DeWalt D55153 Manuel utilisateur

Catégorie
Compresseurs d'air
Taper
Manuel utilisateur
D55151, D55152, D55153, D55155
Contractors Electric 4 Gallon Hand Carry Air Compressor
Compresseurs d’air portatifs électriques de 4 gallons de classe entrepreneur
Compresor de aire portátil elèctrico de 4 galones para contratistas
INSTRUCTION MANUAL
GUIDE D'UTILISATION
MANUAL DE INSTRUCCIONES
INSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO Y PÓLIZA
DE GARANTÍA. ADVERTENCIA: LÉASE ESTE INSTRUCTIVO ANTES
DE USAR EL PRODUCTO.
If you have questions or comments, contact us.
Pour toute question ou tout commentaire, nous contacter.
Si tiene dudas o comentarios, contáctenos.
1-800-4-DeWALT • www.dewalt.com
2
English
A. On/Off Switch
B. Air Tank Pressure Gauge
C. Regulated Pressure Gauge
D. Pressure Regulator
E. Quick Connects (if equipped)
F. Check Valve
G. Safety Valve
H. Air Tank Drain Valve
I. Power Cord Wrap
J. Pressure Switch
K. Pump Oil Dipstick
L. Pump Oil Drain Plug
M. Motor Reset
N. Air Intake Filter
Air Compressor
C
NOT A
STEP
D
B
E
K
L
J
D
E
L
M
I
F
B
C
A
G
A
H
K
F
M
N
N
J
G
FIG. 1
3
English
Specications
MODEL
D55151 D55152 D55153 D55155
WEIGHT
56 lbs. (25.4 kg) 65 lbs. (29.5 kg) 58 lbs. (28.3 kg) 61 lbs. (27.7 kg)
HEIGHT
16.75" (425.5 mm) 16.0" (406.4 mm) 16.75" (501.7 mm) 12.5" (317.5 mm)
WIDTH
18.0" (457.2 mm) 18.0" (457.2 mm) 18.0" (457.2 mm) 21.75" (552.5 mm)
LENGTH
15.0 (381 mm) 18.0" (457.2 mm) 15.0 (381 mm) 21.75" (552.5 mm)
AIR TANK CAPACITY (GALLONS)
4.0 (15.1 liters) 4.0 (15.1 liters) 4.0 (15.1 liters) 4.0 (15.1 liters)
APPROX CUT-IN PRESSURE
95 PSI (655 kPa) 95 PSI (655 kPa) 95 PSI (655 kPa) 100 PSI (689.5 kPa)
APPROX. CUT-OUT PRESSURE
125 PSI (861.8 kPa) 125 PSI (861.8 kPa) 125 PSI (861.8 kPa) 125 PSI (861.8 kPa)
SCFM @ 100 PSI (689.5 kPa)
3.2 3.8 3.8 4.5
MOTOR
1.1 HP (continuous) 1.1 HP (continuous) 1.1 HP (continuous) 1.2 HP (continuous)
Volts/Amps/Hertz
120V/12.5 A/60 Hz. 120V/14 A/60 Hz. 120V/14 A/60 Hz. 120V/15 A/60 Hz.
RPM
3450 3450 3450 3450
Minumum Branch Circuit
Requirement
15 Amp 15 Amp 15 Amp 15 Amp
PUMP OIL CAPACITY
6 oz. (177.4 ml) 12 oz. (354.9 ml) 12 oz. (354.9 ml) 4 oz. (118.3 ml)
DUTY CYCLE
5 MINUTES ON / 5
MINUTES OFF
5 MINUTES ON / 5
MINUTES OFF
5 MINUTES ON / 5
MINUTES OFF
5 MINUTES ON / 5
MINUTES OFF
4
English
Denitions: Safety Guidelines
The definitions below describe the level of severity
for each signal word. Please read the manual and
pay attention to these symbols.
DANGER: Indicates an imminently hazardous
situation which, if not avoided, will result in death
or serious injury.
WARNING: Indicates a potentially hazardous
situation which, if not avoided, could result in death
or serious injury.
CAUTION: Indicates a potentially hazardous
situation which, if not avoided, may result in minor or
moderate injury.
CAUTION: Used without the safety alert symbol
indicates a potentially hazardous situation which, if
not avoided, may result in property damage.
PUMP
CYLNDER
AND HEAD
Hot Surfaces
FIG. 2
OUTLET TUBE
CHECK
VALVE
CHECK
VALVE
OUTLET TUBE
IF YOU HAVE ANY QUESTIONS OR COMMENTS ABOUT
THIS OR ANY D
e
WALT TOOL, CALL US TOLL FREE AT:
1-800-4-D
e
WALT (1-800-433-9258)
Important Safety Instructions
WARNING: Do not operate this unit until you read and understand
this instruction manual for safety, operation and maintenance
instructions.
WARNING: Some dust created by power sanding, sawing, grind-
ing, drilling, and other construction activities contains chemicals
known to the State of California to cause cancer, birth defects or other
reproductive harm. Some example of these chemicals are:
• leadfromlead-basedpaints
• crystalline silica from bricks and cement and other masonry
products
• arsenicandchromiumfromchemically-treatedlumber
Your risk from these exposures varies, depending on how often
you do this type of work. To reduce your exposure to these
chemicals: work in a well ventilated area, and work with approved
safety equipment, al ways wear OSHA/MSHA/NIOSH approved,
properly t ting face mask or res pi ra tor when us ing such tools.
When using air tools, basic safety precautions should always be
followed to reduce the risk of of personal injury.
WARNING: This product contains chemicals, including lead,
known to the State of California to cause cancer, and birth
defects or other reproductive harm. Wash hands after handling.
5
English
SAVE THESE INSTRUCTION
DANGER: RISK OF EXPLOSION OR FIRE
WHAT CAN HAPPEN HOW TO PREVENT IT
• Itisnormalforelectrical
contacts within the motor
and pressure switch to
spark.
• Alwaysoperatethecom-
pressor in a well ventilated
area free of combustible
materials, gasoline, or sol-
vent vapors.
• Ifelectricalsparksfrom
compressor come into
contact with flammable
vapors, they may ignite,
causing fire or explosion.
• Ifsprayingflammablemate-
rials, locate compressor at
least 20 feet (6.1 m) away
from spray area. An addi-
tional length of hose may be
required.
• Storeflammablematerialsin
a secure location away from
compressor.
• Restrictinganyofthe
compressor ventilation
openings will cause seri-
ous overheating and could
cause fire.
• Neverplaceobjectsagainst
or on top of compressor.
• Operatecompressorin
an open area at least 12"
(30.5 cm) away from any
wall or obstruction that
would restrict the flow of
fresh air to the ventilation
openings.
• Operatecompressorina
clean, dry well ventilated
area. Do not operate unit
indoors or in any confined
area.
• Unattendedoperationof
this product could result in
personalinjuryorproperty
damage. To reduce the
risk of fire, do not allow
the compressor to operate
unattended.
• Always remain in atten-
dance with the product
when it is operating.
• Always turn off and unplug
unit when not in use.
6
English
DANGER: RISK TO BREATHING (ASPHYXIATION)
WHAT CAN HAPPEN HOW TO PREVENT IT
• Thecompressedairdirectly
from your compressor is not
safe for breathing. The air
stream may contain carbon
monoxide, toxic vapors,
or solid particles from the
air tank. Breathing these
contaminant's can cause
seriousinjuryordeath.
• Airobtaineddirectlyfromthe
compressor should never
be used to supply air for
human consumption. In order
to use air produced by this
compressor for breathing,
suitable filters and in-line
safety equipment must be
properly installed. In-line
filters and safety equipment
usedinconjunctionwiththe
compressor must be capable
of treating air to all applicable
local and federal codes prior
to human consumption.
• Sprayedmaterialssuchas
paint, paint solvents, paint
remover, insecticides, weed
killers, may contain harmful
vapors and poisons.
• Workinanareawithgood
cross ventilation. Read and
follow the safety instructions
provided on the label or
safety data sheets for the
materials you are spraying.
Always use certified safety
equipment: OSHA/MSHA/
NIOSH respiratory protection
designed for use with your
specific application.
DANGER: RISK OF INJURY OR PROP ER TY DAMAGE WHEN
TRANSPORTING OR STORING
WHAT CAN HAPPEN HOW TO PREVENT IT
• Oilcanleakorspilland
could result in fire or
breathing hazard; serious
injuryordeathcanresult.Oil
leaks will damage carpet,
paint or other surfaces in
vehicles or trailers.
• Alwaysplacecompressor
on a protective mat when
transporting to protect against
damage to vehicle from leaks.
Remove compressor from
vehicle immediately upon
arrival at your destination.
Always keep compressor level
and never lie on its side.
WARNING: RISK OF BURSTING
Air Tank: The air tank on your Air Compressor is designed and
may be UM coded (for units with air tanks greater than 6 inch
diameter) according to ASME Section VIII, Div. 1 rules. All pressure
vessels should be inspected once every two years. To find your
state pressure vessels inspector, look under the Division of Labor
and Industries in the government section of a phone book or call
1-800-4-DeWALT for assistance.
The following conditions could lead to a weakening of the air tank,
and result in a violent air tank explosion:
7
English
WHAT CAN HAPPEN HOW TO PREVENT IT
• Failuretoproperlydrain
condensed water from
air tank, causing rust and
thinning of the steel air tank.
• Drainairtankdailyorafter
each use. If air tank develops
a leak, replace it immediately
with a new air tank or replace
the entire compressor.
• Modificationsorattempted
repairs to the air tank.
• Neverdrillinto,weld,ormake
any modifications to the
air tank or its attachments.
Never attempt to repair a
damaged or leaking air tank.
Replace with a new air tank.
• Unauthorizedmodifications
to the safety valve or any
other components which
control air tank pressure.
• Theairtankisdesigned
to withstand specific
operating pressures. Never
makeadjustmentsor
parts substitutions to alter
the factory set operating
pressures.
Attachments & accessories:
• Exceedingthepressure
rating of air tools, spray
guns, air operated
accessories, tires, and other
inflatables can cause them
to explode or fly apart, and
couldresultinseriousinjury.
• Followtheequipment
manufacturers
recommendation and never
exceed the maximum
allowable pressure rating
of attachments. Never use
compressor to inflate small
lowpressureobjectssuch
as children’s toys, footballs,
basketballs, etc.
WARNING: RISK OF ELECTRICAL SHOCK
WHAT CAN HAPPEN HOW TO PREVENT IT
• Your air compressor is
powered by electricity.
Like any other electrically
powered device, If it is not
used properly it may cause
electric shock.
• Never operate the
compressor outdoors
when it is raining or in wet
conditions.
• Never operate compressor
with protective covers
removed or damaged.
• Repairs attempted by
unqualified personnel can
resultinseriousinjuryor
death by electrocution.
• Any electrical wiring
or repairs required on
this product should be
performed by a DeWALT
factory service center or a
DeWALT authorized service
center in accordance with
national and local electrical
codes.
• Electrical Grounding:
Failure to provide
adequate grounding to
this product could result
inseriousinjuryordeath
from electrocution. See
Grounding Instructions
under Installation.
• Make certain that the
electrical circuit to which the
compressor is connected
provides proper electrical
grounding, correct voltage
and adequate fuse
protection.
8
English
WARNING: RISK FROM FLYING OBJECTS
WHAT CAN HAPPEN HOW TO PREVENT IT
• Thecompressedair
stream can cause soft
tissue damage to exposed
skin and can propel dirt,
chips, loose particles,
andsmallobjectsathigh
speed, resulting in property
damageorpersonalinjury.
• Always wear certified safety
equipment: ANSI Z87.1 eye
protection (CAN/CSA Z94.3)
with side shields when using
the compressor.
• Neverpointanynozzleor
sprayer toward any part of
the body or at other people
or animals.
• Alwaysturnthecompressor
off and bleed pressure
from the air hose and air
tank before attempting
maintenance, attaching tools
or accessories.
WARNING: RISK OF HOT SURFACES
WHAT CAN HAPPEN HOW TO PREVENT IT
• Touchingexposedmetal
such as the compressor
head, engine head, engine
exhaust or outlet tubes, can
result in serious burns.
• Nevertouchanyexposed
metal parts on compressor
during or immediately after
operation. Compressor
will remain hot for several
minutes after operation.
• Donotreacharound
protective shrouds or
attempt maintenance until
unit has been allowed to
cool.
WARNING: RISK FROM MOVING PARTS
WHAT CAN HAPPEN HOW TO PREVENT IT
• Movingpartssuchasthe
pulley, flywheel, and belt
cancauseseriousinjuryif
they come into contact with
you or your clothing.
• Neveroperatethe
compressor with guards or
covers which are damaged or
removed.
• Keepyourhair,clothing,and
gloves away from moving
parts.Looseclothes,jewelry,
or long hair can be caught in
moving parts.
• Airventsmaycovermoving
parts and should be avoided
as well.
9
English
• Attemptingtooperate
compressor with damaged
or missing parts or
attempting to repair
compressor with protective
shrouds removed can
expose you to moving parts
and can result in serious
injury.
• Anyrepairsrequiredonthis
product should be performed
by a DeWALT factory
service center or a DeWALT
authorized service center.
WARNING: RISK OF UNSAFE OPERATION
WHAT CAN HAPPEN HOW TO PREVENT IT
• Unsafeoperationofyour
air compressor could lead
toseriousinjuryordeathto
you or others.
• Reviewandunderstandall
instructions and warnings in
this manual.
• Becomefamiliarwiththe
op eration and con trols of the
air compressor.
• Keepoperatingareaclear
of all persons, pets, and
obstacles.
• Keepchildrenawayfromthe
air compressor at all times.
• Donotoperatetheproduct
when fatigued or under the
influence of alcohol or drugs.
Stay alert at all times.
• Neverdefeatthesafetyfea
tures of this prod uct.
• Equipareaofoperationwith
a fire extinguisher.
• Donotoperatemachinewith
missing, broken, or un au tho-
rized parts.
WARNING: RISK OF FALLING
WHAT CAN HAPPEN HOW TO PREVENT IT
• Aportablecompressor
can fall from a table,
workbench, or roof
causing damage to the
compressor and could
resultinseriousinjuryor
death to the operator.
• Alwaysoperatecompressor
in a stable secure position
to prevent accidental
movement of the unit.
Never operate compressor
on a roof or other elevated
position. Use additional
air hose to reach high
locations.
CAUTION: RISK FROM NOISE
WHAT CAN HAPPEN HOW TO PREVENT IT
• Under some conditions
and duration of use, noise
from this product may
contribute to hearing loss.
• Alwayswearcertifiedsafety
equipment: ANSI S12.6
(S3.19) hearing protection.
10
English
SAVE THESE INSTRUCTIONS
FOR FUTURE USE
FEATURES (Fig. 1)
ON/OFF SWITCH
Place this switch (A) in the ON position to
G
A
J
provide automatic power to the pres-
sure switch and OFF to remove power
at the end of each use.
PRESSURE SWITCH
The pressure switch (J) automatically
starts the motor when the air tank pres-
sure drops below the factory set cut-in
pressure. It stops the motor when the air tank pressure reaches
the factory set cut-out pressure.
PRESSURE RELEASE VALVE
The pressure release valve located on the side of the pressure
switch, is designed to automatically release compressed air from
the compressor head and the outlet tube when the air compressor
reaches cut-out pressure or is shut off. The pressure release valve
allows the motor to restart freely. When the motor stops running,
air will be heard escaping from this valve for a few seconds. No air
should be heard leaking when the motor is running or after the unit
reaches cut-out pressure.
SAFETY VALVE
If the pressure switch does not shut off the air compressor at its
cut-out pressure setting, the safety valve (G) will protect against
high pressure by popping out at its factory set pressure (slightly
higher than the pressure switch cut-out setting).
CHECK VALVE
When the air compressor is operating, the check
F
valve (F) is open, allowing compressed air to
enter the air tank. When the air compressor
reaches cut-out pressure, the check valve
closes, allowing air pressure to remain inside the
air tank.
TANK PRESSURE GAUGE
The tank pressure gauge (B) indi-
D
C
E
B
cates the reserve air pressure in
the tank.
OUTLET PRESSURE GAUGE
The outlet pressure gauge (C)
indicates the air pressure avail-
able at the outlet side of the
regulator. This pressure is controlled by the regulator and is
always less than or equal to the tank pressure.
REGULATOR
The regulator (D) controls the air pressure shown on the outlet
pressure gauge. Turn regulator knob clockwise to increase
pressure and counterclockwise to decrease pressure.
UNIVERSAL QUICK CONNECT BODIES (IF EQUIPPED)
The universal quick connect body (E) accepts the three most
popular styles of quick connect plugs: Industrial, automotive, and
ARO. One hand push-to-connect operation makes connections
simple and easy. The two quick connect bodies allow the use of
two tools at the same time.
11
English
DRAIN VALVE
The drain valve (H) is located at the base
H
of the air tank and is used to drain con-
densation at the end of each use.
See
Draining Air Tank under Maintenance.
COOLING SYSTEM
This compressor contains an advanced design cooling system.
It is normal for this fan to blow air through the vent holes in large
amounts. The cooling system is working when air is expelled.
AIR COMPRESSOR PUMP
The pump compresses air into the air tank. Working air is not
available until the compressor has raised the air tank pressure
above that required at the air outlet.
MOTOR OVERLOAD PROTECTOR
This motor has a manual thermal overload
K
M
N
protector. If the motor overheats for any
reason, the overload protector will shut off
the motor. The motor must be allowed to
cool down before restarting. To restart:
1. Ensure the On/Off switch (A) is in the
OFF position.
2. Allow the motor to cool.
3. Depress the reset button (M) on the
motor.
OIL DIPSTICK
The oil dipstick (K) indicates the amount of oil in the pump. Check
pump oil daily, see Compressor Pump Oil under Maintenance.
AIR INTAKE FILTER
The filter (N) is designed to clean air entering the pump. To ensure
the pump continually receives a clean, cool, and dry air supply the
filter must always be clean and the filter intake must be free from
obstructions.
INSTALLATION
Assembly
INSTALLING HOSES
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads 0 PSI (0 kPa).
2. Grasp the hose at the quick connect plug and push the plug
into the quick connect body (E). Coupler will snap into place.
3. Grasp the hose and pull to ensure coupler is seated.
DISCONNECTING HOSES
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads 0 PSI (0 kPa).
2. Pull coupler on quick connect body back to release quick
connect plug on hose.
Lubrication and Oil
CAUTION: The compressor was shipped with oil in the crankcase.
A shipping plug is used to prevent oil from leaking during
shipment. Do not attempt to operate this air compressor without
rst checking the oil level. Serious damage can result from even
limited operation unless lled with oil and broken in correctly.
Closely follow Initial Set-up under Operation.
12
English
CAUTION: Multi-viscosity motor oils, like 10W30, should not be
used in an air compressor. They leave carbon deposits on critical
components, thus reducing performance and compressor like.
Use SAE 40, non-detergent air compressor oil only.
1. Place unit on a level surface.
K
2. Remove the shipping plug and install the
dipstick.
3. Remove the dipstick (K) and check the oil
level. Oil should not exceed top raised line on
dipstick. If oil is below lower mark see
Checking Oil under Compressor Pump
Oil under Maintenance. NOTE: See
Specifications for pump oil capacity.
CAUTION: Risk of unsafe operation. Overlling with oil will cause
premature compressor failure. Do not overll.
4. Replace dipstick.
Grounding Instructions
WARNING: Risk of electrical shock. In the event of a short circuit,
grounding reduces the risk of shock by providing an escape wire for
the electric current. This air compressor must be properly grounded.
The portable air compressor is equipped with a cord having a
grounding wire with an appropriate grounding plug.
1. The cord set and plug (O) with this unit
P
O
Q
contains a grounding pin (P). This
plug MUST be used with a grounded
outlet (Q).
IMPORTANT: The outlet being used must
be installed and grounded in accordance
with all local codes and ordinances.
2. Ensure the outlet being used has the same configuration as
the grounded plug. DO NOT USE AN ADAPTER.
3. Inspect the plug and cord before each use. Do not use if there
are signs of damage.
4. If these grounding instructions are not completely understood,
or if in doubt as to whether the compressor is properly
grounded, have the installation checked by a qualified
electrician.
DANGER: Risk of electrical shock. IMPROPER GROUNDING
CAN RESULT IN ELECTRICAL SHOCK.
• Donotmodifytheplugprovided.Ifitdoesnotttheavailableoutlet,
a correct outlet should be installed by a qualied electrician.
• RepairstothecordsetorplugMUSTbemadebyaqualied
electrician.
Extension Cords
Using extension cords is not recommended. The use of extension
cords will cause voltage to drop resulting in power loss to the
motor and overheating.
Instead of using an extension cord, increase the working reach of
the air hose by attaching another length of hose to its end. Attach
additional lengths of hose as needed.
If an extension cord must be used, be sure it is:
• a3wireextensioncordthathasa3bladegroundingplug,and
a 3-slot receptacle that will accept the plug on the product
• ingoodcondition
• nolongerthan50feet(15,2m)
• 12gauge(AWG)orlarger.(Wiresizeincreasesasgaugenum-
ber decreases. 10 AWG and 8 AWG may also be used. DO
NOT USE 14 OR 16 AWG.)
13
English
Voltage and Circuit Protection
Refer to the Voltage and Minimum Branch Circuit Requirements
under Specications.
CAUTION: Certain air compressors can be operated on a
15 amp circuit if the following conditions are met.
• Voltage supply to circuit must comply with the National
Electrical Code.
• Circuitisnotusedtosupplyanyotherelectricalneeds.
• Extensioncordscomplywithspecications.
• Circuitis equipped with a 15amp circuitbreaker or 15amp
time delay fuse. NOTE: If compressor is connected to a circuit
protected by fuses, use only time delay fuses. Time delay fuses
should be marked “D” in Canada and “T” in the US.
If any of the above conditions cannot be met, or if operation of the
compressor repeatedly causes interruption of the power, it may be
necessary to operate it from a 20 amp circuit. It is not necessary
to change the cord set.
Compatibility
Air tools and accessories that are run off the compressor must
be compatible with petroleum-based products. If you suspect
that a material is not compatible with petroleum products, an air
line filter for removal of moisture and oil vapor in compressed air
is required.
NOTE: Always use an air line filter to remove moisture and oil
vapor when spraying paint.
Location
Place the air compressor in a clean, dry and well ventilated area
at least 12" (30.5 cm) away from the wall or other obstructions
that will interfere with the flow of air. Keep the compressor away
from areas that have dirt and/or volatile fumes in the atmosphere.
These impurities may clog the intake filter and valves, causing
inefficient operation.
The air compressor pump and shroud are designed to allow for
proper cooling. The ventilation openings on the compressor are
necessary to maintain proper operating temperature. Do not
place rags or other containers on or near these openings.
Place the air compressor on a flat surface resting on the rubber
feet.
NOISE CONSIDERATIONS
Consult local officials for information regarding acceptable
noise levels in your area. To reduce excessive noise, use
vibration mounts or silencers, relocate the unit or construct total
enclosures or baffle walls. Contact a D
e
WALT service center or
call 1-800-4-D
e
WALT for assistance.
ELECTRICAL
Refer to all safety instructions before using unit. Observe
extension cord safety instructions if necessary. Always move the
On/Off switch (A) to the OFF position before removing the plug
from the outlet.
TRANSPORTING
When transporting the compressor in a vehicle, trailer, etc.,
ensure that the tank is drained and the unit is secured. Use care
when driving to avoid tipping the unit over in the vehicle. Damage
can occur to the compressor or surrounding items if the compressor
is tipped.
14
English
MOVING
When moving the compressor, grasp the handle and carry the
compressor as close to the body as possible.
WARNING: Risk of unsafe operation. Ensure proper footing and
use caution when carrying compressor to avoid a loss of balance.
PREPARATION FOR USE
Pre-Start Checklist (Fig. 1)
1.
Ensure the On/Off switch (A) is in the OFF position.
2.
Plug the power cord into the correct branch circuit receptacle.
See Voltage and Circuit Protection under Installation.
3. Ensure air tank is drained, see Draining Air Tank under
Maintenance.
4. Ensure the drain valve (H) is closed.
5. Ensure safety valve (G) is functioning properly, see Checking
Safety Valve under Maintenance.
6. Check pump oil level, see Compressor Pump Oil under
Maintenance.
CAUTION:
Do not operate without oil or with inadequate oil. DeWALT
is not responsible for compressor failure caused by inadequate oil.
7. Turn regulator knob (D) counterclockwise until fully closed.
Ensure regulated pressure gauge reads 0 PSI (0 kPa).
8. Attach hose and accessories.
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
9. Ensure all covers and labels are in place, legible (for labels) and
securely mounted. Do not use compressor until all items have
been verified.
WARNING: Risk of bursting. Too much air pressure causes a
hazardous risk of bursting. Check the manufacturer’s maximum
pressure rating for air tools and accessories. The regulator outlet
pressure must never exceed the maximum pressure rating.
Initial Set-up
(Fig. 1)
WARNING: Do not operate this unit until you read and understand
this instruction manual for safety, operation and maintenance
instructions.
BREAK-IN PROCEDURE
WARNING:
Serious damage may result if the following break-in
instructions are not closely followed.
This procedure is required before the air compressor is put into
service for the first time and when the check valve or a compres-
sor pump/motor has been replaced.
1. Ensure the On/Off switch (A) is in the OFF position.
NOTE: If hose is not connected to Quick Connect body, pull
coupler back until it clicks to prevent air from escaping through
the quick connect.
2.
Plug the power cord into the correct branch circuit receptacle.
See Voltage and Circuit Protection under Installation.
3. Open the drain valves (counter-clockwise) fully to permit air
to escape and prevent air pressure build up in the air tank
during the break-in period.
4. Move the On/Off switch to the ON position. The compressor
will start.
5. Run the compressor for 20 minutes.
6. After 20 minutes, close the drain valves by turning clockwise.
The tank will fill to cut-out pressure and the motor will stop.
7. Compressed air will be available until it is used or bled off.
15
English
OPERATING PROCEDURES
Start-up (Fig. 1)
1. Follow Pre-Start Checklist under Preparation for Use.
2. Move the On/Off switch to the ON position and allow tank pres-
sure to build. Motor will stop when tank pressure reaches
cut-out pressure.
CAUTION: Risk of unsafe operation. Compressed air from the unit
may contain wa ter condensation and oil mist. Do not spray un l-
tered air at an item that could be damaged by moisture. Some air
op er ated tools or de vic es may require ltered air. Read the in struc-
tions for the air tool or device.
3.Adjustregulator(D)todesiredsetting.SeeRegulator under
Features.
Shut-down (Fig. 1)
1 Move On/Off switch (A) is in the OFF position. NOTE: If finished
using compressor, follow Steps 2 - 6.
2. Turn regulator knob (D) counterclockwise until fully closed.
Ensure regulated pressure gauge reads 0 PSI (0 kPa).
3. Remove hose and accessory.
4. Drain the air tank,
see Draining Air Tank under Maintenance
.
Ensure air tank pressure gauge reads 0 PSI (0 kPa).
WARNING: Risk of bursting. Drain air tank daily. Water will condense
in air tank. If not drained, water will corrode and weaken the air tank
causing a risk of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing area.
MAINTENANCE
The following procedures must be followed when maintenance or
service is performed on the air compressor.
1. Ensure On/Off switch is in the OFF position.
2. Remove air compressor plug from outlet.
3. Drain air tank.
4. Allow air compressor to cool down before starting service.
NOTE: All compressed air systems contain maintenance parts
(e.g., oil, filters, separators) that are periodically replaced. These
used parts may contain substances that are regulated and must be
disposed of in accordance with local, state, and federal laws and
regulations.
NOTE: Take note of the positions and locations of parts during
disassembly to make reassembly easier.
NOTE: Any service operations not included in this section should
be performed by a D
e
WALT factory service center or a D
e
WALT
authorized service center.
16
English
WARNING: Risk of bursting. If the safety valve does not work
properly, over-pressurization may occur, causing air tank rupture or
an explosion.
Before starting compressor, pull the ring on the safety valve to
make sure that the safety valve operates freely. If the valve is
stuck or does not operate smoothly, it must be replaced with the
same type of valve.
Checking Air Filter Element (Fig. 1)
WARNING: Hot surfaces. Risk of burn. Aftercooler, pump head,
and surrounding parts are very hot, do not touch (see the Hot
Surfaces identied in Fig. 2). Allow compressor to cool prior to
servicing.
1. Ensure the On/Off switch (A) is in the OFF position.
2. Allow unit to cool.
3. Remove air filter (N) from unit.
4. Carefully pry filter top from base.
5. Remove element from filter base.
6. If element needs cleaning, blow out with air. Replace if need-
ed. Purchase replacement parts from your local dealer or
authorized service center. Always use identical replacement
parts.
7. Place element back in filter base.
8. Snap filter top to filter base.
9. Reassemble air filter to unit. Ensure exhaust outlet points
down.
CAUTION: Risk of unsafe operation. Do not operate without air
inlet lter
Maintenance Chart
Procedure Daily Weekly Monthly 1 year or
200 Hours
Check safety valve
X
Inspect air filter
+
X
Drain air tank
X
Check pump oil level
X
Change pump oil**
+
X
Oil leak inspection
X
Check for unusual noise/
vibration
X
Check for air leaks*
X
Clean compressor exterior
X
*Tocheckforairleaksapplyasolutionofsoapywateraroundjoints.
While compressor is pumping to pressure and after pressure cuts out,
look for air bubbles to form.
** The pump oil must be changed after the first 20 hours of operation.
Thereafter, when using
DeWALT
synthetic or SAE 40, non-detergent
air compressor oil, change oil every 200 hours of operation or once a
year, whichever comes first.
+ Perform more frequent in dusty or humid conditions
Checking Safety Valve (Fig. 1)
WARNING: Hot surfaces. Risk of burn. Aftercooler, pump head,
and surrounding parts are very hot, do not touch (see the Hot
Surfaces identied in Fig. 2). Allow compressor to cool prior to
servicing.
17
English
Draining Air Tank (Fig. 1)
WARNING: Risk of unsafe operation. Risk from noise. Air tanks
contain high pressure air. Keep face and other body parts away from
outlet of drain. Use safety glasses [ANSI Z87.1 (CAN/CSA Z94.3)]
when draining as debris can be kicked up into face. Use ear
protection [ANSI S12.6 (S3.19)] as air ow noise is loud when
draining.
NOTE: All compressed air systems generate condensate that
accumulates in any drain point (e.g. tanks, filter, aftercoolers,
dryers). This condensate contains lubricating oil and/or substances
which may be regulated and must be disposed of in accordance
with local, state, and federal laws and regulations.
1. Ensure On/Off switch is in the OFF position.
2. Move compressor into an inclined position so drain valve (H)
is at the lowest point (this will assist in removing moisture, dirt,
etc. from air tanks)
3. Place a suitable container under the drain valve to catch
discharge.
4. Grasp knurled knob on drain valve.
5. Slowly rotate knob to gradually bleed air from air tank.
WARNING: Risk of bursting. Drain air tank daily. Water will con-
dense in air tank. If not drained, water will corrode and weaken the
air tank causing a risk of air tank rupture.
CAUTION: Risk of property damage. Drain water from air tank may
contain oil and rust, which can cause stains.
6. When air tank pressure gauge reads 10 PSI (68,9 kPa), rotate
valve to the fully open position.
7. Close drain valve when finished.
Compressor Pump Oil (Fig. 1)
CHECKING OIL
WARNING: Hot surfaces. Risk of burn.
Aftercooler, pump head, and surrounding parts
are very hot, do not touch (see the Hot Surfaces
identied in Fig. 2). Allow compressor to cool prior
to servicing.
1. Ensure On/Off switch is in the OFF position.
2. Place unit on a flat level surface.
3. Remove dipstick (K) and wipe clean.
4. Reinsert dipstick fully into oil fill port for a
few seconds to allow oil to collect on the
dipstick.
5. Remove oil dipstick to read oil level. Oil should
not exceed top raised line on dipstick. If oil
is below lower mark, add same type of oil in
crankcase and follow Steps 4 - 6.
NOTE: When filling the crankcase, the oil flows
very slowly into the pump. If the oil is added too
quickly, it will overflow and appear to be full.
CAUTION: Risk of unsafe operation. Overlling with
oil will cause premature compressor failure. Do not
overll.
6. Replace dipstick.
CHANGING OIL
NOTE: Pump oil contains substances that are regulated and must
be disposed of in accordance with local, state and federal laws
and regulations.
WARNING: Hot surfaces. Risk of burn. Aftercooler, pump head, and
surrounding parts are very hot, do not touch (see the Hot Surfaces
identied in Fig. 2). Allow compressor to cool prior to servicing.
MAX
MIN
L
K
18
English
1. Ensure On/Off switch is in the OFF position.
2. Allow the unit to cool.
3. Remove air compressor plug from outlet.
4. Drain air tank.
5. Locate a suitable container under pump drain plug (L).
6. Remove the dipstick (K) from crank case.
7. Remove the oil drain plug (L).
8. Allow ample time for all oil to drain out. (Tilting the compressor
towards the drain plug will assist in draining.)
9. Install the oil drain plug.
10. Fill pump using DeWALT synthetic or SAE 40, non-detergent
air compressor oil.
11. Replace dipstick.
ACCESSORIES
Recommended accessories for use with your tool are available
for purchase from your local dealer or authorized service center.
If you need assistance in locating any accessory for your tool,
please contact D
e
WALT Industrial Tool Co., 701 East Joppa Road,
Baltimore, MD 21286, call 1-800-4-D
e
WALT (1-800-433-9258) or
visit our website www.dewalt.com.
CAUTION: The use of any other accessory not recommended for
use with this tool could be hazardous. Use only accessories rated
equal to or higher than the rating of the air compressor.
SERVICE INFORMATION
Please have the following information available for all service calls:
Model Number ____________ Serial Number _________________
Date and Place of Purchase ______________________________
Repairs
To assure product SAFETY and RELIABILITY, repairs, maintenance
andadjustmentshouldbeperformedbyaD
e
WALT factory service
center, a D
e
WALT authorized service center or other qualified
service personnel. Always use identical replacement parts.
Full One Year Warranty
DeWALT heavy duty industrial tools are warranted for one year from date of
purchase. We will repair, without charge, any defects due to faulty materials
or workmanship. For warranty repair information, call 1-800-4-D
e
WALT.
This warranty does not apply to accessories or damage caused where
repairs have been made or attempted by others. This warranty gives you
specific legal rights and you may have other rights which vary in certain
states or provinces.
LATIN AMERICA: This warranty does not apply to products sold in Latin
America. For products sold in Latin America, see country specific warranty
information contained either in the packaging, call the local company or
see website for warranty information.
FREE WARNING LABEL REPLACEMENT: If your warning labels become
illegible or are missing, call 1-800-4-D
e
WALT for a free replacement.
WARNING
ADVERTENCIA
RISK OF BURSTING. RUSTED TANK CAN CAUSE EXPLOSION.
DRAIN TANK AFTER EACH USE. TILT TANK TO FULLY DRAIN.
RISQUE DE RUPTURE. UN RÉSERVOIR ROUILLÉ PEUT EXPLOSER.
VIDER LE RÉSERVOIR APRÈS CHAQUE UTILISATION. INCLINER LE
RÉSERVOIR POUR LE VIDER COMPLÈTEMENT.
AVERTISSEMENT
TO REDUCE THE RISK OF INJURY, READ INSTRUCTION MANUAL BEFORE
OPERATING AIR COMPRESSOR
RISK OF BURSTING.
BEFORE STARTING THE COMPRESSOR, PULL THE RING ON
THE SAFETY VALVE TO
MAKE SURE THE VALVE MOVES FREELY.
MAKE SURE THE COMPRESSOR OUTLET PRESSURE IS
SET
LOWER THAN THE MAXIMUM OPERATING PRESSURE OF THE SPRAY GUN OR TOOL. NEVER WELD, DRILL
INTO, MODIFY OR OTHERWISE ATTEMPT TO REPAIR TANK.
RISK OF FIRE OR EXPLOSION. UNPLUG UNIT WHEN NOT IN USE. DO NOT SPRAY A FLAMMABLE OR COMBUSTIBLE
LIQUID OR PAINT NEAR SPARKS, FLAMES, PILOT LIGHTS, OR IN A CONFINED
AREA. THE SPRAY AREA MUST
BE WELL VENTILATED. KEEP COMPRESSOR
AT LEAST 20 FEET AWAY FROM SPRAY AREA. DO NOT CARRY AND
OPERATE
THE COMPRESSOR, OR ANY OTHER ELECTRICAL DEVICE NEAR THE SPRAY
AREA. NEVER SMOKE
WHEN SPRAYING. USE A MINIMUM OF 25 FEET OF HOSE TO CONNECT A SPRAY GUN TO THE
COMPRESSOR.
RISK OF PERSONAL INJURY. WEAR ANSI Z87 SAFETY GLASSES. NEVER SPRAY
COMPRESSED AIR OR MATERIAL AT
SELF OR OTHERS. DO NOT USE COMPRESSED
AIR FOR BREATHING. REGULATE PRESSURE TO ZERO BEFORE
DISCONNECTING HOSE.
RISK OF ELECTRICAL SHOCK. HAZARDOUS VOLTAGE. UNPLUG UNIT BEFORE REMOVING COVER. DO NOT
EXPOSE TO RAIN, STORE INDOORS.
PARA REDUCIR EL RIESGO DE LESIONES, LEA EL MANUAL DE INSTRUCCIONES ANTES DE ACCIONAR EL COMPRESOR DE AIRE
RIESGO DE ESTALLIDO.
ANTES DE ARRANCAR EL COMPRESOR, TIRAR DEL ANILLO EN LA VÁLBULA DESEGURIDAD PARA
ASEGURARSE QUE LA VÁLVULA SE MUEVE LIBREMENTE. ASEGÚRESE QUE LA VÁLVULA DE SALIDA DEL COMPRESOR ESTE
REGULADA POR DEBAJO DEL MÁXIMO DE LA PRESIÓN DE OPERACIÓN DE LA PISTOLA ROCIADORA O HERRAMIENTA. NE
JAMAIS SOUDER, PERCER, MODIFIER OU ESSAYER DE RÉPARER LE RÉSERVOIR.
RIESGO DE FUEGO O EXPLOSIÓN.
DESENCHUFE LA UNIDAD CUANDO NO LA UTILICE. NO ROCIAR LÍQUIDO NI PINTURAS
INFLAMABLES O COMBUSTIBLES CERCA DE CHISPAS, LLAMAS, LLAMAS DE PILOTO O EN ÁREAS CERRADAS. EL ÂREA
DE TRABAJO DEBE ESTAR BIEN VENTILADA. MANTENER EL COMPRESOR ALEJADO POR LO MENOS 20 PIES DEL AREA
DE PINTURA. NO LLEVAR NI OPERAR EL COMPRESOR NI DISPOSITIVO ELÉCTRICO ALGUNO CERCA DEL AREA DEL ROCIADO.
NUNCA FUME EN EL ÁREA DEL ROCIADO. USAR UNA MANGUERE DE UN MÍNIMO DE 25 PIES PARA CONECTAR LA PISTOLA AL
COMPRESOR.
RIESGO DE DAÑOS PERSONALES.
USAR GAFAS DE SEGURIDAD ANSI Z87. NUNCA APUNTAR EL CHORRO DE AIRE COMPRIMIDO
O DE MATERIAL QUE SE ESTÉ ROCIANDO A SÍ MISMO NI A OTRAS PERSONAS. NE RESPIRAR EL AIRE COMPRIMIDO. REDUCIR
LA PRESIÓN A CERO ANTES DEDESMONTAR LA MANGUERA.
RIESGO DE CHOQUE ELÉCTRICO.
ALTO VOLTAJE. DESCONECTAR LA UNIDAD ANTES DE QUITAR LA CUBIERTA. NO EXPONER A
LLUVIA. ALMACENAR EN INTERIORES.
LIRE LE MANUEL D'INSTRUCTIONS AVANT DE FAIRE FONCTIONNER LE COMPRESSEUR AFIN DE RÉDUIRE LE RISQUE DE BLESSURES.
RISQUE D'ECLATEMENT.
AVANT DE DÉMARRER LE COMPRESSEUR, TIREZ SUR L'ANNEAU DE LA SOUPAPE DE SÛRETÉ POUR VOUS
ASSURER QU'ELLE FONCTIONNE LIBREMENT. ASSUREZ-VOUS QUE LA PRESSION DE SORTIE DU COMPRESSEUR EST RÉGLÉE À UN
NIVEAU INFÉRIEUR À LA PRESSION D'UTILISATION MAXIMUM DU PISTOLET VAPORISATEUR OU DE L'ACCESSOIRE. NE JAMAIS
SOUDER, PERCER, MODIFIER OU ESSAYER DE RÉPARER LE RÉSERVOIR.
RISQUE D'INCENDIE OU D'EXPLOSION.
DÉBRANCHER L'APPAREIL DÈS LA FIN DE SON UTILISATION.NE PAS VAPORISER UN LIQUIDE OU UN
PEINTURE INFLAMMABLE OU COMBUSTIBLE PRÈS D'ÉTINCELLES, DE FLAMMES, DE VEILLEUSES NI DANS UN ENDROIT RESTREINT
OU
RENFERMÉ. L'AIRE DE VAPORISATION DOIT ÊTRE BIEN AÉRÉE. GARDEZ LE COMPRESSEUR À UNE
DISTANCE D'AU MOINS 20 PIEDS DE
LA SURFACE À VAPORISER. NE PORTEZ PAS LE COMPRESSEUR
ET NE L'UTILISEZ PAS NI AUCUN AUTRE APPAREIL ÉLECTRIQUE À
PROXIMITÉ DE L'AIRE DE
VAPORISATION. NE FUMEZ JAMAIS QUAND VOUS VAPORISEZ. UTILISEZ UN FLEXIBLE D'AIR D'UNE
LONGUEUR MINIMUM DE 25 PIEDS POUR RELIER LE PISTOLET VAPORISATEUR AU COMPRESSEUR.
RISQUE DE BLESSURES CORPORELLES.
PORTEZ DES LUNETTES DE PROTECTION ANSI Z87. NE DIRIGEZ
JAMAIS L'AIR COMPRIME OU
DES MATÉRIAUX VERS SOI OU VERS AUTRUI. NE JAMAIS UTILISER
DE L'AIR COMPRIMÉ POUR LA RESPIRATION. RÉGLEZ LA PRESSION À
ZÉRO AVANT DE RETIRER LE BOYAU.
RISQUE DE CHOC ÉLECTRIQUE.
VOLTAGE DANGEREUX. DEBRANCHEZ LA MACHINE AVANT D'ENLEVER BOITIER. N'EXPOSEZ PAS LE
COMPRESSEUR À LA PLUIE. REMISEZ-LE À L'INTÉRIEUR.
N170418
RIESGO DE ROTURA. LA OXIDACIÓN DEL TANQUE PUEDE PROVOCAR UNA
EXPLOSIÓN. DESAGOTE EL TANQUE DESPUÉS DE CADA USO. INCLINE EL
TANQUE PARA DESAGOTARLO COMPLETAMENTE.
ADVERTENCIA
WARNING
AVERTISSEMENT
WARNING
ADVERTENCIA
AVERTISSEMENT
A17566
DRENE EL TANQUE A DIARIO O DESPUÉS DE CADA USO. LA ACUMULACIÓN DE
ALLAF RACOVORP Y EUQNAT LED ORTNED NÓISORROC RANOISACO EDEUP NÓICASNEDNOC
DEL TANQUE. CONSULTE EL MANUAL PARA CONOCER LOS PROCEDIMIENTOS DE INSPECCIÓN. PARA DRENAR EL TANQUE,
ABRA LA VÁLVULA LENTAMENTE E INCLINE EL COMPRESOR PARAELIMINAR EL AGUA ACUMULADA.
RÉSERVOIR DE VIDANGE QUOTIDIEN
OU APRÈS CHAQUE UTILISATION. L'HABILLAGE
DE CONDENSATION PEUT CAUSER LA CORROSION À L'INTÉRIEUR DU RÉSERVOIR AYANT
POUR RÉSULTAT L'ÉCHEC DE RÉSERVOIR. VOIR LE MANUEL POUR DES PROCÉDURES D'INSPECTION. À LA VALVE
OUVERTE DE RÉSERVOIR DE VIDANGE LENTEMENT ET AU COMPRESSEUR D'INCLINAISON À L'EAU ACCUMULÉE VIDE.
DRAIN TANK DAILY OR AFTER EACH USE. CONDENSATION BUILD-UP MAY CAUSE CORROSION
INSIDE TANK RESULTING IN TANK FAILURE. SEE MANUAL FOR INSPECTION PROCEDURES. TO DRAIN TANK
OPEN VALVE SLOWLY AND TILT COMPRESSOR TO EMPTY ACCUMULATED WATER.
N118967
HOT SURFACE. RISK OF
BURNS. DO NOT TOUCH.
SUPERFICIE CALIENTE.
RIESGO DE QUEMADURAS.
NO TO CAR.
SURFACE TRÈS CHAUDE.
RISQUES DE BRÛLURES.
NE PAS TOUCHER.
19
English
GLOSSARY
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per minute; a unit of measure of air delivery.
PSI: Pounds per square inch; a unit of measure of pressure.
kPa (kilopascal): Metric pressure measurement. 1 kilopascal equal 1000 pascals.
Code Certication: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA
certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety.
Cut-In Pressure: While the motor is off, air tank pressure drops when accessory is used. When the tank pressure drops to a
certain low level the motor will restart automatically. The low pressure at which the motor automatically restarts is called cut-in
pressure.
Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to
a certain high pressure before the motor automatically shuts off, protecting your air tank from pressure higher than its capacity.
The high pressure at which the motor shuts off is called cut-out pressure.
Branch Circuit: The circuit carrying electricity from electrical panel to outlet.
Duty Cycle: For proper operation of your air compressor, it is recommended that a 50% duty cycle be maintained; that is, the air
compressor should not run more than 5 minutes in any 10 minute period.
20
English
Troubleshooting Guide
This section provides a list of the more frequently encountered malfunctions, their causes and corrective actions. The operator or
maintenance personnel can perform some corrective actions, and others may require the assistance of a qualified DeWALT technician
or your dealer.
Problem Code
Excessive air tank pressure-safety valve pops off ................................................................... 1,2
Air leaks ...................................................................................................................................3
Air leaks in air tank or at air tank welds .................................................................................. 4
Air leaks between head and valve plate .................................................................................5
Air leaks from safety valve .......................................................................................................6
Knocking Noise .........................................................................................................................6,16,17
Pressure reading on the regulated pressure gauge drops when an accessory is used ......7
Compressor is not supplying enough air to operate accessories ......................................... 8,9,10,11,12,15
Regulator knob has continuous air leak..................................................................................13
Regulator will not shut off air outlet ........................................................................................13
Moisture in pump crankcase ...................................................................................................14,18
Motor will not run .....................................................................................................................11,19,20,21,22,23,24,25,26
Troubleshooting Codes
CODE POSSIBLE CAUSE POSSIBLE SOLUTION
1 Pressure switch does not shut off motor when compressor
reaches cut-out pressure
Set the On/Off switch to OFF, if the unit does not shut off
contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
2
Pressure switch cut-out too high
Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
3
Tube fittings are not tight enough Tighten fittings where air can be heard escaping. Check
fittings with soapy water solution. Do Not Overtighten.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

DeWalt D55153 Manuel utilisateur

Catégorie
Compresseurs d'air
Taper
Manuel utilisateur

dans d''autres langues