INFRARED BEAM PHOTOCELL FT30-AV
(23102160P)
English
The Photocell Kit Consists of:
1 No. Photocell Receiver
1 No. Photocell Transmitter
1 No. Fixing Kit
1 No. Set of fitting instructions
INSTALLATION
Transmitter
Insert the cables in the special seat and make the connections
according to the type of application, 12 or 24V~ or V , synchronized
or not synchronized.
-Adjust the cable within the unit to eliminate any surplus.
-Fix the unit.
-Seal the cover & cable entry to prevent insect infestation.
Technical Characteristics
Nominal range: 30 m
Signal: Modulated infrared
Wave length: 880 nm
Modulation Frequency: 1000 Hz
Supply Voltage: 12 - 24 V / V~
Absorbed Current: 30mA TX; 30mA RX
Temp. Operating Range: -15° C / +60° C
Relay Contact Rating: 1A max; 24V
Humidity: from 5% to 90% no
condensation
Receiver
-Insert the cables into the special seat and make the connections according to the type of application chosen for the transmitter,
12/24V~ or V , synchronized or not synchronized.
-Adjust the cable within the unit to eliminate any surplus.
-Make sure that the receiver is in frontal position, lined up on the same axis and in the same height of the associated transmitter. Act
on the lens adjustment if necessary (see fig.6-7).
-Seal the cover & cable entry to prevent insect infestation.
Once executed the preceding operations for both Tx and for Rx:
-Power supply the photocells 12-24V~ or V and verify their alignment. If the positioning, the alignment and the connection of the
photocells are correct, the red LED on the receiver will be switched on.
Please note: For the syncronized function, the power supply has to be necessarily of 12/24 V~ (alternating current).
Operational Verification
Fit one of the black plastic photocell covers complete with an opaque diffuser label stuck across the lens.
- Check that the relay works correctly.
- Check that the red led goes out when the beam is broken.
Red led Function:
RED LED LIT: ALIGNED
YELLOW LED ON: NOT ALIGNED OR BAD ALIGNMENT
SECURITY
The FT30-AV device cannot be used as security device (EN 12978).
INTENDED USE
The photocell FT30-AV has been projected to be used exclusivley as photoelectric barrier to be installed in the areas considered
dangerous and in proximity of the gate/ leaf.
ENVIRONMENT
Please dispose of this product packaging in a responsible, appropriate way.
CONFORMITIES
The FT30-AV photocell conforms to the following: 2004/108/CE (Act on the Electromagnetic Compatibility)
Correct Disposal of This Product (Waste Electrical & Electronic Equipment) - Europe only
(Applicable in the European Union and other European countries with separate collection systems)
This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes
at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please
separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for details of
where and how they can take this item for environmentally safe recycling.
STORING
When being transported this product must be properly packaged and handled with care
CLEANING AND MAINTENANCE
Cleaning and maintenance of this unit must be carried out at 6 monthly intervals by authorised, qualified personnel. During routine
Pag. 1
Rev. 01 - 02/201567411406P
STORAGE TEMPERATURES
Tmin Tmax Humiditymin Humiditymax
-20 °C +70 °C 5% no condensation 90% no condensation