Avantco 178GF25HC Manuel utilisateur

Taper
Manuel utilisateur
Commercial Glass Froster/Plate
Chiller User’s Manual
- 1 -
User Manual
Commercial Glass Frosters:
178GF25HC, 178GF25HCS, 178GF36HC, 178GF36HCS,
178GF50HC, 178GF50HCS
Please read the manual thoroughly prior to equipment set-up,
operation and maintenance.
10/2020
- 2 -
User Manual
Warning
DANGER – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BY
TRAINED SERVICE PERSONNEL. DO NOT PUNCTURE REFRIGERANT TUBING.
PELIGRO - RIESGO DE INCENDIO O EXPLOSION. REFRIGERANTE INFLAMABLE UTILIZADO. PARA
SER REPARADO SOLAMENTE POR PERSONAL DE SERVICIO CALIFICADO. NO PINCHAR LA TUBERÍA
REFRIGERANTE.
DANGER – RISQUE DE FEU OU D’EXPLOSION. LE FRIGORIGÈNE EST INFLAMMABLE. CONFIER LES
RÉPARATIONS À UN TECHNICIEN SPÉCIALISÉ. NE PAS PERFORER LA TUBULURE CONTENANT LE
FRIGORIGENE.
CAUTION – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. CONSULT REPAIR
MANUAL/OWNER’S GUIDE BEFORE ATTEMPTING TO SERVICE THIS PRODUCT. ALL SAFETY
PRECAUTIONS MUST BE FOLLOWED.
ATENCION - RIESGO DE INCENDIO O EXPLOSN. REFRIGERANTE INFLAMABLE UTILIZADO. CONSULTE
EL MANUAL DE REPARACIÓN / GUÍA DEL PROPIETARIO ANTES DE INTENTAR DAR SERVICIO A ESTE
PRODUCTO. DEBEN CUMPLIR CON TODAS LAS PRECAUCIONES DE SEGURIDAD.
ATTENTION – RISQUE DE FEU OU D’EXPLOSION. LE FRIGORIGÈNE EST INFLAMMABLE. CONSULTER LE
MANUEL DU PROPRIÉTAIRE/GUIDE DE RÉPARATION AVANT DE TENTER UNE RÉPARATION. TOUTES LE
MESURES DE SÉCURIDOIVENT ÊTRE RESPECTÉES.
CAUTION – RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGERANT TUBING; FOLLOW
HANDLING INSTRUCTIONS CAREFULLY. FLAMMABLE REFRIGERANT USED.
ATENCION - RIESGO DE INCENDIO O EXPLOSN DEBIDO A LA PERFORACION DE LA TUBERÍA
REFRIGERANTE; SIGA LAS INSTRUCCIONES DE MANIPULACIÓN CON CUIDADO. REFRIGERANTE
INFLAMABLE UTILIZADO.
ATTENTION – RISQUE DE FEU OU D’EXPLOSION SI LA TUBULURE CONTENTANT LE FRIGORIGÈNE
EST PERFORÉE; SUIVRE LES INSTRUCTIONS DE MANUTENTION AVEC SOIN. LE FRIGORIGÈNE EST
INFLAMMABLE.
CAUTION – RISK OF FIRE OR EXPLOSION DUE TO FLAMMABLE REFRIGERANT USED. FOLLOW
HANDLING INSTRUCTIONS CAREFULLY IN COMPLIANCE WITH LOCAL GOVERNMENT REGULATIONS.
ATENCIÓN – RIESGO DE INCENDIO O EXPLOSN DEBIDO A REFRIGERANTE INFLAMABLE UTILIZADO.
SIGA LAS INSTRUCCIONES DE MANIPULACIÓN CON CUIDADO CONFORME A LAS REGLAS DE LA
MUNICIPALIDAD.
ATTENTION – RISQUE DE FEU OU D’EXPLOSION SI LE FRIGORIGÈNE EST INFLAMMABLE. SUIVRE
LES INSTRUCTIONS DE MANUTENTION AVEC SOIN CONFORMÉMENT AUX RÈGLEMENTATION
GOUVERNEMENTALE LOCAUX.
- 3 -
User Manual
Installation
Please read this manual thoroughly prior to equipment set-up, operation and maintenance.
Important!!! Please Read Before Installation
If the unit has recently been transported on its side, please let the unit stand upright for a
minimum of 24 hours before plugging it in.
• Make sure the unit has reached the desired temperature before loading the unit with products.
• Make sure all accessories are installed (shelves, shelf clips, etc) before plugging in the unit.
Do not attempt to remove or repair any component of the unit. Consult an authorized service
technician for servicing / repair.
• Do not hang on doors or stand inside the unit.
• Please read through this manual in its entirety.
Cabinet Location Guides
Install the unit on a strong and leveled surface.
- If the surface is uneven, the unit may be noisy.
- The unit may malfunction if the surface is uneven.
• Install the unit in an indoor, well ventilated area.
- For best performance, maintain 6 of clearance on both sides and the back of the unit at all times.
- Outdoor use may cause decreased efficiency and damage to the unit.
- Avoid direct sunlight.
• Avoid installation in a high humidity and / or dusty area.
- High humidity can cause the unit to rust and may decrease efficiency.
- Dust collected on the condenser coil may cause unit to malfunction.
- Malfunction due to high ambient temperatures, humidity, or improperly maintained
condenser coil will void the warranty.
• Select a location away from heat and moisture-generating equipment.
- High ambient temperatures may cause the compressor to malfunction.
- Malfunction due to high ambient temperatures and humidity will void the warranty.
- 4 -
User Manual
Electrical
• Please ensure that the required voltage is being supplied at all times.
The unit should be plugged into a grounded and properly-sized electrical outlet with appropriate
over-current protection. Please refer to the electrical requirements on the unit’s nameplate.
• The unit should have its own dedicated outlet.
• Do not use extension cords.
• Ensure the unit is not resting on or against the electrical cord.
• If the unit is not in use for a long period of time, please unplug the unit from the outlet.
• To avoid shock and fire hazards, do not plug in or unplug the unit with wet hands.
After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to do so could
cause damage to the compressor.
Adjusting the Temperature
Your new freezer is already factory-set to run at optimum
temperatures for food safety and should require no
adjustments.
Freezers are set to cycle between a minimum temperature of -5 degrees Fahrenheit and a maximum
temperature of 2 degrees Fahrenheit.
Adjusting the temperature changes the minimum temperature your unit will run at. Your unit will not
run constantly at this setting. To change it, follow these instructions:
Digital Control Units
• Hold “SET” for 1 sec. The display will flash the current minimum temperature.
• Use the arrow buttons to adjust the minimum temperature you want it to run at.
• Press “SET” again to save your settings
Always remember to calculate the differential if you change the minimum temperature setting. The
cabinet temperature will fluctuate up to +7 degrees over your set minimum temperature as the
compressor runs and shuts off. Setting the temperature too high will result in unsafe maximum
temperatures and possible health code violations.
Prg
mute
Set
aux
def
Freezer Control
- 5 -
User Manual
Operation/Maintenance
NOTE: We strongly recommend that any servicing be performed by an authorized service technician.
Cleaning the Condenser Coil
• For efficient operation, keep the condenser surface free of dust, dirt, and lint.
• We recommend cleaning the condenser coil at least once per month.
Clean the condenser with a commercial condenser coil cleaner, available from any kitchen
equipment retailer.
Cleaning the Fan Blades and Motor
• If necessary, clean the fan blades and motor with a soft cloth.
• If it is necessary to wash the fan blades, cover the fan motor to prevent moisture damage.
Cleaning the Interior of Unit
• When cleaning the cabinet interior, use a solvent of warm water and mild soap.
• Do not use steel wool, caustic soap, abrasive cleaners, or bleach that may damage the interior finish.
Wash door gaskets on a regular basis, preferably weekly. Simply remove the door gasket from the
frame of the door, soak it in warm water and soap for thirty (30) minutes, then dry with soft cloth
and replace.
• Check door gaskets for proper seal after they are replaced.
Periodically remove the shelves and shelf brackets from the unit, and clean them with a mild soap
and warm water.
Defrost System
Refrigerator coils are kept below the freezing point (32 degrees Fahrenheit). During compressor
down-time, the evaporator fan continues to circulate air through the evaporator coil. This air
circulation raises the coil temperature above the freezing point, melting any accumulated frost.
Run-off water is drained into the evaporator pan and evaporated. Freezer coils are defrosted
electrically. Automatic defrost timers automatically initiate at pre-set intervals and for a
pre-determined duration.
- 6 -
User Manual
Troubleshooting
Compressor is Not Running
Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker.
Power cord unplugged. Plug in power cord
Thermostat set too high. Set thermostat to lower temperature.
Cabinet in defrost cycle. Wait for defrost cycle to finish.
Condensing Unit Runs for Long Periods of Time
Excessive amount of warm product placed in cabinet. Allow adequate time for product to cool down.
Prolonged door opening or door ajar. Ensure doors are closed when not in use. Avoid opening
doors for long periods of time.
Dirty condensor coil. Clean the condensor coil.
Evaporator coil iced over. Unplug unit and allow coil to defrost. Make sure
thermostat is not set too cold. Ensure that door gasket(s)
are sealing properly.
Cabinet Temperature is too Warm
Thermostat is set too warm. Set thermostat to lower temperature.
Airflow is blocked. Re-arrange products to allow for proper air flow. Make
sure there is at least four inches of clearance from the
evaporator.
Excessive amount of warm product placed in the cabinet. Allow adequate time for product to cool down.
Fust blown or circuit breaker tripped. Replace fuse or reset circuit breaker.
Dirty condensor coil. Clean the condensor coil.
Prolonged door opening or door ajar. Ensure doors are closed when not in use. Avoid opening
for long periods of time.