Dyna Glo EG10000DH Le manuel du propriétaire

Catégorie
Chauffe-eau
Taper
Le manuel du propriétaire
Before the rst use of this heater, please read this USER’S MANUAL
very carefully. This USER’S MANUAL has been designed to instruct
you as to the proper manner in which to assemble, maintain, store,
and most importantly, how to operate the heater in a safe and efcient
manner. Please keep this manual for future reference.
CONSUMER: Retain this manual for future reference.
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 877-447-4768 8:00 a.m. - 4:30 pm CST, Monday - Friday.
or email us at [email protected]
IMEG10000DH-2019-10-15
Electric Garage Heater
INSTALLATION & MAINTENANCE INSTRUCTIONS
10,000W / 240V / 34,120 BTU
EG10000DH
CSA C22.2 No. 46-13
UL 2021
PET OWNERS WARNING: The health of some small pets including birds are extremely
sensitive to the fumes produced during the rst-time use of many appliances. These fumes are
not harmful to humans but we recommended that you do not use your heater around birds and
small pets during its initial use until the manufacturing corrosion coatings burn off.
When using electrical appliances, basic precautions should always be followed to
reduce the risk of re, electric shock, and injury to persons, including the following:
1. Read all instructions before installing or using this heater.
2. This heater is hot when in use. To avoid burns, do not let bare skin touch hot
surfaces. Keep combustible materials, such as electrical cords, furniture,
pillows, bedding, papers, clothes, and curtains at least 3 feet (0.9 m) from the
front of the heater and keep them away from the sides and rear.
3. Extreme caution is necessary when any heater is used by or near children or
invalids and whenever the heater is left operating and unattended.
4. Always turn off the power to the heater when not in use.
5. Do not operate any heater after the heater malfunctions, has been dropped or
damaged in any manner. Disconnect power at the service panel and have the
heater inspected by a reputable electrician before reusing.
6. Do not use outdoors.
7. This heater is not intended for use in bathrooms, laundry areas and similar
indoor locations. Never locate heater where it may fall into a bathtub or other
water container.
8. Do not insert or allow foreign objects to enter any ventilation or exhaust
opening as this may cause an electric shock or re, or damage the heater.
9. To prevent a possible re, do not block air intakes or exhaust in any manner.
Do not use on soft surfaces, like a bed, where openings may become blocked.
10. A heater has hot and arcing or sparking parts inside. Do not use it in areas
where gasoline, paint, or ammable liquids are used or stored.
11. Use this heater only as described in this manual. Any other use not
recommended by the manufacturer may cause re, electric shock, or injury to
persons.
12. To disconnect heater, turn controls to off, and turn off power to heater circuit at
main disconnect panel.
13. If the red alarm light on th front of he unit illuminates, immediately turn the
heater off and inspect for any objects on or adjacent to the heater that may
have blocked the airow or otherwise caused high temperaturs to have
occurred. DO NOT OPERATE THE HEATER WITH THE ALARM LIGHT
ILLUMINATING.
IMPORTANT INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This Product can expose you to chemicals including Diisononyl phthalate (DINP) which is known
to the State of California to cause cancer and Di-isodecyl phthalates (DIDP) which is known to the
State of California to cause birth defects or other reproductive harm.
For more information go to www.p65Warnings.ca.gov
WARNING
2
3
ITEM PAGE #
SPECIFICATIONS ........................................................................... 3
SAFETY INFORMATION ................................................................. 3
LOCATING HEATER ....................................................................... 4
PRE-INSTALLATION ....................................................................... 5
INSTALLATION ............................................................................... 6
OPERATING INSTRUCTIONS ........................................................ 10
MAINTENANCE .............................................................................. 12
REPLACEMENT PARTS ................................................................. 12
TROUBLESHOOTING .................................................................... 13
1. Use only copper wires rated for at least 60ºC.
2. Heaterairowmustbedirectedparalleltoorawayfromadjacentwall.
3. Observeallwall,oorandceilingclearancerequirements.
4. Allwiringmustbedoneaccordingtonationalandlocalelectricalcodes.The
  heatermustbegroundedasaprecautionagainstpossibleelectricalshock.
  Heatercircuitmustbeprotectedwithproperfuses.
5. Themountingstructureandtheanchoringhardwaremustbecapableof
  supportingtheweightoftheheaterandthemountingbracket(ifused).
Rating AMPS BTU/hour
10000W II 240-1-60 41.66 34120
7500W I 240-1-60 31.25 22589
TABLE OF CONTENTS
SPECIFICATIONS
SAFETY INFORMATION
THISHEATERREQUIRESHARDWIREINSTALLATION(NOPLUG).THEINSTALLATIONOFTHIS
PRODUCT MUST BE CARRIED OUT BY A CERTIFIED ELECTRICIAN AND IN ACCORDANCE WITH
ALL LOCAL AND NATIONAL ELECTRICAL CODES.
NOTE: COMPATIBLE WITH A 240V LINE VOLTAGE DOUBLE POLE WALL THERMOSTAT. MUST BE
INSTALLED BY A CERTIFIED ELECTRICIAN.
READ AND UNDERSTAND ALL INSTALLATION & OPERATION INSTRUCTIONS PRIOR TO
OPERATING THIS UNIT. OBSERVE ALL SAFETY INSTRUCTIONS.
WARNING
4
6. Allelectricalpowermustbedisconnectedatthemainservicebox,which
  mustbelockedbeforeconnecting,inspecting,cleaningorservicingthe
  heater.Thisisanimportantprecautiontopreventseriouselectricshock.
7. Thisisheaterisnotsuitableforuseinhazardouslocationscontaining 
  explosiveliquidsorvapours.Thisheaterhashotorarcingorsparkingpads
  inside.Donotuseitinareaswheregasoline,paintorammableliquidsare
  usedorstored.
8. Thisheaterisnotsuitableforuseincorrosiveatmospheressuchasmarine
  greenhousesorchemicalstorageareas.
9. Thisheatermustbemountedatleast8feetofftheoor.Forspecic
  clearances,pleaseseenextpage.
Installheaterawayfromtrafcareas,maintainingclearancesstatedingure
2(below).Theairowdirectionshouldnotberestricted(ie.bycolumnsor
machinery).Theairowshouldwipeexposedwallsratherthanblowingdirectly
onthem.Whenmorethanoneheaterisusedinanarea,heatersshouldbe
installedsothattheairdischargeofeachheatersupportstheairowofthe
others,toprovidebestwarmaircirculationasshowningure3.
Figure 2
SAFETY INFORMATION
LOCATING HEATER
IMPROPER INSTALLATION OR FAILURE TO FOLLOW THE PROCEDURES OUTLINED IN THIS
INSTRUCTION MANUAL CAN RESULT IN SERIOUS ELECTRICAL SHOCK.
WARNING
5
Part Description Quantity
AGarageHeater 1
BMountingBracket 1
CInfraredRemoteControl 1
D Screw 6
EWasher 12
PRE-INSTALLATION
LOCATING HEATER
Figure 3
6
WoodCeiling WoodCeiling
MOUNTING THE BRACKET
RefertoFigures4aand4b.
1.Locateawoodstudinthewoodceilingjoist.Ifyoucannotlocateawood
  stud,youhavetoinstallawoodpieceontheceilingasthisheatermustbe
  securelyfastened.
2.Removethemountingbracketfromtheheatingunitbylooseningbracket
  screwswithawrenchandslippingthehandleoffoverthescrewheads.
3.Placeawasheronscrewsbeforeinsertingthroughtheholesinthemounting
  bracketandscrewthemsecurelyintoaceilingjoist.
NOTE:Ifyouwanttoswiveltheheatereithertotherightorleftaddingawasher
tobothsidesofthebracketisrecommended.Alongerlagboltmayberequired
toproperlysecuretheunit.SeeFigure4a.
HANGING THE HEATER
1. Attachtheheatingunittothemountingbracket.
2. Lifttheheaterupandintothemounting
  bracket.
3. Alignthebracketscrewswiththekeyholeslots
  inthemountingbracket.
4. Iftheheateristobetilteditmustbepositioned
  inthekeyholeslots-seegure5.
5. Tightenthebracketscrewswithawrenchso
  theunitissecurelysuspendedathorizontalor
  verticallevel.
Figure 5
ADJUSTING AIR FLOW DIRECTION
1.Toturntheunitwhenithasbeeninstalled
withasinglelagbolt(asshowningure
4a),simplyturntheentireheaterasneeded.
Theunitcannotbeturnedhorizontallyifit
hasbeeninstalledwith2lagbolts.
2.Totilttheunitvertically,loosenthebracket
screws(seegure5).
Figure 4a. Single-Screw Mounting Figure 4b. Double-Screw Mounting
INSTALLATION
7
MULTIPLE VERTICAL ANGLES
3.Adjustlouverstothedesiredposition(seeFigure6).
NOTE: Thelouversaredesignedsotheycannot
becompletelyclosed.Donotattempttobypassthis
feature;damagetotheunitcanresult.
INSTALLATION
NOTE: Fortheheatertobetiltedvertically,itmustbemountedinbottomkeyhole
slotsofmountingbracketstomaintainadequateclearanceandpreventpossible
overheating.
Figure 6
TOPREVENTPOSSIBLEELECTRICSHOCK,DISCONNECTPOWERTOTHEHEATERATTHE
MAIN SERVICE BOX BEFORE ATTEMPTING TO ADJUST THE HEAT OUTPUT OF THIS UNIT.
WARNING
8
Selection Switch
(Heater’s thermostat, External thermostat)
Heater’s
thermostat
External
thermostat
CONNECTING THE POWER
If you will use an external temperature control (external thermostat) to control
the heater to be operated or not, please follow below attention points:
1.Makesurethattheheater'stemperaturecontrolknob(thermostatknob)isturned
fullyclockwise.
2.Connectthewireaccordingtobelowwiringdiagram.
INSTALLATION
GND
E
L1
L2
1
2
240AC or 208AC
60HZ
External
thermostat
PCB
Selected
switch
2500W
3750W 3750W
GND
E
L1
L2
1
2
240AC or 208AC
60HZ
External
thermostat
PCB
Selected
switch
2500W
3750W 3750W
3
4
LINE
RED LOAD
BLACK
External thermostat
Terminal station
1
2
9
CONNECTING THE POWER
3.Theexternaltemperaturecontrol(externalthermostat)shouldbein
accordancewiththerequirementofULorCSAstandard.
4.Theleadwireofexternaltemperaturecontrol(externalthermostat)cannot
belessthan14AWG.
1.Removethescrewfromthefrontoftheunittoconnectthepowertotheheater.
2.Attachthecableconnectorstotheunit(SeeFigure7)andslidethe10-gauge
wirethroughthecableconnector.
3.Connectthewiretothepowerblocklocatedinthebaseoftheheater-See
Figure7.
4.Turnonthepoweratthemainservice.
NOTE:AllwiringmustbecarriedoutbyaCertiedElectricianandmustbein
accordancetonationalandlocalelectricalcodes.Forcertainapplications,conduit
mayberequired,SeeFigure7.Checklocalelectricalcodes.Ifyourunthewiringin
conduitandwishtobeabletoturntheheaterbesuretopurchaseenoughexible
conduittoallowtheheatertobeturned.
TO PROTECT THE HEATING ELEMENT
Whenstartingtheheater,turningthetemperaturecontrolclockwiseslowlytoterminal,
theunitstartsthefanrstthenstartstheheatingelement.
Whenshuttingofftheheater,turningthetemperaturecontrolcounter-clockwisetooff,
theheatingelementrstwillturnoffthenthefanwillrunashortcoolingcycleandthen
turnoff.
INSTALLATION
THIS APPLIANCE MUST BE GROUNDED!
THE APPLIANCE MUST CONNECT TO A CURRENT PROTECTION CIRCUIT OR DEVICE AT
50AMP OR LESS BEFORE BEING CONNECTED TO POWER SUPPLY!
WARNING
HIGHTEMPERATURES–RISKOFFIRE.KEEPFLAMMABLEMATERIALS,SUCHAS
FURNITURE,PILLOWS,BEDDING,PAPERS,CLOTHES,ELECTRICALCORDSANDCURTAINS
ATLEAST3FT.(0.9M)FROMTHEFRONTANDTOPOFTHEHEATERANDKEEPTHEMAWAY
FROMTHESIDESANDREAR.TOREDUCETHERISKOFFIRE,DONOTUSEITINAREAS
WHEREGASOLINE,PAINTORFLAMMABLELIQUIDSAREUSEDORSTORED.
WARNING
TOREDUCETHERISKOFFIRE,DONOTSTOREORUSEGASOLINEOROTHER
FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THE HEATER.
WARNING
10
CONNECTING THE POWER
Connectors,cable,andhardwareusedto
wiretheheater Figure 7
Conduit
Connector
Conduit
FlexibleConduit
FlexibleNMCable FlexibleNMCableConnector
FlexibleConduitConnector
WHITE
BLACK
GREEN
(orbarecopper)
3ft
INSTALLATION
OPERATING INSTRUCTIONS
THE HEATER MUST BE PROPERLY INSTALLED BEFORE IT IS USED.
WARNING
Control Panel
11
Checkthatthegarageheatersoutletgrillisnotcoveredorobstructedinanyway,and
makesurethepowertotheunitisswitchedon.
Thegarageheatercontrolfunctionscanbeaccessedintwo(2)ways:
•Usingthetouchpadcontrolpanel,locatedonthefrontofthegarageheaterbelowthe
airguideplates.
•Usingthemultifunctionremotecontrolunit.
1. Main Power Button:
Thisbuttonsuppliespowertoallofthegarageheatersfunctions.Itmustbeturnedon
forthegarageheatertowork
2. Heater Control Button:
Thisbuttonadjuststhe3heatingstages:OFFFa(FanOnly)LOW(7500Wdisplays
“L”),High(10000Wdisplays“H”).
3. Temperature/Timer Display:
ThisLEDdisplayshowsthesetpointforthetemperatureandtimerfunctions.When
eitherofthesefunctionsisactivated,thedisplayreectsthesetpointforveseconds
andthenfadestoblack.Anychangetohesetpointofthetemperatureortimerwill
reactivatethedisplay,whichagainfadesafterveseconds.
4. DOWN Control Button:
Thisbuttonisusedtodecreasetemperatureortimersettiing.Itadjuststhe
temperaturerangebetween10°C-35°C(50°F-95°F)in2°F(/1°C)increments.
5. UP Control Button:
Thisbuttonisincreasingtemperatureortimersetting.Itadjuststhetemperaturerange
between10°C-35°C(50°F-95°F)in2°F(/1°C)increments.
6. Timer Button:
ThisbuttoncontrolstheTimerON/OFFand8settingsfrom1hourto8hours.When
theTimerisrstturnedon,itwillcomeonattheshortesttimesetting(1hour).Each
timetheTimerbuttonispressed,thetimeincreasesby1hour,uptothelongest
setting(8hours).Oncethesettimeexpires,allgarageheatersfunctionswillbe
automaticallyturnoff.
7. Fahrenheit/Celsius Button:
REMOTE:
ThisbuttondisplaysF(Fahrenheit)orC(Celsius)dependingonhowthetemperature
modeisset.Whenthegarageheateristurnedon,theFahrenheit(F)temperaturewill
bedisplayed.
GARAGEHEATER:
ToswitchfromFahrenheittoCelsius,orvise-versa,whenthegarageheaterisON,
holdHEATERCONTROLbuttonfor5seconds.Unlesspowertotheunithasbeen
interrupted,thegarageheaterwillrememberthelasttemperaturemodesettingand
willstartatthatsetting.
OPERATING INSTRUCTIONS
12
1.Beforecleaning,makesurethepowerhasbeenturnedoffatthecircuitbreaker
panelandthattheheatingelementoftheheateriscool.
2.Tomaintaintheexternalappearanceoftheheater,theunitoccasionallyneedsto
bewipedwithadryduster.Duringthesummermonths,oratothertimeswhen
theapplianceisnotinuseandiscompletelycold,itshouldbethewipedover
withadampcloth.
3.Donotuseabrasiveclearingpowdersorfurniturepolish.Donotusechemicalor
abrasiveproducts,metallicscourersandsoon,whichmaydeterioratethesur-
face,tocleantheappliance.
4.Duringthesummermonths,oratothertimeswhentheapplianceisnotinuse,
disconnectthepowersupply.Keeptheapplianceinadryandcoolplace.
5.Allotherservicingshouldbeperformedbyqualiedservicepersonnel.Donottry
torepairtheheateryourself.
NOTE:Themotorispermanentlylubricated,andnofurtherlubricationisneeded.
Part Description Part#
1Backmesh
EG10000DH001AC
2Hangingplate
EG10000DH002AC
3 Fan Blade
EG10000DH003AC
4Airguideplate
EG10000DH004AC
5Largehandleseat
EG5000005AC
6Smallhandleseat
EG5000006AC
7Spring
EG5000007AC
8 Motor
EG10000DH005AC
Part Description Part#
9 Heater
EG10000DH006AC
10 SelectionSwitch
EG5000011AC
11 Main Board EG7500DH001AC
12 Terminalblock EG5000014AC
13 TemperatureCUT-OFF EG5000017AC
14 ControlPanelCircuitBoard EG7500DH002AC
15 ControlPanelbox EG7500DH003AC
16 InfraredRemoteControl EG7500DH004AC
MAINTENANCE
REPLACEMENT PARTS
TROUBLESHOOTING
PROBLEM DISPLAY
CODE ROOT CAUSE CORRECTIVE ACTION
Unit is not
heating
Display
shows”EE”
The thermostat sensor is
broken or disconnected. Please call customer service.
Display
shows"EF"
The overheat protection has
activated.
Inspect the garage heater and check
that the air inlets and outlets are not
blocked as this may cause overheat-
ing. Switch off the circuit breaker to
the garage heater for 30 minutes and
allow it to cool down. Turn the power
back on and operate.
Display
shows
"LOC"
Heater is in Lock Mode Hold the POWER button for 10 seconds
to unlock the heating function.
Display
shows "FA"
and blows
cold air
The heater is set to FAN
ONLY mode
Change the setting and switch to
"AUT" heating mode
The heater
will not start
The room temperature has
already reached the set
thermostat
temperature
Adjust the temperature setting to
make sure the thermostat setting
temperature is higher than current
room temperature.
The heater
will not start The breaker has tripped Rest the breaker at the fuse panel and
restart the heater
Garage
heater
emits a
burning
smell
During production dust
and/or oil debris gath-
ered on heating coils.
Make sure the room is well
ventilated. Allow the garage
heater to run until the smell is
dissipated.
Check and make sure
there is no combusti-
ble material within 0.9
meters (3 feet) of the
garage heater.
Remove the combustible materi-
al around the garage heater.
This heater must be
mounted at least 8 feet
off the oor, for specif-
ic clearances, please
check the "LOCATING
HEATER" section in the
instruction manual
Relocate the garage heater so
there is enough space between
the heater and adjacent wall and
oor.
13
PRODUCT NOTES
Warranty
LIMITED WARRANTY:
This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect
in materials and workmanship for a period of one (1) year from the date of retail sale.GHP Group, Inc., at it’s option, will either provide
replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers
as directed by GHP Group,Inc., within one (1) year of retail purchase. (Shipping costs, labour costs,etc. are the responsibility of the purchaser.)
DUTIES OF THE OWNER:
This heating appliance must be operated in accordance with the written instructions furnished with this heater. This warranty shall not excuse
the owner from properly maintaining this heater in accordance with the written instructions furnished with this heater. A bill of sale, canceled
check or payment record must be kept to verify purchase data and establish warranty period. Original carton should be kept in case of
warranty return of unit.
WHAT IS NOT COVERED:
1. Damage resulting from use of improper fuel.
2. Damage caused by misuse or use contrary to the owners manual and safety guidelines.
3. Damage caused by a lack of normal maintenance.
4. Fuses
5. Use of non-standard parts or accessories.
6. Damage caused in transit. Freight charges on warranty parts or heaters to and from the factory shall be the responsibility of the owner.
This warranty does not imply or assume any responsibility for consequential damages that may result from the use, misuse, or the lack of
routine maintenance of this heating appliance. A cleaning fee and the cost of parts may be charged for appliance failures resulting from lack of
maintenance. This warranty does not cover claims which do not involve defective workmanship or materials. FAILURE TO PERFORM
GENERAL MAINTENANCE (INCLUDING CLEANING) WILL VOID THIS WARRANTY.
THIS LIMITED WARRANTY IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED,
INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE. THE
REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES. IN NO EVENT
WILL GHP GROUP, INC. BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not
allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you.
CLAIMS HANDLED AS FOLLOWS:
1. Contact your retailer and explain the problem.
2. If the retailer is unable to resolve the problem, contact our Customer Service Dept. detailing the heater model, the problem, and proof
of date of purchase.
3. A representative will contact you. DO NOT RETURN THE HEATER TO GHP GROUP, INC. unless instructed by our Representative.
 Thiswarrantygivesyouspeciclegalrightsandyoumayalsohaveotherrightswhichvaryfromstatetostate.
TO REGISTER THE WARRANTY ON YOUR HEATER, PLEASE FILL OUT THIS CARD COMPLETELY
AND MAIL WITHIN 14 DAYS FROM DATE OF PURCHASE OR REGISTER ON-LINE AT www.ghpgroupinc.com
NAME: _______________________________ PHONE: ( ) _________________ EMAIL: ____________________________________
ADDRESS: ___________________________ CITY: ________________________ STATE: _____________________ ZIP: ___________
MODEL: ______________________________ SERIAL#: _____________________ DATE PURCHASED: _________________________
DEALER PURCHASED FROM: _________________________________________ TYPE OF STORE: __________________________
CITY & STATE WHERE PURCHASED: ___________________________________ PRICE PAID: _______________________________
Please Take 1 Minute To Give Us Your Answers To The Following Questions.
All Responses Used Solely For Market Research And Are Held In Strict Condence.
Whoprimarilydecidedthispurchase? Male Female 18-24 25-39 40-59 60andoverofage?
Doyouownanyotherportableheaters? Yes NoIfyes,type ______________________ brand ____________________________
Howdoyouintendtouseyournewheater? ConstructionSite Farm Warehouse/Commercial Garage/Outbuilding Other
Howdidyoubecomeawareofthisheater? In-Store Display Newspaper Ad MagazineAd Friend/Relative
TVCommercial Store Salesperson Other ____________________________________________________________________
Whatmadeyouselectthisheater? Style Size/Portability Price Package Brand Other __________________________
Doyou: Own RentWouldyourecommendthisheatertoafriend? Yes No
Pleasegiveusyourcomments _____________________________________________________________________________________
THANK YOU FOR COMPLETING THIS FORM!
Informationwillbeheldcondential.
WARRANTY REGISTRATION
IMPORTANT: We urge you to ll out your warranty registration card within fourteen (14)
days of date of purchase. You can also register your warranty on the internet at
www.ghpgroupinc.com. Complete the entire serial number. Retain this portion of the card
for your records.
Place
Postage
Stamp
Here
SAVE THIS CARD!
GHP Group, Inc.
6440 W Howard St
Niles, IL 60714-3302
Tel: (877) 447-4768
www.ghpgroupinc.com
GHP Group, Inc.
6440 W Howard St
Niles, IL 60714-3302
Antes de utilizar por primera vez este calentador, lea este MANUAL DEL
USUARIO atentamente. Este MANUAL DEL USUARIO ha sido diseñado
para instruirle la forma adecuada de ensamblar el calentador, brindarle
mantenimiento, guardarlo y lo más importante: cómo hacerlo funcionar de
manera segura y ecaz. Conserve este manual para referencia futura.
CONSUMIDOR: Conserve este manual para referencia futura.
¿Preguntas, problemas, partes faltantes? Antes de regresar al distribuidor,
llame a nuestro departamento de servicio al 877-447-4768 de 8:00 a.m. a
4:30 p.m. hora estándar del centro, de lunes a viernes o envíenos un correo
electrónico a [email protected].
Calefactor de garaje eléctrico
INSTRUCCIONES DE INSTALACIÓN Y MANTENIMIENTO
EG10000DH
10,000W / 240V / 34,120 BTU
CSA C22.2 No. 46-13
UL 2021
ADVERTENCIA PARA DUEÑOS DE MASCOTAS: Algunas mascotas pequeñas, incluidos los
pájaros, son muy sensibles a la exposición de los humos que se producen durante el uso de
electrodomésticos por primera vez. Estos humos no son dañinos para los seres humanos, pero
le recomendamos que no utilice el calefactor cerca de pájaros y mascotas pequeñas durante el
primer uso de la unidad hasta que los recubrimientos anticorrosivos se quemen por completo.
Al usar electrodomésticos, siempre se deben respetar las precauciones básicas para reducir
el riesgo de incendio, choques eléctricos y lesiones personales, incluidas las siguientes:
1. Lea todas las instrucciones antes de instalar o usar este calefactor.
2. Este calefactor se calienta cuando está en uso. Para evitar quemaduras, no toque las
supercies calientes con la piel descubierta. Mantenga los materiales combustibles,
como cable eléctricos, muebles, almohadas, ropa de cama, papeles, vestimenta,
cortinas, etc. a una distancia mínima de 3 pies (0,90 m) de la parte frontal del
calefactor, y alejados de los laterales y de la parte trasera.
3. Se debe tener sumo cuidado al usar calefactores junto a niños o personas inválidas,
o cerca de ellos, y en todo momento en que el calefactor se deje prendido y
desatendido.
4. Siempre desconecte la alimentación al calefactor cuando no esté en uso.
5. No ponga en funcionamiento ningún calefactor después de que haya fallado.
Desconecte la energía en el panel de servicio y haga que un electricista acreditado
inspeccione el calentador antes de reutilizarlo.
6. No lo utilice al aire libre.
7. Este calefactor no está diseñado para usarse en baños, lavaderos o lugares cubiertos
similares. No ubique el calefactor en un lugar donde pueda caerse dentro de una
bañera u otro contenedor de agua.
8. No inserte ni permita que ingresen objetos extraños en ninguna abertura de
ventilación o escape porque podrían provocar un choque eléctrico, un incendio o
daños en el calefactor.
9. Para evitar posibles incendios, no bloquee las tomas de aire ni el conducto de escape
de ninguna manera. No haga funcionar el calefactor sobre supercies blandas, como
una cama, donde las aberturas puedan bloquearse.
10. El calefactor contiene piezas internas que se calientan, forman arcos eléctricos o
generan chispas. No lo use en áreas donde se utilice o se guarde gasolina, pintura o
líquidos inamables.
11. Utilice este calefactor solo como se describe en este manual. Otros usos no
recomendados por el fabricante podrían provocar incendios, choques eléctricos o
lesiones personales.
12. Para desconectar el calentador, apague los controles y apague el circuito del
calentador en el panel de desconexión principal.
13. Si se enciende la luz roja de alarma en la parte frontal de la unidad, apague
inmediatamente el calentador e inspeccione si hay objetos en el calentador o
adyacentes al mismo que puedan haber bloqueado el ujo de aire o haber causado
altas temperaturas. NO OPERE EL CALENTADOR CON LA LUZ DE ALARMA
ILUMINADA.
INSTRUCCIONES IMPORTANTES
GUARDE ESTAS INSTRUCCIONES
Este producto puede exponerlo a usted a agentes químicos incluyendo ftalato de diisononilo
(DINP), reconocido por el estado de California como causante de cáncer, así como ftalatos de
diisodecilo (DIDP), reconocidos por el estado de California como causantes de defectos congénitos
y otros daños al sistema reproductor.
Para obtener más información, visite www.p65Warnings.ca.gov
ADVERTENCIA
19
ARTÍCULO PÁGINA
ESPECIFICACIONES ..................................................................... 19
INFORMACIÓN GENERAL SOBRE SEGURIDAD ......................... 19
UBICACIÓN DEL CALEFACTOR .................................................... 20
PRE-INSTALACIÓN ........................................................................ 21
INSTALACIÓN ................................................................................. 22
INSTRUCCIONES DE USO ............................................................ 26
MANTENIMIENTO Y LIMPIEZA ..................................................... 28
PIEZAS DE REPUESTO ................................................................. 28
SOLUCIÓN DE PROBLEMAS ........................................................ 29
1.Utilicesolocablesdecobrecalicadospara60°Ccomomínimo.
2.Elujodeairedelcalefactorsedebeorientardemodoquequedeparaleloala
pared adyacente o en dirección contraria a ella.
3.Respetelosrequisitosdeespaciolibrehacialapared,elpisoyeltecho.
4.Todoelcableadosedeberealizardeconformidadconloscódigosnacionalesy
localesdeelectricidaddeEstadosUnidosyelcalefactordebeestarconectado
atierracomoprecaucióncontraposibleschoqueseléctricos.Elcircuitodel
calefactorsedebeprotegerconfusiblesapropiados.
5.Laestructurademontajeylatornilleríadeanclajedebenpodersoportardemodo
conableelpesodelcalefactorydelsoportedemontaje,siseloutiliza.
Índice Amperios BTU/hora
10000W II 240-1-60 41.66 34120
7500W I 240-1-60 31.25 22589
CONTENIDO
ESPECIFICACIONES
INFORMACIÓN SOBRE SEGURIDAD
ESTECALEFACTORREQUIEREUNAINSTALACIÓNCABLEADAFIJA(SINENCHUFE).ALA
INSTALACIÓN LA DEBE REALIZAR UN ELECTRICISTA CERTIFICADO Y SE DEBE EFECTUAR
DE CONFORMIDAD CON TODOS LOS CÓDIGOS LOCALES Y NACIONALES DE ELECTRICIDAD.
NOTA: COMPATIBLE CON UN TERMOSTATO DE PARED BIPOLAR CON TENSIÓN DE LÍNEA DE
240 V. DEBE SER INSTALADO POR UN ELECTRICISTA CERTIFICADO.
LEAYCOMPRENDATODASLASINSTRUCCIONESDEINSTALACIÓNYFUNCIONAMIENTO,Y
RESPETE TODAS LAS INSTRUCCIONES DE SEGURIDAD.
ADVERTENCIA
20
DISTANCIA
MÍNIMA
A PARED
DISTANCIA
MÍNIMA
A PARED
13 pulg.
VISTA LATERAL
10-⁄ pulg.
24 pulg.
4½ pulg.
¾ pulg.
1¾ pulg.
½ pulg.
7-3/8 pulg.
4½ pulg.
DISTANCIA
MÍNIMA
DESDE LA
DESCARGA A
UN OBJETO
DISTANCIA
MÍNIMA AL PISO
8 pies
ALTURA MÁXIMA DE MONTAJE DESDE:
Unidad para proporcionar aire vertical = 11 pies
Unidad para proporcionar aire horizontal = 8 pies
Nota: El espacio libre
mínimo al techo cuando no
se utilizan los soportes de
montaje es de 1-⁄ pulg.
14 pulg.
12½ pulg.
VISTA FRONTAL Figura 2
6.Sedebedesconectarlaalimentacióneléctricaybloquearlacajadeservicio
eléctricoantesdeinspeccionarelcalefactor,limpiarloorealizarlemantenimiento.
Estaesunaprecauciónparaevitarchoqueseléctricosgraves.
7.Estecalefactornoesapropiadoparautilizarloenubicacionespeligrosastalcomo
lasdenelaAsociaciónNacionaldeProteccióncontraIncendios(NFPA,porsu
siglaeninglés)deEstadosUnidos.Elcalefactorcontienepiezasinternasquese
calientan,formanarcoseléctricosogeneranchispas.Nolouseenáreasdonde
seutiliceoseguardegasolina,pinturaolíquidosinamables.
8.Estecalefactornoesapropiadoparautilizarloenatmósferascorrosivas,como
zonasmarinas,invernaderosoáreasdealmacenamientodeproductosquímicos.
9.Estecalefactordebeestarubicadoa8piesdelpiso,comomínimo.
Instaleelcalefactorfueradelaszonasdetránsitoymantengalosespacioslibres
indicadosenlagura2.Ladireccióndelujodeairenodebeestarrestringidapor
columnasomáquinas.Elujodeairesolodeberozarlasparedesynodirigirse
directamenteaellas.Cuandoseutilizamásdeuncalefactorenunárea,los
calefactoressedebendisponerdemodoqueladescargadeairedecadauno
acompañeelujodeairedelosotrosparaproporcionarunacirculaciónóptimade
airecaliente,comoseindicaenlagura3.
INSTALAR INCORRECTAMENTE O NO RESPETAR LOS PROCEDIMIENTOS DESCRITOS EN
ESTE MANUAL DE INSTRUCCIONES PUEDE DAR LUGAR A CHOQUES ELÉCTRICOS GRAVES.
ADVERTENCIA
INFORMACIÓN SOBRE SEGURIDAD
UBICACIÓN DEL CALEFACTOR
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Dyna Glo EG10000DH Le manuel du propriétaire

Catégorie
Chauffe-eau
Taper
Le manuel du propriétaire