES
AGUJEROS DE TORNILLOS DE PARED
TROUS DE VIS DU MUR
H = 2 X 4 BLOCKING
BLOQUEO DE 2 X 4
BLOC 2 X 4
FINISHED FLOOR
PISO ACABADO
PLANCHER FINI
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB OUT 1-1/2 IN. (38mm)
FROM WALL SHUT OFF BY OTHERS
SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIÁM. EXT. A 1-1/2"
(38 mm) FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS.
EMPLACEMENT RECOMMANDÉ D'ALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 mm) D.E.
CONNECTANT UNE TUYAUTERIE DE 1-1/2 PO. (38 mm) DEPUIS LE ROBINET D'ARRÊT FOURNI PAR D'AUTRES.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼” DE DIÁMETRO.
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE D’EAU.
C = 1-1/4 TRAP NOT FURNISHED
PURGADOR DE 1¼ NO PROPORCIONADO
SIPHON 1-1/4 NON FOURNI
D = ELECTRICAL OUTLET LOCATION
UBICACIÓN DE LA TOMA DE ELECTRICIDAD
EMPLACEMENT DE LA PRISE DE COURANT
SCWT14WQ*1K
98702C (Rev. B - 5/11)PAGE 3
PUSH BUTTON VALVE ADJUSTMENT
FIG. 3
ADJUST THIS SCREW TO ELIMINATE VALVE
LEVER "FREE PLAY" OR CONTINUOUS FLOW
FROM BUBBLER
STREAM HEIGHT
ADJUSTMENT SCREW
FIG. 4
2
23
8
9
10
1,20,24
CORRECT STREAM HEIGHT
FIG. 5
WIRING DIAGRAM
This drawing is merely for illustrating the
components of the electrical system.
SCWT14WQ*1K
PAGE 498702C (Rev. B - 5/11)
ITEM NO. PART NO.
DESCRIPTION
15005C
51544C
101507531550
101453431640
102639931640
160270508640
28346C
26860C
26861C
26862C
35839C
36312C
35840C
35768C
75589C
192668451550
45696C
66581C
75561C
50986C
66798C
66811C
55880C
61314C
66203C
75494C
55996C
55913C
75588C
56159C
70682C
See Color Table
See Color Table
35843C
35844C
56092C
70683C
75583C
See Color Table
Nut-Regulator Retaining
Bubbler
Push Button Stem
Cap Push Button
Drain Plug
Strainer Plate
Basin
Regulator Lever
Pivot Bracket
Regulator Retaining Bracket
Cold Control
Compressor Service Pak
Overload
Relay Cover
Gasket
Power Cord
Tailpipe Assy
Heat Exchanger
Elbow - 3/8"
Regulator Holder
Condenser Assy
Evaporator
Regulator Mounting Bracket
Regulator
Drier
Check Valve
Strainer
Adaptor-Drain W/O Holes
Nut - Slip Joint 1-1/4
Nipple - Bubbler
Tee - 1/4
Side Panel - Right
Side Panel - Left
Relay
Capacitor
Poly Tubing (Cut To Length)
Union - 1/4
Elbow - 5/16" x 1/4"
Front Panel
401536248410
26912C
401536248440
401536242830
401536348410
26908C
401536348440
401536342830
401507448410
26904C
401507448440
401507442830
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
PRINTED IN U.S.A.
RIGHT PANEL FRONT PANELLEFT PANEL
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE
WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the above water coolers or
orders for repair parts MUST include Model No. and Serial No. of cooler,
name and part number of replacement part.
ITEMIZED PARTS LIST
1
2
3
4
5
6
7
8
9
10
11
*12
13
14
15
16
**17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
NS
NS
FIG. 6
CONDENSER WATER VALVE ADJUSTMENT
The condenser water valve is factory preset for a
condenser water outlet temperature of 95° to 105° F.
If actual temperature varies greatly from this, readjust water
flow rate at the valve using the following procedures.
1. START UP COMPRESSOR
This can be accomplished by depressing the cooler
push button (See Fig. 1 - Item 4). Keep water
running during the entire readjustment procedure.
2. ADJUSTMENT CONDENSER WATER VALVE
Adjust valve by rotating adjustment stem. Rotating stem
clockwise will decrease water flow.
Counterclockwise rotation will increase water flow.
Increasing water flow will result in a lower
condenser outlet temperature, while decreasing water
flow will result in a higher outlet temperature.
Proper adjustment is attained when condenser outlet
temperature is 95° to 105° F.
**Includes Items 15, 28 & 29
Platinum (PV)
Almond (AV)
Slate (SV)
Stnlss Stl (SS)
COLOR