Empire Heating Systems DV55E Le manuel du propriétaire

Taper
Le manuel du propriétaire

Ce manuel convient également à

Page 1
Patent # 5.664.555
FAN TYPE DIRECT VENT
WALL FURNACE
For Installation In
Manufactured (Mobile Home),
Modular Or Residential Homes
MODELS:
DV-55E-5
This appliance may be installed as an OEM
installation in a manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's in-
structions and the Manufactured Home Con-
struction and Safety Standard, Title 24 CFR,
Part 3280, in the United States, or the Mobile
Home Standard, CAN/CSA Z240 MH Series,
in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. A conver-
sion kit is supplied with the appliance.
WARNING
FIRE OR EXPLOSION HAZARD
If the information in these instructions is

may result causing property damage,
personal injury or loss of life.
Do not store or use gasoline or other

vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
 
 
not use any phone in your building.
 
 
from a neighbors phone. Follow the
gas suppliers instructions.
 

Installation and service must be

service agency or the gas supplier.
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING
If not installed, operated and maintained in
accordance with the manufacturer's instructions,
this product could expose you to substances in
fuel or from fuel combustion which can cause
death or serious illness.
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
19563-9-0519Page 2
TABLE OF CONTENTS
SECTION PAGE
Important Safety Information ..................................................................................................................................... 3
Safety Information for Users of Propane Gas ........................................................................................................... 4
Requirements for Massachusetts ............................................................................................................................. 5
Introduction ............................................................................................................................................................ 6-7
Specications ............................................................................................................................................................ 7
Gas Supply ............................................................................................................................................................... 8
Gas Conversion Instructions ..................................................................................................................................... 9
Clearances .............................................................................................................................................................. 10
Furnace Installation ............................................................................................................................................ 10-12
Lighting Instructions ............................................................................................................................................... 13
Wiring ...................................................................................................................................................................... 14
Maintenance ........................................................................................................................................................... 15
Operation and Troubleshooting .......................................................................................................................... 16-17
How to Order Repair Parts ...................................................................................................................................... 18
Parts List ................................................................................................................................................................ 18
Parts View ............................................................................................................................................................... 19
Warranty .................................................................................................................................................................. 20
19563-9-0519 Page 3
 

draperies.
 
of high surface temperatures and should stay away
to avoid burns or clothing ignition.
 
they are in the same room as the appliance.
 
placed on or near the appliance.
 
an appliance must be replaced prior to operating the
appliance.
 
 
 
or residential installation convertible for use with
      
provision is made for the simple conversion from
one gas to the other.
 Installation and repair should be done by a QUALIFIED
SERVICE PERSON. The appliance should be
inspected before use and at least annually by a
     
       
carpeting, bedding materials, etc. It is imperative
that control compartments, burners and circulating
air passageways of the appliance be kept clean.
 put anything around the furnace that will

  keep the appliance area clear and free from


  examine venting system periodically and replace
damaged parts.
 make a periodic visual check of burner. Clean
and replace damaged parts.
 use this heater if any part has been under

to inspect the heater and to replace any part of the
control system and any gas control which has been
under water.
THIS IS A HEATING APPLIANCE
DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED.
IMPORTANT SAFETY INFORMATION
19563-9-0519Page 4
Some people cannot smell well. Some people cannot smell the
odor of the chemical put into the gas. You must nd out if you can
smell the odorant in propane. Smoking can decrease your ability
to smell. Being around an odor for a time can affect your sensitivity
or ability to detect that odor. Sometimes other odors in the area
mask the gas odor. People may not smell the gas odor or their
minds are on something else. Thinking about smelling a gas odor
can make it easier to smell.
The odorant in Propane Gas is colorless, and it can fade under
some circumstances. For example, if there is an underground leak,
the movement of the gas through soil can lter the odorant. Odor-
ants in Propane Gas also are subject to oxidation. This fading can
occur if there is rust inside the storage tank or in iron gas pipes.
The odorant in escaped gas can adsorb or absorb onto or into
walls, masonry and other materials and fabrics in a room. That will
take some of the odorant out of the gas, reducing its odor intensity.
Propane Gas may stratify in a closed area, and the odor intensity
could vary at different levels. Since it is heavier than air, there may
be more odor at lower levels. Always be sensitive to the slightest
gas odor. If you detect any odor, treat it as a serious leak. Imme-
diately go into action as instructed earlier.
Propane is a ammable gas which can cause res and explosions.
In its natural state, propane is odorless and colorless. You may not
know all the following safety precautions which can protect both you
and your family from an accident. Read them carefully now, then
review them point by point with the members of your household.
Someday when there may not be a minute to lose, everyone's
safety will depend on knowing exactly what to do. If, after reading
the following information, you feel you still need more information,
please contact your gas supplier.
Learn to recognize the odor of Propane Gas. Your local Propane
Gas Dealer can give you a "Scratch and Sniff" pamphlet. Use
it to nd out what the propane odor smells like. If you suspect
that your Propane Gas has a weak or abnormal odor, call your
Propane Gas Dealer.
If you are not qualied, do not light pilot lights, perform service,
or make adjustments to appliances on the Propane Gas system.
If you are qualied, consciously think about the odor of Propane
Gas prior to and while lighting pilot lights or performing service
or making adjustments.
Sometimes a basement or a closed-up house has a musty
smell that can cover up the Propane Gas odor. Do not try to
light pilot lights, perform service, or make adjustments in an
area where the conditions are such that you may not detect
the odor if there has been a leak of Propane Gas.
Odor fade, due to oxidation by rust or adsorption on walls of
new cylinders and tanks, is possible. Therefore, people should
be particularly alert and careful when new tanks or cylinders
are placed in service. Odor fade can occur in new tanks, or
reinstalled old tanks, if they are lled and allowed to set too
long before relling. Cylinders and tanks which have been out
of service for a time may develop internal rust which will cause
odor fade. If such conditions are suspected to exist, a periodic
sniff test of the gas is advisable. If you have any question about
the gas odor, call your Propane Gas Dealer. A periodic sniff
test of the Propane Gas is a good safety measure under any
condition.
If, at any time, you do not smell the Propane Gas odorant and
you think you should, assume you have a leak. Then take the
same immediate action recommended above for the occasion
when you do detect the odorized Propane Gas.
If you experience a complete "gas out," (the container is under
no vapor pressure), turn the tank valve off immediately. If the
container valve is left on, the container may draw in some air
through openings such as pilot light orices. If this occurs,
some new internal rusting could occur. If the valve is left
open, then treat the container as a new tank. Always be sure
your container is under vapor pressure by turning it off at the
container before it goes completely empty or having it relled
before it is completely empty.
Do not operate electric switches, light matches, use your phone.
Do not do anything that could ignite the gas.
Get everyone out of the building, vehicle, trailer, or area. Do
that IMMEDIATELY.
Close all gas tank or cylinder supply valves.
Propane Gas is heavier than air and may settle in low areas
such as basements. When you have reason to suspect a gas
leak, keep out of basements and other low areas. Stay out until
reghters declare them to be safe.
Use your neighbor's phone and call a trained Propane Gas
service person and the re department. Even though you may
not continue to smell gas, do not turn on the gas again. Do not
re-enter the building, vehicle, trailer, or area.
Finally, let the service man and reghters check for escaped
gas. Have them air out the area before you return. Properly
trained Propane Gas service people should repair the leak,
then check and relight the gas appliance for you.
SOME POINTS TO REMEMBER
NO ODOR DETECTED - ODOR FADE
PROPANE GAS WARNING ODOR
If a gas leak happens, you should be able to smell the gas because of the odorant put in the Propane Gas.
That's your signal to go into immediate action!
SAFETY INFORMATION FOR USERS OF PROPANE GAS
19563-9-0519 Page 5
REQUIREMENTS FOR MASSACHUSETTS
For all side wall horizontally vented gas fueled equipment
installed in every dwelling, building or structure used in whole
or in part for residential purposes, including those owned or
operated by the Commonwealth and where the side wall
exhaust vent termination is less than seven (7) feet above
nished grade in the area of the venting, including but not
limited to decks and porches, the following requirements
shall be satised:
1.
INSTALLATION OF CARBON MONOXIDE DETEC-
TORS.
At the time of installation of the side wall horizontal
vented gas fueled equipment, the installing plumber or
gastter shall observe that a hard wired carbon monoxide
detector with an alarm and battery back-up is installed on
the oor level where the gas equipment is to be installed.
In addition, the installing plumber or gastter shall observe
that a battery operated or hard wired carbon monoxide
detector with an alarm is installed on each additional
level of the dwelling, building or structure served by the
side wall horizontal vented gas fueled equipment. It shall
be the responsibility of the property owner to secure the
services of qualied licensed professionals for the instal-
lation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas
fueled equipment is installed in a crawl space or an
attic, the hard wired carbon monoxide detector with
alarm and battery back-up may be installed on the
next adjacent oor level.
b. In the event that the requirements of this subdivision
can not be met at the time of completion of installa-
tion, the owner shall have a period of thirty (30) days
to comply with the above requirements; provided,
however, that during said thirty (30) day period, a
battery operated carbon monoxide detector with an
alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each
carbon monoxide detector as required in accordance with
the above provisions shall comply with NFPA 720 and
be ANSI/UL 2034 listed and IAS certied.
3. SIGNAGE. A metal or plastic identication plate shall be
permanently mounted to the exterior of the building at
a minimum height of eight (8) feet above grade directly
in line with the exhaust vent terminal for the horizontally
vented gas fueled heating appliance or equipment. The
sign shall read, in print size no less than one-half (1/2)
inch in size,    
CLEAR OF ALL OBSTRUCTIONS”.
4. INSPECTION. The state or local gas inspector of the
side wall horizontally vented gas fueled equipment shall
not approve the installation unless, upon inspection,
the inspector observes carbon monoxide detectors and
signage installed in accordance with the provisions of 24
8 5.08(2)(a) 1 through 4.
(b) EXEMPTIONS: The following equipment is exempt
from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled
“Equipment Not Required To Be Vented” in the
most current edition of NFPA 54 as adopted by
the Board; and
2. Product Approved side wall horizontally vented
gas fueled equipment installed in a room or
structure separate from the dwelling, building or
structure used in whole or in part for residential
purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIP-
MENT VENTING SYSTEM PROVIDED. When the
manufacturer of Product Approved side wall hori-
zontally vented gas equipment provides a venting
system design or venting system components with
the equipment, the instructions provided by the
manufacturer for installation of the equipment and
the venting system shall include:
1. Detailed instructions for the installation of the
venting system design or the venting system
components; and
2. A complete parts list for the venting system design
or venting system.
(e) A copy of all installation instructions for all Product
Approved side wall horizontally vented gas fueled
equipment, all venting instructions, all parts lists for
venting instructions, and/or all venting design instruc-
tions shall remain with the appliance or equipment
at the completion of the installation.
19563-9-0519Page 6
Introduction
Always consult your local Building Department regarding
regulations, codes or ordinances which apply to the installation
of a direct vent wall furnace.
Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer should show owner how to start and operate
furnace and thermostat.
3. Installer must locate unit near a grounded wall receptacle
for 115VAC power and must provide gas supply and vent
the unit properly for safe operation.
WARNING
Any change to this furnace or its control can be
dangerous. This is a heating appliance and any panel,
door or guard removed for servicing an appliance must
be replaced prior to operating the appliance.
General Information
This series is design certied in accordance with American
National Standard / CSA Standard Z21.86 and CSA 2.32 by the
Canadian Standards Association as a Fan Type Direct Vent
Wall Furnace to be installed according to these instructions.
Any alteration of the original design, installed other than
as shown in these instructions or use with a type of gas
not shown on the rating plate is the responsibility of the
person and company making the change.
Important
All correspondence should refer to complete Model Number,
Serial Number and type of gas.
NOTICE: During initial ring of this unit, oil from the heat
exchanger may bake out and smoke may occur. To prevent
triggering of smoke alarms, ventilate the room in which the
unit is installed.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be
installed so that all burners and burner ignition devices are
located not less than 18" (457mm) above the oor.
Such equipment shall be located, or protected, so it is not
subject to physical damage by a moving vehicle.

