USER MANUAL ............................................................................. 0
Line Interactive..................................................................................... 0
1000VA/1400VA/2000VA .................................................................... 0
Uninterruptible Power System ..................................................... 0
1000 .................................................................................................... 14
1400 .................................................................................................... 14
2000 .................................................................................................... 14
INPUT ........................................................................................ 14
OUTPUT .................................................................................... 14
BATTERY .................................................................................. 14
INDICATOR............................................................................... 14
PROTECTION ........................................................................... 14
PHYSICAL................................................................................. 14
ENVIRONMENT ....................................................................... 14
INTERFACE .............................................................................. 14
MANUEL D’UTILISATION....................................................... 16
Line-interactive................................................................................... 16
1000 VA/1400 VA/2000 VA ............................................................... 16
Système d’alimentation sans coupure ........................................ 16
1000 ................................................................................................... 28
1400 ................................................................................................... 28
2000 ................................................................................................... 28
ENTRÉE ...................................................................................... 28
SORTIE....................................................................................... 28
BATTERIE................................................................................... 28
INDICATEUR ............................................................................. 28
PROTECTION ............................................................................ 28
PHYSIQUE ................................................................................. 28
2
ENVIRONNEMENT .................................................................... 28
INTERFACE ................................................................................ 28
MANUAL DEL USUARIO ......................................................... 30
Línea Interactiva ................................................................................. 30
1000 VA/1400 VA/2000 VA ............................................................... 30
Sistema de alimentación ininterrumpida .................................... 30
1000 .................................................................................................... 42
1400 .................................................................................................... 42
2000 .................................................................................................... 42
ENTRADA ................................................................................. 42
SALIDA ..................................................................................... 42
BATERÍA ................................................................................... 42
INDICADOR.............................................................................. 42
PROTECCIÓN ........................................................................... 42
DATOS FÍSICOS ....................................................................... 42
ENTORNO ................................................................................. 42
INTERFAZ ................................................................................. 42
3
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS This manual
contains important instructions for Line
Interactive 1000VA /1400VA /2000VA that
shall be followed during installation and
maintenance for the UPS and batteries.
Safety Cautions & Warnings!
This UPS utilizes voltages that may be hazardous. Do not attempt to
disassemble the unit. The unit contains no user serviceable parts. Only
factory service personnel may perform repairs.
Internal battery voltage is 12Vdc for 1000VA and 24Vdc for 1400 and
2000VA. Sealed, lead-acid, 6 cells battery.
Connection to any other type of receptacle other than a two-pole,
three-wire grounding receptacle may result in shock hazard as well as
violate local electrical codes.
In the event of an emergency, turn the power switch to the “off
position and disconnect the power cord form the AC power supply to
properly disable the UPS
Do not allow any liquids or any foreign object to enter the UPS. Do not
place beverages or any other liquid-containing vessels on or near the
unit.
This unit intended for installation in a controlled environment
(temperature controlled, indoor area free of conductive contaminants).
Avoid installing the UPS in locations where there is standing or running
water, or excessive humidity.
Do not plug the UPS input into its own output.
Do not attach a power strip or surge suppressor to the UPS.
Do not attach non-computer-related items, such as medical equipment,
life-support equipment, microwave ovens, or vacuum cleaners to UPS
Regularly remove dust or dirt with a dry, soft cloth from the vents of the
unit to avoid the unit from overheating.
To reduce the risk of overheating the UPS, do not cover the UPS’
cooling vents. Avoid exposing the unit to direct sunlight or installing the
unit near heat emitting appliances such as space heaters or furnaces.
4
Unplug the UPS prior to cleaning and do not use liquid or spray
detergent.
A battery can present a risk of electrical shock and high short circuit
current. BATTERY IS NOT USER REPLACEABLE.
There are no user-serviceable parts inside the UPS.
During the installation of this equipment it should be assured that the
sum of the leakage currents of the UPS and the connected loads does
not exceed 3.5mA.
The main socket outlet that supplies the UPS shall be installed near the
UPS and shall be easily accessible.
CAUTION - To reduce the risk of fire, connect only to a circuit provided
with 20 amperes maximum branch circuit overcurrent protection in
accordance with the National Electrical Code, ANSI/NFPA 70.
5
System Description
1. Front Panel
1. LCD Back-Light
2. Power “ON/OFF” Switch
2.
Back Panel
1. USB Port
2. Cooling Fan
3. Modem/Phone Line Surge Protection
4. Circuit Breaker
5. AC Output
6. AC Input
1000VA 1400-2000VA
6
Installation and Operation
Installing the UPS is as easy as following the steps shown below.
Be aware that the Power Switch must be kept in the “ONposition,
otherwise, the UPS will be disabled and your equipment will not be
protected during a power failure.
1. Inspection
Remove the UPS from its packaging and inspect it for damage that may
have occurred during shipping. If any damage is discovered, repack the
unit and return it to the place of purchase.
2. Placement
Install the UPS unit in any protected environment that provides adequate
airflow around the unit, and is free from excessive dust, corrosive fumes
and conductive contaminants. Do not operate your UPS in an environment
where the ambient temperature is above 40°C or 104°F, or where
humidity is high. Place the UPS unit away from monitor at least 20cm to
avoid interference.
3. Charging
This unit is shipped from the factory with its internal battery fully charged.
However, some energy may be lost during shipping so the battery should
be recharged before use. Plug the unit into an appropriate power supply
and allow the UPS to charge fully by leaving it plugged in for 10 hours.
7
4. Computer Connection
Connect one computer-related device into each of the power receptacles
supplied on the back of the UPS (maximum of three devices).
5. Modem/Phone line Connection
Plug incoming internet line into the “In” socket located at the back of the
UPS. Use one more Internet line cable and plug one end of the Internet
line cable to the “Out” socket located at the back of the UPS. Plug the
other end to the modem input socket as shown immediately below.
8
6. Serial Cable Connection
To allow for unattended system shutdown for your operating system,
connect the serial cable as per diagram below.
7. Turn On/Off
To turn on the UPS unit, press the power switch lightly. To turn off the
UPS unit, press the power switch again (When Switch ONThe LED is
illuminated.).
8. LCD Display Specification
The LED should always turn on when UPS is properly functioning,
including when the UPS is in the "off charging mode" and "fault mode."
When the LCD functions, it will display the following information (see page
9).
9
1) When in normal mode, LED panel
1
will display as shown below.
Low Voltage Version
2) When in AVR mode, LED panel will display as shown below. And the
icon will flicker every 1 second.
Low Voltage Version
3) When in battery mode, LED panel will display as shown below. And the
icon will flicker every 1 second.
Low Voltage Version
Note: If I/P-V<40Vinput voltage will display “000”
4) When in off charging mode, LED panel will display as shown below.
Low Voltage Version
1
10
Note: the output voltage always is displayed as “000 in off charging mode.
5) When in fault mode, LED panel will display as shown below. “FAULT”
character and the corresponding code for the reason of fault only.
Note: the fault code will be showed in fault mode.
6) Load level definition:
Load LEVEL
Load Bar Indication
0%~25%
25%~50%
50%~75%
75%~100%
7) For 12V (1000VA) battery capacity definition:
Battery Mode:
Battery LEVEL
Battery Bar Indication
Battery voltage<11V
11V≤Battery voltage<11.5V
11.5V≤Battery
voltage<12.5V
Battery voltage≥12.5V
11
Line Mode:
Battery LEVEL
Battery Bar Indication
Battery voltage<12.7V
12.7V≤Battery
voltage<13.2V
13.2Battery
voltage<13.5V
Battery voltage≥13.5V
For 24V (1400VA/2000VA) battery capacity definition:
Battery Mode:
Battery LEVEL
Battery Bar Indication
Battery voltage<22.0V
22V≤Battery voltage<23.0V
23V≤Battery voltage<25V
Battery voltage≥25V
Line Mode:
Battery LEVEL
Battery Bar Indication
Battery voltage<25.4V
25.4VBattery
voltage<26.4V
26.4V≤Battery
voltage<27.0V
Battery voltage≥27.0V
8) When experiencing over load, the icon will flicker every 1
second.
12
9) When battery low, the icon will flicker every 1 second.
Software Installation WinPower Monitoring Software
WinPower is a UPS monitoring software, which provides user-friendly
interface to monitor and control your UPS. This unique software safely
provides auto shutdown for multi-computer systems when there is a power
failure. With this software, users can monitor and control any UPS on the
same LAN no matter how far from the UPS
Installation procedure:
1. Go to the website:
http://www.ups-software-download.com/index.htm
2. Choose the operating system you need and follow the instruction
described on the website to download the software.
3. When downloading all required files from the internet, enter the serial
No: 511C1-01220-0100-478DF2A to install the software.
When your computer restarts, the WinPower software will appear as a
green plug icon located in the system tray, near the clock icon.
13
Troubleshooting
Refer to the table below for solving minor installation and operation issues. If
any abnormal situations occur that are not listed in table below, please call
technical support at 1-888-222-5487 for further assistance.
Symptom
Possible Cause
Remedy
No LED display on
the front panel
Missing battery
Charge battery up to 12 hours
Battery defect
Call technical support for
service
The power cord is
disconnected
Ensure that power cord is
plugged in to outlet
Alarm buzzer
beeps
continuously
Overload of the UPS
Call technical support for
service
During a loss of
power, the backup
time is reduced.
Overload of the UPS
Call technical support for
service
Battery voltage is too low
Charge battery up to 12 hours
Improper operation of
battery
Call technical support for
service
Communication
lost between UPS
and computer
Software is not installed
properly
Check the software settings
Cable is not properly
connected
Check that USB cable is firmly
connected to the computer
* The internal batteries are not user-replaceable. Call technical support at
1-888-222-5487 for servicing information.
14
Specification
MODEL
1400
2000
CAPACITY
VA/W
1400VA/840W
2000VA/1200W
INPUT
Voltage
120VAC
Voltage Range
+/- 15% line input
OUTPUT
Voltage
120VAC
Voltage Regulation
(Battery Mode)
+/- 10%
Frequency
50Hz or 60Hz
Frequency Regulation
(Battery Mode)
+/-1 Hz
Output Waveform
Modified Sine Wave
BATTERY
Battery Type
12V9Ah x 2pcs
Back up Time (at 2 PC
load with a 15 monitor)
25 minutes
Recharge Time
6 Hours to 90% after complete
discharge
TRANSFER
TIME
4-8ms (Typical)
INDICATOR
AC Mode/ Backup
Mode/ Fault
Introduce as Front Panel - LCD
AUDIBLE
ALARM
Backup Mode
Sounding every 10 seconds
Battery Low
Sounding every 1 second
Overload
Sounding every 0.5 seconds
Fault
Continuous sounding
PROTECTION
Full Protection
Overcharge and Overload Protection
PHYSICAL
Dimension (D x H x W)
15.9 x 8.1 x 5.7in
WEIGHT
Net Weight
21.4lbs
26.5lbs
ENVIRONMENT
Operating Environment
32-104ºF, 0-90 % Relative Humidity (non-condensing)
Noise Level
Less than 45dB
INTERFACE
USB
Windows 98/ME/2000/2008 Server/2011 SBS/
XP/Vista/ 7 (32 & 64 Bit Version)
15
WWW.ULTRAPRODUCTS.COM
8300 West Flagler Street, #121-106
Miami, FL 33144
Technical Support: 1-888-222-5487
© Streak Products Inc. XFINITY® is a product of ULTR.
XFINITY® and ULTR are registered trademarks of Streak Products Inc.
All other trademarks listed are the property of their respective owners.
Streak Products Inc. is not responsible for any typographical or photographic
errors.
16
MANUEL
D’UTILISATION
Line-interactive
1000 VA/1400 VA/2000 VA
.
L’image peut varier en fonction du modèle.
Système d’alimentation sans coupure
17
CONSIGNES DE SÉCURI
IMPORTANTES
CONSERVEZ CES CONSIGNES Ce manuel
contient des consignes importantes pour le
Line-interactive 1000 VA/1400 VA/2000 VA
qui doivent être suivies lors de linstallation
et de lentretien du système dalimentation
sans coupure et des batteries.
curité Pcautions et mises en garde!
Ce système d’alimentation sans coupure utilise des tensions qui
peuvent être dangereuses. N’essayez pas de sassembler l’appareil.
L’appareil ne contient aucune pièce parable par l’utilisateur. Seul le
personnel d’entretien à l’usine peut effectuer des réparations.
La tension interne de la batterie est de 12 V cc pour 1000 VA et de 24 V
cc pour 1400 et 2000 VA. Batterie au plomb-acide scellée à 6 cellules.
Le branchement à tout autre type de prise de courant murale autre
qu’une prise trifilaire, bipolaire avec prise de terre peut entraîner des
risques d’électrocution ainsi que violer les codes locaux d’électricité.
En cas d’urgence, mettez l’interrupteur d’alimentation en position
« off » (« arrêt »), puis branchez le cordon d’alimentation du bloc
d’alimentation secteur pour sactiver correctement le système
d’alimentation sans coupure.
Ne laissez aucun liquide ni tout autre objet étranger nétrer dans le
système d’alimentation sans coupure. Ne placez pas de boissons ni tout
autre récipient contenant du liquide sur lappareil ou près de celui-ci.
Cet appareil est destiné à être installé dans un environnement contrôlé
(température contrôlée, espace intérieur exempt de contaminants
conducteurs). Évitez d’installer le système d’alimentation sans coupure
dans des endroits où il y a de leau stagnante ou courante, ou une
humidi excessive.
Ne branchez pas l’entrée du système d’alimentation sans coupure dans
sa propre sortie.
18
Ne fixez pas une barre multiprise ou un parasurtenseur au système
d’alimentation sans coupure.
Ne fixez pas d’éléments non liés à l’informatique, tels que de
léquipement médical, du mariel d’assistance vitale, des fours à
micro-ondes ou des aspirateurs au système d’alimentation sans
coupure.
Enlevez régulièrement la poussière ou la saleté à laide d’un chiffon
doux et sec des évents de lappareil pour lui éviter de surchauffer.
Pour duire le risque de surchauffe du système d’alimentation sans
coupure, ne couvrez pas les évents de refroidissement du système.
Évitez d’exposer l’appareil à la lumière directe du soleil ou d’installer
lappareil à proximi d’appareils émettant de la chaleur tels que les
appareils de chauffage autonomes ou les fournaises.
Débranchez le système d’alimentation sans coupure avant de le
nettoyer et n’utilisez pas de détergent liquide ou en aérosol.
Une batterie peut présenter un risque de charge électrique et un
courant de court-circuit élevé. LA BATTERIE N’EST PAS REMPLAÇABLE
PAR L’UTILISATEUR.
Il n’y a aucune pièce réparable par l’utilisateur à l’intérieur du système
d’alimentation sans coupure.
Lors de l’installation de cet équipement, on doit s’assurer que la somme
des courants de fuite du système d’alimentation sans coupure et des
charges connectées ne dépasse pas 3,5 mA.
La prise de courant secteur qui fournit le système d’alimentation sans
coupure devra être installée près du sysme et être facilement
accessible.
PRUDENCE - À réduire l'aa de tirer connect unique à une circuit
suppléer à 20 ampères maximum succursale circuit overcurrent
protection dans accord à les Ressortissant Électrique Code ANSI/NFPA
70.
19
Description du sysme
1. Panneau avant
1. ACL avec rétroéclairage
2. Interrupteur « On/Off » (Marche/Arrêt)
3.
Panneau arrière
1. Port USB
2. Ventilateur
3. Protection contre les surtensions de
la ligne téléphonique/du modem
4. Disjoncteur
5. Sortie CA
6. Entrée CA
1000 VA 1400 - 2000 VA
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Comcast 1400VA Manuel utilisateur

Catégorie
Alimentations sans interruption (UPS)
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues