Kessil A80 Mode d'emploi

Taper
Mode d'emploi

Ce manuel convient également à

INSTALLATION GUIDE
PARTS DIAGRAM
A80
PRODUCT SPECIFICATIONS
Illuminator
Listed Power Supply
Power Consumption 15W maximum
24VDCInput Voltage
Input
Output
100-240VAC, 50-60Hz
24VDC, maximum 1A
SAFETY INSTRUCTIONS
1. DO NOT use a power supply that does
not meet the specifications. This is a fire
hazard and may lead to unit failure.
2. DO NOT use outdoors. This unit is
intended for indoor use only.
3. DO NOT expose unit to an extremely
humid environment or submerge in
water. This may lead to unit failure.
4. DO NOT place unit in close contact with
any other objects while powered on
because unit may overheat.
5. KEEP lens (E) away from sharp objects.
This may break the lens and lead to unit
failure.
6. DO NOT cover or place objects on the
power supply (G). It should not be
contained in an airtight space.
INSTRUCTIONS DE SECURITE
1. N'UTILISEZ PAS d'adaptateur
d'alimentation qui ne satisfait pas aux
exigences. Il y aurait un risque d’incendie
et de dommages de l’unité.
2. NE PAS UTILISER à l’extérieur. Cette
unité est prévue pour une utilisation en
intérieur.
3. N’EXPOSEZ PAS l’unité à un
environnement extrêmement humide ou
ne submergez pas l’unité dans l’eau. Cela
pourrait endommager l’unité.
4. NE PLACEZ PAS l’illuminateur en
marche, en contact direct avec d’autres
objets. Cela pourrait causer un
réchauffement trop élevé de ces derniers
et pourrait faire surchauffer l’unité.
5. GARDEZ la lentille (E) à l‘écart des objets
pointus. Les objets pointus pourraient
casser la lentille et endommager l’unité.
6. NE RECOUVREZ PAS, ou ne placez pas
d’objet sur l'adaptateur d'alimentation (G).
Il ne doit pas se trouver dans un espace
fermé.
This is a LED light source emitting 40 % or more of total radiation
power of the range 250-800 nm in the range of 400-480 nm, and
intended for coral growth.
1. Remove contents from package.
2. Hang the A80 1 to 2 ft. above the
plants/tank.
3. Connect Power Cord (A) to the
specified DC Power Supply (G).
4. Plug the power supply into an outlet
with the correct specifications (see
product specifications for more
information).
5. Using the A80's Intensity Tuning Dial
(F) and Spectrum Tuning Dial (B), set
the light to the desired setting. A80
Tuna Blue tunes from 10,000K -
Actinic. A80 Tuna Sun tunes from
6,000K - 9,000K.
6. The ports beneath the dials can be
connected to an external 0~10V
controller. Please consult your
controller's owner's manual for more
information.
A
B
F
D
A. Power Cord
B. Spectrum Tuning Dial
C. 0-10V Controller Ports
D. Heat Sink Fin
E. Lens
F. Intensity Dial
G. DC Power Supply
C
G
OWNER’S MANUAL
LED ILLUMINATOR
EA DiCon Brand
ver. A2
@kessilled
@kessil
kessil.com
kessiltube
kessil.led
To next light Input from Controller
Intensity DialUnit Link Cable
Spectrum Tuning Dial
TROUBLESHOOTING GUIDE
Problem
Light doesn’t turn ON
Unit is flickering
Solution
Make sure the unit is connected to the power supply and the power
supply is connected to an outlet with the correct specifications.
Make sure you are using a power supply with the correct specifications.
Make sure to operate the unit in a room at 104°F / 40°C or lower to
prevent overheating.
Make sure electrical power is available to the AC outlet being used.
Make sure the power supply has the right specifications.
Make sure the device is operating within the specified operating
temperature range (below 104°F or 40°C). If the unit overheats, it will
automatically shut down.
Controllability
Multiple A80 lights can be controlled either manually or by
a single external 0-10V controller.
MAINTENANCE
1. Keep the unit clear of dust. To clean, unplug the unit and use a clean, dry cloth to
remove accumulated dust from between each Heat Sink Fin (D).
2. Keep the Lens (E) clean. If the lens becomes contaminated with water, dust, or other
particles, unplug the unit and clean the lens with isopropyl alcohol. Wet a cotton swab
or a napkin in isopropyl alcohol, gently wipe the surface of the lens and let dry.
CABLES
Available cables:
Control Cable (Please consult kessil.com
for list of available cables and compatible
controllers).
• Unit Link Cable (male/male with 3.5 mm
stereo jack).
• Control Extension Cable (6' male/female
with 3.5 mm stereo jack).
STARTING A CHAIN
Connect two or more lights with the Unit
Link Cable, as shown above.
CONTROL METHODS
There are two ways to control a chain of lights:
1. With an external controller.
2. Without external controller (Tuning Dials on
the first light control all other lights in chain).
Each light has its own independent power
supply. Any number of lights can be daisy
chained together without degradation of
signal. However, in longer chains a slight
delay in response may occur. Manual tuning
is disabled when input cable is plugged in.
Optional Accessories
For other accessories, please visit www.kessil.com.
Remove the two screws on the back of A80,
and use them to secure Top Mounting Adapter
(H) to A80, then use two wood screws (I) to
mount them.
Top Mounting Adapter
A80 Gooseneck
(L=10 in)
H
I
  • Page 1 1
  • Page 2 2

Kessil A80 Mode d'emploi

Taper
Mode d'emploi
Ce manuel convient également à

dans d''autres langues