6
HOW TO VIEW THE SET TEMPERATURE
1. Push and immediately release the SET key, the set temperature will be displayed.
2. To return to standard view, wait about 5 seconds or push and immediately release the SET key
again.
HOW TO CHANGE THE SET TEMPERATURE
1. Push and hold the SET key for 2 seconds.
2. The °F LED will start to blink and the current temperature will be displayed.
3. To change the set temperature push the or arrows.
4. Push the SET key to store the new temperature or wait 10 seconds and new temperature will
automatically be set.
HOW TO START A MANUAL DEFROST
NOTE: Units are pre-programmed to run automatic defrost cycles at preset intervals. If you would like to
run a manual defrost cycle at any time, follow these instructions:
1. Push and hold the key for 2 seconds.
2. Repeat to stop the defrost cycle.
Refrigerator coils are kept below the freezing point (32°F). During compressor down-time, the
evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil
temperature above the freezing point, melting any accumulated frost. Run-off water is drained into the
evaporator pan and evaporated.
OPERATION/MAINTENANCE
NOTE: It is strongly recommend that any servicing be performed by an authorized service technician.
During maintenance and cleaning, please unplug the unit.
LOADING PRODUCTS
Do not block the inside air duct/fan at the top of your refrigerator. Maintain a minimum clearance
of 4” between products and the fan at all times.
Ensure all shelves are level and properly secured prior to loading products.
Do not store flammable and/or explosive gas or liquids inside the unit.
CLEANING THE CONDENSER COIL
For efficient operation, keep the condenser surface free of dust, dirt and lint.
We recommend cleaning the condenser coil at least once per month.
Clean the condenser with a commercial condenser coil cleaner, available from any kitchen
equipment retailer.