HearthStone DVI 44 Manuel utilisateur

Catégorie
Poêles
Taper
Manuel utilisateur

Ce manuel convient également à

Hearthstone Quality Home Heating Products, Inc. ®
DVI-44 Model 8860
Manual: 6400-404##
R: 8/2/2012
DVI 44
(Model 8860)
GAS-FIRED
DIRECT-VENT INSERT
Owner's Manual
Installation
&
Operating Instructions
Read This Manual in Its Entirety
Operate And Maintain This Gas Heater According
To This Instruction Manual.
SAVE THESE INSTRUCTIONS!
.
WARNING: FOLLOW THE INFORMATION IN THESE
INSTRUCTIONS EXACTLY, IF NOT, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
WARNING: DO NOT STORE OR USE GASOLINE OR
ANY OTHER FLAMMABLE VAPORS AND LIQUIDS
NEAR THIS OR ANY OTHER GAS APPLIANCE.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch electrical switches; do not use the phone in
your building.
Immediately call your gas supplier from a phone outside
the structure. Follow your gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department or 911.
A qualified installer, service agency, or gas supplier must
perform installation and service of this appliance. In the
Commonwealth of Massachusetts, all installation of gas lines
and gas fittings must be performed by a licensed gas fitter or
licensed plumber.
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE
POUR RÉDUIRE AU MINIMUM LE RISQUE D’INCENDIE
OU POUR ÉVITER TOUT DOMMAGE MATÉERIEL,
TOUTE BLESSURE OU LA MORT.
AVERTISSEMENT: NE PAS ENTRESPOSER NI
UTILISER D’ESSENCE NI D’AUTRE VAPERURS OU
LIQUIDES INFLAMMABLES DANS LE VOISINAGE DE
CET APPRAREIL OU DE TOUT AUTRE APPAREIL.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
Ne pas tenter d’allumer d’appareil.
Ne touchez à aucun interrupteur. Ne pas vous servir des
téléphones se trouvant dans le batiment vous vous
trouvez.
Appelez immédiatement votre fournisseur de gaz depuis un
voisin. Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz, appelez
le service dos incendies.
L’installation et service doit être exécuté par un qualifié installer,
agence de service ou le fournisseur de gaz.
Intentionally Blank
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
3
Information Sheet
Use this page to record all relevant information concerning the purchase, installation, and maintenance of your
DVI 44 Model 8860 Direct-Vent Fireplace Insert. This information will facilitate servicing, purchase of
replacement parts, and warranty claims (if necessary). Keep your original receipt as proof of purchase.
Serial Number:
Fuel type:
Natural Gas
Liquid Propane
Sold by:
Date of Purchase:
Address:
Phone:
E-mail
Website:
Installed by:
Date of Installation:
Address:
Phone:
E-mail
Website:
Gas Supplier:
Address:
Phone:
E-mail
Read this Owner’s Manual before installing, or operating your DVI 44. Retain this manual for future reference.
SERVICE RECORD
Date
Who Performed Work
Work Performed
Notes:
WHAT WHEN
Firebox Cleaning............. annually
Glass Cleaning................ as needed
Door Gasket.................... Replacement as needed
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
4
Table of Contents
INTRODUCTION ........................................................................................................................................................... 5
SAFETY & GOOD PRACTICES ...................................................................................................................................... 6
SPECIFICATIONS ......................................................................................................................................................... 9
DVI 44 8860 Model Overview ................................................................................................................................... 11
Control Functions ..................................................................................................................................................... 14
INSTALLATION PREPARATION .................................................................................................................................... 16
Codes ....................................................................................................................................................................... 16
Items Required for Installation .................................................................................................................................. 16
Packing List .............................................................................................................................................................. 16
Unpacking and Inspection ........................................................................................................................................ 16
CLEARANCES TO COMBUSTIBLES .............................................................................................................................. 19
Clearance to Combustibles ...................................................................................................................................... 19
Hearth Requirement/Floor Protection ....................................................................................................................... 19
VENTING INFORMATION ............................................................................................................................................. 22
Venting Components ................................................................................................................................................ 22
ELECTRICAL SYSTEM INFORMATION .......................................................................................................................... 26
GAS SUPPLY & CONNECTIONS .................................................................................................................................. 27
Gas Connections ...................................................................................................................................................... 28
BAFFLE, LOG SET, & SCREEN PLACEMENT ............................................................................................................... 29
Installation of the Baffle ............................................................................................................................................ 29
Installation of the Log Set ......................................................................................................................................... 30
Completing the Installation ....................................................................................................................................... 30
Installation of the Screen .......................................................................................................................................... 31
Removal of Log Set .................................................................................................................................................. 31
Surround Installation ................................................................................................................................................. 32
Façade Installation ................................................................................................................................................... 32
LIGHTING & OPERATION ........................................................................................................................................... 33
Lighting Instructions .................................................................................................................................................. 33
Initial Adjustments .................................................................................................................................................... 33
Daily Operation ......................................................................................................................................................... 35
ROUTINE MAINTENANCE AND CARE ........................................................................................................................... 37
Cleaning ................................................................................................................................................................... 37
Monthly (or as needed): ............................................................................................................................................ 37
Annually: ................................................................................................................................................................... 37
As Needed: ............................................................................................................................................................... 39
REPLACEMENT PARTS & ACCESSORIES LIST ............................................................................................................. 40
TROUBLESHOOTING .................................................................................................................................................. 41
RATING LABEL ......................................................................................................................................................... 43
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
5
Introduction
Congratulations on your purchase of the DVI 44
Model 8860, Gas-Fired Direct-Vent Insert. The DVI
44, by Hearthstone, incorporates the latest in direct
vent gas technology, which will provide you with
ease of use, clean, and efficient heat for years to
come. The DVI 44’s copious glass, sleek styling, and
enameled or painted façade options gives the DVI
44 ambiance and a pleasing look that enhances any
room.
However, as with any gas appliance, the unit must
be properly and safely installed and maintained by
qualified service personnel to ensure safe and
trouble-free operation.
DVI 44 Model 8860 features:
1. The most realistic looking gas fire available
today with highly detailed logs.
2. Heat Wave® refractory firebox liner to reflect the
heat into your room in the most efficient way
possible.
3. Real Platinum glowing embers, for instant glow
and realism.
4. Child safety screen to reduce the risk of severe
burns on the front glass.
5. Smart thermostatic remote control with split
burner technology for a full range of heat output.
6. Integral, quiet, and efficient room air circulating
fan standard.
7. Battery backup to maintain basic functionality
during power outages (up to a week on fresh
batteries).
The Proflame System Features:
1. Thermostatic Remote Control
a. Twelve (12) flame levels, adjustable via
the remote
b. Split Burner control via remote
c. Six (6) blower speeds, adjustable via the
remote
d. Thermostatic mode to turn on/off based
upon room temperature.
e. “Smart” thermostatic mode to modulate
flame levels automatically as the unit
approaches the set point temperature.
f. Firebox Accent Light controlled by the
remote.
2. The option to toggle back and forth between an
Intermittent (IPI) or Continuous (CPI) pilot mode
via the remote.
a. The IPI (Summer) mode allows the most
efficient use of gas, burning the pilot
only when the thermostat calls for the
burner to ignite.
b. The CPI (Winter) mode runs the pilot
continuously keeping the firebox warmer
thus promoting better draft in colder
weather.
3. “Child-safe” lock-out on remote control.
4. “Low Battery” indicator for Transmitter on remote
control
Read this Owner’s Manual
Operate and maintain this gas heater according to
the instructions in this manual. For your safety, and
years of trouble free operation, read this manual in
its entirety.
Insert Must Be Installed and Maintained By
Qualified Service Personnel
Verify the gas connections and that venting systems
supply adequate combustion and ventilation air to
meet the requirements of local, regional or national
installation codes. Qualified service personnel must
inspect the gas heater before use, and at least
annually.
Manufactured & warranted by:
Hearthstone Quality Home heating Products, Inc.
317 Stafford Ave.
Morrisville, VT 05661
www.hearthstonestoves.com
inquiry@hearthstonestoves.com
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
6
Safety & Good Practices
Your DVI 44 is an attractive and extremely efficient
and easy to use heater, utilizing today’s best
technologies. By following a few simple safety
precautions and by performing minimal
maintenance, the unit will remain appealing while
providing years of quality performance.
The installation must conform to local codes or, in
the absences of local codes, the current National
Fuel Gas Code, ANSI Z223.1 (NFPA 54) or
CAN/CGA B149 Installation Code. (Installer
l’appareil selon les codes ou réglements locaux, ou,
en l’absence de tells réglements, selon les Codes
d’installation CAN/CGA B149.)
CAUTION: DO NOT USE THIS APPLIANCE IF ANY
PART WAS UNDER WATER. IMMEDIATELY CALL
A QUALIFIED SERVICE TECHNICIAN TO INSPECT
THE HEATER AND TO REPLACE ANY PART OF
THE CONTROL SYSTEM AND GAS CONTROL
THAT HAS BEEN UNDER WATER. (NE PAS SE
SERVIR DE CET APPAREIL S’IL A ÉTÉ PLONGÉ
DANS L’EAU, COMPLÉTEMENT OU EN PARTIE.
APPELER UN TECHNICIEN QUALIFIÉ POUR
INSPECTOR L’APPAREIL ET REMPLACER TOUTE
PARTIE DU SYSTÉME DE CONTRÔLE ET TOUTE
COMMANDE QUI ONT ÉTÉ PLUNGES DANS
L’LAU.)
During the first few hours of operation the appliance
may produce smoke and/or odor. This is normal
during the first several burns and also after long
periods when the stove is not burned. During these
initial burns, open a window(s) to assist in the
removal of the smoke/odor.
The appliance and its individual shutoff valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of ½ psig. (3.5k Pa). The
appliance must be isolated from the gas supply
piping system by closing its individual manual
shutoff valve during any pressure testing of the gas
supply piping system at test pressures equal to or
less than ½ psig (3.5k Pa).
Fire Hazard
Do not store or use gasoline, other flammable
vapors or liquids in the vicinity of this appliance.
Locate the DVI 44 out of traffic areas and away from
furniture, draperies, clothing, and flammable
material.
Vent Only to the Outside
Never vent the gas heater to other rooms or
buildings.
Service Caution
If you believe your DVI 44 is not in any way
performing properly, immediately discontinue
operation until the unit is inspected and approved by
qualified service personnel. Prior to servicing the
unit, turn the gas to the valve off, and disconnect
any electrical source. Ensure the unit is cool prior to
servicing and cleaning. Replace any safety screen,
guard, or component removed during servicing
prior to operation. (Tout écran ou protecteur retiré
pour permettre l’entretien de l’appareil doit être remis
en place avant de mettre l’appareil en marche.) Use of
any components not supplied by Hearthstone on the
stove voids all warranties. Do not substitute
components.
Proper Fuel
This gas heater is designed to burn natural gas (NG)
or with conversion, liquid propane (LP). Never burn
any fuel gas not intended for use with this unit.
Never burn paper, wood, or other materials in this
appliance.
This heater is factory equipped to burn natural gas
(NG). To burn propane (LP), you must purchase an
LP conversion kit 98-56601.
This appliance is only for use with the type(s) of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a
certified kit is used. Cet appareil doit être atilisé
uniquement avec les types de gas indiqués sur la
plaque signalétique. Ne pas l’utiliser avec d’autres
gas sauf si un kited conversion certifié est installé. )
WARNING: THIS GAS APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE SERVING A
SEPARATE GAS OR SOLID-FUEL BURNING
APPLIANCE
WARNING: DO NOT OPERATE THE APPLIANCE
WITH THE FRONT GLASS REMOVED, CRACKED,
OR BROKEN. REPLACEMENT OF GLASS
SHOULD BE DONE BY A LICENSED OR
QUALIFIED SERVICE PERSON. ONLY OPEN
FRONT FOR ROUTINE SERVICE. DO NOT SLAM
FRONT OR STRIKE GLASS. AVERTISSEMENT. NE
PAS UTILISER L’APPAREIL SI LE PANNEAU
FRONTAL EN VERRE N’EST PAS EN PLACE, EST
CRAQUÉ OU BRISÉ. CONFIEZ LE
REMPLACEMENT DU PANNEAU À UN
TECHNICIEN AGRÉÉ.
WARNING: HEARTHSTONE RECOMMENDS THAT
ONLY AN NFI CERTIFIED SERVICE TECHNICIAN
INSTALLS, AND REPAIRS THIS APPLIANCE. A
QUALIFIED SERVICE TECHNICIAN MUST
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
7
INSPECT THE APPLIANCE BEFORE USE, AND AT
LEAST ANNUALLY. MORE FREQUENT CLEANING
MAY BE REQUIRED DUE TO EXCESSIVE LINT
FROM CARPETING, BEDDING MATERIAL, PETS,
ETC. IT IS IMPERATIVE THAT THE CONTROL
COMPARTMENTS, BURNERS, AND CIRCULATING
AIR PASSAGES OF THE APPLIANCE ARE KEPT
CLEAN AND FREE OF OBSTRUCTIONS.
(L’INSTALLATION ET LA RÉPARATION DEVRAIT
ÊTRE CONFIÉES À UN TECHNICIEN QUALIFIÉ.
L’APPAREIL DEVRAIT FAIRE L’OBJET D’UNE
INSPECTION PAR UN TECHNICIEN
PROFESSIONNEL AVANT D’ÊTRE UTILISÉ ET AU
MOINS UNE FOIS L’AN PAR LA SUITE. DES
NETTOYAGES PLUS FRÉQUENTS PEUVENT
ÊTRE NÉCESSAIRES SI LES TAPIS, LA LITERIE,
ET CETERA PRODUISENT UNE QUANTITÉ
IMPORTANTE DE POUSSIÈRE. IL EST ESSENTIEL
QUE LES COMPARTIMENTS ABRITANT LES
COMMANDES, LES BRÛLEURS ET LES
CONDUITS DE CIRCULATION D’AIR DE
L’APPAREIL SOIENT TENUS PROPRES)
Hot Surfaces
Certain exposed surfaces of the DVI 44 will reach
high temperatures during normal operation.
Clearances to combustibles must be maintained, as
specified in the “Clearances To Combustibles”
section of this manual.
DUE TO HIGH TEMPERATURES THE APPLIANCE
SHOULD BE LOCATED OUT OF TRAFFIC AND
AWAY FROM FURNITURE, DRAPERIES,
CLOTHING AND FLAMMABLE MATERIALS. (EN
RAISON DES TEMPÉRATURES ÉLEVÉES,
L’APPAREIL DEVRAIT ÊTRE INSTALLÉ DANS UN
ENDROIT OÙ IL Y A PEU DE CIRCULATION ET
LOIN DU MOBILIER ET DES TENTURES.)
CHILDREN AND ADULTS SHOULD BE ALERTED
TO THE HAZARDS OF HIGH SURFACE
TEMPERATURES AND SHOULD STAY AWAY TO
AVOID BURNS TO SKIN OR CLOTHING IGNITION.
(LES ENFANTS ET LES ADULTES DEVRAIENT
ÊTRE INFORMÉS DES DANGERS QUE POSENT
LES TEMPÉRATURES DE SURFACE ÉLEVÉES ET
SE TENIR À DISTANCE AFIN D’ÉVITER DES
BRÛLURES OU QUE LEURS VÊTEMENTS NE
S’ENFLAMMENT.)
CAREFULLY SUPERVISE YOUNG CHILDREN
WHEN THEY ARE IN THE SAME ROOM AS THE
APPLIANCE. TODDLERS, YOUNG CHILDREN,
AND OTHERS MAY BE SUSCEPTIBLE TO
ACCIDENTAL CONTACT BURNS. A PHYSICAL
BARRIER IS RECOMMENDED IF THERE ARE AT
RISK INDIVIDUALS IN THE HOUSE. TO RESTRICT
ACCESS TO A FIREPLACE OR STOVE, INSTALL
AN ADJUSTABLE SAFETY GATE TO KEEP
TODDLERS, YOUNG CHILDREN, AND OTHER AT
RISK INDIVIDUALS OUT OF THE ROOM AND
AWAY FROM HOT SURFACES. (LES JEUNES
ENFANTS DEVRAIENT ÊTRE SURVEILLÉS
ÉTROITEMENT LORSQU’ILS SE TROUVENT
DANS LA MÊME PIÈCE QUE L’APPAREIL. LES
TOUT PETITS, LES JEUNES ENFANTS OU LES
ADULTES PEUVENT SUBIR DES BRÛLURES
S’ILS VIENNENT EN CONTACT AVEC LA
SURFACE CHAUDE. IL EST RECOMMANDÉ
D’INSTALLER UNE BARRIÈRE PHYSIQUE SI DES
PERSONNES À RISQUES HABITENT LA MAISON.
POUR EMPÊCHER L’ACCÈS À UN FOYER OU À
UN POÊLE, INSTALLEZ UNE BARRIÈRE DE
SÉCURITÉ; CETTE MESURE EMPÊCHERA LES
TOUT PETITS, LES JEUNES ENFANTS ET TOUTE
AUTRE PERSONNE À RISQUE D’AVOIR ACCÈS À
LA PIÈCE ET AUX SURFACES CHAUDES.)
CLOTHING OR OTHER FLAMMABLE MATERIAL
SHOULD NOT BE PLACED ON OR NEAR THE
APPLIANCE. (ON NE DEVRAIT PAS PLACER DE
VÊTEMENTS NI D’AUTRES MATIÈRES
INFLAMMABLES SUR L’APPAREIL NI À
PROXIMITÉ.)
CLEAN THE AREA AROUND, UNDER, AND
BEHIND THE UNIT ON A REGULAR BASIS TO
PREVENT THE ACCUMULATION OF DUST AND
LINT.
Ceramic Logs, & Burner
If the decorative ceramic log, or burner material
supplied with the DVI 44 are damaged or parts are
missing, they must be replaced with the same, or
approved Hearthstone replacement parts. These
components affect the combustion quality and safety
of the heater. Do not replace ceramic logs, or the
burner with unapproved ceramic components or any
other material.
We recommend you always wear gloves and safety
goggles while handling the ceramic log set, and
burner materials.
Electrical Hazard
Any three-prong grounded plug must be plugged
directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding
prong from any plug or otherwise attempt to
circumvent the grounding protection provided with
the unit. The DVI 44 must be electrically grounded in
accordance with local codes, or in the absence of
local codes, with the National Electrical Code,
ANSI.NFPA 70 in the U.S. or CSA C22.1 Canadian
Electrical Code in Canada.
Do Not Light Pilot or Burner by Hand
The pilot light on this gas heater is lit using an
electronic ignition module as described elsewhere in
this manual. Never attempt to light the pilot or main
burner by hand with a match or lighter.
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
8
Mobile Home Installations
This appliance may be installed in an aftermarket
permanently located, manufactured (mobile) home
(USA only), where not prohibited by local codes.
(Cet appareil peut être installé dans un maison
préfabriquée (mobile) déjá installée á demeure si les
réglements locaux le permettent.
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
9
Specifications
LISTED: Gas-Fired Direct-Vent Fireplace Heater
Model: DVI 44 Direct-Vent Gas Fireplace
Insert (8860)
Testing Agency: Intertek Testing Services
NA, Inc. (ITS)
Tested to: ANSI Z21.88-09, CSA 2.33-09,
CAN/CGA2.17-M91
Certified for Canada, CSA P.4.1-02
Approved for Mobile Home Installation (see
page 8)
Certified for use by:
Board of State Examiners of Plumbers & Gasfitters
100 Cambridge Street, Room 1511
Boston, MA 02202
www.mass.gov
Figure 1 - Model 8860 Dimensions (Inches)
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
10
Figure 2 8860 Minimum Fireplace Dimensions
Specification
NG
LP
INPUT RATING (Btu/hr) (0-610 m)
43,000
46,000
MAXIMUM OUTPUT (Btu/hr) (0-610 m)
28,478
31,496
MINIMUM INPUT (Btu/hr) (0-610m)
15,000
17,000
HIGH ALTITUDE RATING (Btu/hr) 610-1370 m
36,000
37,000
ORIFICE SIZE (DMS) 0-610 m (front/rear))
46F/38R
55F/53R
MANIFOLD PRESSURE - (in. W.c./kpa)
3.5/0.87
10.0/2.48
MANIFOLD PRESSURE - Low setting (in. W.c./kpa)
1.6/0.40
6.4/1.59
INLET PRESSURE - MINIMUM (in.w.c./kpa)
5.0/1.25
12.0/2.99
INLET PRESSURE-MAX (in. W.c./kPa) 14.0/3.47
10.5/2.6
14.0/3.47
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
11
NOTE: REMOVE FAÇADE & SURROUND FOR
COMPLETE ACCESS TO ELECTRICAL AND GAS
CONNECTIONS.
DVI 44 8860 Model Overview
Proflame 2 GTMFS System
The Proflame 2 GTMFS is a modular remote control
system that directs the functions of the DVI 44. The
Proflame 2 GTMFS System is configured to control
the on/off, main/split burner operation, its flame
levels, and provides Manual and Smart thermostatic
control of the hearth appliance. The system controls
two remotely actuated 120V/60Hz power outlets. The
Fan outlet controls the fan speed through six levels,
and the Auxiliary outlet, used for the firebox light,
either on or off. There is also an additional constantly
powered 120V/60Hz outlet. The system has battery
backup power for burner operation and control during
power outages (see page 13 for specifications).
Figure 3 Proflame 2 Remote Transmitter
Remote Transmitter
The DVI 44 comes equipped with a thermostatic
remote control transmitter. The easy to read LCD
display shows all functional abilities as well as a
childproof lockout and low battery indicator. It
displays room temperature readout, set temperature
readout and function status. The remote transmitter is
powered by three 1.5 volt AAA batteries. A Mode Key
is provided to index between the features and a
Thermostat Key is used to turn on/off or index
through thermostat functions.
Figure 4 Proflame 2 Battery Holder
Back-up Battery Holder- On/Remote/Off
Switch
The back-up battery holder is powered (6V DC) by
the Control Board and uses four 1.5 volt AA type
batteries for backup during power outages. The slider
switch is set to one of three positions: ON (Manual
Override), REMOTE (Remote Control) or OFF. The
ON selection turns the valve on (to high), and
activates the split flow setting last used if the Remote
becomes inoperative.
Figure 5 Proflame 2 Control Board
Proflame 2 Control Board
This is the command center for the appliance. The
Control Board allows the pilot to run in the
Intermittent (IPI) mode or the Constant (CPI) mode.
The pilot mode can be toggled between IPI and CPI
via the remote control. The Control Board signals the
burner to light or shut down and provides the ignitor
with the electricity needed for sparking. It is the main
power supply for the entire system when 120V power
is available or by the batteries in the Back-up Battery
Holder during a power outage.
The Control Board provides 120V power to control
the fan unit through 6 speeds and turns the Accent
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
12
Light on and off via the remote control. Neither the
Accent Light nor the blower will operate when 120V
power is not present.
The Control Board is equipped with a three-prong
(grounding) plug for protection against shock hazard
and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or
remove the grounding prong from the plug.
SIT Modulating Gas Valve
The remote transmitter can modulate the valve and
the flame to 6 different settings between high and off.
You can modulate the flame via the remote yourself
or by setting the remote control to one of the
thermostatic modes. In the thermostatic mode, the
stove will turn on/off based on the temperature set on
the remote. In the Smart thermostatic mode, as the
room temperature approaches the limit set for shut
down the valve will automatically gradually step down
the flame height. The reverse happens when the
room cools - the valve will automatically gradually
increase the flame height.
SIT Split Burner Solenoid
The remote transmitter can toggle between dual
burner, and single burner mode (46,000 Btu/hr (LP)
43,000 (NG) or 16,000 Btu/hr). The burner will turn
on/off.
Pilot Assembly
The pilot assembly consists of a pilot hood, sensor
rod, and ignitor. The ignitor sends a spark to the pilot
hood which ignites the gas and lights the pilot. With
the pilot lit the sensor rod is engulfed by the flame,
flame rectification occurs and the appliance remains
lit. If the sensor does not stay engulfed by the flame
the main burner will not light and the pilot will shut
down.
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
13
Figure 6 - Proflame GTMFS Component Specifications
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
14
Control Functions
Pilot Mode
Continuous Pilot (CPI): Running the DVI 44 in CPI mode will keep your pilot on even when the thermostat
does not call for heat and when the burner is not lit. This is an advantage in cooler temperatures or under windy
conditions. The “standing pilot” helps to keep the venting warm and generate some draft within the system. The
standing pilot also keeps the firebox and venting warm greatly minimizing, draft issues or condensation
formation on the glass during startup. The ignitor will automatically spark whenever the pilot mode is switched to
CPI, regardless of the position of the receiver switch. Hearthstone recommends the use of the CPI mode during
the heating season.
Intermittent Pilot (IPI): Using the IPI mode is a more efficient use of fuel as the pilot only ignites when the
thermostat calls for heat.
To switch back and forth between the two pilot modes 1) Press the OFF button on the remote 2) Press the
Mode button on the remote. 3) Press Up or Down on the center pad to toggle back and forth between the two
modes.
Back up Battery Holder- On/Remote/Off Switch
The Back-up Battery Holder is normally powered by the Proflame 2 Control Board or by four 1.5V AA batteries
during a power outage. This On/Remote/Off switch can be set to three different positions:
On: Manual override allowing the valve to function and ignite the burner without the remote transmitter. The
ignitor will spark automatically.
Remote: Remote Transmitter controls all functions of components.
Off: Turns off the stove. If CPI mode is selected, pilot will remain lit.
PRG Key: Used to synchronize the Transmitter and Receiver initially, and after each battery change (see page
38).
Figure 7 - Receiver Detail
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
15
Remote Transmitter
Figure 8 - Remote Transmitter Function Keys (remote color may differ from shown)
ON/OFF Key: Controls the insert.
Thermostat Key: This is the function that sets either
the Manual or Smart thermostatic control.
UP/Down Arrow Key: Adjusts the thermostat
temperature range, flame settings, split flow, and fan
speed.
Mode Key: Toggles through the component to be
controlled (split flow burner, blower or auxiliary
outlet)
The transmitter features a user-friendly layout with a
Blue LCD Screen for easier viewing.
See the instructions provided with the remote for
more operation details.
Figure 9 - Remote Transmitter Display Data
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
16
Installation Preparation
Codes
Adhere to all local codes or, in their absence, the
latest edition of THE NATIONAL FUEL GAS CODE
ANSI Z223.1 (NFPA 54) or CAN/CGA B149 (Installer
l’appareil selon les codes ou règlements locaux, ou,
en l’absence de tels glements, selon les Codes
d’installation CAN/CGA-B149.)
Installation Codes can be obtained from:
AMERICAN NATIONAL STANDARDS
INSTITUTE, INC.
1430 BROADWAY
NEW YORK, NY 10018
www.ansi.org
NATIONAL FIRE PROTECTION ASSOCIATION,
INC.
BATTERY MARCH PARK
QUINCY, MA 02269
www.nfpa.org
When installed, the appliance must be electrically
connected and grounded in accordance with local
codes or, in the absence of local codes, with the
current NFPA 70-National Electrical Code or CSA
C22.1-Canadian Electric Code.
A manufactured home (mobile) OEM installation must
conform to the Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280 (U.S.) or
Standard for Manufactured Home Installation,
ANSI/NCBCS A225.1 or Standard for Gas Equipped
Recreational Vehicles and mobile Housing, CSA
Z240.4.CAN/SCA Z240 MH (Canada). (Installer
l’appareil selon les codes ou règlements locaux, ou,
en l’absence de tels glements, selon les Codes
d’installation CAN/CGA-B149.)
This appliance is equipped for use at 0 to 2000 feet
(0-610 meters) altitude (refer to page 28). (Cet
appareil est equipè pour des altitudes compries entre
0 et 2000 pieds (0-610 m) seulement.)
WARNING: DO NOT INSTALL OR USE THIS
APPLIANCE IF ANY PART WAS SUBMERGED
UNDER WATER. IMMEDIATELY CALL A
QUALIFIED SERVICE TECHNICIAN TO INSPECT
THE HEATER AND TO REPLACE ANY PART OF
THE CONTROL SYSTEM AND GAS CONTROL
THAT WAS UNDER WATER. (NE PAS SE SERVIR
DE CET APPAREIL S’IL A ÉTÉ PLONGÉ DANS
L’EAU, COMPLÈTEMENT OU EN PARTIE.
APPELER UN TECHNICIEN QUALIFIÉ POUR
INSPECTOR L’APPAREIL ET REMPLACER TOUTE
PARTIE DU SYSTÈME DE CONTRÔLE ET TOUTE
COMMANDE QUI ONT É PLONGÉS DANS
L’LAU)
Items Required for Installation
Approved venting
External regulator (for propane (LP) only)
LP conversion kit, for propane only (not
included).
Piping which complies with local codes
Pipe sealant approved for use with
propane (LP) (resistant to sulfur compounds).
Sediment trap (see page 27)
120 volt, 15 Amp electrical service
Pipe wrench
Phillips head screwdriver
7/16-inch wrench
¼-inch wrench
Other parts as required by local code
Safety Glasses
Gloves
Packing List
1- DVI 44 8860 Gas-Fired Insert
1- Owner’s Packet Envelope (manual, warranty,
warranty card, Fireplace Warning Label, Flue
Tool)
4- Decorative Ceramic Logs (in box in firebox)
1- Safety Screen (on firebox)
1- Surround Assembly (box on pallet if applicable)
1- Façade Assembly (box on pallet if applicable)
1- Ceramic Baffle Set (box on Shipping Carton)
1- Accessory Packet (on pallet) containing:
1- Remote Control
1- Package of four AA Batteries
1- Package of three AAA Batteries
1- Bag of Platinum Bright Embers
1- Baffle Touch-up Paint
Note: Vent kits and components are supplied
separately. Failure to use the venting
components approved by Hearthstone for this
appliance will void your warranty.
Unpacking and Inspection
Hearthstone packages your DVI 44 to withstand
normal shipment without damage. However, damage
can still occur during transit. Take care to inspect for
damage when unpacking and installing the unit.
DO NOT INSTALL, OR PUT INTO SERVICE, A
DAMAGED OR INCOMPLETE HEATER.
Remove the shrink-wrap and all other packaging
materials taking care not to damage the stove’s
finish. Inspect the DVI 44 for visible or concealed
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
17
damage. The unit should be square and true. Any
sheet metal parts should be smooth and free of
bends and dents. If visible or concealed damage is
found or suspected, contact your dealer for
instructions.
Always use gloves and eye protection when handling
the decorative ceramic fire logs, and burner. Use
care when handling these parts as they are fragile
and subject to damage and breakage if handled
roughly.
See the firebox access instructions on page 188 and
remove the log set. Unpack and inspect the logs for
damage. Inspect the ceramic burner. Open the other
boxes and inspect the components. If log, burner, or
any other component damage is encountered,
contact your dealer for a replacement. Otherwise, set
the logs and other components aside until called for
during the installation.
Dismounting from Pallet
With all accessory boxes removed and set aside,
remove the shipping carton, then remove the 4 lag
screws and shipping clips that fasten the unit to the
pallet.
Have someone help lift the insert up and off the
pallet, taking care to avoid damaging components
mounted on the insert.
Figure 10 Shipping Clip Detail
Figure 11 Leveling Bolt Detail
Leveling Screws
If your hearth/fireplace surface in uneven, or is not
level, you can adjust the four provided leveling
screws. Adjust the screws using a ¼” wrench only
enough to keep the insert from rocking, or wobbling.
INSTALLER: Leave
this manual with the
appliance.
CONSUMER: Retain
this manual for future
reference.
«INSTALLATEUR :
Laissez cette notice avec
l’appareil.
CONSOMMATEUR :
Conservez cette notice
pour consultation
ultérieure.»
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
18
Firebox Access
1. If installed, remove the Façade.
2. Remove the front screen by lifting it up and off
the glass frame pulling it from behind the lower
glass retainer. Remove all packaging material
from the screen (if applicable).
3. Pull outward and then upward on the spring
loaded clips; rotate the clips to a generally
horizontal position. Tilt the top of the front panel
slightly outward to clear the tangs at its top.
Figure 12 Glass Frame Upper Mounting Detail
Figure 13 Rotate Spring Clips
Figure 14 Glass Frame Lower Mounting Detail
4. Lift the glass frame up out of the lower retainer
and set aside on a soft surface.
Figure 15 Tilt and Lift Glass Frame
1. See page 29 for log set installation instructions.
Reinstall components by reversing the previous
steps. Ensure you slide the lower glass frame
tangs behind the spring keepers. When
reinstalling the screen, ensure you insert the
bottom edge behind the lower glass retainer.
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
19
Clearances to Combustibles
Note: Ensure clearances are in accordance
with local installation codes and the
requirements of the gas supplier.
Clearance to Combustibles
Due to high surface temperatures, locate the unit out
of traffic areas and away from furniture and
draperies. Do not place clothing and other
flammable material on or near the heater. When
positioning the unit always maintain adequate
clearances around air openings into the combustion
chamber and allow for adequate ventilation and
servicing. Minimum clearances to combustibles must
be maintained as shown in the following figures.
Ensure you consider the need for access to the gas
control valve, gas piping, as well as full access for
periodic cleaning and servicing.
CAUTION: THESE CLEARANCES REPRESENT
MINIMUM DISTANCES IN ALL CASES, WHICH,
THROUGH TESTING IN AN INDEPENDENT
LABORATORY TO ANSI AND CSA STANDARDS,
WILL PREVENT FIRE OR SPONTANEOUS
COMBUSTION. WE DO NOT CONTROL THE
COMBUSTIBLE MATERIALS EXPOSED TO HEAT
BY THIS PRODUCT; THEREFORE, AN
ASSESSMENT MUST BE MADE BY THE
INSTALLER TO PREVENT CONSEQUENTIAL
DAMAGE OF WALLS AND FLOORING.
Hearth Requirement/Floor
Protection
The DVI 44 requires a non-combustible hearth, or
hearth pad that extends no less than 16” in front of
the unit. Installations must meet all local codes.
Figure 16 - Minimum Side Trim Clearances
Figure 17 - Mantle Clearances
Ensure the masonry fireplace and flue complies
with the applicable codes and both are clean and in
good condition. The Fireplace chimney must be
constructed of non-combustible materials. Repair
any damage before installation of the DVI-38 begins.
Prepare a zero clearance (metal) fireplace by
doing the following:
1. Install the label provided on the inside of the
firebox.
2. Remove the grate and block open the
damper.
3. If necessary, remove the smoke shelf,
internal baffles, refractory, log grates,
screen, masonry lining and glass doors.
(These components may be removed if they
are attached with mechanical fasteners.)
4. DO NOT cut, or remove any insulation, or
structural frame members.
5. DO NOT remove, or alter the metal sides,
floor, door frame, or face of the fireplace.
6. Ensure the chimney cleanout(s) fit and seal
properly.
Hearthstone Quality Home Heating Products, Inc. DVI-44 Model 8860
20
If the factory-built fireplace has no gas access
hole(s) provided, drill an access hole 1.5” in
diameter or less through the lower sides or bottom of
the metal zero clearance firebox in a proper
workmanship like manner. Remove sharp edges to
avoid damaging the gas line. This access hole must
be sealed with non-combustible insulation after the
gas supply line is installed. (Si le foyer préfabriqué
ne comporte pas d’orifices d’amenée du gaz, un
orifice d’au plus 37,5 mm (1,5 po) peut être pratiqué,
selon les règles de l’art, dans la partie inférieure des
parois ou au fond de la chambre de combustion. Cet
orifice doit être obturé au moyen d’isolant
incombustible une fois la conduite de gaz en place.)
Trim panels and surrounds shall not seal ventilation
openings in the fireplace. The minimum size
fireplace the DVI 44 insert will fit into is 35W x 24-
1/2” H x 18-1/2 D.
Installation of the Co-linear Vent Pipe
Mark each end of one of the flexible vent pipes
“intake” with a permanent marker. Mark each end of
the other flexible vent pipe “exhaust”.
Apply the high temperature silicone on the upper
portion of the vent (flex pipes to co-linear to co-
axial adaptor). Important: Ensure the pipe
connected to the exhaust on the stove connects
to the exhaust portion of the co-linear to co-axial
adaptor. Ensure you meet all the vent pipe
manufacturer’s requirements when installing the
adaptor and cap assembly. Follow the
manufacturer’s instructions when installing the
same. (The exhaust pipe on the co-linear to co-
axial adaptor is the pipe that is in the center of
the adaptor.)
Repeat this process to the top outer edge of
both the intake and exhaust collars on the top of
the unit. The exhaust port is on the right, the
intake port on the left, when viewed from the
front. Slide a hose clamp over the ends of both
flexible vent pipes. Place the flexible vent pipe
marked “intake” onto the intake port’s collar,
place the flexible vent pipe marked “exhaust”
onto the exhaust port’s collar. Secure the pipes
to the collars by tightening the hose clamps with
a slotted screwdriver or 5/16" nut driver.
Observe the following guidelines when installing the
vent pipes:
Do not install the venting into a chimney serving
another appliance, be it fossil fuel, solid fuel, or
another gas.
Do not crimp or rupture the vent pipes.
Installing the flue vent plate using the
Installation Tool
1. You will need to remove the Flue Vent Plate
from the stove before you place the insert into
the fireplace.
2. Locate the Flue Vent Plate on the top of the
insert.
3. Using a Phillips head screwdriver, remove the
screw holding the front of the Flue Vent Plate to
the firebox. Push the plate carefully back and
out of the retaining tracks take it off the stove
as shown (see Figures 18 &19). Keep this
screw, as you will need it later to remount the
plate.
Figure 18
4. Attach the 4 Exhaust flex pipe to the RIGHT
side of the Flue Vent Plate. (facing the front of
the stove) Attach the 3” Inlet flex pipe to the Left
side of the Flue Vent Plate.
5. Carefully position the DVI 44 in front of the
fireplace opening. Slowly slide the insert back so
the rear of the insert is just inside the fireplace.
Start the Flue Vent Plate underneath the
Retaining Tracks on the top of the insert. (See
Figure 19) The Retaining Tracks will ensure a
tight seal for the flue gases when the plate is
fully seated.
6. Locate the Installation Tool. Slide the end of the
tool with the threads though the Mounting Point
hole on the firebox bracket.
7. Thread the Installation Tool into the front of the
Flue Vent Plate.
Mounting Point for
5/32 screw and
Installation Tool.
Flue Vent
Plate
Mounting
Point for
screw and
Installation
Tool.
3”Intake
4”Exhaust
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

HearthStone DVI 44 Manuel utilisateur

Catégorie
Poêles
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues