Honeywell MN4CFS9 Manuel utilisateur

Catégorie
Humidificateurs
Taper
Manuel utilisateur
Portable Air Conditioner
User Manual
Read and save these instructions before use
EN
Climatiseur portatif
Mode d’emploi
Lire ces consignes avant l’utilisation de l’appareil et les conserver
FR
Aire Acondicionado Portátil
Manual del Propietario
Lea y guarde estas instrucciones antes de usar la unidad
ES
Model / Modèle / Modelo:
MN4CFS9/ MN4HFS9/
MN4CFSBB9/ MN4HFSBB9/
MN4CFSWW9/
MN4HFSWW9
Customer Support:
Assistance Au Client:
Servicio de atencion a clientes:
Web: www.HoneywellAirComfort.com
USA: 1-800-474-2147 | [email protected]
^ Canada Customer Support service available for models sold in Canada only.
^ Le Service Client Canadien est disponible uniquement pour les modèles vendus sur le territoire Canadien.
^ Servicio de Atención A Clientes en Canadá disponible solo para modelos vendidos en Canadá.
Check the website for FAQs, usage guides, and more !
Consultez le site Web pour les FAQ, les guides
d'utilisation et plus encore !
Consulte el sitio web para ver las preguntas frecuentes,
las guías de uso y mucho más.
www.HoneywellAirComfort.com
Contact UsProduct Registration
EN
SAFETY
DO NOT operate the unit with a damaged plug or loose wall
outlet. If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent, or similarly qualified persons in
order to avoid a hazard.
DO NOT cover the air intake and exhaust when in use.
DO NOT place objects on or sit on the unit.
Always turn off and unplug the unit when cleaning or servicing.
DO NOT use the appliance if it is damaged.
If service is needed, contact an authorized service agent.
Unplug the unit when stored or not in use.
DO NOT pull or carry the appliance by the power cord.
DO NOT pinch the power cord in the door and DO NOT pull it
along edges or sharp corners.
DO NOT run the power cord under carpeting or rugs.
Use caution to prevent tripping on cord.
DO NOT use the device in the following cases:
- Near a fire source
- In areas where gasoline, paint, or other flammable
goods are stored
- In an area where water is likely to be sprayed or projected.
DO NOT touch the plug or the device with wet hands.
Basic safety precautions should always be followed when using
electrical appliances.
This appliance has been manufactured for use in domestic
environments and should not be used for other purposes.
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS. READ CAREFULLY AND
KEEP FOR FUTURE REFERENCE. IN CASE THERE IS ANY
INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH
VERSION AND ANY OTHER LANGUAGE VERSION OF THE
CONTENT OF THIS MATERIAL, THE ENGLISH VERSION SHALL
PREVAIL.
WARNING:
EN
SAFETY (CONTINUED)
Only use the installation kit provided to install this unit.
DO NOT attempt to extend the hose or install this unit using
other methods other than those shown in this manual.
Improper installation will void any existing warranties.
DO NOT use an extension cord with this unit.
This appliance can be used by children aged 8 years and
above and persons with reduced physical, sensory, or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
Never insert your fingers or rods into the air outlet. Take special
care to warn children of these dangers.
The manufacturer is not liable for injury caused to persons or
property damage due to non-compliance with maintenance
instructions and improper use of the appliance.
The appliance shall be installed in accordance with national
wiring regulations.
The appliance is not to be used by persons (including children)
with reduced physical, sensory, or mental capabilities, or lack
of experience and knowledge, unless they have been given
supervision or instruction.
Children should be supervised to ensure that they do not play
with the appliance.
Electrical equipment and installations regulated by national
legislation must be followed.
The appliance should be transported upright.
DO NOT turn on the appliance for at least one hour before first
use.
It is essential that the appliance is connected to an efficient
ground connection checked by a qualified electrician.
EN
SAFETY (CONTINUED)
Possible leaks of refrigerant gas in unventilated rooms could
lead to fire or an explosion hazard should the refrigerant come in
contact with electric heaters, stoves, or other sources of ignition.
Use care when storing the appliance to prevent damage that
could cause mechanical faults.
Only persons authorized by an accredited agency certifying their
competence to handle refrigerants in compliance with sector
legislation should work on refrigerant circuits.
DO NOT use means to accelerate the defrosting process or to clean
the unit other than those recommended by the manufacturer.
Flammable substances or pressurized containers (e.g. aerosol
cans) should be kept a minimum of 50cm away from heat or fire.
Use only implements recommended by the manufacturer for
defrosting or cleaning.
DO NOT operate your air conditioner in a wet room such as a
bathroom or laundry room.
The machine works optimally when the humidity is within the
range 3080% RH.
This appliance should be used in a room that allows for good
ventilation between the unit and any walls/furniture or other
objects. The room size should correspond to the room area as
specified for operation by the manufacturer and the appliance
should be well kept to prevent mechanical damage.
Keep ventilation openings clear of obstructions.
Do not pierce or burn the refrigerants.
Be aware that refrigerants may not contain an odor.
Do not modify this appliance in any way so as to avoid danger.
All working procedures that affect safety shall only be carried out
by competent persons.
EN
R32 SAFETY
SYMBOL NOTE EXPLANATION
WARNING
This symbol shows that this
appliance uses a flammable
refrigerant. If the refrigerant
is leaked and exposed to
an external ignition source,
there is a risk of fire.
CAUTION
This symbol shows that the
operation manual should be
read carefully.
CAUTION
This symbol shows that a
service personnel should be
handling this equipment with
reference to the installation
manual.
CAUTION
This symbol shows that
information is available, such
as the operating manual or
installation manual.
R32
A2L
EN
R32 SAFETY
Read the instructions carefully before using the appliance.
R32 refrigerant gas complies with UL60335240 / UL603351.
This appliance contains a certain number of grams (see
rating label at the back of the unit) of R32 refrigerant gas. The
maximum refrigerant charge amount is not greater than R32
1.84 kg based on UL60335240.
When defrosting or cleaning, do not use any method other than
those recommended by the manufacturer.
Do not place the appliance in a room with continuous sources
of ignition (e.g. open flame, operating gas appliance, or working
electrical heater).
Do not pierce and do not burn.
Do not perforate any part of the refrigerant circuit.
Refrigerant gas may be odorless.
The appliance must be installed, used, and stored in an area that
is greater than R32 gas: 4 m².
Accumulation of possible refrigerant leaks in an unventilated
room could lead to fire or explosion should the refrigerant come in
contact with electric heaters, stoves, or other sources of ignition.
The appliance must be stored in a way to prevent mechanical
damage and in a well-vented area.
Only individuals authorized by an accredited organization
certifying their competence to handle refrigerants in compliance
with industry legislation should work on the refrigerant circuit.
Servicing shall be performed only as recommended by the
manufacturer.
All working procedures that affect safety means shall only be
carried by competent persons.
Additional warnings for appliances with R32 refrigerant gas.
EN
R32 SAFETY
Repair must be performed based on the recommendations from the manufacturer.
Maintenance and repair that requires the assistance of other qualified personnel must be
performed under the supervision of specialists in the use of flammable refrigerants.
CAUTION
Risk of Fire or Explosion due to Flammable Refrigerant Used.
Follow Handling Instructions Carefully in Compliance with National Regulations.
This marking indicates that this product should not be disposed with other household
waste throughout the US. To prevent possible harm to the environment or human
health from uncontrolled waste disposal, recycle it responsibly to promote the
sustainable reuse of material resources. To return your used device, please use return
and collection systems or contact the retailer where the product was purchased. They
can take this product for environmentally safe recycling.
Transport of equipment containing flammable refrigerants must
comply with local transport regulations.
Marketing of equipment using signs must comply with local
regulations.
Disposal of equipment using flammable refrigerants must
comply with national regulations.
The storage of equipment should be in accordance with the
manufacturers instructions.
Storage package protection should be constructed such that
mechanical damage to the equipment inside the package will
not cause a leak of the refrigerant charge.
The maximum number of pieces of equipment permitted to be
stored together will be determined by local regulations.
Transportation, marking, and storage for units.
1.
2.
3.
4.
5.
1
THANK YOU
USER TIPS
Congratulations on your purchase of this Honeywell Portable Air Conditioner.
Regarding the information pertaining to the installation, handling, servicing, cleaning, and disposal
of the appliance, please refer to the below section of the manual.
Portable Air Conditioners are ideal for spot cooling. The compressor, condenser, and evaporator are
housed in a compact unit. The air is dehumidified and cooled while a flexible Exhaust Hose sends
heat outside. The air conditioner includes a window venting kit. No permanent installation is needed.
The unit is easy to move from room to room and offers a truly flexible air conditioning solution.
Auto Evaporation System - The unit automatically evaporates the condensate through the Exhaust
Hose. There is no need to empty the drainage tank except in humid conditions. Read and follow the
instructions carefully.
To ensure optimal efficiency of the product, keep doors and windows closed when it is used as an air
conditioner or dehumidifier. If the product is being used with the Fan Function only, an open window
could improve air circulation.
EN
Important:
Before installing the unit, place it UPRIGHT for 1 hour before use to allow the refrigerant to stabilize.
Manually adjust the air vent located at the top of the unit to adjust the direction of air flow.
Follow installation instructions to set up the unit.
Plug the unit into a properly grounded circuit. DO NOT plug into an extension cord.
Cooling, Heating* and Dehumidifying
Operation Fan Operation
*Applicable for models with Heating feature only.
2
PARTS DESCRIPTION
EN
1) Air Outlet 7) Power Supply Cord
2) Control Panel
(Incl. Signal Receptor)
8) Upper Grill and Dust Filter
3) Casters 9) Upper Drain Plug
(Dehumidifier Mode)
4) Handle 10) Lower Grill and Dust Filter
5) Air Exhaust Outlet 11) Lower Drain Plug with Plastic Cap
(Air Conditioning Mode)
6) Remote Control
10
9
11
7
8
6
1
4
5
2
3
3EN
INSTALLATION
It is important that the installation instructions below are followed for successful installation of this
Portable Air Conditioner. Please call Customer Support if you have any difficulties or queries
regarding these installation procedures.
Installation Kit:
1. Window Bracket Kit (1 Set) 5. Exhaust Hose (1 Piece)
2. Window Bracket Panel Adapter (1 Piece) 6. Insulation Tape (gray,
adhesive)
(1 Piece)
3. Exhaust Hose Connector (1 Piece) 7. Insulation Tape (black,
adhesive)
(1 Piece)
4. Hole Cover (1 Piece) 8. Foam Insulation Pads
(non-adhesive)
(2 Pieces)
1 3
x1 x1x1
2
4
x1
5
x1
6
x1 x1
7 8
x2
4
Installation Steps:
Remove the pre-assembled Exhaust Hose Connector, Exhaust Hose, and Window Bracket Panel
Adapter from the package.
1.
INSTALLATION (CONTINUED)
2. The Window Brackets are approximately 19.7" (50 cm) each, allowing you in install to windows
and balcony doors of different heights or widths.
Adjustable Knobs
EN
19.7" (50 cm)
1 part
19.7" (50 cm) to
38.2" (97 cm)
2 parts
47.2" (1.2 m)
3 parts
Hose:
Length: 12" to 47" (30 cm to 120 cm)
Note: After setting the window bracket to the size of your window, please remove it from the window
and follow the instructions below.
To install the window bracket to the window frame, you need to adjust the height or width of the
window bracket by extending the length according to the height or width of the window. When the
length is set, tighten the Adjustable Knobs (preinstalled on the window bracket) to ensure the window
bracket is secured in the desired position. Use one or all three pieces of window bracket as needed.
5
3. Connect the Exhaust Hose to the rear exhaust outlet on the back of the unit. Slide in the Hose
Connector from up to down. Make sure all sides are secured within the outlet slots.
EN
INSTALLATION (CONTINUED)
4. Connect the window bracket to the window bracket panel adapter by sliding the panel adapter
into the hole of the window bracket, then rotate clockwise until it is locked in place.
6EN
INSTALLATION (CONTINUED)
Measure and cut the Insulation Tape (adhesive) to the full length of your window sash and frame.
Peel off the adhesive backing and slowly attach them to the window sash and frame. The gray
tape should attach to the movable window sash.
5.
Horizontal Sliding Window Vertical Sliding Window
Gray Window Sash
Window Sash
Window Frame Gray
Black Black
6. Connect the window bracket to the window.
7EN
INSTALLATION (CONTINUED)
8. The air conditioner is now ready to use.
7. Position the non-adhesive Foam Insulation Pads on both edges that are not covered by the
adhesive Insulation Tape to seal gaps and prevent air and insects from entering the room.
Horizontal Sliding Window Vertical Sliding Window
Foam
Insulation Tape
(adhesive)
Foam
Insulation Pad
(non-adhesive)
Foam
Insulation Pad
(non-adhesive)
Foam Insulation
Tape (adhesive)
8
INSTALLATION (CONTINUED)
IMPORTANT: Do not change or lengthen the Exhaust Hose as this could cause the unit to
malfunction.
The supplied Exhaust Hose has a diameter of 5.91” (15cm) and can be extended from
12" to 47" (30 cm to 120 cm).
Do not bend (to the extent shown above) the Exhaust Hose. A bent hose will block exhaust air and
cause the unit to malfunction or shut off.
Make sure the back of the unit is at least 31.5" (80 cm) away from the wall and the minimum air
space from top/front/left/right is 20" (50cm). Do not place the unit in front of curtains or drapes
as this could obstruct the airflow.
WARNING: Any warranties included with this product will be voided if an extra extension hose is
added to the originally provided installation kit or if the installation is performed differently than the
manufacturer's instructions, without proper consultation. Please contact Customer Support for help
with installation procedures if needed.
NOT RECOMMENDED
THE MINIMUM AIR SPACE
RECOMMENDED
31.5" (80 cm)
20" (50 cm)
20"
(50 cm)
20"
(50 cm)
MAX. 14" (36 cm)
EN
MAX. 40" (102 cm)
MIN 35.6 cm
9
USE & OPERATION
EN
CONTROL PANEL
FUNCTION BUTTONS
The Power Control turns the unit on and off. When the unit is plugged in, this button lights up indicating it
is in Standby Mode ready to be switched on anytime.
POWER CONTROL
1) Power Control / Standby Mode 4) Timer/Temperature Set Controls
2) Warning Light (when flashing) 5) Fan Speed Control
3) Mode Control 6) Timer Control
Settings: Air Conditioning, Heating*, Dehumidifying, Fan.
The corresponding indicator light will illuminate to indicate the current mode setting.
MODE CONTROL
Air Conditioning Mode
Adjust fan speed and air temperature to suit your desired comfort level.
Temperature setting range is 16°C - 32°C (61°F - 89°F).
Usage humidity range is 30%80% RH.
(6) (5) (4) (4) (3) (1),(2)
Condensation may accumulate in the unit.
If the internal tank becomes full, the Power Control light will flash and the unit will not operate until
the unit has been drained (refer to Water Condensate Drainage).
After switching the air conditioner off, you must wait 3 minutes before switching it back on again.
WARNING LIGHT
*Applicable for models with Heating feature only.
10
USE & OPERATION (CONTINUED)
EN
Heating Mode*
This unit uses HeatPump technology which reverses the air conditioning cooling cycle by
transferring heat from the outside into the room – this is more energy efficient than traditional
electric heaters that generate heat instead of transferring heat into the room. These properties
make this heater ideal for use in autumn or spring when outdoor temperatures are not severely
cold, or as supplemental heating in colder rooms of your home.
Fan Mode
For air circulation without air conditioner cooling.
Dehumidifying Mode
Air is dehumidified as it passes through the unit without being in full cooling mode.
If room temperature is higher than 25°C (77°F), fan speed can be adjusted. Otherwise, fan speed
is preset to LOW.
Note: If the unit will be used mainly as a dehumidifier, do not connect the Exhaust Hoses.
Continuous drainage is then necessary (refer to Continuous Draining for Dehumidifier Mode).
When heating mode is selected, the indicator light will shine. Heating is activated only when
the ambient temperature is below 25°C (77°F). In this mode, the desired temperature can be
set between 16°C 25°C (61°F - 77°F).
Note: The Exhaust Hoses must vent outside the room when using heating mode.
IMPORTANT: The Heat pump draws moisture from the air which then condenses into the
internal water tank. The unit will pause operation when the tank is full and will restart when
the tank has been emptied. It is recommended to use the heating mode in a room with 50%
humidity or lower. Avoid operating moisture-producing products or appliances such as a
humidifier or a kettle when using the unit in heating mode.
See the "Draining Water Condensate in Heat Mode" section for more information on draining
the water tank.
FUNCTION BUTTONS (CONTINUED)
IMPORTANT: The Dehumidifier mode is used to support moisture reduction but should not be
expected to dehumidify to the same degree as a standard dehumidifier-only appliance. The
built-in dehumidifier automatically adjusts dehumidification based on ambient room temperatures.
It is not possible to adjust to a desired humidity percentage. The front display only shows the
current AND desired temperatures. It does not show humidity levels.
*Applicable for models with Heating feature only.
11
EN
FUNCTION BUTTONS (CONTINUED)
While the unit is turned on, press the timer button, then press the or to select the number of
hours you would like the unit to continue to run. The unit will turn off automatically.
AUTO TURN OFF:
While unit is running, press the or button to select the number of hours you want the unit to run
in air conditioning mode.
AUTO TURN ON:
When unit is in standby mode (plugged in with power light on), press the or button to select the
number of hours until you want the unit to automatically start running.
TIMER CONTROL
TEMPERATURE / TIMER SET CONTROLS
Used for adjusting the timer and thermostat.
The default display is the set temperature.
In cooling mode, when or button is pressed, the set temperature is displayed and may be
adjusted. After 10 seconds, the display will revert back to room temperature. Temperature is only
adjustable in cooling mode. The time is adjustable between 1 - 24 hours.
Note: By pressing both or buttons at the same time, the display will toggle between
Celsius(°C) and Fahrenheit(°F).
3 settings: High, Medium, and Low.
FAN SPEED CONTROL
USE AND OPERATION (CONTINUED)
12EN
USE & OPERATION (CONTINUED)
REMOTE CONTROL
The functions work the same as the Portable Air Conditioner's Control Panel.
All key functions can be accessed from the remote control.
Note:
Battery Installation: Remove the cover on the back of the remote control and insert two AAA
batteries with + and - pointing in the proper direction according to the polarity markings.
Use only two AAA or IEC R03 1.5V batteries.
Remove the batteries if the remote control is not in use for a month or longer.
All batteries should be replaced at the same time. Do not mix with old batteries.
Do not mix alkaline, standard (carbon-zinc), or rechargeable (nickel-cadmium) batteries.
Properly dispose of used batteries.
Caution:
Power Control
ON/OFF
Temperature/Timer Set
Used for adjusting the timer and
temperature.
When the or key is pressed, the
set temperature is displayed and
may be adjusted
Timer setting is available from 1 - 24 hours
by pressing the key or .
Fan Speed Control
Timer Control
In running mode: Auto switch off
In standby mode: Auto switch on
Press or button to adjust the
time setting by 1 hour intervals.
HIGH/MID/ LOW
Mode Control
Air Conditioning Dehumidifying
Heating* Fan
Press this button to change the operation
mode in the order of:
*Applicable for models with Heating feature only.
This device complies with part 15 of the FCC Rules. Operation is subject to following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment dose cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/ TV technician for help.
Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority
to operate the equipment.
13
CLEANING & MAINTENANCE
EN
Appliance Maintenance:
Turn off the appliance before disconnecting the power supply.
Only clean the appliance with a soft, dry cloth.
1.
2.
WARNING: DO NOT power or operate the Air Conditioner when cleaning or when any or both of the
Rear Grills are removed from the unit, or if there is a loose-fitting Rear Grill(s). DO NOT attempt to
handle or touch any of the parts or wiring inside the air conditioner after the Rear Grill(s) are removed
from the unit. Doing so can cause serious injury or electrical shock.
Switch off and unplug the air conditioner from
the electrical outlet.
Remove the Upper Dust Filter and the Lower Dust Filter.
Gently wash using water and/or diluted liquid dishwashing
detergent.
Rinse thoroughly and gently shake excess water from
the filters. Make sure the filters are dry before reinstalling.
Note: You may use a vacuum cleaner to remove dust.
Replace the Upper Dust Filter and the Lower Dust Filter
onto the unit.
1.
2.
3.
4.
Dust Filter Maintenance:
The dust filter is to be cleaned every two weeks to maintain
air cooling efficiency. Please follow the below instructions to
clean the dust filter:
Rear Grill
Lower
Dust Filter
Upper
Dust Filter
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80

Honeywell MN4CFS9 Manuel utilisateur

Catégorie
Humidificateurs
Taper
Manuel utilisateur

dans d''autres langues