Installation and replacement of gas piping, gas utilization
equipment or accessories and repair and servicing of
equipment shall be performed only by a qualied agency. The
term "qualied agency" means any individual, rm, corporation
or company which either in person or through a representative
is engaged in and is responsible for (a) the installation or
replacement of gas piping or (b) the connection, installation,
repair or servicing of equipment, who is experienced in such
work, familiar with all precautions required and has complied
with all the requirements of the authority having jurisdiction.
Commonwealth of Massachusetts: The installation
must be made by a licensed plumber or gas tter in the
Commonwealth of Massachusetts.
The installation must conform with local codes, or in the
absence of local codes, the National Fuel Gas Code, ANSI
Z223.1/NFPA 54 or Natural Gas and Propane Installation
Code, CSA B149.1.
*Available from the American National Standards Institute,
Inc., 11 West 42nd St., New York, NY 10036.
A manufactured home (USA only) or mobile home OEM
installation must conform with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280,
or, when such a standard is not applicable, the Standard
for Manufactured Home Installations, ANSI Z225.1, or
Standard for Gas Equipped Recreational Vehicles and
Mobile Housing, CSA Z240.4.
High Altitudes
For altitudes/elevations above 2,000 feet (610m), input
ratings should be reduced at the rate of 4 percent for each
1,000 feet (305m) above sea level, this may be accomplished
by reducing manifold pressure. The maximum allowable
reduction in manifold pressure for Natural Gas shall be from
3.5" w.c. (.872kPa) to 2.8" w.c. (.697kPa). The maximum
allowable reduction in manifold pressure for Propane Gas
shall be from 10.0" w.c. (2.49kPa) to 8.0" w.c. (1.99kPa). For
Canadian high altitude applications, this appliance is suitable
for installation at elevations between 0 feet (0m) and 4,500
feet (1,372m) without change.
INTRODUCTION
19563-9-0519 Page 7
Model DV-55E
Input BTU/HR (KW/H) 55,000 (16.1)
Height 26" (660mm)
Width 37" (940mm)
Depths with Shroud 15 3/4" (400mm)
Gas Inlet (Pipe) 1/2" (13mm)
Electrical - Unit has a 5' (1.5m) 3 pronged cordset for
connection to an approved 115 VAC 60HZ
minimum AMPs - 5A wall receptacle.
Accessories for DV-55E Furnaces
Extended Vent Terminal
For walls up to 32"
(813mm)
DVT-2
Floor Pad DVP-1
SPECIFICATIONS
INTRODUCTION (CONT'D)

Model Number Description Used On
DV1153 Propane to Natural DV55E-5LPG
DV1152 Natural to Propane DV55E-5NAT
When an existing Category 1 heater is removed or replaced,
the original venting system may no longer be sized to
properly vent the attached appliances. Instructions shall
also indicate effects of an improperly sized venting system
(formation of condensate, leakage, spillage, etc.) and shall
specify the following test procedure:
WARNING
CARBON MONOXIDE POISONING HAZARD
Failure to follow the steps outlined below for each
appliance connected to the venting system being
placed into operation could result in carbon monoxide
poisoning or death.
The following steps shall be followed for each
appliance connected to the venting system being
placed into operation, while all other appliances
connected to the venting system are not in operation:
1. Seal any unused openings in the venting system.
2.        

Gas Code, ANSI Z223.1/NFPA 54 or the Natural
Gas and Propane Installation Code, CSA B149.1
and these instructions. Determine that there is no
blockage or restriction, leakage, corrosion and
      
condition.
3. As far as practical, close all building doors and
windows and all doors between the space in which
the appliance(s) connected to the venting system
are located and other spaces of the building.
4. 
5. Turn on clothes dryers and any appliance not
connected to the venting system. Turn on any
exhaust fans, such as range hoods and bathroom
exhausts, so they are operating at maximum
speed. Do operate a summer exhaust fan.
6. Follow the lighting instructions. Place the appliance
being inspected into operation. Adjust the
thermostat so appliance is operating continuously.
7.       
appliances at the draft hood relief opening after 5

of a match or candle.
8. If improper venting is observed during any of the
above tests, the venting system must be corrected
in accordance with National Fuel Gas Code, ANSI
Z223.1/NFPA 54 and/or Natural Gas and Propane
Installation Code, CSA B149.1.
9. After is has been determined that each appliance
connected
to the venting system properly vents
when tested as outlined above, return doors,
     
      
previous conditions of use.
19563-9-0519Page 8
Consult the current National Fuel Gas Code, ANSI Z223.1
CAN/CGA-B149 (.1 or .2) installation code.
Recommended Gas Pipe Diameter
Pipe
Length
Schedule 40 Pipe
Inside Diameter
Tubing, Type L
Outside Diameter
Natural Propane Natural Propane
0-10 feet
0-3 meters
1/2”
12.7mm
3/8”
9.5mm
1/2”
12.7mm
3/8”
9.5mm
10-40 feet
4-12 meters
1/2”
12.7mm
1/2”
12.7mm
5/8”
15.9mm
1/2”
12.7mm
40-100
feet 13-30
meters
1/2”
12.7mm
1/2”
12.7mm
3/4”
19mm
1/2”
12.7mm
100-150
feet 31-46
meters
3/4”
19mm
1/2”
12.7mm
7/8”
22.2mm
3/4”
19mm
NOTE: Never use plastic pipe. Check to conrm whether your
local codes allow copper tubing or galvanized.
NOTE: Since some municipalities have additional local
codes, it is always best to consult your local authority and
installation code.
The use of the following gas connectors is recommended:
ANS Z21.24 Appliance Connectors of Corrugated Metal
Tubing and Fittings
ANS Z21.45 Assembled Flexible Appliance Connectors
of Other Than All-Metal Construction
The above connectors may be used if acceptable by
the authority having jurisdiction. The Commonwealth of
Massachusetts requires that a exible appliance connector
cannot exceed three feet in length.
Figure 1
Installing a New Main Gas Shut-Off
Each appliance should have its own manual gas shut-off.
A manual main gas shut-off should be located in the vicinity
of the unit. Where none exists, or where its size or location
is not adequate, contact your local authorized installer for
installation or relocation.
Compounds used on threaded joints of gas piping shall be
resistant to the action of liqueed petroleum gases. The gas
lines must be checked for leaks by the installer. This should
be done with a soap solution watching for bubbles on all
exposed connections, and if unexposed, a pressure test
should be made.

must be disconnected from piping at inlet of control valve
and pipe capped or plugged for pressure test. Never

will sustain damage!
A gas valve and ground joint union should be installed in the
gas line upstream of the gas control to aid in servicing. It is
required by the National Fuel Gas Code that a drip line be
installed near the gas inlet. This should consist of a vertical
length of pipe tee connected into the gas line that is capped
on the bottom in which condensation and foreign particles
may collect.
Pressure Testing of the Gas Supply System
1. To check the inlet pressure to the gas valve, a 1/8"
(3mm) N.P.T. plugged tapping, accessible for test gauge
connection, must be placed immediately upstream of the
gas supply connection to the appliance.
2. The appliance and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psig (3.5 kPa).
3.
The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig (3.5 kPa).
Attention! If anyone of the procedures results in
pressures in excess of 1/2psig (14" w.c.) (3.5kPa) on the


Both Propane and Natural Gas valves have a built-in pressure
regulator in the gas valve. Natural Gas models will have a
manifold pressure approximately 3.5" w.c. (.872kPa) at the
valve outlet with the inlet pressure to the valve from a minimum
of 5.0" w.c. (1.245kPa) for the purpose of input adjustment to
a maximum of 10.5" w.c. (2.614kPa) Propane Gas models will
have a manifold pressure approximately 10.0" w.c. (2.49kPa)
at the valve outlet with the inlet pressure to the valve from
a minimum of 11.0" w.c. (2.739kPa) for the purpose of input
adjustment to a maxium of 13.0" w.c. (3.237kPa).
A 1/8" (3mm) N.P.T. plugged tapping, accessible for test gauge
connection, is located on the outlet side of the gas control.
GAS SUPPLY
19563-9-0519 Page 9

and new gas conversion label are provided in conversion kit attached to manifold pipe.
1. Make sure gas supply to furnace is off prior to conversion and disconnect electrical power to unit.
2. Open brass union located between the gas valve and burner box. Re-
move the 4 mounting screws securing manifold plate to the burner box.
Remove the top 2 screws holding the burner box top in place and then
remove the 1 screw holding the end of the manifold pipe in place. Grasp
union and remove manifold pipe.
3. Remove (1) Natural Gas main burner orice marked 44 for DV-20E, (2)
Natural Gas main burner orices marked 44 for DV-40E or (3) Natural
Gas main burner orices marked 47 for DV-55E located in the manifold
pipe and replace with (1) Propane Gas main burner orice marked 55
for DV-20E, (2) Propane Gas main burner orices marked 55 for DV-40E
or (3) Propane Gas main burner orices marked 1.20mm for DV-55E
supplied in conversion kit.
4. Replace manifold pipe being sure to locate orice(s) in the end of the burner. Secure the manifold and top burner box cover in place
using the screws earlier removed. Reconnect the brass union.
5. Remove the vinyl cap and unscrew the gas control convertible regulator and reverse to Propane Gas side (red ring on regulator)
and screw back into place. Reattach vinyl cap. Refer to gure illustrating the gas valve.
6. Place Natural Gas main burner orice(s) in conversion kit. Attach conversion kit to manifold pipe. Attach new label to unit nameplate
indicating that the unit was converted to Propane Gas.
7. Turn on gas supply to furnace and check all gas connections for leaks with soap solution, watching for bubbles on all gas connec-
tions.
8. Turn on electrical power to unit and turn on furnace to verify proper operation. It may take several tries for ignition to completely
purge all the air from the gas line.

and new gas conversion label are provided in conversion kit attached to manifold pipe.
1. Make sure gas supply to furnace is off prior to conversion and disconnect electrical power to unit.
2. Open brass union located between the gas valve and burner box.
Remove the 4 mounting screws securing manifold plate to the burner
box. Remove the top 2 screws holding the burner box top in place and
then remove the 1 screw holding the end of the manifold pipe in place.
Grasp union and remove manifold pipe.
3. Remove (1) Propane Gas main burner orice marked 55 for DV-20E,
(2) Propane Gas main burner orices marked 55 for DV-40E or (3)
Propane Gas main burner orices marked 1.20mm for DV-55E located
in the manifold pipe and replace with (1) Natural Gas main burner orice
marked 44 for DV-20E, (2) Natural Gas main burner orices marked
44 for DV-40E or (3) Natural Gas main burner orices marked 47 for
DV-55E supplied in conversion kit.
4. Replace manifold pipe being sure to locate orice(s) in the end of the burner. Secure the manifold and top burner box cover in place
using the screws earlier removed. Reconnect the brass union.
5. Remove the vinyl cap and unscrew the gas control convertible regulator and reverse to Natural Gas side and screw back into place.
The red propane ring will be up just under the vinyl cap. Reattach vinyl cap. Refer to gure illustrating the gas valve.
6. Place Propane Gas main burner orice(s) in conversion kit. Attach conversion kit to manifold pipe. Attach new label to unit nameplate
indicating that the unit was converted to Natural Gas.
7. Turn on gas supply to furnace and check all gas connections for leaks with soap solution, watching for bubbles on all gas connec-
tions.
8. Turn on electrical power to unit and turn on furnace to verify proper operation. It may take several tries for ignition to completely
purge all the air from the gas line.
CONVERSION INSTRUCTIONS FROM PROPANE GAS TO NATURAL GAS
CONVERSION INSTRUCTIONS FROM NATURAL GAS TO PROPANE GAS
TOPVIEW
BACKEND VIEW
GASCONTROLLEVERSHOWN
IN "OFF"POSITION
OFF
CONVERTIBLE
REGULATOR
VINYLCAP
VINYL CAP
CONVERTIBLE
REGULATO R
GAS CONTROL LEVER SHOWN
IN "OFF" POSITION
TOP VIEW
BACK END VIEW
GAS VALVE-NATURAL
TOPVIEW
BACKEND VIEW
GASCONTROLLEVERSHOWN
IN "OFF"POSITION
OFF
CONVERTIBLE
REGULATOR
VINYLCAP
VINYL CAP
CONVERTIBLE
REGULATO R
GAS CONTROL LEVER SHOWN
IN "OFF" POSITION
TOP VIEW
BACK END VIEW
GAS VALVE-PROPANE
GAS CONVERSION INSTRUCTIONS
19563-9-0519Page 10
1. Pick a location on a wall with a clear space of 36" (91.4cm)
high by 43" (109cm) wide in the room. In selecting
a location for installation, it is necessary to provide
adequate accessibility clearances for servicing and proper
installation. Be sure to locate the unit close enough to a
115 VAC wall receptacle to properly power appliance.
2. Unit is supported by a wall bracket secured to the wall.
3. When facing the front of the furnace the minimum
clearances from casing to combustible construction are
10" (254mm) on top, 3" (76mm) on each side, recommend
18" (457mm) on right side for servicing and 0" (0mm) from
the oor and 0" (0mm) to rear wall.
4. The minimum distance from the center of the vent cap to
the nearest outside corner or obstruction is 12" (305mm).
5. The minimum wall depth is 2" (51mm) and the maximum
is 10"(254mm) [or 32"(813mm) using the extended
vent terminal kit accessory]. The use of vent tubes not
supplied by the manufacturer may result in unsatisfactory
performance.
The vent terminal of a direct vent appliance, with an input
of 50,000 BTU (14.6KW) per hour or more shall be located
at least 12" (305mm) from any opening through which ue
gases could enter a building.
The bottom of the exhaust vent terminal and the air intake
shall be located at least 12" (305mm) above grade and must
be vented outside.
WARNING: The nearest point of the vent cap should be

any pressure regulator. In case of regulator malfunction,
the six (6) feet (1.83m) distance will reduce the chance
of gas entering the vent cap.
Installation on Rugs and Tile
If this appliance is to be installed directly on carpeting, tile,
or other combustible material, other than wood ooring, the
appliance shall be installed on a metal or wood panel extend-
ing the full width and depth of the appliance.
The base referred to above does not mean the re-proof
base as used on wood stoves. The protection is primarily
for rugs that may be extremely thick and light-color tile that
can discolor.
Locating Wall Opening (Figures 2, 3 and 4)
This furnace must be installed on an outside wall. Locate
wall studs so that wall vent opening will be located between
wall studs. The wall studs can be used for attachment of wall
mounting bracket. The wall opening required for venting is a
3 1/4" (83mm) diameter opening.
Refer to Figures 2 and 3 for positioning the furnace on
wall and for locating gas line connection and vent opening.
Furnace can sit on the oor and should be secured to the
wall through the wall bracket secured to the rear top shroud.
Figure 2
Figure 3
3"
(76mm)
8 3/4"
(222mm)
12 5/16"
20" (508mm)
(313 mm)
(267mm)
10 1/2"
1/2" (13mm) DIA.
GAS SUPPLY
WALL
MAYBE20" TO 13"
TO AVOID STUD
31/4"(83mm) DIA. VENT
HOLE THRU OUTSIDE WALL
17 11/16"
(449mm)
FLOOR TO
BOTTOM OF
WALL BRACKET
FRONT OF FURNACE
CLEARANCES
FURNACE INSTALLATION
19563-9-0519 Page 11
Figure 4
Installing Wall Bracket (Figures 5 and 6)
After nding a location for the furnace, gas supply and vent,
the wall bracket must be positioned and installed. The bracket
should be mounted to the wall studs, if possible, or anchored
solidly to the wall. Use the (2) 10 x 1 1/2" (38mm) hex-head
screws or (2) plastic anchors provided. Drill (2) 5/16" (8mm)
diameter holes in wall if plastic anchors are used. Attach the
two wall mounting brackets to the casing back by using (4)
10 x 1/2" (13mm) hex-head screws provided.
Figure 5
Figure 6
Figure 7
Figure 8
2" (51mm) TO 13" (330mm)
2" (51mm) TO 32" (813mm)
WALL
CASING
BACK
#10X1"
WALL MOUNTING BRACKET
WALL
BRACKET
#10X1/2"
#10X1/2"
4" (102mm)
WALL
INTAKE FLEX HOSE
WITH CLAMPS
EXHAUST
INTAKE AIR
MOUNTING PLATE
EXHAUST ELBOW MAY
BE CUT TO LENGTH
TO FIT VENT BOX.
SECURE IN PLACE
USING HOSE CLAMPS
PROVIDED.
KEEP CAP ON
UN-USED AIR
INTAKE OPENING
EXHAUST AIR
ORANGE SILICONE
ELBOW CONNECTOR
INTAKE AIR
BLACK FLEXIBLE HOSE
19563-9-0519Page 12
Venting (Figures 7 and 8)
This unit is vented directly out the back using the concentric
vent tube assembly provided. See Figure 2 for vent hole
location. This hole location can be conveniently moved closer
to unit exhaust outlet tube to avoid wall stud interference if
necessary. The orange silicone exhaust elbow would need
to be cut to length. Do not locate vent directly behind the
exhaust outlet.
The vent provided will accommodate walls up to 10" thick
and can be cut shorter for thinner walls if desired by using a
hacksaw or cut-off saw. Be sure to leave the minimum 3/4"
of tube length extending beyond the outside wall plate. Both
the inner and outer tube will be cut to the same length as the
inner exhaust tube has an extension piece which is added
during nal outside assembly.
Be sure to deburr the ends with a le after cutting. Installation
is easy after cutting the wall opening secure the vent terminal
box in place using the (4) 10 x 1" hex-head screws provided.
Locate the box so that the middle exhaust tube is directed
toward the furnace exhaust outlet opening. See Figure 8.
Attach the black 2" exible inlet air hose to the bottom 2"
connector on the vent box using a hose clamp. Secure the
other end to the lower inlet air box connector using the hose
clamp. Do not kink hose. Attach the long straight end of the
2" orange silicone exhaust elbow to the middle vent terminal
tube and rotate the elbow toward the furnace exhaust outlet.
Secure the hose to the vent box using a hose clamp. Carefully
push the furnace back closer to the wall and secure the
exhaust elbow to the 2" exhaust tube exiting the unit. Secure
the elbow in place using the last remaining hose clamp. The
furnace can now be secured to the wall.
For wall depths thicker than 10" (254mm) order the extended
vent terminal kit which will cover walls to 32" (813mm)
thickness. The vent pipes must be cut to length to assemble
for desired wall thickness. Do not extend venting beyond the
32" maximum length.
Installation of Shroud
To complete inside installation, secure furnace to the wall
bracket by attaching the two wall mounting brackets to the
wall bracket by using (2) 10 x 1/2" (13mm) hex-head screws
provided (See Figures 4 and 6). To attach the right shroud
and left shroud to the casing back, the 3/4" wide ange on
the shroud must be positioned toward the casing side. When
positioned correctly, the (6) louvers on the shroud will be facing
up and the knock-out on the shroud will be facing down. Attach
the right shroud and left shroud to the casing back with (3)
10 x 1/2" hex-head screws supplied in hardware package,
for each shroud. Attach top shroud to right shroud and left
shroud with (4) Phillips-head screws, supplied in hardware
package. Insert air lter into top shroud.
Attention: If the right shroud and left shroud are installed
incorrectly, with the 3/4" wide anges facing inward, the top
shroud will not be able to be installed onto the side shrouds.
The top shroud will appear to be 2 inches, too narrow.
Vent Terminal (Figure 9)
Place the 6 3/8" x 6 3/8" (162mm x 162mm) black foam,
wall plate gasket within the mounting plate. The 4 3/4"
(121mm) diameter hole in the black foam gasket will allow
for installation of the concentric vent tube assembly. Slide the
outside mounting plate into place on the concentric vent tube
assembly. The outside mounting plate should seal against the
face of the building and be secured in place using (4) 10 x 1"
hex-head screws. Be sure to caulk and seal around the pipe
on the exterior using high temperature exterior grade, silicone
caulk rated at 204°C/400°F. Wipe some silicone sealant on
the 2" (51mm) exhaust pipe extension. The end cap can be
pushed into place on the exhaust outlet tube.
Attention: The opening on the bottom of the end cap must
be positioned toward the ground. The opening on the bottom
cannot be pivoted to the right or left, it must be centered
toward the ground.
Figure 9
Reassembly and Resealing Vent-Air Intake System
When vent-air intake system is removed for servicing the
furnace, the following steps will assure proper reassembly
and resealing of the vent-air intake assembly. Be sure all
hose connections are re-secured in place using the hose
clamps removed. Reattach all screws securing mounting
anges and inspect all connections for a tight t. Use high
temperature silicone caulk rated at 204°C/400°F to reseal
the inlet air vent pipe to the mounting plate.
NO. 10X11/2"
SCREWS (4)
INLETAIR
EXHAUST
AIR
12"(305mm)MIN.
ABOVE GRADE
CAULK AROUND PIPE
EXHAUST FITTING-SLIDE ONTO
2" EXHAUST TUBE AND USE RTV
SEALANT TO SECURE IN PLACE
WITH OUTLET POINTED DOWN
AS SHOWN
FURNACE INSTALLATION (CONT'D)
19563-9-0519 Page 13
FOR YOUR SAFETY READ BEFORE OPERATING
A. This appliance does not have a pilot. It is equipped with
an ignition device which automatically lights the burner.
Do not try to light the burner by hand.
B. BEFORE OPERATING smell all around the appliance
area for gas. Be sure to smell next to the oor because
some gas is heavier than air and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the re
department.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it; call a qualied service
technician. Force or attempted repair may result in a
re or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualied service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
1. STOP! Read the safety information above.
2. Set the thermostat to lowest setting.
3. Turn off all electric power to the appliance.
4. This appliance is equipped with an ignition device which
automatically lights the burner. Do not try to light the
burner by hand.
5. Remove control access panel (front panel).
6. Turn gas control knob clockwise to "OFF."
7. Wait ten (10) minutes to clear out any gas. Then smell
for gas, including near the oor. If you smell gas, STOP!
Follow "B" in the safety information above. If you don't
smell gas, go to the next step.
8. Turn gas control knob counterclockwise to
"ON".
9. Replace control access panel (front panel).
10. Turn on all electric power to the appliance.
11. Set thermostat to desired setting.
12. If the appliance will not operate, follow the instructions
"TO TURN OFF GAS TO APPLIANCE" and call your
service technician or gas supplier.
OPERATING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if service is
to be performed .
3. Remove control access panel (front panel).
4. Turn gas control knob clockwise
to "OFF." Do
not force.
5. Replace control access panel (front panel).
TOPVIEW
BACKEND VIEW
GASCONTROLLEVERSHOWN
IN "OFF"POSITION
OFF
CONVERTIBLE
REGULATOR
VINYLCAP
VINYL CAP
CONVERTIBLE
REGULATOR
GAS CONTROL LEVER SHOWN
IN "OFF" POSITION
TOP VIEW
BACK END VIEW
LIGHTING INSTRUCTIONS
WARNING

personal injury or loss of life.
19563-9-0519Page 14
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical
Code, CSA C22.1, if an external electrical source is utilized.
This


directly into a properly grounded three-prong receptacle. Do
not cut or remove the grounding prong from this plug. For an
ungrounded receptacle, an adapter, which has two prongs and a
wire for grounding, can be purchased, plugged into the ungrounded
receptacle and its wire connected to the receptacle mounting screw.
With this wire completing the ground, the appliance cord plug can
be plugged into the adapter and be electrically grounded.
CAUTION: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
NOTE: For testing ame sensor circuit use a micro-amp meter in
series with sensor. Minimum current should be 1 micro-amp during
operation. Be careful as ame sensor is in the 115VAC circuit. If
current is below 1 micro-amp, remove sensor, clean with light
sandpaper and retest.
NOTE: This heater is equipped with a remote bulb electronic
thermistor control located down low at the back of the furnace.
Sometimes due to eld locations different air currents may effect the
control sensing of the thermistor. This sensing bulb can be re-located
if necessary to provided for better room air sensing and control.
Replacement of Thermistor with 24 Volt Wall Thermostat
1. If furnace is installed, turn off gas supply and electric supply.
2. Remove casing front.
3. Remove black hose from front nipple on pressure switch.
4. Remove junction box cover (4 screws).
5. Please refer to wiring diagram for removal of the following
wires.
6.
Internal Electronic Thermostat/Temperature Control Board
Attention! No 24 volt wall thermostat wires are to be
attached to the internal electronic thermostat.
7. Control Board
A. Remove white wire form screw marked W.
B. Remove yellow wire from screw marked C.
C. Remove red wire from screw marked R.
8. Route (2) wires from any 24 volt wall thermostat through the
casing back of furnace to the screws marked W and R on
the control board.
9. Replace junction box cover (4 screws).
10. Replace black hose onto front nipple on pressure switch.
11. Replacement of thermistor with 24 volt wall thermostat is
completed.
CIRCULATING AIR BLOWER
WHT
FS
LS
RED
YEL
RED
BLK
1
PUR
PUR
INDUCER
BLOWER
BLU
BLU
6
5
3
IF ANYOFTHE ORIGINAL WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED
WITHAWIRE OF AT LEAST 105
°
C TEMPERATURE RATING.
LIMIT SWITCH
SECONDARY
FIELD INSTALLED
THERMOSTAT
24 VOLT
115VAC
SWITCH
LIMIT
3A FUSE
GND
BLACK
WHITE
ON/OFF
ROLLOUT
PRESSURE
SWITCH
R-8191
VALVE
GAS
TRANSFORMER
24 VAC
PRIMARY115 VAC
COMMON
DISCONNECT INTEGRAL THERMOSTAT "R", "W", AND "C" LEADS AND ATTACH WALL THERMOSTAT AS SHOWN
RW
5
6
PSROS
RED
GRN
ORG
7
8
9
ORG
ELECTRONIC
THERMOSTAT
INTEGRAL
WHT
YEL
RED
2
3
GRY
BRN
BRN
GV
GRY
24 V
WHT
BLK
115 V
OPTIONAL WALL MOUNT THERMOSTAT
XFMR
ON/OFF
BLACK NEUTRAL
RIBBED
INSULATION
BLACK HOT
SMOOTH
INSULATION
CIRCULATING AIR
BLOWER MOTOR
RED LED
STATUS
LIGHT
IGN
HOT SURFACE
IGNITOR
POWER SWITCH
INDUCER MOTOR
FLAME SENSOR
COMBUSTION AIR
ROS = ROLLOUT LIMIT SWITCH
IGN = HOT SURFACE IGNITOR
PS=PRESSURE SWITCH
XFMR=TRANSFORMER
CORDSET 115VAC
FS=FLAME SENSOR
GV=GAS VALVE
LS=LIMIT SWITCH
4
2
4 1
WIRING
19563-9-0519 Page 15
Proper Main Burner Flame
The proper main burner ame will be a blue primary (inner)
ame with a larger, lighter blue secondary (outer) blue ame.
Figure 10
Cleaning Main Burner(s)
Remove main burner(s) and apply air pressure inside the
throat and ports of the main burner(s).
Removing Main Burner(s)
1. Remove front grill assembly.
2. Remove burner compartment access panel (2 screws).
3. Remove main burner(s) from burner compartment (2
screws per main burner).
Removing Gas Valve
1. Remove front grill assembly.
2. Disconnect manifold union assembly at gas valve.
3. Remove (2) two 24 volt wires from gas valve. Label wires
prior to disconnection from gas valve.
4. Remove gas valve from gas valve bracket.

1. Remove front grill assembly.
2. Remove burner compartment access panel (2 screws).
3. Disconnect manifold union assembly.
4. Disconnect manifold union assembly brackets (5 screws).
Removing Ignitor and Flame Sensor
1. Remove front grill assembly.
2. Remove ignitor from burner compartment (2 screws).
3. Remove ame sensor from burner compartment (1 screw).
Cleaning Combustion (Exchanger) Assembly
A QUALIFIED SERVICE PERSON should remove the
combustion (exchanger) assembly. Apply air pressure to
the inside of the combustion (exchanger) assembly in order
to clear all passageways.
Oiling
The blower motor has an oil hole located on each end of the
motor. Use #20 motor oil only. It is best to oil the motor
several times during the heating season using 2 or 3 drops
MAINTENANCE
19563-9-0519Page 16
Your new furnace should provide many years of trouble free
performance, however, a yearly inspection of the burners ,
ue passageways and the outlet vent assembly should be
done. Be sure all passageways are open and clear of any
obstruction, or soot build up. Be sure to shut off all power to
the unit while performing this inspection.
Periodically remove the circulating air lter and clean with
water to remove all dirt. Shake dry and reinstall in unit.
System Operation
1. This furnace has an electronic thermostat and control
board to monitor the room temperature and then control
the furnace operation to provide the best comfort and
performance from a heating appliance. To operate unit
turn ON/OFF switch to ON and then turn temperature
control knob clockwise slowly till furnace turns on. For
typical room comfort, the control knob should be pointed
toward medium.
2. The furnace control board follows sequence of operation
which allows for self diagnosis in the event there is a
problem. The control then blinks a status light, a set number
of blinks based on what problem has been encountered.
When the furnace is on and there is a no fault condition,
the red LED is on.
On a typical call for heat by the integral thermostat 24
VAC is applied to the W terminal on the board.
The inducer blower circuit is energized and the inducer
blower comes on for 15 seconds pre-purging out any gas
and closing the pressure switch.
The hot surface ignitor is energized and after a 17 second
warm-up, the gas valve circuit is energized, opening the
gas valve and igniting the burners. After burning for about
30 seconds, the circulating air blower comes on, delivering
warm air to the room. If ignition does not occur, the ignition
sequence is repeated again up to 2 more times. (3 trials
for ignition-total)
3. After the furnace operates and satises the thermostat, the
gas valve closes and the circulating air blower continues
to run for about 2 minutes and then shuts off. The inducer
blower runs for 5 seconds and shuts off.
If for any reason ignition and operation does not occur, the
control board will blink the red fault status LED, a sequence
code, indicating what to look for as a troubleshooting guide.
If the red LED is ON but not blinking check the electronic
temperature control to verify its operation. This can be
easily done by disconnecting the 3 electronic temperature
control leads from the main furnace board and using a
pig tail jumper to connect R & W together on the board. If
the furnace comes on and runs normally the temperature
control board is malfunctioning. If the heater still does not
come on, then the main furnace board is malfunctioning.
Look for any fault codes below and verify the 3 amp fuse
is not blown.
OPERATION AND TROUBLESHOOTING
19563-9-0519 Page 17
FURNACE CONTROL BOARD DIAGNOSTICS
FAULT SEQUENCE CODE — Trouble Shooting Guide
 FAULT CONDITION FAULT CORRECTION
Steady On 
1 Flash Temperature limit switch is open
-Check Circulating Air Blower Inlet or Grill Outlet for Blockage,
Inducer Blower/Circulating Air Blower Run to Cool Heat Ex-
changer and Limit
-Check for Flame Roll Out Condition Causing Roll Out Limit
Switch on Burner Box to Open
-Clean Circulating Air Filter
2 Flashes
Pressure switch is open with in-
ducer on
-Check Heat Exchanger and Flue System, Outlet and Inlet for
Restriction
-Check Inducer Blower/Wheel for Operation/Airow
-Check Pressure Switch
3 Flashes
Pressure switch is closed with
inducer off
-Check Pressure Switch and Replace
4 Flashes Lockout due to failed ignition
-Check for Broken Ignitor
-Check for Bent Ignitor Bracket - Ignitor too far from Burner
-Check for Flame Sensor Malfunction/or False Ground
-Check Gas Valve
-Reset Thermostat
5 ashes
L1/Neutral reversed or voltage not
present on L1
-Shut Off Power to Unit and Dis-Connect Cordset Plug from Wall
Receptacle.
Open Junction Box and Un-Reverse Polarity of Incoming Power
Leads
Rapid Flash
Flame sense or internal control
fault
-Check Ignitor Operation
-Check Flame Sensor for Malfunction or False Grounding
-Check Gas Valve
-Reset Thermostat
NOTE: If the hot surface ignitor is to be replaced, be sure to disconnect all power to the unit. Be very careful in handling
the new ignitor as they are fragile and can be broken easily if hit or dropped.
19563-9-0519Page 18
Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through
the distributor. Parts can be shipped directly to the service person/dealer.
All parts listed in the Parts List have a Part Number. When ordering parts, rst obtain the Model Number from the name plate on your
equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the following appropriate il-
lustration and list. Be sure to give all this information.
Furnace Model Number
Part Description
Furnace Serial Number Part Number
Type of Gas (Propane or Natural)
Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store.
Shipments contingent upon strikes, res and all causes beyond our control.
Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, IL 62222-0529
PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide.
HOW TO ORDER REPAIR PARTS
PARTS LIST
INDEX
NO.
PART
NO.
DESCRIPTION
1 DV-1378 SHROUD TOP
2 DV-1376 SHROUD SIDE RIGHT
3 R-2521 AIR FILTER
4 DV-1375 FILTER RETAINER
5 DV-1379 WALL MOUNTING BRACKET
6 DV-1048 WALL BRACKET - 2 REQ
7 R-2586 CONTROL DOOR PIN - 2 REQ
8 19676 CONTROL DOOR ASSEMBLY
9 DV-1373 CASING TOP
10 R-2661 BLOWER HOUSING - 2 REQUIRED
11 R-2663 BLOWER WHEEL - 2 REQ
12 R-2662 BLOWER MOTOR
13 R-2598 MOTOR BASE WASHER - 4 REQ
14 R-1279 LIMIT SWITCH
15 DV-1367 INNER TOP
16 R-2546 CONTROL KNOB
17 R-2522 ON/OFF SWITCH
18 19561 JUNCTION BOX
19 DV-1370 JUNCTION BOX COVER
20 R-1995 TRANSFORMER
21 R-6988 PRESSURE SWITCH
22 R-8140 CONTROL BOARD
23 R-2577A TEMPERATURE CONTROL BOARD
24 DV-1365 CASING WELDED ASSEMBLY
25 R-1468 STRAIN RELIEF BUSHING
26 R-2099 CORD SET
27 DV-1371 INNER END
28 DV-1372 CASING SIDE - 2 REQUIRED
29 DV-1163 COLLECTOR BOX
30 R-2519 INDUCER WHEEL
31 DV-1169 INDUCER BLOWER HOUSING ASSEMBLY
32 R-2523 INDUCER MOTOR
33 15785 EXCHANGER ASSEMBLY
34 27523 IGNITOR KIT
37 R-2543 FLAME SENSOR
38 R-12593 BURNER - 3 REQ
39 R-2575 FLAME ROLLOUT SWITCH
40 DV-1038 BURNER COMPARTMENT ACCESS PANEL
41 DV-1143 BURNER COMPARTMENT
42 R-3237 GAS VALVE - NATURAL
42 R-3238 GAS VALVE - PROPANE
43 DV-1366 VALVE BRACKET
44 DV-1147 MANIFOLD ASSEMBLY
45 P-88-1.20MM ORIFICE (PROPANE GAS) - 3 REQ
45 P-88-47 ORIFICE (NATURAL GAS) - 3 REQ
46 M-148 MANIFOLD GASKET
47 DV-781 OBSERVATION HOLE COVER ASSEMBLY
48 M-155 OBSERVATION HOLE COVER GASKET
49 15792 FRONT SHIELD ASSEMBLY
50 DV-1024 BOTTOM SHIELD
51 DV-1364 FRONT GRILL ASSEMBLY
52 DV-1380 CASING FRONT ASSEMBLY
53 R-2539 HOSE CLAMP - 4 REQ
54 R-3113 INLET HOSE
55 R-3111 OUTLET ELBOW
56 DV-1192 VENT PAN ASSEMBLY
57 R-3114 INLET CAP
58 R-3115 WALL PLATE GASKET - INSIDE
59 R-2587 WALL PLATE GASKET - OUTSIDE
60 DV-1195 WALL PLATE - OUTSIDE
61 DV-1193 TUBE SPACER
62 DV-1194 END CAP ASSEMBLY
63 DV-1377 SHROUD SIDE LEFT
NS R-8142
WIRE ASSEMBLY - CONTROL BOARD 5 PIN
NS R-2563
WIRE ASSEMBLY - CONTROL BOARD 9 PIN
INDEX
NO.
PART
NO.
DESCRIPTION
19563-9-0519 Page 19
PARTS VIEW
19563-9-0519Page 20
www.empirecomfort.com
Empire Comfort Systems Inc.
Belleville, IL
If you have a general question
about our products, please e-mail
If you have a service or repair
question, please contact your dealer.
WARRANTY
Empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for the periods
specied below. Space heating products must be installed by a qualied technician and must be maintained and operated safely, in
accordance with the instructions in the owner’s manual. This warranty applies to the original purchaser only and is not transferable.
All warranty repairs must be accomplished by a qualied gas appliance technician.
Limited Ten-Year Parts Warranty – Combustion Chamber
Empire promises to the owner that if the combustion chamber (see parts list) fails because of defective workmanship or
material with ten years from the date of purchase, Empire will repair or replace at Empire’s option.
Limited One-Year Parts Warranty – Remote Controls, Thermostats, Accessories, and Parts
Should any remote control, thermostat, accessory, or other part fail because of defective workmanship within one year from
the date of purchase, Empire will repair or replace at Empire’s option.
Duties Of The Owner
The appliance must be installed by a qualied installer and operated in accordance with the instructions furnished with the
`appliance. A bill of sale, cancelled check, or payment record should be kept to verify purchase date and establish
warranty period. Ready access to the appliance for service.
What Is Not Covered
Damages that might result from the use, misuse, or improper installation of this appliance.
Travel, diagnostic costs and freight charges on warranted parts to and from the factory.
Claims that do not involve defective workmanship or materials.
Unauthorized service or parts replacements.
Removal and reinstallation cost.
Inoperable due to improper or lack of maintenance.
How To Get Service
To make a claim under this warranty, please have your receipt available and contact your installing dealer. Provide the dealer
with the model number, serial number, type of gas, and purchase verication. The installing dealer is responsible for providing
service and will contact the factory to initiate any warranted parts replacements. Empire will make replacement parts available
at the factory. Shipping expenses are not covered.
If, after contacting your Empire dealer, service received has not been satisfactory, contact: Consumer Relations Department,
Empire Comfort Systems Inc., PO Box 529, Belleville, Illinois 62222, or send an e-mail to [email protected] with
“Consumer Relations” in the subject line.
Your Rights Under State Law
This warranty gives your specic legal rights, and you may also have other rights, which vary from state to state.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Empire Heating Systems DV55E Le manuel du propriétaire

Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues