DELTA DORE Tywell 2050 Guide d'installation

Taper
Guide d'installation
Fixation / Mounting
Raccordement / Connection RF6050
2
3
230V~
50 Hz
OFF
Ê
Tywell ControlRF 6050
Tywell 2050
www.deltadore.com
09/22
1
4
12
60mm
2
3
3 x 1,5V - AAA LR03
5
Click
OU
OR
1
2
3
4
230V~
50 Hz
OFF
OR
OU
1
2
3
4
230V~
50 Hz
OFF
OR
OU
FR Noce d’installaon
EN Installaon guide
13.7°
19.5°
19
.8
230V~
50 Hz
5A - 230V~
L N
230V~
50 Hz
5A - 230V~
L N
Th
RF 6050
230 V~, 50 Hz - 1,8 VA
54 x 140 x 25 mm
IP IP 40
5 A max., 230V~
Tywell Control
3 x 1,5V - AAA LR03
92 x 92 x 19 mm
IP IP 30
868,7 Õ 869,2 MHz
100 Õ 300 m
Maximum radio power < 10 mW,
receiver category: 2
-10°C / +40°C
Important product information (Ë Í)
13.7°
19
.8
Mise en service / Activation RF6050
4
A la mise sous tension, le voyant de droite clignote :
Choix du mode (appuis brefs) /
When the device is switched on, the right indicator light fl ashes:
Mode selec on (press and release) /
ON
... ...
HEAT
HEA
T/COOL
COOL
.. .. ..... .. ..
... ... ...
230V~
50 Hz
Ë
RF 6050
Pilotage d’une vanne de zone
Zone valve control
Pilotage de l’entrée thermostat
Thermostat input control
Installation
1
Informations
Tywell Control
Ce produit doit être installé dans un
endroit thermiquement représentatif
de la pièce à réguler, à environ 1,50 m
du sol à l’abri de toute source de chaleur
(cheminée, infl uence du soleil, ...) et des
courants d’air (fenêtre, porte...). Pour
éviter des mouvements d’air parasites
qui fausseraient la mesure de la sonde
de température,
il est nécessaire de boucher l’arrivée des
ls dans la boîte d’encastrement (mastic,
laine de verre...).
IMPORTANT : Ne pas installer le
thermostat sur un mur en contact
avec l’extérieur ou avec une pièce non
chauffée (ex : garage...).
This product can be wall-mounted
or placed on a piece of furniture in a
room where the temperature is to be
regulated from, at a recommended
height of 1.5m and away from any heat
sources (fi replace, direct sunlight, etc.)
or draughts (window, door, etc.). To avoid
unwanted air movements that would
distort the sensor measurement, the
wire entry into the fl ush-mounted box
must be plugged (mastic, glass wool,
etc.).
IMPORTANT: Do not install the
thermostat on a wall in contact with the
outside or with an unheated room (e.g.
garage, etc.).
Mini 20 cm
Supprimer l‘association du récepteur / Remove Receiver Association
6
13.7° 19.5°
19.8
Températures
Températures
Réglages
Zone jour
56%
19.8°
08/12/2022
9:41
Températures
Températures
Températures
Autopilote volet
Zone jour
56%
19.8°
08/12/2022
9:41
x3
Oset de température
Réglages d’usine
Associer
Localiser le récepteur
Conrmer
Vous êtes sur le point de
désassocier le récepteur.
Désassocier
Désassociation
en cours…
16.7°
Installer
Réglages
Autopilote volet
Oset de température
Réglages avancés
Réglages d’usine
Associer
Désassocier
Désassocier
x3
> 5s
A partir du Tywell Control / With the Tywell Control
Associer le récepteur RF6050 au Tywell Control / Associate the RF6050 receiver with the Tywell Control
5
>3s
... ... ...
J’associe …
un Tywell Pro
J’associe …
un Tywell Pro
Associer
Association d’un récepteur
Pour associer un récepteur,
référez-vous à sa notice, et
lancez l’association.
Association
en cours… Le récepteur a été associé
avec succès !
Continuer
Associer un Tywell Pro ?
Oui
Non
Associer un Tywell Pro ?
Oui
Non
19.5°
19.8
un récepteur thermique un récepteur thermique
OFF
A partir du Tywell Control / With the Tywell Control
  • Page 1 1
  • Page 2 2

DELTA DORE Tywell 2050 Guide d'installation

Taper
Guide d'installation

dans d''autres langues