DeWalt DPC16PS Manuel utilisateur

Catégorie
Compresseurs d'air
Taper
Manuel utilisateur

Ce manuel convient également à

DPC6MRC-QS
DPC6MRC-GB
DPC10RC-QS
DPC10RC-GB
DPC10RC-LX
DPC16PS-QS
DPC16PS-GB
DPC16PS-LX
*
English SAFETY & OPERATING INSTRUCTIONS MANUAL
(original instructions) 5
Français MANUEL D'INSTRUCTIONS DE SÉCURITÉ ET D'UTILISATION
(traduction de la notice d’instructions originale) 15
Deutsch SICHERHEITS- UND BEDIENUNGSANLEITUNG
(übersetzt von den Originalanweisungen) 26
Nederlands VEILIGHEIDSHANDLEIDING EN GEBRUIKSAANWIJZING
(vertaald vanuit de originele instructies) 38
Dansk SIKKERHEDS- & BRUGSANVISNING
(oversat fra original brugsvejledning) 49
Suomi TURVALLISUUS- JA KÄYTTÖOHJEET
(käännetty alkuperäisestä käyttöohjeesta) 60
Ελληνικά ΕΓΧΕΙΡΙΔΙΟ ΑΣΦΑΛΕΙΑΣ ΚΑΙ ΟΔΗΓΙΩΝ ΛΕΙΤΟΥΡΓΙΑΣ
(μετάφραση από τις πρωτότυπες οδηγίες) 71
Italiano MANUALE DI SICUREZZA E ISTRUZIONI D'USO
(tradotto dalle istruzioni originali) 83
Norsk BRUKSANVISNING FOR SIKKERHET OG DRIFT
(oversatt fra de originale instruksjonene) 94
Português MANUAL DE INSTRUÇÕES DE FUNCIONAMENTO E DE SEGURANÇA
(traduzido das instruções originais) 105
Español MANUAL DE INSTRUCCIONES Y SEGURIDAD
(traducido de las instrucciones originales) 117
Svenska MANUAL FÖR SÄKERHETS- OCH ANVÄNDARINSTRUKTIONER
(översatt från de ursprungliga instruktionerna) 128
Polski INSTRUKCJA OBSŁUGI I ZASADY BEZPIECZEŃSTWA
(tłumaczenie z wersji oryginalnej) 139
Čeština NÁVOD PRO OBSLUHU A BEZPEČNOST
(překlad originálu) 150
Slovenský BEZPEČNOSTNÝ NÁVOD S POKYNMI
(preklad originálu) 161
Magyar BIZTONSÁGI ÉS ÜZEMELTETÉSI ÚTMUTA
(eredeti szöveg fordítása) 173
Român MANUAL DE INSTRUCȚIUNI PRIVIND UTILIZAREA ȘI SIGURANȚA
(traducerea versiunii originale) 183
Copyright DeWALT
DPC6MRC
Oil Free
Sans huile
Öllos
Olie Vrij
Oliefri
Μη λιπαινόμενος
Senza olio
Sin aceite
Oljefri
Isento de Óleo
Voitelematon
Oljefri
Bezolejowy
Bezolejový
Bezolejový
Olajmentes
1
2
3
4
5
6
7
9
7
4
9
3
1
9
5
6
14
2
DPC10RC
Oil Lubricated
Lubrifié
Ölgeschmiert
Olie Gesmeerd
Oliesmurt
Λιπαινόμενος
Lubrificato ad olio
Lubricado con aceite
Oljesmurt
Lubrificado a Óleo
Voideltu
Oljesmord
Olejowy
Mazaný olejem
Mazaný olejom
Olajkenésű kompresszor
DPC16PS
10
131214 17
1
8
7
2
15
5
16
9
3
46
11
GB FR DE NL
1 TANK RÉSERVOIR KESSEL TANK
2DRAIN VALVE DRAIN VALVE ABLASSVENTIL AFVOERKLEP
3COMPRESSED AIR OUTLET SORTIE AIR COMPRIMÉ DRUCKLUFTAUSGANG AFVOER PERSLUCHT
4PRESSURE REDUCER RÉDUCTEUR DE PRESSION DRUCKMINDERER DRUKREGELAAR
5 HANDLE POIGNÉE GRIFF HANDVAT
6PRESSURE SWITCH PRESSOSTAT EIN/AUS-SCHALTER /DRUCKWÄCHTER DRUKSCHAKELAAR
7 GUARD CARTER DE PROTECTION SCHUTZVERKKLEIDUNG SCHERM
8 WHEEL ROUE RAD WIEL
9PRESSURE GAUGE MANOMÈTRE MANOMETER MANOMETER
10 AIR FILTER FILTRE A AIR LUFTFILTER LUCHTFILTER
11 THERMAL-BREAKER MAGNÉTOTHERMIQUE THERMOSICHERUNG THERMISCHE ONDERBREKER
12 LIFT POINTS LIFT POINTS HEBESTELLEN HEFPUNTEN
13 DIPSTICK TIGE DE NIVEAU D’HUILE ÖLMESSTAB PEILSTOK
14 SAFETY VALVE SAFETY VALVE SICHERHEITSVENTIL VEILIGHEIDSKLEP
15 HANDLE ADJUSTMENTS AJUSTMENTS POIGNÉE GRIFFVERSTELLUNG HANDVATINSTELLINGEN
16 CABLE AND HOSE TIDY SYSTEME POUR LE CABLE ET LE TUYAU KABEL- UND SCHLAUCHAUFWICKLUNG KABEL- EN SLANGHASPEL
17 OIL DRAIN VALVE OIL DRAIN VALVE ÖLABLASSVENTIL OLIEAFVOERKLEP
DK GR IT ES
1 BEHOLDER
ΔΕΞΑΜΕΝΗ
SERBATOIO DEPÓSITO
2 AFLØBSVENTIL
ΒΑΛΒΙΔΑ ΑΠΟΣΤΡΑΓΓΙΣΗΣ
VALVOLA DI DRENAGGIO VÁLVULA DE DRENAJE
3UDGANG FOR TRYKLUFT
ΣΤΟΜΙΟ ΕΞΟΔΟΥ ΠΕΠΙΕΣΜΕΝΟΥ ΑΕΡΑ
SCARICO ARIA COMPRESSA SALIDA DE AIRE COMPRIMIDO
4TRYKBEGRÆNSER
ΑΠΟΣΥΜΠΙΕΣΤΗΣ
RIDUTTORE DI PRESSIONE REDUCTOR DE PRESIÓN
5 GREB
ΛΑΒΗ
MANIGLIA MANGO
6PRESSOSTATKONTAKT
ΔΙΑΚΟΠΤΗΣ ΠΙΕΣΗΣ
PRESSOSTATO PRESOSTATO
7 AFSKÆRMNING
ΠΕΡΙΒΛΗΜΑ ΠΡΟΣΤΑΣΙΑΣ
PROTEZIONE COBERTURA DE PROTECCIÓN
8 HJUL
ΤΡΟΧΟΣ
RUOTA RUEDA
9 TRYKMÅLER
ΜΕΤΡΗΤΗΣ ΠΙΕΣΕΩΣ
MANOMETRO MANÓMETRO
10 LUFTFILTER
ΦΙΛΤΡΟ ΑΕΡΑ
FILTRO DELL'ARIA FILTRO DE AIRE
11 TERMISK AFBRYDER
ΘΕΡΜΙΚΟΣ ΔΙΑΚΟΠΤΗΣ
INTERRUTTORE MAGNETO-TERMICO MAGNETOTÉRMICO
12 LØFTE PUNKTER
ΣΗΜΕΙΑ ΑΝΥΨΩΣΗΣ
PUNTI DI SOLLEVAMENTO PUNTOS DE ELEVACIÓN
13 OLIEPIND
ΡΑΒΔΟΣ ΜΕΤΡΗΣΗΣ ΣΤΑΘΜΗΣ ΛΑΔΙΟΥ
ASTA DI LIVELLO DELL'OLIO VARILLA DEL NIVEL DE ACEITE
14 SIKKERHEDSVENTIL
ΒΑΛΒΙΔΑ ΑΣΦΑΛΕΙΑΣ
VALVOLA DI SICUREZZA VÁLVULA DE SEGURIDAD
15 JUSTERING AF GREB
ΡΥΘΜΙΣΕΙΣ ΛΑΒΗΣ
DISPOSITIVI DI REGOLAZIONE MANIGLIA AJUSTES DEL MANGO
16 KABEL OG SLANGE OPRUL
ΤΑΚΤΟΠΟΙΗΣΗ ΚΑΛΩΔΙΩΝ ΚΑΙ ΣΩΛΗΝΩΝ
CONTENIMENTO CAVO E MANICHETTA RECOGECABLES Y MANGUERA
17 OLIE AFLØBSVENTIL
ΒΑΛΒΙΔΑ ΑΠΟΣΤΡΑΓΓΙΣΗΣ ΛΑΔΙΟΥ
VALVOLA DI DRENAGGIO DELL'OLIO VÁLVULA DE DRENAJE DE ACEITE
NO PT FI SE
1 TANK DEPÓSITO SÄILIÖ TANK
2 AVTAPPINGSVENTIL VÁLVULA DE DRENAGEM TYHJENNYSVENTTIILI DRÄNERINGSVENTIL
3 TRYKKLUFTUTGANG SAÍDA DE AR COMPRIMIDO PAINEILMALÄHTÖ TRYCKLUFTSUTGÅNG
4 TRYKKFORMINSKER REDUTOR DE PRESSÃO PAINEENALENTAJA TRYCKLUFTSREDUCERARE
5 HÅNDTAK PEGA KAHVA HANDTAG
6 TRYKKBRYTER INTERRUPTOR DE PRESSÃO PAINEKYTKIN TRYCKBRYTARE
7 VERNEINNRETNING PROTEÇÃO SUOJUS SKYDD
8 HJUL RODA PYÖRÄ HJUL
9 TRYKKMÅLER INDICADOR DE PRESSÃO PAINEMITTARI TRYCKMÄTARE
10 LUFTFILTER FILTRO DE AR ILMANSUODATIN LUFTFILTER
11 TERMOBRYTER DISJUNTOR TÉRMICO LÄMPÖKATKAISIN TERMISK BRYTARE
12 LØFTEPUNKTER PONTOS DE ELEVAÇÃO NOSTOKOHDAT LYFTPUNKTER
13 OLJEPEILEPINNEN VARETA ÖLJYN MITTATIKKU OLJEMÄTSTICKA
14 SIKKERHETSVENTIL VÁLVULA DE SEGURANÇA VAROVENTTIILI SÄKERHETSVENTIL
15 JUSTERING AV HÅNDTAK REGULADORES DA PEGA KAHVAN SÄÄDÖT HANDTAGSJUSTERINGAR
16 KABEL- OG SLANGEHOLDER ENROLADORES DO CABO E DA MANGUEIRA KAAPELEIDEN JA LETKUJEN SIISTIMINEN SLANG- OCH KABELVINDA
17 OLJEAVTAPPINGSVENTIL VÁLVULA DE DRENAGEM DO ÓLEO ÖLJYN TYHJENNYSVENTTIILI OLJEDRÄNERINGSVENTIL
PL CZ SK HU RO
1
ZBIORNIK NÁDRŽ TLAKOVÁ NÁDOBA TARTÁLY REZERVOR
2
ZAWÓR SPUSTOWY ODTAH KONDENZÁTU VÝPUSTNÝ VENTIL LEERESZTŐSZELEP SUPAPĂ DE DRENARE
3
DYSZA WYLOTOWA VÝSTUP STLAČENÉHO
VZDUCHU VÝVOD STLAČENÉHO
VZDUCHU SŰRÍTETTLEVEGŐ-KIMENET ORIFICIU DE EVACUARE AER
COMPRIMAT
4
REGULATOR CIŚNIENIA REDUKTOR TLAKU REGULÁTOR TLAKU NYOMÁSCSÖKKENTŐ REDUCTOR DE PRESIUNE
5
RĄCZKA RUKOJEŤ RUKOVÄŤ MARKOLAT MÂNER
6
WYŁĄCZNIK CIŚNIENIOWY TLAKOVÝ SPÍNAČ TLAKOVÝ SPÍNAČ NYOMÁSKAPCSOLÓ COMUTATOR DE PRESIUNE
7
POKRYWA OCHRANA KRYT VÉDŐ PROTECȚIE
8
KOŁO KOLO KOLESO KERÉK ROATĂ
9
MANOMETR TLAKOMĚR MANOMETER NYOMÁSMÉRŐ MŰSZER MANOMETRU
10
FILTR POWIETRZA VZDUCHOVÝ FILTR VZDUCHOVÝ FILTER LEVEGŐSZŰRŐ FILTRU DE AER
11
WYŁĄCZNIK TERMICZNY TEPELNÝ JISTIČ TEPELNÝ ISTIČ HŐKIOLDÓ BIZTOSÍTÉK SIGURANȚĂ TERMICĂ
12
MIEJSCA CIĄGU MÍSTA UCHYCENí PŘI ZVEDÁNÍ DVÍHACIE RUKOVÄTE EMELÉSI PONTOK PUNCTE DE RIDICARE
13
WSKAŹNIK POZIOMU OLEJU MĚRKA KONTROLNÁ MIERKA
HLADINY OLEJA OLAJPÁLCA JOJĂ
14
ZAWÓR BEZPIECZEŃSTWA POJISTNÝ VENTIL POISTNÝ VENTIL BIZTONSÁGI SZELEP SUPAPĂ DE SIGURANȚĂ
15
USTAWIENIA RĄCZKI NASTAVENÍ RUKOJETI ÚPRAVY RUKOVÄTE MARKOLATBEÁLLÍTÁSOK REGLAJE MÂNER
16
SCHOWEK NA KABEL I
PRZEWÓD DRŽÁK NA KABEL A HADICI SCHRÁNKA NA KÁBEL A
HADICU KÁBEL- ÉS TÖMLŐTARTÓ SISTEM PENTRU CABLU
ȘI FURTUN
17 ZAWÓR SPUSTOWY OLEJU VENTIL ODPOUŠTĚNÍ OLEJE VÝPUSTNÝ VENTIL OLEJA OLAJLEERESZTŐ-SZELEP
SUPAPĂ DE DRENARE
A ULEIULUI
ENGLISH
7
Read the Instruction Handbook:
Before positioning, operating or adjusting the
compressor, read the instruction book carefully.
MARKINGS ON TOOL
The following pictograms are shown on the tool:
RISK OF ELECTRIC SHOCK:
CAUTION: before doing any work on the compressor, it
must be disconnected from the power supply.
RISK OF HIGH TEMPERATURES:
CAUTION: the compressor contains some parts which
might reach high TEMPERATURES.
RISK OF ACCIDENTAL START-UP:
Attention: the compressor could start automatically in
case of a black-out and subsequent reset.
WEAR EAR PROTECTION
IMPORTANT INFORMATION
Read and understand all of the operating instructions, safety
precautions and warnings in the Instruction Manual before
operating or maintaining this compressor. Most accidents
that result from compressor operation and maintenance
are caused by the failure to observe basic safety rules or
precautions. An accident can often be avoided by recognizing
a potentially hazardous situation before it occurs, and by
observing appropriate safety procedures. Basic safety
precautions are outlined in the “SAFETY” section of this
Instruction Manual and in the sections which contain the
operation and maintenance instructions. Hazards that must
be avoided to prevent bodily injury or machine damage
are identified by WARNINGS on the compressor and in this
Instruction Manual.
Use the DeWALT compressor only for the purpose for
which it was designed, such as: pneumatic nailing tools,
paint spraying, tyre inflating etc.. Always ensure that the
tool you are connecting has a suitable air pressure value.
MEANINGS OF SIGNAL WORDS
m WARNING: indicates a potentially hazardous situations
which, if ignored, could result in serious personal injury.
m CAUTION: indicates a hazardous situations which, if
ignored, could result moderate personal injury, or could cause
machine damage.
NOTE: emphasizes essential information
Safety instructions
IMPORTANT SAFETY INSTRUCTIONS FOR USE OF THE
COMPRESSOR.
m WARNING: DEATH OR SERIOUS BODILY INJURY
COULD RESULT FROM IMPROPER OR UNSAFE USE OF
COMPRESSOR. TO AVOID THESE RISKS, FOLLOW THESE
BASIC SAFETY INSTRUCTIONS.
READ ALL INSTRUCTIONS
1. NEVER TOUCH MOVING PARTS Never place your hands,
fingers or other body parts near the compressor’s moving
parts.
2. NEVER OPERATE WITHOUT ALL GUARDS IN PLACE
Never operate this compressor without all guards or safety
features in place and in proper working order. If maintenance
or servicing requires the removal of a guard or safety
features, be sure to replace the guards or safety feature
before resuming operation of the compressor.
3. ALWAYS WEAR EYE PROTECTION Always wear safety
goggles or equivalent eye protection. Compressed air must
never be aimed at anyone or any part of the body.
4. PROTECT YOURSELF AGAINST ELECTRIC SHOCK
Prevent body contact with grounded surfaces such as pipes,
radiators, ranges and refrigeration enclosures. Never operate
the compressor in damp or wet locations. Never leave the
appliance exposed to adverse weather conditions.
5. DISCONNECT THE COMPRESSOR Always disconnect
the compressor from the power source and remove the
compressed air from the air tank before servicing, inspecting,
maintaining, cleaning, replacing or checking any parts.
6. AVOID UNINTENTIONAL STARTING Do not carry the
compressor while it is connected to its power source or when
the air tank is filled with compressed air. Be sure the knob of
the pressure switch in the “OFF” position before connecting
the compressor to its power source.
7. STORE COMPRESSOR PROPERLY When not in use, the
compressor should be stored in dry place. Keep out of reach
of children. Lock-out the storage area.
8. KEEP WORK AREA CLEAN Cluttered areas invite injuries.
Clear all work areas of unnecessary tools, debris, furniture
etc…
9. KEEP CHILDREN AWAY Do not let visitors contact
compressor extension cord. All visitors should be kept safely
away from work area.
10. DRESS PROPERLY Do not wear loose clothing or
jewellery. They can be caught in moving parts. Wear
protective hair covering to contain long hair.
11. DON’T ABUSE CORD Never yank it to disconnect from
receptacle. Keep cord from heat, oil and sharp edges.
12. MAINTAIN COMPRESSOR WITH CARE Follow
instructions for lubricating. Inspect cords periodically and if
damaged, have repaired by authorized service facility. Inspect
extension cords periodically and replace if damaged.
13. OUTDOOR USE EXTENSION CORDS When compressor
in used outdoors, use only extension cords intended for use
outdoors and so marked.
14. STAY ALERT Watch what you are doing. Use common
sense. Do not operate compressor when you are tired.
compressor should never be used by you if you are under
ENGLISH
8
the influence of alcohol, drugs or medication that makes you
drowsy.
15. CHECK FOR DAMAGED PARTS AND AIR LEAKS
Before further use of the compressor, carefully checked
the guard and other parts for damage to make sure that
it will operate properly and perform its intended function.
Check for alignment of moving parts, binding of moving
parts, breakage of parts, mounting, air leak, and any other
conditions that may affect its operation. A guard or other
part that is damaged should be properly repaired or replaced
by an authorized service center unless otherwise indicated
elsewhere in this Instruction Manual. Have defective pressure
switches replaced by authorized service center. Do not use
compressor if switch does not turn it on and off.
16. NEVER USE COMPRESSOR FOR APPLICATIONS
OTHER THAN THOSE SPECIFIED Never use compressor
for applications other than those specified in the Instruction
Manual. Never use compressed air for breathing or
respiration. Never stand on the compressor.
17. HANDLE COMPRESSOR CORRECTLY Operate the
compressor according to the instructions provided herein.
Never allow the compressor to be operated by children,
individuals unfamiliar with its operation or unauthorized
personnel.
18. KEEP ALL SCREWS, BOLTS AND COVERS TIGHTLY IN
PLACE Keep all screws, bolts, and plates tightly mounted.
Check their conditions periodically.
19. KEEP MOTOR AIR VENT CLEAN The motor air vent must
be kept clean so that air can freely flow at all times. Check for
dust build-up frequently.
20. OPERATE COMPRESSOR AT THE RATED VOLTAGE
Operate the compressor at voltages specified on their
nameplates. If using the compressor at a higher voltage
than the rated voltage, it will result in abnormally fast motor
revolution and may damage the unit and burn out the motor.
21. NEVER USE A COMPRESSOR WHICH IS DEFECTIVE OR
OPERATING ABNORMALLY If the compressor appears to
be operating unusually, making strange noises, or otherwise
appears defective, stop using it immediately and arrange for
repairs by an authorized service center.
22. DO NOT WIPE PLASTIC PARTS WITH SOLVENT Solvents
such as gasoline, thinner, benzine, carbon tetrachloride, and
alcohol may damage and crack plastic parts. Do not wipe
them with such solvents. Wipe plastic parts with a soft cloth
lightly dampened with soapy water and dry thoroughly.
23. USE ONLY GENUINE REPLACEMENT PARTS
Replacement parts not original may void your warranty and
can lead to malfunction and resulting injuries. Genuine parts
are available from your dealer.
24. DO NOT MODIFY THE COMPRESSOR Do not modify the
compressor. Always contact the authorized service center
any repairs. Unauthorized modification may not only impair
the compressor performance but may also result in accident
or injury to repair personnel who do not have the required
knowledge and technical expertise to perform the repair
operations correctly.
25. TURN OFF THE PRESSURE SWITCH WHEN THE
COMPRESSOR IS NOT USED When the compressor is not
used, turn the knob of the pressure switch OFF, disconnect it
from the power source and open the drain cock to discharge
the compressed air from the air tank.
26. NEVER TOUCH HOT SURFACE To reduce the risk of
burns, do not touch tubes, heads, cylinder and motors.
27. DO NOT DIRECT AIR STREAM AT BODY Risk of injury,
do not direct air stream at persons or animals.
28. DRAIN TANK Drain tank daily or after 4 hours of use.
Open drain fitting and tilt compressor to empty accumulated
water.
29. DO NOT STOP COMPRESSOR BY PULLING OUT THE
PLUG Use the “AUTO/OFF” knob of pressure switch.
30. USE ONLY RECOMMENDED AIR HANDLING PARTS
ACCEPTABLE FOR PRESSURE NOT LESS THAN 8.6 BAR
(125 PSI) Risk of bursting. Use only recommended air
handling parts acceptable for pressures not less than 8.6 bar
(125 psi).
31. WEAR PROPER HEARING AND HEAD PROTECTION
Suitable protective clothing must be worn when operating the
compressor and connected tool or accessory. Consult the tool
/ accessory manual and adhere to any safety requirements.
32. MAKE ALLOWANCE FOR ENVIRONMENTAL
CONDITIONS
Never leave the compressor in the rain. Never use the
compressor in damp or wet conditions. Provide good lighting.
Never use the compressor near combustible liquids or gases.
REPLACEMENT PARTS
When servicing use only identical replacement parts. Repairs
should be conducted only by authorized service center.
EXTENSION CORD
Use only three-extension cords that have three-prong
grounding type plugs and three-pole receptacles that accept
the compressor’s plug. Replace or repair damaged cord.
Make sure your extension cord is in good condition. When
using an extension cord, be sure to use one heavy enough to
carry the current your product will draw. An undersized cord
will cause a drop in line voltage resulting in loss of power and
overheating. Table shows the correct size to use depending
on cord length and name plate ampere rating. If in doubt,
use the next heavier gage. The smaller the gage number, the
heavier the cord.
When operating a power tool outdoors, use an extension cord
suitable for outdoor use. Use of a cord suitable for outdoor
use reduces the risk of electric shock.
ENGLISH
9
SECTION VALID FOR A MAX LENGTH
OF 20m SINGLE-PHASE
Power / HP Power / kW 220/230V mm2 110/120V mm2
0.75-1 0.65-0.7 1.5 2.5
1.5 1.1 2.5 4
2 1.5 2.5 4-6
2.5-3 1.8-2.2 4 -
m WARNING Avoid electrical shock hazard. Never use this
compressor with a damaged or frayed electrical cord or
extension cord. Inspect all electrical cords regularly. Never
use in near water or in any environment where electric shock
is possible.
SAFETY VALVE
This compressor is equipped with a safety valve that is set to
avoid over-pressurization of the air tanks. This valve is factory
pre-set and will not function unless tank pressure reaches
this pressure.
m WARNING: DO NOT ATTEMPT TO ADJUST OR
ELIMINATE THIS SAFETY DEVICE. ANY ADJUSTMENTS TO
THIS VALVE COULD CAUSE SERIOUS INJURY. If this device
requires service or maintenance, see an Authorized DeWALT
Service Center.
Attachments and Accessories:
For any attachment or accessory you will be using with this
compressor, the maximum allowable recommended pressure
should be clearly marked on the product or should be clearly
noted within the operations manual. Exceeding the pressure
rating of these attachments (including, but not limited to:air
tools, air operated accessories, spray guns, air hose, air hose
connections, tires and other inflatables) could cause them to
fly apart or explode and could result in serious injury.
Never exceed the maximum allowable pressure
recommended by the manufacturer of any attachment or
accessory you use with this compressor.
DUTY CYCLE:
To ensure long life of your DeWALT air compressor, do
not operate on more than the duty cycle indicated on the
technical data plate. If, for example, this air compressor
pumps air more than 25% of one hour, then the
compressor’s capability is less than the air delivery required
by the application. Always match the air volume requirements
of the attachment or accessory with the air volume delivery of
the compressor.
To avoid overheating of the electric motor, this compressor
is designed for intermittent operation as indicated on the
technical dataplate (for example, S3-25 means 2.5 minutes
ON, 7.5 minutes OFF).
SAVE THESE INSTRUCTIONS AND MAKE THEM
AVAILABLE TO OTHER USERS OF
THIS TOOL!
OPERATION AND MAINTENANCE
NOTE: The information contained in this Instruction Manual is
designed to assist you in the safe operation and maintenance
of the compressor. Some illustrations in this Instruction
Manual may show details or attachments that differ from
those on your own compressor.
INSTALLATION
Remove the compressor from its packing, makes sure it
is in perfect condition, checking if it was damaged during
transport, and carry out the following operations:
DPC16PS ONLY
m Caution: Risk of personal injury. Avoid placing hands
between handle and top panel when assembling to
prevent pinching.
1. Place handle (5) into bushings on top panel (7).
2. Depress snap buttons and slide handle through first
bushings until it stops at second bushings.
3. Reach under top panel and depress snap buttons again
and slide through second bushings.
4. Pull handle all the way up until it stops. Turn knobs (15) to
lock handle in place. IMPORTANT: Always pull handle up
and lock in place before using as a dolly.
5. If not using the dolly feature, loosen knobs and push
handle down until it stops.
LUBRICATION AND OIL - DPC16PS ONLY
m CAUTION: The compressor was shipped with oil in the
crankcase. Please check carefully if the oil is at the right
level. Do not attempt to operate this air compressor without
first checking the oil level in the crankcase. Serious damage
can result from even limited operation unless filled with oil
and broken in correctly. Closely follow Initial Set-up under
Operation having completed all required steps.
m Caution: Multi-viscosity motor oils, like 10W30, should
not be used in an air compressor. They leave carbon deposits
on critical components, thus reducing performance and
compressor life. Use DeWALT synthetic or SAE 40, non-
detergent air compressor oil.
1. Place unit on a level surface.
2. Remove dipstick (13) and check oil level. Gradually
add DeWALT synthetic or SAE 40, non-detergent air
compressor oil if required. NOTE: See Specifications for
pump oil capacity.
m Caution: Risk of unsafe operation. Overfilling with oil will
cause premature compressor failure. Do not overfill.
3. Reposition dipstick.
NOTE: Some units (DPC6MRC, DPC10RC) are equipped
with an oil-free pump. There is no oil to replace or check.
ENGLISH
10
ELECTRICAL CONNECTION
Do not abuse the cord. Never use the cord for carrying,
pulling or unplugging the power tool. Keep cord away
from heat, oil, sharp edges or moving parts.
Damaged or entangled cords increase the risk of electric
shock.
Single-phase compressors are supplied with an electrical
cable and a two-pole & earth plug. The compressor must be
connected to a grounded power socket.
IMPORTANT: Never use the ground socket instead of the
neutral wire. The ground connection must be made to
meet safety standards (EN 60204). The plug of the power
cable must not be used as a switch, but must be fitted in
a power socket controlled by a suitable differential switch
(thermalbreaker).
m DANGER: RISK OF ELECTRICAL SHOCK. IMPROPER
GROUNDING CAN RESULT IN ELECTRICAL SHOCK.
Do not modify the plug provided. If it does not fit the available
outlet, a correct outlet should be installed by a qualified
electrician.
Repairs to the cord set or plug MUST be made by a qualified
electrician.
PREPARATION FOR USE
PRE-START CHECKLIST
1. Ensure the On/Off switch (6) is in the OFF position.
2. Plug the power cord into the correct branch circuit
receptacle. See Electrical Connection (above).
3. Ensure air tank is drained, see Draining Air Tank under
Maintenance.
4. Ensure the drain valve (2) is closed.
5. Ensure safety valve (14) is functioning properly, see
Checking Safety Valve under Maintenance.
6. Check pump oil level, see Compressor Pump Oil under
Maintenance. (DPC16PS Only)
m CAUTION: Do not operate without oil or with inadequate
oil. DeWALT is not responsible for compressor failure
caused by inadequate oil.
7. Turn regulator knob (4) counterclockwise until fully closed.
Ensure regulated pressure gauge reads 0 bar (0 psi).
8. Attach hose and accessories.
m Warning: Risk of unsafe operation. Firmly grasp hose in
hand when installing or disconnecting to prevent hose
whip.
9. Ensure all covers and labels are in place, legible (for labels)
and securely mounted. Do not use compressor until all
items have been verified.
m Warning: Risk of bursting. Too much air pressure causes
a hazardous risk of bursting. Check the manufacturer’s
maximum pressure rating for air tools and accessories.
The regulator outlet pressure must never exceed the
maximum pressure rating.
INITIAL SET-UP
m Warning:Do not operate this unit until you read and
understand this instruction manual for safety, operation
and maintenance instructions.
BREAK-IN PROCEDURE
m CAUTION: Risk of property damage. Serious damage may
result if the following break-in instructions are not closely
followed.
This procedure is required before the air compressor is put
into service for the first time and when the check valve or a
compressor pump/motor has been replaced.
1. Ensure the On/Off switch (6) is in the OFF position.
NOTE: If hose is not connected to Quick Connect body, pull
coupler back until it clicks to prevent air from escaping
through the quick connect.
2. Plug the power cord into the correct branch circuit
receptacle. See Voltage and Circuit Protection under
Installation.
3. Open the drain valve (counter-clockwise) fully to permit air
to escape and prevent air pressure build up in the air tank
during the break-in period.
4. Move the On/Off switch to the ON position. The compressor
will start.
5. Run the compressor for 20 minutes.
6. After 20 minutes, close the drain valve by turning
clockwise. The tank will fill to cut-out pressure and the
motor will stop.
7. Compressed air will be available until it is used or bled off.
STARTING
Check that the mains power matches that indicated on the
electrical data-plate - the permissible tolerance range is
+/-5%. Turn or press into position “0”. Fit the plug in the
power socket and start the compressor, turning the pressure
switch knob into position “I”.
The compressor is fully automatic, and is controlled by
the pressure switch which stops it when tank pressure
reaches maximum value and restarts it when it falls to
minimum value. The pressure difference between maximum
and minimum values is usually about 2 bar (29 psi). E.g.:
the compressor stops when it reaches 8 bar (116 psi) -
maximum operating pressure) and restarts automatically
when the pressure inside the tank drops to 6 bar (87 psi).
After connecting the compressor to the power line, load it to
maximum pressure and check exactly how the machine is
operating.
NOTE: The head/cylinder/delivery tube unit can reach high
temperatures. Take care when working near these parts, and
do not touch them to avoid possible burns.
IMPORTANT
The electro-compressors must be connected to a power
socket protected by a suitable differential switch (thermal-
breaker). The motor is equipped with an automatic
ENGLISH
11
thermal breaker located inside the winding - this stops the
compressor when motor temperature reaches excessively
high values (180oC). If the breaker is tripped, the compressors
restart automatically after 10 to 15 minutes.
ADJUSTING OPERATING PRESSURE
You do not have to use the maximum operating pressure
at all times. On the contrary, the pneumatic tool being used
often requires less pressure. On compressors supplied with
a pressure reducer, operating pressure must be correctly
adjusted.
Adjust pressure to the required value by turning the knob (4)
clockwise to increase pressure and anti-clockwise to reduce
it. When you have obtained optimum pressure, lock the knob
by pressing it downward. For pressure reducers equipped
without a pressure gauge, the set pressure can be seen on
the graduated scale located on the reducer body.
On pressure reducers equipped with a pressure gauge,
pressure can be seen on the gauge itself.
WARNING: Some pressure regulators do not have “push to
lock”, therefore simply turn the knob to adjust the pressure.
STOPPING THE COMPRESSOR
1. Turn or press the switch/button into position “0” (according
to the type of pressure switch fitted on the compressor).
DO NOT turn off the unit by switching off at the socket or
pulling out the plug.
2. Turn regulator knob (4) counterclockwise until fully closed.
Ensure regulated pressure gauge reads 0 bar (0 psi).
3. Remove hose and accessory.
4. Drain the air tank, see Draining Air Tank under Maintenance.
Ensure air tank pressure gauge reads 0 bar (0 psi).
Maintenance
m WARNING: To reduce the risk of injury, turn unit off and
disconnect machine from power source before installing and
removing accessories, before adjusting or changing setups or
when making repairs.
An accidental start-up can cause injury.
The following procedures must be followed when
maintenance or service is performed on the air compressor.
NOTE: Allow air compressor to cool down before starting
service.
NOTE: All compressed air systems contain maintenance parts
(e.g., oil, filters, separators) that are periodically replaced.
These used parts may contain substances that are regulated
and must be disposed of in accordance with local, state, and
federal laws and regulations.
NOTE: Take note of the positions and locations of parts during
disassembly to make reassembly easier.
NOTE: Any service operations not included in this section
should be performed by a DeWALT factory service center or a
DeWALT authorized service center.
DRAINING AIR TANK
The condensation in the tank must be drained daily by
opening the drain tap (2) under the tank. Take care if there is
compressed air inside the cylinder, as water could flow out
with considerable force.
1. Verify that the compressor is turned “Off”.
2. Holding the handle, tilt the compressor toward the drain
valve so it is positioned at the bottom of the tank.
3. Turn the drain valve to open.
4. Keep the compressor tilted until all moisture has been
removed.
MAINTENANCE CHART
Procedure Daily Weekly Monthly 1 year or 200 Hours
Check safety valve
X
Inspect air filter +
X
Drain air tank
X
Check pump oil level
X
Change pump oil (DPC16PS Only)**+
X
Oil leak inspection (DPC16PS Only)
X
Check for unusual noise/vibration
X
Check for air leaks*
X
Clean compressor exterior
X
* To check for air leaks apply a solution of soapy water around joints. While compressor is pumping to pressure and after pressure
cuts out, look for air bubbles to form.
** The pump oil must be changed after the first 20 hours of operation. Thereafter, when using DeWALT synthetic or SAE 40, non-
detergent air compressor oil, change oil every 200 hours of operation or once a year, whichever comes first.
+
Perform more frequent in dusty or humid conditions
ENGLISH
12
Condensation of compressors that are oil lubricated must not
be drained into the sewer or dispersed in the environment as
it contains oil.
CHECKING SAFETY VALVE (14)
m WARNING: Hot surfaces. Risk of burn. Aftercooler, pump
head, and surrounding parts are very hot, do not touch. Allow
compressor to cool prior to servicing.
m WARNING: Risk of bursting. If the safety valve does not
work properly, over-pressurization may occur, causing air
tank rupture or an explosion.
Before starting compressor, pull the ring on the safety valve
to make sure that the safety valve operates freely. If the valve
is stuck or does not operate smoothly, it must be replaced
with the same type of valve.
CHECKING AIR FILTER ELEMENT (10)
m WARNING: Hot surfaces. Risk of burn. Aftercooler, pump
head, and surrounding parts are very hot, do not touch . Allow
compressor to cool prior to servicing.
1. Ensure the On/Off switch (6) is in the OFF position.
2. Allow unit to cool.
3. Remove air filter (10) from unit.
4. Carefully pry filter top from base.
5. Remove element from filter base.
6. If element needs cleaning, blow out with air. Replace if needed.
Purchase replacement parts from your local dealer or authorized
service center. Always use identical replacement parts.
7. Place element back in filter base.
8. Snap filter top to filter base.
9. Reassemble air filter to unit. Ensure exhaust outlet points down.
m CAUTION: Risk of unsafe operation. Do not operate without
air inlet filter.
COMPRESSOR PUMP OIL (DPC16PS ONLY)
CHECKING OIL
m WARNING: Hot surfaces. Risk of burn. Aftercooler, pump
head, and surrounding parts are very hot, do not touch . Allow
compressor to cool prior to servicing.
1. Ensure On/Off switch is in the OFF position.
2. Place unit on a flat level surface.
3. Remove dipstick (13) and wipe clean.
4. Reinsert dipstick fully into oil fill port for a few seconds to
allow oil to collect on the dipstick.
5. Remove oil dipstick to read oil level. Oil should not exceed
top raised line on dipstick. If oil is below lower mark, add
same type of oil in crankcase and follow Steps 4 - 6.
NOTE: When filling the crankcase, the oil flows very slowly
into the pump. If the oil is added too quickly, it will overflow
and appear to be full.
m CAUTION: Risk of unsafe operation. Overfilling with oil will
cause premature compressor failure. Do not overfill.
6. Replace dipstick.
CHANGING OIL
NOTE: Pump oil contains substances that are regulated and
must be disposed of in accordance with local, state and
federal laws and regulations.
m WARNING: Hot surfaces. Risk of burn. Aftercooler, pump
head, and surrounding parts are very hot, do not touch . Allow
compressor to cool prior to servicing.
1. Ensure On/Off switch is in the OFF position.
2. Allow the unit to cool.
3. Remove air compressor plug from outlet.
4. Drain air tank.
5. Locate a suitable container under pump drain plug (17).
6. Remove the dipstick (13) from crank case.
7. Remove the oil drain plug (17).
8. Allow ample time for all oil to drain out. (Tilting the
compressor towards the drain plug will assist in draining.)
9. Install the oil drain plug.
10. Fill pump using DeWALT synthetic or SAE 40, non-
detergent air compressor oil.
11. Replace dipstick.
WHAT TO DO IF SMALL
MALFUNCTIONS OCCUR
Loss of air in valve under pressure switch
This trouble depends on poor tightness of the check valve.
Take the following action:
- Discharge all pressure from the tank
- Unscrew the hexagon-head of the valve
- Carefully clean both the rubber disk and its seat.
- Refit all parts accurately.
Air losses
These can be caused by poor tightness of a union - check all
unions, wetting them with soapy water.
Compressor not starting
If the compressor has trouble starting, check the following :
- Does mains power match that of the data-plate?
- Are power cable extensions of adequate diameter or length?
- Is the work environment too cold? (under 0°C)
- Is there oil in the housing to ensure lubrication?
- Is power supplied to the electrical line? (sockets well
connected, thermal- breaker, fuses in good condition
ENGLISH
13
Compressor not stopping
- If the compressor does not stop when maximum pressure
is reached, the tank safety valve comes into operation. A
compressor with a faulty safety valve must NEVER be used
- contact your nearest service centre immediately.
IMPORTANT
- Do not on any account unscrew any connection while the
tank is pressurised
- Always check if the tank is pressure free.
- Do not drill holes, weld or purposely deform the compressed
air tank.
- Do not do any jobs on the compressor unless you have
disconnected the power plug.
- Temperature in operating ambient: 0°C +35°C.
- Do not aim jets of water or inflammable liquids on the
compressor.
- Do not place flammable objects near the compressor.
- During down-times, turn the pressure switch to position
“0” (OFF).
- Never aim the air jet at people or animals
- Do not transport the compressor while the tank is
pressurised.
- Be careful with regard to some parts of the compressor
such as the head and delivery tubes, as they can reach high
temperatures. Do not touch these parts to avoid burns.
- Transport the compressor, lifting or pulling it with the
appropriate grips or handles
- Keep children and animals well away from the machine
operating area.
- If using the compressor for painting: a) Do not work in
closed environments or near to naked flames b) Make sure
there is adequate exchange of air at the place of work c)
Protect your nose and mouth with an appropriate mask.
Consult the tool / accessory manual and adhere to any
safety requirements.
- If the electrical cable or plug are damaged, do not use the
compressor and contact an authorised service centre to
replace the faulty element with an original spare part.
- If the compressor is located on a shelf or on a top above
floor height, it must be secured to prevent it falling while in
operation.
- Do not put objects or your hands inside the protective grilles
to avoid injury to yourself or damaging the compressor.
- Do not use the compressor as a blunt object toward things
or animals, to avoid serious damage.
- When you have finished using the compressor, always
remove the plug from the power socket.
ELECTRO-COMPRESSOR MODELS
For the European market, the compressor tanks are
manufactured to meet Directive 2009/105/EC For the
European market, the compressors are manufactured to meet
Directive 2006/42/EC.
For the European market, the compressors are manufactured
to meet Directive 2000/14/EC.
Acoustic pressure measured free-field at a distance of 4m at
maximum operating pressure.
HINTS FOR EFFICIENT OPERATION
- For efficient operation of the machine at full continuing
load and at maximum operating pressure, make sure the
temperature of the work environment indoors does not
exceed +25°C.
THESE COMPRESSORS HAVE BEEN DESIGNED FOR
INTERMITTENT USE. THEY SHOULD ONLY BE USED FOR
APPLICATIONS WHERE USAGE WILL NOT EXCEED 25% OF
DUTY OVER THE COURSE OF ONE HOUR.
STORING THE PACKED AND UNPACKED
COMPRESSOR
For the whole time that the compressor is not used before
unpacking it, store it in a dry place at a temperature between
+5°C and + 45°C and sheltered away from weather. For the
whole time that the compressor is not used after unpacking
it, disconnect from the mains supply, drain the air tank place
sheets over it to protect it from dust, which may settle on the
components. The oil is to be replaced and the operational
efficiency of the compressor is to be checked if it is not used
for long periods.
PNEUMATIC CONNECTIONS
Make sure you always use pneumatic tubes for compressed
air with maximum pressure characteristics that are adequate
for the compressor. Do not attempt to repair tubes if faulty.
WE RESERVE THE RIGHT TO MAKE ANY MODIFICATIONS
WITHOUT PRIOR NOTICE WHENEVER NECESSARY.
ENGLISH
14
TROUBLESHOOTING GUIDE
This section provides a list of the more frequently encountered malfunctions, their causes and corrective actions. The operator
or maintenance personnel can perform some corrective actions, and others may require the assistance of a qualified DeWALT
technician or your dealer.
Problem Code
Excessive air tank pressure-safety valve pops off 1,2
Air leaks 3
Air leaks in air tank or at air tank welds 4
Air leaks between head and valve plate 5
Air leaks from safety valve 6
Knocking Noise 6,16,17
Pressure reading on the regulated pressure gauge drops when an accessory is used 7
Compressor is not supplying enough air to operate accessories 8,9,10,11,12,15
Regulator knob has continuous air leak 13
Regulator will not shut off air outlet 13
Moisture in pump crankcase 14,18
Motor will not run 11,19,20,21,22,
23,24,25,26
CODE POSSIBLE CAUSE POSSIBLE SOLUTION
1Pressure switch does not shut off motor
when compressor reaches cut-out pres-
sure
Set the On/Off switch to OFF, if the unit does not shut off
contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
2Pressure switch cut-out too high Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
3Tube fittings are not tight enough Tighten fittings where air can be heard escaping. Check fittings
with soapy water solution. Do Not Overtighten.
4Defective air tank Air tank must be replaced. Do not repair the leak.
m WARNING: Risk of bursting. Do not drill into, weld or otherwise
modify air tank or it will weaken. The air tank can rupture or
explode.
5Leaking seals Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
6Defective safety valve Operate safety valve manually by pulling on ring. If valve still
leaks, it must be replaced.
7Regulator is not adjusted correctly for
accessory being used
It is normal for some pressure drop to occur when an accessory
is used, adjust the regulator as instructed in Regulator under
Features if pressure drop is excessive.
NOTE: Adjust the regulated pressure under flow conditions while
accessory is being used.
8Prolonged excessive use of air Decrease amount of air usage.
9Compressor is not large enough for
accessory
Check the accessory air requirement. If it is higher than the
CFM or pressure supplied by your air compressor, a larger
compressor is needed to operate accessory.
ENGLISH
15
CODE POSSIBLE CAUSE POSSIBLE SOLUTION
10 Hole in air hose Replace air hose.
11 Check valve restricted Remove, clean or replace.
12 Air leaks Tighten fittings.
13 Regulator is damaged Replace.
14 Unit operating in damp or humid
conditions Move unit to a dry well ventilated area
15 Restricted air intake filter Clean or replace air intake filter
16 Engine or pump oil is low Add same type of oil in crankcase to pump. See Compressor Pump
Oil under Maintenance.
17 Carbon build-up in pump. Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
18 Detergent type oil being used in pump Drain oil and refill pump using DeWALT synthetic or SAE
40, non-detergent air compressor oil.
19 Motor overload protection switch has
tripped See Motor Overload under Features.
20 Extension cord is wrong length or gauge Check for proper gauge wire and cord length. See Extension
Cords under Installation.
21 Loose electrical connections Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
22 Possible defective motor or starting
capacitor
Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
23 Paint spray on internal motor parts
Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center. Do not operate the compressor in the paint spray
area. See flammable vapor warning.
24 Fuse blown, circuit breaker tripped
1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use a fuse or circuit breaker
with higher rating than that specified for your particular
branch circuit.
2. Check for proper fuse. Use only a time delay fuse.
3. Check for low voltage conditions and/or proper extension
cord.
4. Disconnect the other electrical appliances from circuit or
operate the compressor on its own branch circuit.
25 Tank pressure exceeds pressure switch
cut-in pressure
Motor will start automatically when tank pressure drops below
cut-in pressure of pressure switch.
26 Pressure release valve on pressure switch
has not unloaded head pressure
Set the On/Off switch to OFF. If the valve does not open, replace
switch. Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
ENGLISH
16
CLEANING
m WARNING: Blow dirt and dust out of the main housing with
dry air as often as dirt is seen collecting in and around the air
vents. Wear eye protection when performing this procedure.
m WARNING: Never use solvents or other harsh chemicals
for cleaning the non-metallic parts of the tool. These
chemicals may weaken the materials used in these parts.
Use a cloth dampened only with water and mild soap. Never
let any liquid get inside the tool; never immerse
OPTIONAL ACCESSORIES
m WARNING: Since accessories, other than those offered by
DeWALT, have not been tested with this product, use of such
accessories with this tool could be hazardous. To reduce the
risk of injury, only DeWALT recommended accessories should
be used with this product.
PROTECTING THE ENVIRONMENT
Separate collection. This product must not be
disposed of with normal household waste.
Should you find one day that your DeWALT
product needs replacement, or if it is of no further use to
you, do not dispose of it with household waste. Make this
product available for separate collection.
Separate collection of used products and
packaging allows materials to be recycled and
used again. Re-use of recycled materials helps
prevent environmental pollution and reduces the demand
for raw materials.
Local regulations may provide for separate collection of
electrical products from the household, at municipal waste
sites or by the retailer when you purchase a new product.
DeWALT provides a facility for the collection and recycling
of DeWALT products once they have reached the end of
their working life. To take advantage of this service please
return your product to any authorised repair agent who
will collect them on our behalf.
You can check the location of your nearest authorised
repair agent by contacting your local DeWALT office at
the address indicated in this manual. Alternatively, a list
of authorised DeWALT repair agents and full details of
our after-sales service and contacts are available on the
Internet at: www.2helpU.com.
Model DPC6MRC-GB
DPC6MRC-QS
DPC10RC-GB
DPC10RC-QS DPC10RC-LX DPC16PS-GB
DPC16PS-QS DPC16PS-LX
Tank Size (l) 6 10 10 16 16
Volts (ac V) 230 230 110 230 110
Powerpeak Horse power / kW 1,5 / 1,1 2,0 / 1,5 2,0 / 1,5 2,5 / 1,8 2,5 / 1,8
Powerrunning Horse power / kW 1,5 / 1,1 1,85 / 1,4 1,85 / 1,4 2,3 / 1,7 2,3 / 1,7
Current (A) 5 6 13.5 8 14
Pump Type Oil-Free Oil-Free Oil-Free Oil Lubricated Oil Lubricated
Noise / measurement uncertainty, LWA / KWA 97 / 1,5 97 / 1,5 97 / 1,5 91 / 1,5 91 / 1,5
Noise / measurement uncertainty, LPA / KPA 77 77 77 71 71
Maximum Working Presure (bar / psi) 8 / 116 10 / 145 10 / 145 10 / 145 10 / 145
Air Displacement (l/min / cfm) 170 / 6,0 216 / 7,6 216 / 7,6 240 /8,4 208 / 7,3
Air Delivery (l/min / cfm) @ 7 bar) 75 82 82 150 115
Compressor speed in 1/min ( rpm) 3400 3400 3400 2850 2850
Weight (kg) 10.5 18 18 36 36
Protection type
IP20 IP20 IP20 IP20 IP20
FRANÇAIS
17
Lire le manuel d’utilisation :
Avant de positionner, de mettre en service ou de régler le
compresseur, lire attentivement le manuel d’utilisation.
SYMBOLES FIGURANT SUR L'APPAREIL
On trouve les pictogrammes suivants sur l'appareil :
RISQUE DE CHOC ÉLECTRIQUE :
Avertissement : avant d’effectuer toute intervention sur
le compresseur, il est obligatoire de débrancher la source
d’alimentation électrique de la machine.
RISQUE DE TEMPÉRATURES ÉLEVÉES :
Avertissement : certaines pièces du compresseur peuvent
atteindre des températures élevées.
RISQUE DE MISE EN MARCHE ACCIDENTELLE :
Attention : le compresseur peut redémarrer
automatiquement en cas de coupure de courant suivie
d’un rétablissement de la tension.
PORTER UN DISPOSITIF DE PROTECTION AUDITIVE
INFORMATIONS IMPORTANTES
Lire et comprendre toutes les instructions de
fonctionnement, les consignes de sécurité et les mises
en garde contenues dans ce manuel d’utilisation avant
de faire fonctionner le compresseur ou de procéder à
son entretien. La majorité des accidents résultant de
l’utilisation ou de l’entretien du compresseur sont dus
au non respect des consignes et règles de sécurité
élémentaires. En identifiant à temps les situations
potentiellement dangereuses et en respectant les
consignes de sécurité appropriées, les accidents peuvent
souvent être évités. Les consignes élémentaires de
sécurité sont décrites dans la section « SÉCURITÉ » de
ce manuel ainsi que dans les sections renfermant les
instructions d’utilisation et d’entretien. Les dangers
qui doivent être évités afin de prévenir toute blessure
corporelle ou tout dommage sur la machine sont indiqués
par « ATTENTION » sur le compresseur et dans ce manuel.
Utiliser le compresseur DeWALT uniquement aux fins
pour lesquelles il a été conçu, à savoir : appareils
pneumatiques de clouage, appareils de peinture par
pulvérisation, accessoires de gonflage pour pneus, etc.
Veuillez vous assurer que la valeur de pression d'air de
l'appareil que vous raccordez est appropriée.
SIGNIFICATION DU VOCABULAIRE
DE SIGNALISATION
m ATTENTION : indique une situation potentiellement
dangereuse qui, si on ne tient pas compte de son caractère,
risque de provoquer de graves blessures.
m AVERTISSEMENT : indique une situation dangereuse qui, si
on ne tient pas compte de son caractère, risque deprovoquer des
blessures légères ou d’endommager la machine.
REMARQUE : souligne une information essentielle
Consignes de sécurité
CONSIGNES DE SÉCURITÉ IMPORTANTES POUR
L’UTILISATION DU COMPRESSEUR
m ATTENTION : UNE UTILISATION INCORRECTE DU
COMPRESSEUR OU LE NON RESPECT DES CONSIGNES DE
SÉCURITÉ PEUT ENTRAÎNER LA MORT OU DES BLESSURES
GRAVES. AFIN D’ÉVITER TOUT DANGER, RESPECTER CES
CONSIGNES DE SÉCURITÉ ÉLÉMENTAIRES.
BIEN LIRE TOUTES LES INSTRUCTIONS
1. NE JAMAIS TOUCHER AUX PIÈCES MOBILES Ne jamais
approcher les mains, les doigts ou aucune autre partie du
corps des pièces mobiles du compresseur.
2. NE JAMAIS FAIRE FONCTIONNER LE COMPRESSEUR SI
TOUS LES CARTERS DE PROTECTION NE SONT PAS EN
PLACE Ne jamais faire fonctionner le compresseur si tous les
carters de protection ou les dispositifs de sécurité ne sont pas
en place et en bon état. Si une opération d’entretien ou de
réparation nécessite le démontage d’un carter de protection
ou d’un dispositif de sécurité, s’assurer de bien le remonter
avant de remettre le compresseur en marche.
3. TOUJOURS SE PROTÉGER LES YEUX Toujours porter des
lunettes ou un masque de protection oculaire. Ne jamais diriger
le jet d’air comprimé sur une personne ou une partie du corps.
4. SE PROTÉGER CONTRE LES CHOCS ÉLECTRIQUES
Empêcher tout contact du corps avec les surfaces mises à la
terre, par exemple les tuyaux, radiateurs, plaques chauffantes
et enceintes de réfrigération. Ne jamais faire fonctionner le
compresseur dans un endroit humide ou sur une surface
mouillée.
5. DÉBRANCHER LE COMPRESSEUR Toujours débrancher le
compresseur de la source d’alimentation électrique et
évacuer l’air comprimé du réservoir avant toute opération de
révision, d’inspection, d’entretien, de nettoyage, de
remplacement ou de vérification des pièces.
6. ÉVITER TOUTE MISE EN MARCHE ACCIDENTELLE Ne
pas transporter le compresseur lorsqu’il est encore raccordé
à sa source d’alimentation électrique ou lorsque le réservoir
d’air comprimé est plein. Bien s’assurer que le bouton du
pressostat se trouve sur la position « OFF » (arrêt) avant de
raccorder le compresseur à son alimentation.
7. ENTREPOSER CORRECTEMENT LE COMPRESSEUR
Lorsqu’il n’est pas utilisé, le compresseur doit être entreposé
dans un endroit sec. Veiller à ce qu’il soit hors de portée des
enfants. Fermer à clé le local d’entreposage.
8. MAINTENIR L’ESPACE DE TRAVAIL PROPRE Un espace
de travail encombré augmente les risques d’accidents. Le
débarrasser des outils inutiles, débris, meubles, etc.
9. ÉLOIGNER LES ENFANTS Ne pas laisser les visiteurs
toucher à la rallonge du compresseur. Tous les visiteurs
devront se tenir suffisamment éloignés de l’espace de travail.
FRANÇAIS
18
10. SE VÊTIR CORRECTEMENT Ne porter ni vêtements
amples ni bijoux. Ils pourraient se prendre dans les pièces
mobiles. Porter une coiffe de protection pour maintenir les
cheveux longs.
11. FAIRE ATTENTION AU CORDON Ne jamais tirer
brusquement sur le cordon pour le débrancher. Tenir le
cordon à l’écart des sources de chaleur, de graisse et des
surfaces tranchantes.
12. ENTRETENIR LE COMPRESSEUR AVEC SOIN Suivre
les instructions de lubrification. Inspecter régulièrement
les cordons et, s’ils sont endommagés, les faire réparer
dans un centre de service après-vente agréé. Inspecter
périodiquement les rallonges et les faire réparer si elles sont
endommagées.
13. RALLONGES POUR UTILISATION EN EXTÉRIEUR Si
l’outil doit être utilisé en extérieur, utiliser uniquement des
rallonges conçues à cet effet et identifiées comme telles.
14. RESTER SUR SES GARDES Bien faire attention à ce
que l’on fait. Faire preuve de bon sens. Ne pas utiliser
le compresseur en cas de fatigue. Ne jamais utiliser le
compresseur sous l’effet de l’alcool, de drogues ou de
médicaments provoquant la somnolence.
15. VÉRIFIER L’ABSENCE DE PIÈCES ENDOMMAGÉES ET
DE FUITES D’AIR Avant de continuer à utiliser le compresseur,
vérifier attentivement que les carters de protection ou d’autres
pièces ne sont pas endommagés pour s’assurer que le
compresseur pourra fonctionner correctement et effectuer
le travail pour lequel il est conçu. Vérifier l’alignement et le
couplage des pièces mobiles, l’éventuelle présence de pièces
cassées, le support, les fuites d’air et tout autre élément
susceptible d’altérer le bon fonctionnement. Tout carter de
protection ou autre pièce endommagé doit être correctement
réparé ou remplacé par un centre de service après-vente
agréé sauf en cas d’indication contraire dans ce manuel. Les
pressostats défectueux doivent également être remplacés
par un centre de service après-vente agréé. Ne pas utiliser le
compresseur si l’interrupteur ne peut pas être mis en position
« On » ou « Off ».
16. UTILISER LE COMPRESSEUR UNIQUEMENT POUR
LES APPLICATIONS SPÉCIFIÉES DANS LE MANUEL
D’UTILISATION Ne jamais utiliser le compresseur pour des
utilisations autres que celles spécifiées dans le manuel.
Ne jamais utiliser l’air comprimé pour respirer. Ne jamais
marcher ou se tenir debout sur le compresseur.
17. MANIPULER LE COMPRESSEUR CORRECTEMENT Faire
fonctionner le compresseur conformément aux instructions
de ce manuel. Ne jamais laisser les enfants, les personnes
non familiarisées avec son fonctionnement ou toute personne
non autorisée utiliser le compresseur.
18. VÉRIFIER QUE TOUS LES BOULONS, VIS ET
COUVERCLES SONT SOLIDEMENT FIXÉS Veiller à ce que
tous les boulons, vis et plaques soient solidement fixés. Les
vérifier périodiquement.
19. MAINTENIR LA GRILLE D’AÉRATION DU MOTEUR
PROPRE La grille d’aération du moteur doit rester propre en
permanence de façon à ce que l’air puisse circuler librement.
Contrôler fréquemment l’accumulation de poussière.
20. FAIRE FONCTIONNER LE COMPRESSEUR À LA TENSION
ASSIGNÉE Faire fonctionner le compresseur à la tension
spécifiée sur la plaque signalétique. Si le compresseur est
utilisé à une tension supérieure à la tension assignée, il en
résultera une vitesse de rotation du moteur anormalement
élevée risquant d’endommager le compresseur et de griller
le moteur.
21. NE JAMAIS UTILISER UN COMPRESSEUR DÉFECTUEUX
OU DONT LE FONCTIONNEMENT EST ANORMAL Si le
compresseur semble ne pas fonctionner correctement, s’il
émet un bruit bizarre ou s’il semble défectueux, l’arrêter
immédiatement et le faire réparer dans un centre de service
après-vente agréé.
22. NE PAS NETTOYER LES PIÈCES EN PLASTIQUE AVEC
DU SOLVANT Les solvants tels que l’essence, les diluants,
la benzine, le tétrachlorure de carbone et l’alcool risquent
d’endommager et de fendre les pièces en plastique. Ne
pas les nettoyer avec ce genre de produits. Pour nettoyer
les pièces en plastique, utiliser un chiffon doux légèrement
imbibé d’eau savonneuse puis sécher complètement.
23. UTILISER UNIQUEMENT DES PIÈCES DE RECHANGE
D’ORIGINE L’utilisation de pièces de rechange autres que
celles d’origine peut entraîner l’annulation de la garantie et
être la cause d’un mauvais fonctionnement et des blessures
en résultant. Les pièces d’origine sont disponibles auprès de
votre distributeur.
24. NE PAS MODIFIER LE COMPRESSEUR Ne pas
modifier le compresseur. Toujours consulter un centre
de service après-vente agréé pour toute réparation. Une
modification non autorisée risque non seulement d’affecter
les performances du compresseur, mais également d’être
la cause d’accidents et de blessures pour le personnel
de réparation qui ne posséderait pas les compétences
techniques nécessaires pour le réparer correctement.
25. DÉSACTIVER LE PRESSOSTAT LORSQUE LE
COMPRESSEUR N’EST PAS UTILISÉ Lorsque le compresseur
n’est pas en fonctionnement, régler le bouton du pressostat
sur « OFF », débrancher le compresseur et ouvrir le robinet de
vidange pour vider le réservoir d’air comprimé.
26. NE JAMAIS TOUCHER LES SURFACES CHAUDES Pour
éviter tout risque de brûlures, ne pas toucher les tuyaux, les
têtes, les cylindres et les moteurs.
27. NE PAS DIRIGER LE JET D’AIR DIRECTEMENT SUR LE
CORPS Sous peine de blessures, ne pas diriger le jet d’air sur
des personnes ou des animaux.
28. VIDANGER LE RÉSERVOIR Vidanger le réservoir tous les
jours ou toutes les 4 heures d’utilisation. Ouvrir le bouchon de
vidange et incliner le compresseur pour vider l’eau qui s’est
accumulée.
FRANÇAIS
19
29. NE PAS ARRÊTER LE COMPRESSEUR EN TIRANT SUR
LA PRISE Utiliser le bouton « AUTO/OFF » du pressostat.
30. POUR LE CIRCUIT PNEUMATIQUE, N’UTILISER QUE
DES PIÈCES RECOMMANDÉES SUPPORTANT UNE
PRESSION SUPÉRIEURE OU ÉGALE À 125PSI (8,6 BARS)
Il y a risque d’explosion. N’utiliser que des pièces pour
circuit pneumatique recommandées supportant une pression
supérieure ou égale à 125 psi (8,6 bars).
31. EINEN GEEIGNETEN HÖR- UND KOPFSCHUTZ
TRAGEN Bei der Bedienung des Kompressors und
des angeschlossenen Werkzeugs oder Zubehörs muss
eine geeignete Schutzkleidung getragen werden. Die
Bedienungsanleitung des Werkzeugs/Zubehörs ist stets zu
beachten und sämtliche Sicherheitshinweise zu befolgen.
32. PRENDRE EN COMPTE LES ASPECTS
ENVIRONNEMENTAUX
Ne pas exposer le compresseur à la pluie. Ne jamais utiliser
le compresseur dans des conditions humides ou mouillées.
Assurer de bonnes conditions d'éclairage. Ne jamais utiliser le
compresseur à proximité de liquides ou de gaz inflammables.
PIECES DE RECHANGE
Pour les réparations, utiliser uniquement des pièces de
rechange identiques aux pièces remplacées. Confier toute
réparation à un centre de service après-vente agréé.
RALLONGE
Utiliser uniquement des rallonges à trois conducteurs possédant
des fiches à trois broches avec terre et des prises tripolaires
adaptées à la prise du compresseur. Remplacer ou réparer
la rallonge endommagée. Vérifier que la rallonge est en bon
état. Lors de l’utilisation d’une rallonge, s’assurer d’en utiliser
une suffisamment résistante pour supporter le courant que
votre produit laissera passer. Une rallonge trop faible peut
provoquer des chutes de tension et, par conséquent, une perte
de puissance ainsi qu’une surchauffe de l’appareil. Le tableau
indique la taille à utiliser en fonction de la longueur de la rallonge
et du nombre d’ampères indiqué sur la plaque signalétique. En
cas de doute, utiliser le calibre supérieur suivant. Plus le numéro
de calibre est petit, plus la rallonge est puissante.
Lors de l'utilisation d'un outil électrique en extérieur, utiliser
une rallonge spécialement conçue à cet effet. L'utilisation
d'une rallonge adaptée à une utilisation en extérieur réduit les
risques de décharges électriques.
SECTION VALABLE POUR UNE LONGUEUR
MAXIMALE DE 20 MT MONOPHASÉ
Puissance / Puissance / 220/230V 110/120V
HP kW mm2 mm2
0,75-1 0,65-0,7 1,5 2,5
1,5 1,1 2,5 4
2 1,5 2,5 4-6
2,5-3 1,8-2,2 4 -
m ATTENTION Éviter tous les risques de chocs électriques.
Ne jamais utiliser le compresseur avec une rallonge ou un
câble électrique endommagé. Contrôler régulièrement les
câbles électriques. Ne jamais utiliser le compresseur dans
l’eau ou à proximité de celle-ci ainsi qu’à proximité d’un lieu
où il y a risque de choc électrique.
VANNE DE SURETE
Ce compresseur est muni d'une vanne de sûreté qui est
prévue pour éviter toute surpressurisation des réservoirs
d'air. Cette vanne est réglée en usine et ne fonctionnera pas
à moins que la pression du réservoir n'atteigne ce niveau de
pression.
m MISE EN GARDE : NE PAS ESSAYER DE REGLER OU DE
SUPPRIMER CE DISPOSITIF DE SECURITE. TOUT REGLAGE
DE CETTE VANNE SERAIT SUSCEPTIBLE DE CAUSER DES
BLESSURES GRAVES. Si cet appareil a besoin d’entretien ou de
réparation, s’adresser à un Centre d’entretien agréé DeWALT.
Attachements et accessoires :
Pour chaque attachement ou accessoire que vous utiliserez
avec ce compresseur, la pression maximum permise
conseillée devrait figurer clairement sur le produit ou sur
son mode d’emploi. Excéder les niveaux de pression de
ces attachements (y compris, mais non limité à : outils
pneumatiques, accessoires fonctionnant avec de l’air,
pistolets de projection, conduits d’air, raccords de conduits
d’air, pneus et autres objets gonflables) pourrait entraîner leur
éclatement et leur explosion et causer des blessures graves.
Ne jamais dépasser la pression maximum conseillée par
le fabricant de tout attachement ou accessoire que vous
utilisez avec ce compresseur.
CAPACITE DE FONCTIONNEMENT :
Pour assurer que ce compresseur d’air DeWALT fonctionne
pendant longtemps, ne pas l’utiliser à plus de la capacité
maximum indiquée sur la plaquette de données techniques.
Si, par exemple, ce compresseur fonctionne pendant plus de
25% d’une heure, sa capacité à fournir de l’air sera moindre
que la quantité nécessaire à l’application.
Toujours faire correspondre les exigences de volume d’air de
l’attachement ou de l’accessoire utilisé avec le volume d’air
que le compresseur est capable de fournir.
Pour éviter une surchauffe du moteur électrique, ce
compresseur est conçu pour une utilisation discontinue comme
indiqué sur la plaque de données techniques (par exemple,
S3-25 signifie 2.5 minutes ALLUME, 7.5 minutes ETEINT).
CONSERVER CES INSTRUCTIONS ET LES
METTRE À DISPOSITION DES PERSONNES
QUI UTILISENT CET APPAREIL
FRANÇAIS
20
UTILISATION ET ENTRETIEN
REMARQUE : les informations contenues dans ce manuel
d’utilisation ont pour objectif d’assister l’opérateur durant
l’utilisation et les opérations d’entretien du compresseur en
toute sécurité. Certaines illustrations de ce manuel peuvent
montrer des détails ou des accessoires qui différent de ceux
de votre compresseur.
INSTALLATION
Après avoir déballé le compresseur, vérifier qu’il est en bon
état en contrôlant qu’il n’a pas subi de dommages durant le
transport puis effectuer les opérations suivantes :
DPC16PS UNIQUEMENT
m Mise en garde : risque de blessures corporelles.
Ne pas placer les mains entre la poignée et le panneau
supérieur lors du montage pour éviter de se pincer.
1. Placer la poignée (5) dans les douilles du panneau
supérieur (7).
2. Enfoncer les boutons pression et glisser la poignée à
travers les premières douilles jusqu'à ce qu'elle s'arrête au
niveau des deuxièmes douilles.
3. En dessous du panneau supérieur, enfoncer à nouveau les
boutons pression et glisser pour atteindre les deuxièmes
douilles.
4. Tirer à fond sur la poignée jusqu'à ce qu'elle s'arrête.
Tourner les boutons de verrouillage (15) pour verrouiller
la poignée. IMPORTANT : toujours soulever la poignée et
verrouiller avant de l'utiliser comme diabolo.
5. Lorsque la fonction de diabolo n'est pas utilisée, dévisser
les boutons de verrouillage et pousser la poignée vers le
bas jusqu'à ce qu'elle s'arrête.
LUBRIFICATION ET HUILE - DPC16PS UNIQUEMENT
m MISE EN GARDE : le compresseur a été expédié avec de
l’huile dans le carter. Veuillez vérifier attentivement que le
niveau d’huile soit correct.
Ne pas tenter de faire fonctionner ce compresseur d'air sans
avoir auparavant ajouté de l'huile dans le carter. De sérieux
dommages pourraient être causés par un fonctionnement,
même limité, en l'absence d'huile dans la pompe et sans
aucun rodage. Respecter à la lettre les directives du Réglage
initial sous fonctionnement.
m Mise en garde : ne pas utiliser les huiles de moteurs
automobiles, par exemple 10W-30, car leur viscosité n'est
pas adéquate. Elles laissent des dépôts de carbone dans des
composants essentiels, réduisant ainsi les performances et la
durée de vie du compresseur. Utiliser de l'huile non-détergente
de synthèse DeWALT ou SAE 40 pour compresseur d'air.
1. Déposer l'appareil sur une surface à niveau.
2. Retirer la jauge d'huile (13) et vérifier le niveau d’huile. Ajouter
progressivement de l'huile non-détergente de synthèse
DeWALT ou SAE 40 pour compresseur d'air si nécessaire.
REMARQUE : consulter les spécifications pour la capacité de
l'huile de la pompe.
m Mise en garde : risque d'utilisation dangereuse. Un réservoir
trop plein d'huile provoquera une défaillance prématurée du
compresseur. Ne pas remplir plus que nécessaire.
3. Repositionner la jauge.
REMARQUE : certains appareils (DPC6MRC, DPC10RC)
sont munis d’une pompe sans huile. Il n’y a aucune huile
à remplacer ni à vérifier.
BRANCHEMENT ÉLECTRIQUE
Ne pas utiliser le cordon de façon abusive. Ne jamais
utiliser le cordon pour transporter, tirer ou débrancher
un outil électrique. Protéger le cordon de toute source
de chaleur, de l’huile, et de tout bord tranchant ou pièce
mobile.
Les cordons endommagés ou emmêlés augmentent les
risques de décharges électriques.
Les compresseurs monophasés sont fournis avec un câble
électrique et une fiche bipolaire avec terre. Il est important
que le compresseur soit branché à une prise de terre (fig. 4).
IMPORTANT : ne jamais utiliser la prise de terre à la
place du fil neutre. Le branchement à la terre doit être
effectué selon les normes de sécurité (EN 60204). La fiche
du câble d’alimentation ne doit pas être utilisée comme
interrupteur mais doit être introduite dans une prise de
courant commandée par un interrupteur différentiel approprié
(magnétothermique).
m DANGER : RISQUE DE CHOC ELECTRIQUE. UNE MISE
À LA TERRE INADÉQUATE PEUT PROVOQUER UN CHOC
ÉLECTRIQUE.
Do not modify the plug provided. If it does not fit the available
outlet, a correct outlet should be installed by a qualified
electrician.
Repairs to the cord set or plug MUST be made by a qualified
electrician.
MODE D'EMPLOI
LISTE DE VERIFICATION DE PRE-DEMARRAGE
1. S’assurer que le commutateur Marche/Arrêt (6) est en
position d'Arrêt.
2. Brancher le cordon d’alimentation dans le bon réceptacle
de circuit de dérivation. Consulter la rubrique Branchement
électrique (ci-dessus).
3. S’assurer que le réservoir d’air soit bien purgé, consulter la
rubrique Vidange du réservoir d’air sous entretien.
4. S’assurer que la vanne de purge (2) soit fermée.
5. S’assurer que la vanne de sûreté (14) fonctionne
correctement, consulter la rubrique Vérification de la vanne
de sûreté sous entretien.
6. Vérifier le niveau d’huile de la pompe, consulter la rubrique
Huile de la pompe du compresseur sous entretien.
(DPC16PS uniquement)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200

DeWalt DPC16PS Manuel utilisateur

Catégorie
Compresseurs d'air
Taper
Manuel utilisateur
Ce manuel convient également à

Autres documents