Regency Classic S2400 Le manuel du propriétaire

Catégorie
Cheminées
Taper
Le manuel du propriétaire

Ce manuel convient également à

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
919-542c
MODELS: F2400M S2400M
Classic™ F2400M / S2400M
Freestanding Woodstove
04.03.19
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Owners &
Installation Manual
Tested by:
F2400 Video
www.regency-re.com
French Manual: http://ow.ly/ZvmDk
Manuel en Français: http://ow.ly/ZvmDk
2 | Regency 2400 Freestanding Woodstove
|
2
Thank-you for purchasing a REGENCY FIREPLACE PRODUCT.
The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product
that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning.
“This wood heater has a manufacturer set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise
operate this wood heater in a manner inconsistent with operating instructions in this manual." Failure to follow the manual details can lead to smoke and CO
emissions spilling into the home. It is recommended to have monitors in areas that are expected to generate CO such as heater fuelling areas.
“U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2015 particulate emission standards using crib wood". Not approved for sale after
May 15, 2020.
Model Regency F2400 and S2400 – 3.4 g /hr.
SAFETY NOTE: If this woodstove is not properly installed, a house fire may result. For your safety, follow the installation instructions, contact local building,
fire officials, or authority having jurisdiction about restrictions and installation inspection requirements in your area.
The following statements are required by the Environmental Protection Agency:
“This manual describes the installation and operation of the Regency F2400 and S2400 wood heater. This heater meets the 2015 U.S. Environmental Pro-
tection Agency’s crib wood emission limits for wood heaters. Under specific test conditions this heater has been shown to deliver heat at rates ranging from
12,000 BTU/hr. to 36,800 BTU/hr.This unit has been tested using 5G series and generates the best efficiency when operated using well-seasoned wood and
installed in the main living areas where the majority of the chimney is within the building envelope and fully lined.
"It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual, or if any parts are removed.
It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual.
CAUTION: BURN UNTREATED WOOD ONLY. OTHER MATERIALS SUCH AS WOOD PRESERVATIVES, METAL FOILS, COAL,
PLASTIC, GARBAGE, SULPHUR OR OIL MAY DAMAGE THE HEATER
"This heater is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods, as
compared to softwoods or to green or freshly cut hardwoods."
DO NOT BURN:
Treated wood Lawn clippings or yard waste Manure or animal remains
• Coal Materials containing rubber including tires Saltwater driftwood or other previously salt water
saturated materials
• Garbage Materials containing plastic Unseasoned wood
• Cardboard Waste petroleum products , paints or paint thinners or asphalt products Paper products, cardboard, plywood or particle
board. The prohibition against burning these
materials does not prohibit the use of fire starters
made from paper, cardboard, saw dust, wax and
similar substances for the purpose of starting a
fire in a wood heater
• Solvents Materials containing asbestos
• Colored Paper Construction or demolition debris
Trash Railroad ties
Burning these materials may result in release of toxic fumes or render the heater ineffective and cause smoke.
The authority having jurisdiction (such as Municipal Building Department, Fire Department, Fire Prevention Bureau, etc.) should be consulted before instal-
lation to determine the need to obtain a permit.
This unit must be connected to either a listed factory built chimney suitable for use with solid fuels and conforming to ULC629 in Canada or UL-103HT in the
United States of America or code approved masonry chimney with flue liner.
F2400 and S2400 are tested and certified to ULC-S627-00 and UL1482-2011.
SAVE THESE INSTRUCTIONS
Regency 2400 Freestanding Woodstove | 3
3
|
Modular Parts
F2400 Video
ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY.
ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS.
4 | Regency 2400 Freestanding Woodstove
|
4
table of contents
Safety Label for F2400m ...............................................5
Safety Label for S2400M ...............................................6
F2400M Unit Dimensions ..............................................7
S2400M Unit Dimensions ..............................................8
Wood Stove Outside Air Dimensions .............................9
Residential Installation.................................................10
Modular Installation Options ........................................10
Room Air ..................................................................... 11
Important ..................................................................... 11
Minimum Clearance To Combustible Materials ........... 11
Stove Assembly Prior To Installation ...........................13
Step-by-step Chimney And Connector Installation ......14
Masonry Chimney........................................................15
Masonry Fireplace .......................................................15
Factory Built Chimney .................................................15
Combustible Wall Chimney
Connector Pass-throughs ............................................ 16
Recommended Heights For Woodstove Flue ..............17
Mobile Home Installation .............................................18
Listed Components For Mobile Home
Installation ...................................................................19
Flue Bae & Secondary Air Tube Installation .............19
Stainless steel smoke deector
adjustment / replacement ............................................20
Brick Installation ..........................................................21
Classic Door Handle .................................................... 21
Contemporary Door Handle.........................................21
Glass Installation .........................................................21
Step-by-step Optional Accessories Installation ...........21
Screen Door ................................................................22
Seasoned wood ........................................................... 23
Operating Instructions .................................................24
Draft Control ................................................................24
First Fire ......................................................................24
Fan Operation..............................................................25
Ash Disposal................................................................25
Safety Guidelines and Warnings .................................25
Maintenance ................................................................26
Creosote ......................................................................26
Maintenance Of Nickel-plated Doors ........................... 26
Latch Adjustment .........................................................26
Door Gasket ................................................................26
Glass Maintenance ...................................................... 26
Wood Storage ..............................................................26
F2400m Stove Main Assembly w/classic door ............27
F2400m Stove Main Assembly w/contemporary door .28
S2400m Step Stove Main Assembly w/classic door ....29
S2400m Step Stove Main Assembly
w/contemporary door ................................................... 30
Pedestal, Bottom Shield & Leg Options ......................31
Firebrick ....................................................................... 32
Warranty ......................................................................34
Regency 2400 Freestanding Woodstove | 5
5
|
safety decal
This is a copy of the label that accompanies each
Regency Freestanding Woodstove (F2400M).
We have printed a copy of the contents here
for your review.
NOTE: Regency units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
SAFETY LABEL FOR F2400M
Part #: 918-172f
Size: 6.53" H x 11.53" W (File at 100%)
Color: Everything printed black on grey except what is indicated is printed red on grey.
June 19/07: updated OMNI logo and standard as per SCC requirement.
Mar 1/10: Updated Omni Logo
Jan. 21/13: Updated yrs. of manufacture.
Feb. 17/14: Added French as per OMNI
May 06/15: Rev. E - Updated yrs. of manufacture/removed 1990 EPA info
Apr. 28/16: Rev. F - updated yrs of manufacture 2017-2021
MODEL: REGENCY MEDIUM FREESTANDING STOVE - F2400M
TESTED TO: UL-1482-2011 / ULC-S627-00 / UL-737-2011 REPORT NO:219-S-02-2
THE F2400M MEETS UL737 STANDARD FOR FIREPLACE STOVES WHEN A FIRESCREEN IS PROVIDED.
MINIMUM ALCOVE CEILING HEIGHT: 2.15 M / 7 FT MAXIMUM ALCOVE DEPTH 915 MM / 36 IN.
MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 455 MM / 18"
THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.
F2400M WITHOUT
AIRMATE SHIELD
F2400M WITH
AIRMATE SHIELD
K 405 mm / 16 in
L 150 mm / 6 in
M 150 mm / 6 in
FOR USE WITH SOLID WOOD FUEL ONLY. USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION. DO NOT OBSTRUCT COMBUSTION
AIR OPENINGS. OPERATE ONLY WITH FIREBRICKS IN PLACE. RISK OF SMOKE AND FLAME SPILLAGE, OPERATE ONLY WITH DOORS FULLY OPEN OR FULLY CLOSED.
IF INSTALLED IN A MOBILE HOME OPERATE ONLY WITH DOORS FULLY CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. WHEN OPERATED WITH DOORS OPEN THE
MANUFACTURER SUPPLIED SCREEN MUST BE USED. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE - IF HEATER
OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE
CREOSOTE BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH NEOCERAM
GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND SIDES AS INDICATED
OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.
OPTIONAL COMPONENT: FAN (846-515), ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS, SCREEN DOOR (846-101)
DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF APPLIANCE.
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH LISTED CHIMNEY SYSTEM: SECURITY MODEL
S2100, ICC EXCEL 2100, SELKIRK SENTINAL CF.
IN USA: LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA
VENT MODEL DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL. CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS
SECURITY MODEL S2100 OR MODEL ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR
METAL-FAB TEMP/GUARD, AMERI-TEC HS, ICC EXCEL 2100 . USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.
AUTEUR MINIMALE DU PLAFOND DE L’ALCÔVE : 2.15 M / 7 PL PROFONDEUR MAXIMALE DE L’ALCÔVE : 915 MM / 36 PO
DÉGAGEMENT MINIMAL DU PLAFOND POUR UN CONNECTEUR HORIZONTAL : 455 MM / 18 PO.
L’ESPACE AU-DESSOUS DU POÊLE NE DOIT PAS ÊTRE OBSTRUÉ. UTILISER SEULEMENT AVEC LES BRIQUES RÉFRACTAIRES EN PLACE.
POUR UTILISATION AVEC BOIS SOLIDE SEULEMENT. L’UTILISATION D’AUTRES COMBUSTIBLES PEUT ENDOMMAGER LE POÊLE ET CRÉER UNE CONDITION DANGEREUSE.
NE PAS OBSTRUER LES OUVERTURES D’AIR DE COMBUSTION. UTILISER SEULEMENT AVEC LA PORTE FERMÉE – OUVRIR LA PORTE DE CHARGEMENT POUR ALIMENTER
LE FEU SEULEMENT. NE PAS UTILISER DE GRILLE À BÛCHES NI SURÉLEVER LE FEU. MONTER LE FEU DE BOIS DIRECTEMENT SUR L’ÂTRE. NE PAS SURCHAUFFER – SI
LE POÊLE OU LE CONNECTEUR DE CHEMINÉE SE MET À ROUGIR, VOUS SURCHAUFFEZ. INSPECTEZ ET NETTOYEZ FRÉQUEMMENT LA CHEMINÉE ET LE CONNECTEUREN
CERTAINES CONDITIONS D’UTILISATION, UN DÉPÔT DE CRÉOSOTE PEUT SE FORMER RAPIDEMENT. GARDEZ LES MEUBLES ET AUTRES MATÉRIAUX COMBUSTIBLES
ÉLOIGNÉS DU POÊLE. REMPLACEZ LA VITRE SEULEMENT PAR DU VERRE EN NEOCERAM. LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR DES MATÉRIAUX NON
COMBUSTIBLES DÉPASSANT DU DESSOUS, DU DEVANT ET DES CÔTÉS DU POÊLE, TEL QU’INDIQUÉ, OU JUSQU’AU MATÉRIAU COMBUSTIBLE LE PLUS PRÈS PERMIS.
COMPOSANTS EN OPTION : VENTILATEUR (846-515), ALIMENTATION ÉLECTRIQUE : 115 VOLTS, 60 HZ, 2 AMP.
DANGER : RISQUE D’ÉLECTROCUTION. DÉCONNECTER L’ALIMENTATION ÉLECTRIQUE AVANT DE FAIRE L’ENTRETIEN DU POÊLE. NE PAS INSTALLER LE CORDON
ÉLECTRIQUE SOUS OU DEVANT L’APPAREIL.
COMPOSANTS EXIGÉS POUR INSTALLATION DANS UNE MAISON MOBILE : KIT DE PRISE D’AIR EXTÉRIEUR ET L’UN DES CONNECTEURS DE CHEMINÉE À DOUBLE PAROI
SUIVANTS :
AU CANADA : CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI : SECURITY MODÈLE DP, OU OLIVER MACLEOD PRO-VENT PV, AVEC SYSTÈME DE CHEMINÉE
HOMOLOGUÉ : SECURITY MODÈLE S2100, ICC EXCEL 2100, SUPER VENT 2100, SUPERPRO 2100, CF SENTINAL.
AUX ÉTATS-UNIS : CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI : SECURITY MODÈLE DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV,
SIMPSON DURA VENT MODÈLE DVL, GSW SUPER PIPE 6, METAL-FAB À DOUBLE PAROI. CONNECTÉ À L’UN DES SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS :
SECURITY MODÈLE S2100 OU MODÈLE ASHT, SELKIRK MODÈLE SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODÈLE SC OU METAL-FAB TEMP/
GUARD, AMERI-TECHS, ICC EXCEL 2100, SIMPSON DURA PLUS HTC. UTILISER LES COMPOSANTS DE CHEMINÉE SPÉCIFIÉS DANS LES INSTRUCTIONS D’INSTALLATION.
.
244
CAUTION
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.
ATTENTION
CHAUD DURANT LE FONCTIONNEMENT. NE TOUCHEZ PAS.
ÉLOIGNEZ LES ENFANTS, LES VÊTEMENTS ET LES MEUBLES.
LE CONTACT PEUT CAUSER DES BRÛLURES DE LA PEAU.
LISEZ LA PLAQUE SIGNALÉTIQUE ET LES INSTRUCTIONS
MADE IN CANADA / FAIT AU CANADA
MANUFACTURED BY/ FABRIQUÉ PAR:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC V4G 1H4
LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO
SUITABLE FOR MOBILE HOME INSTALLATION /
APPAREIL DE CHAUFFAGE AMBIANT HOMOLOGUÉ
À COMBUSTIBLE SOLIDE, CONVENANT AUSSI
POUR INSTALLATION DANS UNE MAISON MOBILE
FLOOR PROTECTION*
PROTECTION DE PLANCHER*
* Au Canada, la protection de plancher doit dépasser de
18 po (457 mm) à l’avant et de 8 po (200 mm) de chaque
côté du poêle et derrière le
poêle.
* In Canada, floor protection must extend 18" (450mm)
to the front and 8" (200mm) to each side and back of
the stove.
DO NOT REMOVE THIS LABEL/
NE RETIREZ PAS CETTE ÉTIQUETTE
244
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.
USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED UL103 HT
FACTORY-BUILT CHIMNEY SUITABLE FOR USE WITH SOLID FUELS OR MASONRY CHIMNEY.
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A
CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY CONNECTOR THROUGH COMBUSTIBLE
WALL OR CEILING. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
INSTALLER ET UTILISER SEULEMENT SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION DU FABRICANT.
CONTACTER LES RESPONSABLES DU BÂTIMENT OU DU SERVICE-INCENDIE DE VOTRE RÉGION POUR CONNAÎTRE
LES RESTRICTIONS ET EXIGENCES D’INSPECTION DANS VOTRE RÉGION. UTILISER UN CONNECTEUR D’UN DIAMÈTRE
MINIMAL DE 150 MM (6 PO) 24 MSG EN ACIER NOIR OU 26 MSG EN ACIER BRONZÉ AVEC CHEMINÉE PRÉFABRIQUÉE
HOMOLOGUÉE UL103 HT CONÇUE POUR UTILISATION AVEC COMBUSTIBLES SOLIDES OU UNE CHEMINÉE DE MAÇON-
NERIE.
VOIR LE CODE DU BÂTIMENT LOCAL ET LES INSTRUCTIONS DU FABRICANT CONCERNANT LES PRÉCAUTIONS
EXIGÉES POUR INSTALLER UNE CHEMINÉE TRAVERSANT UN MUR OU PLAFOND EN MATÉRIAUX COMBUSTIBLES.
NE FAITES PAS TRAVERSER LE CONNECTEUR DE CHEMINÉE DANS UN MUR OU PLAFOND EN MATÉRIAUX COMBUS-
TIBLES. NE RACCORDEZ PAS CE POÊLE À BOIS À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE APPAREIL.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
DÉGAGEMENTS MINIMUMS AUX MATÉRIAUX COMBUSTIBLES
F2400M WITH AIRMATE SHIELD F2400M WITHOUT AIRMATE SHIELD
RESIDENTIAL INSTALLATION USING
SINGLE WALL CONNECTOR
MEASURE FLUE
FROM HEATER CENTER-LINE
RESIDENTIAL INSTALLATION USING
SINGLE WALL CONNECTOR
SIDEWALL A 457 mm / 18 in D 762 mm / 30 in
BACKWALL B 305 mm / 12 in E 470 mm / 18.5 in
CORNER C 165 mm / 6.5 in F 457 mm / 18 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - MOBILE HOME
SIDEWALL A 380 mm / 15 in D 685 mm / 27 in
BACKWALL B 165 mm / 6.5 in E 330 mm / 13 in
CORNER C 152 mm / 6 in F 444 mm / 17.5in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
SIDEWALL A 380 mm / 15 in D 685 mm / 27 in
BACKWALL B 165 mm / 6.5in E 330 mm / 13 in
CORNER C 152 mm / 6 in F 444 mm / 17.5 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - ALCOVE
SIDEWALL A 406 mm / 16 in D 711 mm / 28 in
BACKWALL B 280 mm / 11 in E 444 mm / 17.5 in
CORNER C 152 mm / 6 in F 444 mm / 17.5 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - MOBILE HOME
SIDEWALL A 380 mm / 15 in D 685 mm / 27 in
BACKWALL B 140 mm / 5.5 in E 304 mm / 12 in
CORNER C 102 mm / 4 in F 393 mm / 15.5 in
SIDEWALL A 380 mm / 15 in D 685 mm / 27 in
BACKWALL B 140 mm / 5.5 in E 304 mm / 12 in
CORNER C 102 mm / 4 in F 393 mm / 15.5 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - ALCOVE
SIDEWALL G 380 mm / 15 in I 685 mm / 27 in
BACKWALL H 165 mm / 6.5 in J 330 mm / 13 in
MEASURE FLUE
FROM HEATER CENTER-LINE
SIDEWALL G 380 mm / 15 in I 685 mm / 27 in
BACKWALL H 140 mm / 5.5in J 304 mm / 12 in
918-172f
JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV DEC
DATE OF MANUFACTURE
2017 2019
2020
2021
2018
6 | Regency 2400 Freestanding Woodstove
|
6
safety decal
This is a copy of the label that accompanies
each Regency Medium Freestanding Step
Stove (S2400M). We have printed a copy of the
contents here for your review.
NOTE: Regency units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
SAFETY LABEL FOR S2400M
MODEL: REGENCY MEDIUM FREESTANDING STEP STOVE - S2400M
TESTED TO: UL-1482-2011 / ULC-S627-00 / UL-737-2011 REPORT NO:219-S-02-2
THE S2400M MEETS UL737 STANDARD FOR FIREPLACE STOVES WHEN A FIRESCREEN IS PROVIDED.
S2400M
K 405 mm / 16 in
L 150 mm / 6 in
M 150 mm / 6 in
MINIMUM ALCOVE CEILING HEIGHT: 2.15 M / 7 FT MAXIMUM ALCOVE DEPTH 915 MM / 36 IN.
MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 455 MM / 18"
THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.
FOR USE WITH SOLID WOOD FUEL ONLY. USE OF OTHER FUELS MAY DAMAGE HEAT ER AND CREATE A HAZARDOUS CONDITION. DO NOT OBSTRUCT COMBUSTION
AIR OPENINGS. OPERATE ONLY WITH FIREBRICKS IN PLACE. RISK OF SMOKE AND FLAME SPILLAGE, OPERATE ONLY WITH DOORS FULLY OPEN OR FULLY CLOSED.
IF INSTALLED IN A MOBILE HOME OPERAT E ONLY WITH DOORS FULLY CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. WHEN OPERAT ED WITH DOORS OPEN THE
MANUFACTURER SUPPLIED SCREEN MUST BE USED. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE - IF HEATER
OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE
CREOSOTE BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH NEOCERAM
GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND SIDES AS INDICATED
OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.
OPTIONAL COMPONENT: FAN (846-515), ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS, SCREEN DOOR (846-101)
DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF APPLIANCE.
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH LISTED CHIMNEY SYSTEM: SECURITY MODEL
S2100, ICC EXCEL 2100, SELKIRK SENTINAL CF.
IN USA: LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA
VENT MODEL DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL. CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS
SECURITY MODEL S 2100 OR MODEL ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR
METAL-FAB T EMP/GUARD, AMERI-TEC HS, ICC EXCEL 2100 . U SE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.
AUTEUR MINIMALE DU PLAFOND DE L’ALCÔVE : 2.15 M / 7 PL PROFONDEUR MAXIMALE DE L’ALCÔVE : 915 MM / 36 PO
DÉGAGEMENT MINIMAL DU PLAFOND POUR UN CONNECTEUR HORIZONTAL : 455 MM / 18 PO.
L’ESPACE AU-DESSOUS DU POÊLE NE DOIT
PAS ÊTRE OBSTRUÉ. UTILISER SEULEMENT AVEC LES BRIQUES RÉFRACTAIRES EN PLACE.
POUR UTILISATION AVEC BOIS SOLIDE SEULEMENT. L’UTILISATION D’AUTRES COMBUSTIBLES PEUT ENDOMMAGER LE POÊLE ET CRÉER UNE CONDITION DANGEREUSE.
NE PAS OBSTRUER LES OUVERTURES D’AIR DE COMBUSTION. UTILISER SEULEMENT AVEC LA PORTE FERMÉE – OUVRIR LA PORTE DE CHARGEMENT POUR ALIMENTER
LE FEU SEULEMENT. NE PAS UTILISER DE GRILLE À BÛCHES NI SURÉLEVER LE FEU. MONTER LE FEU DE BOIS DIRECTEMENT SUR L’ÂTRE. NE PAS SURCHAUFFER – SI
LE POÊLE OU LE CONNECTEUR DE CHEMINÉE SE MET À ROUGIR, VOUS SURCHAUFFEZ. INSPECTEZ ET NETTOYEZ FRÉQUEMMENT LA CHEMINÉE ET LE CONNECTEUREN
CERTAINES CONDITIONS D’UTILISATION, UN DÉPÔT DE CRÉOSOTE PEUT SE FORMER RAPIDEMENT. GARDEZ LES MEUBLES ET AUTRES MATÉRIAUX COMBUSTIBLES
ÉLOIGNÉS DU POÊLE. REMPLACEZ LA VITRE SEULEMENT PAR DU VERRE EN NEOCERAM. LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR DES MATÉRIAUX NON
COMBUSTIBLES DÉPASSANT DU DESSOUS, DU DEVANT ET DES CÔTÉS DU POÊLE, TEL QU’INDIQUÉ, OU JUSQU’AU MATÉRIAU COMBUSTIBLE LE PLUS PRÈS PERMIS.
COMPOSANTS EN OPTION : VENTILATEUR (846-515), ALIMENTATION ÉLECTRIQUE : 115 VOLT S, 60 HZ, 2 AMP.
DANGER : RISQUE D’ÉLECTROCUTION. DÉCONNECTER L’ALIMENTATION ÉLECTRIQUE AVANT DE FAIRE L’ENTRETIEN DU POÊLE. NE PA S INSTALLER LE CORDON
ÉLECTRIQUE SOUS OU DEVANT L’APPAREIL.
COMPOSANTS EXIGÉS POUR INSTALLATION DANS UNE MAISON MOBILE : KIT DE PRISE D’AIR EXTÉRIEUR ET L’UN DES CONNECTEURS DE CHEMINÉE À DOUBLE PAROI
SUIVANTS :
AU CANADA : CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI : SECURITY MODÈLE DP, OU OLIVER MACLEOD PRO-VENT PV, AVEC SYSTÈME DE CHEMINÉE
HOMOLOGUÉ : SECURITY MODÈLE S2100, ICC EXCEL 2100, SUPER VENT 2100, SUPERPRO 2100, CF SENTINAL.
AUX ÉTATS-UNIS : CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI : SECURITY MODÈLE DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV,
SIMPSON DURA VENT MODÈLE DVL, GSW SUPER PIPE 6, METAL-FAB À DOUBLE PAROI. CONNECTÉ À L’UN DES SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS :
SECURITY MODÈLE S2100 OU MODÈLE ASHT, SELKIRK MODÈLE SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODÈLE SC OU METAL-FAB TEMP/
GUARD, AMERI-TECHS, ICC EXCEL 2100, SIMPSON DURA PLUS HTC. UTILISER LES COMPOSANTS DE CHEMINÉE SPÉCIFIÉS DANS LES INSTRUCTIONS D’INSTALLATION.
.
245
CAUTION
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.
ATTENTION
CHAUD DURANT LE FONCTIONNEMENT. NE TOUCHEZ PAS.
ÉLOIGNEZ LES ENFANTS, LES VÊTEMENTS ET LES MEUBLES.
LE CONTACT PEUT CAUSER DES BRÛLURES DE LA PEAU.
LISEZ LA PLAQUE SIGNALÉTIQUE ET LES INSTRUCTIONS
MADE IN CANADA / FAIT AU CANADA
MANUFACTURED BY/ FABRIQUÉ PAR:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC V4G 1H4
LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO
SUITABLE FOR MOBILE HOME INSTALLATION /
APPAREIL DE CHAUFFAGE AMBIANT HOMOLOGUÉ
À COMBUSTIBLE SOLIDE, CONVENANT AUSSI
POUR INSTALLATION DANS UNE MAISON MOBILE
FLOOR PROTECTION*
PROTECTION DE PLANCHER*
* In Canada, fl oor protection must extend 18" (450mm)
to the front and 8" (200mm) to each side and back of
the stove.
DO NOT REMOVE THIS LABEL/
NE RETIREZ PAS CETTE ÉTIQUETTE
245
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.
USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED UL103 HT
FACTORY-BUILT CHIMNEY SUITABLE FOR USE WITH SOLID FUELS OR MASONRY CHIMNEY.
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PA SSING A
CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY CONNECTOR THROUGH COMBUSTIBLE
WALL OR CEILING. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
INSTALLER ET UTILISER SEULEMENT SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION DU FABRICANT.
CONTACTER LES RESPONSABLES DU BÂTIMENT OU DU SERVICE-INCENDIE DE VOTRE RÉGION POUR CONNAÎTRE
LES RESTRICTIONS ET EXIGENCES D’INSPECTION DANS VOTRE RÉGION. UTILISER UN CONNECTEUR D’UN DIAMÈTRE
MINIMAL DE 150 MM (6 PO) 24 MSG EN ACIER NOIR OU 26 MSG EN ACIER BRONZÉ AVEC CHEMINÉE PRÉFABRIQUÉE
HOMOLOGUÉE UL103 HT CONÇUE POUR UTILISATION AVEC COMBUSTIBLES SOLIDES OU UNE CHEMINÉE DE MAÇON-
NERIE.
VOIR LE CODE DU BÂTIMENT LOCAL ET LES INSTRUCTIONS DU FABRICANT CONCERNANT LES PRÉCAUTIONS
EXIGÉES POUR INSTALLER UNE CHEMINÉE TRAVERSANT UN MUR OU PLAFOND EN MATÉRIAUX COMBUSTIBLES.
NE FAITES PAS TRAVERSER LE CONNECTEUR DE CHEMINÉE DANS UN MUR OU PLAFOND EN MATÉRIAUX COMBUS-
TIBLES. NE RACCORDEZ PAS CE POÊLE À BOIS À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE APPAREIL.
918-203f
JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV DEC
DATE OF MANUFACTURE
2017 2019 2020 20212018
S2400M MINIMUM CLEARANCES
TO COMBUSTIBLE MATERIALS
RESIDENTIAL INSTALLATION USING
SINGLE WALL CONNECTOR
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - ALCOVE
SIDEWALL A 406 mm / 16 in D 711 mm / 28 in
BACKWALL B 280 mm / 11 in E 444 mm / 17.5 in
CORNER C 152 mm / 6 in F 483 mm / 19 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - MOBILE HOME
SIDEWALL A 380 mm / 15 in D 685 mm / 27 in
BACKWALL B 140 mm / 5.5 in E 304 mm / 12 in
CORNER C 102 mm / 4 in F 432 mm / 17 in
SIDEWALL A 380 mm / 15 in D 685 mm / 27 in
BACKWALL B 140 mm / 5.5 in E 304 mm / 12 in
CORNER C 102 mm / 4 in F 432 mm / 17 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
MEASURE FLUE
FROM HEATER CENTER-LINE
SIDEWALL G 380 mm / 15 in I 685 mm / 27 in
BACKWALL H 140 mm / 5.5in J 304 mm / 12 in
DÉGAGEMENTS MINIMUMS AUX
MATÉRIAUX COMBUSTIBLES
INSTALLATION RÉSIDENTIELLE UTILISANT
UN CONNECTEUR À SIMPLE PAROI
MUR LATÉRAL
MUR ARRIÈRE
COIN
MUR LATÉRAL
MUR ARRIÈRE
COIN
MUR LATÉRAL
MUR ARRIÈRE
COIN
MUR LATÉRAL
MUR ARRIÈRE
A 406mm/16po
B 280mm/11po
C
152mm/6po
A 380mm/15po
B 140mm/5.5po
C 102mm/4po
A 380mm/15po
B 140mm/5.5po
C 102mm/4po
G 380mm/15po
H 140mm/5.5po
D 711mm/28po
E 444mm/17.5po
F 483mm/19po
D 685mm/27po
E 304mm/12po
F 432mm/17po
D 685mm/27po
E 304mm/12po
F 432mm/17po
I 685mm/27po
J 304mm/12po
INSTALLATION UTILISANT UN CONNECTEUR
HOMOLOGUÉ À DOUBLE PAROI - ALCÔVE
INSTALLATION UTILISANT UN CONNECTEUR
HOMOLOGUÉ À DOUBLE PAROI - MAISON MOBILE
INSTALLATION UTILISANT UN CONNECTEUR HOMOLOGUÉ
À DOUBLE PAROI - RÉSIDENTIELLE (DÉGAGEMENT
RÉDUIT
)
MESURER DU CENTRE DU
A PARTIR DU POÊLE CONDUIT DE FUMÉE
* Au Canada, la protection de plancher doit dépasser de
18 po (457 mm) à l’avant et de 8 po (200 mm) de chaque
côté du poêle et derrière le poêle.
Regency 2400 Freestanding Woodstove | 7
7
|
dimensions
F2400M UNIT DIMENSIONS
Classic DoorContemporary Door
33-7/16”
31-1/2”
7-3/4”
(197mm)
(799mm)
(848mm)
w/ Optional Legs
8 | Regency 2400 Freestanding Woodstove
|
8
dimensions
S2400M UNIT DIMENSIONS
Classic Door
Contemporary Door
7-3/4”
35-5/8”
33-5/8”
(197mm)
(905mm)
(854mm)
w/ Optional Legs
Regency 2400 Freestanding Woodstove | 9
9
|
dimensions
WOOD STOVE OUTSIDE AIR DIMENSIONS
With pedestal from base of unit to centerline
4-1/2" (114mm)
With bottom heat shield from rear heat shield to centerline
6-3/4"(171mm)
Rear
Front
Rear
10 | Regency 2400 Freestanding Woodstove
|
10
installation
RESIDENTIAL
INSTALLATION
1) Please read this entire manual before you install
and use your new woodstove. Failure to follow
instructions may result in property damage,
bodily injury or even death. Be aware that local
Codes and Regulations may override some
items in this manual. Check with your local
inspector.
2) Select a position for your Regency Stove.
Consult the minimum clearance chart for your
model and set the stove in place. For close
clearance installation use listed double wall
connector systems.
3) To insure vertical alignment, suspend a plumb
bob from the ceiling over the exact center of
your stove flue and mark a spot on the ceiling
to indicate the center of the chimney.
4) Check that the area above the ceiling is clear
for cutting. Re-confirm the clearance from the
stove to combustibles to insure that they are
within the prescribed limits.
5) This woodstove must be connected to a UL
103 HT (ULC S629) listed chimney or a code
approved masonry chimney with a flue liner.
6) Install chimney according to chimney manu-
facturers instructions. The performance of your
woodstove is governed to a very large part by
the chimney system. Too short a chimney can
cause difficult start-up, dirty glass, back smok-
ing when door is open, and even reduced heat
output.
Too tall a chimney may prompt excessive
draft which can result in very short burn
times and excessive heat output. The use
of an inexpensive flue pipe damper may be
helpful in reducing excessive draft.
CAUTION: The chimney should be the same
size as the 6" flue outlet on the stove. The
chimney must be listed as suitable for use
with solid fuels. For other types of chimneys
check with your local building code officials.
Do not confuse a chimney with a type “B”
Venting System used for gas appliances
as suitable for a wood burning appliance.
For Mobile Home installations refer to that
section within this manual.
7) Mark the location of the pedestal base or
legs on the floor, then move the stove aside
and mark the position of the floor protector.
8) The floor protector must be of non-combus-
tible material and must extend 16" (406mm)
in front of the door opening and 6" (152mm)
to the sides and rear of the unit. Some areas
may require a larger size floor protector.
See your local inspector. For outside air
installation refer to Mobile Home installation
instructions within this manual.
9) When the floor protection is complete, posi-
tion the stove with the flue collar centered
under the installed chimney.
10) In areas of seismic activity, Regency rec-
ommends that your unit is secured to the
floor by using the bolt down holes inside
the pedestal (the same ones used in Mobile
Home installations).
11) For residential installations using 6" "C"
Vent (single wall) the chimney connector
must be at least 24 gauge steel. Do not use
galvanized pipe. For Mobile Home installa-
tion refer to the Mobile Home installation
instructions within this manual.
12) Do not connect this unit to a chimney
serving another appliance.
13) A chimney connector cannot pass through
an attic or roof space, closet or similar
concealed space, or a floor, ceiling, wall
or partition of combustible construction.
In Canada, if passage through a wall, or
partition of combustible construction is
desired, the installation shall conform to
CAN/CSA-B365, Installation Code for Solid-
Fuel-Burning Appliances and Equipment.
14) Your Regency Woodstove is not to be con-
nected to any air distribution duct.
NOTE: In Canada, oor protection must
extend 18" (450mm) to the front
and 8" (200mm) to each side and
back of the stove.
MODULAR INSTALLATION OPTIONS
WARNING: ONLY USE SPECIFIED COMPONENTS.
The following items are required when assembling your Regency Stove. F2400 unit - the Rear Heat Deflector is supplied with the stove, but if you choose
not to use it you must use the Airmate instead.
Modular Part
Clearances are different. Generally you can get closer clearances with the airmate than with the rear heat deflector.
Airmate OR
Rear Heat Deflector
Convection heat with Airmate vs. Radiant Heat with Rear Heat Deflector. The Airmate pushes heat forward out into
the room, the Rear Heat Deflector deflects the heat upward. Refer to the Installation sections within this manual.
Pedestal or Legs
There are no performance differences with either the pedestal or legs. It is primarily a personal preference. Legs can
be either painted steel or painted cast.
Leg installation requires the bottom shield.
OPTIONS: These can be installed at time of installation or added later:
Blower/Fan
Adding the blower will increase the area heated by the stove, it can move warm air beyond the room where the stove
is located.
Ash Drawer Kit
Adding the Ash Drawer Kit makes cleaning ashes out of the stove easier and cleaner (refer to Bottom Shield Ash
Drawer Kit, Installation section).
Screen Door
A simple add-on option that will allow you to enjoy the sound, warmth and view of an open fire.
Regency 2400 Freestanding Woodstove | 11
11
|
installation
ROOM AIR
IMPORTANT
For installation using room air for combustion,
remove knockout from the pedestal, and/or from
the bottom if using a heat shield.
Mobile home installations require the use of
outside air.
On pedestal units there are two locations where
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Please read the section below carefully as clearances depend on whether the airmate or the
rear heat deflector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner,
and from the rear heat shield to a back wall.
Clearances may only be reduced by means approved by the regulatory authority.
outside air may be adapted to the unit. If using
the bottom of the pedestal, do not remove knock-
out from the rear of the pedestal. Only remove
rear knockout if outside air will be brought in
from the rear.
On leg units outside air can only be brought in
from the bottom of the heat shield.
Note: Once the knockout is removed there
are two tabs remaining. Bend both
tabs out for ease of installation when
attaching outside air.
NOTE: Be aware that local Codes and Regulations may override some clearances listed in this manual.
Check with your local inspector.
NOTE: This clearance is also required for air space between the apliance and wall/ceiling.
Residential Installation “C” Vent (Single Wall)
Unit From Unit From Corner From Flue Center-Line
A B C D E F
Medium F2400M with Airmate
16" (406 mm) 11" (280 mm) 6" (152 mm) 28" (710 mm) 17.5" (444 mm) 17.5" (444 mm)
with Rear Deector
18" (457 mm) 12" (304 mm) 6.5" (165 mm) 30" (762 mm) 18.5" (470 mm) 19.5" (495 mm)
Medium S2400M Step Stove
16" (406 mm) 11" (279 mm) 6" (152 mm) 28" (710 mm) 17.5" (432 mm) 19" (483 mm)
Residential Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling level.
Unit From Unit From Corner From Flue Center-Line
A B C D E F
Medium F2400M with Airmate
15" (381 mm) 5.5" (139 mm) 4" (101 mm) 27" (685 mm) 12" (304 mm) 15.5" (393 mm)
with Rear Deector
15" (381 mm) 6.5" (165 mm) 6" (152 mm) 27" (685 mm) 13" (330 mm) 17.5" (444 mm)
Medium S2400M Step Stove
15" (381 mm) 5.5" (139 mm) 4" (101 mm) 27" (685 mm) 12" (304 mm) 17" (432 mm)
Mobile Home Close Clearance (To be installed with required pipe components)
"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.)
Unit From Unit From Corner From Flue Center-Line
A B C D E F
Medium F2400M with Airmate
15" (381 mm) 5.5" (139 mm) 4" (101 mm) 27" (685 mm) 12" (304 mm) 15.5" (393 mm)
with Rear Deector
15" (381 mm) 6.5" (165 mm) 6" (152 mm) 27" (685 mm) 13" (330 mm) 17.5" (444 mm)
Medium S2400M Step Stove
15" (381 mm) 5.5" (139 mm) 4" (101 mm) 27" (685 mm) 12" (304 mm) 17" (432 mm)
12 | Regency 2400 Freestanding Woodstove
|
12
installation
Floor Protection
(Ember Protection only required)
A combustible floor must be protected by non-combustible
material (like tile, concrete board, or certified to UL-1618 or
as defined by local codes) extending beneath the heater and
a minimum of 6" (152mm) from each side and minimum 16"
(406mm) from the front face of the stove and minimum 6"
(or the rear clearance to combustibles whichever is smaller)
from the rear of the stove.
When installed with horizontal venting, non-combustible floor
protection must beneath the flue pipe and extend 2" (51mm)
beyond each side.
Minimum Overall Width (X) of Floor
Protector for all installations:
Stove F2400M 36" (914 mm)
Step Stove S2400M 36" (914 mm)
NOTE: In Canada, oor protection must extend 18" (450mm) to the
front and 8" (200mm) to each side and back of the stove.
Minimum Alcove Clearance and Clearance to Combustible Materials
The Regency Freestanding models have been alcove approved and must be installed
with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 84"
Maximum depth of alcove - 36"
NOTE: This clearance is also required for air space between the appliance and wall/ceiling.
Unit From Unit From Corner From Flue Center-Line
G H I J K L
Medium F2400M with Airmate
15" (381 mm) 5.5" (139 mm) 27" (685 mm) 12" (304 mm) 54" (1371 mm) 48" (1219 mm)
with Rear Deector
15" (381 mm) 6.5" (165 mm) 27" (685 mm) 13" (330 mm) 54" (1371 mm) 49" (1244 mm)
Medium S2400M Step Stove
15" (381 mm) 5.5" (139 mm) 27" (685 mm) 12" (304 mm) 54" (1371 mm) 48" (1219 mm)
Minimum Overall Depth (Y) of Floor Protector
Unit Residental `C`Vent Residential
Close Clearance
Mobile Home
Close Clearance
Alcove
Y Z Y Z Y Z Y
Z
Medium F2400M with Airmate
46" (1168 mm) 6" (152 mm) 45"* (1143 mm) 5" (127 mm) 45" (1143 mm) 5" (127 mm) 45"* (1143 mm) 5" (127 mm)
with Rear Deector
46" (1168 mm) 6" (152 mm) 45" (1143 mm) 5" (127 mm) 45" (1143 mm) 5" (127 mm) 45"* (1143 mm) 5" (127 mm)
Medium S2400M Step Stove
46" (1168 mm) 6" (152 mm) 45"* (1143 mm) 5" (127 mm) 45" (1143 mm) 5" (127 mm) 45"* (1143 mm) 5" (127 mm)
* The rear clearance to combustibles is less than 6" (for corner installations the rear corners may be angled to take advantage of the closer clearances).
Regency 2400 Freestanding Woodstove | 13
13
|
installation
Cover
Plate
Blanking
Plate
Pedestal
Washer
Bolt
Pedestal
Door
Cover
Plate
Diagram 2
Diagram 3
STOVE ASSEMBLY
PRIOR TO
INSTALLATION
All units require either the pedestal or 4 legs at-
tached to the base. The F2400M stove requires
either the Airmate or Rear Heat Deflector on top
of the stove. Clearances to combustible materials
vary depending on whether the airmate or rear
heat deflector is installed, so be sure to check
the Minimum Clearances, Installation section.
Airmate Assembly for F2400M
(850-105)
1) The airmate sits on top of the stove with
the slots in the sides fitting over the curved
deflector on the rear stove top. See diagram
1. Discard the Rear Heat Deflector that is
supplied with the unit, it is not required if the
airmate is installed.
2) Center the airmate and push it forward to the
front of the stove. The back of the airmate
should be level with the back and sides of
the rear heat shield. See Diagrams 2 & 3.
Rear Heat Deector
Assembly for F2400M
(815-555)
The rear heat deflector is supplied with the stove
and must be installed unless the optional airmate
has been selected. It stops the heat radiated
from the flue collar from overheating the rear
wall. The rear heat deflector is installed on top
of the rear heat shield, as shown in Diagram 4.
Side Shield Adjustment
The left and right side shields are lowered for
shipping and handling. It allows for a handhold
on the top of the stove. Before placing in the
Step Stove in its final position, the side shields
must be raised.
Loosen the screws on the rear on the stove (3
per side), slide the side panel up as far as pos-
sible and then secure by tightening the screws.
Pedestal Assembly
F2400M & S2400M
(020-925)
1) For easier assembly, tip the stove on its back
(onto a soft surface to prevent scratching).
Hint: If you have chosen the Ash Drawer
option, remove the ash dump cover plates
(knockout) before attaching the pedestal.
See page 17 "Ashdrawer Kit Installation".
2) Important: Remove the blanking plate if
a) you are not installing outside combustion
air or
b) outside air is to be brought in from the
rear of the stove (see below).
3) Unscrew the 4 bolts in the under-side of the
stove. Align the holes in the corners of the
pedestal top with the corresponding holes
in the base of the stove. Fasten using a bolt
and washer for each corner.
4) Push the
Regency logo
into the two
holes in the
front bottom
left corner of
the pedestal
cover plate.
Note: Any paint touch up should be done
prior to placing logo on pedestal.
5) If not using ash drawer, then cover plate must
be installed. If using ash drawer, then disregard
cover plate.
Side Shield
Diagram 1
Diagram 4
Shown with classic door
Shown with classic door
14 | Regency 2400 Freestanding Woodstove
|
14
installation
*
* when using single
wall pipe
Horizontal Installation
Standard Ceiling Installation
8) To complete your chimney installation, install
the double wall connector pipe from the
stove’s flue collar to the chimney support
device.
9) If you are using a horizontal connector,
the chimney connector should be as high
as possible while still maintaining the 18"
(457mm) minimum distance from the hori-
zontal connector to the ceiling.
10) NOTE: Residential Close Clearance and
Alcove installations require a listed dou-
ble wall connector from the stove collar
to the ceiling level.
The diagrams below illustrate one way to install
your unit into a standard ceiling or with a horizon-
tal connector. Check with your dealer or installer
for information on other options available to you.
STEP-BY-STEP
CHIMNEY AND
CONNECTOR
INSTALLATION
Note: These are a generic set of chimney in-
stallation instructions. Always follow
the manufacturers own instructions
explicitly. Verify the Minimum Recom-
mended Heights for Woodstove Flue
(Table 1 in the Installation section).
1) With your location already established, cut
and frame the roof hole. It is recommended
that no ceiling support member be cut for
chimney and support box installation. If it is
necessary to cut them, the members must
be made structurally sound.
2) Install radiant shield and support from above.
3) Stack the insulated pipe onto your finish
support to a minimum height of 3 feet above
the roof penetration, or 2 feet above any
point within 10 feet measured horizontally.
There must be at least 3 feet of chimney
above the roof level.
Note: Increasing the chimney height above
this minimum level will sometimes
help your unit to “breathe” better
by allowing a greater draft to be cre-
ated. This greater draft can decrease
problems such as, dicult start-ups,
back-smoking when door is open, and
dirty glass. It might be sucient to
initially try with the minimum required
height, and then if problems do arise
add additional height at a later date.
4) Slide the roof flashing over your chimney
and seal the flashing to the roof with roofing
compound. Secure the flashing to your roof
with nails or screws.
5) Place the storm collar over the flashing,
sealing the joints with a silicone caulking.
6) Fasten the raincap with spark screens (if
required) to the top of your chimney.
7) For optimum efficiency when installing into
a masonry chimney, size accordingly, i.e.
the 6" (152mm) flue dia. is 28.28 sq.in.
Leg and Bottom Shield Assembly
F2400M & S2400M
Bottom Shield 020-911
Legs (set of 4)
Cast - Painted Black 850-126
Cast - Brushed Nickel 850-128
The instructions below apply to the steel leg,
painted cast leg and the gold plated cast leg. It
will be easier to attach the legs to the stove if
the stove is tipped on its back (preferably on a
soft surface to prevent scratching). Ensure to be
extremely careful when tipping stove.
Important: Prior to installing the bottom hat
shield, remove the 4 inch blanking plate. See
below. This must be removed for combustion
air to enter the appliance.
1) Remove the 4 bolts from underside of the
base of the pedestal and discard. Also
remove cover plate and put to the side.
2) Line up the heat shield with the bottom of
the unit.
3) Start threading the bolt and washer (supplied
with the bottom shield) for about 1/4 of the
way through the leg with the washers being
underneath the legs. Ensure that the legs
are properly aligned with heat shield and
tighten the bolts.
4) Level the stove by adjusting the levelling
bolts in the bottom of each leg.
5) Reinstall cover plate.
6) Install logo plate onto heat shield by placing
in 2 holes as shown in diagram.
If you are installing outside combustion air, bend
the tabs out 90 degrees. Pipe fresh air into the
bottom shield by using a minimum 4" duct pipe
with a mesh grill at the outside termination. At-
tach the pipe to the 2 tabs with screws.
Bottom Shield
Cover
Plate
Tabs
Spacer
Leg
Leveling
Bolt
Washer
Logo
Plate
Bolt
Screw
Blanking Plate
Regency 2400 Freestanding Woodstove | 15
15
|
installation
FACTORY
BUILT CHIMNEY
When a metal prefabricated chimney is used, the manufacturer's installation instructions must be followed. You must also purchase and install the
ceiling support package or wall pass-through and "T" section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc.
Maintain proper clearance to the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other
obstructions for safety and proper draft operation.
MASONRY
CHIMNEY
Ensure that a masonry chimney meets the mini-
mum standards of the National Fire Protection
Association (NFPA) by having it inspected by
a professional. Make sure there are no cracks,
loose mortar or other signs of deterioration and
blockage. Have the chimney cleaned before the
stove is installed and operated. When connect-
ing the stove through a combustible wall to a
masonry chimney, special methods are needed.
MASONRY
FIREPLACE
There are listed kits available to connect a stove
to a masonry fireplace. The kit is an adapter
that is installed at the location of the fireplace
damper. The existing damper may have to be
removed to allow installation.
This unit is designed to use either a 5.5" (140mm)
or 6" (152mm) flue liner only within the confines
of the masonry chimney as shown.
Minimum 18" (457mm)
to centerline
Minimum
18"
(457mm
)
to
centerline
When referencing installation or connection to
masonry fireplaces or chimneys, the masonry
construction must or shall be code complying.
When referencing installation or connection to
masonry fireplaces or chimneys, the masonry
construction must or shall be code complying.
16 | Regency 2400 Freestanding Woodstove
|
16
installation
Method A: 12" (304.8 mm) Clearance to Combustible Wall
Member:
Using a minimum thickness 3.5" (89 mm) brick and a 5/8" (15.9 mm)
minimum wall thickness clay liner, construct a wall pass-through.
The clay liner must conform to ASTM C315 (Standard Specication
for Clay Fire Linings) or its equivalent. Keep a minimum of 12" (304.8
mm) of brick masonry between the clay liner and wall combustibles.
The clay liner shall run from the brick masonry outer surface to the
inner surface of the chimney ue liner but not past the inner surface.
Firmly grout or cement the clay liner in place to the chimney ue liner.
Method B: 9" (228.6 mm) Clearance to Combustible Wall Member:
Using a 6" (152.4 mm) inside diameter, listed, factory-built Solid-Pak
chimney section with insulation of 1" (25.4 mm) or more, build a wall
pass-through with a minimum 9" (228.6 mm) air space between the
outer wall of the chimney length and wall combustibles. Use sheet
metal supports fastened securely to wall surfaces on all sides, to
maintain the 9" (228.6 mm) air space. When fastening supports to
chimney length, do not penetrate the chimney liner (the inside wall
of the Solid-Pak chimney). The inner end of the Solid-Pak chimney
section shall be ush with the inside of the masonry chimney ue, and
sealed with a non-water soluble refractory cement. Use this cement
to also seal to the brick masonry penetration.
Minimum
12 in. (304.8mm)
to combustibles
Masonry chimney
Chimney Flue
Minimum chimney clearance to brick
and combustibles 2 in. (50.8mm)
Minimum clearance
12 in. (304.8mm)
of brick
Chimney
connector
Fire clay
liner
Method C: 6" (152.4 mm) Clearance to Combustible Wall Member:
Starting with a minimum 24 gage (.024" [.61 mm]) 6" (152.4 mm) metal
chimney connector, and a minimum 24 gage ventilated wall thimble
which has two air channels of 1" (25.4 mm) each, construct a wall
pass-through. There shall be a minimum 6" (152.4) mm separation area
containing berglass insulation, from the outer surface of the wall thimble
to wall combustibles. Support the wall thimble, and cover its opening
with a 24-gage minimum sheet metal support. Maintain the 6" (152.4
mm) space. There should also be a support sized to t and hold the
metal chimney connector. See that the supports are fastened securely
to wall surfaces on all sides. Make sure fasteners used to secure the
metal chimney connector do not penetrate chimney ue liner.
Method D: 2" (50.8 mm) Clearance to Combustible Wall Member:
Start with a solid-pak listed factory built chimney section at least
12" (304 mm) long, with insulation of 1" (25.4 mm) or more, and an
inside diameter of 8" (2 inches [51 mm] larger than the 6" [152.4
mm] chimney connector). Use this as a pass-through for a minimum
24-gage single wall steel chimney connector. Keep solid-pak section
concentric with and spaced 1" (25.4 mm) o the chimney connector
by way of sheet metal support plates at both ends of chimney section.
Cover opening with and support chimney section on both sides with
24 gage minimum sheet metal supports. See that the supports are
fastened securely to wall surfaces on all sides. Make sure fasteners
used to secure chimney ue liner.
COMBUSTIBLE WALL CHIMNEY
CONNECTOR PASS-THROUGHS
Regency 2400 Freestanding Woodstove | 17
17
|
installation
RECOMMENDED HEIGHTS FOR WOODSTOVE FLUE
Simple rules on draft (refer to Table 1).
1) At sea level minimum height is 12' straight.
2) Add the following vertical height to compen-
sate for:
45 deg. elbow = 1 ft.
90 deg. elbow = 2 ft.
"T" = 3 ft.
Each foot of horizontal run = 2 ft.
3) Add 4% overall for each 1000' above sea
level.
Example: a)
1-1/2 ft. of horizontal run = 3 ft.
one "T" = 3 ft.
Total Addition (at sea level) = 6 ft.
Example: b)
One 90 deg. elbow = 2 ft.
2 ft. of horizontal run = 4 ft.
one "T" = 3 ft.
Total Addition (at sea level) = 9 ft.
Recommended Flue Height
Elevation Example a) Example b)
0' 18' 21'
1000' 18.72' 21.84'
2000' 19.44' 22.68'
5000' 21.60' 25.20'
8000' 23.76' 27.72'
Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your chimney depends on the length of the chimney, local
geography, nearby obstructions and other factors. Too much draft may cause excessive temperatures in the appliance and may cause damage. An uncontrol-
lable burn or excessive temperature indicates excessive draft. Inadequate draft may cause back puffing into the room and plugging of the chimney. Inadequate
draft will cause the appliance to leak smoke into the room through appliance and chimney connector joints. Ensure the heater is installed in areas that are not
too close to neighbors or in valleys that would cause unhealthy air quality or nuisance conditions.
MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET
(Measured from the top of the unit)
ELEVATION (FT)
ABOVE SEA LEVEL
# OF ELBOWS
0 2 x 15
o
4 x 15
o
2 x 30
o
4 x 30
o
2 x 45
o
4 x 45
o
0-1000 12.0 13.0 14.0 15.0 18.0 16.0 20.0
1000-2000 12.5 13.5 14.5 15.5 19.0 16.5 21.0
2000-3000 13.0 14.0 15.0 16.0 19.5 17.0 21.5
3000-4000 13.5 14.5 15.5 17.0 20.0 18.0 22.5
4000-5000 14.0 15.0 16.0 17.5 21.0 18.5 23.0
5000-6000 14.5 15.5 17.0 18.0 21.5 19.0 24.0
6000-7000 15.0 16.0 17.5 18.5 22.5 20.0 25.0
7000-8000 15.5 16.5 18.0 19.0 23.0 20.5 25.5
8000-9000 16.0 17.0 18.5 20.0 24.0 21.0 26.5
9000-10000 16.5 17.5 19.0 20.5 24.5 22.0 27.0
NOTE: No more than two offsets (four elbows) allowed. Two 45
o
elbows equal one 90
o
elbow.
18 | Regency 2400 Freestanding Woodstove
|
18
installation
MOBILE HOME INSTALLATION
Once you have properly marked the position of
your unit and the floor protection as outlined in
the Residential Installation items #1 through #8,
a supply of fresh air has to be supplied to your
unit. Cut a minimum 4" (102mm) diameter hole
through your floor protector and the floor directly
under your pedestal base to the outside. Use 4"
(102mm) duct pipe with a mesh grill to pipe fresh
air into the pedestal area. Block off the hole in
the back of the pedestal with the square plate
and the two 1/2" screws provided.
Place your unit in position and secure it to the
floor using two lag bolts 3/8" (10mm) x 3-1/2"
(89mm) through the two holes inside the pedestal
base. It is important to maintain the structural
integrity of the Mobile Home floor, walls and roof
when installing your unit.
For Mobile Home units installed in the U.S. the
unit must be grounded using a #8 ground wire
with approved termination and star washer.
In addition to standard installation instructions the
following requirements are mandatory for installa-
tion in a mobile home.
1) The stove must be permanently bolted to
the floor of the Mobile Home using the floor
screws provided.
2) The stove must have a permanent outside air
source for combustion.
3) The stove must be electrically grounded to the
steel chassis of the Mobile Home.
4) A listed double-wall connector chimney system,
roof thimble, spark arrestor and roof flashing kit
suitable for use in Mobile Homes must be used.
5) If the chimney exits the Mobile Home at a loca-
tion other than through the roof, and exits at a
point 7ft. (2130mm) or less above the ground
level on which the Mobile Home is positioned
a guard or method of enclosing the chimney
shall be fitted at the point of exit for a height up
to 7ft. (2130mm).
6) The chimney shall be attached directly to the
room heater and shall extend at least 3 ft.
(914mm) above the part of the roof through
which it passes. The top of the chimney should
project at least 2ft. (610mm) above the highest
elevation of any part of the Mobile Home within
10 ft. (3048mm) of the chimney.
7) The chimney system shall comply with Local
Requirements.
8) Any openings in a chimney guard where required
must not permit the entrance of 3/4" (19mm)
diameter rod.
9) CAUTION: THE STRUCTURAL INTEGRITY OF
THE MOBILE HOME ROOF, FLOOR, WALLS
AND CEILING MUST BE MAINTAINED.
10) Check any other local building code as other
local codes may apply.
11) WARNING: DO NOT INSTALL IN A SLEEPING
ROOM OF A MOBILE HOME.
12) Use silicone to create an effective vapour
barrier at the location where the chimney or
other component penetrates to the exterior of
the structure.
CAUTION: At no time use unlabelled parts,
or substitute parts made for another chim-
ney system.
Install as per chimney manufacturer's
installation instructions.
WARNING: Operate only with door fully
closed - open feed door to feed fire only.
Regency 2400 Freestanding Woodstove | 19
19
|
installation
Slide the tube into the left hand side, as far
as possible and then bring it back into the
hole on the right hand side until it locks into
position. If the tube will not slide in easily,
simply use a pair of vise grips or pliers and
tap it into place with a hammer. A tighter fit
will ensure the tube will not move when the
unit is burning.
2) Slide the left baffle over the air tubes from
the front and then push it to the back.
SIMPSON DURA-PLUS
Qty.Part # Description
1 6DVL8693 Connector Kit
1 6DP-MH9096 Mobile Home Kit
ICC EXCEL 2100
Qty.Part # Description
1 6CL48 48" Chimney length (also in
12", 18", 24" lengths.)
1 6RC Rain Cap
1 6RCS Spark Screen (for rain cap)
1 6RDS/SQS Round/Square support box
1 6VF Flashing
1 6UBA "Ultrablack" Close Clearance
Connector
Canadian Installations*
SECURITY S2100 (see above for details)
ICC EXCEL 2100 (see above for details)
SELKIRK SENTINAL CF
*The use of alternate pitch flashings, support
box extensions, additional chimney lengths, and
additional chimney bracing, may be used on each
of the previously listed systems. These parts
though must be from the same system as listed,
and must be a similar and/or complimentary part.
CAUTION: At no time use unlabelled
parts, or substitute parts made for
another chimney system.
Install as per chimney manufacturer's instal-
lation instructions.
FLUE BAFFLE &
SECONDARY AIR TUBE
INSTALLATION
The flue baffle system located in the upper area
of the firebox is removable to make cleaning
your chimney system easier. The baffles must
be installed prior to your first fire. Smoke spill-
age and draft problems may occur if the
baffles are improperly positioned. Check
the position of the baffles on a regular basis as
they can be dislodged if too much fuel is forced
into the firebox.
Freestanding Stove
F2400M
The unit arrives with the 2 baffles on the floor
of the firebox.
1) If all 4 air tubes are installed continue on to
Step 2), if not, follow the instructions below.
Install the air tube into the holes in the side
channels. The notch goes on the right hand
side with the air holes facing toward the door.
LISTED COMPONENTS
FOR MOBILE HOME
INSTALLATION
The Regency F2400M and S2400M Freestand-
ing pedestal units are approved for installation
in a Mobile Home if one of the following pipe
systems is used.
U.S. Installation*
METALBESTOS SSII
Qty. Part # Description
1 6DS-VK Connector Kit
1 6TMH Shield/Support
1 6TAF-6 Flashing
1 6T-36 Chimney Length
1 6T-18 Chimney Length
1 6T-CT Rain Cap
PRO-JET 3103
Qty.Part # Description
1 PV06-TK Connector
1 CSB Shield/Support
1 RRS Radiation Shield
1 LFR03 Flashing
1 SL3 Chimney Length
1 SL1 Chimney Length
1 RCSA Rain Cap
SECURITY ASHT
Qty.Part # Description
1 DL42A-6 Connector Kit
1 6SS Shield/Support
1 6FAMH Flashing
1 6L3 Chimney Length
1 6L1 Chimney Length
1 CPE Rain Cap
SECURITY S2100
Qty.Part # Description
1 DL42A-6 Connector Kit
1 6XSF Support
1 6XFA Flashing
1 6XL3 Chimney Length
1 6XL18 Chimney Length
1 6XCPE Rain Cap
METAL-FAB TEMP/GUARD 2100
Qty.Part # Description
1 6DWBK Connector
1 6TGRS Roof Support
1 6TGG36 Chimney Length
1 6TGG12 Chimney Length
1 6TGF Flashing
1 6TGC Rain Cap
AMERI-TEC HS
Qty.Part # Description
1 6DCC Connector
1 6HSRS-12 Roof Support
(6PLRS-12-BK)
1 6F Flashing
1 6HS-36 Chimney Length
1 6HS-18 Chimney Length
1 6HS-RCS Rain Cap (6PL-MPC)
3) Tilt the left baffle up on top of the side chan-
nel and it will leave enough room to position
the right baffle in the same manner as Step
1) above. Then reposition the left baffle flat
on the air tubes.
4) Important: push both baffles so they are
tight against the side walls.
Note: When getting the chimney cleaned,
push the baes forward toward the
front of the stove, this should leave
sucient access to the ue. If it is
not enough space then remove the
middle air tube (reverse the procedure
in step 1) above), and bae and then
replace everything when cleaning is
completed.
Side View
Front View
Front View
20 | Regency 2400 Freestanding Woodstove
|
20
installation
STAINLESS STEEL SMOKE DEFLECTOR ADJUSTMENT / REPLACEMENT
The stainless smoke deflector is located in the upper front area of the firebox. The deflector is held in place with 2 bolts
Prior to the first fire, ensure deflector is seated properly and secured with 2 hand tightened bolts.
To replace the deflector, loosen off both bolts and slide defector upward and out. Install new defector and hand tighten bolts. Ensure positive location of the
deflector prior to hand tightening.
WARNING: Operation of the unit with out proper installation of smoke deflector will void warranty.
Smoke deector installed with 2 bolts.
Note: This is a view from the back of the unit
through the top.
Ensure defector is seated so bolts are situated
at the top of the keyhole before tightening.
Hand tighten bolts only.
Smoke deector
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Regency Classic S2400 Le manuel du propriétaire

Catégorie
Cheminées
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues