This appliance is not intended for use by persons (including children) with reduced
physical,
sensory
or mental capabilities or lack of experience and knowledge, un-
less they have been given supervision or instruction concerning use of the appli-
ance by a person responsible for their safety.
Children should be supervised to ensure they are away from the appliance.
Do not dispose this product as unsorted municipal waste. Collection of
such waste separately for special treatment is necessary.
Content
Operation Notices
Precautions............................................................................................................1
Parts name ............................................................................................................2
Remote Screen Operation Guide
Buttons on remote controller .................................................................................3
Introduction for icons on display screen ................................................................3
Introduction for buttons on remote controller .........................................................4
Function introduction for combination buttons .......................................................7
Operation guide .....................................................................................................8
Replacement of batteries in remote controller .......................................................8
Emergency operation ............................................................................................9
Maintenance
Clean and maintenance.........................................................................................9
Trouble Shooting
Basic Trouble shooting ........................................................................................12
Installation Notice
Installation dimension diagram ............................................................................16
Tools for installation .............................................................................................17
Selection of installation location ..........................................................................17
Requirements for electric connection ..................................................................18
Installation
Installation of indoor unit......................................................................................19
Installation of outdoor unit ...................................................................................24
Vacuum pumping .................................................................................................29
Leakage detection ...............................................................................................28
Check after installation ........................................................................................30
Test and operation
Test operation ......................................................................................................30
Attachment
Pipe expanding method .......................................................................................31
1
Precautions
Warning
● Do not connect air conditioner to multi-purpose socket.Otherwise, it may
cause fire hazard
● Disconnect power supply when cleaning air conditioner. Otherwise, it may
cause electric shock.
● Do not spray water on indoor unit. It may cause electric shock or malfunction.
● Do not spill or submerge remote controller in liquids, remote may
malfunction or no longer operate.
● Do not repair air conditioner by yourself. It may cause electric shock or
damage. Please contact dealer when you need to repair air conditioner.
● Do not block air outlet or air inlet. It may cause malfunction.
If you need to relocation of air conditioner is required please contact
licensed authorize service or contact dealer for more information. Otherwise
personal injury or damage can occur.
● Do not step on top panel of outdoor unit, or put heavy objects. It may cause
damage or personal injury.
● Do not extend fingers or objects into air inlet or air outlet. It may caus
personal injury or damage.
Air Conditioner should be properly grounded. Incorrect grounding may cause
electricshock.
Do install the diconnect. If not, it may cause malfunction.
● Installation and maintenance must be performed by qualified professionals
Otherwise, it may cause personal injury or damage.
Working temperature range
Indoor side DB/WB(°F/) Outdoor side DB/WB(°F/)
Maximum cooling 89.6/73.4(32/23) 109.4/78.8(43/26)
Maximum heating 80.6/-(27/-) 75.2/64.4(24/18)
Indoor side DB/WB(°F/) Outdoor side DB/WB(°F/)
Maximum cooling 89.6/73.4(32/23) 115/78.8(46/26)
Maximum heating 80.6/-(27/-) 75.2/64.4(24/18)
The operating temperature range (outdoor temperature) for cooling only unit is
5°F(-15°C) ~ 118°F(48) ; for heat pump unit is -4°F(-20) ~ 75°F(24) .
The operating temperature range (outdoor temperature) for cooling only unit is
5°F(-15) ~ 115°F(46 ); for heat pump unit is 19°F(-7) ~ 75°F(24 ).
MM24YJ
MM18YJ
2
Parts name
Indoor Unit
Outdoor Unit
air inlet
panel
filte
horizontal louver
air outlet
heating indicator
temp. indicator
cooling indicator
power indicator
receiver window
aux.button
drying indicator
display
remote control
air inlet
handle
handle
air outlet
Notice:
Actual product may be different from above graphics, please refer to actual
products.
MODE
(AUTO/COOL/DRY/FAN/HEAT).
setting.
: Press to decrease temperature
setting.
FAN
Press it set swing angle.
TIMER ON
CLOCK
TEMP
TIMER OFF
Press
to set auto-off timer
TURBO
SLEEP
LIGHT
Press it to set auto-on timer.
Press to set clock.
1
6
7
5
3
2
4
11
10
14
9
12
13
15
Operation of Remote Controller
3
9
10
13
12
5
4
11
8
7
2
1
6
8
Press to turn on/off the light.
Press to start or stop operation.
: Press to increase temperature
Press to set fan speed.
Press to select operation mode
SENSOR
AIR SWEEP
EXTEND
AUTO
15
14
START / STOP
3
DIGITAL display:
This area will show the set tempe-
rature.
LOCK icon:
is displayed by pressing "+"
and - buttons simultaneously. Press
them again to clear the display.
LIGHT icon:
is displayed by pressing the
LIGHT button. Press LIGHT button
again to clear the display.
22
MODE icon:
If MODE button is pressed,
current operation mode icon
(AUTO), ( COOL),
(DRY), (FAN) or (HEAT
only for heat pump models) will show.
18
is displayed when pressing
display.
After pressing TIMER button, ON or
OFF will blink.This area will show
the set time.
SET TIME display:
Pressing TEMP button,
(set temperature),
ambient temperature)
(outdoor ambient temperature)
and blank is displayed circularly.
(indoor
TEMP icon:
SLEEP icon :
is displayed by pressing
the SLEEP button. Press this
button again to clear the display.
19
is displayed when pressing the
nottub siht sserP.nottub OBRUT
again to clear the display.
TURBO icon:
Operation of Remote Controller
icon:
AIR SWEEP
16
17
21
20
23
24
16
1
7
18
19
20
21
22
23
24
the
button.
AIR SWEEP
Press this button again to clear the
27
26
25
4
is displayed when pressing the
again to clear the display.
Press FAN button to select the
desired fan speed setting (AUTO-
Low-Med-High).Your selection will
be displayed in the LCD windows,
except the AUTO fan speed.
FAN SPEED display:
is displayed when pressing the
to clear the display.
Operation of Remote Controller
icon:
SENSOR
icon:
EXTEND
EXTEND
button. Press this button
26
25
27
16
1
7
18
19
20
21
22
23
24
27
26
25
5
SENSOR
button. Press this button
again
Pressing CLOCK button,
blinks. Within 5 seconds , pressing + or - button adjusts the
CLOCK :
present time. Holding down either button above 2 seconds increases or decreases the
time by 1 minute every 0.5 second and then by 10 minutes every 0.5 second. During
blinking after setting, press CLOCK button again to confirm the setting, and then
will
be constantly displayed.
7
Remote Controller Description
:
This button is used for setting Fan Speed in the sequence that goes from AUTO,
to
then back to Auto.
,
,
,
FAN
:
6
MODE :
5
Each time you press this button, a mode is selected in a sequence that goes from AUTO,
COOL,DRY, FAN,and HEAT
*
, as the following:
AUTO
COOL
DRY
FAN HEAT
*
*Note: Only for models with heating
function.
After energization, AUTO mode is defaulted. In AUTO mode, the set temperature will not
be displayed on the LCD, and the unit will automatically select the suitable operation
mode in accordance with the room temperature to make indoor room comfortable.
1
3
2
4
Press this button to turn on the unit .Press this button again to turn off the unit.
Press this button to decrease set temperature. Hold it down for 2 seconds or more
to rapidly decrease set temperature. In AUTO mode, set temperature is not
adjustable.
Press this button to increase set temperature. Hold it down for 2 seconds or more
to rapidly increase set temperature. In AUTO mode, set temperature is not
adjustable.
Auto
Low speed
Medium speed
High speed
Remote Control Instructions
SENSOR (SAVE)
:
Press this button to turn on SENSOR(SAVE) function. Saves room ambient temperature
and automatically adjusts maintaining that room ambient until pressed again which
cancels the SENSOR(SAVE) function.
START / STOP
:
AUTO
6
13
TEMP:
ambient temperature, 5s later or within 5s, it receives other remote control signal that will
return to display the setting temperature. if the users haven't set up the temperature
displaying status,that will display the setting temperature.(This function is not applicable
for some models).
TIMER ON :
TIMER OFF :
11
10
TURBO:
12
Press this button to initiate the auto-ON timer. To cancel the auto-timer program, simply
press this button again.
After pressing this button, disappears and "ON "blinks
. 0
0:00 is displayed for ON time
setting. Within 5 seconds, press + or - button to adjust the time value. Every press of either
button changes the time setting by 1 minute. Holding down either button rapidly changes the
time setting by 1 minute and then 10 minutes. Within 5 seconds after setting, press TIMER
ON button to confirm.
Press this button to set up & down swing angle, which circularly changes as below:
OFF
This remote controller is universal. If any command , or is sent out,
the unit will carry out the command as
indicates the guide louver swings as:
fan will continue operation for 10 min utes in order to dry the indoor unit even though you
have turned off the unit.
HEAT mode.
Press this button to activate / deactivate the Turbo function which enables the unit to
reach the preset temperature in the shortest time. In COOL mode, the unit will blow strong
cooling air at super high fan speed. In HEAT mode, the unit will blow strong heating air
at super high fan speed. (This function is not applicable for some models).
Press this butto
n to initiate the auto-off timer. To cancel the auto-timer program, simply
press the button again.TIMER OFF setting is the same as TIMER ON.
9
8
AIR SWEEP:
EXTEND(DRY):
Pressing button in COOL or DRY mode, the icon is displayed and the indoor
After energization,
OFF is defaulted. is not available in AUTO, FAN or
EXTEND
EXTEND
EXTEND
Remote Control Instructions
the indoor setting temperature or indoor ambient
By pressing this button you can display
temperature.When the indoor unit it will display the setting temperature,
is first powered on
if the temperature's display status is changed from other status to" ",displays the
7
1.Remove the battery cover plate from the rear of the remote controller.
(As shown in the figure)
2.Take out the old batteries.
3.Insert two new AAA1.5V dry batteries, and pay attention to the polarity
(+/-).
4. Reinstall the battery cover plate
Notes:
When replacing the batteries, do not use old or different types of
batteries, it may cause malfunction.
If the remote controller will not be used for a long time, please remove
batteries to prevent batteries from leaking.
Remote should be kept
3 feet
away from the TV set or stereos.
If the remote controller does not operate normally, remove batteries and
reinsert after 30 seconds. If abnormal operation continues,
replace the
batteries.
Diagram for removal of
batteries
Replacement of Batteries
Press "+ " and "- " buttons simultaneously
to lock or unlock the keypad. If the remote
controller is locked, is pressing any button, blinks
three times.
SLEEP:
LIGHT:
16
Press this button to go into the SLEEP operation mode. Press it again to cancel this
Press LIGHT button to turn on the display's light and press this button again to turn off
disappears.
Combination of "+" and "-" buttons: About lock
14
15
or DRY mode to maintain the most
comfortable temperature for you.
Remote Control Instructions
17
Combination of "MODE" and "-" buttons:
, press "MODE"
displayed. In this case,
Allows you to toggle between Fahrenheit and Celsius.
When the unit is OFF
and " - " buttons simultaneously to switch between and .
8
the display's light. If the light is turned on, is displayed. If the light is tunrned off ,
function. This function is available in COOL
9
Emergency operation
If remote controller is lost or damaged, please use auxiliary button to turn
on or turn off the air conditioner. The operation in details are as below:
As shown in the fig. press aux. button to turn on or turn o f the air
conditioner. When the air conditioner is turned on, it will operate under
auto mode.
aux. button
panel
Clean and maintenance
Note:
■ Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.
■ Do not wash the air conditioner with water to avoid electric shock.
■ Do not use volatile liquid to clean the air conditioner.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth
or wet cloth to wipe it.
Note:
● Do not remove the panel when cleaning it.
10
Clean and maintenance
Clean lter
1
2
3
4
Clean lter
Install lter
Open panel
Open panel to access filter.
Remove lter
Remove the filter as
indicated in the fig.
● Use vacuum or water to
clean the filter.
When the filter is very dirty, use
warm water (below 113°F) to
clean it, and then allow to dry.
Install the filter and then close the
panel cover tightly.
Note:
■ The filter should be cleaned every three months. If environment is
excessively dusty more frequent cleaning may be required.
After removing the filte , do not touch fins to avoid injur .
Air dry the filter to avoid deformation or fire hazard.
11
Clean and maintenance
Pre-season check up
Off-season check up
1. Check whether air inlets and air outlets are blocked.
2.
Check whether circuit breaker is in good condition.
3. Check whether filter is clean
4. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
5. Check whether drainage pipe is damaged.
1. Disconnect power supply.
2. Clean filter and indoor unit s panel.
3. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
Notice for disposal of equipment-
1.
Much of packaging is recyclable,check local city/county services for rules
2.
If disposal of air conditioner is required, please contact local dealer or
consult service center for the correct disposal method.
12
Trouble Shooting
Issue
Check items Solution
Indoor unit
not working
with remote.
Or remote
has no
display.
Check batteries
Ensure remote is within
operating distance.
Are there obstacles?
Ensure remote is pointing
directly at "receiving window"
If no display on remote or
display is blurred.
No display when operating
remote controller?
Has remote come into contact with
liquid or been submerged in liquid?
Replace if needed.
Receiving range for signal is
26ft/8m.
Remove obstacles.
Select proper angle and point the
remote controller at the receiving
window on indoor unit.
Check and replace batteries.
If so please discontinue use and
contact dealer for replacment.
Check check for damage to
remote. If damaged please
contact dealer for replacement.
No air
coming
from unit
Is Air inlet or outlet
restricted?
Remove restrictions.
If in heating mode has set
point been reached?
After reaching the set
temperature, indoor fan will
stop blowing.
● Did Heat mode just come on?
Equipment has "Hot start"
feature allowing the unit
outdoor to start first so cold
air is not blown into space.
Prior to calling for service please review troubleshooting section
to eliminate any issues.
13
Trouble Shooting
Has there been a power failure?
Circuit breaker tripping?
Wires not attached?
Unit will not restart after turning
off?
Is remote functioning properly?
If no- See remote
troubleshooting
Wait for 3min, then attempt to
turn on unit. If unit doesn't
restart please call service.
Call for immediate service.
Call servicer or dealer for
licensed professional.
If no check circuit breaker.
Wait for power to be restored.
Air conditioner
not operating
Mist/Fog
coming from
indoor unit
discharge
louvers
Check indoor temprature
and humidity.
Allow unit to run for sometime
Mist/fog should stop once
normal Indoor conditions
stabilize.
Issue
Check items Solution
Cannot adjust
set temprature
Unit operating under Auto
mode.
Temperature can’t be adjusted
while in Auto mode.
Please change operation
modes if needing to change
set point.
Your required temperature
exceeds the set temperature
range.
Set temperature range:
61°F-86°F .
Cooling
temprature
and Heating
temprature
not sufficent
Brownout conditions occured?
Voltage too low.
Wait until power
stabilizes.
Is filter dirty?
Clean the filter.
Set temperature is in proper
range?
Adjust temperature to proper
range.
Door and window are open?
Close door and window.
Allow time for system
to stabilize.
Are there lights on the display?
14
Issue
Check items Solution
Odors
comming
from system
Check for source of odor.
Eliminate the odor
and clean filter.
Check for inclimate weather or
excessive wireless signals.
Power unit down for 3 minutes
and try operation again.
Outdoor unit
has mist/fog
Is system operating in heating?
While in defrost unit may
discharge mist/fog until clear of
moisture.
Noise like
there is water
inside unit
Did air conditioner just come on?
Noise is the sound of
refrigerant flowing inside the
system. Once stabilized
noise will discontinue.
Crackling
sound
Did air conditioner just come on?
Temprature difference between
plastic front and dicharge temp.
may be great once temprature
stabilzes noise will discontinue.
Service and Assistance
Air conditioner
operates
abnormally
1
2
3
Before calling for service, please check the "Basic troubleshooting" section
above. This may help you to find the answer to your problem, avoid unnecessary
service calls, and save the cost of a service call if the problem is not due to the
product itself. If you have checked the "Basic troubleshooting" section and still
need help, below you will find a list of available services:
You can find the name of your local Authorized Service Provider by visiting our
website at www.friedrich.com.
If you require further assistance please call
Friedrich customer support at 1-800-541-6645.
Before calling please make sure that you have the full model and serial number,
as well as the date of purchase of you equipment available. Providing us with this
information will allow us to better assist you.
15
Trouble Shooting
Error code
H1
E5
H4
U8
H6
C5
F1
F2
Troubleshooting
Unit is in defrost mode - This is normal.
Supply voltage was unstable during operation. Please restart, if
restart doesn't work, contact dealer or qualified serivce.
Please contact qualified servicer or dealer.
Please contact qualified servicer or dealer.
Please contact qualified servicer or dealer.
Error Code
When air conditioner status is abnormal, temperature indicator on indoor unit will
blink to display corresponding error code. Please refer to below list for identification
of error code.
Indoor display
Error code
Above indicator diagram is only
for reference. Please refer to
actual product for the actual
indicator and position.
If any of the below occur, please disconnect power and contact qualified
servicer immediately.
● Power cord has overheating or damaged.
● Unit operates loudly or abnormally during operation.
● Circuit breaker trips off frequently.
Air conditioner gives off burning smell.
● Indoor unit is leaking water.
■ Do not repair or refit the air conditioner by yourself
■ If the air conditioner operates under abnormal conditions, it may cause
malfunction, electric shock or fire hazard
Warning
Note: If there're other error codes, please contact qualified professionals for
Indoor component has error. Please restart, if restart doesn't
work, contact dealer or qualified service.
System noticed abnormal temperature range. Please restart, if
restart doesn't work, contact dealer or qualified service.
Indoor component has error. Please restart, if restart doesn't
work, contact dealer or qualified service.
16
Installation dimension diagram
Drainage pipe
At least 8 Ft
At least 6 in
Space to the obstruction
At least 20 in
At least 12 in
At least 12 in
At least 7 Ft
Space to the floo
Space to the
obstruction
Space to the
obstruction
Space to the ceiling
At least 10 Ft
Space to the obstruction
Space to the wall
At least 6 in
At least 12 in
Space to the wall
At least 6 in
Space to the wall
Note *Min/Max
Line Length 10'/82'
17
1.
There should be no obstruction near air inlet
and air outlet.
2.
Location should have acceptable condensate
disposal considerations.
3.
4.
Select a location which is out of reach for
children.
5.
Installed location should be rated for the
weight of equipment and not create
vibration or noise.
6.
The appliance must be installed 8 Ft
above floor.
Do not install directly above heat source or
electrical appliance.
Tools for installation
Selection of installation location
2. Screw driver
1. Level
4. Drill head
7. Open-end wrench
10. Vacuum pump
5. Pipe expander
8. Pipe cutter
11. Manifold gauges
3. Impact drill
6. Torque wrench
9. Leakage detector
12. Multimeter
13. Allen/spanner wrenches 14. Measuring tape
Note:
Please contact a local qualified installer for installation.
Ensure power cords are rated for use with equipment.
Basic requirement
Outdoor unit
Indoor unit
Installing the unit in the following
locations may cause operational issues
with equipment. If unavoidable seek
assistance from local dealer.
1.
Any location with an excessive heat
source, where flammables, gasses or
volitile flyings exist.
2.
Any location with high-frequency
devices (such as welding machine,
medical equipment).
3.Coastal locations.
4.
Corrosive or spaces that are excessivly
wet, such as pool rooms, laundry and
bath rooms.
1.
Be considerate of installed location due to hot airflow from unit and any noise that it
may create.
2.
Location should be well ventilated and dry, outdoor unit not to be exposed
directly to sunlight or strong wind.
3.
The location should be able to withstand the weight of outdoor unit.
4.
Ensure installation conforms to installation diagram.
5.
Select a location which is out of reach for children and far away from animals or
plants. If it is unavoidable, please add the fence for purpose of safety.
18
Requirements for electric connection
Safety precaution
Grounding requirement
1.
Must follow national and regional safety regulations when installing the unit.
2. According to the local safety regulations, use qualified power supply circuit an
circuit breaker.
3. Make sure the power supply matches with the requirement of air conditioner.
Install proper power supply cables before using the air conditioner.
4.
Properly connect all wires.
5. Be sure to cut off the power supply before proceeding any work related to
electricity and safety.
6.
Do not apply voltage until installation is complete.
7.
The temperature of refrigerant circuit will be high, please keep communication
cable clear of copper tubes.
1.
Qualified installer must ensure proper grounding of air conditioner.
2.
The yellow-green wire in air conditioner is the grounding wire. Do not use for any other
purpose.
3.
Grounding should follow national and local electrical regulations.
4.
Air conditioner should be installed so that servicer can access electrical connections.
5.
Local code approved disconnect box must be used.
6.
Including an circuit break with suitable capacity, please note the following table.
Switch should include magnet break and heat break function, this will assist with
protection of circuit.
Models
18/24K
Circuit breaker
25A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

Friedrich MRM24Y3J Mode d'emploi

Catégorie
Climatiseurs split-system
Taper
Mode d'emploi
Ce manuel convient également à

dans d''autres langues