Extron XTP T FB 202 Manuel utilisateur

Taper
Manuel utilisateur
User Guide
XTP T FB 202
XTP Systems
Two-input Universal Floor Box
Twisted Pair Transmitter
68-2374-01 Rev. E
01 19
Safety Instructions
Safety Instructions • English
WARNING: This symbol, ,when used on the product, is intended
to alert the user of the presence of uninsulated dangerous voltage within
the product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer darauf
aufmerksam machen, dass im Inneren des Gehäuses dieses Produktes
gefährliche Spannungen herrschen, die nicht isoliert sind und die einen
elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in der im
Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur
Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad
de Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du produit
d’une tension électrique dangereuse susceptible de provoquer un choc
électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf.
68-290-01, sur le site Extron, www.extron.com.
Istruzioni di sicurezza • Italiano
AVVERTENZA: Il simbolo, , se usato sul prodotto, serve ad avvertire
l’utente della presenza di tensione non isolata pericolosa all’interno del
contenitore del prodotto che può costituire un rischio di scosse elettriche.
ATTENTZIONE: Il simbolo, , se usato sul prodotto, serve ad avvertire
l’utente della presenza di importanti istruzioni di funzionamento e
manutenzione nella documentazione fornita con l’apparecchio.
Per informazioni su parametri di sicurezza, conformità alle normative,
compatibilità EMI/EMF, accessibilità e argomenti simili, fare riferimento
alla Guida alla conformità normativa e di sicurezza di Extron, cod. articolo
68-290-01, sul sito web di Extron, www.extron.com.
Instrukcje bezpieczeństwa • Polska
OSTRZEŻENIE: Ten symbol, , gdy używany na produkt, ma na celu
poinformować użytkownika o obecności izolowanego i niebezpiecznego
napięcia wewnątrz obudowy produktu, który może stanowić zagrożenie
porażenia prądem elektrycznym.
UWAGI: Ten symbol, , gdy używany na produkt, jest przeznaczony do
ostrzegania użytkownika ważne operacyjne oraz instrukcje konserwacji
(obsługi) w literaturze, wyposażone w sprzęt.
Informacji na temat wytycznych w sprawie bezpieczeństwa, regulacji wzajemnej
zgodności, zgodność EMI/EMF, dostępności i Tematy pokrewne, zobacz Extron
bezpieczeństwa i regulacyjnego zgodności przewodnik, część numer 68-290-
01, na stronie internetowej Extron, www.extron.com.
Инструкция по технике безопасности Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан
на продукте, предупреждает пользователя о наличии
неизолированного опасного напряжения внутри корпуса
продукта, которое может привести к поражению электрическим
током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: ,
www.extron.com, номер по каталогу - 68-290-01.
安全说明 简体中文
警告 产品上的这个标志意在警告用户该产品机壳内有暴露的危险 电压,
险。
注意 产品上的这个标志意在提示用户设备随附的用户手册中有
重要的操作和维护(维修说明
关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍
使用的特性等相关内容,敬请访问 Extron 网站 , www.extron.com,参见
Extron 安全规范指南,产品编号 68-290-01
안전 지침 • 한국어
경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에
대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및
규제 준수 안내서, 68-290-01 조항을 참조하십시오.
安全記事 • 繁體中文
警告: 若產品上使用此符是為了提醒使用者產品機殼內存
可能會導致觸電之風險的未絕緣危險電壓
注意 品上使用此符號,是為提醒使用設備隨附用戶手冊中
重要的操作和維(維修説明
有關安全性指導方針法規遵EMI/EMF 相容性、存取範和相主題的詳細
訊,請瀏覽 Extron 網站:www.extron.com然後《Extron 安全性與法規
守手冊準則編號 68-290-01
安全上の注意 日本語
警告: この が製品上に表示されている場合は、筐体内に絶縁され
いない高電圧が流れ、感電の危険があるこていま
意:この が製上に表示されている場合は、本機の取書に
されている重作と保()のについてユーザー
を喚起するものです
安全上の注意、法規厳守、EMI/EMF適合性、その他の関連項
スト イト www.extron.com よ り Extron Safety
and Regulatory Compliance Guide』 ( P/N 68-290-01) をご覧ださい。
Copyright
© 2015-2019 Extron Electronics. All rights reserved. www.extron.com
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks (
®
), registered service marks (
SM
), and trademarks (
TM
) are the property of RGBSystems, Inc. or
ExtronElectronics (see the current list of trademarks on the Terms of Use page at www.extron.com):
Registered Trademarks
(
®
)
Extron, Cable Cubby, ControlScript, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, Flat Field, FlexOS, Glitch Free. Global
Configurator, GlobalScripter, GlobalViewer, Hideaway, HyperLane, IPIntercom, IPLink, KeyMinder, LinkLicense, LockIt, MediaLink,
MediaPort, NetPA, PlenumVault, PoleVault, PowerCage, PURE3, Quantum, Show Me, SoundField, SpeedMount, SpeedSwitch,
StudioStation, SystemINTEGRATOR
, TeamWork, TouchLink, V-Lock, VideoLounge, VN-Matrix, VoiceLift, WallVault, WindoWall, XTP,
XTPSystems, and ZipClip
Registered Service Mark
(SM)
: S3 Service Support Solutions
Trademarks
(
)
AAP, AFL (Accu-RateFrameLock), ADSP(Advanced Digital Sync Processing), Auto-Image, CableCover, CDRS(ClassD Ripple
Suppression), Codec Connect, DDSP(Digital Display Sync Processing), DMI (DynamicMotionInterpolation), DriverConfigurator,
DSPConfigurator, DSVP(Digital Sync Validation Processing), eLink, EQIP, Everlast, FastBite, FOX, FOXBOX, IP Intercom HelpDesk,
MAAP, MicroDigital, Opti-Torque, PendantConnect, ProDSP, QS-FPC(QuickSwitch Front Panel Controller), RoomAgent, Scope-Trigger,
ShareLink, SIS, SimpleInstructionSet, Skew-Free, SpeedNav, Triple-Action Switching, True4K, Vector™ 4K , WebShare, XTRA, and
ZipCaddy
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause interference. This interference must be corrected at the expense of the user.
ATTENTION: The Twisted Pair Extension technology works with unshielded twisted
pair (UTP) or shielded twisted pair (STP) cables; but to ensure FCC Class A and CE
compliance, STP cables and STP Connectors are required.
For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the “Extron Safety and Regulatory
Compliance Guide” on the Extron website.
Conventions Used in this Guide
Notifications
The following notifications are used in this guide:
WARNING: Potential risk of severe injury or death.
AVERTISSEMENT : Risque potentiel de blessure grave ou de mort.
CAUTION: Risk of minor personal injury.
ATTENTION : Risque de blessuremineure.
ATTENTION:
Risk of property damage.
Risque de dommages matériels.
NOTE: A note draws attention to important information.
TIP: A tip provides a suggestion to make working with the application easier.
Software Commands
Commands are written in the fonts shown here:
^AR Merge Scene,,Op1 scene 1,1 ^B 51 ^W^C
[01] R 0004 00300 00400 00800 00600 [02] 35 [17] [03]
EX!*X1&*X2)*X2#*X2! CE}
NOTE: For commands and examples of computer or device responses mentioned
in this guide, the character “0” is used for the number zero and “O” is the capital
letter “o.”
Computer responses and directory paths that do not have variables are written in the font
shown here:
Reply from 208.132.180.48: bytes=32 times=2ms TTL=32
C:\Program Files\Extron
Variables are written in slanted form as shown here:
ping xxx.xxx.xxx.xxx —t
SOH R Data STX Command ETB ETX
Selectable items, such as menu names, menu options, buttons, tabs, and field names are
written in the font shown here:
From the File menu, select New.
Click the OK button.
Specifications Availability
Product specifications are available on the Extron website, www.extron.com.
Extron Glossary of Terms
A glossary of terms is available at http://www.extron.com/technology/glossary.aspx.
xXTP T FB 202 Floor Box Transmitter • Contents
Contents
Introduction ...............................................1
Guide Overview ................................................... 1
XTP T FB 202 Floor Box Transmitter
Description ......................................................... 1
System Compatibility ........................................... 2
Key Features ....................................................... 2
Installation .................................................4
Installation Overview ............................................ 4
Adapter Plates ..................................................... 5
Side Panel Connectors ........................................ 7
Connectors Below the Adapter Plates ............. 7
Connectors Above the Adapter Plates ............. 9
Top Panel Features .............................................. 9
Mounting ........................................................... 11
Ackermann GB3 (OBO Bettermann)
floor box ....................................................... 11
MK Electric CableLink Plus Single Pan
floor box ....................................................... 11
MK Electric CableLink Plus Modular
floor box ....................................................... 12
Electraplan or PUK floor box .......................... 12
Connection and Wiring Details ........................... 13
HDMI Connection .......................................... 13
TP Cable Termination and
Recommendations ....................................... 14
RS-232 and IR Over XTP Communication ..... 16
Power Connection ......................................... 17
Operation .................................................20
Switch Modes ................................................... 20
EDID .................................................................. 20
Reset Mode ....................................................... 20
SIS Configuration and Control .................21
Host Device Connection .................................... 21
SIS Overview ..................................................... 21
Host-to-Device and Device-to-Host
Communication ............................................ 21
Device-Initiated Message ............................... 21
Error Responses ............................................ 22
Using the Command and Response Tables
for SIS Commands ....................................... 22
Symbol Definitions ......................................... 22
Command and Response Tables for SIS
Commands ...................................................... 23
Input Commands ........................................... 23
Audio Configuration Commands .................... 23
Picture Adjustment Commands
(Analog Only) ................................................ 24
Presets Commands ....................................... 25
EDID Commands ........................................... 25
Advanced Configuration Commands ............. 25
XTP System Configuration Software ........26
Software Installation........................................... 26
Software Download Center Page ................... 26
Software Product Page .................................. 27
Software Operation............................................ 28
Connections .................................................. 28
Menu Bar ...................................................... 29
Device Settings .............................................. 32
XTP T FB 202 Floor Box Transmitter • Contents xi
XTP T FB 202 Floor Box Transmitter • Introduction 1
Introduction
This section contains general information about this guide and the Extron XTP T FB 202
Universal Floor Box Twisted Pair Transmitter, and selected device features. Topics in this
section include:
Guide Overview
XTP T FB 202 Floor Box Transmitter Description
Key Features
Guide Overview
This guide contains installation and control procedures, as well as reference information for
the XTP T FB 202 Universal Floor Box Twisted Pair Transmitter. In this guide, the terms
“XTP T FB 202” and “transmitter” are used interchangeably to refer to the XTP T FB 202
Universal Floor Box Twisted Pair Transmitter.
XTP T FB 202 Floor Box Transmitter Description
The Extron XTP T FB 202 is a two-input XTP transmitter that sends HDMI or digitized analog
video, audio, bidirectional RS-232 and IR, and Ethernet up to 330 feet (100 m) over a single
shielded twisted pair (STP) cable. It is HDCP compliant and supports 1080p @ 60 Hz
Deep Color and 1920x1200 signals. The XTP T FB 202 works with XTP Systems for
signal distribution and long-distance transmission between remote endpoints. It is made
specifically to fit into floor boxes from OBO Bettermann, MK by Honeywell, Electraplan, and
PUK.
The XTP T FB 202 can be powered locally or remotely through an Extron Power Injector or
XTP matrix switcher (see Power Connection on page 17).
The XTP T FB 202 can be configured and controlled with Extron Simple Instruction Set (SIS)
commands (see SIS Configuration and Control on page 21) or the XTP System
Configuration Software (see XTP System Configuration Software on page 26).
XTP T FB 202 Floor Box Transmitter • Introduction 2
The following diagram shows a typical application of the XTP T FB 202.
POWER
12V
HDMI
--A MAX
Rx GTx
RS-232 IR
RL
RxTx
-+ -+
1
2
AUDIO
OFF
ON
AUDIO
S/PDIF
RESET
LAN
SIG
LINK
XTP IN
OVER XTP
OUTPUTS
RELAYS
ACT
LINK
S
IG
LINK
XTP I
N
POWER
XTP T FB 202
VGA IN
HDMI IN
HDMI
VGA
HDCP
AUTO
CLIP
AUDIO IN
LAN
REMOTE
RS-232
-
+
G
Rx
Tx
12V
1.0 A MAX
CONF
IG
RESET
Tx
Rx
G
Tx
Rx
OVER XTP
RS-232
IR
XTP OUT
Ext
ron
XT
P T FB 202
XT
P Transmitter
Extron
XTP R HDMI
XTP Receiver
Shielded Twisted
Pair Cable
HDMI
HDMI
Display
Laptop
Figure 1. Typical XTP T FB 202 Application
System Compatibility
The XTP T FB 202 is compatible with XTP systems, but the maximum video resolution may
be limited with different XTP devices. See the table below for maximum video resolutions
and refresh rates for various XTP systems.
Output
Non-4K 4K Fiber 4K PLUS
Input
Analog 1920x1200 @ 60 Hz 1920x1200 @ 60 Hz 1920x1200 @ 60 Hz
Non-4K Digital 2048x1080 @ 60 Hz 2048x1080 @ 60 Hz 2048x1080 @ 60 Hz
4K Fiber 2048x1080 @ 60 Hz 4096x2160 @ 24 Hz 4096x2160 @ 24 Hz
4K PLUS 2048x1080 @ 60 Hz 4096x2160 @ 24 Hz 4096x2160 @ 60 Hz
Key Features
European floor box mountable — Provides a flexible, floor box mounting solution
that is compatible with offerings from OBO Bettermann - GB2 and GB3 slots, MK by
Honeywell, Electraplan, and PUK.
Reliable cable infrastructure — Provides high reliability and maximum performance
on an economical and easily installed cable infrastructure.
Inputs — Include one HDMI input and one VGA input.
Support for computer-video to 1920x1200, including HDTV 1080p/60 Deep
Color and 2K signals — Maintains superior image quality at the highest resolutions.
XTP T FB 202 Floor Box Transmitter • Introduction 3
Shielded twisted pair cable compatibility — Optimized for use with common
shielded twisted pair (STP) cable types. XTP systems fully support a maximum
transmission distance of 330 feet (100 meters) for all compatible resolutions when
used with shielded twisted pair cable. Shielded twisted pair cabling with solid center
conductor sizes of 24 AWG or better is recommended for optimal performance.
Digital conversion of analog video and audio input signals — Digitizes analog
signals, ensuring that a reliable, high quality digital video signal is sent to the output
destination.
Auto-input switching — Automatically switches to the highest or lowest priority input
with an active video signal for simplified operation.
Bidirectional RS-232 and IR insertion — Allows a remote display to be controlled
without the need for additional cabling through bidirectional RS-232 control and IR
signals inserted into the XTP output.
HDMI specification features — Support data rates up to 6.75 Gbps, Deep Color up
to 12-bit, 3D, and HD lossless audio formats.
HDCP-compliance — Ensures display of content-protected media and interoperability
with other HDCP-compliant devices.
EDID Minder — Automatically manages EDID communication between connected
devices to ensure that all sources properly power up and reliably display content.
Key Minder — Authenticates and maintains continuous HDCP encryption between
input and output devices to ensure quick and reliable switching in professional AV
environments, while enabling simultaneous distribution of a single source signal to one
or more displays.
Ethernet extension — Centralized 10/100 Ethernet communication can be
implemented via an Ethernet pass-through port to reduce the amount of independent
network drops required within a system.
Remote power capability — Allows the XTP T FB 202 to be powered by an XTP
CrossPoint Matrix Switcher or XTP Power Injectors to simplify integration.
Multiple embedded audio formats — Provides reliable operation with HDMI sources,
compatible with a broad range of multi-channel audio signals.
Selectable analog stereo audio input embedding — Supports unbalanced audio
for extended transmission. This feature enables direct connection of separate stereo
audio signals from a laptop, Blu-ray Disc™ player, or other device.
RS-232 control — Features an RS-232 serial port for control and configuration.
EDID and HDCP transmission — Allows continuous communication between source
and display by actively buffering DDC channels.
XTP compatibility — Provides a completely integrated solution for multiple digital and
analog formats through XTP integrated system products. XTP is a flexible, reliable signal
switching and distribution system.
XTP T FB 202 Floor Box Transmitter • Installation 4
Installation
This section contains information for installing, connecting, and wiring the XTP T FB 202.
Topics in this section include:
Installation Overview
Adapter Plates
Side Panel Connectors
Top Panel Features
Mounting
Connection and Wiring Details
Installation Overview
Install the XTP T FB 202 into an Ackermann GB3 (OBO Bettermann), MK Electric CableLink
Plus Modular, MK Electric CableLink Plus Single Pan, Electraplan, or PUK floor box.
CAUTION: Risk of personal injury. Failure to check the items listed below may result
in personal injury.
ATTENTION : Risque de blessure. La non-vérification des éléments listés
ci-dessous peut provoquer des blessures.
ATTENTION:
Failure to check the items listed below may result in property damage.
La non-vérification des éléments listés ci-dessous peut provoquer des dommages
matériels.
1. Check that the installation of the floor box meets government, building, electrical, and
safety codes.
2. Install the floor box according to the instructions of the manufacturer.
3. Prepare and pull the cables through the floor box.
TIP: Secure cables with clamps or ties to provide strain relief.
4. Trim back and insulate shields with heat shrink.
ATTENTION:
To prevent short circuits, the outer foil shield can be cut back to the point
where the cable exits the cable clamp. Both braided and foil shields should be
connected to an equipment ground at the other end of the cable.
Afin d’éviter les court circuits, le blindage en aluminium extérieur peut être
réduit jusqu’à ce que le câble sorte de la cosse de câble. Le blindage tressé et
le blindage en aluminium devraient être connectés à la masse d’un équipement
à l’autre bout du câble.
5. Install the appropriate adapters to the desired position in the floor box (see Adapter
Plates on page 5).
6. Connect cables to the side panel connectors located below the adapter plates (see
Connectors Below the Adapter Plates on page 7).
XTP T FB 202 Floor Box Transmitter • Installation 5
7. Mount the XTP T FB 202 to the floor box (see Mounting on page 11).
8. Connect appropriate devices to the remaining side (see Connectors Above the
Adapter Plates on page 9) and top (see Top Panel Features on page 9) panel
connectors.
9. Configure the XTP T FB 202 with SIS commands (see SIS Configuration and
Control on page 21) or the XTP System Configuration Software (see XTP System
Configuration Software on page 26).
Adapter Plates
Each floor box model requires a specific pair of provided adapter plates (see the table below
for the appropriate adapter plates to use with certain floor boxes).
Floor Box Adapter Plate Example
Ackermann GB3 (OBO Bettermann) 995241
995242
MK Electric CableLink Plus Single Pan 995243
MK Electric CableLink Plus Modular 995244
Electraplan 995300
PUK 995300
NOTE: The 995242 adapter plate is only used for position 2 of the Ackermann GB3
(OBO Bettermann) floor box.
1. Determine the position in the floor box to install the XTP T FB 202. Each compatible
floor box contains three positions to install devices (see figure 2).
NOTE: For the MK Electric CableLink Plus Single Pan floor box, do not use
position 2.
OBO Bettermann
GESR7 Floorbox Assembly
1
2
3
Figure 2. Three Positions in a Floor Box (Ackermann GB3 [OBO Bettermann]
Shown)
XTP T FB 202 Floor Box Transmitter • Installation 6
2. Insert the top flange of the adapter plate into a mounting slot that is no higher than the
third slot from the top.
Figure 3. Installing an Adapter Plate (995241 Shown) into a Mounting Slot
NOTES:
Install adapter plates in mounting slots of the same position in the floor box.
The MK Electric CableLink Plus Single Pan floor box does not have mounting
slots. Use a mounting screw to secure the large mounting hole of the 995243
adapter plate to the mounting hole of the floor box position (see figure 4).
MK Electric
CableLink Plus
Single Pan Floor Box
995243
995243
Figure 4. Installing 995243 Adapter Plates
3. Rotate the adapter plate down so the bottom flange rests against the wall of the floor
box.
Figure 5. Fixing the Adapter Plate (995241 Shown) in Place
XTP T FB 202 Floor Box Transmitter • Installation 7
4. If the desired position is position 2 of the Ackermann GB3 (OBO Bettermann) floor box,
use the provided screws to secure the 995242 adapter plate to a 995241 adapter plate.
Figure 6. Installing the 995242 Adapter Plate to a 995241 Adapter Plate
Side Panel Connectors
Connectors Below the Adapter Plates
1.0 A MAX
SIG LINK
XTP OUT
G
REMOTE
RS-232
Rx
Tx
POWER
12V
1.0A MAX
−+
Side Panel
B
A
C
A
Remote RS-232 connector (see page 7)
B
XTP output connector (see page 8)
C
Power connector (see page 8)
Figure 7. Side Panel Connectors Under the Adapter Plates
A
Remote RS-232 connector — Connect a host device to the 3.5 mm, 3-pole captive
screw connector for serial control of the transmitter. Wire the connector as shown in
figure 8.
Do not tin the wires!
Controlling
Device
Transmit(Tx)
Receive (Rx)
Ground(G)
Transmit (Tx)
Receive (Rx)
Ground (G)
Bidirectional
G Rx Tx
REMOTE
RS-232
Figure 8. RS-232 Wiring
XTP T FB 202 Floor Box Transmitter • Installation 8
B
XTP output connector — Connect a twisted pair cable to the RJ-45 connector
labeled “XTP OUT” (see figure 7,
B
on the previous page) and the XTP input
port on another XTP device to pass all signals (see TP Cable Termination and
Recommendations on page 14). This cable carries the following signals:
Digital video
Digital audio
Bidirectional RS-232 and IR commands
Remote power
Ethernet communication
System communication
Signal LED indicator — Lights green when the transmitter outputs a
video signal or a test pattern.
Link LED indicator — Lights yellow when XTP devices are connected
and communication is established.
ATTENTION:
Do not connect this connector to a computer data or telecommunications
network.
Ne connectez pas ce connecteur à un réseau de données informatiques ou à
un réseau de télécommunications.
XTP remote power is intended for indoor use only. No part of the network that
uses XTP remote power should be routed outdoors (see Remote power on
page 19).
XTP à distance est destiné à une utilisation en intérieur seulement. Aucune
partie du réseau qui utilise l’alimentation XTP à distance ne peut être routée en
extérieur (voir Remote power à la page 19).
C
Power connector — Connect an external power supply to the 3.5 mm, 2-pole
captive screw connector (see figure 7,
C
on the previous page). The Power LED
lights to indicate the device is receiving power. For wiring considerations, see Power
Connection on page 17.
NOTE: The XTP T FB 202 can also be powered remotely (see Remote power on
page 19).
Signa
l
Link
XTP T FB 202 Floor Box Transmitter • Installation 9
Connectors Above the Adapter Plates
1.0 A MAX
SIG LINK
XTP OUT
G
REMOTE
RS-232
Rx
Tx
POWER
12V
1.0A MAX
−+
Side Panel
E
D
Figure 9. Side Panel Connectors Above the Adapter Plates
D
HDMI input connector — Connect a digital video source device to the female HDMI
connector. It can accept HDMI, DVI (with an appropriate adapter), or dual mode
DisplayPort video sources.
NOTES:
The maximum HDMI cable length is 15 feet (4.6 meters).
Use an Extron LockIt Cable Lacing Bracket to secure the HDMI connector to
the device (see HDMI Connection on page 13).
E
Analog video input connector — Connect a video source to the female 15 pin HD
connector. It accepts RGBHV video.
Top Panel Features
CONFIG
LAN
G
RS-232 IR
Rx
Tx
Tx
Rx
HDMI IN
VGA IN
XTP T FB 202
HDMI
VGA
HDCP
AUTO
CLIP
AUDIO IN
OVER XTP
RESET
Top Panel
A
B
C
D
E
F
A
Audio input connector (see page 10)
B
RS-232 and IR Over XTP connector
(see page 10)
C
LAN connector (see page 10)
D
Reset button (see page 10)
E
Configuration port (see page 10)
F
LED indicators (see page 10)
Figure 10. Top Panel Features
XTP T FB 202 Floor Box Transmitter • Installation 10
A
Audio input connector — Connect an analog audio source to the 3.5 mm
tip-ring-sleeve (TRS) jack (see figure 10,
A
on the previous page). Both video inputs
can share this audio input.
Tip (+)
Sleeve ( )
Sleeve ( )
Ring (
-
)
Tip (+)
Audio Plugs.eps
RCA Connector
3.5 mm Stereo Plug Connector
(balanced)
Sleeve ( )
Ring (R)
Tip (L)
3.5 mm Stereo Plug Connector
(unbalanced)
Figure 11. Wiring for the TRS Connector
By default, audio input is selected automatically (see Audio input selection SIS
commands on page 23 to manually select audio inputs). When the HDMI input is
selected with automatic audio input selection, the transmitter prioritizes embedded
digital audio. The following table shows the audio format that is sent over the XTP
connection when a specific audio format is not specified.
Selected
Video Input
HDMI Embedded
Audio Present
Analog Audio
Present
Audio Sent Over XTP
VGA N/A Yes Analog audio
VGA N/A No No audio
HDMI Yes No HDMI embedded audio
HDMI Yes Yes HDMI embedded audio
HDMI No Yes Analog audio
HDMI No No No audio
B
RS-232 Over XTP port — To pass bidirectional serial signals between
XTP-compatible devices, connect a control device to the 5-pole captive
screw connector (see figure 10,
B
on the previous page). The port includes
only the 3 poles labeled “RS-232.”
IR Over XTP port — To transmit and receive IR signals (up to 56 kHz),
connect a control device to the 5-pole captive screw connector (see
figure 10,
B
on the previous page). This port includes the 2 poles labeled
“IR” and shares the ground pole with the RS-232 port.
NOTE: RS-232 and IR data can be transmitted simultaneously (see RS-232 and IR
Over XTP Communication on page 16 for wiring details).
C
LAN connector — Connect a control device or device to be controlled to this LAN
connector (see figure 10,
C
on the previous page) for 10/100 Ethernet communication
through this pass-through port. LEDs on this connector indicate link and activity status.
D
Reset button — Press and hold this button (see figure 10,
D
on the previous page)
to reset the device (see Reset Modes on page 20).
E
Configuration port — Connect a host device to the front panel USB mini-B
configuration port (see figure 10,
E
on the previous page).
F
LED indicators (see figure 10,
F
on the previous page)
Power LED indicator — Lights when power is applied.
HDMI LED indicator — Lights when an HDMI input signal is detected.
VGA LED indicator — Lights when a VGA input signal is detected.
HDCP LED indicator — Lights when the HDMI input signal is encrypted.
Auto LED indicator — Lights when the device is in auto switch mode.
Clip LED indicator — Lights when the analog audio input signal remains above
-3 dBFS. It remains lit for 200 ms after the signal falls below -3 dBFS.
IR
Tx Rx G Tx Rx
RS-232
IR
RS-232
XTP T FB 202 Floor Box Transmitter • Installation 11
Mounting
Before mounting the floor box, consider the mounting location and prepare the surface as
necessary.
1. If not already completed, install the appropriate adapter plates in the desired position
and mounting slots (see Adapter Plates on page 5).
2. Align the screw holes on the XTP T FB 202 with the screw holes on the adapter plates.
3. Using the provided self-threading screws and washers, secure the XTP T FB 202 to the
adapter plates (see figures 12 though 15).
Ackermann GB3 (OBO Bettermann) floor box
POWER
XTP T FB 202
VGA IN
HDMI IN
HDMI
VGA
HDCP
AUTO
CLIP
AUDIO IN
LAN
REMOTE
RS-232
-
+
G
Rx
Tx
12V
1.0 A MAX
C
ONFIG
RESET
Tx
Rx
G
Tx
Rx
OVER XTP
RS-232
IR
XTP OUT
POWER
XTP T FB 202
VGA IN
HDMI IN
HDMI
VGA
HDCP
AUTO
CLIP
AUDIO IN
LAN
REMOTE
RS-232
-
+
G
Rx
Tx
12V
A MAX
CONFIG
RESET
Tx
Rx
G
Tx
Rx
OVER XTP
RS-232
IR
XTP OUT
Extron
XTP T FB 202
(shown in OBO Bettermann
GESR7 floorbox assembly)
995242
995241
Figure 12. Mounting the XTP T FB 202 into an Ackermann GB3 (OBO Bettermann)
Floor Box
NOTE: Position 2 requires the installation of the 995242 adapter plate over one of the
995241 adapter plate.
MK Electric CableLink Plus Single Pan floor box
POWER
XTP T FB 202
VGA IN
HDMI IN
PWR
HDMI
VGA
HD
CP
AUTO
CLIP
AUDIO
IN
LAN
REMOTE
RS-232
-
+
G
Rx
Tx
12V
1.0 A MAX
CONFIG
R
ES
ET
Tx
Rx
G
Tx
R
x
OVER XTP
RS-2
32
IR
XTP OUT
POWER
XT
P T
F
B 202
VGA IN
HDMI IN
PWR
HDMI
VGA
HDCP
AUTO
CLI
P
AUDIO IN
LAN
REMOTE
R
S-232
- +
G
Rx
T
x
12V
A MA
X
CONFIG
RE
S
E
T
Tx
Rx
G
Tx
Rx
OVER XTP
RS-
232
IR
XT
P
O
WE
R
XTP T FB 202
V
GA IN
HDMI IN
P
WR
HDMI
VGA
HDCP
AUTO
CLIP
AUDIO IN
LAN
R
EMOT
E
R
S
-2
3
2
12V
A MA
X
CONF
IG
RESET
Tx
Rx
G
T
x
Rx
OVER XTP
RS-232
I
R
Extron
XTP T FB 202
(shown in Cablelink Single
Pan floorbox assembly)
995243
995243
Figure 13. Mounting the XTP T FB 202 into an MK Electric CableLink Plus Single
Pan Floor Box
NOTE: Do not install the XTP T FB 202 in position 2 (see figure 2 on page 5).
XTP T FB 202 Floor Box Transmitter • Installation 12
MK Electric CableLink Plus Modular floor box
POWER
XTP T F
B 202
VGA IN
HDMI
IN
PWR
HDMI
VGA
HDCP
AUTO
CLIP
AUDIO IN
LAN
REMOTE
RS-232
-
+
G
Rx
Tx
12V
1.0 A MAX
CO
NFIG
RESE
T
T
x
Rx
G
Tx
R
x
OVER XTP
RS-232
IR
XTP OUT
POWER
XTP T FB 202
VG
A IN
H
DMI IN
PWR
HDMI
VGA
HDCP
AUTO
CLIP
AUDI
O IN
LAN
R
EMOTE
RS-232
- +
G
R
x
T
x
12V
A MAX
CONFIG
RESET
Tx
Rx
G
Tx
Rx
OVER
XTP
RS-232
I
R
XTP OUT
Extron
XTP T FB 202
(shown in Cablelink Plus
modular floorbox assembly)
995244
995244
Figure 14. Mounting the XTP T FB 202 into an MK Electric CableLink Plus Modular
Floor Box
Electraplan or PUK floor box
POWER
XTP T FB 202
V
GA IN
HDMI IN
PWR
HDMI
VGA
HDCP
AU
TO
CLIP
AUDIO IN
LAN
REMOTE
RS-232
-
+
G
Rx
Tx
12V
1.0 A MAX
CONFIG
RES
ET
Tx
Rx
G
T
x
Rx
OVER XTP
RS-232
IR
XTP OUT
POWER
XT
P T
FB 202
VGA IN
HDMI IN
PWR
HDMI
VGA
HDCP
AUTO
CL
IP
AUDIO IN
LAN
REMO
TE
RS-232
-
+
G
Rx
T
x
12V
A
MAX
CONFIG
R
ESET
Tx
Rx
G
Tx
Rx
OVER XTP
RS-232
IR
XTP OUT
Extron
XTP T FB 202
(shown in Electraplan
oorbox assembly)
995300
995300
Figure 15. Mounting the XTP T FB 202 into an Electraplan or PUK Floor Box
XTP T FB 202 Floor Box Transmitter • Installation 13
Connection and Wiring Details
HDMI Connection
To secure the HDMI cable to the HDMI input connector, use an Extron LockIt Cable Lacing
Bracket and a tie wrap. The LockIt Cable Lacing Bracket can be applied to the top or the
side mounting screws. The following directions describe how to attach a LockIt Cable
Lacing Bracket to the top mounting screw.
3
1
2
3
4
5
Figure 16. Installing the LockIt Cable Lacing Bracket
1. Plug the HDMI cable into the panel connection (see figure 16,
1
).
2. Loosen the HDMI connection mounting screw from the panel (
2
) enough to allow the
LockIt to be placed over it. The screw does not have to be removed.
3. Place the LockIt on the screw and against the HDMI connector (
3
), and then tighten
the screw to secure the bracket.
4. Loosely place the included tie wrap around the HDMI connector and the LockIt (
4
).
5. While holding the connector securely against the cable lacing bracket, use pliers or
similar tools to tighten the tie wrap, then remove any excess length (
5
).
ATTENTION:
Connect and pull the tie wraps until they are secure. Do not overtighten.
Connectez et tirez les serre-câbles jusqu’à ce qu’ils soient sécurisés. Ne pas trop
serrer.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47

Extron XTP T FB 202 Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues