Multitech MTCDT-L4N1-247A-915-US Mode d'emploi

Taper
Mode d'emploi
Conduit
®
Cat 4 for North
America
MTCDT-L4N1 Hardware Guide
CONDUIT CAT 4 FOR NORTH AMERICA
2 Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide
Conduit Cat 4 for North America
Model: MTCDT-L4N1
Part Number: S000733
Copyright
This publication may not be reproduced, in whole or in part, without the specific and express prior written permission signed by an executive officer of
Multi-Tech Systems, Inc. All rights reserved. Copyright © 2019 by Multi-Tech Systems, Inc.
Multi-Tech Systems, Inc. makes no representations or warranties, whether express, implied or by estoppels, with respect to the content, information,
material and recommendations herein and specifically disclaims any implied warranties of merchantability, fitness for any particular purpose and non-
infringement.
Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of
Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.
Legal Notices
The MultiTech products are not designed, manufactured or intended for use, and should not be used, or sold or re-sold for use, in connection with
applications requiring fail-safe performance or in applications where the failure of the products would reasonably be expected to result in personal injury or
death, significant property damage, or serious physical or environmental damage. Examples of such use include life support machines or other life
preserving medical devices or systems, air traffic control or aircraft navigation or communications systems, control equipment for nuclear facilities, or
missile, nuclear, biological or chemical weapons or other military applications (“Restricted Applications”). Use of the products in such Restricted
Applications is at the user’s sole risk and liability.
MULTITECH DOES NOT WARRANT THAT THE TRANSMISSION OF DATA BY A PRODUCT OVER A CELLULAR COMMUNICATIONS NETWORK WILL BE
UNINTERRUPTED, TIMELY, SECURE OR ERROR FREE, NOR DOES MULTITECH WARRANT ANY CONNECTION OR ACCESSIBILITY TO ANY CELLULAR
COMMUNICATIONS NETWORK. MULTITECH WILL HAVE NO LIABILITY FOR ANY LOSSES, DAMAGES, OBLIGATIONS, PENALTIES, DEFICIENCIES, LIABILITIES,
COSTS OR EXPENSES (INCLUDING WITHOUT LIMITATION REASONABLE ATTORNEYS FEES) RELATED TO TEMPORARY INABILITY TO ACCESS A CELLULAR
COMMUNICATIONS NETWORK USING THE PRODUCTS.
The MultiTech products and the final application of the MultiTech products should be thoroughly tested to ensure the functionality of the MultiTech
products as used in the final application. The designer, manufacturer and reseller has the sole responsibility of ensuring that any end user product into
which the MultiTech product is integrated operates as intended and meets its requirements or the requirements of its direct or indirect customers.
MultiTech has no responsibility whatsoever for the integration, configuration, testing, validation, verification, installation, upgrade, support or maintenance
of such end user product, or for any liabilities, damages, costs or expenses associated therewith, except to the extent agreed upon in a signed written
document. To the extent MultiTech provides any comments or suggested changes related to the application of its products, such comments or suggested
changes is performed only as a courtesy and without any representation or warranty whatsoever.
Contacting MultiTech
Knowledge Base
The Knowledge Base provides immediate access to support information and resolutions for all MultiTech products. Visit http://www.multitech.com/kb.go.
Support Portal
To create an account and submit a support case directly to our technical support team, visit: https://support.multitech.com.
Support
Business Hours: M-F, 8am to 5pm CT
Country By Email By Phone
Europe, Middle East, Africa: [email protected] +(44) 118 959 7774
U.S., Canada, all others: [email protected] (800) 972-2439 or (763) 717-5863
Warranty
To read the warranty statement for your product, visit https://www.multitech.com/legal/warranty. For other warranty options, visit
www.multitech.com/es.go.
World Headquarters
Multi-Tech Systems, Inc.
2205 Woodale Drive, Mounds View, MN 55112
Phone: (800) 328-9717 or (763) 785-3500
Fax (763) 785-9874
CONTENTS
Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide 3
Contents
Chapter 1 Product Overview ................................................................................................................................. 5
Introduction .................................................................................................................................................................. 5
Documentation ............................................................................................................................................................. 5
Product Kit Contents..................................................................................................................................................... 6
Product Build Options ................................................................................................................................................... 6
Chapter 2 Specifications........................................................................................................................................ 8
MTCDT-L4N1 Specifications .......................................................................................................................................... 8
Dimensions.................................................................................................................................................................. 10
Backpanel Connectors ................................................................................................................................................ 11
LED Descriptions ......................................................................................................................................................... 12
Chapter 3 Power Draw ........................................................................................................................................ 14
Power Draw................................................................................................................................................................. 14
MTCDT-L4N1 with Modem and No Accessory Cards................................................................................................ 14
Chapter 4 Antenna Information .......................................................................................................................... 15
Wieson Antenna.......................................................................................................................................................... 15
Antenna Specifications ............................................................................................................................................. 15
Chapter 5 Setting up and Configuring the Device ................................................................................................ 16
Install and Connect Conduit Hardware....................................................................................................................... 16
Installing a Mini SIM Card ........................................................................................................................................... 16
Accessory Port (mCard) Interfaces.............................................................................................................................. 17
Installing a Micro SD Card........................................................................................................................................... 18
Installing a Battery ...................................................................................................................................................... 18
Connecting to the Debug Interface............................................................................................................................. 19
Restoring User Defined Settings ................................................................................................................................. 20
Resetting the Device ................................................................................................................................................... 20
Powering Up the device.............................................................................................................................................. 20
Dual Carrier Firmware for Cellular Radio.................................................................................................................... 21
Chapter 6 Regulatory & Safety Information ........................................................................................................ 22
47 CFR Part 15 Regulation Class B Devices ................................................................................................................. 22
FCC Interference Notice.............................................................................................................................................. 22
FCC Notice................................................................................................................................................................... 22
MTSMC-L4N1 and MTSMC-L4N1-U ............................................................................................................................ 23
FCC Parts 22H, 24E, 27, and 90................................................................................................................................. 23
Industry Canada Class B Notice................................................................................................................................... 24
Lithium Battery ........................................................................................................................................................... 25
User Responsibility...................................................................................................................................................... 25
Power Supply Caution................................................................................................................................................. 25
CONTENTS
4 Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide
Device Maintenance ................................................................................................................................................... 25
Vehicle Safety.............................................................................................................................................................. 26
Notice regarding Compliance with FCC, EU, and Industry Canada Requirements for RF Exposure........................... 26
Radio Frequency (RF) Safety ....................................................................................................................................... 26
Sécurité relative aux appareils à radiofréquence (RF)................................................................................................ 27
Interference with Pacemakers and Other Medical Devices ...................................................................................... 27
Potential interference............................................................................................................................................... 27
Precautions for pacemaker wearers ........................................................................................................................ 27
Chapter 7 Environmental Notices........................................................................................................................ 29
Waste Electrical and Electronic Equipment Statement .............................................................................................. 29
WEEE Directive.......................................................................................................................................................... 29
Instructions for Disposal of WEEE by Users in the European Union ........................................................................ 29
Restriction of the Use of Hazardous Substances (RoHS) ............................................................................................ 29
REACH Statement ....................................................................................................................................................... 30
Registration of Substances........................................................................................................................................ 30
Information on HS/TS Substances According to Chinese Standards (in Chinese) ...................................................... 31
Information on HS/TS Substances According to Chinese Standards ......................................................................... 32
PRODUCT OVERVIEW
Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide 5
Chapter 1 Product Overview
Introduction
Conduit
®
is a programmable gateway that uses an open Linux development environment to enable machine-to-
machine (M2M) connectivity using various wireless interfaces. It also provides an online application store for
industrial things as a platform for developers to provision and manage their gateway and associated sensors and
devices.
Documentation
The following documentation is available at https://www.multitech.com/brands/multiconnect-conduit.
Document Description Part Number
Hardware Guide This document provides overview, safety and regulatory
information, design considerations, schematics, and general
hardware information.
S000733
Software Guide This document provides instructions and information on how
to properly configure your device through its user interface.
S000727
API Developer Guide You can use the Conduit API to manage configurations, poll
statistics, and issue commands. Documentation is available on
the MultiTech Developer Resources website at:
http://www.multitech.net/developer/software/aep/conduit-
aep-api/.
N/A
Telit LE910C4-NF AT
Commands Reference Guide
Lists AT Commands and parameters used to configure your
device. (Applies to L4E1 and L4N1 - Cat 4 devices)
80502ST10950A
PRODUCT OVERVIEW
6 Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide
Product Kit Contents
Your Product Kit includes the following (varies with model):
Device 1 - MTCDT-Conduit
Power Supply 1 - 100-240V 9V-1.7A power supply with removable
blades
1 - NAM blade/plug
Cables 1 - Micro USB Cable
1 - Ethernet Cable RJ45 6-ft.
Antennas* 2 - LTE SMA (for Conduit LTE only), 1 - GPS antenna, and
1 - Wi-Fi/Bluetooth antenna
Customer Notices Quick Start*
Registration Card
Feet 4 - Clear Adhesive Feet
Additional 1 - Promotional screwdriver
Note: *HEPTA or LTE antennas are not included with MTCDT-246 or 247A/L (No Radio versions).
Note: GNSS or WiFi/Bluetooth antennas are not included with MTCDT-240 A/L.
Product Build Options
Product Description Region
MTCDT-L4N1-240A-US LTE Category 4 mPower Programmable Gateway w/ US Accessory Kit
(AT&T/Verizon)
US/Canada
MTCDT-L4N1-240L-US LTE Category 4 mLinux Programmable Gateway w/ US Accessory Kit
(AT&T/Verizon)
US/Canada
MTCDT-L4N1-246A-915-US LTE Category 4 mPower Programmable Gateway 8-channel, 915 MHz,
GNSS w/ US Accessory Kit (AT&T/Verizon)
US/Canada
MTCDT-L4N1-246A-US LTE Category 4 mPower Programmable Gateway, GNSS w/ US
Accessory Kit (AT&T/Verizon)
US/Canada
MTCDT-L4N1-246L-915-US LTE Category 4 mLinux Programmable Gateway 8-channel, 915 MHz,
GNSS w/ US Accessory Kit (AT&T/Verizon)
US/Canada
MTCDT-L4N1-246L-US LTE Category 4 mLinux Programmable Gateway, GNSS w/ US
Accessory Kit (AT&T/Verizon)
US/Canada
MTCDT-L4N1-247A LTE Category 4 mPower Programmable Gateway, GNSS+WiFi/BT
(AT&T/Verizon)
US/Canada
MTCDT-L4N1-247A-915-US LTE Category 4 mPower Programmable Gateway 8-channel, 915 MHz,
GNSS+WiFi/BT w/ US Accessory Kit (AT&T/Verizon)
US/Canada
MTCDT-L4N1-247A-US LTE Category 4 mPower Programmable Gateway, GNSS+WiFi/BT w/
US Accessory Kit (AT&T/Verizon)
US/Canada
PRODUCT OVERVIEW
Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide 7
Product Description Region
MTCDT-L4N1-247L-US LTE Category 4 mLinux Programmable Gateway, GNSS+WiFi/BT w/ US
Accessory Kit (AT&T/Verizon)
US/Canada
MTCDT-L4N1-246A-
STARTERKIT-915
LTE Category 4 Conduit IoT Starter Kit for LoRa Technology, 8-channel,
915 MHz w/ GNSS (AT&T/Verizon)
US/Canada
MTCDT-L4N1-247A-
STARTERKIT-915
LTE Category 4 Conduit IoT Starter Kit for LoRa Technology, 8-channel,
915 MHz w/ GNSS+Wi-Fi/BT (AT&T/Verizon)
US/Canada
Note:
The complete product code may end in .Rx. For example, MTCDT-L4N1.Rx, where R is revision and x is the
revision number.
SPECIFICATIONS
8 Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide
Chapter 2 Specifications
MTCDT-L4N1 Specifications
Category Description
General
Performance LTE FDD Cat. 4, 3GPP release 10
HSPA+ with GPRS fallback
Frequency Bands (MHz) 4G LTE: B2, B4, B5, B12, B13, B14, B66, B71
3G: B2, B4, B5
Cellular radio module Telit LE910C4-NF
Cellular packet data Up to 150 Mbps downlink (Theoretical maximum - actual
performance may be affected by multiple environmental factors.)
Up to 50 Mbps uplink (See above note.)
Diversity/MIMO Rx Diversity and MIMO DL 2x2
SMS over IMS Point-to-Point messaging, Mobile terminated SMS, Mobile originated
SMS
Physical Description
Dimensions See the drawing in Dimensions.
Weight 15.6 oz. (442.25 grams) with no accessory cards installed
Connectors
Connectors 1 USB device micro Type B debug port
1 RJ-45 Ethernet port
1 USB 2.0 port
2 cellular antenna connectors
1 Wi-Fi/Bluetooth connector
1 GPS antenna connector
Power Requirements
Input Voltage 9-32 Volts
Power Draw See Conduit Power Draw
Environment
Operating Environment -30° to +70° C
1
Storage Environment -40° to +85° C
Relative Humidity 20 to 90% non-condensing
Certifications
SPECIFICATIONS
Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide 9
Category Description
Radio & EMC Compliance FCC Part 15 Class B/IC Class B
Safety Compliance UL 60950-1 2nd Ed.
Telecom Approvals AT&T / Verizon
1
UL Listed @ 40° C, limited by AC power supply. UL Recognized @ 65° C for Conduit LTE devices when used with
the fused DC power cable, part number FPC-532-DC.
Installation in outdoor locations or ambient above 70° C has not been evaluated by UL. UL Certification does not
apply or extend to use in outdoor applications.
Optional power must be UL Listed ITE power supply marked LPS or Class 2 rated 9 to 32 VDC, 5A. Certification does
not apply or extend to Voltages outside certified range, and has not been evaluated by UL for operating voltages
beyond tested range.
SPECIFICATIONS
10 Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide
Dimensions
SPECIFICATIONS
Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide 11
Backpanel Connectors
Label Description
CELL, AUX Cellular antenna inputs.
CELL - Primary.
AUX - Diversity.
AP1, AP2 Slots for MultiTech accessory cards. You can install an accessory card in either slot. Both slots
can be occupied at one time. An exception is an SDIO (Secure Digital Input/Output) card,
which can be used only in the AP1 slot. Your device may ship with one or more accessory
cards pre-installed.
USB DEVICE User-defined, high-speed 480 Mbps, standard USB 2.0 Micro B connector. Use this port to
connect the Conduit to a computer or another device. By default, this port is a serial port
terminal interface, but you can program it to act as another device such as a mass storage
device or an Ethernet port.
E-NET RJ-45 receptacle for standard Ethernet 10/100 Base-T.
Caution: Ethernet ports and command ports are not designed to be connected to a public
telecommunication network or used outside the building or campus.
USB HOST High-speed, standard USB 2.0 Type A connector. 500mA maximum current draw. You can
plug into the Host port a device such as a flash drive, camera, or printer if the Linux kernel
has the appropriate driver.
Power 9-32 Vdc power receptacle for provided power cord.
GPS GPS antenna input. (Availability based on model.)
WIFI Wi-Fi antenna input for 2.4/5.0 GHz antenna. (Availability based on model.)
SPECIFICATIONS
12 Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide
LED Descriptions
Conduit mLinux Model Front Panel
Conduit mPower Model Front Panel
Label Name Description
PWR Power Solid (constant) green if unit is on indicating that DC power is present.
STATUS Power Status Default condition: LED blinks when mLinux is fully loaded.
LS Link Status Varies with radio model.
A-B-C-D -- These 4 LEDs are user-specified. Present on the Conduit mLinux model only.
CD Carrier Detect This LED is on when a cellular data connection is made. Present on the
Conduit mPower model only.
SPECIFICATIONS
Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide 13
Label Name Description
Signal Signal Strength These 3 LEDs display the strength of the cellular signal. Present on the
Conduit mPower model only.
If a cellular radio is installed, the typical LS (Link Status) LED behavior is the following:
OFF - No power to the cellular radio
Continuously Lit - Not registered
Slow Blink (-0.2Hz) - Registered or connected
On the back of the Conduit, the RJ-45 Ethernet LEDs (located at the bottom of the connector) are defined as
follows:
Orange LED (lower-left) indicated activity/link. Blinks when there is transmit and receive on the
Ethernet link. It shows a steady light when there is a valid Ethernet connection.
Green LED (lower-right) indicates link speed. Lit when Ethernet is linked at 100Mbps. If not lit, Ethernet
is linked at 10 Mbps.
POWER DRAW
14 Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide
Chapter 3 Power Draw
Power Draw
MTCDT-L4N1 with Modem and No Accessory Cards
Radio Protocol Sleep Mode
Current
Cellular Call
Box
Connection No
Data (mA)
Average
Measured
Current at
Max Power
(mA)
1
TX Pulse (Avg)
Amplitude
Current
Total Inrush
Charge
Measured in
MilliCoulombs
(mC)
2
Total Inrush
Charge
Duration
during
Powerup
(Inrush
Duration)(mS)
9.0 Volts
WCDMA 1854
Mhz WS46=22
NA 165 635 728 4.87 9.49
LTE freq Band
14 793 Mhz
NA 163 617 704 4.87 9.49
12.0 Volts
WCDMA 1854
Mhz WS46=22
NA 136 488 572 4.46 8.44
LTE freq Band
14 793 Mhz
NA 136 478 564 4.46 8.44
24.0 volts
WCDMA 1854
Mhz WS46=22
NA 93 276 356 4.03 17.5
LTE freq Band
14 793 Mhz
NA 90 274 332 4.03 17.5
1
Max Power: The continuous current during maximum data rate with the radio transmitter at maximum power.
2
Total Inrush Charge: The total inrush charge at power on expressed in Millicoulombs (mC).
Note:
Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into the power source when
determining product load.
ANTENNA INFORMATION
Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide 15
Chapter 4 Antenna Information
Wieson Antenna
Devices were approved with the following antenna:
Manufacturer: Wieson
Description: LTE GY115HT467-017
Model Number: 11320Y11194A1
MultiTech ordering information:
Model Quantity
ANLTE2-2HRA 1
ANLTE2-10HRA 10
ANLTE2-50HRA 50
Antenna Specifications
Category Description
Frequency Range .069~0.96GHz, 1.71~2.17GHz, 2.3GHz~2.69GHz
Impedance 50 Ohms
VSWR VSWR should not exceed 3:1 at any point across the bands of operation
Peak Gain 3.8 dBi
Radiation Omni-directional
Polarization Linear Vertical
SETTING UP AND CONFIGURING THE DEVICE
16 Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide
Chapter 5 Setting up and Configuring the Device
Install and Connect Conduit Hardware
To install and cable the device:
1. Install a Mini SIM card.
2. Install a Micro SD card (optional).
3. Install a battery (optional).
4. Connect the supplied antenna to the CELL connector on the back of the device.
5. Use the Ethernet connector to connect the Conduit to the device used to administer the Conduit.
6. Install any mCard accessory cards into a slot at the back of the device. Refer to Installing an mCard
Accessory Card for instructions.
7. Depending on the accessory card type, attach any antennas or cables for use with the card.
8. Connect the power cord to an outlet or power strip and to the power adapter.
9. Connect the power adapter to the barrel jack on the back panel of the device. The Power LED comes on
immediately after power is applied. Wait for the Status LED to begin blinking.
Installing a Mini SIM Card
You need:
Phillips screwdriver
Mini SIM card (2FF form factor)
To install or replace the SIM card:
1. Disconnect power to the Conduit, if it is connected.
2. At the front of the Conduit housing, remove the screw that secures the nameplate to the housing and
remove the nameplate.
3. Locate the SIM card holder in the upper right corner of the opening. If a SIM card is installed and needs to
be removed, slide it out of the SIM card holder.
4. Gently push the new SIM card into SIM card holder face up with the cut corner to the right and the SIM
contacts facing toward the Conduit’s interior.
5. If not installing a battery or micro SD card, reattach the MultiTech nameplate to the Conduit using the
screw removed in Step 2.
SETTING UP AND CONFIGURING THE DEVICE
Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide 17
Accessory Port (mCard) Interfaces
The accessory card interface on the Conduit base board has the following interface options:
Interface Description
I2C Used by all accessory cards. I2C is required for
Electronic Identification (EID) support on the accessory
card but can be used for other I2C devices. It should
supports standard (100 kHz) and/or fast (400 kHz) clock
speeds.
The I2C interface reserves the full block of EEPROM
address space for Electronic ID support, so we
recommend that you not attach any other EEPROM
devices to the interface. We recommend that you use a
24C04 part, because both address bits of the 24C04 are
connected to the AP interface allowing you to identify
four separate accessory port (AP) cards in a system.
Serial UART Serial UART with HW flow control used by Serial
inteface based Accessory Cards
SDIO interface and/or SPI Interface AP1 has option for SDIO or SPI interface, based on what
Accessory Card is installed. AP2 supports only SPI based
Accessory Cards.
GPIO Additional control pins for certain Accessory Cards.
Interrupts Software defined interrupts. Can also be used as
additional control pins.
PPS GPS generated Pulse-Per-Second signal used for
software timing. Default is 1 pulse/sec.
USB 2.0 A standard USB 2.0 High Speed interface for USB based
Accessory Cards.
5 VDC 1 Amp supply Used by all accessory cards.
3.3 VDC 1 Amp supply Used by all accessory cards.
SETTING UP AND CONFIGURING THE DEVICE
18 Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide
For accessory card specifications, regulatory content, and installation information, see the Accessory Card
information.
Installing a Micro SD Card
You need:
Phillips screwdriver
MicroSD memory card
To install or replace the SD card:
1. Disconnect power to the Conduit, if it is connected.
2. At the front of the Conduit, remove the screw that secures the MultiTech nameplate.
3. Locate the SD card at the left side of the opening on the underside of the PC board.
4. If an SD card is already installed, gently push on the card to release it from its setting and remove it from
the housing with your fingers.
5. With the new SD card contacts facing up and toward the interior of the device, gently push the card into
the slot to secure it.
6. Reattach the MultiTech nameplate to the housing using the screw removed in step 2.
Installing a Battery
The battery is located in the Conduit housing.
You need:
Phillips screwdriver
If replacing a battery, non-metal tweezers or similar object
CR1632 standard coin lithium battery
To install or replace the battery:
1. If connected, disconnect power to the Conduit.
2. At the front of the Conduit housing, remove the screw that secures the MultiTech nameplate to the
housing.
SETTING UP AND CONFIGURING THE DEVICE
Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide 19
3. The battery holder is located at the right side of the opening on the underside of the PC board. To
remove an existing battery, use non-metal tweezers as necessary.
4. Orient the new battery so that the positive (+) pole is facing down. Use your fingers or non-metal
tweezers to insert the battery into the holder.
5. Reattach the MultiTech nameplate to the housing using the screw removed in Step 2.
CAUTION: Risk of explosion if this battery is replaced by an incorrect type. Dispose of batteries according to
instructions.
Note:
ATTENTION: Risque d’explosion si vous remplacez la batterie par un modèle incompatible. Jetez
les piles usagées selon les instructions.
Connecting to the Debug Interface
You need:
Phillips screwdriver
Standard USB Micro B cable
To connect the debug cable:
1. Disconnect power to the Conduit, if it is connected.
2. At the front of the Conduit housing, remove the screw that secures the MultiTech nameplate to the
housing.
3. Locate the USB debug cable connector in the center of the opening.
4. Connect the USB Micro B cable to the debug connector.
5. Connect the Type A end of the USB cable to the host.
6. From the host, use an application such as TeraTerm with a baud rate of 115,200. If the USB driver does
not automatically install, do the following:
a. Unplug the USB cable.
b. Go to the following web site to download and install the appropriate USB driver:
https://www.maxlinear.com/support/design-tools/software-drivers
c. Plug the USB cable back into the housing.
7. From the host, access the Conduit's USB COM port.
SETTING UP AND CONFIGURING THE DEVICE
20 Conduit
®
Cat 4 for North America MTCDT-L4N1 Hardware Guide
Restoring User Defined Settings
You need:
A pin, paperclip, or similar thin object that can fit into the reset hole.
To restore user defined settings for an mPower device:
1. Locate the hole in the panel labeled RESET. The reset button is recessed into the housing.
2. Use the pin to press in the button for between 3 to 29 seconds, then release the reset button.
If you do not press in the button long enough, the device will reset, but the user defined settings
will not be restored.
If you hold it too long (30 seconds or longer), factory default settings will be restored.
Note: The RESET button is in the same location on all Conduit models.
Resetting the Device
You need:
A pin, paperclip, or similar thin object that can fit into the reset hole.
The following is the default condition for the RESET button on the Conduit. You can program a change to the
behavior of the button if needed.
To reset the device:
1. Find the hole in the front panel labeled RESET. The reset button is recessed into the case.
2. For mPower models: Use the pin to press the RESET button for less than 3 seconds, then release. The
device reboots.
For mLinux models: Press and hold the RESET button for less than 5 seconds, then release. Holding it
beyond 5 seconds resets an mLinux device to factory defaults.
3. The status LED will keep blinking normally for a couple of seconds until the unit resets. Then the status
light will stay solid while the device reboots. Once finished, the status will resume blinking normally.
Powering Up the device
CAUTION: Use only the power cord provided with the device. Using any other power cord voids the warranty
and can damage the device.
To power up the device:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Multitech MTCDT-L4N1-247A-915-US Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues