Breckwell BH2818i Manuel utilisateur

Catégorie
Cheminées
Taper
Manuel utilisateur

Ce manuel convient également à

Model AH2818i
853307-5102H
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Report # F18-427
Please read this manual BEFORE installing and
operating this replace.
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon monoxide, which
is known to the State of California to cause cancer, birth defects and/or other
reproductive harm. For more information, go to www.P65warnings.ca.gov
Ce produit peut vous exposer à des produits chimiques, y compris le
monoxyde de carbone, qui est connu dans l'État de Californie pour causer
le cancer, des malformations congénitales et / ou d'autres problèmes de
reproduction. Pour plus d'informations, visitez www.P65warnings.ca.gov
- Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re department.
- Installation and service must be performed by a qualied installer, service agency or the gas supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
109 East 17th Street, Suite 5478 • Cheyenne, WY 82001 •
Phone: (833) 222-3241 • Web: www.acadiahearth.com
2
This appliance may be installed in an after-market, permanently located, manufactured home (USA only) or mobile home,
where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases, unless a certied kit is used.
After-market: Completion of sale, not for purpose of resale, from the manufacturer.
Laboratory:
PFS-TECO Laboratories, Clackamas, Oregon
Standards:
ANSI Z21.88-2017 /CSA 2.33-2017, Vented Gas Fireplace Heaters
CSA 2.17-2017, Gas-Fired Appliances for Use at High Altitudes
CSA P.4.1-2015, Testing Method for Measuring Annual Fireplace Efciency
This installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.
852502B










!
www.ncertied.org
We recommend that our gas
hearth products be installed
and serviced by profes-
sionals who are certied in
the U.S. by the National
Fireplace Institute® (NFI) as
NFI Gas Specialists.
CERTIFICATIONS
3
APPLIANCE DIMENSIONS .............................................. 5
PART ASSEMBLY OVERVIEW .......................................... 6
SAFETY LABEL .................................................................. 7
REQUIREMENTS FOR THE COMMONWEALTH OF
MASSACHUSETTS ............................................................ 8
Installation of Carbon Monoxide Detectors .........................8
Approved Carbon Monoxide Detectors .............................. 8
Signage ...................................................................................8
Inspection................................................................................8
Exemptions ..............................................................................8
Manufacturer Requirements ..................................................8
Gas Equipment Venting System NOT Provided ...................8
BEFORE YOU START ........................................................ 9
PRODUCT FEATURES ..................................................... 10
Product Specications ...........................................................10
Controls ...................................................................................10
High Elevations .......................................................................11
PART OVERVIEW ............................................................ 11
EXISTING FIREPLACE REQUIREMENTS ............................ 12
Appliance Placement Considerations ................................. 12
Existing Fireplace Specications ...........................................12
Existing Fireplace Opening Minimum Requirements .......... 12
Chimney Specications .........................................................12
Existing chimney height: ........................................................13
Determine Length of Existing Chimney ................................13
TERMINATION LOCATION .............................................. 13
Vent Termination Clearances ...............................................13
Minimum Termination Clearances .......................................14
INSTALLATION PREPARATION ........................................ 15
Inspect and Clean Existing Chimney ...................................15
Flue Damper............................................................................15
Gas Line ...................................................................................15
Electrical Wiring ......................................................................15
Fireplace Conversion .............................................................15
INSTALLATION ................................................................. 16
Co-Linear Vent System ..........................................................16
Remove Air Duct .....................................................................16
Run Vent System ..................................................................... 17
Connect Vent Pipe to Air Duct .............................................. 17
Place and Secure Appliance ................................................18
GAS LINE CONNECTION ............................................... 19
Gas Conversion (sold separately) ........................................ 19
Gas Line Installation ...............................................................19
FACING AND FINISHING ................................................ 19
Clearances to Combustibles .................................................19
LOG, LINER, SAFETY BARRIERS, & SURROUND
INSTALLATION ................................................................. 20
GAS FIREPLACE INSERT SETUP ....................................... 20
Glass Frame Assembly ...........................................................20
Remove Glass Assembly .......................................................20
Install Glass Assembly ............................................................21
CONTROL BOARD ......................................................... 22
ELECTRICAL INFORMATION........................................... 22
Electrical Grounding Instructions .......................................... 22
Wiring Requirements ..............................................................22
REPLACEMENT PARTS AND SERVICE ............................ 24
Over Firing Of Burner ..............................................................24
Maintaining Correct Pilot-Flame ........................................... 24
