Hypertherm Powermax45 XP Field Service Bulletin

Taper
Field Service Bulletin
Field Service Bulletin
Bulletin de service sur le terrain
805950 Revision 3 December 2016
Révision 3 – Decembre 2016
Powermax45
®
Powermax45 XP Capacitor
Replacement Kit
Kit de remplacement du
condensateur du Powermax45
Powermax45 XP
Hypertherm Inc.
Etna Road, P.O. Box 5010
Hanover, NH 03755 USA
603-643-3441 Tel (Main Office)
603-643-5352 Fax (All Departments)
[email protected] (Main Office Email)
800-643-9878 Tel (Technical Service)
[email protected] (Technical Service Email)
800-737-2978 Tel (Customer Service)
customer.service@hypertherm.com (Customer Service Email)
866-643-7711 Tel (Return Materials Authorization)
877-371-2876 Fax (Return Materials Authorization)
[email protected] (RMA email)
Hypertherm México, S.A. de C.V.
Avenida Toluca No. 444, Anexo 1,
Colonia Olivar de los Padres
Delegación Álvaro Obregón
México, D.F. C.P. 01780
52 55 5681 8109 Tel
52 55 5683 2127 Fax
Soporte.Tecnico@hypertherm.com (Technical Service Email)
Hypertherm Plasmatechnik GmbH
Sophie-Scholl-Platz 5
63452 Hanau
Germany
00 800 33 24 97 37 Tel
00 800 49 73 73 29 Fax
31 (0) 165 596900 Tel (Technical Service)
00 800 4973 7843 Tel (Technical Service)
[email protected] (Technical Service Email)
Hypertherm (Singapore) Pte Ltd.
82 Genting Lane
Media Centre
Annexe Block #A01-01
Singapore 349567, Republic of Singapore
65 6841 2489 Tel
65 6841 2490 Fax
[email protected] (Marketing Email)
TechSupportAP[email protected] (Technical Service Email)
Hypertherm Japan Ltd.
Level 9, Edobori Center Building
2-1-1 Edobori, Nishi-ku
Osaka 550-0002 Japan
81 6 6225 1183 Tel
81 6 6225 1184 Fax
HT[email protected] (Main Office Email)
TechSupportAP[email protected] (Technical Service Email)
Hypertherm Europe B.V.
Vaartveld 9, 4704 SE
Roosendaal, Nederland
31 165 596907 Tel
31 165 596901 Fax
31 165 596908 Tel (Marketing)
31 (0) 165 596900 Tel (Technical Service)
00 800 4973 7843 Tel (Technical Service)
(Technical Service Email)
Hypertherm (Shanghai) Trading Co., Ltd.
B301, 495 ShangZhong Road
Shanghai, 200231
PR China
86-21-80231122 Tel
86-21-80231120 Fax
86-21-80231128 Tel (Technical Service)
(Technical Service Email)
South America & Central America: Hypertherm Brasil Ltda.
Rua Bras Cubas, 231 – Jardim Maia
Guarulhos, SP – Brasil
CEP 07115-030
55 11 2409 2636 Tel
[email protected] (Technical Service Email)
Hypertherm Korea Branch
#3904. APEC-ro 17. Heaundae-gu. Busan.
Korea 48060
82 (0)51 747 0358 Tel
82 (0)51 701 0358 Fax
[email protected] (Marketing Email)
TechSupportAP[email protected]
(Technical Service Email)
Hypertherm Pty Limited
GPO Box 4836
Sydney NSW 2001, Australia
61 (0) 437 606 995 Tel
61 7 3219 9010 Fax
[email protected] (Main Office Email)
TechSupportAP[email protected]
(Technical Service Email)
Hypertherm (India) Thermal Cutting Pvt. Ltd
A-18 / B-1 Extension,
Mohan Co-Operative Industrial Estate,
Mathura Road, New Delhi 110044, India
91-11-40521201/ 2/ 3 Tel
91-11 40521204 Fax
HTIndia.info@hypertherm.com (Main Office Email)
TechSupportAP[email protected]
(Technical Service Email)
© 2016 Hypertherm, Inc. All rights reserved. Tous droits réservés.
Powermax and Hypertherm are trademarks of Hypertherm Inc. and may be registered in the United States and/or other countries. All other trademarks
are the property of their respective holders.
Powermax et Hypertherm sont des marques d’Hypertherm Inc. qui peuvent être déposées aux États-Unis et/ou dans d’autres pays. Toutes les autres
marques commerciales sont la propriété de leurs détenteurs respectifs.
Powermax45/45 XP Field Service Bulletin 805950 1
Powermax45/45 XP Capacitor Replacement Kit
Introduction
Purpose
This field service bulletin describes the steps necessary to replace the capacitors in the Powermax45.
Powermax45 XP systems: Complete instructions for installing this kit are included in the Powermax45 XP Service
Manual (809230). To download the manual, go to www.hypertherm.com/docs
.
Tools and materials needed
Assorted Phillips
®
and TORX
®
screwdrivers
Needlenose pliers
228301 Kit contents (200–240 V CSA and 230 V CE)
228426 Kit contents (400 V CE)
428080 Kit contents (480 V CSA)
DANGER!
ELECTRIC SHOCK CAN KILL
Disconnect electrical power before performing any maintenance. See the
Safety and Compliance Manual (80669C) for more safety precautions.
Part number Description Quantity
075697 Machine screw: M5 x 0.8 x 10 4
109659 Capacitor: 5600UF 250VDC 2
Part number Description Quantity
075697 Machine screw: M5 x 0.8 x 10 4
109673 Capacitor: 2200UF 400VDC 2
Part number Description Quantity
075697 Machine screw: M5 x 0.8 x 10 4
209197 Capacitor: 1800UF 450VDC 2
2 Powermax45/45 XP Field Service Bulletin 805950
Powermax45/45 XP Capacitor Replacement Kit
Replace the capacitors
1. Turn OFF the power, disconnect the power cord, and disconnect the gas supply.
2. Remove the 2 screws from the handle on the top of the power supply. Tip the end panels back slightly so that you
can get the edges of the handle out from underneath them. Lift the cover off the power supply. Remove the
component barrier that protects the power board.
3. Remove the 4 capacitor machine screws. Discard the screws.
Figure 1 – Capacitor machine screws in the power supply
4. From the top of the power supply, use needlenose pliers to compress and release the top 2 clips on the fan’s plenum.
After you release the top clips, you can tilt the plenum away from the power supply to reach the bottom 2 clips. Lift
the plenum off the fan casing.
5. Slide both capacitors out of their slots in the center panel, away from the power board, and discard the capacitors.
6. Install the 2 new capacitors in their place, making sure their screw holes line up with the holes in the power board.
IMPORTANT: Make sure the rubber vent holes on the capacitor tops are facing down, and line up with
the vent holes in the power board.
CAUTION!
Static electricity can damage circuit boards. Use proper precautions when handling printed circuit
boards.
– Store PC boards in anti-static containers.
– Wear a grounded wrist strap when handling PC boards.
TP 19
W
-
+
-
+
TP 18
R
TP 17
B
192 VDC
192 VDC
Black wire
Machine screws (4)
Powermax45/45 XP Field Service Bulletin 805950 3
Powermax45/45 XP Capacitor Replacement Kit
7. Install the 4 new machine screws included in the kit, making sure the black wire is fastened in the correct location.
Figure 2 – Cooling fan side of the power supply
8. Orient the fan plenum so the wider end is at the bottom, and snap the plenum into place.
9. Replace the component barrier that protects the power board.
10. Replace the power supply cover, and install the handle using the 2 screws removed earlier.
Top clips
Capacitors
Fan plenum
Bottom clips
4 Powermax45/45 XP Field Service Bulletin 805950
Powermax45/45 XP Capacitor Replacement Kit
Powermax45/45 XP Bulletin de service sur le terrain 805950 5
Kit de remplacement du condensateur du Powermax45/45 XP
vM
Introduction
Objet
Ce bulletin de service sur le terrain décrit les étapes nécessaires pour le remplacement des condensateurs
du Powermax45.
Systèmes Powermax45 XP: Les instructions complètes pour l’installation de ce kit sont incluses dans le Manuel
de service du Powermax45 XP (809230). Pour télécharger ce manuel, se rendre sur www.hypertherm.com/docs
.
Outils et matériel requis
Tournevis Phillips
®
et TORX
®
assortis.
Pinces à long bec
Contenu du kit 228301 (200 – 240 V CSA et 230 V CE)
Contenu du kit 228426 (400 V CE)
Contenu du kit 428080 (480 V CSA)
DANGER !
UN CHOC ÉLECTRIQUE PEUT ÊTRE MORTEL
Avant tout entretien, débrancher l’alimentation électrique. Se reporter
au Manuel (80669C) de sécurité et de conformité pour des mesures
de sécurité supplémentaires.
Numéro de référence Description Quantité
075697 Vis mécanique : M5 x 0,8 x 10 4
109659 Condensateur : 5600 uF 250 V c.c. 2
Numéro de référence Description Quantité
075697 Vis mécanique : M5 x 0,8 x 10 4
109673 Condensateur : 2200 uF 400 V c.c. 2
Numéro de référence Description Quantité
075697 Vis mécanique : M5 x 0,8 x 10 4
209197 Condensateur : 1800 uF 450 V c.c. 2
6 Powermax45/45 XP Bulletin de service sur le terrain 805950
Kit de remplacement du condensateur du Powermax45/45 XP
Remplacement des condensateurs
1. Couper l’alimentation (OFF), débrancher le cordon d’alimentation et débrancher l’alimentation en gaz.
2. Déposer les deux vis de la poignée située sur le dessus de la source de courant. Basculer légèrement les panneaux
d’extrémité de façon à en extraire les bords de la poignée d’en dessous. Retirer le couvercle de la source de courant
en le levant. Déposer la barrière de composant qui protège le circuit imprimé d’alimentation.
3. Déposer les quatre vis mécaniques du condensateur. Mettre les vis au rebut.
Figure 3 – Vis mécanique du condensateur dans la source de courant
4. Du haut de la source de courant, compresser et relâcher les deux attaches du dessus sur l’enceinte du ventilateur
à l’aide d’une pince à long bec. Après avoir relâché les attaches supérieures, l’enceinte de la source de courant peut
être dégagée pour accéder aux deux attaches inférieures. Soulever l’enceinte du boîtier de ventilateur.
5. Glisser les deux condensateurs hors de leurs encoches du panneau central, en les éloignant du circuit imprimé
d’alimentation, et les mettre au rebut.
6. Installer les deux nouveaux condensateurs à leur place, en s’assurant que les trous pour les vis sont alignés avec
ceux du circuit imprimé d’alimentation.
ATTENTION !
L’électricité statique peut endommager les cartes de circuits imprimés. Les précautions qui s’imposent
doivent être respectées lors de la manipulation des cartes de circuits imprimés.
– Les cartes de circuits imprimés doivent être rangées dans des contenants antistatiques.
– L’utilisateur doit porter un bracelet antistatique lors de la manipulation des cartes de circuits
imprimés.
TP 19
W
-
+
-
+
TP 18
R
TP 17
B
192 VDC
192 VDC
Fil noir
Vis mécaniques (4)
Powermax45/45 XP Bulletin de service sur le terrain 805950 7
Kit de remplacement du condensateur du Powermax45/45 XP
IMPORTANT : S’assurer que les trous d’évent en caoutchouc du dessus des condensateurs sont dirigés
vers le bas, et alignés avec les trous d’évent du circuit imprimé d’alimentation.
7. Installer les quatre nouvelles vis mécaniques comprises dans le kit en s’assurant que le fil noir est attaché au bon
endroit.
Figure 4 – Côté du ventilateur de refroidissement de la source de courant
8. Orienter l’enceinte du ventilateur de sorte que l’extrémité évasée se trouve en bas et la mettre en place.
9. Replacer la barrière de composant qui protège le circuit imprimé d’alimentation.
10. Remettre en place le couvercle de la source de courant et installer la poignée à l’aide des deux vis retirées
auparavant.
Attaches supérieures
Condensateurs
Enceinte
du ventilateur
Attaches inférieures
8 Powermax45/45 XP Bulletin de service sur le terrain 805950
Kit de remplacement du condensateur du Powermax45/45 XP
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Hypertherm Powermax45 XP Field Service Bulletin

Taper
Field Service Bulletin

dans d''autres langues