Goldstar GP120CE Le manuel du propriétaire

Taper
Le manuel du propriétaire
PORTABLE AIR
CONDITIONER
USER’ S GUIDE & INSTALLATION INSTRUCTIONS
Please retain this owner’s manual for
future reference.
Read and follow all safety rules and
instructions before using this product.
GUIDE DE L' UTILISATEUR ET
INSTRUCTIONS D' INSTALLATION
Veuillez conserver ce manuel de
l’utilisateur pour référence future.
Lisez et suivez toutes les règles et les
instructions relatives à la sécurité avant
d’utiliser ce produit.
Model/Modèle
CLIMATISEUR
MOBILE
EnglishFrançais
To contact Goldstar, 24 hours a day,
7daysaweek:
1-800-243-0000 (US)
1-888-542-2623 (Canada)
Or visit us on the Web at:
Pour contacter Goldstar,24 heures
par jour, 7 jours par semaine, appelez le :
1-800-243-0000 (US)
1-888-542-2623 (Canada)
ou visitez-nous sur le Web à l’adresse :
www.goldstarappliances.com
www.goldstarappliances.com
GP120CE
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
3
English
WARNING This symbol indicates the possibility of death or serious injury.
CAUTION This symbol indicates the possibility of injury or damage to property.
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and
obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “WARNING” or “CAUTION”.
These words mean:
WARNING To reduce the risk of fire, electric shock, or injury
to persons when using this appliance, follow basic precautions, including the following:
Do not attempt to repair or replace any part
of your air conditioner unless it is specifically
recommended in this manual. All other services
should be referred to a qualified technician.
If the power cord becomes worn or damaged,
the cord should only be replaced by a qualified
service technician using genuine replacement
parts.
The air conditioner should be plugged into its
own grounded 15A, 60 Hz., 120 VAC circuit.
Do not plug other appliances into the same
outlet; it can overload the circuit and cause a fire
or electric shock.
Do not remove the round grounding prong from
the plug. It can result in the risk of electric shock.
This air conditioner is not designed for use by
young children. Young children should be
supervised to ensure that they do not play with
or climb on the air conditioner.
Be sure all packaging materials are removed
from the air conditioner before use. It can result
in personal injury.
Do not disassemble or modify the air conditioner
or the power cord. It can result in the risk of
electric shock or fire.
Do not place the power cord or air conditioner
near a heater, radiator, or other heat source. It
can result in the risk of electric shock or fire.
Do not use this or any appliance near flammable
gases or liquids or other combustibles, such as
gasoline, benzene, thinner, etc. It can result in
the risk of electric shock or fire.
Make sure the power cord is plugged firmly and
completely into the outlet. It can result in the risk
of electric shock or fire.
Do not start or stop operation by plugging in or
unplugging the power cord. It can result in the
risk of electric shock.
If the air conditioner is making unusual sounds or
is emitting smoke or an unusual odor, unplug it
immediately. It can result in the risk of electric
shock or fire.
Do not use if the electrical socket is loose or
damaged. It can result in the risk of electric
shock or fire.
Do not operate with wet hands or in a damp
environment. It can result in the risk of electric
shock.
Do not use this or any electrical appliance if you
smell gas. It can result in the risk of fire or
explosion.
Turn off and unplug the air conditioner before
cleaning to avoid the risk of electric shock.
Do not clean the unit with water. Water can enter
the unit and damage the insulation, creating a
shock hazard. If water enters the unit, unplug it
immediately and contact Customer Service. It
can result in the risk of electric shock.
Use two or more people to lift and install the
unit. Failure to do so can cause back injury or
other injuries.
BASIC SAFETY PRECAUTIONS
4
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
To avoid possible cuts, avoid contacting the
metal parts of the air conditioner when removing
or reinstalling the filter. It can result in the risk of
personal injury.
Do not block the air inlet or outlet of the air
conditioner. Reduced air flow will result in poor
performance and could damage the unit.
Always grasp the plug when plugging in or
unplugging the air conditioner. Never unplug by
pulling on the cord. It can result in result in the
risk of electrical shock and damage.
Always turn off and unplug the air conditioner
when it will not be used for extended period of
time. This conserves energy and reduces the
chance of accidents.
Secure the wheels with blocks to prevent the air
conditioner from rolling on smooth floors.
Install the air conditioner on a sturdy, level floor
capable of supporting up to 110 lbs (50 kg).
Installation on a weak or unlevel floor can result
in result in the risk of property damage and
personal injury.
Make sure the air conditioner is the correct size
for the area you wish to cool. Using an air
conditioner that is the wrong size can waste
energy and damage the air conditioner.
Close all doors and windows to the room for
most efficient operation.
To prevent damage to the surface finish, use only
a soft cloth to clean the air conditioner. Do not
use wax, thinner, or a strong detergent.
To prevent spills and property damage, be sure
to drain the air conditioner properly.
To prevent the coils from freezing, do not operate
the air conditioner if the room temperature is
below 18°C (65°F).
Do not position the air conditioner so that
pets or house plants are exposed to the
direct air flow. It can result in the risk of injury
to pets or house plants.
This air conditioner is designed for normal
household use. Do not use for cooling pets,
foods, precision machinery, or art objects.
Do not drink the water from the drain pan.
Dispose of it properly outdoors or down
the drain.
Do not operate air conditioner without the filter
securely in place. Operation without the filter
could damage the unit.
Clean the filter every two weeks, or more often
if needed.
BASIC SAFETY PRECAUTIONS
CAUTION To reduce the risk of fire, electric shock, or injury to persons when
using this appliance, follow basic precautions, including the following:
ELECTRICAL SAFETY
WARNING
Electrical Shock Hazard
Failure to follow these instructions can result
in death, fire, or electrical shock.
This unit must be properly grounded.
Do not, under any circumstances, cut or
remove the ground prong.
If you do not have a properly grounded
outlet, or if there is any doubt that the outlet
is not properly grounded, a qualified
electrician should check the outlet and
circuit, and, if necessary, install a properly
grounded outlet.
This air conditioner must be plugged
into a grounded 60 Hz, 120 VAC outlet
protected by a 15 amp time delay fuse
or circuit breaker.
This air conditioner must be installed in
accordance with national wiring codes.
Do not alter or modify the plug or cord
of this air conditioner. If the power cord
becomes worn or damaged, the cord should
only be replaced by a qualified service
technician using genuine replacement parts.
Do not use an extension cord.
6
^
1
2
3
9
5
7
8
SWIVELING CASTERS
FILTER
UPPER DRAIN PORT
9
Check all the accessories included in the package and
please refer to the installation instructions for their usage.
KEY PART AND COMPONTS
CONTROL PANEL AND DISPLAY
AIR DISCHARGE
INTEGRATED HANDLES
6
BOTTOM DRAIN PORT
FLEXIBLE VENTING HOSE
4
INFRARED REMOTE CONTROL
Easy-to-read digital display shows the set temperature and
indicator lights show the operating mode. Simple push buttons
make changing settings quick and easy.
Integrated handles provide a convenient grip when lifting the
air conditioner.
The remote control allows you to adjust the temperature and
operate most functions of the air conditioner from across the
room.
Swiveling casters allow you to move the air conditioner easily
on most floor surfaces.
Used when water is full or free of using long time.
Before moving the unit, drain the internal water collection tank
completely by using bottom drain port.
Filter cover clips in place for easy access to the air filter.
Used when Continuous Drainage or in dry mode.
Use the diffuser and hose to connect the air conditioner to the
window installation kit to vent exhaust air outside.
Distribute air more evenly through the room.
1
2
3
5 6
7
8
4
PARTS AND FEATURES
English
7
1
2
4
5
1
2
3
4 5
6
1
1
8
Press these buttons to set room temperature
or time when in Time On/Off mode.
6
Display different signals accordingly.
7
AUTO SWING
8
CELSIUS AND FAHRENHEIT EXCHANGE BUTTON
To vary from Fahrenheit to Celsius, press both UP and DOWN button
3
CONTROL PANEL AND REMOTE
Operation of functions is the same when using the remote or the control panel,
unless otherwise stated.
POWER
Operation begins when this button is pressed and stops
when you press the button again
MODE
Press this button to select COOL, DRY, FAN mode
FAN SPEED
Adjusts the circulation fan speed between HIGH,
MID, LOW fan speed.
TIMER
Press this button to set TIMER ON, TIMER OFF
or NO TIME
UP & DOWN
LCD Display
This button can automatically control
the air flow direction
NOTE
1
8
3
5
2
4
7
8
1
PARTS AND FEATURES
Refer to the Installation Instructions included in
this manual before using the air conditioner.
Once the air conditioner has been properly
assembled and installed:
Plug the power cord into its own dedicated
properly grounded outlet.
Do not plug ot
her appliances
into the same outlet;
it could overload the outlet and create a
e hazard.
Make sure the air conditioner and cord is
positioned where it does not create a
tripping hazard and will receive adequate
ventilation. Do not place it directly next to
furniture or objects that could block the
vent openings.
Make sure that any items that could be
blown over or damaged by the airflow from
the fan are out of the airflow path.
B
PREPARING FOR OPERATION
1
2
Refer to the Installation Instructions included in
this manual before using the air conditioner.
Once the air conditioner has been properly
assembled and installed:
co into own dedicate
r rly grounded outlet.
onotplugot
liances
into the same outlet;
it could overload the outlet and c a
fir
e
Make sure the air conditioner and cord is
positioned where it does not create a
tripping hazard and will receive adequate
ventilation. Do not place it directly next to
furniture or objects that could block the
vent openings.
Make sure that any items that could be
blown over or damaged by the airflow from
are out of the path.
BEFORE USING YOUR AIR CONDITIONER
3
Do not remain in the direct airflow from the air
conditioner for extended periods of time.
To prevent damage or injury to pets and
plants, make sure they are not exposed to
direct airflow from the air conditioner.
When used at the same time as stoves,
fireplaces, and other combustion devices,
make sure there is a sufficient flow of fresh air
into the room. Do not use in tightly enclosed
spaces with these types of devices.
This air conditioner is intended for household
use as a consumer comfort appliance. Do not
use it as a precision climate control system,
or for purposes such as cooling precision
equipment, food, pets, plants, artwork, etc.
Such items could be damaged.
Do not bend the hose downward when
window installation kit is not applied. It may
cause failure of air conditioner or performance
deterioration.
IMPORTANT:
Remove and store packing materials for reuse.
Remove any shipping tape before using the
air conditioner. If the tape leaves behind any
adhesive, rub a small amount of liquid dish
soap onto it and wipe with a damp cloth. Do
NOT use sharp instruments, alcohol, thinners,
or abrasive cleaners to remove adhesive.
They could damage the finish.
UNPACKING THE AIR CONDITIONER
HOW TO USE
English
Be sure to note
proper polarity!
1
2
3
BEFORE USING YOUR AIR CONDITIONER
INSERTING BATTERIES IN THE REMOTE
Before using your remote, install the provided
AAA batteies :
STORAGING REMOTE CONTROL
1
2
Press in the locking tab on the battery cover
on the back of the remote and remove the
cover
Insert two new alkaline AAA batteries into
the battery compartment, being sure to note
the proper polarity.
Reattach the battery cover, making sure the
locking tab clicks into place.
NOTE :
Use only alkaline batteries. Do not use
rechargeable batteries.
When replacing batteries, always replace both
batteries with new batteries. Do not mix old
and new batteries.
If the air conditioner will not be used for an
extended period of time, remove the batteries
from the remote.
Lift up the Control Panel.
Slide the Remote into place for storage.
1
2
Remote
Control
Control Panel
CAUTION
噝
If the liquid from the batteries
gets onto
Do not use the remote if the
batteries have
噝If you eat the liquid from the
batteries,
The chemicals in batteries could
cause bur
your skin or clothes, wash it well with clean water.
leaked.
brush your teeth and see doctor.
ns or other health hazards.
1
1
8
HOW TO USE
INSTALLATION INSTRUCTIONS
50cm
50cm
English
11
The length of the exhaust pipe is specially designed according to the specification of this product.
Do not replace or prolong it with your own private hose as this could cause mal-function.
WARNING
1
2
SELECTION OF INSTALLATION LOCATION
Install the unit on a flat and dry place.
For best performance,allow at least 50cm
of air space on all sides of the unit for
good air circulation.
English
INSTALLATION INSTRUCTIONS
PREPARING FOR INSTALLATION
WARNING The air conditioner is heavy! Use two or more people to
lift and install the unit! Failure to do so could result in back injury or other injuries.
The following components are used for window venting.
Not all components are used for every installation.
EXHAUST COMPONENTS
13
4 Type A Screws
10 Type B Screws
Security Bracket
1 Type B Foam Seal
(non-adhesive)
2 Type C Foam Seals
(Adhesive type-Shorter)
Flexible Venting Hose
Window Installation Kit
(includes 2 Window Vent
Panel and 2 Extension
Panels)
2 Type A Foam Seals
(adhesive)
Vent Panel
Small
Extension
Panel
Large
Extension
Panel
Extension
Vent Panel
INSTALLATION INSTRUCTIONS
WINDOW VENT PANEL AND EXTENSIONS
14
Small
extension
panel
Vent
Panel
The window installation kit allows you to install the air conditioner in most vertical-sliding windows
457mm to 1219mm wide, or casement-style windows from 457mm to 1219mm high.
For an 457mm window opening, use the
window vent panel by itself.
For window openings from 464mm to 610mm
use the window vent panel and the small
extension panel.
For window openings from 610mm to 737mm
use the window vent panel and the large
extension panel.
For window openings from 737mm to 914mm
use the window vent panel and both extension
panels.
Vent
Panel
457mm
457mm
Vent
Panel
464mm - 610mm
Small extension
panel
Vent
Panel
Large
extension
panel
Vent
Panel
Large extension
panel
Vent
Panel
610mm - 737mm
Large
extension
panel
Vent
Panel
737mm -914mm
Large extension
panel
Vent
Panel
Small
extension
panel
Small
extension
panel
464mm - 610mm
610mm - 737mm
737mm -914mm
For window openings from 914mm to 1219mm
use both
vent panels and both extension panels.
Large
extension
panel
Vent
Panel
Large
extension
panel
Extension vent
panel
Extension vent
panel
Vent
Panel
í1219mm
Small
extension
panel
Small
extension
panel
914mm
í1219mm
914mm
Foam seal A
(Adhesive type)
Foam seal C
(Adhesive type-shorter)
2
Insert the vent panel assembly, including
extension panels, if needed, into the window
opening.
Extend the
extension panels, if used.
Foam seal B
(Non-adhesive type)
Vent
Panel
3
Carefully lower the window. Secure the vent
panel in place with 4 type B screws, plus
one screw for each extension:
Vent panel only: 4 type B screws
Vent panel and
one extension: 5 type B screws
Vent panel and
two extensions: 6 type B screws
Two ven t pa nels and
two extensions: 9 type B screws
Type B screws
INSTALLATION IN VERTICAL SLIDING WINDOWSINSTALLATION IN VERTICAL SLIDING WINDOWS
INSTALLATION INSTRUCTIONS
English
4
Cut the foam seal B(Non-adhesive type) to
the window width. Stuff the foam seal B
between the glass and the window to
prevent air and insects from getting into the
room.
Extension panel
(if required)
NOTE: The window installation kit can be used with vertical sliding windows between 457mm
and 1219mm wide.
1
Cut the foam seal A(adhesive type) &
C(adhesive type-shorter) to the proper
length, and attach it to the window sash and
frame.
15
INSTALLATION IN VERTICAL SLIDING WINDOWS
5
Install the security bracket with a type B
screw, as shown.
Type B
screw
Security Bracket
INSTALLATION INSTRUCTIONS
16
6
Insert the oval end of the diffuser into the
window installation kit until the locking tabs
engage. Secure in place with four Type A
screws.
Type A screws
NOTE: The window installation kit can be used with casement windows between 457mm and
914mm tall.
Foam seal A
(Adhesive type)
Foam seal C
(Adhesive
type-shorter)
1
Cut the foam seal A(adhesive type) &
C(adhesive type-shorter) to the proper
length, and attach it to the window sash and
frame.
2
Insert the vent panel assembly, including
extension panels, if needed, into the window
opening.
Extend the extension panels, if used.
Foam seal B
(Non-adhesive type)
4
Cut the foam seal B(Non-adhesive type) to
the window height. Stuff the foam seal B
between the glass and the window to
prevent air and insects from getting into the
room.
3
Extension panel
(if required)
Vent
Panel
Type B screws
17
Carefully close the window. Secure the vent
panel in place with 4 type B screws, plus
one screw for each extension:
Vent panel only: 4 type B screws
Vent p anel and
one extension: 5 type B screws
Vent p anel and
two extensions: 6 type B screws
Two ven t pa nels and
two extensions: 9 type B screws
INSTALLATION IN CASEMENT STYLE WINDOWS
INSTALLATION INSTRUCTIONS
English
5
Install the window security bracket with a
type B screw, as shown.
Type B screw
Security
bracket
18
6
Insert the oval end of the diffuser into the
window installation kit until the locking tabs
engage. Secure in place with four of the
included screws.
Type A screws
Type B screw
INSTALLATION INSTRUCTIONS
INSTALLATION IN CASEMENT STYLE WINDOWS
CLEANING THE CASE
CLEANING THE AIR FILTER
Your air conditioner is designed for year-round
operation with only minimal ceaning and
maintenance
From maximum efficiency, it is recommended
that you have the cooling coils inspected and
cleaned annually. Your local Goldstar Authorized
Service Center can provide this inspection
and cleaning service for a nominal fee
Wipe the case with a
slightly damp cloth, then
wipe dry with a dry cloth
or towel.
Unplug the air conditioner before cleaning or performing any maintenace or serviceing.
Be careful when cleaning coils or removing or reinstalling the filter-the cooling fins
are shrp!
Failure to follow the above precautions could result in electrical shock or personal injury
WARNING
To prevent damage to the finishi, do not use
gasoline , benzene , thinner, etc., or any
abrasive cleansers to clean the air
conditioner; the may damage the finish.
Never pour water onto or into the unit; it
could damage internal components and
create a shock and fire hazard
The air filter should be cleaned every two weeks;
depending on indoor air quality, more frequent
cleaning may be needed. A dirty air filter will
decrease airflow and reduce efficiency
Do not operate the air conditioner without
the air filter in place
Open the air filter
cover upward
Take out the air filter
Use a vaccum cleaner to clean the filter. If
the filter is heavily soiled, it can be washed
in warm water using a mild detergent.
Do not use harsh cleaners or very hot
water. Do not wash in a dishwasher.
Allow the filter to dry completely before
reinstalling.
19
h
CARE AND CLEANING
h
CARE AND CLEANING
English
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Goldstar GP120CE Le manuel du propriétaire

Taper
Le manuel du propriétaire

dans d''autres langues