How To Access Components ................................................24
Valve Assembly ......................................................................25
INSTALLATION CHECKLIST .............................................. 26
LIGHTING CHECKLIST ..................................................... 26
OPERATION INFORMATION .......................................... 26
Using Your Remote Control ....................................................26
Synchronizing The Remote Control .......................................26
Remote Control Functions .....................................................27
Automatic Safety Restart ......................................................28
Turn On Function .....................................................................28
Turn Off Function ..................................................................... 28
Understanding Your Remote-Control Icons ......................... 28
Icon Details .............................................................................28
IPI And CPI Modes .................................................................. 29
Setting To IPI Or CPI Mode ..................................................... 29
FIRST-TIME LIGHTING INSTRUCTIONS ............................. 30
Safety Information ..................................................................30
Operating Instructions ............................................................30
Turning Off ...............................................................................30
FREQUENTLY ASKED QUESTIONS ................................... 31
Where Can I Find The Model And Serial Numbers? ............31
What Happens When First Lit? ...............................................31
Additional Curing Information ...............................................32
Can I Operate During Power Outages? ...............................32
What Is The Required Annual Maintenance? ......................32
How Do I Clean The Glass? ...................................................32
TABLE OF CONTENTS
4
Is My Flame Appearance Correct? .....................................32
What Should I Do If Sooting Occurs? .................................... 33
How Do I Change From °C To °F On My Remote? ...............33
How Do I Set The Child-Lock Mode? ....................................34
Changing The Batteries In My Remote Control? .................34
Why Did My Thermostat Disappear From My Remote? .....34
Why Won’t It Turn On? ...........................................................34
ADJUSTMENT .................................................................. 34
Pressure Testing .......................................................................34
Inlet Pressure Test ....................................................................35
Manifold Pressure Test ............................................................35
Burner Flame Adjustments .....................................................35
Gas Flame Adjustment .........................................................35
TROUBLESHOOTING ....................................................... 37
Burner And Pilot System .........................................................39
Fan ...........................................................................................39
Vent System ............................................................................39
Glass Assembly ......................................................................40
TABLE OF CONTENTS
5
APPLIANCE DIMENSIONS
B
A
Electrical
Access
L
M
K
N
E
D
C
F
Gas Line
Access
J
H
G
Physical Dimensions
inches mm
A Back Width 20 - 7/8 530
B Depth 14 - 11/16 373
C Height 24 - 1/16 613
D Width 32 - 7/16 824
E Firebox Opening Width 28 - 5/8 727
F Firebox Opening Height 17 - 11/16 449
G Back To Gas Line Hole 8 - 5/8 218
H Bottom To Gas Line Access 1 - 5/8 42
J Front to Vent Center 9 - 1/2 242
K Bottom To Electrical Access 1 - 11/16 43
L Back To Electrical Access 8 - 1/2 216
M Back Height 19 - 1/2 496
N Back to Vent Center 5 - 1/16 129
OVERVIEW
6
PART ASSEMBLY OVERVIEW
Failure to position the parts in accordance with these diagrams or failure to use only parts specically approved with this
appliance may result in property damage or personal injury.
Part Description
A Latch glass assembly
B Ember bed
C Control valve with burner assembly
D Control module
E Refractory panels
F Fireplace insert
G Co-linear exhaust/air duct
H Log set (not shown)
OVERVIEW
D
B
A
C
E
F
G
7
SAFETY LABEL
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property
damage, personal injury, or loss of life.
A. This appliance is equipped with an ignition device that automatically
lights the pilot. Do
not try to light the pilot by hand.
B. BEFORE OPERATING, smell around the appliance area for gas. Be
sure to smell next to the floor because some gas is heavier than air and
will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in your
building.
Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to turn the gas control manual valve. Never use
tools. If the valve will not turn by hand, do
not try to repair it; call a
qualified service technician. Force or attempted repair may result in a
fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician inspect the appliance
and to replace any part of the control system and any gas control that
has been under water.
1. STOP! Read the safety information above on this label.
2. Press the wireless remote OFF button.
3. Turn off all electric power to the appliance.
4. This appliance is equipped with an ignition device which automatically
lights the pilot. Do not try to light the pilot by hand.
5. Locate th
e manual valve installed by your qualified service technician.
6. Turn the manual valve clockwise to the OFF position.
7. Wait five (5) minutes to clear out any gas. Then, smell for gas, including
near the floor. If you smell gas, STOP! Follow "B" in the safety
information above. If you do not smell gas, go to the next step.
8. Turn the manual valve counterclockwise to the ON position.
9. Turn on all electric power to the appliance.
10. Press the wireless remote ON button.
11. If the appliance will not operate, follow the instructions, "The Turn Off
Gas To Appliance" and call your service technician or gas supplier.
1. Press the wireless
remote OFF button.
2. Turn off all electric power to the appliance if service is to be
performed.
3. Locate the manual valve installed by your qualified service
technician.
4. Turn the manual valve clockwise to OFF position.
OPERATING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
ON
OFF
ON/OFF
853070










!
When this replace is initially lit, condensation will appear on the glass. This is normal in all gas replaces and will
disappear after several minutes. A paint smell will occur during the rst few hours of burning. It is recommended to
leave the fan off during this period to help speed the paint curing process. This replace may produce noises of
varying degree as it heats and cools due to metal expansion and contraction. This is normal, and does not affect
the performance or longevity of the replace.
This image is only an example. The label on the actual unit will vary slightly.
OVERVIEW
8
REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS
The following requirements reference various Massachusetts
and national codes not contained in this manual. For all
sidewall horizontally vented gas fueled equipment installed
in every dwelling, building or structure used in whole or in part
for residential purposes, including those owned or operated
by the Commonwealth and where the side wall exhaust vent
termination is less than (7) feet above nished grade in the
area of the venting, including but not limited to decks and
porches, the following requirements shall be satised:
Installation of Carbon Monoxide Detectors
At time of installation of side wall horizontally vented gas
fueled equipment, the installing plumber or gas-tter shall
observe that a hard wired carbon monoxide detector with an
alarm and battery back-up is installed on the oor level where
the gas equipment is to be installed. In addition, the installing
plumber or gas-tter shall observe that a battery operated or
hard wired carbon monoxide detector is installed on each
additional level of the dwelling, building or structure served
by the side wall horizontal vented gas fueled equipment. It
shall be the responsibility of the property owner to secure the
services of qualied licensed professionals for the installation
of hard wired carbon monoxide detectors. In the event that
the side wall horizontally vented gas fueled equipment is
installed in a crawl space or attic, the hard wired carbon
monoxide detector with alarm and battery back-up may be
installed on the next adjacent oor level. In the event that the
requirements of this subdivision can not be met at the time
of completion of installation, the owner shall have a period
of thirty (30) days to comply with the above requirements;
provided, however, that during said thirty (30) day period, a
battery operated carbon monoxide detector with an alarm
shall be installed.
Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accordance
with the above provisions shall comply with NFPA 720 and be
ANSI/UL 2034 listed and IAS certied.
Signage
A metal or plastic identication plate shall be permanently
mounted to the exterior of the building at a minimum of eight
(8) feet above grade directly in line with the exhaust vent
terminal for the horizontally vented gas fueled heating the
appliance or equipment. The sign shall read, in print no less
the one-half inch (1/2) in size, “GAS VENT DIRECTLY BELOW.
KEEP CLEAR OF ALL OBSTRUCTIONS”.
Inspection
The state or local gas inspector of the side wall horizontally
vented gas fueled equipment shall not approve the
installation unless, upon inspection, the inspector observes
carbon monoxide detectors and signage installed in
accordance with the provisions of 248 CMR 5.08 (2) (a) 1
through 4.
Exemptions
The following equipment is exempt from 248 CMR 5.08 (2)
(a) 1 through 4: The equipment listed in Chapter 10 entitled
“Equipment Not Required To Be Vented” in the most current
edition of NFPA 54 as adopted by the Board; and Product
Approved side wall horizontally vented gas fueled equipment
installed in a room or structure separate from the dwelling,
building or structure used in whole or in part for residential
purposes.
Manufacturer Requirements
Gas Equipment Venting System Provided: When the
manufacturer of Product Approved side wall horizontally
vented gas equipment provides a venting system design
or venting system components with the equipment, the
instructions provided by the manufacturer for installation of
the equipment and the venting system shall include:
Detailed instructions for the installation of the venting
system design or the venting system components; and
A complete parts list for the venting system design or
venting system.
Gas Equipment Venting System NOT Provided
When the manufacturer of Product Approved side wall
horizontally vented gas equipment does not provide the
parts for venting the ue gases, but identies “special venting
systems”, the following requirements shall be satised by the
manufacturer:
The referenced “special venting systems” instructions shall
be included with the appliance or equipment installation
instructions and;
The “special venting systems” shall be Product Approved
by the Board, and the instructions for that system shall
include a parts list and detailed installation instructions.
A copy of all installation instructions for all Product Approved
side wall horizontally vented gas fueled equipment, all venting
instructions, all parts lists for venting instructions, and/or all
venting design instructions shall remain with the appliance or
equipment at the completion of the installation.
OVERVIEW
9
This is a vented product. It must be properly installed by a qualied service person. The glass door must be properly seated
and sealed. If this appliance is not properly installed by a qualied service person with glass door properly seated and sealed,
combustion leakage can occur. CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the
u with headaches, dizziness and/or nausea. If you have these signs, it may not have been installed properly. Get fresh air at
once! Have it inspected and serviced by a qualied service person. Some people are more affected by carbon monoxide
than others. These include pregnant women, people with heart or lung disease or anemia, those under the inuence of
alcohol, and those at high altitudes. Propane/LP gas and natural gas are both odorless. An odor-making agent is added to
each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be
present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is
your guide to safe and proper operation.
1. Installation and repair should be done by a qualied
service person. The appliance should be inspected
before use and at least annually by a professional service
person. More frequent cleaning may be required due to
excessive lint from carpeting, bedding material, etc. It
is imperative that control compartments, burners, and
circulating air passageways of the appliance be kept
clean.
2. Only use the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases
unless a certied kit is used.
3. Do not place propane/LP supply tank(s) inside any
structure. Locate propane/LP supply tank(s) outdoors. To
prevent performance problems, do not use propane/LP
fuel tank of less than 100 lbs. capacity.
4. If you smell gas:
Shut off gas supply.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
5. Never install:
In a recreational vehicle
Where curtains, furniture, clothing, or other ammable
objects are less than 36” from the front, top, or sides
of it
In high trafc areas
In windy or drafty areas
6. This appliance reaches high temperatures. Children and
adults should be alerted to the hazards of high surface
temperature and should stay away to avoid burns
or clothing ignition. It will remain hot for a time after
shutdown. Allow surfaces to cool before touching.
7. Young children should be carefully supervised when they
are in the same room as the appliance. Toddlers, young
children and others may be susceptible to accidental
contact burns. A physical barrier is recommended
if there are at-risk individuals in the house. To restrict
access to a replace or stove, install an adjustable safety
gate to keep toddlers, young children and other at-risk
individuals out of the room and away from hot surfaces.
8. Due to high temperatures, the appliance should be
located out of trafc and away from furniture and
draperies. Clothing or other ammable material should
not be placed on or near the appliance.
9. Do not modify the appliance under any circumstances.
Any parts removed for servicing must be replaced prior
to operating.
10. Turn off and let cool before servicing, installing, or
repairing. Only a qualied service person should install,
service, or repair it. Have burner system inspected
annually by a qualied service person.
11. You must keep control compartments, burners, and
circulating air passages clean. More frequent cleaning
may be needed due to excessive lint and dust. Turn off
the gas valve and pilot light before cleaning.
12. Have venting system inspected annually by a qualied
service person. If needed, have venting system cleaned
or repaired.
13. Keep the surrounding area clear of combustible materials,
gasoline, and other ammable vapor and liquids. Do not
run the appliance where these are used or stored. Do not
place items such as clothing or decorations on or around
the appliance.
14. Do not use to cook food or burn paper or other objects.
15. Never place anything on top of the appliance.
16. Do not use any solid fuels (wood, coal, paper, cardboard,
etc.) in this appliance. Use only the gas type indicated
on rating plate.
17. This appliance, when installed, must be electrically
grounded in accordance with local codes or in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical Code,
CSA C22.1.
BEFORE YOU START
Read this owner’s manual carefully and completely before trying to assemble, operate, or service. Any change to this
appliance or its controls can be dangerous. Improper installation or use can cause serious injury or death from re, burns,
explosions, electrical shock and carbon monoxide poisoning.
OVERVIEW
10
18. Do not obstruct the ow of combustion and ventilation
air in any way. Provide adequate clearances around
air openings into the combustion chamber along with
adequate accessibility clearance for servicing and
proper operation.
19. Do not use if any part has been under water. Immediately
call a qualied service technician to inspect and if
needed replace any part of the control system and any
gas control which as been under water.
20. Do not operate if any log is broken.
21. Do not use a blower insert, heat exchanger insert, or any
other accessory not approved for use with this appliance.
22. Do not operate with the glass front removed, cracked, or
broken. Replacement of the glass should be done by a
licensed qualied service person.
Product Specications
This appliance:
has been certied for use with either natural or propane gas. See appropriate data plates.
must use conversion kit to burn propane gas.
is not for use with solid fuels.
is approved for bedroom or bed sitting room installations.
must be installed in accordance with local codes if any. If none exist use the current installation code. ANSI Z223.1/NFPA
54 in the USA, CSA B149.1 in Canada.
is mobile home approved.
must be properly connected to a venting system.
is approved to be vented using DuraVent, BDM, ICC, and Olympia venting components.
The classication “noncombustible material” includes, but is not limited to stone, brick and mortar. Noncombustibles are
safe to overlay the black-painted metal face (including radiant plates) and do not pose a re hazard. Do not allow any
noncombustible nish material to extend past or interfere with opening.
The classication “combustible material” includes, but is not limited to plywood, drywall and particle board. Combustible
materials may contact the sides, bottom or back of rebox. Do not overlay the black painted face with combustible materials.
Controls
PRODUCT FEATURES
Never connect this appliance to private (non-utility) gas wells. This gas is commonly known as wellhead gas.
PLEASE READ THE FOLLOWING CAREFULLY It is not unusual to have some odor during the rst burn. This is
due to the manufacturing process. Please ensure that your room is well ventilated during burn off — open
all windows. It is recommended that you burn your replace for at least ten (10) hours the rst time you
use it. Place the fan switch in the “OFF” position during this time.
IMPORTANT
OVERVIEW
Valve Regulator
Master On/Off Switch
Air Shutter Adjustment
11
High Elevations
This appliance may be installed at higher altitudes. Please refer to National Fuel Gas Code ANSI Z223.1/NFPA 54, CSA-B149.1
Natural Gas and Propane Installation Code, local authorities, or codes having jurisdiction in you area regarding derate
guidelines.
US Installations - Refer to the American Gas Association guidelines for the gas designed appliances derating method. For
elevations above 2,000 ft (610 m), input ratings are to be reduced by 4% for each 1,000 ft (305 m) above sea level.
Canadian Installations - When the appliance is installed at elevations above 4,500 ft (1,372 m), the certied high altitude rating
shall be reduced at the rate of 4% for each additional 1,000 ft (305 m).
Failure to follow these instructions will void the warranty.
This appliance must be vented to the outside. The venting system must NEVER be attached to a chimney serving a separate
solid fuel burning appliance. Each gas appliance must use a separate vent system. Do not use common vent systems.
Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury,
property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious
injury, property damage or loss of life.
Do not pack the open air spaces with insulation or other materials. This could cause high temperatures and may present
a re hazard and serious injury, property damage or loss of life. Operation of improperly installed and maintained venting
system could result in serious injury, property damage or loss of life.
PART OVERVIEW
Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and
immediately inform your authorized dealer if any damage is found. Do not install any damaged, incomplete, or substitute
parts. Check your packing list to verify that all listed parts have been received.
AA BATTERIES
(4 PACK)
REMOTE
9V BATTERY
BOX
AAA BATTERIES
(3 PACK)
Gas Pressures
Natural Propane (LP)
Inlet Minimum 5.0” w.c. 12.0” w.c.
Inlet Maximum 10.5” w.c. 14.0” w.c.
Manifold Pressure 3.8” w.c. 11.0” w.c.
Gas Specications & Orice Size
Fuel
Max. Input
BTU/h
Min. Input
BTU/h
Orice
Size
Nat. 26,000 14,000 #42
LP 24,000 12,000 #54
Natural Gas LP Gas
OVERVIEW
12
Chimney Specications
This replace insert is to be installed into a solid fuel masonry or factory built non-combustible replace that has been installed
in accordance with the national, provincial, state, and local building codes.
The existing chimney must be comprised of one of the following:
Factory-built solid fuel chimney: 7 in (178mm) minimum inside diameter
Masonry chimney: 6 in x 8 in (152mm x 203mm) minimum inside diameter
inches mm
A Height 25-1/2 648
B Front Width 33 839
C Depth 17 432
D Back Width 21 534
C
A
B
D
EXISTING FIREPLACE REQUIREMENTS
Due to high surface temperatures, the replace insert should be located out of trafc and away from furniture and draperies.
Any chimney clean-outs must t properly.
Appliance Placement Considerations
This replace insert must be installed on a level surface capable of supporting the replace insert and venting.
This replace insert may be installed in a bedroom.
Please be aware of the large amount of heat this replace insert will produce when determining a location.
Existing Fireplace Specications
Any smoke shelves, shields, and bafes may be removed if attached by mechanical fasteners. If necessary, remove
rebrick to obtain at least the minimum opening requirements.
Cutting of any sheet metal parts of the existing replace is prohibited.
If the metal oor is removed, the insert must be placed directly on metal base of metal replace. Mechanically attach
‘THIS UNIT HAS BEEN MODIFIED’ label at bottom of existing rebox so it will be visible if this gas replace insert is removed.
Existing Fireplace Opening Minimum Requirements
Adequate accessibility clearances for servicing and proper operation must be maintained.
IMPORTANT
INSTALLATION
13
Existing chimney height:
Minimum: 10 ft (3.05 m) Maximum: 35 ft (10.67 m)
Determine Length of Existing Chimney
1. Remove and discard existing chimney cap.
2. It is helpful to have two people complete this step. Position one person at the replace
and another person at the top of the chimney.
3. Measure from the replace base to the top of the chimney.
4. Subtract the height of the insert from the previous measurement. This is the total length of
the co-linear exible aluminum pipe required for your installation.
INSTALLATION
MIN:
10 ft (3.05m)
MAX:
35 ft (10.67m)
Vent Termination Clearances
This appliance must not share or be connected to a chimney ue serving any other appliance.
TERMINATION LOCATION
Approved vent caps require 12 in (305mm) clearance to intersecting walls, overhangs or eaves as veried by test.
12
x
H
LOWEST
DISCHARGE
OPENING
APPROVED CAP
APPROVED
VENT PIPE
ROOF PITCH = x/12
H - MINIMUM HEIGHT FROM ROOF TO
LOWEST DISCHARGE OPENING
MINIMUM
12” (.30m)
Vertical Vent Cap Clearance
Minimum Height (H) From Roof
Roof Pitch Feet Meters
Flat to 6/12 1.0 0.30
Over 6/12 to 7/12 1.25 0.38
Over 7/12 to 8/12 1.5 0.46
Over 8/12 to 9/12 2.0 0.61
Over 9/12 to 10/12 2.5 0.76
Over 10/12 to 11/12 3.25 0.99
Over 11/12 to 12/12 4.0 1.22
Over 12/12 to 14/12 5.0 1.52
Over 14/12 to 16/12 6.0 1.83
Over 16/12 to 18/12 7.0 2.13
Over 18/12 to 20/12 7.5 2.27
Over 20/12 to 21/12 8.0 2.44
14
INSTALLATION
Minimum Termination Clearances
V
X
= Vent terminal
Legend:
= Air supply inlet
= Air where terminal is not permitted
D
E
C
V
V
V
V
V
V
V
G
X
X
V
V
K
B
Fixed
closed
Inside corner
detail
Fixed
closed
Operable
Operable
B
B
B
F
J
I
M
H
A
A
D
B
Canadian installation
1
US installations
2
A
Clearance above grade,
veranda, porch, deck, or
balcony
12 in (30 cm) 12 in (30 cm)
B
Clearance to window or
door that may be opened
6 in (15 cm) for appliances < 10,000 Btu/h
(3 kW), 12 in (30 cm) for appliances >
10,000 Btu/hr (3 kW) and < 100,000 Btu/h
(30 kW), 36 in (91 cm) for appliances >
100,000 Btu/h (30 kW)
6 in (15 cm) for appliances < 10,000 Btu/h
(3 kW), 9 in (23 cm) for appliances >
10,000 Btu/hr (3 kW) and < 50,000 Btu/h
(15 kW), 12 in (30 cm) for appliances >
50,000 Btu/h (15 kW)
C
Clearance to permanently
closed window
* *
D
Vertical clearance to
ventilated soft located
above the terminal within a
horizontal distance of 2 feet
(61 cm) from the center line
of the terminal
* *
15
This gas replace insert is approved for installation in masonry and factory-built solid fuel burning replaces.
Any removed parts must be capable of re-installation if this insert is ever removed. Removal of rivets or
screws is acceptable.
IMPORTANT
INSTALLATION PREPARATION
Inspect and Clean Existing Chimney
Verify existing chimney is constructed of non-combustible material.
Verify existing chimney is clean and in good working order. Clean existing chimney and replace to prevent a creosote odor
from entering the home.
Verify combustible mantel and sidewall clearances comply with the Safety Barrier Installation section of this manual.
The refractory, glass doors, screen rails, screen mesh, and log grates may be removed from existing replace before installing
this gas replace insert.
Flue Damper
The appliance ue damper can be fully blocked open, or removed for installation of this gas replace insert. Remove existing
chimney cap.
Gas Line
A gas line must be able to be installed to the insert (see the Gas Line Connection section of this manual).
If the factory-built replace has no gas access hole(s) provided, an access hole of 1-1/2 in. (37.5 mm) or less may be drilled
through the lower sides or bottom of the rebox in a proper workmanship like manner. The access hole must be plugged with
non-combustible insulation after the gas supply line has been installed.
Run gas line to the gas replace insert through the gas line hole provided. Do not run gas line in a manner that would obstruct
fan operation.
If the gas replace insert is to be installed into minimum opening dimensions, the gas line may need to be run after appliance
placement due to space limitations.
Electrical Wiring
Provisions must be made to provide electrical power for appliance operation.
Refer to the Appliance Dimensions section of this manual for electrical outlet box location to run any necessary electrical
wiring to the gas replace insert.
Fireplace Conversion
Mechanically attach the label with the following warning to at the bottom existing rebox so it will be visible if this gas replace
insert is removed.
WARNING:
THIS FIREPLACE HAS BEEN CONVERTED FOR USE WITH A GAS FIREPLACE
INSERT ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID FUELS
UNLESS ALL ORIGINAL PARTS HAVE BEEN REPLACED, AND THE FIREPLACE
RE-APPROVED BY THE AUTHORITY HAVING JURISDICTION.
AVERTISSEMENT:
CE FOYER A ÉTÉ CONVERTI POUR UTILISATION AVEC UN FOYER AU GAZ
ENCASTRABLE ET NE PEUT ÊTRE UTILISER POUR BRÛLER DU BOIS OU
D'AUTRES COMBUSTIBLES SOLIDES À MOINS QUE TOUTES LES PIÈCES
D'ORIGINE AIENT ÉTÉ REMPLACÉES ET QUE LE FOYER AIT ÉTÉ APPROUVÉ DE
NOUVEAU PAR L'AUTORITÉ COMPÉTENTE.
853071
INSTALLATION
16
Proper operation of this insert requires the exhaust and combustion air pipes to be connected to the
correct collar, on both the termination kit and the gas replace insert air duct. The replace insert air
duct exhaust is located on the right side. Install termination cap on the right side
IMPORTANT
All information outlined in the “Installation Preparation” section of this manual must be completed before
continuing with this installation.
IMPORTANT
INSTALLATION
INSTALLATION
Co-Linear Vent System
1. Carefully extend the exhaust and combustion air intake pipes to total chimney length required.
2. Slide the combustion air intake pipe over termination cap collar. Secure to termination cap with three (3) self-tapping
screws.
3. Place a bead of high temperature sealant around the inner edge at the end of the exhaust pipe and slide onto the
termination cap.
4. Secure the exhaust pipe to termination cap with the three (3) self-tapping screws. Apply additional high temperature
sealant around joint to ensure a proper seal.
5. Complete vent system installation as shown in this manual.
Remove Air Duct
Remove the air duct at the top of appliance by sliding the air duct back out of channels. Refer to the following instructions
for vent system attachment to the air duct.
EX = Exhaust Pipe
17
Proper operation of this appliance requires exhaust and combustion air pipes to be connected to the
correct collar, on both the termination kit and the gas replace insert air duct.
IMPORTANT
INSTALLATION
If offsets are present in existing chimney, place a weighted rope around
the pipe ends to guide them through the chimney. DO NOT ATTEMPT TO
TIE ONE ROPE AROUND BOTH PIPES.
Run Vent System
To prevent cold air drafts, it is recommended to insulate the 3” x 3” exible vent
pipes and chimney using unfaced insulation products listed as noncombustible
per ASTM E 136.
1. OPTIONAL: Before installing vent system down through the chimney, place
unfaced insulation around the rst 3 ft (914 mm) of vent system below termination
cap. Secure with wire.
2. Install the 3” x 3” exible pipes down through existing chimney. Guide ropes (if
used) to aid installation.
3. To secure chimney termination cap to chimney, apply a liberal bead of high
temperature sealant around the top of the chimney. Set termination cap into
position as instructed by vent system manufacturer’s installation manual.
4. From inside the existing replace, carefully pull ropes (if used) or the exible pipes
down until both exhaust pipe and combustion air intake are into the existing
replace rebox.
5. OPTIONAL: To prevent heat loss up chimney, place unfaced insulation products
between the 3” x 3” exible vent pipes and chimney.
Connect Vent Pipe to Air Duct
1. Place previously removed air duct into existing replace opening.
2. Connect exhaust vent pipe to exhaust collar on air duct. Apply a bead of high temperature sealant around exhaust pipe
and slide inside. Secure with three (3) 1/2 in (13 mm) self-tapping screws. Apply additional high temperature sealant around
join to ensure an air tight seal.
3. Connect air intake vent pipe to air duct. Apply a liberal bead of high temperature sealant around intake on air duct.
Slide on the combustion intake pipe and secure with three (3) 1/2 in (13 mm) self-tapping screws. Apply additional high
temperature sealant around joint to ensure an air tight seal.
4. Visually check vent pipe connection to air duct.
Chimney Vent Run
This appliance is approved to be vented using DuraVent, BDM, ICC, and Olympia venting components
AIR DUCT
Air Duct in Existing Fireplace
ALIGNED
GAS INSERT
Aligned Gas Insert in Existing Fireplace
18
INSTALLATION
FLEXIBLE PIPES
SHEET METAL
SCREWS (3 TOTAL)
SEALANT
SEALANT
Secured Vent Pipes to Air Duct
Seated Air Duct
(shown without venting attached for clarity purposes only)
PULL ROD
SECURE WITH
(2) SCREWS
Place and Secure Appliance
1. Slide the gas replace insert into existing replace opening until the channels on top of the appliance are aligned with the
air duct.
2. Insert the air duct pull rod handle through access slot at the top of appliance and place pull handle hook through the hole
in pull rod. Simultaneously push the gas insert into existing replace and pull the air duct forward until seated.
3. Secure air duct to appliance by using slots at the top of the appliance to secure with two (2) 1/2 in (13 mm) sheet metal
screws.
4. Use the pull rod handle to pull the air duct back to starting position. Remove pull handle. Verify vent system connection.
5. If necessary, level the gas insert by threading leveling bolts into nuts at the bottom of the insert (2 each side). Verify appliance
is properly positioned.
19
GAS LINE CONNECTION
Gas Conversion (sold separately)
The conversion shall be carried out in accordance with the requirements of the provincial authorities
having jurisdiction and in accordance with the requirements of the ANSI Z223.1 installation code.
IMPORTANT
This replace is manufactured for use with natural gas. Follow the instructions included with the conversion kit if converting to
LP gas.
Gas Line Installation
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at pressures in excess of 1/2 psi (3.5 kPa). For test pressures equal to or less than 1/2
psi (3.5 kPa), the appliance must be isolated from the gas supply piping system by closing its individual manual
shut-off valve.
Installation of the gas line must only be done by a qualied person in accordance with local
building codes, if any. If not, follow ANSI 223.1. Commonwealth of Massachusetts installations
must be done by a licensed plumber or gas tter.
A listed (and Commonwealth of Massachusetts approved) 1/2 in. (13 mm) tee handle manual shut-off valve and exible gas
connector are to be connected to the 1/2 in. (13 mm) control valve inlet. If substituting for these components, please consult
local codes for compliance.
If installing this insert into minimum opening dimensions, the gas line may need to be run after placement due to space
limitations (see the Existing Fireplace Opening Minimum Requirements section of this manual).
This replace is equipped with a ⅜” (10 mm) x 18” (457 mm) long exible gas connector and manual shut-off valve.
Run gas line into replace, preferably through left or right gas line holes provided. The gas line should be run to the point
of connection where the shut-off valve and exible gas line will connect.
Do not run gas line in a manner that would obstruct fan operation.
For high altitude installations, consult the local gas distributor or the authority having jurisdiction for proper rating methods.
Inlet Gas Supply Pressures
Fuel Minimum Pressure Maximum Pressure
Natural Gas 5” WC (1.25 kPa) 10.5” WC (2.62 kPa)
LP Gas 12” WC (2.99 kPa) 14” WC (3.48 kPa)
INSTALLATION
FACING AND FINISHING
Clearances to Combustibles
12”
(305mm)
35.5”
(902mm)
10”
(254mm)
COMBUSTIBLE
MANTEL
COMB
USTIBLE
M
ATERIAL
9” (229mm) CLEARANCE
TO ADJACENT SIDEWALL
Mantel Requirements
20
GAS FIREPLACE INSERT SETUP
Glass Frame Assembly
Do not operate this replace with the glass removed, cracked, or broken. Replacement of the glass assembly should be
done by a licensed or qualied service person.
Do not remove the glass assembly when hot.
Remove Glass Assembly
This replace should not be burned without the approved logs, surrounds, and liners properly installed. Use without
the logs, surrounds, and liners properly installed could cause damage to the appliance.
LOG, LINER, SAFETY BARRIERS, & SURROUND INSTALLATION
If converting to LP (propane) gas, complete the conversion before installing the log set. Follow the conversion instructions
included with the kit.
Refer to the instruction sheets provided with your log and liner set for proper installation.
Only log and liner sets certied with the appliance shall be used.
Do not place logs directly over burner port holes. Improper log placement may affect ame
appearance and cause excessive soot to build upon the logs and glass.
Use only authorized parts and materials when replacing defective or damaged glass.
INSTALLATION
Certied Log Sets
Ridgewood Timber (AH2818LGRT)
Riverside (AH2818LGR)
Certied Surrounds
AH2818SSM
AH2818SLG
Certied Liner Sets
Aged Red Brick (AH2818LARB)
Black Tie (AH2818LBT)
Baker Street (AH2818LBAK)
Frisco Ledgestone (AH2818LFL)
Consider the height of hearth nish material when building a platform. Proper installation of safety
barriers with an overlap t design require the bottom of the replace to be level with nished hearth. For
installation instructions refer to “Safety Barrier Installations”.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be
installed for the protection of children and other at-risk individuals. If the barrier becomes damaged, the barrier shall be
replaced with the manufacturer’s barrier for this appliance. Only doors certied with the appliance shall be used.
IMPORTANT
Do not operate this appliance without a safety barrier. Only safety barriers certied with the appliance shall be used. Only trim
kit(s) supplied by the manufacturer shall be used in the installation of this appliance. Any trim panels or surrounds must not seal
ventilation openings in existing replace that this appliance is installed in.
Certied Safety Barriers
AH2818ART
AH2818FF3
AH2818FF5
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80

Breckwell BH2818i Manuel utilisateur

Catégorie
Cheminées
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues