Real Fyre GR47 Le manuel du propriétaire

Catégorie
Cheminées
Taper
Le manuel du propriétaire

Ce manuel convient également à

1
REV 0 -A - 2004290720
L-A2-458
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746 Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746 Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
This gas log set is to be installed only in a solid-fuel
burning fireplace with a working flue and constructed
of noncombustible material. The installation, including
provisions for combustion and ventilation air must
conform with the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, or the CSA B149.1, Natural Gas and Propane
Installation Code, and applicable local building codes.
A damper clamp, which must be permanently installed,
is included to maintain the minimum permanent vent
opening and to prevent full closure of the damper.
The chimney damper MUST be fully opened when
burning the unit. The unit is designed to burn
with yellow flames; thus adequate ventilation is
absolutely necessary.
To comply with certification, listings, and building
code acceptances, and for safe operation and proper
performance of this gas log set, you must use ONLY
Peterson Real Fyre parts, decorative media, and
accessories. Use of any other controls, parts, or
accessories not designed for use with Real Fyre gas
log sets is prohibited. This will void all warranties,
certifications, listings, and building code approvals,
and may cause property damage, personal injury, or
loss of life. Peterson will not be liable for any damages
caused by this misuse.
*Note: Solid-fuels shall not be burned in a fireplace
where this product is installed.
FOR INSTALLATION IN
SOLID-FUEL BURNING
FIREPLACES*
IMPORTANT: READ THESE INSTRUCTIONS
CAREFULLY BEFORE STARTING
INSTALLATION OF THE UNIT.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Open a window.
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in the building.
Immediately call the gas supplier
from a neighbor’s phone. Follow gas
supplier’s instructions.
If you cannot reach the gas supplier,
call the fire department.
WARNING
If the information in this manual is not
followed exactly, a fire or explosion
may result, causing property damage,
personal injury, or loss of life.
This appliance is only for use with the type
of gas indicated on the rating plate.
Installation and service must be
performed by a qualified professional
service technician, service agency, or
the gas supplier.
DESIGN CERTIFIED
to
Vented Decorative Appliance
ANSI Z21.60
CSA 2.26
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
INSTALLATION &
OWNER’S MANUAL
GR47 RUMFORD VENTED GAS LOG SETS
Burner Systems:
GR47- ** (P)A
GR47- ** -02(M)(P)
GR47- ** -17(M)(P)
**Sizes:
(18/20, 24/30)
Regulated burner system for
use w/ propane or natural gas
2
REV 0 -A - 2004290720
L-A2-458
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746 Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746 Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
Le Real Fyre système de brûleur doit être installée
seulement dans une cheminée brûlante de combustible
solide avec une conduite de cheminée fonctionnante
et être construit avec du matériel non-combustible.
L'installation, y compris des dispositions pour l'air de
combustion et de ventilation doit se conformer au code
national de gaz de carburant, la norme ANSI Z223.1/
NFPA 54, ou le CSA B149.1, code d'installation de gaz
naturel et de propane, et codes du bâtiment locaux
applicables.
Une bride plus humide est incluse pour maintenir
l’ouverture permanente minimum de passage et pour
empêcher la pleine fermeture de la lame plus humide.
L'amortisseur de cheminée DOIT être entièrement
ouvert en brûlant l'unité. L'unité est conçue pour
brûler avec les flammes jaunes; ainsi à ventilation
proportionnée est absolument nécessaire.
Pour être en conformité avec la certification, les listes et
les acceptations du code du bâtiment, ainsi que pour un
fonctionnement en toute sécurité et des performances
correctes, vous devez utiliser UNIQUEMENT les pièces,
les supports de décoration et les accessoires Peterson
Real Fyre. L'utilisation d'autres contrôles, de pièces
ou accessoires non conçu pour une utilisation avec
les systèmes de brûleurs Real Fyre est interdite. Ceci
annulera toutes les garanties, les certifications, les
annonces et les approbations du code du bâtiment, et
peut causer des dommages matériels, des blessures
ou des pertes de vie. Peterson ne sera pas responsable
des dommages causés par ce détournement.
*Note: des Plein-carburants ne seront pas brûlés
dans une cheminée où un appareil décoratif
est installé.
POUR L'INSTALLATION DANS
LE COMBUSTIBLE SOLIDE DE
BRÛLANT FIREPLACES*
Ne stockez pas ou n’employez pas l’essence
ou d’autres vapeurs et liquides inflammables
à proximité de ceci ou d’aucun autre appareil.
CE QUI À FAIRE SI VOUS SENTEZ LE GAZ:
Ouvrez une fenêtre.
N’essayez pas de n’allumer aucun appareil.
Ne touchez aucun commutateur
électrique; n’utilisez aucun téléphone
dans le bâtiment.
Appelez immédiatement le fournisseur
de gaz du téléphone du voisin. Suivez les
instructions du fournisseur de gaz.
Si vous ne pouvez pas atteindre le
fournisseur de gaz, appelez le
département de feu.
AVERTISSEMENT
Si l’information en ce manuel n’est pas suivie
exactement, une incendie ou une explosion
peut résulter, entraînant des dégats
matériels, des blessures, ou la perte de la vie.
Cet appareil sert seulement avec le type de
gaz indiqué de la plaque de contrôle.
Installation et entretien doivent être effectués par
un technicien professionnel qualifié de service, un
organisme de service ou le fournisseur de gaz.
CONCEPTION CERTIFIÉE
à
Vented Decorative Appliance
ANSI Z21.60
CSA 2.26
INSTALLATEUR :
Laissez ce manuel avec l'appareil.
CONSOMMATEUR:
Maintenez ce manuel pour la future référence.
IMPORTANT: LISEZ CES INSTRUCTIONS
SOIGNEUSEMENT AVANT DE
COMMENCER L'INSTALLATION DE
L'UNITÉ.
Système de brûleur réglementé
l'usage du propane ou du gaz naturel
INSTALLATION ET
MODE D'EMPLOI
GR47 RUMFORD VENTILÉ SYSTÈMES DE BRÛLEURS
Systèmes de brûleur:
GR47- ** (P)A
GR47- ** -02(M)(P)
GR47- ** -17(M)(P)
**Tailles:
(18/20, 24/30)
3
REV 0 -A - 2004290720
L-A2-458
TABLE OF CONTENTS
GETTING STARTED
IMPORTANT PRE-INSTALLATION AND FIREPLACE
SAFETY INFORMATION ����������������������������������������������� 5
FIREPLACE OPERATING SAFETY INFORMATION ������ 7
SPECIFICATIONS����������������������������������������������������������� 8
DAMPER CLAMP INSTRUCTIONS ����������������������������� 11
GR47 BURNER PARTS LIST - MANUAL (A) SERIES ���12
GR47 BURNER PARTS LIST - 02 SERIES ��������������������� 13
GR47 BURNER PARTS LIST - 17 SERIES ��������������������� 14
INSTALLATION
INSTALLATION �����������������������������������������������������������15
INSTALL BURNER ���������������������������������������������������15
INSTALL BATTERIES (if applicable) ����������������������������15
INSTALL REMOTE RECEIVER / SWITCH BOX (if
applicable) �������������������������������������������������������������� 16
PLACE WIRE GUARD (if applicable) ��������������������������� 16
PREPARE GRATE AND CENTER �������������������������������� 17
HEAT SHIELD PLACEMENT �������������������������������������18
LIGHTING TEST ������������������������������������������������������18
LAVA GRANULES/COALS (optional) ���������������������������18
SAND/VERMICULITE PLACEMENT ���������������������������19
BLACK EMBERS PLACEMENT ���������������������������������� 19
GRATE PLACEMENT �����������������������������������������������20
LOG SET PLACEMENT��������������������������������������������� 22
INSTALLING/REPLACING BATTERIES (if applicable)23
REMOTE TRANSMITTER BATTERY ���������������������������� 23
RECEIVER/BURNER SYSTEM BATTERIES �������������������23
NOTES PAGE ���������������������������������������������������������������24
USE, CARE, & SERVICE
LIGHTING INSTRUCTIONS - MANUAL (A) SERIES ���25
FOR YOUR SAFETY, READ BEFORE LIGHTING ����������25
LIGHTING THE PILOT ���������������������������������������������25
LIGHTING THE BURNER �����������������������������������������27
SHUTTING DOWN ���������������������������������������������������27
PILOT BURNER CHECK/ADJUSTMENT ���������������������27
LIGHTING INSTRUCTIONS - 02 SERIES ���������������������29
FOR YOUR SAFETY, READ BEFORE LIGHTING ����������29
REMOTE LIGHTING (if equipped) ������������������������������29
MANUAL LIGHTING ������������������������������������������������ 31
SHUTTING DOWN ���������������������������������������������������31
LIGHTING INSTRUCTIONS - 17 SERIES ���������������������33
FOR YOUR SAFETY, READ BEFORE LIGHTING ����������33
LIGHTING THE PILOT ���������������������������������������������33
REMOTE LIGHTING (if equipped) ������������������������������33
MANUAL LIGHTING ������������������������������������������������ 35
SHUTTING DOWN ���������������������������������������������������37
PILOT BURNER CHECK/ADJUSTMENT ���������������������37
REMOTE OPERATING INSTRUCTIONS - 17 SERIES �� 37
ORIENTATION ��������������������������������������������������������37
FLAME HEIGHT �����������������������������������������������������37
CLEANING AND SERVICING �������������������������������������� 39
SYNCING THE REMOTE SYSTEM (if applicable) �����������40
FLAME DESCRIPTION ������������������������������������������������40
TROUBLESHOOTING ��������������������������������������������������41
ELECTRONIC PILOT TROUBLESHOOTING (IF
APPLICABLE) ��������������������������������������������������������������43
WARRANTY ���������������������������������������������������������������� 44
4
L'INFORMATION DE SÛRETÉ IMPORTANTE DE PRÉINSTALLATION ET DE CHEMINÉE
A. FAITES ATTENTION: Sinon installé, entretenu, et utilisé correctement par ces instructions, ce produit peut causer le
dommage corporel, les dégats matériels, ou les pertes humaines sérieux.
B. AVERTISSEMENT: Quand l'installation dans une cheminée plein-carburant-brûlante, la conduite de cheminée, l'amortisseur,
et le foyer de cheminée doivent ÊTRE COMPLÈTEMENT NETTOYÉS de la suie, de la créosote, des cendres, et de la peinture
lâche, et doivent être inspectés par un décapant qualifié de cheminée. Quelques cheminées plus anciennes peuvent ont besoin
de réparation avant d'installer cet appareil.
C. Le plancher du foyer doit être plat et lisse.
D. Cet appareil sert seulement avec le type de gaz indiqué de la plaque de contrôle. Cet appareil n'est pas CONVERTIBLE de
CHAMP pour l'usage avec d'autres gaz.
VÉRIFIEZ LE TYPE de GAZ (normal ou propane) : La fourniture de gaz doit être identique qu'indiquée de votre plaque de
contrôle de système de brûleur. Si la fourniture de gaz est différente, N'INSTALLEZ PAS. Contactez votre revendeur pour l'aide
immédiate.
E. LA PRESSION DE GAZ INSUFFISANTE GARDERA LE PILOTE DU FONCTIONNEMENT CORRECTEMENT (SI ÉQUIPÉ).
N'EMPLOYEZ PAS SI LA PRESSION DE GAZ EST INFÉRIEURE À LA CONDITION MINIMUM.
F. L'admission minimum gaz-fournissent la pression aux fins de l'ajustement d'entrée est 5" ; colonne d'eau (w.c.) sur le gaz naturel
et le 11" ; w.c. sur le gaz de propane. La pression de gaz insuffisante affectera l'opération appropriée du pilote (si équipé).
N'installez pas cet appareil à gaz si la pression minimum n'est pas disponible. L'admission maximum gaz-fournissent la pression
est 10.5" ; w.c. sur le gaz naturel et le 13" ; w.c. sur le gaz de propane. La source de propane doit être réglée. (Ne branchez
pas cet appareil directement à un réservoir de gaz propane non réglementée - cela peut provoquer une explosion.) Ne
branchez pas cet appareil à une bouteille de gaz propane portable.
G. Le système sifflant de gaz doit être classé pour fournir la pression d'admission minimum au débit maximum (BTU/hr).
La perte de pression anormale se produira si la pipe est trop petite, ou la course est trop longue. La pipe de fourniture de gaz
doit être
1
/
2
" ; diamètre intérieur minimum. Si la ligne de gaz est plus longue que 20' ; une ligne de plus grand diamètre peut
être nécessaire. Reportez-vous aux directives NFPA 54 pour plus de détails.
H. Les estimations d'entrée montrées en Btu par heure sont pour des altitudes jusqu'à 2.000 pi. Pour des altitudes au-dessus de
2.000 pi, référez-vous au code national de gaz de carburant ou entrez en contact avec le fabricant avant d'installer ce produit.
I. Cet appareil à gaz et son clapet à gaz principal doivent être disconnected du gaz-fournissent le système sifflant pendant tout
vérificateur de pression de ce système aux pressions d'essai au-dessus de 1/2 psig.
J. Cet appareil à gaz doit être isolé dans gaz-fournissent le système sifflant en fermant le robinet d'isolement d'équipement relié
au gaz-fournissent la ligne pendant tout vérificateur de pression du gaz-fournissent le système sifflant aux pressions d'essai
égales à ou moins d'à 1/2 psig.
K. Pour installer l'appareil à gaz dans votre foyer, le foyer doit satisfaire aux exigences minimales de taille (voir le tableau
des spécifications du produit dans la section SPÉCIFICATIONS).
L. Cet appareil peut être installé dans un marché des accessoires, maison (mobile) de manière permanente située et manufacturée,
où non interdit par des codes locaux. L'installation des appareils a conçu pour la maison manufacturée (États-Unis seulement)
ou installation de caravane résidentielle doit se conformer au CAN/CSA standard Z240 MH, logement mobile, au Canada, ou à
la construction et au standard de sécurité à la maison manufacturés, intitulent 24 CFR, la partie 3280, aux Etats-Unis, ou quand
une telle norme ne s'applique pas, à ANSI/NCSBCS A225.1/NFPA 501A, installations à la maison manufacturées standard.
M. NE PAS installer ce système de brûleur dans un foyer avec une lèvre en cendres ou un renfoncement supérieur à
3
/
4
".
N. Si ce système de brûleur est installé dans un foyer avec des portes en verre et que les portes ont un cadre qui obstrue le flux
d'air vers le sol du foyer, celui-ci DOIT comporter des fentes (au-dessus du sol du foyer) permettant une ventilation adéquate.
L'ouverture (avec les portes complètement ouvertes) DOIT respecter les exigences minimales de largeur et de hauteur de
la cheminée. Les portes en verre DOIVENT être complètement ouvertes lorsque le brûleur est en marche.Voir la section
SPÉCIFICATIONS pour plus de détails.
ATTENTION: L'installation et la réparation doivent être faites par un NFI certifié ou tout autre installateur professionnel qualifié.
Installateur: Lisez soigneusement ces instructions avant d'installer ce système de brûleur à gaz. Soyez sûr que vous comprenez
tous les mesures de sécurité et avertissements contenus en ce manuel.
5
IMPORTANT PRE-INSTALLATION AND FIREPLACE SAFETY INFORMATION
A. BE CAREFUL: If not installed, serviced, and used correctly per these instructions, this product can cause serious
personal injury, property damage, or loss of life.
B. WARNING: When installing in a solid-fuel-burning fireplace, the chimney flue, damper, and firebox must be thoroughly
CLEANED of soot, creosote, ashes, and loose paint, and must be inspected by a qualified chimney cleaner. Some older
fireplaces may need repair prior to installing this appliance.
C. The fireplace floor must be level and smooth.
D. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is NOT FIELD CONVERTIBLE
for use with other gasses.
CHECK GAS TYPE (natural or L.P.): The gas supply must be the same as stated on your burner system rating plate. If
gas supply is different, DO NOT INSTALL. Contact your dealer for immediate assistance.
E. INSUFFICIENT GAS PRESSURE WILL KEEP THE PILOT (IF EQUIPPED) FROM OPERATING PROPERLY.
DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT.
F. The minimum inlet gas-supply pressure for purposes of input adjustment is 5" water column (w.c.) on natural gas and
11" w.c. on L.P. gas. Insufficient gas pressure will affect proper operation of the pilot (if equipped). Do not install this gas
appliance if minimum pressure is not available. The maximum inlet gas-supply pressure is 10.5" w.c. on natural gas and
13" w.c. on L.P. gas. The L.P. source must be regulated. (Do not connect this appliance directly to an unregulated
L.P. gas tank - this can cause an explosion.) Do not connect this appliance to a portable L.P. gas cylinder.
G. The gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (BTU/hr).
Undue pressure loss will occur if the pipe is too small, or the run is too long. Gas supply pipe must be
1
/
2
" minimum
interior diameter. If the gas line is longer than 20', a larger diameter line may be necessary. Refer to the NFPA 54
guidelines for further details.
H. Input ratings shown in BTU per hour are for elevations up to 2,000 ft. For elevations above 2,000 ft., refer to the National
Fuel Gas Code or contact manufacturer before installing this product.
I. This gas appliance and its main gas valve must be disconnected from the gas-supply piping system during any pressure
testing of that system at test pressures in excess of
1
/
2
psig.
J. This gas appliance must be isolated from the gas-supply piping system by closing the equipment shutoff valve connected to
the gas-supply line during any pressure testing of the gas-supply piping system at test pressures equal to or less than
1
/
2
psig.
K. To install the gas appliance in your fireplace, the fireplace MUST meet the minimum size requirements (see
product specifications table in SPECIFICATIONS section).
L. This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not prohibited
by local codes. Installation of appliances designed for manufactured home (U.S. only) or mobile home installation must
conform with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction
and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/
NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.
M. DO NOT install this burner system in a fireplace with an ash lip or recess greater than
3
/
4
".
N. If this burner system is installed in a fireplace with glass doors, and the doors have a frame that obstructs airflow
to the fireplace floor, the frame MUST have slots (above the fireplace floor) that allow adequate ventilation. The
opening (with doors fully open) MUST meet the minimum fireplace size front width and height requirements. The
glass doors MUST be fully open when the burner is in operation. See the SPECIFICATIONS section for details.
CAUTION: Installation and repair must be done by an NFI Certified or other qualified professional installer.
Installer: Carefully read these instructions before installing this gas burner system. Be sure you understand
all safety precautions and warnings contained in this manual.
GETTING STARTED
6
INFORMATIONS SUR LA SÉCURITÉ D'EXPLOITATION DE CHEMINÉE
A. Adultes doivent être présents lors de cet appareil au gaz est en marche. Cette unité ne doit pas être laissé sans surveillance
ou brûlure lorsque tout quelqu'un dort.
B. Gardez le domaine du clair réglé de notation de gaz et libérez des matériaux combustibles, l'essence, et d'autres vapeurs et
liquides inflammables.
C. Ne pas utiliser cet appareil si une partie quelconque a été submergée. Appelez immédiatement un technicien de service qualifié
pour inspecter l'appareil et pour remplacer toute pièce du système de contrôle et toute commande de gaz qui a été sous l'eau.
Tentative d'opération peut entraîner un incendie ou une explosion entraînant des dommages matériels, des blessures ou des
pertes de vie.
D. Un écran de cheminée doit être en place lorsque le système brûle. Des dispositions pour un air de combustion adéquat
doivent être maintenues. Sauf si d'autres dispositions pour l'air de combustion sont prévues, l'écran aura une ouverture pour
l'introduction d'air de combustion. L'air de combustion est adéquat lorsque toutes les flammes sont enroulées dans le foyer et
loin de l'écran. Lorsque vous utilisez un foyer (porte) en verre, les portes en verre DOIVENT être complètement ouvertes
lorsque le brûleur est en marche.
E. Ne retirez pas les plaques signalétiques ou les étiquettes d'avertissement. Ceux-ci sont une composante de sécurité et
d'identification intégrante de cet appareil.
F. Assurez-vous de lire la section de nettoyage et l'entretien et la section de description de la flamme.
7
FIREPLACE OPERATING SAFETY INFORMATION
A. Adults shall be present when this gas appliance is operating. This unit shall not be left burning when unattended or
while anyone is sleeping.
B. Keep the area of the gas burner system clear and free from combustible materials, gasoline, and other flammable
vapors and liquids.
C. DO NOT use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system and any gas control that has been underwater. Attempted
operation may result in fire or explosion resulting in property damage, personal injury or loss of life.
D. A fireplace screen must be in place when the system is burning. Provisions for adequate combustion air must be
maintained. Unless other provisions for combustion air are provided, the screen shall have an opening(s) for introduction
of combustion air. Combustion air is adequate when all flames curl into the fireplace and away from the screen. When a
glass fireplace enclosure (door) is used, the glass doors MUST be fully open when the burner is in operation.
E. Do not remove the rating plates or the warning tags. These are an integral safety and identification component of this
appliance.
F. Be sure to read the CLEANING AND SERVICING and FLAME DESCRIPTION sections.
8
Real Fyre gas burner systems must be installed only in a solid-fuel burning fireplace with the
minimum firebox dimensions and venting requirements met (see following tables). This appliance
is designed to burn with yellow flames; adequate ventilation is absolutely necessary.
SPECIFICATIONS
Product Specifications
Specification Value Qty.
02 burner system battery type D battery 2
Remote transmitter battery type 12V battery 1
Remote receiver battery type AA battery 4
Table 2 - Technical Data (if applicable)
Model
Minimum Fireplace Size BTU Rating
Width *
Depth Height Nat. Gas L.P. Gas
Front Rear
GR47-18/20 34" 26" 17" 32" 75k 60k
GR47-24/30 40" 32" 17" 36" 95k 80k
Important Information Regarding Dimensions
* For 02 models, add 2" to both front and rear width.
These required widths allow for centering of the unit.
Rear width is at corresponding depth.
If an ash lip exists, the depth requirement begins inside of the lip (see Fig. 8-1 below).
Table 1 - Product Specifications
Fireplace
side view
Max.
3
/
4
"
ASH LIP OR
RECESS UP
TO
3
/4"
(MAX)
DEPTH to be
measured as
shown (when
ash lip exists)
Fig. 8-1 Ash lip/recess detail
Fireplace Requirements
These requirements MUST be met:
Ash Lip/Recess
DO NOT install this burner system in a fireplace with
an ash lip or recess greater than
3
/
4
". See Fig. 8-1.
9
SPECIFICATIONS (cont.)
Fireplace Requirements (cont.)
Glass Doors
If this burner system is installed in a fireplace with glass doors, and the doors have a frame that OBSTRUCTS
AIRFLOW to the fireplace floor, the frame MUST have slots (above the fireplace floor) that allow adequate
ventilation. See Fig. 9-1.
Important: The opening (with doors fully open) MUST meet the minimum fireplace size front width and height
requirements. See Table 1 (previous page) and Fig. 9-1.
Important: The glass doors MUST be fully open when the burner is in operation.
Fig. 9-1 Correct glass-doors frame setup, ventilation, and use (if applicable)
Fireplace front view
Fireplace floor
Frame
(above
fireplace
floor)
Slots that
allow
adequate
ventilation
Glass doors must
be FULLY open.
Opening (with doors
FULLY open) MUST meet
front width and height
requirements in Table 1
(on previous page)
Fig. 9-3 Incorrect glass-doors frame setup, ventilation, and use (if applicable)
INCORRECT
USE
(DO NOT operate
your burner with
glass doors only
partially open)
10
SPECIFICATIONS (cont.)
Fig. 10-2
S
02 SERIES WIRING DIAGRAM
Fig. 10-1
Valve
Ignition
module
Wire
harness
Battery
box
Ground
wire
Pilot
assembly
Electrode
wires
Manual
switch
OR
Remote
receiver
Thermo switch
17 SERIES WIRING DIAGRAM
Valve
Thermocouple
line
Pilot
assembly
Remote receiver
(optional)
Wire
harness
11
Damper clamp
Set screw
Open
Closed
DAMPER CLAMP INSTRUCTIONS
Fig. 11-1 Damper clamp detail
Fig. 11-2 Damper open / closed
The damper clamp with hex bolt (Fig. 11-1) is provided as a
means to prevent full closure of the damper blade. The clamp is
easily attached to most damper blades with pliers or a wrench,
and must be permanently installed. The clamp is designed
to prevent accidental closure of the damper when installed
as illustrated (Fig. 11-2). Should the clamp not fit, or fail to
provide the permanent vent opening listed in Table 3 below,
have a permanent stop installed, remove the damper blade,
or have the damper cut to provide the minimum permanent
opening required.
Note: The minimum chimney height from hearth to top of chimney is 15'.
Table 3 - Minimum Chimney Damper Vent Opening Requirements
Venting Requirements
THE DAMPER MUST BE COMPLETELY OPENED WHEN OPERATING THIS GAS APPLIANCE TO
ACHIEVE THE BEST VENTILATION POSSIBLE.
THESE ARE MINIMUM DAMPER OPENING SPECIFICATIONS.
Minimum permanent free opening area of chimney damper for venting (sq. in.)
For factory-built fireplaces
Chimney height 18/20" 24/30"
15' 36 47
20' 29 41
30' 23 31
For masonry-built fireplaces
15' 46 57
20' 43 52
30' 39 47
12
GR47 BURNER PARTS LIST - MANUAL (A) SERIES
Note: Photos not to scale
Replacement parts can be ordered
from your local Real Fyre dealer.
24/30" burner model shown
Pilot
18/20" model 24/30" model
Item Description Part No. Qty. Part No. Qty.
1.
or
Pilot assembly (natural)
Pilot assembly (propane)
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
2. Control valve (natural or propane) SV-19 1 SV-19 1
3.
or
Pressure regulator (natural)
Pressure regulator (propane)
PR-3NAT
PR-2LP
1
1
PR-3NAT
PR-2LP
1
1
4. Valve heat shield HS-51 1 HS-51 1
5. Regulator heat shield HS-39 1 HS-39 1
6. Flame diverter bracket SH-1 1 SH-1 1
7. Flex connector (w/ adapter), 1/2" O.D. x 12" CK-5-SP 1 CK-5-SP 1
8. Control knob w/ extension EH-11H 1 EH-11H 1
9. Grate SD-RUM-18/20 1 SD-RUM-24/30 1
10.
or
Sand (natural gas)
Vermiculite (propane gas)
CS-8
LF-15-3.5
1
1
CS-10
LF-15-7
1
1
11. Black embers EB-1 1 EB-1 1
12.
Hardware kit (damper clamp,
stabilizer clips w/ screws and nuts)
HK-1 1 HK-1 1
13. Damper clamp (only) DC-1 1 DC-1 1
Thermocouple
1
The log set is purchased and packaged separately;
contact your local Real Fyre dealer when ordering. Refer
to the instructions included with the log set.
7
10
11
9
13
12
2
3
4
5
6
8
13
GR47 BURNER PARTS LIST - 02 SERIES
Note: Photos not to scale
Replacement parts can be ordered
from your local Real Fyre dealer.
24/30" burner model shown
Pilot
18/20" model 24/30" model
Item Description Part No. Qty. Part No. Qty.
1.
or
Pilot assembly (natural)
Pilot assembly (propane)
PAC-6
PAC-7
1
1
PAC-6
PAC-7
1
1
2.
or
Control valve (natural)
Control valve (propane)
SV-45
SV-45P
1
1
SV-45
SV-45P
1
1
3. Control module IMP-1 1 IMP-1 1
4. Main harness assembly WH-11 1 WH-11 1
5.
or
Remote receiver box
(includes remote receiver, battery box, thermo switch, metal heat shield)
Switch box assembly *
(includes battery box, ON/OFF switch, thermo switch, metal heat shield)
AR-02-1
EPK-64
1
1
AR-02-1
EPK-64
1
1
6. Remote transmitter (only - if equipped) AT-R1-1 1 AT-R1-1 1
7. Valve heat shield HS-38 1 HS-38 1
8. Decorative heat shield HS-52 1 HS-52 1
9. Flame diverter bracket SH-1 1 SH-1 1
10. Flex connector (w/ adapter), 1/2" O.D. x 12" CK-5-SP 1 CK-5-SP 1
11. Grate SD-RUM-18/20 1 SD-RUM-24/30 1
12. Wire guard WHG-1 1 WHG-2 1
13.
or
Sand (natural gas)
Vermiculite (propane gas)
CS-8
LF-15-3.5
1
1
CS-10
LF-15-7
1
14. Black embers EB-1 1 EB-1 1
15.
Hardware kit (damper clamp,
stabilizer clips w/ screws and nuts)
HK-1 1 HK-1 1
16. Damper clamp (only) DC-1 1 DC-1 1
* to add a remote system to an 02M model, use RR-1A
1
The log set is purchased and packaged separately;
contact your local Real Fyre dealer when ordering. Refer
to the instructions included with the log set.
10
14
11
9
7
Heat sensor
4
8
Electrode
13
Remote transmitter and system
batteries included with burner
system (as applicable).
2
3
5
6
OR
12
15
Important: Minimum fireplace size for 02 series is larger than other GR47 models (by 2" front & rear width).
16
14
GR47 BURNER PARTS LIST - 17 SERIES
4
5
Note: Photos not to scale
Replacement parts can be ordered
from your local Real Fyre dealer.
24/30" burner model shown
2
18/20" model 24/30" model
Item Description Part No. Qty. Part No. Qty.
1.
or
Pilot assembly (natural)
Pilot assembly (propane)
PAC-1NAT
PAC-1LP
1
1
PAC-1NAT
PAC-1LP
1
1
2. Control valve (natural or propane) SV-37 1 SV-37 1
3.
Pressure regulator (natural)
Pressure regulator (propane)
PR-3NAT
PR-2LP
1
1
PR-3NAT
PR-2LP
1
1
4.
Remote kit *
(includes receiver, transmitter, batteries, plastic cover)
VR-1A 1 VR-1A 1
5. Remote transmitter (only) * AT-V1-1 1 AT-V1-1 1
6. Valve heat shield HS-51 1 HS-51 1
7. Regulator heat shield HS-39 1 HS-39 1
8.
Decorative heat shield *
HS-53 1 HS-53 1
9. Remote receiver wire harness *
WH-01 1 WH-01 1
10. Flame diverter bracket SH-1 1 SH-1 1
11. Flex connector (w/ adapter), 1/2" O.D. x 12" CK-5-SP 1 CK-5-SP 1
12. Control knob w/ extension EH-11H 1 EH-11H 1
13. Grate SD-RUM-18/20 1 SD-RUM-24/30 1
14. Wire guard WHG-1 1 WHG-2 1
15.
or
Sand (natural gas)
Vermiculite (propane gas)
CS-8
LF-15-3.5
1
1
CS-10
LF-15-7
1
1
16. Black embers EB-1 1 EB-1 1
17.
Hardware kit (damper clamp,
stabilizer clips w/ screws and nuts)
HK-1 1 HK-1 1
18. Damper clamp (only) DC-1 1 DC-1 1
* if equipped
† to add a remote system to a 17M model, use VR-1A, HS-53, and WH-01
3
The log set is purchased and packaged separately;
contact your local Real Fyre dealer when ordering. Refer
to the instructions included with the log set.
11
16
13
10
8
7
6
15
1
Pilot
Thermocouple
12
9
14
18
17
15
REFER TO THE PARTS LIST WHEN FOLLOWING
INSTALLATION INSTRUCTIONS. 24/30" burner model
shown here.
INSTALL BURNER
1. MAKE SURE FIREPLACE GAS SUPPLY IS TURNED
OFF.
2. Locate the gas-supply stub inside the fireplace and
remove the cap, if attached (reference Fig. 15-1).
CAUTION: When removing the cap, make sure the stub
does not turn, loosening the connection
inside the wall.
3. Attach the nut end of the flex connector to the adapter
found on the valve or, if attached, on the regulator
behind the valve. Tighten securely.
4. Place the burner system in the fireplace. Center the
burner from left to right in the fireplace. See Fig. 15-2.
5. Be sure gas to the fireplace is off. Remove the
adapter connected to the flex connector. Attach the
adapter to the gas-supply stub using a pipe compound
resistant to all gasses. Tighten securely. Then attach
the open end of the flex connector to the adapter.
Tighten securely (see Fig. 15-1). Ensure the pan rests
level on the fireplace floor after connection. Adjust the
pan if necessary.
6. LEAK TEST: Make sure the burner valve is in the
OFF position. Turn on the fireplace gas supply, and
test at all connections for leaks using the appropriate
soapy water solution. See Fig. 15-3. If bubbles appear,
a leak is present. Turn off the gas and tighten at all
connections. Repeat until no leaks are present. If a
leak persists, turn off the gas supply and contact the
local gas company or dealer. NEVER USE A FLAME
TO CHECK FOR LEAKS.
For manual and 17M models, continue to PREPARE
GRATE section.
INSTALL BATTERIES (if applicable)
At this stage the burner system and remote batteries are
to be installed. Reference the INSTALLING/REPLACING
BATTERIES section for details.
The Real Fyre burner system must be installed by a qualified professional service technician. Instructions
must be followed carefully to ensure proper performance and full benefit from the burner system. Check to be
sure the burner system is designed and labeled for the type of gas (natural or propane gas) supplied to
fireplace. Fireplace floor must be level, clean, and smooth (see FIREPLACE SAFETY INFORMATION section).
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury.
INSTALLATION
Fig. 15-2 Center burner pan in fireplace
Fig. 15-1 Connect gas supply
Flex
connector
Adapter
Gas
supply
stub
(17 model
shown)
Installation continued on next page
Fig. 15-3 Perform leak test
Make sure
valve is in OFF
position.
(17 model shown)
INSTALLATION
16
INSTALLATION (cont.)
Fig. 16-2 Place wire guard (if applicable)
Installation continued on next page
Fig. 16-1 Install remote receiver / switch box
and heat shield (if applicable)
Refer to separate remote instructions (if applicable)
RECEIVER ON ITS SIDE
(w/ plastic cover and heat shield)
(Burner)
Place wire guard over wire harness
Fig. 16-3 Wire guard placement detail
Wire guard
Wire harness
17 REMOTE RECEIVER PLACEMENT:
IN FIREBOX, ON LEFT SIDE
(PLACE ONLY AS SHOWN)
4"
min.
Wire harness
Bottom
(against
wall)
INSTALL REMOTE RECEIVER / SWITCH BOX
(if applicable - 02 & 17 models)
For 02 models proceed to step 2
1. 17 Models Only: If this unit was shipped with a remote,
read and follow the separate remote instructions
(packed with remote) for connecting the remote to
the valve. Then continue to step 2.
2. Place the receiver/switch box inside the firebox.
Position so that it is:
located at the left front of the firebox.
on its side, with its bottom toward the left firebox
wall.
a minimum of 4" from the burner/flame.
See Fig. 16-1, A or B for details.
DO NOT place the receiver/switch box at the rear
of the firebox. Ensure that the box wire harness
remains away from the burner, valve, heat shield,
and flame at all times. Coil any excess wire within
the box.
CAUTION: THE BOX WILL BE HOT DURING AND
AFTER OPERATION.
3. Decorative Heat Shield
Note: The decorative heatshield has a rear wall with
a notch in it. Face this notched end toward
the back of the fireplace, and route the wire
harness through the notch.
17 Models: Ensure the remote receiver is properly
installed (with the plastic cover over it). Then place
the decorative heat shield over the remote receiver.
See Fig. 16-1, A.
02 Models: Place the decorative heat shield over
the remote receiver / switch box (see Fig. 16-1, B).
CAUTION: THE REMOTE RECEIVER / SWITCH
BOX AND DECORATIVE HEAT SHIELD
WILL BE HOT DURING AND AFTER
OPERATION.
PLACE WIRE GUARD (if applicable)
1. 02, 02M, & 17 models only: Place the wire guard
over the wire harness that is routed along the rear
of the fireplace. (The wire routes from the valve
assembly to the remote receiver / switch box.) See
Fig. 16-2 and 16-3.
Note: Manual models and 17M models without a
remote system do not require this step. Proceed
to the next section.
A
B
- OR -
RECEIVER/BOX ON ITS SIDE
(w/ heat shield)
02 RECEIVER/BOX PLACEMENT:
IN FIREBOX, ON LEFT SIDE
(PLACE ONLY AS SHOWN)
4"
min.
Wire harness
Bottom
(against
wall)
17
INSTALLATION (cont.)
Fig. 17-1 Attach stabilizer clips to grate
Fig. 17-2 Position grate
(24/30" grate shown)
Fig. 17-3 Grate placement detail
Installation continued on next page
PREPARE GRATE AND CENTER
1. Locate the grate (outside of the fireplace), and attach
the stabilizer clips to the 2 inner bars of the grate
using the provided screws and nuts (see Fig. 17-1
and Fig. 17-3).
The stabilizer clips should be positioned on the inner
bars and oriented as shown. Note the 1
1
/
2
" spacing
in Fig. 17-3. Tighten the clips in place.
2. Position the grate over the burner pan (in the fireplace)
so that:
the stabilizer clips fit over the back edge of the
pan to lock it in position.
the rear grate legs insert into the wire guard
cutouts (if applicable).
the assembly is centered from left to right.
See Fig. 17-2 and Fig. 17-3.
Then remove the grate for future media placement.
(Remove grate after centering burner)
Clips fit over back edge of pan
Grate legs insert into wire guard cutouts
(if applicable)
(Top View)
(Side View)
Legs insert into
wire guard
(if applicable)
Spacing: 1
1
/
2
"
Clips fit
over burner
Attach here
18
HEAT SHIELD PLACEMENT
TO PREVENT DAMAGE AND FAILURE:
IT IS CRITICAL THAT THE HEAT SHIELD(S) BE PLACED
CORRECTLY OVER THE REGULATOR AND/OR VALVE
PRIOR TO OPERATION.
TO PREVENT OVERHEATING:
Place the valve heat shield over the valve as shown in the
applicable image of Fig. 18-1. It should rest flat above the valve.
For manual and 17 models, place the regulator heat shield
as shown in the applicable image of Fig. 18-1. It should rest
flat above the regulator.
Keep the area above and below the heat shield(s) clear
of decorative media or any other objects at all times.
DO NOT remove the heat shield(s).
Important: Ensure any lines/tubes/wires from the valve
do not interfere with heat shield placement.
LIGHTING TEST
Prior to proceeding with installation, perform a lighting test
(see lighting instructions for lighting your burner). Allow the
unit to completely cool after testing.
LAVA GRANULES/COALS (optional)
Optional lava granules and lava coals are available for
decorative purposes. Contact your dealer for ordering
information.
If purchased, follow the steps below.
1. Spread the lava granules on the floor of the fireplace,
around the front and sides of the burner system (see
Fig. 18-2).
2. Repeat this process for the lava coals (on top of the
already placed lava granules).
Note: DO NOT place any lava media on the burner
system, behind it, on or within the heat shield, or
under a knob if one exists at the front of the valve
(see Fig. 18-3).
For models with a receiver/switch box, the lava media
may be placed around the box. Leave the front of the
receiver/switch box clear for control access.
INSTALLATION (cont.)
IMPORTANT
For all valves, the air MUST be purged from the gas line
before the pilot will light and burn properly. The time needed
to purge will depend on the length of the gas line to the
unit and the amount of time since the unit or gas line was
last used. It may take several minutes before all the air is
purged and the pilot will light and burn properly. Reference
the LIGHTING INSTRUCTIONS section in this manual.
Installation continued on next page
Fig. 18-2 Place lava media (if purchased)
Fig. 18-3 Proper lava media placement
Keep clear
(17 model shown)
Fig. 18-1 Place heat shield(s)
Heat shield(s) MUST:
be placed over regulator and/or valve
(DO NOT remove)
rest flat
be kept clear of all media and objects
Manual and 17 Models
02 Model
2 heat
shields
19
SAND/VERMICULITE PLACEMENT
The sand/vermiculite supplied with the unit is specially
selected for use with either natural or propane gas. It
maximizes flame distribution and provides a cleaner
burning flame.
CAUTION: Use only sand for natural gas burners and
vermiculite for propane gas burners.
1. Fill the burner pan completely with the sand/
vermiculite (see Fig. 19-1). Avoid spilling the sand/
vermiculite on the pilot assembly. DO NOT place
sand/vermiculite on any other parts of the burner,
valve, or heat shield.
2. Slope the sand/vermiculite at the same angle as
the burner pan. This is important to ensure quiet
lighting and even flame distribution. See Fig. 19-2.
BLACK EMBERS PLACEMENT
Spread the black embers lightly and evenly over the entire
surface of the sand/vermiculite as shown in Fig. 19-3.
Break up any clumps that may have developed during
shipment. Completely cover the sand/vermiculite. DO
NOT pack the embers down.
KEEP LAVA GRANULES/COALS, SAND/
VERMICULITE, EMBERS, AND ALL FOREIGN
OBJECTS AWAY FROM THE PILOT ASSEMBLY,
VALVE ASSEMBLY, AND HEAT SHIELD(S)
DURING MEDIA PLACEMENT AND AT ALL TIMES.
SEE FIG. 19-4.
INSTALLATION (cont.)
Installation continued on next page
Fig. 19-3 Place black embers
Fig. 19-4 Keep pilot, valve, & shield(s) clear
Place embers as shown
Fig. 19-1 Place sand/vermiculite
Fig. 19-2 Sand/vermiculite detail
Fill pan (only) with
sand / vermiculite
& slope with pan.
(17 model shown)
KEEP CLEAR
OF ALL MEDIA
20
GRATE PLACEMENT
1. Place the grate over the burner pan so that:
the stabilizer clips fit over the back edge of the
pan to lock it in position.
the rear grate legs insert into the wire guard
cutouts (if applicable).
See Fig. 20-1.
2. Place a second layer of embers lightly and evenly
over the burner and grate area. Be sure to cover the
grate bars/fingers as shown. See Fig. 20-1.
Break up any clumps that may have developed during
shipment. Completely cover the area as shown. DO
NOT pack the embers down.
Store unused embers for later use/replacement.
INSTALLATION (cont.)
Fig. 20-1 Place grate
Installation continued on next page
Fig. 20-2 Place additional black embers
Cover entire area with second layer of embers
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Real Fyre GR47 Le manuel du propriétaire

Catégorie
Cheminées
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues