UEi HUB6 Le manuel du propriétaire

Taper
Le manuel du propriétaire

Ce manuel convient également à

INSTRUCTION MANUAL
ENGLISH
Smart Temperature Split Kit
Smart Refrigerant Charging Kit
Smart Refrigerant Complete Kit
1-800-547-5740
www.ueitest.com • email: [email protected]
HUB2 / HUB4 / HUB6
WPP1
Wireless Pressure
Probe
Power
Lo-Bat
WPP1
Wireless Pressure
Probe
Power
Lo-Bat
WHP1
Wireless
Hygrometer Probe
WHP1: Wireless Hygrometer Probe
WPP1: Wireless Pressure Probe
WPC1: Pipe clamp sensor
UEI HUB APP
WARNING
Read entire safety notes section regarding potential hazard and proper
instructions before using these probes. In this manual the word “WARNING
is used to indicate conditions or actions that may pose physical hazards to
the user. The word “CAUTION” is used to indicate conditions or actions that
may damage these instrument.
WARNING
To ensure safe operation and service of these probes, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
WARNING
Maximum over pressure is: 1000 PSI.
WARNING
• Do not open these probes to replace batteries while the probes
are connected to an HVACR or other mechanical system.
• To avoid false readings, replace batteries if a low battery indicator appears.
• Do not use this these probes if they appear damaged.
• Always adhere to national and local safety codes. Use proper personal
protective equipment (PPE).
WARNING
These probes are designed for trade professionals who are familiar with the
hazards of their trade. Observe all recommended safety procedures that
include proper lockout utilization and use of personal protective equipment
that includes safety glasses, gloves and flame resistant clothing.
HUB2
2 WHP1
4
Batteries
(AAA)
Carrying case
HUB4
2 WPP1
2 WPC1
4 Batteries (AA)
Carrying case
HUB6
2 WHP1
2 WPP1
2 WPC1
8 Batteries
(4x AA, 4x AAA)
Carrying case
IMPORTANT SAFETY WARNINGS
1. Hygrometer (WHP1): Hub 2 & Hub 6
A. Lock Button: Press to open or close probe
B. 1/4” diameter probe.
C. Magnetic Mount
D. Battery Cover.
E. Light: Blinks GREEN when probe is powered
on. Blinks RED when low battery.*
CAUTION: Press down Lock Button to
release probe. Failure to do so may break probe
and is not covered under warranty.
GENERAL SPECIFICATIONS
Temperature Range: 32˚F to 140˚F (0˚C to 60˚C)
Temperature Accuracy: ±0.5˚F (0.3˚C)
Relative Humidity Range: 0% to 100%
Relative Humidity Resolution: 0.1%
Relative Humidity Accuracy: ±3% 20% to 80%
otherwise ±5%
Operating Temperature: 41°F to 140°F (5°C to 60°C)
Storage Temperature: 14°F to 140°F (-10°C to 60°C)
Operating Humidity: 20% RH to 80% RH
Recommended: Do Not use longer than 60
hours out of range
Dimensions: 6.84 in x 1.93 in x 1.53 in
(17.4 cm x 4.9 cm x 3.9 cm)
Item Weight: 4.4 oz (125 gr)
Certification: CE Conformity, FCC/IC
Battery Type: (AAA) 2
Battery Life: 100+ hours
* NOTE: Low battery indicator is also in the
“Tool Connection” screen
WHP1 OVERVIEW
WHP1
Wireless
Hygrometer Probe
WHP1
Wireless
Hygrometer Probe
B.
A.
C.
E.
D.
Remove battery cover.
Replace the old batteries with 2 new
(AAA) batteries.
Replace the battery cover.
Battery level are displayed in the
tool connection screen to the right of each
probe connected.
Caution: Take care not to lose the screws when
opening battery compartments
2. Pressure Probe (WPP1): Hub 4 & Hub 6
A. Cable connector plug-in: for connecting the
pipe clamp sensor (WPC1).
B. Battery cover
C. Light: Blinks GREEN when probe is powered
on and blinks RED when low battery.*
D. Power Button: Hold for one second to
power on
E. 1/4”pressure connector
F. 1/4” pass-through connector
*NOTE: Low battery indicator is in the “Tool
Connection” screen
GENERAL SPECIFICATIONS
Range: 0 to 725 PSIg
Resolution: 0.1 PSI
Accuracy: 0.5% F.S. (at 25˚C ±3˚C) Total 1% F.S.
32˚F to 158˚F (0˚C to 70˚C)
Operating Temperature: 14°F to 158°F
(-10°C to 70°C)
Storage Temperature: 14°F to 140°F
(-10°C to 60°C)
Operating Humidity: 30% RH to 85% RH
Over-range: 1000 PSI
Dimensions: 6.70 in x 1.56 in x 1.44 in
(17 cm x 4 cm x 3.7 cm)
Item Weight: 7.4 oz (210 gr)
Certification: CE Conformity, FCC/IC
Battery Type: (AA) 2
Battery Life: 100+ hours
3. Pipe clamp sensor (WPC1): Hub 4 & Hub 6
A. Temperature sensor
B. Cable connector plug-in: for connecting
WPC1 to the WPP1.
NOTE: Maximum pipe diameter is 1.5 in. (3.8cm)
GENERAL SPECIFICATIONS
Range: 32˚F to 176˚F (0˚C to 80˚C)
Resolution: 0.1˚F
Accuracy: ±(0.6˚F (0.3˚C))
Response Time: <30 sec.
Operating Temperature: -40°F to 185°F
(-40°C to 85°C)
Storage Temperature: 14°F to 140°F (-10°C to 60°C)
Dimensions: 5.66 in x 3.81 in x 1.10 in
(14.4 cm x 9.7 cm x 2.8 cm)
Item Weight: 2.1 oz (60 gr)
Certification: CE Conformity, FCC/IC
A. Home Screen:
Refrigerant Side
A. Home Screen:
Air Side
UEi HUB OVERVIEW
B.
A.
A.
B.
C.
D.
E.
F.
WPP1 OVERVIEW
WPC1 OVERVIEW
A. Suction Line Pressure
B. Suction Line Temperature
C. Refrigerant Favorites (tap to view)
D. Liquid Line Pressure
E. Liquid Line Temperature
F. Refrigerant List (tap to view)
G. Air Side Screen (tap or swipe
left to view)
H. Vapor Saturation Temperature
I. Liquid Saturation Temperature
A. Refrigerant Side Screen (tap or
swipe right to view)
B. Delta T
C. Target Delta T (assumes
400 CFM/ton)
D. Return Dry Bulb Temperature
E. Return Wet Bulb Temperature
F. Return and Supply Calculations
(tap to view)
G. Supply Dry Bulb Temperature
H. Supply Wet Bulb Temperature
Hub
Refrigerant Side Air Side
Line Pressure
Line Temp
select tool
select tool
Suction
--.--°F
Vapor
Saturation
--.--°F
Superheat
Line Pressure
Line Temp
select tool
select tool
Liquid
--.--°F
Liquid
Saturation
--.--°F
Subcooling
R507A
Hub
Refrigerant Side Air Side
Line Pressure
Line Temp
select tool
select tool
Suction
--.--°F
Vapor
Saturation
--.--°F
Superheat
Line Pressure
Line Temp
select tool
select tool
Liquid
--.--°F
Liquid
Saturation
--.--°F
Subcooling
R507A
A.
F.
G.
I.
H.
B.
C.
D.
E.
Hub
Refrigerant Side Air Side
--.--°F
Delta T
--.--°F
Target Delta T
Supply Dry Bulb
Supply Wet Bulb
select tool
select tool
Return Dry Bulb
Return Wet Bulb
select tool
select tool
G.
F.
B.
A.
C.
D.
E.
H.
• Remove battery cover.
Replace the old batteries with 2 new
(AA) batteries.
• Replace the battery cover.
Battery level are displayed in the tool
connection screen to the right of each
probe connected.
Caution: Take care not to lose the screws when
opening battery compartments
Hub
Refrigerant Side Air Side
Line Pressure
Line Temp
select tool
select tool
Suction
--.--°F
Vapor
Saturation
--.--°F
Superheat
Line Pressure
Line Temp
select tool
select tool
Liquid
--.--°F
Liquid
Saturation
--.--°F
Subcooling
R507A
Units
Pressure
Temperature
Enthalpy
Altitude Compensation
Elevation
Units
PSI
°F
btu/lb
1
ft
bar
KPa
°C
Kj/Kg
ft
m
MPa
R11
R12
R13
R22
R23
R113
R114
R123
R1234YF
R124
R125
R134A
R401A (MP39)
R401B
R402A
R402B
R404A
R406A
R407A
R407C
R407F
R408A
R409A
R410A
R414B (Hotshot)
R416A
R417A
R417C (Hotshot 2)
R420A
R421A
R421B
R422A
R422B(NU22B)
R422C (Oneshot)
R422D
R424A
R427A
R434A (RS-45)
R438 (MO99)
R500
R502
R503
R507A
R508B (Suva95)
Refrigerant List: Tap to activate.
Tap stars to add/remove favorites.
B. Units Screen
C. Tool Connection Screen
D. User Info Screen
Refrigerant Favorites Button: displays selected favorites for quick changes.
Tool Connection
Refrigerant Side
Suction
Liquid
Air Side
Nearby Tools
Return
Supply
No tools available
WHP1 70.7 °F
WPP1 215.1 PSI
Drag tool here
Drag tool here
Tool Connection
Refrigerant Side
Suction
Liquid
Air Side
Nearby Tools
Return
Supply
No tools available
WHP1 70.7 °F
WPP1 215.1 PSI
Drag tool here
Drag tool here
User Info
Enter email address
Enter name
Enter phone number
Save
User Info
Enter email address
Enter name
Enter phone number
Save
A.
D.
E.
F.
B.
C.
Units
Pressure
Temperature
Enthalpy
Altitude Compensation
Elevation
Units
PSI
°F
btu/lb
1
ft
bar
KPa
°C
Kj/Kg
ft
m
MPa
B.
A.
C.
D.
E.
A. Pressure Units
B. Temperature Units
C. Enthalpy Units
D. Elevation
E. Units
A. Tool Assigned
B. Forget Tool
C. Tool found but not assigned
D. Battery Level
E. Signal Strength
F. Refresh nearby tools
Tap to select or enter units
Refrigerants
R22
R11
R12
R13
R22
R23
R114
R113
R123
FavoritesSelect
A. Home Screen:
Hub
Refrigerant Side Air Side
Line Pressure
Line Temp
select tool
select tool
Suction
--.--°F
Vapor
Saturation
--.--°F
Superheat
Line Pressure
Line Temp
select tool
select tool
Liquid
--.--°F
Liquid
Saturation
--.--°F
Subcooling
R507A
E. Support Screen
Support
UEitest.com
18005475740
Find a store!
Manual
Support
UEitest.com
18005475740
Find a store!
Manual
A.
B.
C.
D.
A. Contacts
B. Manual
(English, Spanish and French)
C. Find a distributor
@UEitest.com
D. Tap to view Features +
Benefits Video
Caution: This symbol indicates that equipment and its accessories shall
be subject to separate collection and correct disposal.
DISPOSAL
CLEANING
STORAGE
WARRANTY
Periodically clean your probe using a damp cloth. DO NOT use abrasive, flammable
liquids, cleaning solvents, or strong detergents as they may damage the finish,
impair safety, or affect the reliability of the structural components.
Remove the batteries when instrument is not in use for a prolonged period
of time. Do not expose to high temperatures or humidity. After a period of
storage in extreme conditions exceeding the limits mentioned in the General
Specifications section, allow the instrument to return to normal operating
conditions before using it.
The HUB is warranted to be free from defects in materials and workmanship
for a period of 1 year from the date of purchase. If within the warranty
period your instrument should become inoperative from such defects, the
unit will be repaired or replaced at UEi’s option. This warranty covers
normal use and does not cover damage which occurs in shipment or failure
which results from alteration, tampering, accident, misuse, abuse, neglect or
improper maintenance. Batteries and consequential damage resulting from
failed batteries are not covered by warranty.
Any implied warranties, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited to the express
warranty. UEi shall not be liable for loss of use of the instrument or other
incidental or consequential damages, expenses, or economic loss, or for any
claim or claims for such damage, expenses or economic loss.
Warranty only covers hardware and does not extend to software applications.
A purchase receipt or other proof of original purchase date will be required
before warranty repairs will be rendered. Instruments out of warranty will be
repaired (when repairable) for a service charge
For more information on warranty and service, contact:
www.ueitest.com Email: [email protected]
1-800-547-5740
This warranty gives you specific legal rights. You may also have other rights,
which vary from state to state.
Copyright © 2018 Kane USA Inc. All Rights Reserved. 17500 01/18
FCC and IC STATEMENT
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC/IC RSS102 radiation exposure limits set forth for an
uncontrolled environment.
This device complies with Industry Canada license-exempt RSS standard(s). Operation
is subject to the following two conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.
Under Industry Canada regulations, this radio transmitter may only operate using
an antenna of a type and maximum (or lesser) gain approved for the transmitter by
Industry Canada. To reduce potential radio interference to other users, the antenna
type and its gain should be so chosen that the equivalent isotropically radiated power
(e.i.r.p.) is not more than that necessary for successful communication.
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut
fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé
pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et
son gain de sorte que la puissance isotrope rayonée équivalente (p.i.r.e.) ne dépasse
pas l’intensité nécessaire à l’établissement d’une communication satisfaisante.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux
appareils radio exempts de licence. L’exploitation est autoris é e aux deux conditions
suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de
l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
FCC AND IC NOTICE
This device complies with Part 15 of the FCC rules and Industry Canada license-
exempt RSS 247. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference; and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC, ainsi qu’à la norme
RSS 247 exempte de licence d’Industrie Canada. Son fonctionnement est soumis aux
deux conditions suivantes : (1) Cet appareil ne doit pas provoquer d’interférences
nuisibles; et (2) cet appareil doit accepter toutes les interférences reçues, y compris
celles susceptibles d’entraîner un dysfonctionnement de l’appareil.
FCC CAUTION
The device must not be co-located or operated in conjunction with any other
antenna or transmitter.
Caution the user that changes or modifications not expressly approved by the party
responsible
for compliance could void the user’s authority to operate the equipment.
L’appareil ne doit pas être placé ou utilisé conjointement avec une autre antenne ou un
autre émetteur.
Attention à l’utilisateur que des changements ou des modifications non
expressément approuvés par la partie responsable pour la conformité pourrait
annuler l’autorité de l’utilisateur pour faire fonctionner l’équipement.
a.The device should be installed and operated with a minimum distance of 20cm
between the radiator and your body.
L’appareil doit être installé et utilisé avec une distance minimale de 20 cm entre le
radiateu et votre corps.
b.This device complies with RSS247 of Industry Canada. Cet appareil se conforme à
RSS247 de Canada d’Industrie. This device complies with Industry Canada license-
exempt RSS standard(s). Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
appareils radio exempts de licence. Son fonctionnement est sujet aux deux
conditions suivantes: (1) le dispositif ne doit pas produire de brouillage
prejudiciable, et (2) ce dispositif doit accepter tout brouillage recu, y compris
un brouillage susceptible de provoquer un fonctionnement indesirable.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme a la norme NMB-003 du Canada.
FCC/IC INFORMATION
C. Find a distributor
@UEitest.com
D. Tap to view Features +
Benefits Video
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

UEi HUB6 Le manuel du propriétaire

Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues