IS-45916-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
3) Make wire connecons. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
4) Push xture[E] to wall. Be sure not to pinch wires
between wall and canopy of xture. Note: The xture
can be mounted with the glass in the up posion or the
down posion.
5) Screw in two (2) mounng screws[D], one on each side
of canopy.
6) Install the supplied G9 bulb[F] by pushing into the
socket. Cauon: Do not touch the bulb with bare hands,
use a rag to prevent oil from your skin from geng on
the bulb surface.
7) Install the bulb cover[G] by placing over the installed
bulb and screwing into place over the socket.
8) Install the glass globe[H] over the installed bulb cover
and screw into place.
Fixture Diagram
Parts List
[A] Mounting
Strap
[B] Outlet Box
[C] Strap
Mounting
Screws
[D] Mounting
Screws
[E] Fixture
[F] G9 Bulb
[G] Bulb Cover
[H] Glass Globe
Installaon Instrucons
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
Warning:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons (connued)
A
C
B
D
H
G
E
F
1) Aach mounng strap[A] to outlet box[B] using the two
(2) strap mounng screws[C]. The mounng strap can be
adjusted to suit posion of xture.
2) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, then thread into
mounng strap.
If xture is provided with ground wire. Connect xture
ground wire to outlet box ground wire with wire
connector (Not provided) aer following the above steps.
Never connect ground wire to black or white power
supply wires.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b