Wolf Steel NEFI27H Le manuel du propriétaire

Catégorie
Cheminées
Taper
Le manuel du propriétaire

Ce manuel convient également à

EN
W415-1461 / D / 08.29.18
FR
PG
25
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
INSTALLATION AND
OPERATING INSTRUCTIONS
1.16F
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)720-9081 • www.napoleonfi replaces.com •[email protected]
SAFETY INFORMATION
!
WARNING
If the information in these instructions
are not followed exactly, a fi re may result
causing property damage, personal injury
or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
$10.00
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA C22.2 No-46 / UL 1278
NEFI24H/NEFI27H
ELECTRIC LOGSET INSERT
NEFI24H ILLUSTRATED
EN
W415-1461 / D / 08.29.18
2
NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.
TABLE OF CONTENTS
1.0 INTRODUCTION 3
1.1 DIMENSIONS 4
1.2 LISTING APPROVALS 5
1.3 GENERAL INSTRUCTIONS 5
1.4 RATING PLATE INFORMATION 6
1.5 LABEL LOCATION 6
2.0 LOCATING LOG SET 7
2.1 UNPACKING AND TESTING LOG SET 7
2.2 GROUNDING LOG SET 7
3.0 INSTALLATION 8
3.1 LOG SET INSTALLATION 8
3.1.1 INSTALLING LOG SET INTO EXISTING FIREPLACE 8
3.1.2 INSTALLING LOG SET INTO MANTEL 9
3.2 HARD WIRING INSTALLATION 10
3.3 SECURING THE LOG SET 11
4.0 OPERATING INSTRUCTIONS 12
4.1 OPERATING CONTROL PANEL 12
4.2 OPERATING BY REMOTE CONTROL 13
4.3 REMOTE BATTERY INSTALLATION 13
5.0 FINISHING 14
5.1 NEFI24H LOG PLACEMENT 14
5.2 NEFI27H LOG PLACEMENT 14
5.3 EMBER BED PLACEMENT 15
5.4 CHARCOAL EMBER PLACEMENT 16
6.0 WIRING DIAGRAM 17
7.0 REPLACEMENT PARTS 18
7.1 NEFI24H OVERVIEW 19
7.2 NEFI27H OVERVIEW 20
8.0 TROUBLESHOOTING 21
9.0 WARRANTY 22
10.0 NOTES 23
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your municipality
for recycling instructions.
Les piles doivent être mises au rebut conformément aux lois et à la réglementation locales. Certaines
piles peuvent être recyclées et acceptées dans votre centre de recyclage local. Renseignez-vous auprès
de votre municipalité au sujet des directives de recyclage.
EN
3
1.0
INTRODUCTION
!
WARNING
C
THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF
CONTACTED.
Do not operate appliance before reading and understanding operating instructions. Failure to operate
appliance according to operating instructions could cause fi re or injury.
Risk of burns. Power to the appliance should be turned off and the appliance allowed to cool before
servicing. To disconnect power to the appliance, turn controls to off, then remove plug from outlet.
Do not install damaged, incomplete or substitute components.
Do not burn wood or other materials in this appliance.
Young children should be carefully supervised when they are in the same room as the appliance.
Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier
is recommended if there are at risk individuals in the house. To restrict access to an appliance or stove,
install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the
room and away from hot surfaces.
Clothing or other fl ammable material should not be placed on or near the appliance.
Due to high temperatures, the appliance should be located out of traffi c and away from furniture and
draperies.
Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot
surfaces.
Even after the appliance is out, the glass and/or screen will remain hot for an extended period of time.
Check with your local hearth specialty dealer for safety screens and hearth guards to protect children
from hot surfaces. These screens and guards must be fastened to the fl oor.
Any safety screen or guard removed for servicing must be replaced prior to operating the appliance.
It is imperative that the control compartments, circulating blower and its passageway in the appliance
and are kept clean. The appliance should be inspected before use and at least annually by a qualifi ed
service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding
material, etc. The appliance area must be kept clear and free from combustible materials, gasoline and
other fl ammable vapors and liquids.
Under no circumstances should this appliance be modifi ed.
Do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician
to inspect the appliance and to replace any part of the control system which has been under water.
Do not operate the appliance with the glass door removed, cracked or broken. Replacement of the
glass should be done by a licensed or qualifi ed service person.
Do not strike or slam shut the appliance glass door.
Keep the packaging material out of reach of children and dispose of the material in a safe manner. As
with all plastic bags, these are not toys and should be kept away from children and infants.
Servicing should be done only while the appliance is disconnected from the power supply circuit.
Always unplug appliance when not in use.
Do not operate this appliance with a damaged cord or plug after the appliance malfunctions, has been
dropped or damaged in any manner. Return appliance to authorized service facility for examination,
electrical or mechanical adjustment, or repair.
Do not use outdoors.
Never locate appliance where it may fall into a bathtub or other water container.
Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or the like. Arrange cord
away from traffi c area and where it will not be tripped over.
Connect to properly grounded outlets only.
Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an
electric shock or fi re, or damage the appliance.
To prevent a possible fi re, do not block air intakes or exhaust in any manner. Do not use on soft
surfaces, like a carpet, where openings may become blocked.
Always plug appliances directly into a wall outlet/receptacle. Never use an extension cord or
relocatable power tap (outlet/power strip).
Ensure clearances to combustibles are maintained when building a mantel or shelves above the
appliance. Elevated temperatures on the wall or in the air above the appliance can cause melting,
discolouration or damage to decorations, a T.V. or other electronic components.
W415-1461 / D / 08.29.18
EN
W415-1461 / D / 08.29.18
4
1.1 DIMENSIONS
14"
356mm
24"
610mm
NEFI27H ILLUSTRATED
14"
356mm
NEFI24H ILLUSTRATED
27"
686mm
15 1/2"
393mm
14"
356mm
FRONT VIEW SIDE VIEW
EN
5
4.8B
A.
Prior to plugging your appliance into an electrical outlet, verify that the house circuit breakers for the
outlet are on.
B.
The appliance may emit a slight, harmless odour when fi rst used. This odour is normal and it is caused
by the initial heating of internal appliance elements and will not occur again.
C.
If your appliance does not emit heat, consult the operation section of this manual for further
information.
D.
Use with a CSA- or UL-certifi ed surge protector.
E.
Do not route the power cord directly underneath the appliance.
This electric appliance meets the construction and safety standards of H.U.D. for application in manufactured
homes when installed according to these instructions.
!
WARNING
READ THESE INSTRUCTIONS COMPLETELY BEFORE BEGINNING INSTALLATION. FAILURE TO
FOLLOW THEM COULD CAUSE AN APPLIANCE MALFUNCTION RESULTING IN SERIOUS INJURY
AND/OR PROPERTY DAMAGE.
ALL ELECTRIC APPLIANCES HAVE HOT AND ARCING OR SPARKING PARTS INSIDE. DO NOT USE
IT IN AREAS WHERE GASOLINE, PAINT OR FLAMMABLE LIQUIDS ARE PRESENT.
THIS ELECTRIC APPLIANCE IS TESTED AND LISTED FOR USE ONLY WITH THE OPTIONAL
ACCESSORIES LISTED IN THESE INSTRUCTIONS. USE OF OPTIONAL ACCESSORIES NOT
SPECIFICALLY TESTED FOR THIS ELECTRIC APPLIANCE COULD VOID THE WARRANTY AND/OR
RESULT IN A SAFETY HAZARD.
DO NOT OPEN. RISK OF ELECTRIC SHOCK. NO USER-SERVICEABLE PARTS INSIDE.
DO NOT USE DAMAGED ELECTRICAL CORDS.
SERVICING SHOULD BE DONE ONLY WHILE THE APPLIANCE IS DISCONNECTED FROM THE
POWER SUPPLY CIRCUIT.
TO PREVENT ELECTRIC SHOCK MATCH THE WIDE BLADE OF PLUG TO WIDE SLOT OF
RECEPTACLE AND FULLY INSERT.
1.2 LISTING APPROVALS
This log set has been tested in accordance with the
CSA Standards for fixed and location-dedicated electric
room appliances in the United States and Canada. If
you need assistance during installation, please contact
your local dealer.
NOTE: This log set must be electrically wired and
grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition in the United States or
the Canadian Electric Code, CSA C22.1 in Canada.
Model Number
NEFI24H NEFI27H
Description
24" Electric
Logset Insert
27" Electric
Logset Insert
Voltage
120V AC 120V AC
Watts
Max 1500W Max 1500W
Amps
15 AMP Grounded
Circuit
15 AMP Ground-
ed Circuit
Appliance Width
24" (610mm) 27" (686mm)
Appliance Height
14"
(356mm)
15 1/2" (393mm)
Appliance Depth
14" (356mm) 14" (356mm)
Net Weight
25.4lbs (11.5kg) 29.5lbs (13.4kg)
Gross Weight
35.3lbs (16kg) 40.3lbs (18.3kg)
1.3 GENERAL INSTRUCTIONS
As with most electronic devices, your new log set has been designed to operate at temperatures between
5°C (41°F) and 35° C (95°F). During the colder winter months, allow the log set to reach room temperature
before turning it on.
EN
W415-1461 / D / 08.29.18
6
1.4 RATING PLATE INFORMATION
W385-2026 / A
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARD: CSA 22.2 NO. 46 AND UL 1278 /
HOMOLOGUÉ SELON LES NORMES NATIONALES CANADIENNES ET AMÉRICAINES:CSA 22.2 NO. 46 UL 1278
Page 1 of 1
FOYER À ÉLECTRIQUE. HOMOLOGUE POUR
INSTALLATION DANS UNE CHAMBRE A
COUCHER, UNE SALLE DE BAIN ET UN STUDIO.
APPROPRIE POUR INSTALLATION DANS UNE
MAISON MOBILE.
ELECTRIC FIREPLACE. SUITABLE FOR
BEDROOM AND BED-SITTING ROOM
INSTALLATION. SUITABLE FOR MOBILE
HOME INSTALLATION.
VOLTAGE: 120 VAC TENSION: 120VCA
FREQUENCY
: 60Hz FRÉQUENCE: 60Hz
POWER: 1500W PUISSANCE: 1500W
DATE CODE: XXXXX CODE DE DATE:
DESIGNED IN NORTH AMERCIA
BY WOLF STEEL LTD.
MADE IN CHINA
FABRIQUE EN CHINE
WOLF STEEL LTD.
24 NAPOLEON ROAD,
BARRIE, ON, L4M 0G8 CANADA
SERIAL NUMBER/NO. DE SERIE:
NEFI24
MATERIAL: CLASS IIIA-2 PERMANENT LEXAN ADHESIVE LABEL, MINIMUM THICKNESS 0.1MM, 121°C (250°F) RATING
SPECIFICATION: BLACK LETTERING ON WHITE BACKGROUND. MINIMUM FONT SIZE TO BE MINIMUM OF 8.5 PT (3.2mm)
MAX OVERALL SIZE: 6" x 3"
SERIAL NUMBERS TO BE ASCENDING FROM NEFI24 00601
TITLE: RATING PLATE NEFI24H
REVISION: A : REMOVED NEF127H, ADDED FRENCH || 06.01.15
DWG#: W385-2026
DATE: 03.23.15
DESIGN AMERIQUE DE NORD
PAR WOLF STEEL LTD.
MASTER CONTRACT: 161746
CONTRAT-CADRE: 161746
MODEL / MODÈLE:
NEFI24H
A
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model of the appliance.
For rating plate location, see “LABEL LOCATION” section.
This illustration is for reference only. Refer to the rating plate on the log set for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
SAMPLE
1.5 LABEL LOCATION
GREEN
BLACK
WHITE
CAUTION LABEL
(W385-1945)
"DO NOT COVER"
LABEL (W385-1946)
WARNING
LABEL
(W385-1943)
FRONT
RIGHT SIDE
LEFT SIDE
WARNING LABEL
(W385-1944)
RATING PLATE WITH
SERIAL NUMBER
NEFI24H (W385-2026)
NEFI27H (W385-2066)
NOTE: Do not use the log set during mobile home transportation.
ATTENTION
LABEL
(W385-2133)
EN
7
!
WARNING
2.0 LOCATING LOG SET
2.1 UNPACKING AND TESTING LOG SET
Carefully remove the appliance from the box and remove the support brackets. Prior to installing the
appliance, remove all packaging material and test to make sure the appliance operates properly by plugging
the power supply cord into a conveniently located 120V, 15 Amp minimum grounded outlet.
2.2 GROUNDING LOG SET
DUE TO HIGH TEMPERATURES, THIS ELECTRIC APPLIANCE SHOULD BE LOCATED OUT OF
TRAFFIC. KEEP COMBUSTIBLE MATERIALS SUCH AS FURNITURE, PILLOWS, BEDDING, PAPERS,
CLOTHES AND CURTAINS AT LEAST 36" FROM THE FRONT OF THE APPLIANCE.
NEVER LOCATE THIS ELECTRIC APPLIANCE WHERE IT MAY FALL INTO A BATHTUB OR OTHER
WATER CONTAINER.
WEAR SAFETY GLOVES AND SAFETY GLASSES FOR PROTECTION DURING INSTALLATION AND
MAINTENANCE.
TO PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION, THE ELECTRIC APPLIANCE
MUST NOT BE INSTALLED AGAINST VAPOR BARRIER OR EXPOSED INSULATION. LOCALIZED
OVERHEATING COULD OCCUR AND A FIRE COULD RESULT.
DO NOT EXPOSE THE ELECTRIC APPLIANCE TO THE ELEMENTS (SUCH AS RAIN, ETC.)
96.1
GROUNDING METHODS
METAL SCREW
(A)
NOT ALLOWED IN CANADA
GROUNDING
MEANS
ADAPTER
GROUNDING PIN
COVER OF
GROUNDED
OUTLET BOX
(C)
(B)
This appliance is for use on 120 volts. The cord has a plug
as shown in (A). An adapter as shown in (C) is available for
connecting three-blade grounding type plugs to two-slot
receptacles. The green grounding plug extending from the
adapter must be connected to a permanent ground such as
a properly grounded outlet box. The adapter should not be
used if a three-slot grounded receptacle is available.
To disconnect appliance, turn controls to off, then remove
plug from outlet.
NOTE: Must be connected to a dedicated 15 amp circuit.
The use of an extension cord is NOT permitted.
EN
W415-1461 / D / 08.29.18
8
3.0 INSTALLATION
NOTE: Follow all National and local electrical codes.
!
WARNING
RISK OF FIRE! THE POWER CORD MUST NOT BE PINCHED AGAINST A SHARP EDGE. SECURE CORD TO AVOID
TRIPPING OR SNAGGING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY. DO NOT RUN
CORD UNDER CARPETING. DO NOT COVER CORD WITH THROW RUGS, RUNNERS OR THE LIKE. ARRANGE CORD
AWAY FROM TRAFFIC AREAS AND WHERE IT WILL NOT BE TRIPPED OVER.
RISK OF FIRE! TO PREVENT A POSSIBLE FIRE, DO NOT BLOCK AIR INTAKE OR EXHAUST IN ANY MANNER. DO NOT
USE ON SOFT SURFACES WHERE OPENINGS MAY BECOME BLOCKED.
RISK OF FIRE! DO NOT BLOW OR PLACE INSULATION AGAINST THE APPLIANCE.
THIS ELECTRIC APPLIANCE IS TESTED AND LISTED FOR USE ONLY WITH THE APPROVED OPTIONAL ACCESSORIES.
USE OF OPTIONAL ACCESSORIES NOT SPECIFICALLY TESTED FOR THIS ELECTRIC APPLIANCE COULD VOID THE
WARRANTY AND/OR RESULT IN A SAFETY HAZARD.
IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
THIS APPLIANCE IS HEAVY. IT IS HIGHLY RECOMMENDED THAT TWO PEOPLE INSTALL THIS APPLIANCE.
HEATER VENTS ON THE ELECTRIC APPLIANCE CANNOT, IN ANY WAY, BE COVERED AS IT MAY CREATE A FIRE
HAZARD.
DO NOT RUN THE POWER CORD HORIZONTALLY, DIRECTLY BELOW THE APPLIANCE.
68.5A
Do not install the log set
into a cavity smaller than
that referenced in the
table.
HEIGHT WIDTH DEPTH
LOG SET A B C
NEFI24H 15"
(381mm)
24"
(610mm)
14"
(356mm)
NEFI27H 16"
(406mm)
27 1/2"
(698mm)
14"
(356mm)
A
B
C
3.1 LOG SET INSTALLATION
The log set can be installed in any location. It is suggested to install the log set into an existing fireplace or a
wood mantel for aesthetic purposes.
Select a suitable location that is not susceptible to moisture and is away from drapes, furniture and high
traffic areas.
3.1.1 INSTALLING LOG SET INTO EXISTING FIREPLACE
MINIMUM FIREPLACE CAVITY SIZE
The log set insert must be installed in an opening with the minimum cavity sizes shown below:
NOTE: Seal all chimney drafts with non-combustible materials to prevent any chimney debris from
falling onto the log set. Cap the top of the chimney flue to prevent rain from entering.
Plug the log set into an outlet which has a 15Amp, 120V rating. If it is necessary to hard wire the log set see
"HARD WIRING INSTALLATION" section.
WARNING: Due to the high temperatures, do not use existing fireplace doors which close or seal off
the log set. If installed behind any fireplace door, allow heat to be exhausted. If using existing screens,
the screen must provide adequate airflow in front of the log set.
EN
9
Fig. 2
3.1.2 INSTALLING LOG SET INTO MANTEL
A. With two people, lift the log set up and insert into the opening. Do not push or slide the bottom of the
log set on the floor base, see Figure 1.
B. Set the log set down and into place, see Figure 2.
MANTEL
DO NOT SLIDE LOGSET
NE GLISSEZ PAS L'APPAREIL
!
!
MANTEL
STEP 1: LIFT
STEP 2: INSERT
STEP 3:
SET APPLIANCE
MANTEL
DO NOT SLIDE LOGSET
NE GLISSEZ PAS L'APPAREIL
!
!
MANTEL
STEP 1: LIFT
STEP 2: INSERT
STEP 3:
SET APPLIANCE
NOTE: To prevent damaging the base of the mantel, carefully lift the log set into the mantel while
avoiding contact with the front edge of the mantel base.
Fig. 1
NOTE: Leave enough
wire so that the log
set can be removed
from the enclosure
without disconnecting
the power supply.
A. Remove the securing screw from the electrical cover plate, located on the rear of the log set.
B. Add an electrical box connector and feed the supply wires through the 7/8" (22mm) hole.
C. Separate the black, white and green wires that have the wire nuts on them.
D. Remove the wire nuts and secure the black wire (power L1) to the black (power L1) lead of the
power supply. Connect the white wire from the unit to the white (neutral) wire from the power
supply. Connect the green wire to the ground wire.
E. Resecure the cover plate.
BLACK
WHITE
BLACK
WHITE
GREEN
GREEN
GROUND
BLACK
BLACK
BLACK
WHITE
WHITE
WIRE NUT
WALL
SWITCH
POWER
SUPPLY
MARRET
RED
RED
RED
RED
GREEN
GREEN
THERMOSTAT
(L1)
(N)
(G)
WIRE NUT
(L1)
(N)
(L1)
(N)
EN
W415-1461 / D / 08.29.18
10
GREEN
BLACK
WHITE
HARD WIRING CONNECTION
If it is necessary to hard wire, a qualified electrician must remove the cord connection, and wire directly to the
household wiring. The wire and power supply breaker must be rated for 120V and a minimum of 15 Amps.
This log set must be electrically connected and grounded in accordance with local codes, if hard wired. In
the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the
current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
!
WARNING
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED
SERVICE PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
NOTE: There are 3 wires from the fireplace junction; white (neutral), black (power L1) and green
(ground) that connect to 120V power supply (breaker panel), see below.
White, Green and
Black wires:
Connect to 120V
power supply.
3.2 HARD WIRING INSTALLATION
NOTE: It is recommended to
secure the log set after hard
wiring, refer to "SECURING
THE LOG SET" section.
A. Place the log set in a position which provides optimum flame performance. NOTE: To achieve flame
effect, the log set should be set 1" away from the rear wall.
B. Secure in place using 2 screws (not supplied).
EN
11
3.3 SECURING THE LOG SET
NOTE: It is recommended to secure the log set especially if hard wiring the log set.
POWER
Turns the appliance ON/OFF.
FLAME & EMBER LIGHT
CONTROL
HEATER CONTROL
TIMER
TEMPERATURE
CONTROL
Controls Flame brightness and the Ember Light.
5 Settings
: Flame & Ember off (FO), Ember on but Flame
off (LL), small Flame & Ember (F1), medium Flame &
Ember (F2), brightest Flame and Ember (F3).
Default setting is (F3).
Turns the Heater and Blower ON/OFF.
4 Settings: Heater & Blower off (HO), Blower on (BL), low
heat (H1), high heat (H2).
Default setting is (HO).
Timer can be programed to run appliance for specific
lengths of time (30mins. minimum to 6hrs maximum).
Default setting is Timer de-select.
Press and hold the Timer button for 5 seconds. This
will change the button to Temperature Control, or vice
versa. There are 7 temperature settings (61
°F, 64°F, 70°
F,
75
°F, 81°F, 85°F and OFF).
Default setting is de-select Temperature Control.
F° / C° SWITCH
Hold 5
seconds
To change temperature format, Fahrenheit or Celsius.
Press and hold the Flame button for 5 seconds.
Default setting is Fahrenheit.
HEATER LOCK
Hold 5
seconds
Heater button can be locked or unlocked by holding the
Heater button for 5 seconds.
Default setting is heater unlock
Hold 5
seconds
EN
W415-1461 / D / 08.29.18
12
4.0 OPERATING INSTRUCTIONS
Once the log set has been plugged into a grounded electrical outlet or hard wired to a dedicated 120V power
supply, it is ready to operate.
ATTENTION: Ensure the house circuit breakers for the power supply are turned on. When initially
connecting the appliance into a power source the unit will perfom an LED check. The unit will flash
on and off for 5 seconds.
The Control Panel is located on the front of the log set.
4.1 OPERATING CONTROL PANEL
EN
13
4.2 OPERATING BY REMOTE CONTROL
!
WARNING
TO AVOID DANGER OF SUFFOCATION KEEP THE PACKAGING BAG AWAY FROM BABIES AND
CHILDREN. DO NOT USE IN CRIBS, BED, CARRIAGES OR PLAY PENS. THIS BAG IS NOT A TOY.
KNOT BEFORE THROWING AWAY.
A. The power button can be used to turn the log set on/off. Pressing
this button activates the power to the log set. Pressing the
power button again will turn off the log set. The ember and log will
fade after 4 seconds after turning off the log set.
B. To adjust the flame brightness and ember log light, press the flame
button . There is one ember log light and three flame brightness
levels to cycle through and then an off setting (LL, F1, F2, F3 and
then F0). F3 is the brightest flame level, LL is the ember log light
only.
C. To control the thermostat function press the thermostat button .
There are 7 temperature settings (61°F, 64°F, 70°F, 75°F, 81°F 85°F
and off). The default setting will display Fahrenheit. Press the
thermostat button to cycle through the settings. Once you have
selected the desired temperature the heater will automatically
operate until that temperature is reached. When the room
temperature is 2 degrees lower than the temperature setting, the
heater will turn on.
D. To activate the heater and blower, press the heater button , the
blower will turn on. Press the heater button again to set desired low
or high heat temperature; press the heater button again to turn off
the heater.
E. The timer controls all operating modes of the log set. To activate the
timer, press the timer button , the icon will illuminate and the time
will appear on the LED display. To choose the desired time, continue to press the timer button, there
are 8 settings (30mins,1h, 2h, 3h, 4h, 5h, 6h and off). The fireplace will turn off at the setting time.
F. To turn off the log set, press the power button once on the remote, or press the power button once on
the control panel on the unit.
NOTE: This hand held remote control must remain within 6 meters or 19 feet of the log set to be
effective.
NOTE: When operating the remote control, it must be directed towards the front center of the log set.
4.3 REMOTE BATTERY INSTALLATION
1. To replace the existing battery, remote the battery
holder.
2. To remove the battery holder, turn remote onto
front side and press the left side lever towards the
center while pulling the battery holder out using the
slot provided.
3. Replace existing battery, type CR 2025, with a
new battery and reinstall the battery holder into the
remote by sliding it into position, as shown.
4. Battery cover is secure onto the remote control
when a "CLICKING" noise is heard.
REMOTE
(REAR SIDE)
BATTERY (CR 2025)
BATTERY COVER
EN
W415-1461 / D / 08.29.18
14
5.0 FINISHING
!
WARNING
POWER SUPPLY SERVICE MUST BE COMPLETED PRIOR TO FINISHING TO AVOID
RECONSTRUCTION.
HEAT VENTS AND AIR OPENINGS CANNOT BE COVERED IN ANY CIRCUMSTANCES.
NEFI24H
NEFI27H
Place the log (#1) onto the pin.
Ensure the log is secure onto the
pin, as shown.
Place log (#2) onto the pin. Ensure
the log is secure onto the pin, as
shown.
Place the logs shown on the location
dimples on the burner platform.
Place the logs shown on the location
dimples on the burner platform.
#1
NEFI24H
NEFI27H
#2
PIN
NEFI24H
NEFI27H
#1
PIN
PIN
Place log (#1) onto the pin. Ensure the log
is secure onto the pin, as shown.
5.1 NEFI24H LOG PLACEMENT
5.2 NEFI27H LOG PLACEMENT
1
3
1 2
2
EN
15
Place log (#2) onto the pin. Ensure the log
is secure onto the pin, as shown.
Place log (#3) onto the pin. Ensure the log
is secure onto the pin, as shown.
NEFI24H
NEFI27H
#2
NEFI24H
NEFI27H
#3
PIN
5.3 EMBER BED PLACEMENT
Place the ember bed over the LED tray, as
shown.
3 4
EN
W415-1461 / D / 08.29.18
16
A. Place the charcoal ember around the front and sides of the ember bed, as indicated on the diagram
below.
NOTE: Do not block air intake opening and outlet with charcoal embers.
CHARCOAL
EMBERS
OUTLET
OPENING
AIR INTAKE
OPENING
BRAISES DE
CHARBON
L’OUVERTURE
D’AIR
L’OUVERTURE DU
VOLET D’AIR
5.4 CHARCOAL EMBER PLACEMENT
NEFI24H ILLUSTRATED
EN
17
6.0 WIRING DIAGRAM
!
WARNING
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED
SERVICE PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
PLUG /
FICHE
FAN /
SOUFFLERIE
MOTOR /
MOTEUR
AC-N
AC-L
RLY1 RLY2 RLY3 RLY4
NTC
OUTOUT
OUT
IN
#7
#8
#5
#6
#2 #4
#14
#1
#9
#3
#11
#12
#13
#10
#15
CARTE DE CIRCUIT IMPRIMÉ
MAIN PCB BOARD /
L
N
G
WIRE NUT /
CONNECTEUR
DE FILS
WIRE NUT /
CONNECTEUR
DE FILS
WIRE NUT /
CONNECTEUR
DE FILS
HEATER 700W2 /
CHAUFFERETTE 700W2
HEATER 700W1 /
CHAUFFERETTE 700W1
THERMAL CUT-OFF /
COUPURE
THERMIQUE
700W1
700W2
MOTOR /
MOTEUR
FAN /
SOUFFLERIE
T-FUSE /
FUSIBLE
FLAME /
FLAMME
DISPLAY CN3 /
AFFICHAGE
TEMPERATURE
SENSOR /
CAPTEUR DE
EMPÉRATURE
CONTROL PANEL BOARD /
PANNEAU DE CONTRÔLÉ
FLAME LED LIGHT /
LUMIÈRE DEL DE FLAMME
LOG LIGHT /
DEL DES BÛCHES
#1 EMBER BED LIGHT /
#1 LUMIÈRE LIT DE BRAISES
LOG LIGHT /
DEL DES BÛCHES
#2 EMBER BED LIGHT /
#2 LUMIÈRE LIT DE BRAISES
EN
W415-1461 / D / 08.29.18
18
41.1C
Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts
can be ordered through your Authorized dealer / distributor.
FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE
REQUIRED TO HONOUR THE CLAIM.
When ordering replacement parts always give the following information:
Model & Serial Number of appliance
Installation date of appliance
Part number
Description of part
Finish
PARTS, PART NUMBERS AND AVAILABILITY ARE SUBJECT TO CHANGE WITHOUT NOTICE.
PARTS IDENTIFIED AS STOCKED WILL BE DELIVERED WITHIN 2 TO 5 BUSINESS DAYS FOR MOST
DELIVERY DESTINATIONS.
PARTS NOT IDENTIFIED AS STOCKED WILL BE DELIVERED WITHIN A 2 TO 4 WEEK PERIOD, FOR
MOST CASES.
PARTS IDENTIFIED AS ‘SO’ ARE SPECIAL ORDER AND CAN TAKE UP TO 90 DAYS FOR DELIVERY.
FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE
ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY
DAMAGE OR PERSONAL INJURY.
** THIS IS A FAST ACTING THERMOCOUPLE. IT IS AN INTEGRAL SAFETY COMPONENT. REPLACE ONLY WITH
A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
!
WARNING
For after sales service, please call 1-866-820-8686
7.0 REPLACEMENT PARTS
EN
19
NOTE: Care must be taken when removing and disposing of any broken glass or damaged
components. Be sure to vacuum up any broken glass from inside the appliance before operation.
ITEMS MAY NOT APPEAR EXACTLY AS ILLUSTRATED
3
15
2216
13
14
1
2
3
25
5
6
39
3
10
3
11
3
12
23
22
24
7
8
4
NEFI24H 02.01.16
17
W135-0604
W135-0603
W135-0600
W135-0602
W135-0601
19
18
20
21
22
DESCRIPTIONPART NO.REF.
14
15
16
17
18
19
20
21
22
23
24
25
G660-0004
G750-0032
W010-3833-SER
W135-0604
W135-0601
W135-0603
W135-0600
W135-0602
W135-0610
W550-0013
G405-0011
G190-0005
DESCRIPTIONPART NO.REF.
1 W135-0605
2
3
4
5
6
7
8
9
10
11
12
13
W405-0023
W405-0025
G405-0012
W435-0059
W005-0019
W010-3617
W105-0020
G010-0081
G190-0006
G190-0004
G010-0079
G615-0002
EMBER BED, FRONT
EMBER BED LED
FLAME LED, NEFI24H
LOG LED
SYNCHRONOUS MOTOR
ADAPTOR
REFLECTOR, NEFI24H
BUSHING
CONTROL PANEL, NEFI24H
CONTROL PANEL BOARD
TEMPERATURE
SENSOR
BLOWER & HEATER ASSEMBLY
SPACER, 4PCS
MAIN PCB BOARD
REMOTE CONTROL TRANSMITTER
WIRE ASSEMBLY
LOG SERVICE PART KIT
, NEFI24H
TOP LEFT LOG
FRONT LEFT LOG
TOP RIGHT LOG
REAR LOG
EMBER BED, REAR
FRONT RIGHT LOG
CHARCOAL, EMBER
REAR EMBER LED
7.1 NEFI24H OVERVIEW
EN
W415-1461 / D / 08.29.18
20
17
3
15
2216
13
14
1
2
3
5
39
3
10
3
12
24
2225
6
7
8
4
26
NEFI27H 02.01.16
W135-0609
W135-0604
W135-0603
W135-0607
W135-0606
W135-0608
11
ITEMS MAY NOT APPEAR EXACTLY AS ILLUSTRATED
18
20
21
22
19
23
DESCRIPTION
REF.
PART NO.
DESCRIPTION
REF.
PART NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
W135-0605
W405-0023
W405-0025
G405-0012
W435-0059
W005-0019
W010-3617
W105-0020
G010-0081
G190-0006
G190-0004
G010-0079
W615-0135
EMBER BED, FRONT
EMBER BED LED
FLAME LED, NEFI24H
LOG LED
SYNCHRONOUS MOTOR
ADAPTOR
REFLECTORTOR, NEFI27H
BUSHING
CONTROL PANEL, NEFI27H
CONTROL PANEL BOARD
TEMPERATURE SENSOR
BLOWER & HEATER ASSEMBLY
SPACER, 4 PCS
14
15
16
17
18
19
20
21
22
23
24
25
26
G190-0005
G660-0004
W750-0359
W010-3834-SER
W135-0610
G020-0014
G405-0011
EMBER BED, REAR
CHARCOAL, EMBER
REAR EMBER LED
MAIN PCB BOARD
REMOTE CONTROL TRANSMITTER
WIRE ASSEMBLY NEFI24H/NEFI27H
LOG SERVICE PART KIT, NEFI27H
TOP LEFT LOG
TOP CENTRE LOG
TOP RIGHT LOG
REAR LOG
FRONT RIGHT LOG
FRONT LEFT LOG
W135-0609
W135-0608
W135-0604
W135-0603
W135-0606
W135-0607
NOTE: Care must be taken when removing and disposing of any broken glass or damaged
components. Be sure to vacuum up any broken glass from inside the appliance before operation.
7.2 NEFI27H OVERVIEW
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Wolf Steel NEFI27H Le manuel du propriétaire

Catégorie
Cheminées
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues